AC3 Rated CapacityIEC 60947-4-1CNS 2930JEM1038JIS C8325GB 14048.4-2010
UL Specification
Rated Continuous Current AC1 (A)
UL 508
Rated Capacity
CSA C22.2
AC3. 1.0
Auxiliary Contacts
Continuous Current (Ith A)
Continuous Current (Ith A)
Coil Rating (VA)
Reaction Time (S)
Protection Device - Fast Fuse (A)
Contact Structure
Open typeEnclosed TypeEnclosed Type (with buttons)
Open TypeEnclosed Type
Electrical Operations AC3 (unit:104)
Mechanical Operations (unit:104)
Numbers of switchings / hour
A Type Magnetic Starter(RAB- )
A Type Reversing Magnetic Starter (RRAB- )
Selection Of ThermalOverload Relay
(Standard)
Operating Voltage
AC15 A600DC13 Q300
Releasing VoltageSwitching (VA)Keeping (VA)Loss (W)Closing (mS)Releasing (mS)
IP 65IP 65IP 42IP 42
BTH-A25(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-A36(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-18T(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-35T(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Contactor Models (TYPE)
Rated Insulation Voltage (Ui)IEC /CNS (V)
Rated Operational Voltage (Ue)IEC /CNS (V)
Continuous Operational Current(Ith) IEC /CNS (A)
Continuous Operational Current(Ith) UL (A)
Ie Max AC3 under 460V Current (A)
AC4 Current (A)
690/600
660/600
25
24
12
2.7
690/600
660/600
25
25
16
5
690/600
660/600
32
32
18
7
690/600
660/600
35
35
24
10
110V220V220V380V440V550V
120V240V240V380V460V575V
Single phase
Three phase
Single phase
Three phase
RAB-A15 RAB-A18 RAB-A24
KW
0.55
1.1
3
5.5
5.5
7.5
HP
0.75
1.5
4
7.5
7.5
10
0.37
1.5
2.2
3.7
5.5
7.5
24 24 32 32
0.5
2
3
5
7.5
10
0.37
1.5
2.2
3.7
0
7.5
0.5
2
3
5
7.5
10
0.75
2.2
3.7
5.5
7.5
9
1
3
5
7.5
10
12
0.75
2.2
3.7
5.5
7.5
9
1
3
5
7.5
10
12
KW
0.55
1.1
3
6.5
6.5
9
HP
0.75
1.5
4
8.5
8.5
12.5
KW
0.75
1.5
4
7.5
9
10
HP
1
2
5.5
10
12
13.5
KW
1.1
2.2
5.5
11
11
12
HP
1.5
3
7.5
15
15
16
RAB-A12
3P 1a or 1b
10
2.5
25
3P 1a 1b
10
2.5
25
3P 1a 1b
10
2.5
32
3P 1a 1b
10
2.5
35
80
8
1.8~2.2
11~21
8~18
A12 S1/E1
A12 S26/E26
A12 S36/E36
A12 S1/E1
A12 S2/E2
80
8
1.8~2.2
11~21
8~18
A15 S1/E1
A15 S26/E26
A15 S36/E36
A15 S1/E1
A15 S2/E2
80
8
1.8~2.2
11~21
8~18
A18 S1/E1
A18 S26/E26
A18 S36/E36
A18 S1/E1
A18 S2/E2
80
8
1.8~2.2
11~21
8~18
A24 S1/E1
A24 S26/E26
A24 S36/E36
A24 S1/E1
A24 S2/E2
1200
100
1000
85%~110%
< 55%
0.45 0.72 0.96 1.45 2.6 3.4 4.2
6 8 9 11 13 18 25
0.45 0.72 0.96 1.45 2.6 3.4 4.2
6 8 9 11 13 18 25
AC3 Rated CapacityIEC 60947-4-1CNS 2930JEM1038JIS C8325GB 14048.4-2010
UL Specification
Rated Continuous Current AC1 (A)
UL 508
Rated Capacity
CSA C22.2
AC3. 1.0
Auxiliary Contacts
Continuous Current (Ith A)
Continuous Current (Ith A)
Coil Rating (VA)
Reaction Time (S)
Protection Device - Fast Fuse (A)
Contact Structure
Open typeEnclosed TypeEnclosed Type (with buttons)
Open TypeEnclosed Type
Electrical Operations AC3 (unit:104)
Mechanical Operations (unit:104)
Numbers of switchings / hour
A Type Magnetic Starter(RAB- )
A Type Reversing Magnetic Starter (RRAB- )
Selection Of ThermalOverload Relay
(Standard)
Operating Voltage
AC15 A600DC13 Q300
Releasing VoltageSwitching (VA)Keeping (VA)Loss (W)Closing (mS)Releasing (mS)
IP 65IP 65IP 42IP 42
BTH-A25(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-A36(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-18T(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-35T(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Contactor Models (TYPE)
Rated Insulation Voltage (Ui)IEC /CNS (V)
Rated Operational Voltage (Ue)IEC /CNS (V)
Continuous Operational Current(Ith) IEC /CNS (A)
Continuous Operational Current(Ith) UL (A)
Ie Max AC3 under 460V Current (A)
AC4 Current (A)
110V220V220V380V440V550V
120V240V240V380V460V575V
Single phase
Three phase
Single phase
Three phase
690/600
660/600
40
40
25
11
690/600
660/600
45
40
30
12
690/600
660/600
50
45
35
14
690/600
660/600
60
45
36
15
RAB-A30 RAB-A36
40 40 45 45
1.5
2.2
5.5
7.5
11
11
2
3
7.5
10
15
15
1.5
2.2
5.5
7.5
11
11
2
3
7.5
10
15
15
1.5
3.7
7.5
11
15
15
2
5
10
15
20
20
1.5
3.7
7.5
11
15
15
KW
1.1
2.2
5.5
11
11
12
HP
1.5
3
7.5
15
15
16
KW
1.5
3.7
6.5
12
12
15
HP
2
5
8.5
16
16
20
KW
1.5
3.7
7.5
15
15
18.5
HP
2
5
10
20
20
25
KW
1.8
3.7
9
15
18.5
18.5
RAB-A25
3P 1a 1b
10
2.5
40
3P 1a 1b
10
2.5
40
3P 1a 1b
10
2.5
50
3P 1a 1b
10
2.5
50
115
11
3~4
11~21
8~18
A25 S1/E1
A25 S26/E26
A25 S36/E36
A25 S1/E1
A25 S2/E2
115
11
3~4
11~21
8~18
A30 S1/E1
A30 S26/E26
A30 S36/E36
A30 S1/E1
A30 S2/E2
115
11
3~4
11~21
8~18
A35 S1/E1
A35 S26/E26
A35 S36/E36
A35 S1/E1
A35 S2/E2
115
11
3~4
11~21
8~18
A36 S1/E1
A36 S26/E26
A36 S36/E36
A36 S1/E1
A36 S2/E2
RAB-A35
1200
100
1000
85%~110%
< 55%
18 26 36
18 26 36
2
5
10
15
20
20
HP
2.5
5
12.5
20
25
25
H=130
105.
512
814
.54075
H=115
105.
512
814
.54075
M5安裝孔M5安裝孔
AC3 Rated CapacityIEC 60947-4-1CNS 2930JEM1038JIS C8325GB 14048.4-2010
UL Specification
Rated Continuous Current AC1 (A)
UL 508
Rated Capacity
CSA C22.2
AC3. 1.0
Auxiliary Contacts
Continuous Current (Ith A)
Continuous Current (Ith A)
Coil Rating (VA)
Reaction Time (S)
Protection Device - Fast Fuse (A)
Contact Structure
Open typeEnclosed TypeEnclosed Type (with buttons)
Open TypeEnclosed Type
Electrical Operations AC3 (unit:104)
Mechanical Operations (unit:104)
Numbers of switchings / hour
A Type Magnetic Starter(RAB- )
A Type Reversing Magnetic Starter (RRAB- )
Selection Of ThermalOverload Relay
(Standard)
Operating Voltage
AC15 A600DC13 Q300
Releasing VoltageSwitching (VA)Keeping (VA)Loss (W)Closing (mS)Releasing (mS)
IP 42IP 42IP 42IP 42
BTH-80K(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-80(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-125/185(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-A25(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Contactor Models (TYPE)
Rated Insulation Voltage (Ui)IEC /CNS (V)
Rated Operational Voltage (Ue)IEC /CNS (V)
Continuous Operational Current(Ith) IEC /CNS (A)
Continuous Operational Current(Ith) UL (A)
Ie Max AC3 under 460V Current (A)
AC4 Current (A)
690/600
660/600
80
—
50
18
110V220V220V380V440V550V
120V240V240V380V460V575V
Single phase
Three phase
Single phase
Three phase
KW
2.2
5.5
11
22
22
22
HP
3
7.5
15
30
30
30
KW
3
5.5
15
30
30
30
HP
4
7.5
20
40
40
40
KW
3.75
7.5
19
37
40
40
HP
5
10
25
50
54
54
KW
4.5
9
22
45
45
45
HP
6
12.5
30
60
60
60
1000
100
500
KW
4.5
9
25
50
50
50
HP
6
12.5
35
70
70
70
RAB-50T
3P 1a 1b
10
2.5
80
200
20
6~9
16~25
9~20
50T S1/E1
50T S2/E2
50T S3/E3
50T S1/E1
50T S2/E2
3P 1a 1b
10
2.5
90
200
20
6~9
16~25
9~20
65T S1/E1
65T S2/E2
65T S3/E3
65T S1/E1
65T S2/E2
3P 1a 1b
10
2.5
100
220
20
6~10
20~35
9~20
72T S1/E1
72T S2/E2
72T S3/E3
72T S1/E1
72T S2/E2
3P 1a 1b
10
2.5
110
220
20
6~10
20~35
9~20
78T S1/E1
78T S2/E2
78T S3/E3
78T S1/E1
78T S2/E2
3P 1a 1b
10
2.5
140
220
20
6~10
20~35
9~20
95T S1/E1
95T S2/E2
—
95T S1/E1
95T S2/E2
690/600
660/600
90
—
65
22
RAB-65T690/600
660/600
100
—
75
26
RAB-72T690/600
660/600
110
—
80
30
RAB-78T690/600
660/600
140
—
95
35
RAB-95T
42 52 63 80 100
41 48 56 80
H=145
110
130
8092
H=160
130
150
100120
M6安裝孔
85%~110%
< 55%
1000
100
500
KW
4.5
9
25
50
50
50
HP
6
12.5
35
70
70
70
KW
—
—
30
60
60
60
HP
—
—
40
80
80
80
KW
—
—
33
63
63
63
HP
—
—
45
85
85
85
KW
—
—
37
75
75
75
HP
—
—
50
100
100
100
KW
—
—
45
90
90
90
HP
—
—
60
125
125
125
3P 2a 2b
10
2.5
140
200
20
6~9
23~35
5~15
88T S1/E1
88T S2/E2
—
88T S1/E1
88T S2/E2
3P 2a 2b
10
2.5
150
660
60
12~16
23~35
7~16
110T S1/E1
110T S2/E2
—
110T S1/E1
110T S2/E2
3P 2a 2b
10
2.5
165
660
60
12~16
23~35
7~16
125T S1/E1
125T S2/E2
—
125T S1/E1
125T S2/E2
3P 2a 2b
10
2.5
170
660
60
12~16
23~35
7~16
135T S1/E1
135T S2/E2
—
135T S1/E1
135T S2/E2
3P 2a 2b
10
2.5
200
660
60
12~16
23~35
7~16
155T S1/E1
155T S2/E2
—
155T S1/E1
155T S2/E2
1000/600
690/600
140
—
100
35
RAB-88T1000/600
690/600
150
—
115
40
RAB-110T1000/600
690/600
165
—
125
45
RAB-125T1000/600
690/600
170
—
135
52
RAB-135T1000/600
690/600
200
—
150
60
RAB-155T
80 90 107 130
3.6 (Through Current Transformer)
AC3 Rated CapacityIEC 60947-4-1CNS 2930JEM1038JIS C8325GB 14048.4-2010
UL Specification
Rated Continuous Current AC1 (A)
UL 508
Rated Capacity
CSA C22.2
AC3. 1.0
Auxiliary Contacts
Continuous Current (Ith A)
Continuous Current (Ith A)
Coil Rating (VA)
Reaction Time (S)
Protection Device - Fast Fuse (A)
Contact Structure
Open typeEnclosed TypeEnclosed Type (with buttons)
Open TypeEnclosed Type
Electrical Operations AC3 (unit:104)
Mechanical Operations (unit:104)
Numbers of switchings / hour
A Type Magnetic Starter(RAB- )
A Type Reversing Magnetic Starter (RRAB- )
Selection Of ThermalOverload Relay
(Standard)
Operating Voltage
AC15 A600DC13 Q300
Releasing VoltageSwitching (VA)Keeping (VA)Loss (W)Closing (mS)Releasing (mS)
IP 42IP 42IP 42IP 42
BTH-80K(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-80(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-125/185(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-A25(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Contactor Models (TYPE)
Rated Insulation Voltage (Ui)IEC /CNS (V)
Rated Operational Voltage (Ue)IEC /CNS (V)
Continuous Operational Current(Ith) IEC /CNS (A)
Continuous Operational Current(Ith) UL (A)
Ie Max AC3 under 460V Current (A)
AC4 Current (A)
110V220V220V380V440V550V
120V240V240V380V460V575V
Single phase
Three phase
Single phase
Three phase
160
180
H=195135110
M6安裝孔
180
220
H=215155130
M8安裝孔
85%~110%
< 55%
1000
100
500
KW
—
—
45
90
90
90
HP
—
—
60
125
125
125
KW
—
—
55
110
110
110
HP
—
—
75
150
150
150
KW
—
—
65
120
125
132
HP
—
—
85
160
170
180
KW
—
—
75
132
150
150
HP
—
—
100
180
200
200
KW
—
—
90
160
160
160
HP
—
—
125
220
220
220
KW
—
—
110
224
224
260
HP
—
—
150
300
300
350
3P 2a 2b
10
2.5
200
970
66
18~24
23~35
8~18
150T S1/E1
150T S2/E2
—
150T S1/E1
150T S2/E2
3P 2a 2b
10
2.5
240
970
66
18~24
23~35
8~18
180T S1/E1
180T S2/E2
—
180T S1/E1
180T S2/E2
3P 2a 2b
10
2.5
260
1100
110
30~40
23~35
8~18
225T S1/E1
225T S2/E2
—
225T S1/E1
225T S2/E2
3P 2a 2b
10
2.5
330
1300
120
30~40
23~35
8~18
260T S1/E1
260T S2/E2
—
260T S1/E1
260T S2/E2
3P 2a 2b
10
2.5
400
1300
120
30~40
23~35
8~18
300T S1/E1
300T S2/E2
—
300T S1/E1
300T S2/E2
3P 2a 2b
10
2.5
425
1300
120
30~40
23~35
8~18
450T S1/E1
450T S2/E2
—
450T S1/E1
450T S2/E2
1000/600
690/600
200
—
165
64
RAB-150T1000/600
690/600
240
—
200
78
RAB-180T1000/600
690/600
260
—
225
85
RAB-225T1000/600
690/600
330
—
260
91
RAB-260T1000/600
690/600
400
—
300
104
RAB-300T1000/600
690/600
425
—
400
137
RAB-450T
3.6 (Through Current Transformer)
AC3 Rated CapacityIEC 60947-4-1CNS 2930JEM1038JIS C8325GB 14048.4-2010
UL Specification
Rated Continuous Current AC1 (A)
UL 508
Rated Capacity
CSA C22.2
AC3. 1.0
Auxiliary Contacts
Continuous Current (Ith A)
Continuous Current (Ith A)
Coil Rating (VA)
Reaction Time (S)
Protection Device - Fast Fuse (A)
Contact Structure
Open typeEnclosed TypeEnclosed Type (with buttons)
Open TypeEnclosed Type
Electrical Operations AC3 (unit:104)
Mechanical Operations (unit:104)
Numbers of switchings / hour
A Type Magnetic Starter(RAB- )
A Type Reversing Magnetic Starter (RRAB- )
Selection Of ThermalOverload Relay
(Standard)
Operating Voltage
AC15 A600DC13 Q300
Releasing VoltageSwitching (VA)Keeping (VA)Loss (W)Closing (mS)Releasing (mS)
IP 42IP 42IP 42IP 42
BTH-80K(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Optional)
BTH-80(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-125/185(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Selection Of ThermalOverload Relay
(Standard)
BTH-A25(Marking Value)(A)
2H Overload protection
2E Overload and Phase Failure Protection
Contactor Models (TYPE)
Rated Insulation Voltage (Ui)IEC /CNS (V)
Rated Operational Voltage (Ue)IEC /CNS (V)
Continuous Operational Current(Ith) IEC /CNS (A)
Continuous Operational Current(Ith) UL (A)
Ie Max AC3 under 460V Current (A)
AC4 Current (A)
110V220V220V380V440V550V
120V240V240V380V460V575V
Single phase
Three phase
Single phase
Three phase