NOTES: THIS IS NOT A COLOUR PROOF . Refer to pantone chips and process match books for accurate colour samples. No trapping has been done to this file. Our artists have done everything possible to make this file mechanically perfect. However, before signing approval please check all copy, dimensions and colour space.
ArtWork Size: 100%
Docket Number:
Docket Name:
Stock:
Client:
Date (M/D/Y):
00412_LDG
OmniCure AC2 Series Brochure
Matte finish, text
Excelitas Technologies Corp.
Trim Size:
Bleed Size:
Colour Information
Printing inks: 4/4 colours
401-99 Spadina Avenue, Toronto, ON. CA M5V 3P8 • Tel. 416.850.9944 • Fax 647.342.9497
cmyk
Overall Satin AQ coating
Compact air-cooled UV LED design for ease of integration
Outstanding optical performance to provide maximum irradiance
Superior uniformity with the ability to adjoin multiple UV LED heads
Exceptional process control for repeatable curing results
OmniCure AC275 and AC2110
Compact UV LED Curing Systems for Inks, Coatings and Adhesives
www.excelitas.com
02.26.2015
Outstanding Optical PerformanceThe OmniCure® AC275 and AC2110 air-cooled UV LED curing systems are designed with advanced front-end optics to provide high peak irradiance and exceptional uniformity. The standard AC2 systems provide a reduced output angle from typical LED systems, ideal for printing applications, to help eliminate back reflection of the light to the print heads. Customized optics are available to maximize the irradiance for longer working distances. All AC2 Series come with a flat outer surface that allows for easy cleaning and replacement for ongoing maintenance. By adapting the output to support the process requirements of the industry, the new AC2 Series product portfolio can be applicable for a range of varying applications with different process needs.
Ease of IntegrationOmniCure AC2 Series UV LED curing systems utilize air-cooled LED technology to provide high irradiance in a very compact design allowing for seamless integration into new or existing print systems or production lines. The curing systems can also be mounted in any orientation for greater flexibility. External mechanical and optical accessories are also available upon request.
Mechanical DrawingsMechanical drawings are available on our website. To find out more about the OmniCure AC Series of UV LED curing solutions, please visit www.excelitas.com/omnicure
Exceptional Process ControlFor a repeatable curing process, precise control of the UV irradiance level and exposure time ensures that the correct dose of UV energy is provided every time. Intelligent system monitoring and control ensures system reliability meets the demands of any application. Multiple wavelengths are available to match the requirements of the material to be cured.
Superior UniformityThe OmniCure AC2 Series utilizes a patented process for addressing individual UV LED module outputs, and provides exceptional uniformity over the entire curing area. Multiple UV LED heads can be adjoined while maintaining optical uniformity between each system. The flexibility to achieve larger curing areas in a variety of customizable lengths enables manufacturers to improve throughput without compromising on performance.
Technical Specifications
2260 Argentia Road Mississauga, OntarioL5N 6H7 CANADA
Telephone: +1 905 821-2600Toll Free (USA and CAN): +1 800 668-8752Fax: +1 905 821-2055
www.excelitas.com [email protected]
© 2015 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, and neither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein for reference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors.
02.2015
AC275 AC2110
LED Peak Wavelengths
395 nm ± 5 nm, 365 nm ± 5 nm
Active Optical Area
10 x 76 mm 10 x 114 mm
Typical Peak Irradiance (W/cm2)
395 nm 395 nm
Working Distance
1 mm 2.6 2.6
3 mm 2.3 2.3
5 mm 1.9 1.9
10 mm 1.2 1.2
15 mm 1.0 1.0
20 mm 0.8 0.8
Optical Power* 13 W 19 W
Longitudinal Uniformity*
Better than ± 10%
Operating Voltage
48 V DC ± 2 V
Dimensions (L x W x H)
79 x 29 x 129 mm 117 x 29 x 129 mm
Weight (kg) 0.3 0.44
*At 100% output settingNote: All measurements are taken using the EIT PowerPuck II radiometer with UVA2 filter.
Irradiance vs. Working Distance for AC2 Series – 395 nm
1 mm3 mm5 mm10 mm15 mm20 mm
Irra
dia
nce
(W
/cm
2 )
Lateral Displacement (cm)
-3 -2 -1 0 1 2 3
3.0
2.5
2.0
1.5
1.0
0.5
0
AC2 Series Uniformity – 395 nm
Rel
ativ
e Po
wer
per
Un
it L
eng
th (
%)
3 mm5 mm10 mm15 mm20 mm
Longitudinal Displacement (mm)
20 40 60 80 100 120 140 160 180 200
100
80
60
40
20
0