HARRIS COUNTY PSYCHIATRIC CENTER UNIT 1DAND 2B RENOVATION
2800 S. MACGREGOR WAYHOUSTON, TEXAS 77021
14265
GAS EVACUATIONWAGE WASTE ANESTHETIC
CARE UNITCYSTOSCOPYCYSTO
INTRAVENOUSIVISOLATIONISOLIN-PATIENTIPINFANTINF
POST PARTUM
XR X RAY
WG (WG-) WALL GUARD
VACVAC CTR
VACUUM LINEVACUUM CONTAINER
VAC SL VACUUM SLIDE
UCUCL
UNDER CABINETUNDER CABINET LIGHT
TL TASKLIGHT
TREAT TREATMENTTELEM TELEMETRY
SURGSWBD
SURGICALSWITCHBOARD
SUCT SUCTIONSU SOILED UTILITYSTER STERILIZERSPHYG SPHYGMOMANOMETERSPCL SPECIAL
SHOWER CURTAIN
SECL RMSHARPS
(SHR CURT-)SHR SEAT(SHR SEAT-)SICUSNF
SHR CURT
SECLUSION ROOMSHARPS CONTAINER
SHOWER SEAT
SURGICAL INTENSIVE CARE UNITSKILLED NURSING FACILITY
RADIO FREQUENCY
RADIOLRH(RB HK-)R/FRECOVREG
RADIOLOGYROBE HOOK
RAD/FLUORO
REGISTRATIONRECOVERY ROOM
RMW REGULATED MEDICAL WASTERF
PU (PU-) PASS THROUGH UNITPTS PNEUMATIC TUBE STATIONPROC PROCEDUREPHAR PHARMACY(PG BD-)
PACUPATPATHPEDSPETPG BD
POST ANETHESIA CARE UNIT
PATHOLOGYPEDIATRIC(S)POSITION EMISSION TOMOGRAPHYPEG BOARD
PATIENT
O2OBOPORORTHOOTO
OXYGENOBSTETRICSOUT PATIENTOPERATING ROOMORTHOPEDICSOTOSCOPE/OPTHALMOSCOPE
NIGHT LIGHT
N20NARC
NUCNSNLNEURONC
NUR
NITROUS OXIDENARCOTICS
NURSE STATION
NEUROLOGYNURSE CALL
NUCLEARNURSE(RY)
N2 NITROGEN
MRI MAGNETIC RESONANCE IMAGING
MED MEDICINE/MEDICATIONMEDICINE CABINET
MAGMAMMOMC (MC-)
(MED EQUIP-)MICUMON
MED EQUIP
MAGNET(IC)MAMMOGRAOHY
MEDICAL EQUIPMENT
MEDICAL INTENSIVE CARE UNITMONITOR
LTC LONG TERM CARELS (LS-) LINOLEUM SHEETLL LEAD LINEDLN LINENLG LOUNGE
LDRP LABOR/DELIVERY/RECOVERY/LDR LABOR/DELIVERY/RECOVERY(LAB EQUIP-)
LABLAB EQUIP
LABORATORYLABORATORY EQUIPMENT
ICCU INTENSIVE CARDIAC CARE UNITICU INTENSIVE CARE UNIT
HCHCP
HEALTH CAREHANDICAP(PED)
GLVGSUGWTGYN
GLOVEGLAZED STRUCTURAL UNITSGLAZED WALL TILEGYNECOLOGY
ENDOEREXAM
ENDOSCOPYEMERGENCY ROOMEXAMINATION
ED EMERGENCY DEPARTMENT
DISTWDIDK RMDWTR
DISTILLED WATERDEIONIZED WATERDARK ROOMDUMBWAITER
CVICU CARDIOVASCULAR INTENSIVECLN UTIL CLEAN UTILITYCT COMPUTERIZED TOMOGRAPHYCS CLINICAL SINKC02 CARBON DIOXIDECODE CODE CARTCLN CLEAN
CARDIOCATH
CARDIOLOGYCATHETERIZATIONCUBICAL CURTAIN TRACK
CBCHT
CODE BLUECHANGE TABLE
CC (CC-)
BW BLANKET WARMERBUMPER RAILBR
BP (BP-) BED PAN HOLDERBED LOCATORBL
BG (BG-) BUMPER GUARD
ANGIO ANGIOGRAPHYANESTH ANESTHESIOLOGY
ADMITTINGACID RESISTINGAIR
ACID RESA
ADMIT
PARTITION & DOOR NOTES
14. DO NOT REDUCE THE WIDTH OF PUBLIC CORRIDORS.
15. FULLY LAY OUT GRID, WALL, AND OPENING PLACEMENT IN AN AREA PRIOR TO START OF PARTITION CONSTRUCTION. VERIFYTHAT DIMENSIONS ARE CONSISTENT WITH REQUIREMENTS INDICATED IN THE DOCUMENTS.REFER ANY DIMENSIONAL INCONSISTENCIES TO THE ARCHITECT FOR RESOLUTION PRIOR TO THE START OF PARTITIONCONSTRUCTION.
16. FINISH FLOOR ELEVATIONS ARE TO TOP OF HORIZONTAL SHEATHING UNLESS OTHERWISE NOTED.
17. LEVEL FLOOR THAT EXCEEDS 1/4" VARIANCE IN A 10'-0" RADIUS.
18. COORDINATE EXACT SIZE AND PLACEMENT OF EQUIPMENT BASE AND HOUSEKEEPING PADS WITH EQUIPMENT TO BEPROVIDED.
19. COORDINATE INSTALLATION OF DIFFUSERS, SPEAKERS, SPRINKLER HEADS, AND ACCESS PANELS WITH LIGHTING LAYOUT.REPORT ANY CONFLICTS TO THE ARCHITECT PRIOR TO INSTALLATION.
20. EXIT SIGNS AND SMOKE DETECTORS LOCATED IN HARD CEILINGS SHALL BE POSITIONED AS REQUIRED BY THE AUTHORITYHAVING JURISDICTION, AND SHALL BE CENTERED IN CORRIDORS AND LOCATED A DISTANCE OF 1'-0" FROM THE WALL TO THECENTER OF THE FIXTURE UNLESS OTHERWISE NOTED.
21. PROVIDE TAMPER PROOF AND/OR LOCKABLE ACCESS PANELS IN GYPSUM BOARD CEILINGS AT LOCATIONS SHOWN, OR IF NOTSHOWN, AS REQUIRED TO ACCESS ALL MECHANICAL EQUIPMENT IN THE CEILING CAVITY REQUIRING NORMAL AINTENANCE OROPERATION, INCLUDING BUT NOT LIMITED TO CONSTANT AIR, OR VARIABLE AIR VOLUME BOXES, REHEAT COILS, VALVES, EXHAUSTFANS, BALANCING DAMPERS, FIRE DAMPERS, SMOKE DAMPERS, FIRE/SMOKE DETECTORS, CLEAN OUTS, OR IF NOT SHOWN, ASREQUIRED TO ACCESS ALL MECHANICAL EQUIPMENT AND JUNCTION BOXES. SUBMIT LAYOUT OF ALL REQUIRED CEILINGELEMENTS, INCLUDING CCESS PANELS, FOR ARCHITECTS' REVIEW PRIOR TO INSTALLATION. LOCATE EQUIPMENT AND VALVESTO MINIMIZE THE NEED FOR ACCESS PANELS.
22. GANG MULTIPLE SWITCHES TOGETHER INTO ONE BOX WITH A SINGLE COVER PLATE WHENEVER POSSIBLE.MULTIPLE SWITCHES, WHICH CANNOT BE GANGED TOGETHER IN THE SAME BOX, SHALL BE LOCATED AS CLOSE TOGETHER ASPOSSIBLE AND MOUNTED AT THE SAME HEIGHT.
23. APPROVE FLOOR OUTLET LOCATIONS WITH ARCHITECT AND BUILDING MANAGEMENT PRIOR TO CORE DRILLING.
24. WALL OUTLETS SHALL BE INSTALLED AT 18" AFF AND INSTALL SWITCH PLATES AT 44" AFF UNO UNLESS OTHERWISE NOTED.
25. DO NOT INSTALL OUTLETS OR J-BOXES BACK-TO-BACK ON OPPOSITE SIDES OF WALL. BOXES MUST BE SEPARATED BY A STUD.
26. CAULK FLOOR AND WALL OUTLETS WITH AN ACOUSTIC SEALANT.
FRE FLOOR REFERENCE ELEVATION
(TSCD-)
(TKBD-)
(SNDU-)
PLASTIC LAMINATE
MIRROR(MIRR-)
ALUMINUM(ALUM-)
UNDER CABINET LIGHTING
(MKR BD-)
(INSUL-)VNR (VNR-) VENEER
UC UNDER CABINETUCL (UCL-)
STORAGE
THRES THRESHOLD
SSM (SSM-) SOLID SURFACE MATERIAL
DISPOSAL UNITSNDU SANITARY NAPKINSND (SND-) SANITARY NAPKIN DISPENSER
SGL SINGLE
RUBBER TILE FLOORRTF (RTF-)RUBBERRUB
PSH (PSH-) PURSE SHELF
(PROJ SCRN-)
PERFORATEDPERF
OWNER FURNISHED,OF/OIOWNER INSTALLED
CONTRACTOR INSTALLEDOF/CI OWNER FURNISHED,
KICK PLATEKPL (KPL-)
FIRE CABINETFC (FC-)
DISHWATERDW
BENCHBE (BE-)
AMERICANS WITH DISABILITIES ACTADA
TOWEL DISPENSER/ RECEPTACLE
TOILET SEAT COVER DISPENSER
UNDERWRITER'S LABORATORIES
SOUTHSOUND ATTENUATION BATTS
SHOWER
SIGNAGE
SHEET
SANITARYSOLID CORE
SECTION
SCHEDULE
SQUARE FOOT(FEET)
SOAP DISPENSER
STATION
SPEAKER
STANDPIPESPECIFICATION
SQUARESERVICE SINK
STAINLESS STEEL
SOUND TRANSMISSION CLASS
SHEET VINYLSYMMETRICAL
STEEL
STRUCTURE, STRUCTURALSUSPENDED
STONE
STANDARD
SIMILAR
TELEPHONETEMPORARY
TOP OFTREAD
TONGUE & GROOVETOP & BOTTOM
TREATED
THICK
TENANT IMPROVEMENT
TEMPEREDTOILET
TACKBOARD
TOILET PAPER DISPENSERTOPOGRAPHY, TOPOGRAPHIC
TERRAZZO
UNEXCAVATEDUNFINISHED
TYPICALTELEVISION
HEAT TRANSFER COEFFICIENT
UNIT HEATERUNDERGROUND
UNDERSLABUTILITY
UNLESS NOTED OTHERWISE
TUBE STEEL
VOLUME
VINYL TILE
VENTILATION
VESTIBULEVERTICAL
VAPOR RETARDER
VINYL COMPOSITION TILE
VERIFY IN FIELD
WATER CLOSET
WALL GUARDWOOD
WIDE FLANGE
WITHOUT
WESTWITH
VINYL WALL COVERING
WEIGHTWAINSCOT
WIRE MESHWINDOW
WATER HEATERWROUGHT IRON
WASTE RECEPTACLE
WELDED WIRE FABRIC
WATER PROOFING
YARD
ZINC.
VINYL BASE
SABS
SHR
SGNG
SHT
SANSC
SECTSD (SD-)SCHED
SF
GAUGEGALVANIZEDGALV
GA
GLASSGROUND
GENERALGRAB BAR
GLASS FIBER
GLASS FIBER
GDGL (GL-)
GFRCGENGB (GB-)
GFRGREINFORCED CONCRETE
REINFORCED GYPSUM
SSSTASTC
SPKR
SPSPEC
SQSRS
SV (SV-)SYMM
STL
STORSTRUCTSUSP
STN (STN-)
STD
HIGHHOSE BIBB
GRADE
GYPSUM
GREASE TRAP
HHB
GT
GRGLU LMW
GYP
HORIZONTAL
HOURHEIGHT
HIGH POINT
HANDICAPPED
HOLLOW METALHOLD OPEN
HARDWOODHARDWARE
HORIZHPHRHT
HDW
HCP
HMHO
HD
HC HOLLOW CORE
GLUE LAMINATED WOOD
SIM
ANCHOR BOLTAIR CONDITION(ING)(ED)
AGGREGATE
ADJUSTABLE
AREA DRAIN
ACOUSTIC(AL)ACCESS PANEL
ADHESIVE
ABOVE FINISHED FLOOR
ACOUSTICAL CEILING TILEACOUSTICAL CEILING PANEL
ABAC
ADJ
AGGR
AFF
ACT (ACT-)AD
ACP (ACP-)
ACS PNLACST
ADH
APPROXIMATE
ASPHALTARCHITECT(URAL), ARCHITECT
ALTERNATE
ANNUNCIATORANODIZE(D)
AIR HANDLING UNIT
BOARD
BUILDINGBITUMINOUS
BASE BOARD
BACK TO BACKBULLETIN BOARD
ACOUSTICAL WALL PANELAUTOMATIC
APPROX
ASPHARCH
ALTAL
AHU
ANNANOD
BD
BLDGBITUM
AWP (AWP-)
B/BBB (BB-)B BD
AUTO
AHR ANCHOR
TELTDR (TDR-)
TEMP
T/
T>&B
t
TOPOTPD (TBD-)TRTD
THK
TI
TMPDTLT
TKBD
TER (TER-)
HYDRANT
HEATERHEATING
HOT WATERHYD
ID
HVAC
HW
HTRHTG
INVERT
JANITOR
INTERMEDIATEINTERIOR
INCANDESCENTINCH(ES)
INCLUDE(D), INCLUDINGINSULATION
INV
JAN
INT
IN
INCLINSUL
INTERM
INCAND
HEATING, VENTILATION,AIR CONDITIONING
INSIDE DIAMETER
UNEXCUNFIN
U
TYP
TSCD
TV
TS
ULUHUGND
UNO
USUTIL
KNOCK OUTKITCHEN
JOINT
KNOCK(ED) DOWNKOKIT
JT
KD
LEFT HANDLIVE LOAD
POUND(S)
LONG, LENGTH
LAUNDRY
LAMINATE(D)
LAVATORY
LHLL
LAU
LLM
LB(S)LAV
BEARING
BASEMENTBRONZE
BRICK
BENCHMARK
BOTTOM OF
BEAM
BOTTOM
CORNER GUARD
CAST IRONCOAT HOOK
CABINETCATCH BASIN
CEMENT
BUILT-UP ROOFING
BRG
BSMTBRZ
BR (BR-)
BOTB MKBM
BOT/
CG (CG-)
CICH (CH-)
CABCB
CEM
BUR
CLEARCENTIMETER
CENTER LINECEILINGCLOSET
CIRCULATIONCONTROL JOINT
CONCRETE MASONRY UNIT
CONTINUOUS
COORDINATECONTRACTOR
CONFERENCE
COLUMNCONCRETE
CONSTRUCTIONCONNECTION
CLEANOUT
CLRcmCMU
CJCL
CLOCLG
CIRC
CONT
COORDCONTR
CONSTRCONNCONFCONCCOLCO
CIP CAST-IN-PLACE
VOL
VT (VT-)VR
VCT (VCT-)VENTVERT
VIFVEST
WCWD (WD-)WG (WG-)
VWC (VWC-)
W/O
WW/
LIGHTINGLEVEL
LIGHT(S)LOW POINT
LTGLVLLWC
LLH
LPLT(S)
LNGLLV
MAXIMUM
METER
MATERIAL
MAINTENANCEMACHINE
MASONRY
MCBMAX
MDO
MATL
MAINTMACHm
MAS
METAL CORNER BEADMEDIUM DENSITY OVERLAY
LONG LEG HORIZONTAL
LONGITUDE, LONGITUDINAL
LIGHT WEIGHT CONCRETE
LONG LEG VERTICAL
W RECPT
WWFWTWSCT
WINWMWP
WHWI
YD
ZN
MINIMUM
MANUFACTURERMANHOLE
MEMBRANEMEZZANINE
MECHANICAL
MINMHMFR
MEMBMEZZMEP
MECH
METALMEETING
MULLION
MARKER BOARDMISCELLANEOUS
MILLIMETER
MOUNTED
MTLMTG
MULL
MISC
MOmm
MIRR
MKR BD
MTDMASONRY OPENING
PLUMBINGMECHANICAL, ELECTRICAL,
MEDIUM DENSITY FIBERBOARDMDF
WF
COLD WATERCUBIC
CERAMIC TILECENTER
COUNTERSINKCARPET
CLOSED CIRCUIT TELEVISION
DEGREE
DEPARTMENTDETAIL
DEEP, DEPTHDOUBLE
DEMOLISH, DEMOLITION
DIAPER CHANGING TABLE
CW
CCTV
CSKCPT (CPT-)
CT (CT-)
CUCR
DEGDEMODEPTDET
DCT (DCT-)
DDBL
DIVISIONDEAD LOADDOWN
DIFFUSER
DISPENSERDIMENSION
DIAGONALDIAMETER
DOWNSPOUT
DRAWING
DOOR
DRAINAGE, WASTE AND VENT
DAMPPROOFING
DIVDLDN
DIFF
DISPDIM
DIADIAG
DS
DWVDWG
DRDP
DF (DF-) DRINKING FOUNTAIN
CORR CORRIDOR
LKR (LKR-) LOCKER
VB (VB-)
BLKG BLOCKING NOMINALNOT TO SCALEOUT TO OUT
NORTH
NUMBERNOMNTS
N
NONIC
OPPOSITE HANDOPENINGOPPOSITE
OVERALLON CENTER
OFFICEOVERHEAD
OPNGOPP
OPH
OAOC
OHOFFOFD
OD
O/O
NOT IN CONTRACT
OVERFLOW DRAIN
OUTSIDE DIAMETER
PLATE
PLASTER
PEG BOARDPERPENDICULAR
PLPLA
PLAS
PGBD
PBD
PCC (PCC-)
PA
PERP
PROJECTPARKING
PANEL
PAIR
PAINT
POLISHED
PLYWOOD
PREFAB
PROJPRKG
PNLPOLPR
PTPWPLBG PLUMBING
PREFABRICATE(D)
PARTICLE BOARDPUBLIC ADDRESS
PRE-CAST CONCRETE
ELASTOMERIC
ELEVATORELECTRIC(AL)
EASTEACH
FINISH SYSTEM
ELEVATIONEXPANSION JOINT
EXTERIOR INSULATION AND
EQUAL, EQUIVALENTEQUIPMENT
ENGINEERENCLOSURE
ENTRANCEELECTRIC OUTLETEDGE OF SLABELECTRICAL PANEL
EMERGENCY SHOWER
EMERGENCY
ELAST
ELEVELEC
EEAEIFS
ELEJ
EP
EQUIP
ES
EQ
ENGRENCL
EOENTR
EOS
EMER
EXISTINGEXPANSIONEXPOSED
EXHAUSTEXCAVATION, EXCAVATE
EACH WAYETCETERA
EXTERIOR, EXTERNAL
ELECTRIC WATER COOLER
FACE TO FACEFIRE ALARM
FACE OF
FIRE ALARM ANNUNCIATOR PANEL
EXPEXPOEXT
EXIST
EXCEWCEW
EXH
ETC
F/F
FAAPFA
F/
PARTITION
PAVING
POINT
PROPERTY
PTN
PVGPVC
PSF
PSI
PROP
PTPTD (PTD-)
RADIUSRUBBER BASE
RISER
QUANTITYQUARRY TILE
RB (RB-)
R THR
QTYQT (QT-)
rTHERMAL RESISTANCE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PAPER TOWEL DISPENSER
POLYVINYL CHLORIDE
REFRIGERATOR
REQUIRED
REFERENCE
ROOF DRAINRECESSED
RECEPTION
REQREINFREFR
RCP
RE
RDREC
RCPTN
RIGHT OF WAY
ROOMRIGHT HAND
ROOFINGREVISION
ROROW
RH
RFG
RM
RF (RF-)
REVRESIL RESILIENT
ROUGH OPENING
REFLECTED CEILING PLAN
RESILIENT FLOORING
REINFORCE, REINFORCING
FIRE HYDRANT
FOUNDATIONFLOOR DRAIN
FABRICATE(D)
FIRE EXTINGUISHER CABINET
FIRE ALARM CONTROL PANEL
FIRE EXTINGUISHER
FLEXIBLE
FLUORESCENTFLOOR, FLOORING
FINISH(ED)FIRE HOSE RACK
FLASHINGFIXTURE
FINISHED OPENING
FIRE HOSE VALVE CABINETFIRE HOSE CABINET
FEC
FH
FDTN
FACP
FD
FABR
FE
FLEX
FLUORFO
FLR (FLR_)
FHVCFHRFIN
FLASHFIXT
FHC
FURRING
FIRE PROTECTION
FIRE RETARDANT
FOOT (FEET)FOOTING
TREATED WOOD
FINNED TUBE RADIATIONFURNISH, FURNITURE
FUTURE
FTR
FURGFURN
FP
FRTW
FTFTG
FUT
FAB (FAB-) FABRIC
PROJECTION SCREENPROJ SCRN
MVBL MOVABLE
ABBREVIATIONS WHEN USED IN COMPOSITION MAY INCLUDE PERIODS FOR CLARIFICATION
MATERIALS
SHEET NUMBER
SYMBOLS LEGEND
ABBREVIATIONS LEGEND
CATEGORY NUMBERDISCIPLINE LETTER
GENERAL NOTES
ABOVE FLOOR REFERENCE ELEV.AFREFINISHED FLOORFF
BLK BLOCK
(EQUIP_)
GLAZED WALL TILEGWT
GLAZED STRUCTURAL UNITGSU
HIGH DENSITY FIBERBOARDHDF
LATITUDE, LATITUDINALLAT
N/A NOT APPLICABLE
PC PRE-CAST
REVEALRVL
URINALUR
1. NOTES APPEAR ON VARIOUS DRAWINGS FOR DIFFERENT SYSTEMS AND MATERIALS. REVIEW ALL SHEETS AND APPLYNOTES TO RELATED BUILDING COMPONENTS.
2. REFER TO COMPLETE SET OF ISSUED CONTRACT DOCUMENTS FOR OTHER APPLICABLE NOTES, ABBREVIATIONS, ANDSYMBOLS.
3. WHERE MATERIALS ARE APPLIED TO, OR ARE IN DIRECT CONTACT WITH WORK INSTALLED BY ANOTHERSUBCONTRACTOR, COMMENCEMENT OF WORK IMPLIES ACCEPTANCE OF THE SUBSTRATE AS SUITABLE FOR THEAPPLICATION INTENDED.
4. ISOLATE DISSIMILAR METALS TO PREVENT GALVANIC CORROSION.
5. PARTITION TYPES AND FIRE RESISTIVE RATINGS INDICATED ON A WALL ARE TO BE CONTINUOUS FOR THE LENGTHAND HEIGHT OF A PARTITION.
6. OPENINGS IN RATED WALL, FLOOR, CEILING AND ROOF ASSEMBLIES SHALL BE SEALED WITH PENETRATION SEALANTSYSTEMS MEETING OR EXCEEDING THE REQUIRED FIRE RESISTIVE RATINGS.
7. MAINTAIN THE FIRE RATING OF CONSTRUCTION AROUND CABINETS, PANELS, AND BOXES RECESSED IN FIRE RATEDWALL, FLOOR, AND CEILING ASSEMBLIES.
8. PROVIDE CONTINUOUS PERIMETER FIRE SAFING BETWEEN FLOORS AND COORDINATE THE INSTALLATION WITH THEEXTERIOR WALL. FIRE RATING OF SAFING SHALL MATCH FIRE RATING OF FLOOR CONSTRUCTION.
9. DO NOT SCALE THE DRAWINGS.
10. FIELD MEASURE AND CONFIRM DIMENSIONS FOR OWNER PROVIDED EQUIPMENT AND FURNISHINGS.
11. PROVIDE STIFFENERS, BRACING, BACKING PLATES AND BLOCKING REQUIRED FOR SECURE INSTALLATION OFTOILET PARTITIONS, DOORS AND DOOR HARDWARE INCLUDING WALL-MOUNTED DOOR STOPS, HANDRAILS,WALL-MOUNTED SHELVES, OPERABLE PARTITIONS, MISCELLANEOUS EQUIPMENT, AND SUSPENDED MECHANICAL ANDELECTRICAL EQUIPMENT.
12. COORDINATE ALL BASE AND HOUSEKEEPING PADS WITH MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT.
13. LOCATE ACCESS PANELS AS INDICATED ON DRAWINGS. FOR ACCESS PANELS NOT SHOWN BUT REQUIRED BYPROVISIONS OF THE CONTRACT DOCUMENTS, LOCATE IN ACCORDANCE WITH APPLICABLE CODES. SUBMIT PROPOSEDLOCATIONS TO THE ARCHITECT FOR REVIEW AND ACCEPTANCE PRIOR TO INSTALLATION.
1. PARTITIONS LOCATED BY DIMENSION STRING ARE DIMENSIONED TO THE FINISHED FACE OF THE WALL UNLESS NOTED OTHERWISE.
2. FOR THE INTERIOR WALL CONSTRUCTION COMPLY WITH IBC 2006 SECTION 803 and 804.
3. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA:
- CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE (SUCH ASA COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THAN STUD WIDTH ON THE LINE.- ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED.- MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR"
1. DOOR OPENINGS ARE DIMENSIONED TO EDGE OF OPENING. IF NOT DIMENSIONED, THE HINGE SIDE OF DOOR JAMBS SHALL BE SPACED 6" FROM THE ADJACENT WALL.
SAND
FILL
STEEL
CONCRETE
TILE UNIT MASONRY
CONTINUOUS WOOD
STRUCTURAL CLAY
FRAMING
ALUMINUM
MASONRY UNITCONCRETE
BRICK MASONRY
CUT STONE
TERRAZZO
COURSE POROUS
GLAZING
GYPSUM WALLBOARD
FINISH WOODWORK
RESILIENT FLOORING
GYPSUM WALLBOARD
PLASTIC LAMINATE
LEAD-LINED
WOOD BLOCKING
WATERPROOFING
CARPETING
BATT INSULATION
RIGID INSULATION
PARTICLE BOARD
PLYWOOD
BOARDACOUSTICAL CEILING
FIREPROOFINGSPRAY-ON
BACKER RODSEALANT AND
GLASS BLOCK
A-220
A - ARCHITECTUREM - MECHANICALE - ELECTRICALP - PLUMBINGS - STRUCTURALF - FIRE SAFETY
001 - GENERAL100 - PLANS12X - ENLARGET PLANS,DETAILS,ELEVATIONS,SECTIONS500 - TYPICAL MOUNTING HEIGHTS & WOODWORK DETAILS600 - REFLECTED CEILING PLANS, DETAILS800 - DOOR, WINDOW SCHEDULE & DETAILS
EQ - MEDICAL EQUIPMENTI - INTERIOR DESIGN
WALL BASEWB
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
09:3
2 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
G-001
INDEX OF DRAWINGS,ABBREVIATIONS AND
SYMBOLS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
INDEX OF DRAWINGS1
SHEET NUMBER SHEET NAME ISSU
E FO
R C
ON
STR
UC
TIO
N
ISSU
E D
ATE
2
ISSU
E D
ATE
3
ISSU
E D
ATE
4
ISSU
E D
ATE
5
ISSU
E D
ATE
6
ISSU
E D
ATE
7
ISSU
E D
ATE
8
00 GeneralG-000 COVER SHEET 9/16/2015G-001 INDEX OF DRAWINGS, ABBREVIATIONS AND SYMBOLS 9/16/2015
01 Life SafetyLS-011 UNIT 1D CODE COMPLIANCE DIAGRAMS 9/16/2015LS-012 UNIT 2B CODE COMPLIANCE DIAGRAMS
02 DemolitionAD-101 UNIT 1D DEMO PLAN & DEMO REFLECTED CEILING PLAN 9/16/2015AD-102 UNIT 2B DEMO PLAN & DEMO REFLECTED CEILING PLAN 9/16/2015
03 ArchitecturalA-101 UNIT 1D RENOVATION PLAN 9/16/2015A-101.1 UNIT 1D SIGNAGE PLAN 9/16/2015A-102 UNIT 2B RENOVATION PLAN 9/16/2015A-102.1 UNIT 2B SIGNAGE PLAN 9/16/2015A-121 UNIT 1D REFLECTED CEILING PLAN AND DETAILS 9/16/2015A-122 UNIT 2B REFLECTED CEILING PLAN AND DETAILS 9/16/2015A-401 ENLARGED FLOOR PLANS & ELEVATIONS 9/16/2015A-420 INTERIOR ELEVATIONS 9/16/2015A-421 INTERIOR ELEVATIONS & TYPICAL MOUNTING HEIGHTS 9/16/2015A-540 MILLWORK SECTIONS & DETAILS 9/16/2015A-541 MILLWORK SECTIONS & DETAILS 9/16/2015A-610 DOOR, WINDOW SCHEDULE AND DETAILS 9/16/2015
04 InteriorI-201 1D INTERIOR FINISH PLAN 9/16/2015I-202 2B INTERIOR FINISH PLAN 9/16/2015I-210 1D INTERIOR FLOOR PATTERN PLAN 9/16/2015I-211 2B INTERIOR FLOOR PATTERN PLAN 9/16/2015
07 ElectricalE-001 ELECTRICAL LEGEND, SYMBOLS AND ABBREVIATIONS 9/16/2015E-002 LUMINAIRE SCHEDULES 9/16/2015E-101-1D ELECTRICAL LIGHTING PLAN AREA 1D 9/16/2015E-102-2B ELECTRICAL LIGHTING PLAN AREA 2B 9/16/2015E-201-1D ELECTRICAL POWER PLAN AREA 1D 9/16/2015E-202-2B ELECTRICAL POWER PLAN AREA 2B 9/16/2015E-301-1D ELECTRICAL FIRE ALARM PLAN AREA 1D 9/16/2015E-302-2B ELECTRICAL FIRE ALARM PLAN AREA 2B 9/16/2015
08 PlumbingP001 PLUMBING LEGEND, GENERAL NOTES, AND SPECIFICATIONS 9/16/2015P101-D1 PLUMBING DEMOLITION FIRST FLOOR AREA D 9/16/2015P102-B2 PLUMBING DEMOLITION SECOND FLOOR AREA B 9/16/2015P201-D1 PLUMBING RENOVATION FIRST FLOOR AREA D 9/16/2015P202-B2 PLUMBING RENOVATION SECOND FLOOR AREA B 9/16/2015P800 PLUMBING DETAILS 9/16/2015
10 Fire ProtectionFP101-D1 FIRE PROTECTION FIRST FLOOR AREA D 9/16/2015FP102-B2 FIRE PROTECTION SECOND FLOOR AREA B 9/16/2015
No. Description Date
PATIENT ROOM1-D30
PATIENT ROOM1-D29
PATIENT ROOM1-D28
PATIENT ROOM1-D21
PATIENT ROOM1-D20
PATIENT ROOM1-D19
PATIENT ROOM1-D31
COMMON AREA1-H07
COMMON AREA1-H07
PATIENT ROOM1-D18
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
CHART ROOM1-D37
GAME ROOM1-D11
CLASSROOM1-D06
CLASSROOM1-D06
OFFICE1-D04
OFFICE1-D02
OFFICE1-D01
OFFICE1-D03
OFFICE1-D05
COMPUTER ROOM1-D07
GROUP ROOM1-D15
SECLUSION1-D14
10'-9
1/2
"6'-
4"
4
4
44
4
4
4
4
4
4
4
46
5
5
5
5
5
5
55
5
5
5
5
5
55
777
777
13
13
23
1313
5'-2
1/2"
7'-10
"
3131
31
31
31
31
31 31 31 31 31
31
31
7777
23
121231
MULTI-PURPOSE
1-D12
3535
55
5
5
5
11
3131 4
31 31 31
31
LAUNDRY ROOM1-D13
31
46
51
GENERAL DEMOLITION NOTES:
01. VERIFY EXISTING, BUILDING CONDITIONS AND DIMENSIONS IN FIELD PRIORTO BIDDING. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT OF ANYDISCREPANCIES PRIOR TO BIDDING.
02. WARNING - MANY ROOMS HAVE DOUBLE EXISTING CEILINGS; DRYWALL SUB-CEILINGS TOREMAIN. VERIFY WITH THE OWNER THE AREA DURING THE INITIAL WALK-THRU.
03. CLAIMS FOR ADDITIONAL COST OR TIME DUE TO EXISTING CONDITIONS THATCOULD HAVE BEEN REASONABLY ANTICIPATED DURING A SITE VISIT BY THECONTRACTOR PRIOR TO BIDDING WILL NOT BE APPROVED.
04. PROTECT EXISTING FINISHES DURING CONSTRUCTION TOPREVENT DAMAGE. REPAIR OR REPLACE DAMAGED MATERIALS AND FINISHES TOMATCH EXISTING AT NO COST TO THE OWNER.
05. EXISTING AREAS REQUIRING MINOR DEMOLITION OR REPAIR FOR EXECUTION OFWORK SHALL BE REPAIRED TO MATCH EXISTING ADJACENT MATERIALS, UNLESSNOTED OTHERWISE.
06. CONTRACTOR TO VERIFY LOCATION OF ALL ELECTRICAL SWITCHES, OUTLETS,GRILLES, CLEAN - OUTS, COVER PLATES, ACCESS DOORS, LIGHTS, EXIT LIGHTS,SPEAKERS, CAMERAS AND FIRE STROBES AND OTHER EQUIPMENT AND DEVICESTHAT MAY CONFLICT WITH THE RENOVATION AND NEW CONSTRUCTIONCEILINGS PRIOR TO COMMENCEMENT OF WORK.
07. DO NOT DAMAGE CASEWORK NOT DESIGNATED TO BE RELOCATED. THISCASEWORK SHALL REMAIN THE PROPERTY OF THE OWNER DURING THEDEMOLITION. NEW CONSTRUCTION SHALL HAVE HARD TYPE PROTECTION.COORDINATE WITH OWNER.
09. ALL DEVICES MOUNTED WITHIN THE CEILING OF DEMOLISHED AREAS SHALLBE REMOVED AND SALVAGED FOR RE-USE OR TURN OVER TO THE OWNER.
10. REUSE OF SALVAGE ITEMS SHALL BE CONSISTENT WITH INSTRUCTION IN OTHER AREAS OF THECONTRACT DOCUMENTS.
11. PATCH AND REPAIR ALL FLOORS AND WALLS IN THE UNIT RELATED TO THE UNDER FLOORPLUMBING WORK
12. SAW CUT METHOD UTILIZATION INTO THE SELECTIVE DEMOLITION SPECIFICATION.
13. REFER TO HCPC's INTERIM LIFE SAFETY MEASURES (ILSM) AND SPECIAL CONDITIONS.
14. REMOVE ALL CARPET FROM WALLS IN UNIT. PATCH WALLS AS NECESSARY TO RECEIVE NEWFINISH.
15. CEILING - BASE PRICING: REMOVE ALL EXISTING GRID CEILINGS AND TILE WHERE NOTED.LEAVE EXISTING HARD CEILINGS. REPLACE LIGHT FIXTURES THROUGHOUT.
16. DOOR - BASE PRICING: REMOVE DOORS AT PATIENT ROOMS THAT SWING IN AND RELOCATE TOSWING OUT USING THE EXISTING FRAME IN PLACE. NOTE: SHOULD INCLUDE LABOR TO REPAIRMETAL FRAME AND DOORS AT THE EXISTING HARDWARE LOCATION AND TO REPLACE THEHINGE WITH A NEW PIANO HINGE.
DEMOLITION LEGEND
EXISTING WALL TO REMAINWALL TO BE DEMOLISHED
DOOR TO BE DEMOLISHED
THIS HATCH INDICATES AREA OF EXISTINGCEILING AND LIGHTING TO BE REMOVED,WHILE HATCH SHOWS EXTENSIVE DEMO,REFER & COORDINATE WITH MEPDOCUMENTS ON EXTENT OF DEMO.
2'x2' EXISTING ACOUSTICAL CEILINGPANELS
EXISTING GYPSUM BOARD CEILING
EXISTING CEILING MOUNTED SPEAKER
EXISTING SECURITY CAMERA
EXISTING EXIT LIGHT
EXISTING 1X4 LIGHT FIXTURE
EXISTING 2X4 LIGHT FIXTURE
EXISTING 2X2 LIGHT FIXTURE
EXISTING PARTITION TO REMAIN
LIMIT OF WORK LINE
NOT PART OF SCOPE OF WORK
SCOPE OF WORK
ONLY FISK ELECTRIC TO REMOVE EXISTING CAMERASPRIOR TO DEMOLITION AND STORE DEVICES WITHINHCPC OR REMOTE LOCATION AS COORDINATED WITHOWNER. FISK ELECTRIC TO REINSTALL CAMERAS ATCOMPLETION OF PROJECT
2627
2626
2626
27
27
27
262627
262627 27
262627
262627
262627
2627
262627
3
333
3
3
3
3
3
3
3
33
3 3 3 3
3
262626
15
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
13:3
4 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
AD-101
UNIT 1D DEMO PLAN& DEMO REFLECTED
CEILING PLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 UNIT 1D DEMOLITION PLAN
Keynote Legend
Key Value Keynote Text
3 EXISTING CEILING TO REMAIN, REPLACE EXISTINGLIGHT FIXTURES WITH NEW FIXTURES; RE: MEPDRAWINGS
4 DEMOLISH WALL AND ALL WALL MOUNTEDEQUIPMENT AND UTILITIES
5 REMOVE AND REUSE DOOR, HARDWARE ANDFRAME
7 DEMOLISH ALL FIXTURES11 REMOVE EXISTING NURSE STATION. DISPOSAL TO
BE COORDINATED WITH OWNER.12 REMOVE ALL WALL MOUNTED ITEMS, STORE FOR
REUSE13 REMOVE MILLWORK AND SINK; CAP FOR NEW SINK
AND PREPARE WALL TO RECEIVE NEW MILLWORKOR FINISH AS SPECIFIED
15 REMOVE EXISTING LAY IN CEILING AND GRIDLEAVING EXISTING DRYWALL CEILING ABOVE LAYIN CEILING. ALL LIGHT FIXTURES AND CEILINGMOUNTED DEVICES SHOULD BE REMOVED ANDRELOCATED/REPLACED PER MEP DRAWINGS.MATCH THE NEW CEILING GRID TO THE EXISTINGGRIDS HEIGHT.
23 DEMOLISH COUNTERTOP AND CABINETRY26 REMOVE EXISTING LIGHT FIXTURE. TURN OVER TO
OWNER FOR RE-USE.27 REMOVE ELEC/DATA BACK TO CEILING TO RUN IN
NEW RACEWAY (SURFACE)31 REMOVE EXISTING FLOORING AND BASE. PREP
FOR NEW FLOORING AND BASE.35 REMOVE TILE BACK TO WATER RESISTANT
SUBSTRATE, PREP FOR NEW FINISH.46 CREATE OPENING FOR NEW WINDOW
INSTALLATION51 PROVIDE TRENCH IN EXISTING FLOOR SLAB
LARGE ENOUGH TO ACCOMODATE CONDUITSHOLDING 8 EA CAT-6 CABLING; TRENCH TO RUNFROM EXISTING PARTITION TO LOCATION OF NEWNURSE STATION; COORDINATE FINAL SIZE ANDLOCATION IN FIELD WITH OWNER AND WITHEXISTING CONDITIONS.
1/8" = 1'-0"2 UNIT 1D REFLECTED CEILING DEMOLITION PLAN
No. Description Date
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
OFFICE2-B56
SECLUSION ROOM2-B54
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
GROUP ROOM2-B51
WORK LOUNGE2-B52
PATIENT ROOM2-B80
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
PATIENT ROOM2-B73
55
5
5
5 5
5 5
5
5
5 55
5
5
5
5
5
5
4
4 4 4
4
44
7
777
77
777
7777
7777
13
13
1313
23
23
3131
31
31
31
31
31
31 31 31 31 31 31
31
31
31
31
31
STORAGE2-B57
31 31
12
5 5
32
27
2323
23
8' - 4
"5'
- 2 1
/2"
3535
11
14
31 31
31
31
31
31 31
31
5246
52
GENERAL DEMOLITION NOTES:
01. VERIFY EXISTING, BUILDING CONDITIONS AND DIMENSIONS IN FIELD PRIORTO BIDDING. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT OF ANYDISCREPANCIES PRIOR TO BIDDING.
02. WARNING - MANY ROOMS HAVE DOUBLE EXISTING CEILINGS; DRYWALL SUB-CEILINGS TOREMAIN. VERIFY WITH THE OWNER THE AREA DURING THE INITIAL WALK-THRU.
03. CLAIMS FOR ADDITIONAL COST OR TIME DUE TO EXISTING CONDITIONS THATCOULD HAVE BEEN REASONABLY ANTICIPATED DURING A SITE VISIT BY THECONTRACTOR PRIOR TO BIDDING WILL NOT BE APPROVED.
04. PROTECT EXISTING FINISHES DURING CONSTRUCTION TOPREVENT DAMAGE. REPAIR OR REPLACE DAMAGED MATERIALS AND FINISHES TOMATCH EXISTING AT NO COST TO THE OWNER.
05. EXISTING AREAS REQUIRING MINOR DEMOLITION OR REPAIR FOR EXECUTION OFWORK SHALL BE REPAIRED TO MATCH EXISTING ADJACENT MATERIALS, UNLESSNOTED OTHERWISE.
06. CONTRACTOR TO VERIFY LOCATION OF ALL ELECTRICAL SWITCHES, OUTLETS,GRILLES, CLEAN - OUTS, COVER PLATES, ACCESS DOORS, LIGHTS, EXIT LIGHTS,SPEAKERS, CAMERAS AND FIRE STROBES AND OTHER EQUIPMENT AND DEVICESTHAT MAY CONFLICT WITH THE RENOVATION AND NEW CONSTRUCTIONCEILINGS PRIOR TO COMMENCEMENT OF WORK.
07. DO NOT DAMAGE CASEWORK NOT DESIGNATED TO BE RELOCATED. THISCASEWORK SHALL REMAIN THE PROPERTY OF THE OWNER DURING THEDEMOLITION. NEW CONSTRUCTION SHALL HAVE HARD TYPE PROTECTION.COORDINATE WITH OWNER.
09. ALL DEVICES MOUNTED WITHIN THE CEILING OF DEMOLISHED AREAS SHALLBE REMOVED AND SALVAGED FOR RE-USE OR TURN OVER TO THE OWNER.
10. REUSE OF SALVAGE ITEMS SHALL BE CONSISTENT WITH INSTRUCTION IN OTHER AREAS OF THECONTRACT DOCUMENTS.
11. PATCH AND REPAIR ALL FLOORS AND WALLS IN THE UNIT RELATED TO THE UNDER FLOORPLUMBING WORK
12. SAW CUT METHOD UTILIZATION INTO THE SELECTIVE DEMOLITION SPECIFICATION.
13. REFER TO HCPC's INTERIM LIFE SAFETY MEASURES (ILSM) AND SPECIAL CONDITIONS.
14. REMOVE ALL CARPET FROM WALLS IN UNIT. PATCH WALLS AS NECESSARY TO RECEIVE NEWFINISH.
15. CEILING - BASE PRICING: REMOVE ALL EXISTING GRID CEILINGS AND TILE WHERE NOTED.LEAVE EXISTING HARD CEILINGS. REPLACE LIGHT FIXTURES THROUGHOUT.
16. DOOR - BASE PRICING: REMOVE DOORS AT PATIENT ROOMS THAT SWING IN AND RELOCATE TOSWING OUT USING THE EXISTING FRAME IN PLACE. NOTE: SHOULD INCLUDE LABOR TO REPAIRMETAL FRAME AND DOORS AT THE EXISTING HARDWARE LOCATION AND TO REPLACE THEHINGE WITH A NEW PIANO HINGE.
DEMOLITION LEGEND
EXISTING WALL TO REMAINWALL TO BE DEMOLISHED
DOOR TO BE DEMOLISHED
THIS HATCH INDICATES AREA OF EXISTINGCEILING AND LIGHTING TO BE REMOVED,WHILE HATCH SHOWS EXTENSIVE DEMO,REFER & COORDINATE WITH MEPDOCUMENTS ON EXTENT OF DEMO.
2'x2' EXISTING ACOUSTICAL CEILINGPANELS
EXISTING GYPSUM BOARD CEILING
EXISTING CEILING MOUNTED SPEAKER
EXISTING SECURITY CAMERA
EXISTING EXIT LIGHT
EXISTING 1X4 LIGHT FIXTURE
EXISTING 2X4 LIGHT FIXTURE
EXISTING 2X2 LIGHT FIXTURE
EXISTING PARTITION TO REMAIN
LIMIT OF WORK LINE
NOT PART OF SCOPE OF WORK
SCOPE OF WORK
ONLY FISK ELECTRIC TO REMOVE EXISTING CAMERASPRIOR TO DEMOLITION AND STORE DEVICES WITHINHCPC OR REMOTE LOCATION AS COORDINATED WITHOWNER. FISK ELECTRIC TO REINSTALL CAMERAS ATCOMPLETION OF PROJECT
2627
26
26
26
26
2626
27
27
27
262627
262627
262627
262627
262627
262627
262627
PATIENT ROOM2-B80
2-OSOA 2-EL6OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
GROUP ROOM2-B51
WORK LOUNGE2-B52
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
COMMON AREA2-H1
SECLUSION ROOM2-B54
OFFICE2-B56
2-B74RESTROOM
PATIENT ROOM2-B73
2-OSOOD
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
RESTROOM2-B67
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
Room
2-H10
2-B43
RESTROOM2-B77
RESTROOM2-B81
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
3
3
3
3
3
3
3 3 3 3 3
327
2626
3
3
3
3
3
3
3
3
3
3
3
15
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
09:0
0 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
AD-102
UNIT 2B DEMO PLAN& DEMO REFLECTED
CEILING PLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 UNIT 2B DEMOLITION PLAN
Keynote Legend
Key Value Keynote Text
3 EXISTING CEILING TO REMAIN, REPLACE EXISTINGLIGHT FIXTURES WITH NEW FIXTURES; RE: MEPDRAWINGS
4 DEMOLISH WALL AND ALL WALL MOUNTEDEQUIPMENT AND UTILITIES
5 REMOVE AND REUSE DOOR, HARDWARE ANDFRAME
7 DEMOLISH ALL FIXTURES11 REMOVE EXISTING NURSE STATION. DISPOSAL TO
BE COORDINATED WITH OWNER.12 REMOVE ALL WALL MOUNTED ITEMS, STORE FOR
REUSE13 REMOVE MILLWORK AND SINK; CAP FOR NEW SINK
AND PREPARE WALL TO RECEIVE NEW MILLWORKOR FINISH AS SPECIFIED
14 DEMOLISH EXISTING NOURISHMENT STATION15 REMOVE EXISTING LAY IN CEILING AND GRID
LEAVING EXISTING DRYWALL CEILING ABOVE LAYIN CEILING. ALL LIGHT FIXTURES AND CEILINGMOUNTED DEVICES SHOULD BE REMOVED ANDRELOCATED/REPLACED PER MEP DRAWINGS.MATCH THE NEW CEILING GRID TO THE EXISTINGGRIDS HEIGHT.
23 DEMOLISH COUNTERTOP AND CABINETRY26 REMOVE EXISTING LIGHT FIXTURE. TURN OVER TO
OWNER FOR RE-USE.27 REMOVE ELEC/DATA BACK TO CEILING TO RUN IN
NEW RACEWAY (SURFACE)31 REMOVE EXISTING FLOORING AND BASE. PREP
FOR NEW FLOORING AND BASE.32 REMOVE EXISTING WALL DRYWALL/PLASTER BACK
TO STUDS35 REMOVE TILE BACK TO WATER RESISTANT
SUBSTRATE, PREP FOR NEW FINISH.46 CREATE OPENING FOR NEW WINDOW
INSTALLATION52 CORE TWO HOLES IN EXISTING FLOOR SLAB
LARGE ENOUGH TO ACCOMODATE CONDUITSHOLDING 8 EA CAT-6 CABLING; COORDINATE FINALSIZE AND LOCATION IN FIELD WITH OWNER ANDWITH EXISTING CONDITIONS.
1/8" = 1'-0"2 UNIT 2B DEMOLITION REFLECTED CEILING PLAN
No. Description Date
REF.
A-420
15
A-420 6
A-420
7
A-4012
A-4014
A-4013
A-4011
PATIENT ROOM1-D30
PATIENT ROOM1-D29
PATIENT ROOM1-D28
PATIENT ROOM1-D21 PATIENT ROOM
1-D20PATIENT ROOM
1-D19
1-E28
1-D00
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14
GROUP ROOM1-D15
PATIENT ROOM1-D18
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36
CHART ROOM1-D37
1-D40
1-D42
1-D43
1-D44
1-D46 1-D47
1-D481-D49
1-D50
1-H06
STAIR1-0S0F
RESTROOM1-D35A
RESTROOM1-D32
COMMON AREA1-H07
A-420 10
A-420
11
A-42010
Sim
A-421 2A-420
17
A-420 14
1-0S0F-1
1-D40
1-D42
1-D44
1-D46
1-D48 1-D49
1-D13 1-E281-D11
1-D12 1-D14 1-D15
1-E100B
1-D50-2
1-D41
1-0S0F-21-H07-1
1-D35A
1-D39
1-D43
1-D45
1-D47
1-D00 1-D50-1
1-H03-1
1-D25
1-D26 1-D23
1-D24
1-D18
1-D191-D201-D211-D281-D291-D30
1-D31
1-D32
1-D33
1-D34
1-D35
A-421
A-420
11 Sim
18
A-421
1
A41A33
A33
A41 A41
A41
W2
W2
A41
A33 A33
A41
17
1717
1717
1717
1717 1717 1717 17171717
1717
1717
20
A-421 8
A-420 5
12
1-D371-D36
OFFICE1-D01
38
A-421 10
15
24
24 A-421
12 Sim
A-420 20
A-420 21
2' - 6"
4' - 0
"
2' - 8
"
4' - 0
"2'
- 8"
A-54013
A41
W2 W2 W2
2'-0 1/2"16
54
55
57575757
1. REFER TO SHEET A-001 FOR ADDITIONAL GENERAL NOTES.
2. MOVE EXISTING ELECTRICAL AND MECHANICAL FIXTURES IF NEEDED. V.I.F.AND COORDINATE WITH ARCHITECT.
3. NEW GRID TO MATCH EXISTING CEILING HEIGHT.
4. PATCH AND REPAIR HOWLS ON THE WALL ATTACHED TO THE NEW WALL.
5. ALL NOURISHMENT APPLIANCES ARE OWNER FURNISHED, CONTRACTORINSTALLED.
6. COORDINATE SHOP DRAWINGS WITH APPLIANCES AND MEP DRAWINGS.
GENERAL FLOOR PLAN NOTES
ELEVATION TAG
DOOR DESIGNATION
WINDOW DESIGNATION
PARTITION TYPE
REVISION NUMBER
ENLARGED FLOOR PLAN BUBBLE
DETAIL AND VERTICAL SECTIONS
M1
DIMENSIONS - ALL DIMENSIONS TOFACE OF WALL UNLESS OTHERWISENOTED
BRACKETS - INDICATED EXISTINGDIMENSIONS - CONTRACTOR TO FIELDVERIFY
5'-6 1/256" 7'-3 3/128"
12'-9 7/256"
[ 12'-9 7/256" ]
FLOOR PLAN LEGEND
A101
A101
1
AX.XX
1
1
A5.00
1
A6.00
NEW PARTITION
EXISTING PARTITION
SHOWER CURTAIN
CONTRACTOR FURNISHED EQUIPMENT/ITEM
OWNER FURNISHED EQUIPMENT/ITEM
NOT IN SCOPE OF WORK
SCOPE OF WORK
DOORSTOPS
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
05:4
7 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-101
UNIT 1D RENOVATIONPLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 First Floor - Unit 1D
Keynote Legend
Key Value Keynote Text
17 HEAD WALL PANEL20 NOURISHMENT STATION RE: PLUMBING24 TV CABINET38 PROVIDE NEW SECURE MOUNT FOR EXISTING
PUNCHING BAG; SECURE TO CEILING WITHTHRESHOLD EYE-BOLT AND SUSPEND FROM ABOVECEILING WITH UNISTRUT FRAMING TIED TOSTRUCTURE.
54 FILL IN TRENCH WITH GROUT AND PREPARE TORECEIVE NEW FLOORING FINISH
55 WALLTALKERS NU-VU-RITE WALLCOVERING57 WALL PADDING; MARATHON ENGINEERING
CORPORATION, GOLD MEDAL SAFETY PADDING
No. Description Date
REF.
1-E28
Room
1-D00OFFICE1-D01
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14 GROUP ROOM
1-D15
PATIENT ROOM1-D18
PATIENT ROOM1-D19
PATIENT ROOM1-D20PATIENT ROOM
1-D21
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D28
PATIENT ROOM1-D29
PATIENT ROOM1-D30
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35 MEDICINE ROOM
1-D36
CHART ROOM1-D37
1-D39
1-D40
Room
1-D42
1-D43
1-D441-D45
1-D46 1-D47
1-D481-D49
1-D50
1-H06
STAIR1-0S0F
RESTROOM1-D35A
Room
RESTROOM1-D32
COMMON AREA1-H07
12
43
6
5
7
8
9 10
111213
14
15
16
17
18
19
20
2221 23
24
25
27
26
28 29 30
31
32
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
05:5
8 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-101.1
UNIT 1D SIGNAGEPLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 Unit 1D Signage Plan
NOTE: REFER TO ELEVATIONS FOR MOUNTING HEIGHTS. SIGNS 21 AND 22 MUST BE MOUNTED ONE ABOVETHE OTHER WITHIN ACCEPTABLE ADA MOUNTING HEIGHTS RE: 11/A-421
V.I.F. WALL SPACES FOR SIGN WIDTHS. NOTIFY ARCHITECT OF SIGNS NEEDING TO BE SHORTENED TO FITAT DESIGNATED LOCATION.
No. Description Date
REF
.
A-4014
Sim
PATIENT ROOM2-B80
2-OSOA 2-EL6OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
GROUP ROOM2-B51
WORK LOUNGE2-B52
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
COMMON AREA2-H1
SECLUSION ROOM2-B54
OFFICE2-B56
2-B74RESTROOM
PATIENT ROOM2-B73
2-OSOOD
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
RESTROOM2-B67
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
A-421
5
2-B80
1-H12
2-B78
2-B76
2-B75
2-B722-B63
2-B62
2-B60
RESTROOM2-B77
A-4011
Sim
A-42016A-420 16
Sim
RESTROOM2-B81
17
1717
1717
1717
17171717
1717
17171717 1717
1717
1717
19
20
21
22
A-420
10 Sim
A-420
10 Sim
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
A-421 3 A-421 4
A-421
6
7
A-421
9
2-B81
2-B53
2-B54 2-B56
EH1-H12-1
2-B44
2-B46
2-B45
2-B47
2-B48
2-B502-B49
2-B5
5
2-B5
7
2-H10
2-OSOOD
2-B65
2-B662-B68
2-B67
2-B52
2-B73
2-B71 2-B70 2-B61
2-B74
2-B51
2-B77
A-420 7
Sim
A-420
6
Sim
4' - 0
"2'
- 8"
4' - 0
"2'
- 8"
49
49
2' - 4"
W2 W2 W2
1. REFER TO SHEET A-001 FOR ADDITIONAL GENERAL NOTES.
2. MOVE EXISTING ELECTRICAL AND MECHANICAL FIXTURES IF NEEDED. V.I.F.AND COORDINATE WITH ARCHITECT.
3. NEW GRID TO MATCH EXISTING CEILING HEIGHT.
4. PATCH AND REPAIR HOWLS ON THE WALL ATTACHED TO THE NEW WALL.
5. ALL NOURISHMENT APPLIANCES ARE OWNER FURNISHED, CONTRACTORINSTALLED.
6. COORDINATE SHOP DRAWINGS WITH APPLIANCES AND MEP DRAWINGS.
GENERAL FLOOR PLAN NOTES
ELEVATION TAG
DOOR DESIGNATION
WINDOW DESIGNATION
PARTITION TYPE
REVISION NUMBER
ENLARGED FLOOR PLAN BUBBLE
DETAIL AND VERTICAL SECTIONS
M1
DIMENSIONS - ALL DIMENSIONS TOFACE OF WALL UNLESS OTHERWISENOTED
BRACKETS - INDICATED EXISTINGDIMENSIONS - CONTRACTOR TO FIELDVERIFY
5'-6 1/256" 7'-3 3/128"
12'-9 7/256"
[ 12'-9 7/256" ]
FLOOR PLAN LEGEND
A101
A101
1
AX.XX
1
1
A5.00
1
A6.00
NEW PARTITION
EXISTING PARTITION
SHOWER CURTAIN
CONTRACTOR FURNISHED EQUIPMENT/ITEM
OWNER FURNISHED EQUIPMENT/ITEM
NOT IN SCOPE OF WORK
SCOPE OF WORK
DOORSTOPS
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
06:2
3 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-102
UNIT 2B RENOVATIONPLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 Second Floor - Unit 2B
Keynote Legend
Key Value Keynote Text
17 HEAD WALL PANEL19 NURSE STATION20 NOURISHMENT STATION RE: PLUMBING21 LIBRARY WALL22 HEARTH WALL49 PROXIMITY #CWT-28 COMPUTER STATIONS
No. Description Date
REF
.
PATIENT ROOM2-B80
2-OSOA 2-EL6OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
GROUP ROOM2-B51
WORK LOUNGE2-B52
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
2-B81
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
COMMON AREA2-H1
SECLUSION ROOM2-B54
OFFICE2-B56
2-B74RESTROOM
PATIENT ROOM2-B73
2-OSOOD
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
RESTROOM2-B67
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
Room
2-H10
2-B43
RESTROOM2-B77
RESTROOM2-B81
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
12
4 3
6
5
8
7
9
10
12
1314
1516
17
19
20
21
232224
25
26
28
27
29 30
32
33
11
31
18
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
06:4
3 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-102.1
UNIT 2B SIGNAGEPLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 Unit 2B Signage Plan
No. Description Date
1-D00OFFICE1-D01
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14
GROUP ROOM1-D15
PATIENT ROOM1-D18
PATIENT ROOM1-D19
PATIENT ROOM1-D20
PATIENT ROOM1-D21
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D28
PATIENT ROOM1-D29
PATIENT ROOM1-D30
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36CHART ROOM
1-D37
1-D40
Room
1-D42
1-D44
1-D46
1-D48
1-D50
1-H06
STAIR1-0S0F
RESTROOM1-D35A
RESTROOM1-D32
COMMON AREA1-H07
1
A-121
2
A-122
s
s
s s
s
s s
s s
ss
39
38
s
s s
1' - 4"1' - 4"
1' - 6
"1'
- 6"
1' - 6
"
48
50
REFLECTED CEILING PLAN LEGEND
2X4 FLORESCENT
2X2 FLORESCENT
1 x 4 LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
ES
PS
CEILING DETAIL TAG
SUSPENDED 2' X 2'ACOUSTICAL CEILING SYSTEM(APC)
RETURN AIR GRILLEREFER TO MECHANICAL DRAWINGS FOR ADDITONALINFORMATION
SUPPLY AIR GRILLEREFER TO MECHANICAL DRAWINGS FORADDITIONAL INFORMATION
UNDER COUNTER TASK LIGHTING (N/A)
GYP. BOARD CEILING
EXPOSED STRUCTURE, PAINT ALLITEMS ABOVE CEILING IN OCCUPIEDSPACES
SHOWER DOME LIGHT (BYSHOWER MANUFACTURER).
CEILING HEIGHT DESIGNATION PER AREA.
SUPPLY STRIP DIFFUSER RE: MECHANICAL
SUSPENDED CEMENT PLASTER SOFFIT
1A-###
FLUORESCENT STRIP COVE LIGHTING (N/A)
9'-0" AFF
SPEAKERALL SPEAKERS TO BE ROUTED BACK TOSOURCE; 1-D11, 1-D12, 1-D14 WILL BEROUTED BACK TO 1-D37; 2-B51 AND 2-B54WILL ROUTE BACK TO 2-B52; SPEAKERS INCOMMON AREAS (1-H07 AND 2-H1) WILLROUTH BACK TO RESPECTIVE TVLOCATIONS. CONFIRM ALL ROUTINGLOCATIONS WITH OWNER
SECURITY CAMERA
EXIT LIGHT
WALL MOUNTED LIGHT
THERMOSTAT
CEILING TYPE
ONLY FISK ELECTRIC TO REMOVE EXISTINGCAMERAS PRIOR TO DEMOLITION AND STOREDEVICES WITHIN HCPC OR REMOTE LOCATION ASCOORDINATED WITH OWNER. FISK ELECTRIC TOREINSTALL CAMERA AND COMPLETION OFPROJECT.
S
LINEAR WOOD CEILING
ACOUSTICALCEILING TILE
RE: RCP
RE: RCP
RUNNER AND STUD ATTACHEDTO THE GRIDEXISTING CEILING TO REMAIN
ALUMINUM CEILING TRIM PAINTEDWITH SAME COLOR AS THE WALL
SCHEDULED FINISH
5/8" GYP. BOARD ON BOTH SIDES
3 5/8" METAL STUD
1. THE CONTRACTOR SHALL COMPARE THIS REFLECTED CEILING PLAN WITHINDICATED LECTRICAL LIGHTING PLANS, MECHANICAL SUPPLY, RETURN ANDEXHAUST PLANS. MECHANICAL FIXTURES ARE NOT INDICATED ON THISPLAN, RE: MEP. THE CONTRACTOR SHALL EPORT ANY OMISSIONS ORINCONSISTINCIES TO THE ARCHITECT.
2. SEE ELECTRICAL DRAWINGS FOR THE LOCATIONS OF CEILING MOUNTEDSMOKE DETECTORS, PEAKERS, EXIT SIGNAGE AND FIRE ALARM DEVICES,ETC. ALSO SEE ELECTRICAL FOR LOCATIONS OF WALL MOUNTED EXITLIGHTS.
3. SPRINKLER HEADS ARE NOT SHOWN ON ARCHITECTURAL REFLECTEDCEILING PLANS. CONTRACTOR TO INSTALL SUFFICIENT HEADS IN ALLSPACES TO PROVIDE 100% COVERAGE AS REQUIRED UNDER NFPA 13 ANDOWNERS' INSURANCE COMPANIES' REQUIREMENTS. CENTER ALLSPRINKLER HEADS IN CEILING TILES AND GYPSUM BOARD CEILINGS.
4. CEILING ACCESS PANELS ARE NOT SHOWN ON ARCHITECTURAL REFLECTEDCEILING PLANS. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELSOF TYPE SPECIFIED ARE INSTALLED IN NON-ACCESSIBLE TYPE CEILINGSWHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, ORELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE EQUALTO THE RATING OF THE WALL OR CEILING IN WHICH THEY OCCUR.
5. 18" MINIMUM VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN THEBOTTOM OF THE EXTENDED SPRINKLER HEADS AND THE TOP OF ANYFILES, SHELVING, LOCKERS, ETC.
6. PRE-MANUFACTURED SHOWER UNITS ARE PROVIDED WITH LIGHTFIXTURES (RE: ELECTRICAL FOR CONNECTION.)
7. ALL CEILING ELEMENTS TO BE PLACED IN THE CENTER OF CEILING TILE ORCENTER OF GYP. BOARD CEILING AREA U.N.O.
8. ALL CEILING GRIDS TO BE CENTERED BETWEEN WALLS U.N.O.
9. V.I.F CEILING HEIGHT. ALL ACOUSTICAL CEILINGS TO MATCH EXISTINGCEILING HEIGHT UNLESS NOTED OTHERWISE.
10. SAW CUT AND REMOVE EXISTING SLAB AND FLOOR FINISHES ASREQUIRED TO INSTALL NEW PLUMBING LINES, FLOOR DRAINS, FIXTURESOR ELECTRICAL ITEMS. SPLICE NEW REINFORCING BARS DOWELED INTOEXISTING CONCRETE AND PROVIDE NEW VAPOR RETARDER ANDWATERSTOPS, PATCH WITH A MINIMUM OF 3000 PSI CONCRETE AFTERINSTALLATION OF UTILITIES AND FIXTURES. PREPARE CONCRETE TO RECEIVENEW FINISH.
REFLECTED CEILING PLAN GENERAL NOTES
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
06:5
2 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-121
UNIT 1D REFLECTEDCEILING PLAN AND
DETAILS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"6 UNIT 1D REFLECTED CEILING PLAN
1 1/2" = 1'-0"1 WOOD CEILING DETAIL
3" = 1'-0"3 WALL TO CEILING DETAIL
Keynote Legend
Key Value Keynote Text
38 PROVIDE NEW SECURE MOUNT FOR EXISTINGPUNCHING BAG; SECURE TO CEILING WITH THRESHOLDEYE-BOLT AND SUSPEND FROM ABOVE CEILING WITHUNISTRUT FRAMING TIED TO STRUCTURE.
39 PROJECTOR, OWNER FURNISHED CONTRACTORINSTALLED
48 MOTION SENSORS, RE: MEP SPECS50 EXISTING CAMERA TO BE RELOCATED BY FISK
ELECTRIC IN COORINATION WITH OWNER ANDDRAWINGS.
No. Description Date
PATIENT ROOM2-B73
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
SECLUSION ROOM2-B54
OFFICE2-B56
PATIENT ROOM2-B75
PATIENT ROOM2-B76
PATIENT ROOM2-B78
PATIENT ROOM2-B80
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
2
A-122
Sim
1
A-121
Sim
3
A-122
RESTROOM2-B77
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
GROUP ROOM2-B51
WORK LOUNGE2-B52
RESTROOM2-B67
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
s s
s s
s s
ss
50
s
56
56
56
REFLECTED CEILING PLAN LEGEND
2X4 FLORESCENT
2X2 FLORESCENT
1 x 4 LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
ES
PS
CEILING DETAIL TAG
SUSPENDED 2' X 2'ACOUSTICAL CEILING SYSTEM(APC)
RETURN AIR GRILLEREFER TO MECHANICAL DRAWINGS FOR ADDITONALINFORMATION
SUPPLY AIR GRILLEREFER TO MECHANICAL DRAWINGS FORADDITIONAL INFORMATION
UNDER COUNTER TASK LIGHTING (N/A)
GYP. BOARD CEILING
EXPOSED STRUCTURE, PAINT ALLITEMS ABOVE CEILING IN OCCUPIEDSPACES
SHOWER DOME LIGHT (BYSHOWER MANUFACTURER).
CEILING HEIGHT DESIGNATION PER AREA.
SUPPLY STRIP DIFFUSER RE: MECHANICAL
SUSPENDED CEMENT PLASTER SOFFIT
1A-###
FLUORESCENT STRIP COVE LIGHTING (N/A)
9'-0" AFF
SPEAKERALL SPEAKERS TO BE ROUTED BACK TOSOURCE; 1-D11, 1-D12, 1-D14 WILL BEROUTED BACK TO 1-D37; 2-B51 AND 2-B54WILL ROUTE BACK TO 2-B52; SPEAKERS INCOMMON AREAS (1-H07 AND 2-H1) WILLROUTH BACK TO RESPECTIVE TVLOCATIONS. CONFIRM ALL ROUTINGLOCATIONS WITH OWNER
SECURITY CAMERA
EXIT LIGHT
WALL MOUNTED LIGHT
THERMOSTAT
CEILING TYPE
ONLY FISK ELECTRIC TO REMOVE EXISTINGCAMERAS PRIOR TO DEMOLITION AND STOREDEVICES WITHIN HCPC OR REMOTE LOCATION ASCOORDINATED WITH OWNER. FISK ELECTRIC TOREINSTALL CAMERA AND COMPLETION OFPROJECT.
S
RUNNER AND STUD ATTACHEDTO THE GRIDEXISTING CEILING TO REMAIN
ALUMINUM CEILING TRIM PAINTEDWITH SAME COLOR AS THE WALL
SCHEDULED FINISH
5/8" GYP. BOARD ON BOTH SIDES
3 5/8" METAL STUD
PAINTED 5/8" GYP BDON 2 1/2" MTL STUDS
PAINT ALL EXPOSEDELEMENTS ABOVECEILING WHERECEILING VOIDOCCURS
2'x2' ACOUSTICALCEILING
RE: RCP
RE: RCP
V.I.F
.1'-
10"
LINEAR WOOD CEILING
RE: RCP
SCHEDULEDMILWORK
1. THE CONTRACTOR SHALL COMPARE THIS REFLECTED CEILING PLAN WITHINDICATED LECTRICAL LIGHTING PLANS, MECHANICAL SUPPLY, RETURN ANDEXHAUST PLANS. MECHANICAL FIXTURES ARE NOT INDICATED ON THISPLAN, RE: MEP. THE CONTRACTOR SHALL EPORT ANY OMISSIONS ORINCONSISTINCIES TO THE ARCHITECT.
2. SEE ELECTRICAL DRAWINGS FOR THE LOCATIONS OF CEILING MOUNTEDSMOKE DETECTORS, PEAKERS, EXIT SIGNAGE AND FIRE ALARM DEVICES,ETC. ALSO SEE ELECTRICAL FOR LOCATIONS OF WALL MOUNTED EXITLIGHTS.
3. SPRINKLER HEADS ARE NOT SHOWN ON ARCHITECTURAL REFLECTEDCEILING PLANS. CONTRACTOR TO INSTALL SUFFICIENT HEADS IN ALLSPACES TO PROVIDE 100% COVERAGE AS REQUIRED UNDER NFPA 13 ANDOWNERS' INSURANCE COMPANIES' REQUIREMENTS. CENTER ALLSPRINKLER HEADS IN CEILING TILES AND GYPSUM BOARD CEILINGS.
4. CEILING ACCESS PANELS ARE NOT SHOWN ON ARCHITECTURAL REFLECTEDCEILING PLANS. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELSOF TYPE SPECIFIED ARE INSTALLED IN NON-ACCESSIBLE TYPE CEILINGSWHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, ORELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE EQUALTO THE RATING OF THE WALL OR CEILING IN WHICH THEY OCCUR.
5. 18" MINIMUM VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN THEBOTTOM OF THE EXTENDED SPRINKLER HEADS AND THE TOP OF ANYFILES, SHELVING, LOCKERS, ETC.
6. PRE-MANUFACTURED SHOWER UNITS ARE PROVIDED WITH LIGHTFIXTURES (RE: ELECTRICAL FOR CONNECTION.)
7. ALL CEILING ELEMENTS TO BE PLACED IN THE CENTER OF CEILING TILE ORCENTER OF GYP. BOARD CEILING AREA U.N.O.
8. ALL CEILING GRIDS TO BE CENTERED BETWEEN WALLS U.N.O.
9. V.I.F CEILING HEIGHT. ALL ACOUSTICAL CEILINGS TO MATCH EXISTINGCEILING HEIGHT UNLESS NOTED OTHERWISE.
10. SAW CUT AND REMOVE EXISTING SLAB AND FLOOR FINISHES ASREQUIRED TO INSTALL NEW PLUMBING LINES, FLOOR DRAINS, FIXTURESOR ELECTRICAL ITEMS. SPLICE NEW REINFORCING BARS DOWELED INTOEXISTING CONCRETE AND PROVIDE NEW VAPOR RETARDER ANDWATERSTOPS, PATCH WITH A MINIMUM OF 3000 PSI CONCRETE AFTERINSTALLATION OF UTILITIES AND FIXTURES. PREPARE CONCRETE TO RECEIVENEW FINISH.
REFLECTED CEILING PLAN GENERAL NOTES
PAINTED 5/8" GYP BDON 2 1/2" MTL STUDS
ACOUSTICALCEILING TILE
1' - 0
"
RE: RCP
RE: RCP
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
07:0
8 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-122
UNIT 2B REFLECTEDCEILING PLAN AND
DETAILS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"4 UNIT 2B REFLECTED CEILING PLAN
3" = 1'-0"1 WALL TO CEILING DETAIL
1 1/2" = 1'-0"3 HEARTH WALL CEILING DETAIL
1 1/2" = 1'-0"2 NURSE STATION DETAIL
Keynote Legend
Key Value Keynote Text
50 EXISTING CAMERA TO BE RELOCATED BY FISKELECTRIC IN COORINATION WITH OWNER ANDDRAWINGS.
56 HARD CEILING TO REMAIN. ADD ACOUSTICAL CEILINGBELOW HARD CEILING TO MATCH CEILING HEIGHT OFACT IN ADJACENT ROOM
No. Description Date
8'-6"
1717
25
3' - 4"
3' - 0" 2' - 6" 3' - 0"
2' - 0
"
4" BACKSPLASHSUPPORTBRACKET
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36
CHART ROOM1-D37
RESTROOM1-D35A
A-4202
1
3
4
A-4208
A-401
A-401
A-401
7
5
10
11
3' - 5
"
7'-6"
A-421
2
4' - 3 1/2"1' - 4"
A-401 8
1A-540
2A-540
4A-540
9
5' - 0"
4' - 1
1"
8' - 0"
1' - 1
0"3'
- 6"
3A-540
A-5405
A-5405
Sim
A-5406
2
A-122
8' - 10 1/2"
2' - 6
"3'
- 0"
2' - 6
"
9 1/
2"11
' - 2"
7' - 0 1/2"
ALIG
N
17
SUPPORT BRACKET4" BACKSPLASH
25
A-401
12
53
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
8 1/
2"3'-
5"
A-420
12
13
5'-2
1/2"
A-420
111'
- 6"
1'-4 1/2"
8'-11
"
9'-10
"
3' - 0"
TA9TA2
TA1TA1
TA9
TA2
TA1
TA2
TA9TA1
TA2TA9
6' - 0
"
2' - 0"
TA10TA10
TA10TA10
A-420 19
8' - 6
"
17171717
2525
5' - 0 1/2"
27
3' - 4
"
1' - 3
"
1' - 10"
EQ.
EQ.
2' - 6
"3'
- 0"
3' - 0
"
2' - 0" 4" BACKSPLASH
SUPPORT BRACKET
A-421 8
A-54012
A-54014
TA1
TA2
TA3TA4TA5TA6TA7TA8
TA9TA10
18" X 24" MIRROR- MANUFACURER: ODD BALLINDUSTRIES MFG. CO. INC. MODEL: SP-8
RECESSED TOILET PAPER DISPENSER ,MANUFACTURER: ODDBALL INDUSTRIES
GRAB BARS AT TYPICAL H.C. TOILET STALL
SANITARY NAPKIN DISPENSER
CLOTHES HOOKGRAB BARS AT ACCESSIBLE SHOWER
COMBO PAPER TOWEL DISPENSER/TRASH RECEPTACLE
CLOTHES/ TOWEL HOOK
LABEL DESCRIPTION REMARKS
TOILET ACCESSORIES
NOTE: ALL TOILET ACCESSORIES SHALL BE CONTRACTOR FURNISHED AND INSTALLEDUNLESS NOTED OTHERWISE
1. COORDINATE FINAL LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
2. CONTRACTOR IS TO VERIFY ALL HEIGHTS OF ACCESSORIES TO COMPLY WITH ADA.
3. REFER TO ALL FINISHES AND COLORS IN FINISH SCHEDULE. VERIFY ALL PATTERNS WITH ARCHITECT.
4. ALIGN MIRROR ON CENTER OF LAVATORY.
5. ONE HOOK INSIDE DOOR AT EACH TOILET PARTITION. ONE HOOK INSIDE DOOR AT SINGLE TOILET ROOMS AND ONE HOOK AT EACH SHOWER.
6. REFER TO INTERIOR FINISH LEGEND FOR NURSE STATION FINISHES.
NOTE 5SHOWER/PRIVACY CURTAIN
GRAB BARS AT ALTERNATE ACCESSIBLE TOILET
1A-540
PLAM CLAD COUNTER SURFACECO-1
SCHEDULED BASEPL-2
PL-1
PL-3
53
2A-540
3A-540
PLAM CLAD COUNTERSURFACECO-1
PL-1
PL-3
SCHEDULED BASEPL-2
1' - 0
"2'
- 2"
4"
3' - 6
"
3' - 4
1/2
"
53
PLAM CLADENTRY DOORPL-3
4A-540
PLAM CLAD COUNTER SURFACECO-1
PL-1
PL-3
SCHEDULED BASEPL-2
3' - 2
"
3' - 6
"
53
1A-540
3' - 6
"
2' - 6
"
KNEE SPACE
PLAM CLAD COUNTERCO-1
PL-3
PL-1
PL-3
SCHEDULED BASEPL-2
4"
KNEE SPACE KNEE SPACE
FIXED SHELVING
2A-540
3A-540
EQ.
EQ.
EQ.
4"
SLANTED ELEVATION
KNEE SPACE
EQ. EQ.
2' - 6
"3' - 6
"
PLAM CLAD COUNTER TOPCO-1
SCHEDULED BASEPL-2
PL-3PL-1
PL-3
PLAM CLADENTRY SWINGDOORPL-3
HALF WALLWITHSCHEDULEDFINISH
4"
4" UNDERCUT
EXISTING WALL
SCHEDULED BASE
PLAM CLADCOUNTERTOPCO-1
A-40113
PLAM CLAD ENTRYSWING DOORPL-3
4"
4" UNDERCUT
EXISTING WALL
PLAM CLAD COUNTER TOPCO-1
PL-1
PL-3
FINISH SECTIONS - NURSE STATION(COUNTERTOPS) CORIAN "COTTAGE LINE"CO-1
PL-1 (UPPER FRAME) WILSONART PLASTICLAMINATE "DESERT ZEPHYR" #4841-60
PL-2
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE (OUTSIDE &INSIDE NURSE STATION)
WILSONART #6257 (419) SATIN BRUSHED NATURAL ALUMINUM(OUTSIDE & INSIDE NURSE STATION )
4A-540
FIXED SHELVING
EXISTING WALL
KNEE SPACE
PLAM CLADENTRY DOORPL-3
1' - 0
"2'
- 6"3'
- 6"
CO-1
PL-1
PL-3
PL-2 4"
PLAM CLADENTRY SWINGDOOR 1/4"
1/4" REVEALPAINTED FLATBLACK
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
07:1
8 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-401
ENLARGED FLOORPLANS & ELEVATIONS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/4" = 1'-0"4 TYPICAL SINGLE PATIENT ROOM
1/4" = 1'-0"3 PATIENT ROOM, CHART ROOM, MEDICINE ROOM, AND NURSE STATION 1/4" = 1'-0"1 1D BATHROOM CLUSTER
1/4" = 1'-0"2 TYPICAL ADJACENT PATIENT ROOMS
Keynote Legend
Key Value Keynote Text
17 HEAD WALL PANEL25 DESK/ SHELF COMBO27 REMOVE ELEC/DATA BACK TO CEILING TO RUN IN
NEW RACEWAY (SURFACE)53 PROVIDE A MINIMUM OF 6 BLACK GROMMETS WITH
A 4-1/2" DIAMETER; COORDINATE FINALLOCATIONS WITH OWNER IN FIELD.
1/2" = 1'-0"5 NURSE STATION - EXTERIOR 1/2" = 1'-0"6 NURSE STATION - EXTERIOR
1/2" = 1'-0"7 NURSE STATION - EXTERIOR 1/2" = 1'-0"10 NURSE STATION - INTERIOR
1/2" = 1'-0"11 NURSE STATION-INTERIOR
1/2" = 1'-0"8 NURSE STATION-EXTERIOR 1/2" = 1'-0"9 NURSE STATION-EXTERIOR
1/2" = 1'-0"12 NURSE STATION-INTERIOR 3" = 1'-0"13 NURSE STATION DETAIL
No. Description Date
1 1/2" 2' - 0" 1' - 9"
1 1/
2"
3'-9
1/2"
1'-11
"2'-
8"
4'-7"
7'-1
1/4"
3/4"
10A-540
11A-540
9A-540
8"
3/4"SCRIBE
3/4"
2' - 3 1/2"
3/4" 3/4"
15A-540
INFORMATIONBOARD:
DISPLAYS2GOSKU:BCF3036OB
3 FORM PANELBACKLIT RE:MEP
BLACKBOARDPAINT
15A-541
4'-0"
1 1/
2"
4"2'
-6"
EQ.
EQ.
EQ.
EQ.
4"1"
3/4"
20A-540
19A-540
KNEE SPACE KNEE SPACE
BLACKBOARD PAINT
OWNER FURNISHED REFRIGERATOR
ADJUSTABLE SHELVING
NEW MILLWORK
SLOPED TOPS, TYP.
4"EQ
.EQ
.2'
- 9"
7' - 0
"
EQ.
EQ.
EQ.
EQ.
4' - 3
"
3A-541
2A-541
1A-541
NEW MILLWORK TOREPLACE EXISTING
BULLETIN BOARD
POWER COLUMN/STRIP
SCHEDULED BASE
SLOPED TOPS, TYPICAL
2' - 6
"
2' - 6
"
14A-541
SCHEDULED BASE
SLOPED TOP, TYP.
4"EQ
.EQ
.
2' - 9
"
7' - 0
"1'
- 0"
EQ.
EQ.
EQ.
EQ.
1' - 6
"2'
- 6"
3' - 0
"1'
- 0"
4A-541 POWER COLUMN/STRIP
RE: MEP
SLOPED TOPS, TYP.
NEW DOOR
SCHEDULED BASE
NEW MILLWORK TOREPLACE EXISTING
NEWPLUMBINGFIXTURE TOREPLACEEXISTING RE:PLUMBING
4"
3' - 0"
1' - 0
"5'
- 6"
GBL-1RE: INTERIORFINISHSHEETS
PTP-5RE: INTERIORFINISHSHEETS
PTP-4RE: INTERIORFINISHSHEETS
22A-420
Sim
4' - 6
"1'
- 0"
PTP-5RE: INTERIORFINISHSHEETS
PTP-4RE: INTERIORFINISHSHEETS
PTP-5RE: INTERIOR
FINISH SHEETS
PTP-4RE: INTERIOR
FINISH SHEETS
WB RE: FINISHSHEETS
WB RE: FINISHSHEETS
8A-540
CLEAN LINENSTORAGE
SOILEDLINENHAMPER
PLAM CLADDOORS
EQ.
EQ.
EQ.
4"
7' - 0
"
EQ.
EQ.
EQ.
EQ.
EQ.
7A-540
SOILED LINEN DROP
STORAGE
SLOPED TOP, TYP.
PLAM CLAD DOORS
18A-540
OPENING FOR TRASH
STORAGE
PLASTIC LAMINATE CLAD DOOR
SIDE TV DOOR
NEW WALL FOR COMMON AREA SEPARATION
DROP DOWN WOOD CEILING RE: RCP
NEW MILLWORK
SCHEDULED BASE
NEW MILLWORK
LOCKABLE CABINETSFOR GAMING SYSTEMS
MILLWORK END PANEL
3' - 0
"4"
4"
V.I.F19' - 1"
4 - 24" X 2" WITH 2" RADIUSWIREWAY CUTOUT OPENINGSEVENLY SPACED
SCHEDULED BASE
1' - 0
"
NEWCOUNTERTOP
NEW PLAMCLADMILLWORK
NEW DOOR
PYXUS(O.F.O.I) 1' - 10"
2' - 6
"
LOCKABLEPLASTIC LAMINATEDRAWERS
LOCKABLEPLASTICLAMINATESLIDING DOORSWITH ACCURIDE1319,HORIZONTALHARDWARE
3 FORMPANEL WITHBACKLIGHT
6' - 4"
V.I.F
CEI
LING
HEI
GHT
8' - 5
" - T
O CE
ILIN
G
4"2'
- 6 1
/2"
1 1/
2"3'
- 9 1
/2"
3' - 0
"
BLACKBOARDPAINT
3 FORMBACKLIGHTPANEL RE: MEP
DECORATIVEPANEL
11 1
/2"
8"
GLASS BLOCKINGGBL-1RE: INTERIOR FINISHSHEETS
SCHEDULED PAINTEDWALL
SCHEDULED BASE
CORNER UNIT
22A-420 SCHEUDLED CEILING
3 5/8" METAL STUD
SCHEDULED FLOOR FINISH SHEDULED WALL FINISH
5/8" GYPSUM BOARD
12"x12" GLASSBLOCK WALL - GBL-1
SCHEDULED WALLBASE
SHEDULED CEILING
SHEDULED WALL FINISH
1/4" BLACK REVEAL
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
07:2
8 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-420
INTERIORELEVATIONS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/2" = 1'-0"6 NOURISHMENT STATION 1/2" = 1'-0"7 LIBRARY WALL
1/2" = 1'-0"19 PATIENT DESK
1/2" = 1'-0"2 CHART ROOM 1/2" = 1'-0"1 CHART ROOM
1/2" = 1'-0"4 CHART ROOM
1/2" = 1'-0"3 CHART ROOM
1/2" = 1'-0"8 1D MEDICINE ROOM SOUTHWEST ELEVATION
1/2" = 1'-0"12 ADA RESTROOM SOUTH ELEVATION 1/2" = 1'-0"13 ADA RESTROOM WEST ELEVATION
1/2" = 1'-0"10 LINEN CABINET 1/2" = 1'-0"11 LINEN CABINET
1/2" = 1'-0"16 HEARTH WALL TRASH CAN UNIT 1/2" = 1'-0"15 1D SEATING AREA
1/2" = 1'-0"14 LAUNDRY ROOM 1/2" = 1'-0"17 GAME ROOM SOUTH WALL
1/2" = 1'-0"18 GAME ROOM WEST WALL
1/2" = 1'-0"9 1D MEDICINE ROOM NORTHEAST WALL
1/2" = 1'-0"5 NOURISHMENT STATION
1/2" = 1'-0"20 TELEPHONE WALL 1/2" = 1'-0"21 1D GLASS BLOCK WALL
1/2" = 1'-0"22 GLASS BLOCK WALL SECTION
No. Description Date
EXISTING WINDOWS V.I.FFOR COMPUTER DESK
MOUNTING. NOTIFYARCHITECT OF ANYINCONSISTENCIES.
SCHEDULED BASE
AFC INDUSTRIES,I-CENTER WALLMOUNTED WORKSTATION MODEL: IR400-001
4' - 0
"
16A-541
4"
1' - 0
"
NEW WINDOWS WITHPAINTED HM FRAME RE:INTERIOR FINISHSCHEDULE
EMERGENCYPOWEREDREFRIGERATORLOCATION
NEW FIXTURE
NEWCABINETRY TOREPLACEEXISTING
NEWCABINETRY TOREPLACEEXISTING
NEW COUNTER TOPAND CABINETRY TOREPLACE EXISTING
PLASTIC LAMINATECLAD DOORS
STORAGE SHELVES
SLOPED TOP, TYP. POWER COLUMN/STRIP
OWNER PROVIDEREFRIGERATOR
NEW FIXTURE
PLASTIC LAMINATE SINK PANEL
SLOPED TOP, TYP
NEW COUNTER TOP ANDCABINETRY TO REPLACEEXISTING
POWER COLUMN/STRIP
BULLETIN BOARD
OWNER PROVIDEDREFRIGERATOR
5' - 0" TYP.
PATIENT BED
EXISTING PARTITION
5' - 0" TYP.
SCHEDULED BASE
4"
EXISTING COLUMN
EXISTING COLUMN
WALL PANEL
RE: FLOORPLAN FOREXACT HEADWALLLOCATION IN EACH
PATIENT ROOM
16A-540
17A-540
TV LOCATION
TRASH CANUNIT
STORAGESTORAGE
TRASH CANUNIT
3 FORM PANEL:3/8" GAUGE,SUPERMATTEFINISH
16A-540
Sim
DECORATIVEPANEL RP-1
DECORATIVEPANEL RP-1
INFORMATIONBOARD:
DISPLAYS2GOSKU:BCF3036OB
INFORMATIONBOARD:
DISPLAYS2GOSKU:BCF3036OB
1/4" REVEALS
3' - 4" 5' - 2 1/2" 3' - 4"
1' - 3
"6"
3' - 3
1/2
"6"
2' - 2
1/2
"4"
1'-9" 5" 5" 1' - 9"
16' - 2"
TO O
PERA
TION
48" M
AX
ACCESSIBLESOAP DISPENSER
(TA1)
48" M
AX
ACCESSIBLE PAPERTOWEL DISPENSER
(TA4)
TO O
PERA
BLE
MEC
HANI
SM
(TA14)
ACCESSIBLE PAPER TOWELDISPENSER AND TRASH
RECEPTACLE
TOW
EL O
UTLE
T48
" MAX
40" M
AX
TO B
OTT
OM
OF
REFL
ECTI
VESU
RFAC
E
TA2
ACCESSIBLE MIRROR
74" M
IN
34" M
AX
TA1
TA2
ACCESSIBLE LAVATORY
17" -
19"
33" -
36"
TOP OF SEAT
TA3
42" MIN12" MAX
ACCESSIBLE TOILET W/ GRAB BARSTOILET PAPER DISPENSER, ANDSANITARY NAPKIN DISPOSAL
ACCESSIBLE TOILETW/ GRAB BARS ANDTOILET PAPER DISPENSER
CLEAR60" MIN
CLEA
R59
"
CLEAR32" MIN
17" 4" MAXTA3
TA5
ACCESSIBLE TOILETCLEARANCE WITH FLOORMOUNTED WATER CLOSET
SIDE
WAL
L
1' - 5"18" MAX
12" MIN
56" M
IN.
60" MIN. 30" MIN
TA3TA5
TA2TA4
ACCESSIBLE TOILETAND SINK
TO O
PERA
TION
48" M
AX
CLOTHES HOOK
(TA11)
54" MIN.
17"
MIN36"
MIN12"
ALLEXPOSPOSEDPIPING TO BEINSULATED;RE: MEPDRAWINGS
9" M
A X7"
MIN
19" M
AX14
" MIN
LOCKED THERMOSTAT
SWITCH / FIRE PULL STATIONDOOR
COAT HOOKS
OUTLET
FIRE ALARM &STROBE
5'-6"
4'-0"
ACCE
SSIB
LE H
EIGH
T
3'-4"
6"
1'-6"
4' -
0"4'-
0" A
CCES
SIBL
E TH
ERMO
STAT
1'-6"
ALIGN OUTLETLOCATIONWITH ELEMENTABOVE, UNO
6' 8
" ALI
GN
6'-8"
TYP
. - TO
BOT
TOM
OF A
PPLIA
NCE
2' -
11 3
/4"
3'-0"
MAX
.TO
BUB
BLER ADA
FINISHED FACEOF FLOOR
5'-0"
1'-3" 2'-6" 1'-3"DOOR TO ADARESTROOM
ROOMSIGNAGEWHEREINDICATEDON SIGNAGEPLANS
DOOR
3'-4"
9"
TO B
OTTO
M O
F BR
AILL
E4'
- 0" M
IN A
ND 5
' - 0
" MAX
COUNTERTOP WHERESCHED.
BACKSPLASH AS SCHED.
MED
GAS
CO
NNEC
TIO
N
COMMUNICATION OUTLETTYP.
WALL OUTLET TYP.
OTH
ER O
UTLE
T
FIRE
ALA
RM P
ULL
STAT
ION
LIG
HT S
WIT
CH
OUT
LET
ABO
VE C
OUN
TERT
OP
THER
MO
STAT
WAL
L M
OUN
TED
PHO
NE &
JAC
K
CODE
BLU
E
NURS
E CA
LL
FIRE
EXT
ING
UISH
ER
4'-0"
FIRE
EXT
ING
UISH
ERCA
BINE
T
GLOVES
GLO
VE D
ISPE
NSER
SHAR
PS D
ISPE
NSER
TOP
OF
DISP
ENSE
R3'-
2" CEN T
ER4'-
0 1/
8"
BOTT
OM
OF
KEYP
AD2'-
10"
9' - 0
"
3 FORM PANEL:3/8" GAUGE,SUPERMATTE FINISH.BACKLIT WITH LED FIXTURERE: MEP DRAWINGS
TV LOCATION
SLIDING GLASS DOORS
17A-540
Sim
1/4" BLACK REVEAL
STAFF LOCKERS
SCHEDULEDBASE
WALLTALKERSNU-VU-RITEWALL COVERING
1' - 6
"
13' - 0" 3' - 6"
STAFF LOCKERSPROVIDED BYOWNER
SLOPED TOP
REUSED DOOR ANDHARDWARENEW WINDOWS WITH
PAINTED HM FRAME RE:INTERIOR FINISHSCHEDULE
16A-541
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
07:3
8 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-421
INTERIORELEVATIONS &
TYPICAL MOUNTINGHEIGHTS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/2" = 1'-0"1 GROUP ROOM NORTH WALL 1/2" = 1'-0"2 GAME ROOM EXTERIOR
1/2" = 1'-0"3 2B MEDICINE ROOM 1/2" = 1'-0"4 2B LAUNDRY ROOM
1/2" = 1'-0"5 2B WORK LOUNGE 1/2" = 1'-0"6 2B WORK LOUNGE
1/2" = 1'-0"7 2B WORK LOUNGE 3
1/2" = 1'-0"8 HEADWALL ELEVATION 1/2" = 1'-0"9 HEARTH WALL AND TRASH CAN UNIT
1/4" = 1'-0"13 BATHROOM ACCESSIBILITY 1/2" = 1'-0"11 TYPICAL MOUNTING HEIGHTS
1/2" = 1'-0"14 TYPICAL MOUNTING HEIGHTS ABOVE COUNTER
1/2" = 1'-0"12 TV CABINET-1D
1/2" = 1'-0"10 GAME ROOM EAST WALL
1/2" = 1'-0"15 GAME ROOM NORTH WALL 1/2" = 1'-0"16 GROUP ROOM SOUTH WALL
No. Description Date
COUNTERTOPRE: I-140 FOR FINISHSCHEDULE
FINISH TRIM
CONTINUOUSWOOD
FRAMING
PLYWOODBRACING
SCHEDULEDFINISH
RE: ELEVATIONS
BLOCKING
EDGE BOUNDINGWITH
COUNTERTOPFINISHH
CONTINUOUSWOOD
FRAMING
COUNTERTOPRE: I-130/ I-140 FORFINISH SCHEDULE
2'-6"
6" 9"
2' - 6 1/2"1' - 8"
5A-541
6A-541
1' - 0
"
6A-541
FINISHTRIM
CONTINUOUSWOOD
FRAMING
SCHEDULEDFINISH
RE: ELEVATIONS
BLOCKING
EDGEBOUNDING
COUNTERTOP
CONTINUOUSWOOD
FRAMING
11A-541
6"
1'-5"
6"
3'-5"
1' - 0
"2'
- 6"
CONTINUOUSWOODFRAMING
SCHEDULEDFINISHRE: ELEVATIONS
EDGEBOUNDINGCOUNTERTOP
ADJUSTABLESHELVES
LINE OF CABINET BEYOND
3"
4"
SEE
ELEV
ATIO
N3'-
6"
10A-541
1'-7"
6"
COUNTERTOPRE: I-140 FOR FINISHSCHEDULE
5A-541
CONTINUOUS WOODFRAMING
FINISH TRIM
CONTINUOUSWOOD
FRAMING
PLYWOODBRACING
SCHEDULEDFINISH
RE: ELEVATIONS
BLOCKING
EDGE BOUNDINGWITH
COUNTERTOPFINISHH
CONTINUOUSWOOD
FRAMING
BOX DRAWER
BOX DRAWER
FILE DRAWER WITHHANGING HARDWARE
6A-541
TOE SPACE
9A-541
2'-0"
3'-5"
1' - 1"
UPPER COUNTERTOP
NURSING STATIONSUPPORT STRUCTURE
R 0'
- 3 1/
4"
R 0' - 3
1/4"
UPPER COUNTERTOP2' - 0
"
7A-541 BACKSPLASH
COUNTERTOP
SUPPORTBRACKET BEYOND
SEE
ELEV
ATIO
N2'-
6"
LINE OF CABINET BEYOND
EXISTING PARTITION
1 1/2" RBULLNOSE
1 1/
2"
FIXED SHELVES
LINE OF CABINET BEYOND
EXISTINGPARTITION
4"
1'-8"
3"
EQEQ
EQEQ
.SEE
ELEV
ATIO
N4'-
0"
CONTINUOUSBLOCKING
3' - 8
"
3/4" PLYWOODHEADWALL WITH PLAMFINISH (SHOPAPPLIED); PANEL ISFULL-HEIGHT AND ISTO BE SET AGAINSTTHE PARTITION ANDSLID INTO PLACE WITHZ-CLIPS INTERLOCKEDAS SHOWN.
CONTINUOUSTREATED WOODFRENCH CLEATRECEIVING ENDSECURED TOPARTITION
CONTINUOUSVERTICAL METAL Z-CLIP SECURED TOPARTITION, EVERY 1'-0" O.C.HORIZONTALLY,TYPICAL
CONTINUOUSTREATED WOODFRENCH CLEAT WITHCURVED END CAPSECURED TOHEADWALL PANEL;COAT JOINT BETWEENCLEAT HALVES WITHADHESIVE PRIOR TOSLIDING PANEL INTOPLACE
EXISTING CMU WALLV.I.F
TYPI
CAL
1' - 0
" O. C
.
3/4" 3/4"
SET FINAL RECEIVINGZ CLIP AGAINSTCORNER PARTITION
METAL Z-CLIPSECURED TO BACK OFHEADWALL PANELEVERY 1'-0" O.C.HORIZONTALLY;INSTALL 4 ROWSTOTAL VERTICALLY,SPACED EQUALLYOVER THE HEIGHT OFTHE PANEL.
1 1/
2"3
1/2"
3 1/
2"
EXISTING PARTITION
PLAM ACCESSPANEL DOORW/ KEYLOCK
MICROWAVEOF/CI
SCHEDULED FIXTURERE: PLUMBINGDRAWINGS
ACCESSIBLEHANDWASH FAUCETRE: PLUMBINGDRAWINGS.
RECESSED LIGHTFIXTURE RE:ELECTRICAL
SCHEDULED CEILING
FURR DOWN
3 FORM PANEL: 3/8"GAUGE, SUPERMATTEFINISH
7' - 5
1/2
"
1/2" 1/2"
4" BACKSPLASH
SLIDING DOOR
3/4"
ICE MACHINE
EXISTING PARTITION
PLASTIC LAMINATECOUNTER TOP
PLASTIC LAMINATEDRAWERS WITH LOCK
1 1/
2"
2' - 8
"4"
BAS
E
EQ.
EQ.
EQ.
SCHEDULED CEILING
FURR DOWN
3 FORM PANEL: 3/8"GAUGE, SUPERMATTEFINISH
1/2" 1/2"
BEVERAGE COOLER:
SUMMIT 11 CU FTCOMMERCIAL
REFRIGERATOR MODEL:SCR1150
7' - 0
"4"
1' - 1
"
DRY STORAGE SHELF
PLASTIC LAMINATESHELF
SCHEDULED CEILING
FURR DOWN
3 FORM PANEL: 3/8"GAUGE, SUPERMATTEFINISH
1/2" 1/2"
7' - 5
1/2
"
PLASTIC LAMINATECLAD DOOR
MOUNTING RAIL
ADJUSTABLE SHELF
BACK PANEL
LOCKABLE SLIDING DOORS
INFORMATION BOARD
3 FORM PANEL: 3/8"GAUGE, SUPERMATTEFINISH
FURR DOWN
SCHEDULEDCEILING
6' - 9
1/2
"
1' - 7
1/2
"CE
ILIN
GTO
SCHEDULED LIGHTFIXTURE; RE: MEPDRAWINGS
ALL INTERIORSURFACES TO BE CLADWITH WHITE MELAMINE
REMOVABLE HARDWOOD STOPS
FIXED HARDWOOD STOPS
7' - 0
"
4"
BACKPANEL
MOUNTING RAIL
ADJUSTABLE SHELF
PLASTIC LAMINATECLAD DOOR
EQ.
EQ.
SPACE2' -0" CLEAR
1' - 0
"6"
3' - 6
"
7' - 0
"
6"
BACK PANEL
ADJUSTABLESHELVES
PLASTIC LAMINATECLAD DOORS
MOUNTING RAIL
45°
DOOR FRAME
1'-6"
3/4"
3/4"
CONTINUOUS TREATED WOOD FRENCH CLEAT WITHCURVED END CAP SECURED ON HEADWALL PANEL;COAT JOINT BETWEEN CLEAT HALVES WITH ADHESIVEPRIOR TO SLIDING PANEL INTO PLACE
3/4" PLYWOOD WALLPANEL WITH PLAMFINISH (SHOP APPLIED);PANEL IS FULL-HEIGHTAND IS TO BE SETAGAINST THE PARTITIONAND SLID INTO PLACEWITH Z-CLIPSINTERLOCKED ASSHOWN.
CONTINUOUS TREATEDWOOD FRENCH CLEATRECEIVING ENDSECURED TOPARTITION
CONTINUOUS VERTICALMETAL Z-CLIP SECUREDTO PARTITION.
METAL Z-CLIP SECUREDTO BACK OF HEADWALLPANEL EVERY 1'-0" O.C.HORIZONTALLY; INSTALL4 ROWS TOTALVERTICALLY, SPACEDEQUALLY OVER THEHEIGHT OF THE PANEL.
3 FORM PANEL: 3/8"GAUGE, SUPERMATTE
FINISH
CONTINUOUS BLOCKING
CONTINUOUS FRAMING
FIXED DECORATIVEPLAM PANEL
INFORMATION BOARD
WOOD PANELED CEILING
REMOVABLE HARDWOOD STOPS1/2" 1/2"
FIXED HARDWOOD STOP W/ TAMPER-RESISTANT ATTACHMENT
SCHEDULED LIGHT FIXTURE; RE:MEP DRAWINGS
ALL INTERIORSURFACES TO BE CLADWITH WHITE MELAMINE
6' - 9
1/2
"
7"
ADJUSTABLE SHELF
CONTINUOUS SLOTS
1/4" X 1/4" BACK REVEAL
CONTINUOUS FRAMING
TWO CONTINUOUS SLOTS1"X16" @ 4 OC
1/4" TEMPERED GLAZING
CONTINUOUS BLOCKING
TWO CONTINUOUS SLOTS1"X16" @ 4" OC,COVERED WITH
STAINLESS STEEL MESH
SLIDING GLASS DOORS
SCHEDULED LIGHT FIXTURE;RE: MEP DRAWINGS
4"2'
- 1 1
/2"
4' - 3
1/2
"8"
V.I.F
TO C
EILI
NG
OFCI TV + MOUNTINGBRACKET
PROVIDE JUNCTION BOXFOR POWER AND DATA
BEHIND TV; RUN CONDUITSTO ABOVE CEILING FORDATA PULL BY OWNER.
3/4" PLYWOOD
3"3" CUTOUT FOR WIRING
3" CUTOUT FOR WIRING 3"
3" CUTOUT FOR WIRING
3"3"
CONDUIT
BACK PANEL
PLASTIC LAMINATE CLAD DOORS
MOUNTING RAIL
ADJUSTABLE SHELVES
SLIM JIM 23 GALLONTRASH CONTAINER
OPEN TRASH DISPOSAL
3/4" PLYWOODHEADWALL WITH PLAMFINISH (SHOPAPPLIED); PANEL ISFULL-HEIGHT AND ISTO BE SET AGAINSTTHE PARTITION ANDSLID INTO PLACE WITHZ-CLIPS INTERLOCKEDAS SHOWN.
CONTINUOUS TREATEDWOOD FRENCH CLEATRECEIVING ENDSECURED TOPARTITION
CONTINUOUSVERTICAL METAL Z-CLIP SECURED TOPARTITION, EVERY 1'-0" O.C.HORIZONTALLY,TYPICAL
CONTINUOUS TREATEDWOOD FRENCH CLEATWITH CURVED END CAPSECURED ONHEADWALL PANEL;COAT JOINT BETWEENCLEAT HALVES WITHADHESIVE PRIOR TOSLIDING PANEL INTOPLACE
EXISTING CMU WALLV.I.F
NO FRENCH CLEATON THIS END
METAL Z-CLIP SECUREDTO BACK OF HEADWALLPANEL EVERY 1'-0" O.C.HORIZONTALLY;INSTALL 4 ROWS TOTALVERTICALLY, SPACEDEQUALLY OVER THEHEIGHT OF THE PANEL.
3/4" 3/4"
1 1/
2"3
1/2"
3 1/
2"TY
PICA
L1'
- 0" O
.C.
3 1/
2"
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
07:5
2 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-540
MILLWORK SECTIONS& DETAILS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1" = 1'-0"1 NURSE STATION SECTION 1" = 1'-0"2 NURSE SECTION
1" = 1'-0"4 NURSE SECTION 1" = 1'-0"3 NURSE STATION SECTION
1" = 1'-0"5 COUNTERTOP CORNER PLAN DETAIL 1" = 1'-0"6 COUNTER TOP PLAN DETAIL
1/2" = 1'-0"20 PATIENT DESK 1/2" = 1'-0"19 PATIENT DESK
1 1/2" = 1'-0"12 TYPICAL HEADWALL 1" = 1'-0"10 NOURISHMENT STATION
1" = 1'-0"11 NOURISHMENT STATION 1" = 1'-0"9 NOURISHMENT STATION 3
1" = 1'-0"15 LIBRARY WALL
1" = 1'-0"8 LINEN CABINET 1" = 1'-0"7 LINEN CABINET
3" = 1'-0"14 WALL PANEL
NOTE: USE ON EXISTING CMU WALL FOREACH LIGHT SWITCH IN PATIENT ROOM,
ADJUST WIDTH WHEREVER NEEDED
1" = 1'-0"16 HEARTH WALL SECTION 1" = 1'-0"17 HEARTH WALL SECTION
1" = 1'-0"18 TRASH CAN UNIT
1 1/2" = 1'-0"13 HEADWALL DETAIL
No. Description Date
BOX DRAWER
BOX DRAWER
BOX DRAWER
2' - 6
"
BOX DRAWER
ADJUSTABLESHELVES
MOUNTING RAIL
BACKSPLASH
PLASTICLAMINATE TOPON 3/4"PLYWOOD
BACKSPLASH
PLASTIC LAMINATE TOP ON3/4" PLYWOOD
CONTINUOUSWOOD LEDGER(BACK & ENDS)
LAVATORY RE: PLUMBING
PLACE DRAIN TOWARDSBACK OF SINK
PLASTIC LAMINATECLAD REMOVABLEPANEL WITH NOEXPOSED FASTNERSINTERMEDIATE SUPPORTPANEL AT 36" O.C. MAX,30" O.C. MIN
1' - 1
1/2
"2"
6 1/
2"
2' - 6
"
PLASTIC LAMINATECLAD DOOR/DRAWERS
ADJUSTABLE SHELF
BACK PANEL
BACK SPLASH
PLASTIC LAMINATETOP ON 3/4"PLYWOOD
ADJUSTABLE SHELVES
MOUNTING RAIL
ADJUSTABLESHELVES
MOUNTING RAIL
BACKSPLASH
PLASTICLAMINATE TOPON 3/4"PLYWOOD
2' - 6
"1'
- 6"
3' - 0
"
PLASTIC LAMINATECLAD DOORS
4"2'
- 5"
4' - 3
"
7' - 0
"
ADJUSTABLESHELVES
MOUNTING RAIL
PLASTICLAMINATECLAD DOORS
BACK PANEL
3/4"3/4"
1 1/2"
1 1/2"3/4"
1 1/2"
3/4"
LINE OFCOUNTERTOPABOVE
FACE OF CABINET
LINE OFCOUNTERTOPABOVE
FACE OF CABINET BELOW
DRAWER/DOOR FRONT
KNEE SPACE
END PANEL BELOW
1 1/2"RADIUS TYP.
1 1/2"RADIUS TYP.
DOUBLEEND PANEL@ OPENSPACE
4 1/8"
3 1/4"
1/8"
SCHEDULED FINISH
FACE OF CABINETCABINET DOOR
1 1/2"3/4"
PANELEND
OPEN KNEESPACEDOUBLE
COUNTERTOP
REFER TO FINISHSCHEDULE FORLOCATIONS OFCOUNTERTOPS.
2 1/2"
MIN.
2 1/2"MIN.
FACE OFCABINET
FINISHCLAD CORNER FILLER
CABINET END PANEL
DRAWER/DOOR PULL
FACE OFCABINET
3/4"
3/4"3/4"
1 1/2"
VARIES
FACE OFCABINET
SELF EDGECOUNTERTOP
FINISH
DRAWER/
RE: SPECSDOOR PULL
3/4"
3/4"3/4"
1 1/2"
VARIES1/2" THICK SOLID SURFACEMATERIAL ON 3/4" SUBSTRATE
1/2" THICK SOLID SURFACEMATERIAL BUILT UP TO FORMBULLNOSE EDGE
FINISH
FACE OF
DRAWER/ DOOR PULLRE: SPECS
CABINET
REFER TO THE FINISH SCHEDULE FOR LOCATIONS OF SOLID SURFACECOUNTERTOP - COORDINATE WITH OWNER
8 COUNTERTOP CORNERPLAN3" = 1'-0"
10 TOE KICKSECTION3" = 1'-0"
12 FINISHED END PANELSECTION @ KNEE SPACE3" = 1'-0"
13 INSIDE CORNERPLAN3" = 1'-0"
05 PLASTIC LAMINATECOUNTERTOP EDGE SECTION3" = 1'-0"
7 SOLID SURFACECOUNTERTOP EDGE SECTION3" = 1'-0"
4 1/8"
1/8"
SCHEDULED FINISH
FACE OF CABINETCABINET DOOR
6 SHALLOW TOE KICKSECTION3" = 1'-0"
3/4" 1/8"
PANEL
REFER TO FINISHSCHEDULE FORLOCATIONS OFCOUNTERTOPS.
9 FINISHED END COUNTERTOPSECTION @ KNEE SPACE3" = 1'-0"
SCHED FINISH
FRY REGLEDREVIL 1/4"x1/4"
BLACK
1 1/
2"
PANEL
11 REVIL @ FACE OF PANELSECTION @ NURSE STATION3" = 1'-0"
SCHED FINISH
FRY REGLEDREVIL 1/4"x1/4"
BLACK
SCHED FINISH
PANEL
SCHED FINISH
PLYWOOD BRACING
1' - 7
1/2
"CE
ILIN
GTO
PLASTIC LAMINATECLAD DOOR
MOUNTING RAIL
ADJUSTABLE SHELF
BACK PANEL
LOCKABLE SLIDING DOORS
1 5/8" METAL STUDS, 25GA. 1' 4" O.C. MAX
3 FORM PANEL: 3/8"GAUGE, SUPERMATTEFINISH
FURR DOWN
SCHEDULEDCEILING
SCHEDULED LIGHTFIXTURE; RE: MEPDRAWINGS
ALL INTERIORSURFACES TO BE CLADWITH WHITE MELAMINE
REMOVABLE HARDWOOD STOPS
FIXED HARDWOOD STOPS
5/8" DRYWALL WITHBLACKBOARD PAINTAPPLIED
CONDUIT FOR PHONEBOX/DATA
4' - 0
"
2' - 0"
2' - 6
"
FOLDOUT DESK
AFC INDUSTRIES I-CENTERWALL MOUNTED WORKSTATION MODEL: IR400-001RE: MANUFACTURERDRAWINGS
EXISTING CMU WALL
4"
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
08:0
2 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-541
MILLWORK SECTIONS& DETAILS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1" = 1'-0"1 UPPER CABINET WITH DRAWERS TYP. 1" = 1'-0"2 UPPER CABINET WITH SINK TYP.
1" = 1'-0"3 UPPER CABINET WITH BASE CABINET TYP. 1" = 1'-0"4 UPPER CABINET WITH COUNTER TYP.
1" = 1'-0"14 CHART ROOM STORAGE CABINET 1" = 1'-0"15 LIBRARY WALL
1/2" = 1'-0"16 FOLDOUT DESK SECTION
No. Description Date
DOOR SCHEDULE "GENERAL NOTES"1. REFER TO A-804 FOR DOOR GLAZING SCHEDULE.
2. REFER TO A-804 FOR DOOR HEAD JAMB AND SILL DETAILS.
3. REFER TO SPECIFICATIONS FOR DESCRIPTIONS OF THE HARDWARE SET AND COORDINATE WITH OWNER.
4. FILL FRAMES (HEAD AND JAMB) OF DOORS OVER 5'-0" WIDE WITH GROUT.
5. PROVIDE A PAIR OF 2X4 STUDS AT THE SIDE OF AND HEAD OF ALL DOORS (U.N.O).
DOOR SCHEDULE LEGEND+ - REFER TO MANUFACTURER.
WD - SOLID CORE WOOD WITH STAINED FINISH.
PL - SOLID CORE WOOD WITH PLASTIC LAMINATE FINISH.
HM - STEEL.
ST - SMOKE TIGHT.
PW - PACKAGE WIDTH.
PH - PACKAGE HEIGHT.
AL1 - ANODIZED ALUMINIUM.
AL2 - BRONZED ALUMINIUM.
PT - PAINTED.
DOOR SCHEDULE REMARKS1. PROVIDE WITH MAGNETIC HOLD OPEN.
2. VIEW WINDOWS IN LARGER LEAF ONLY.
3. REFER TO A-804 FOR ELEVATION OF DOOR WITH A SIDELIGHT.
4. AUTOMATIC CARD SWIPE DOOR.
5. DOOR SWINGS 180 DEGREES.
6. DOOR SWINGS BOTH WAYS.
GLASS TYPESG-3: 1/4 INCH THICK GLAZING QUALITY, CLEAR, TEMPERED FLOAT GLASS.
PARTITION TYPE
5.
6.
7.
9.
REFER TO FLOOR PLAN SERIES A-20X FOR LOCATION OF WALL TYPES. ALL WALLSARE TYPE "A41" UNLESS NOTED OTHERWISE.
REFER TO A-22X SERIES FOR FINAL FINISHES ON PARTITIONS. PARTITION TYPES INCHARTS REFER TO BASE WALL ONLY.
ALL GYPSUM BOARD SHALL BE TYPE "X", UNLESS NOTED OTHERWISE.
PROVIDE ONE LAYER OF 5/8" MOISTURE RESISTANT GYPSUM BOARD AT WALLSBEHIND SINKS AND LAVATORIES WITHOUT TILE. MOISTURE RESISTANT GYPSUMBOARD SHALL BE INSTALLED WITHIN 2' OF ALL URINALS AND WATER CLOSETS, TOA HEIGHT OF 4' AFF.
PROVIDE WATER RESISTANT GYPSUM TILE BACKER BOARD BEHIND ALL TILE AND/OR WALL PANELS AT TUBS AND SHOWERS.
PROVIDE FIRE TREATED WOOD BLOCKING, SHEET METAL OR STEEL BACKING INPARTITIONS TO SUPPORT WALL MOUNTED ITEMS AND EQUIPMENT, ETC.
"LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF THE PARTITIONDETAIL DOES NOT INDICATE THE EXACT CONSTRUCTION CONDITION
SPACING OF THE METAL STUDS HAS NOT BEEN INDICATED ON THE WALL TYPES.STUD SPACING IS TO BE DETERMINED BY THE HEIGHT OF THE WALL AS SHOWN INTHE TABLE BELOW. EACH STUD GOING TO STRUCTURE AND EXCEEDINGALLOWABLE HEIGHTS SHALL BE BRACED 45 DEGREES DIAGONALLY 12" ABOVECEILING WITH EQUAL. SIZE 25 GA. METAL STUDS. THIS TABLE IS TO BE USEDFOR THE INTERIOR WALLS ONLY, AND DOES NOT APPLY TO EXTERIOR STUDS.
ISOLATE NON-LOAD BEARING FRAMING FROM STRUCTURAL ELEMENTS TO PREVENTTHE TRANSFER OF LOAD TO PARTITION FRAMING. STOP STUDS 1/2" BELOW METALRUNNER (TOP TRACK) TO ALLOW FOR VERTICAL EXPANSION. SET TOP TRACK 1"BELOW DEFLECTION TRACK. DO NOT ATTACH STUDS TO TOP TRACK. DO NOTATTACH GYPSUM BOARD TO TOP TRACK. THIS MAY ALSO BE ACHIEVED, AT THECONTRACTOR OPTION, BY UTILIZING THE PROPRIETARY SYSTEM DESCRIBED IN THESPECIFICATIONS. RE:
PROVIDE DOUBLE STUDS AT ALL JAMBS OF OPENINGS OR, PROVIDE STEELCHANNEL WHERE NOTED ELSEWHERE IN THE SET.
ACOUSTICAL
PARTITION TYPE GENERAL NOTES
XX
FACING ONSIDES OF 25
GA. STUDS
STUDSPACING
ON CENTER
STUDDEPTH 2 1/2"
MAX. HEIGHT
STUDDEPTH 3 5/8"
MAX. HEIGHT
STUDDEPTH 6"
MAX. HEIGHT1 LAYER 5/8" GYP.BOARD-1 SIDE ONLY1 LAYER 5/8" GYP.BOARD-EACH SIDE
1624
1624
11'-0"9'-9"
14'-6"12'-9"
14'-6"12'-9"
16'-0"13'-6"
16'-0"13'-6"20'-0"15'-0"
16'-9"13'-6"
1624
2 LAYER 5/8" GYP.BOARD-EACH SIDE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
12'-6"10'-9"
1.
2.
8.
4.
3.
ALL ACOUSTICALLY CLASSED PARTITIONS SHALL BE CONSTRUCTED IN STRICTACCORDANCE TO THE REFERENCED TEST.
STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.SEAL ALL PERIMETER GAPS, AIR TIGHT, AT THE FLOORS, HEAD, ADJACENTCONSTRUCTION AND AROUND ANY PENETRATING ELEMENTS WITH INTERIORGRADE ACOUSTICAL SEALANT.
ALL BATTS AND BLANKETS IN RATED WALLS MUST BEAR THE REQUIRED U.L.CLASSIFICATION MARKING AS TO FIRE-RESISTANCE. ALSO REFER TO CODECOMPLIANCE DETAILS IN A-010 SERIES.
AT ACOUSTICALLY RATED PARTITIONS, DO NOT FILL THE STUD CAVITY(DEPTH) FULLY WITH SOUND BATTS. THE WIDTH OF THE SOUND BATTSSHOULD BE SLIGHTLY SMALLER THAN CAVITY TO AVOID BATTS COMPRESSION.HOWEVER, THE ENTIRE LENGTH AND HEIGHT OF THE WALL SHOULD HAVECONTINUOUS AND UNINTERRUPTED SOUND ATTENUATION BATTS.
REFER TO DETAILS 9,10, 11 AND 12 ON SHEET A-8102 FOR PARTITIONTYPES WITH A DESIGNATED STC RATING.
SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT ACOUSTICALLYCLASSED PARTITIONS IN ACCORDANCE TO DETAIL 12/ A-8102.
SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONSACCORDING TO 9/A-8102 UNLESS THE PARTITION IS ALSO FIRE RATEDWHERE THE CODE COMPLIANCE DETAILS ON THE A-010 SERIES SHOULD BEREFERENCED.
OUTLETS ON OPPOSITE SIDES OF ACOUSTICALLY CLASSED PARTITIONS .
(AS SHOWN ON PLANS IN A-20XX SERIES.)
APPLIED FINISHES SEEFINISH SCHEDULE / PLANS
GB - 1 LAYER EACH SIDE
METAL STUDS
ACOUSTIC INSULATIONWHERE SCHEDULED
BASIC PARTITION THICKNESS
NOTES:* SEE DETAILS FOR BRACING OFPARTITION TYPES A_3 & A_4
STUDS TOSTRUCTUREABOVE (SEEDETAILS)
1 HR. RATED WITH GBTO STRUCTURE ABOVENON RATED WITH GBTO STRUCTURE ABOVENON RATED WITH GBTO 6" ABOVE CEILING
NON RATED WITH STUDS & GB TOFINISHED CEILING (08/A-100.B1)*NON RATED PARTIAL HEIGHT PARTITIONWITH GB TO X'-0" AFF
STUD SIZE
GB THICKNESS
BASIC PARTITION THICKNESS
ACOUSTICAL INSULATION
ACOUSTICAL RATING (STC)
ACOUSTICAL TEST NUMBER
FIRE TEST NUMBER (WHERE APPLICABLE)
LOCAL CODE REQUIREMENT
REMARKS
A11
A12
A13
A14
2 1/2"
5/8"
3 3/4"
2 1/2"
5/8"
3 3/4"
NO YES
40 49
SIM. USG860808
N/A
- -
- -
-
-
-
-
-
-
-
-
-
-
-
-
SIM. SA870717
SIM. USG860808
SIM. USG870717
SIM. USG860808
SIM. SA870717
SIM. USG860808
SIM. USG870717
NO YES YES YESNO NO
40 49 40 49 40 49
3 5/8" 3 5/8" 4" 4" 6" 6"
5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
4 7/8" 4 7/8" 5 1/4" 5 1/4" 7 1/4" 7 1/4"
N/A UL DESU465
UL DESU465
UL DESU465
UL DESU465
UL DESU465
UL DESU465
A21
A22
A23
A24
A30
A31
A32
A33
A33A34
A40
A41
A42
A43
A44
A50
A53
A52
A51
A54
A60
A61
A62
A63
A64
A70
A71
A72
A73
A74
A80
A81
A82
A83
A84
STUDS TOSTRUCTURE ABOVE(SEEDETAILS)
2 HR. RATED WITH GBTO STRUCTURE ABOVENON RATED WITH GBTO STRUCTURE ABOVENON RATED WITH GB TO6" ABOVE CEILING
NON RATE WITH STUDS & GB TOFINISHED CEILING (SEE DETAILS) *NON RATED PARTIAL HT. PARTITIONWITH GB TO X'-0" AFF (SEE DETAIL) *
STUD SIZE
GB THICKNESS
BASIC PARTITION THICKNESS
ACOUSTICAL INSULATION
ACOUSTICAL RATING (STC)
ACOUSTICAL TEST NUMBER
FIRE TEST NUMBER (WHERE APPLICABLE)
REMARKS
APPLIED FINISHED SEEFINISH SCHEDULE / PLANS
METAL STUDS
ACOUSTIC INSULATIONWHERE SCHEDULED
BASIC PARTITION THICKNESS
NOTES:* SEE DETAILS FOR BRACINGOF PARTITION TYPES D_3 & D_4
NO NO NO NOYES YES YES YES
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2 1/2" 2 1/2" 3 5/8" 3 5/8" 4" 4" 6" 6"
5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
3 1/8" 3 1/8" 4 1/4" 4 1/4" 4 5/8" 4 5/8" 6 5/8" 6 5/8"
D11
D12
D13
D14
D21
D22
D23
D24
D31
D32
D33
D34
D41
D42
D43
D44
D81D51
D52
D53
D54
D61
D62
D63
D64
D71
D72
D73
D74
D82
D83
D84
STUDS EXCEEDING 12' FOOT HEIGHTREQ. MIN-HT BRACING TOSTRUCTURE
GB - 1 LAYER SYMBOL SIDE
SCHED. WIDTH
SCHE
D. H
EIGH
T
0' - 8
"
0' - 8"0' - 8"0' - 6" 0' - 6"
3' - 8
"
N2
WIDTH
SCHED. FRAME
SCHE
D. F
RAM
E HE
IGHT
SCHE
D. D
OOR
HEIG
HT
WIDTH
SCHED. DOOR
SD
SCHE
D. F
RAM
E HE
IGHT
SCHED. FRAME WIDTH
SCHE
D. D
OOR
HEIG
HT
SCHED.DOOR WIDTH
DEDOUBLE EGRESS FRAME
WIDTH
SCHED.
0' - 8
"
SCHE
D. H
EIGH
T
0' - 6"0' - 8"
3'-8"
N1
1' - 0
"
W1
3' - 2"
7'-2"
WIDTH
SCHED.
SCHE
D. H
EIGH
T
SCHED. WIDTH
F1F2
WINDOW TYPESFRAME TYPES
DOOR TYPES
WIDTH
SCHED.
SCHE
D. H
EIGH
T
F3
3'-8"
2' - 0" 6"
2' - 1
0"
SCHEDULED PARTITION
GYPSUM BOARDAS SPEC'D.
BATT INSULATIONAS SCHED.
BOUBLE STUDSAT WINDOWOPENING
METAL STUDWALL AS SCHED.
SEALANT BOTHSIDES
HM FRAME
APPLIED METAL STOP
RE: WINDOWSCHEDULE FOR
GLAZING
2"5/8
"
JAMB ANCHORS - 3PER JAMB
1/2"
GYPSUM BOARDAS SPEC'D.
BATT INSULATIONAS SCHED.
BUILT-UP STUDHEADER AS REQ'D.
METAL STUD WALLAS SCHED.
SEALANT BOTH SIDES
SCHEDULED PARTITION
EQ.
HM FRAME
METAL TRACK
APPLIED METAL STOP
RE: WINDOWSCHEDULE FORGLAZING
1/2"2"
5/8"
1/2" MIN.
H.M. FRAME5 7/8"
1/2" MIN.
V.I.F
CONTINUOUSSEALANT BOTHSIDES (TYP.)
PAINTED HOLLOWMETAL FRAME
JAMB ANCHORS
2"SC
HED.
DOO
R HE
IGHT
SCHEDULED DOOR
EXISTING PARTITION
1/2" MIN.
HM FRAME
1/2" MIN.
V.I.F.
CONTINUOUSSEALANT BOTHSIDES (TYP.)
PAINTED HOLLOWMETAL FRAME
EXISTING PARTITION
2"SC
HED.
DOO
R HE
IGHT
SCHEDULED DOOR
FRAMEAND DOOR ASSCHEDULED
LINE OF DRYWALLPARTITION BEYOND
FLOOR FINISHAS SCHEDULED
SHEDULED FLOOR.
FRAMESCHED.
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
08:1
3 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
A-610
DOOR, WINDOWSCHEDULE AND
DETAILS
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
WINDOW SCHEDULE
TYPEMARK
R.O. FrameFinish Sill
GlazingHead HeightWidth Height Thickness Type
W2 3' - 2" 6' 2" PT-8 1' - 0" 1/4" G3 7' - 2"W2 3' - 2" 6' 2" PT-8 1' - 0" 1/4" G3 7' - 2"W2 3' - 2" 6' 2" PT-8 1' - 0" 1/4" G3 7' - 2"W2 3' - 2" 6' 2" PT-8 1' - 0" 1/4" G3 7' - 2"
3" = 1'-0"4 INTERIOR WINDOW HM SILL DETAIL 3" = 1'-0"5 INTERIOR WINDOW HM HEAD DETAIL
3" = 1'-0"6 JAMB DETAIL 3" = 1'-0"7 HEAD DETAIL
3" = 1'-0"8 HM DOORSILL DETAIL
UNIT 1D DOOR SCHEDULE
DOORTAG
ScheduledHardware
Set
OPENING SIZEDoorType
DOORGlassType
FrameType
FRAMEFire
Rating CommentsWidth Height Finish Material Material Finish Jamb Head Sill1-D11 2 3' - 0" 7' - 0" F3 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D12 1 3' - 0" 7' - 0" F3 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D13 1 3' - 0" 7' - 0" F3 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D14 1 3' - 0" 7' - 0" F3 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO BUBBLE TO BE ADDED BY OWNER1-D15 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D18 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D19 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D20 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D21 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D23 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D24 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D25 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D26 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D28 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D29 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D30 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D31 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D32 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D33 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D34 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D35 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO
1-D35A 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO1-D36 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO SLIDING GLASS WINDOW TO
REPLACE EXIST1-D37 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO
Grand total: 24
UNIT 2B DOOR SCHEDULE
WTWT
ScheduledHardware
Set
OPENING SIZEDoorType
DOORGlassType
FrameType
FRAMEFire
Rating CommentsWidth Height Finish Material Material Finish Jamb Head Sill2-B44 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B45 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B46 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B47 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B48 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B49 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B50 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B51 2 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B52 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B53 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO OWNER FURNISHED, CONTRACTOR
INSTALLED G3 GLAZING IF NECESSARY2-B54 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B55 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B56 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B57 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B60 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B61 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B62 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B63 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B65 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B66 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B67 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B68 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B70 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B71 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B72 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B73 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B74 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B75 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B76 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B77 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B78 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B80 1 3' - 6" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO2-B81 1 3' - 0" 7' - 0" F1 MATCH EXIST HW NO SD HM PT-8 6/A-610 7/A-610 8/A-610 NO
Grand total: 33
NOTE: ALL DOORS TO BE REFURBISHED AND REUSED UNLESSNOTED OTHERWISE. REFER TO PLAN FOR SWING CHANGES WITHNEW DOOR PLACEMENT. NOTIFY ARCHITECT OF ANY DOORS THATMAY NEED TO BE REPLACED.
No. Description Date
REF.
1-E28
Room
1-D00OFFICE1-D01
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14 GROUP ROOM
1-D15
PATIENT ROOM1-D18
PATIENT ROOM1-D19
PATIENT ROOM1-D20
PATIENT ROOM1-D21
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D28
PATIENT ROOM1-D29
PATIENT ROOM1-D30
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36
CHART ROOM1-D37
1-D39
1-D40
Room
1-D42
1-D43
1-D44
1-D46 1-D47
1-D481-D49
1-D50
1-H06
STAIR1-0S0F
RESTROOM1-D35A
RESTROOM1-D32
COMMON AREA1-H07
LVT-1RB-1
PT-1,3ACT
LVT-1RB-1PT-1GWB
LVT-1RB-1
PT-1,3ACT
LVT-2RB-1PT-2GWB
LVT-2RB-1PT-2GWB
LVT-2RB-1PT-1GWB
LVT-1RB-1PT-1GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-1,2RB-1
PT-1,3*
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
RE: I-210WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
PT-3
PT-3
PT-3PT
-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
FINISH SECTIONS - CEILINGS
FINISH SECTIONS - FLOORING
GENERAL FINISH PLAN NOTES
FINISH PLAN LEGEND
SS-1PL-2
REFER TO INTERIOR FINISH LEGEND SHEET I-200 & I-201 FORKEYNOTES AND COMPLETE LIST OF SCHEDULED FINISHES.
KEYNOTE
CEILING FINISHWALL FINISHWALL BASE FINISHFLOOR FINISH
ROOM FINISH TAG
MILLWORK IN AND OUT SIDE/ VERTICAL SURFACE FINISHCOUNTERTOPS, BENCHES / HORIZONTAL SURFACE FINISH
MILLWORK FINISH TAG
REFER TO INTERIOR ELEVATIONS, AS REFERENCED ONARCHITECTURAL PLANS, FOR ADDITIONAL INFORMATION.
ALL INSTALLATION PROCEDURES SHALL BE IN ACCORDANCE WITHEACH MANUFACTURER'S INSTRUCTIONS.
SUBMIT SAMPLES OF ALL SCHEDULED FINISHES FOR APPROVAL,PRIOR TO ORDERING.
AFTER PROJECT COMPLETION, ALL FINISHES AND SURFACES TOBE THOROUGHLY CLEANED.
*DENOTES MULTIPLE FINISHES. REFER TO ENLARGEDPLANS AND/OR ELEVATIONS FOR INFORMATION.
ACTVWCRB
VCT
CG
1.
2.
3.
4.
5.
PAWLIMG PRO-TEK MODEL CG-10 CORNER GUARD
P1 DENOTES ACCENT WALL PAINT
1
4" RUBBER WALL BASE TO BE STANDARD - FLEXCO - COVE"CAPPUCCINO" # 65
FINISH SECTIONS - WALL BASERB-1
6. ALL MILLWORK FINISH PL-3 INSIDE AND OUTSIDE; UNLESS NOTED.
7. ALL INTERIOR FINISHES FOR WALLS, CEILINGS AND FLOORS COMPLY WITHIBS 2006 SECTION 803 & 804:* FLOORING - VINYL FLOORING - FLOORING RADISNT PANEL TEST (ASTM-E-648) PASSES CLASS 1* WALL BASE - CLASS C* WALL PROTECTION - CLASS 1*ACOUSTICAL CEILING - CLASS AALL PAINT FINISHES PT-1 ON WALLS; UNLESS NOTED.8.
PTP-1 : AMERICAN OLEAN 6" X 24" PLANKS - "TERRENO DRIFTWOOD"# TE15 (RESTROOM MAIN FLOOR)
LVT-1 : KARNDEAN 36" X 6" - "OPUS: PALLEO" # WP312 (MAIN)*
LVT-2 : KARNDEAN 36" X 4" - "OPUS: GOLDEN TEAK" # WP513 (ACCENT)*
SHERWIN WILLIAMS - EGGSHELL "EAGLET BEIGE" # 7573
SHERWIN WILLIAMS - EGGSHELL "DORMER BROWN" # 7521PT-2
PT-1
SHERWIN WILLIAMS - EGGSHELL "RAIN" # 6219PT-3
RP-1 (DECORATIVE PANELS - HEARTH WALL) LUMICOR RESIN "GRASSES ANDREEDS: SCATTER" (HEARTH WALL)
SH SILL HEIGHT
(WALL: ACCENT STRIP) AMERICAN OLEAN - GLASS & NATURALSTONE 3 X RANDOM MOSAIC "COLOR APPEAL: PACIFIC COASTBLEND" #C136 (RESTROOMS)
PTP-5
(WALL MAIN) AMERICAN OLEAN 10"X14" "DURANGO CREAM" # SC85BRICK JOINT, VERTICALLY INSTALLED (RESTROOMS)
PTP-4
PTP-2 : AMERICAN OLEAN 2X2 MOSAIC - "SALCEDO: DURANGOCREAM" # SC85 (INSIDE SHOWER)
GYPSUM BOARD CEILING (ALL PATIENTS ROOMS & RESTROOMS)
24X24 ACOUSTICAL CEILING SAND MICRO TILES (ALL PUBLICS AREASAND OFFICES AND STORAGE)
ACT
GWB
HEARTH CEILING -LINEAR WOOD CEILING - LINWOOD - LINWOOD I"BAMBOO CARMELIZED HORIZONTAL"
CL-3
FINISHES - DOOR & WINDOW FRAMESPT-8 PAINT- INTERIOR DOOR FRAMES - SHERWIN WILLIAMS # 7521
"DORMER BROWN"
FINISH SECTIONS - WALLS
PL-2 WILSONART #6257 (419) SATIN BRUSHED NATURAL ALUMINUM (TOEKICK ON NURSE STATION AND LIBRARY WALL ONLY)
FINISH SECTIONS - TOE KICK
ALL CEILING TO BE 24x24 ACT; UNLESS NOTED.9.
GROUTG-1 (BATHROOM WALL) LATICRETE "ANTIQUE WHITE" #23G-2 (BATHROOM FLOOR) LATICRETE "BUTTERCREAM" #81
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE( MILLWORKTYP. )
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE (HEARTHWALL )
WB WALL BASE: COVE TYPE TO MATCH FLOOR TILE TYPE AND SIZE( ALL RESTROOMS)
GBL-1 (PARTIAL WALL SHOWERS) GLASS BLOCKS 12x12x4 PITTSBURGHCORNING - "DECORA LX PATTERN"
MILLWORKP-1 3 FORM PANEL: 3/8" GAUGE, SUPERMATTE FINISH
SHERWIN WILLIAMS - EGGSHELL "CHRYSANTHEMUM" # 6347PT-4
*PATTERNS INDICATE DIRECTIONAL FLOOR PATTERN
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
09:4
3 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
I-201
1D INTERIOR FINISHPLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 1D INTERIOR FLOOR PATTERN PLAN
No. Description Date
REF
.PATIENT ROOM2-B80
2-OSOA 2-EL6
OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
GROUP ROOM2-B51
WORK LOUNGE2-B52
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
COMMON AREA2-H1
SECLUSION ROOM2-B54
OFFICE2-B56
2-B74RESTROOM
PATIENT ROOM2-B73
2-OSOOD
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
RESTROOM2-B67
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
2-H10
RESTROOM2-B77
RESTROOM2-B81
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWT
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-2RB-1
PT-1,3GWB
LVT-1RB-1
PT-1,2ACT
LVT-1RB-1
PT-1,2ACT
LVT-1RB-1
PT-1,2ACT
LVT-1RB-1
PT-1,2ACT
LVT-1RB-1
PT-1,2ACT
LVT-1RB-1
PT-1,2ACT
LVT-2RB-1
PT-1,3ACT
LVT-1RB-1PT-1GWB
LVT-1RB-1PT-1GWB
LVT-1,2RB-1
PT-1,3*
LVT-2RB-1PT-2GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
*WBPT-1GWB
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
LVT-2RB-1PT-1GWB
LVT-1RB-1
PT-1,3ACT
PT-3
LVT-2RB-1PT-4ACT
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
FINISH SECTIONS - CEILINGS
FINISH SECTIONS - FLOORING
GENERAL FINISH PLAN NOTES
FINISH PLAN LEGEND
SS-1PL-2
REFER TO INTERIOR FINISH LEGEND SHEET I-200 & I-201 FORKEYNOTES AND COMPLETE LIST OF SCHEDULED FINISHES.
KEYNOTE
CEILING FINISHWALL FINISHWALL BASE FINISHFLOOR FINISH
ROOM FINISH TAG
MILLWORK IN AND OUT SIDE/ VERTICAL SURFACE FINISHCOUNTERTOPS, BENCHES / HORIZONTAL SURFACE FINISH
MILLWORK FINISH TAG
REFER TO INTERIOR ELEVATIONS, AS REFERENCED ONARCHITECTURAL PLANS, FOR ADDITIONAL INFORMATION.
ALL INSTALLATION PROCEDURES SHALL BE IN ACCORDANCE WITHEACH MANUFACTURER'S INSTRUCTIONS.
SUBMIT SAMPLES OF ALL SCHEDULED FINISHES FOR APPROVAL,PRIOR TO ORDERING.
AFTER PROJECT COMPLETION, ALL FINISHES AND SURFACES TOBE THOROUGHLY CLEANED.
*DENOTES MULTIPLE FINISHES. REFER TO ENLARGEDPLANS AND/OR ELEVATIONS FOR INFORMATION.
ACTVWCRB
VCT
CG
1.
2.
3.
4.
5.
PAWLIMG PRO-TEK MODEL CG-10 CORNER GUARD
P1 DENOTES ACCENT WALL PAINT
1
4" RUBBER WALL BASE TO BE STANDARD - FLEXCO - COVE"CAPPUCCINO" # 65
FINISH SECTIONS - WALL BASERB-1
6. ALL MILLWORK FINISH PL-3 INSIDE AND OUTSIDE; UNLESS NOTED.
7. ALL INTERIOR FINISHES FOR WALLS, CEILINGS AND FLOORS COMPLY WITHIBS 2006 SECTION 803 & 804:* FLOORING - VINYL FLOORING - FLOORING RADISNT PANEL TEST (ASTM-E-648) PASSES CLASS 1* WALL BASE - CLASS C* WALL PROTECTION - CLASS 1*ACOUSTICAL CEILING - CLASS AALL PAINT FINISHES PT-1 ON WALLS; UNLESS NOTED.8.
PTP-1 : AMERICAN OLEAN 6" X 24" PLANKS - "TERRENO DRIFTWOOD"# TE15 (RESTROOM MAIN FLOOR)
LVT-1 : KARNDEAN 36" X 6" - "OPUS: PALLEO" # WP312 (MAIN)*
LVT-2 : KARNDEAN 36" X 4" - "OPUS: GOLDEN TEAK" # WP513 (ACCENT)*
SHERWIN WILLIAMS - EGGSHELL "EAGLET BEIGE" # 7573
SHERWIN WILLIAMS - EGGSHELL "DORMER BROWN" # 7521PT-2
PT-1
SHERWIN WILLIAMS - EGGSHELL "RAIN" # 6219PT-3
RP-1 (DECORATIVE PANELS - HEARTH WALL) LUMICOR RESIN "GRASSES ANDREEDS: SCATTER" (HEARTH WALL)
SH SILL HEIGHT
(WALL: ACCENT STRIP) AMERICAN OLEAN - GLASS & NATURALSTONE 3 X RANDOM MOSAIC "COLOR APPEAL: PACIFIC COASTBLEND" #C136 (RESTROOMS)
PTP-5
(WALL MAIN) AMERICAN OLEAN 10"X14" "DURANGO CREAM" # SC85BRICK JOINT, VERTICALLY INSTALLED (RESTROOMS)
PTP-4
PTP-2 : AMERICAN OLEAN 2X2 MOSAIC - "SALCEDO: DURANGOCREAM" # SC85 (INSIDE SHOWER)
GYPSUM BOARD CEILING (ALL PATIENTS ROOMS & RESTROOMS)
24X24 ACOUSTICAL CEILING SAND MICRO TILES (ALL PUBLICS AREASAND OFFICES AND STORAGE)
ACT
GWB
HEARTH CEILING -LINEAR WOOD CEILING - LINWOOD - LINWOOD I"BAMBOO CARMELIZED HORIZONTAL"
CL-3
FINISHES - DOOR & WINDOW FRAMESPT-8 PAINT- INTERIOR DOOR FRAMES - SHERWIN WILLIAMS # 7521
"DORMER BROWN"
FINISH SECTIONS - WALLS
PL-2 WILSONART #6257 (419) SATIN BRUSHED NATURAL ALUMINUM (TOEKICK ON NURSE STATION AND LIBRARY WALL ONLY)
FINISH SECTIONS - TOE KICK
ALL CEILING TO BE 24x24 ACT; UNLESS NOTED.9.
GROUTG-1 (BATHROOM WALL) LATICRETE "ANTIQUE WHITE" #23G-2 (BATHROOM FLOOR) LATICRETE "BUTTERCREAM" #81
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE( MILLWORKTYP. )
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE (HEARTHWALL )
WB WALL BASE: COVE TYPE TO MATCH FLOOR TILE TYPE AND SIZE( ALL RESTROOMS)
GBL-1 (PARTIAL WALL SHOWERS) GLASS BLOCKS 12x12x4 PITTSBURGHCORNING - "DECORA LX PATTERN"
MILLWORKP-1 3 FORM PANEL: 3/8" GAUGE, SUPERMATTE FINISH
SHERWIN WILLIAMS - EGGSHELL "CHRYSANTHEMUM" # 6347PT-4
*PATTERNS INDICATE DIRECTIONAL FLOOR PATTERN
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
09:5
8 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
I-202
2B INTERIOR FINISHPLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION 1/8" = 1'-0"1 2B INTERIOR FINISH PLAN
No. Description Date
1-D00OFFICE1-D01
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14
GROUP ROOM1-D15
PATIENT ROOM1-D18
PATIENT ROOM1-D19
PATIENT ROOM1-D20
PATIENT ROOM1-D21
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D28
PATIENT ROOM1-D29
PATIENT ROOM1-D30
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36
CHART ROOM1-D37
1-D40
1-D42
1-D44
1-D46
1-D48
1-H06
STAIR1-0S0F
RESTROOM1-D35A
RESTROOM1-D32
COMMON AREA1-H07
LVT-2
LVT-2
LVT-2
LVT-2
LVT-2
LVT-2 LVT-2 LVT-2 LVT-2 LVT-2 LVT-2
LVT-2
LVT-2 LVT-2
LVT-1
LVT-2
LVT-2 LVT-2 LVT-1
LVT-1
LVT-1
PTP-2 PTP-2
PTP-2 PTP-2
PTP-1
PTP-1 PTP-1
PTP-1
PTP-1
FINISH SECTIONS - CEILINGS
FINISH SECTIONS - FLOORING
GENERAL FINISH PLAN NOTES
FINISH PLAN LEGEND
SS-1PL-2
REFER TO INTERIOR FINISH LEGEND SHEET I-200 & I-201 FORKEYNOTES AND COMPLETE LIST OF SCHEDULED FINISHES.
KEYNOTE
CEILING FINISHWALL FINISHWALL BASE FINISHFLOOR FINISH
ROOM FINISH TAG
MILLWORK IN AND OUT SIDE/ VERTICAL SURFACE FINISHCOUNTERTOPS, BENCHES / HORIZONTAL SURFACE FINISH
MILLWORK FINISH TAG
REFER TO INTERIOR ELEVATIONS, AS REFERENCED ONARCHITECTURAL PLANS, FOR ADDITIONAL INFORMATION.
ALL INSTALLATION PROCEDURES SHALL BE IN ACCORDANCE WITHEACH MANUFACTURER'S INSTRUCTIONS.
SUBMIT SAMPLES OF ALL SCHEDULED FINISHES FOR APPROVAL,PRIOR TO ORDERING.
AFTER PROJECT COMPLETION, ALL FINISHES AND SURFACES TOBE THOROUGHLY CLEANED.
*DENOTES MULTIPLE FINISHES. REFER TO ENLARGEDPLANS AND/OR ELEVATIONS FOR INFORMATION.
ACTVWCRB
VCT
CG
1.
2.
3.
4.
5.
PAWLIMG PRO-TEK MODEL CG-10 CORNER GUARD
P1 DENOTES ACCENT WALL PAINT
1
4" RUBBER WALL BASE TO BE STANDARD - FLEXCO - COVE"CAPPUCCINO" # 65
FINISH SECTIONS - WALL BASERB-1
6. ALL MILLWORK FINISH PL-3 INSIDE AND OUTSIDE; UNLESS NOTED.
7. ALL INTERIOR FINISHES FOR WALLS, CEILINGS AND FLOORS COMPLY WITHIBS 2006 SECTION 803 & 804:* FLOORING - VINYL FLOORING - FLOORING RADISNT PANEL TEST (ASTM-E-648) PASSES CLASS 1* WALL BASE - CLASS C* WALL PROTECTION - CLASS 1*ACOUSTICAL CEILING - CLASS AALL PAINT FINISHES PT-1 ON WALLS; UNLESS NOTED.8.
PTP-1 : AMERICAN OLEAN 6" X 24" PLANKS - "TERRENO DRIFTWOOD"# TE15 (RESTROOM MAIN FLOOR)
LVT-1 : KARNDEAN 36" X 6" - "OPUS: PALLEO" # WP312 (MAIN)*
LVT-2 : KARNDEAN 36" X 4" - "OPUS: GOLDEN TEAK" # WP513 (ACCENT)*
SHERWIN WILLIAMS - EGGSHELL "EAGLET BEIGE" # 7573
SHERWIN WILLIAMS - EGGSHELL "DORMER BROWN" # 7521PT-2
PT-1
SHERWIN WILLIAMS - EGGSHELL "RAIN" # 6219PT-3
RP-1 (DECORATIVE PANELS - HEARTH WALL) LUMICOR RESIN "GRASSES ANDREEDS: SCATTER" (HEARTH WALL)
SH SILL HEIGHT
(WALL: ACCENT STRIP) AMERICAN OLEAN - GLASS & NATURALSTONE 3 X RANDOM MOSAIC "COLOR APPEAL: PACIFIC COASTBLEND" #C136 (RESTROOMS)
PTP-5
(WALL MAIN) AMERICAN OLEAN 10"X14" "DURANGO CREAM" # SC85BRICK JOINT, VERTICALLY INSTALLED (RESTROOMS)
PTP-4
PTP-2 : AMERICAN OLEAN 2X2 MOSAIC - "SALCEDO: DURANGOCREAM" # SC85 (INSIDE SHOWER)
GYPSUM BOARD CEILING (ALL PATIENTS ROOMS & RESTROOMS)
24X24 ACOUSTICAL CEILING SAND MICRO TILES (ALL PUBLICS AREASAND OFFICES AND STORAGE)
ACT
GWB
HEARTH CEILING -LINEAR WOOD CEILING - LINWOOD - LINWOOD I"BAMBOO CARMELIZED HORIZONTAL"
CL-3
FINISHES - DOOR & WINDOW FRAMESPT-8 PAINT- INTERIOR DOOR FRAMES - SHERWIN WILLIAMS # 7521
"DORMER BROWN"
FINISH SECTIONS - WALLS
PL-2 WILSONART #6257 (419) SATIN BRUSHED NATURAL ALUMINUM (TOEKICK ON NURSE STATION AND LIBRARY WALL ONLY)
FINISH SECTIONS - TOE KICK
ALL CEILING TO BE 24x24 ACT; UNLESS NOTED.9.
GROUTG-1 (BATHROOM WALL) LATICRETE "ANTIQUE WHITE" #23G-2 (BATHROOM FLOOR) LATICRETE "BUTTERCREAM" #81
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE( MILLWORKTYP. )
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE (HEARTHWALL )
WB WALL BASE: COVE TYPE TO MATCH FLOOR TILE TYPE AND SIZE( ALL RESTROOMS)
GBL-1 (PARTIAL WALL SHOWERS) GLASS BLOCKS 12x12x4 PITTSBURGHCORNING - "DECORA LX PATTERN"
MILLWORKP-1 3 FORM PANEL: 3/8" GAUGE, SUPERMATTE FINISH
SHERWIN WILLIAMS - EGGSHELL "CHRYSANTHEMUM" # 6347PT-4
*PATTERNS INDICATE DIRECTIONAL FLOOR PATTERN
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
10:2
4 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
I-210
1D INTERIOR FLOORPATTERN PLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 1D INTERIOR FINISH PLAN
No. Description Date
REF
.
FINISH SECTIONS - CEILINGS
FINISH SECTIONS - FLOORING
GENERAL FINISH PLAN NOTES
FINISH PLAN LEGEND
SS-1PL-2
REFER TO INTERIOR FINISH LEGEND SHEET I-200 & I-201 FORKEYNOTES AND COMPLETE LIST OF SCHEDULED FINISHES.
KEYNOTE
CEILING FINISHWALL FINISHWALL BASE FINISHFLOOR FINISH
ROOM FINISH TAG
MILLWORK IN AND OUT SIDE/ VERTICAL SURFACE FINISHCOUNTERTOPS, BENCHES / HORIZONTAL SURFACE FINISH
MILLWORK FINISH TAG
REFER TO INTERIOR ELEVATIONS, AS REFERENCED ONARCHITECTURAL PLANS, FOR ADDITIONAL INFORMATION.
ALL INSTALLATION PROCEDURES SHALL BE IN ACCORDANCE WITHEACH MANUFACTURER'S INSTRUCTIONS.
SUBMIT SAMPLES OF ALL SCHEDULED FINISHES FOR APPROVAL,PRIOR TO ORDERING.
AFTER PROJECT COMPLETION, ALL FINISHES AND SURFACES TOBE THOROUGHLY CLEANED.
*DENOTES MULTIPLE FINISHES. REFER TO ENLARGEDPLANS AND/OR ELEVATIONS FOR INFORMATION.
ACTVWCRB
VCT
CG
1.
2.
3.
4.
5.
PAWLIMG PRO-TEK MODEL CG-10 CORNER GUARD
P1 DENOTES ACCENT WALL PAINT
1
4" RUBBER WALL BASE TO BE STANDARD - FLEXCO - COVE"CAPPUCCINO" # 65
FINISH SECTIONS - WALL BASERB-1
6. ALL MILLWORK FINISH PL-3 INSIDE AND OUTSIDE; UNLESS NOTED.
7. ALL INTERIOR FINISHES FOR WALLS, CEILINGS AND FLOORS COMPLY WITHIBS 2006 SECTION 803 & 804:* FLOORING - VINYL FLOORING - FLOORING RADISNT PANEL TEST (ASTM-E-648) PASSES CLASS 1* WALL BASE - CLASS C* WALL PROTECTION - CLASS 1*ACOUSTICAL CEILING - CLASS AALL PAINT FINISHES PT-1 ON WALLS; UNLESS NOTED.8.
PTP-1 : AMERICAN OLEAN 6" X 24" PLANKS - "TERRENO DRIFTWOOD"# TE15 (RESTROOM MAIN FLOOR)
LVT-1 : KARNDEAN 36" X 6" - "OPUS: PALLEO" # WP312 (MAIN)*
LVT-2 : KARNDEAN 36" X 4" - "OPUS: GOLDEN TEAK" # WP513 (ACCENT)*
SHERWIN WILLIAMS - EGGSHELL "EAGLET BEIGE" # 7573
SHERWIN WILLIAMS - EGGSHELL "DORMER BROWN" # 7521PT-2
PT-1
SHERWIN WILLIAMS - EGGSHELL "RAIN" # 6219PT-3
RP-1 (DECORATIVE PANELS - HEARTH WALL) LUMICOR RESIN "GRASSES ANDREEDS: SCATTER" (HEARTH WALL)
SH SILL HEIGHT
(WALL: ACCENT STRIP) AMERICAN OLEAN - GLASS & NATURALSTONE 3 X RANDOM MOSAIC "COLOR APPEAL: PACIFIC COASTBLEND" #C136 (RESTROOMS)
PTP-5
(WALL MAIN) AMERICAN OLEAN 10"X14" "DURANGO CREAM" # SC85BRICK JOINT, VERTICALLY INSTALLED (RESTROOMS)
PTP-4
PTP-2 : AMERICAN OLEAN 2X2 MOSAIC - "SALCEDO: DURANGOCREAM" # SC85 (INSIDE SHOWER)
GYPSUM BOARD CEILING (ALL PATIENTS ROOMS & RESTROOMS)
24X24 ACOUSTICAL CEILING SAND MICRO TILES (ALL PUBLICS AREASAND OFFICES AND STORAGE)
ACT
GWB
HEARTH CEILING -LINEAR WOOD CEILING - LINWOOD - LINWOOD I"BAMBOO CARMELIZED HORIZONTAL"
CL-3
FINISHES - DOOR & WINDOW FRAMESPT-8 PAINT- INTERIOR DOOR FRAMES - SHERWIN WILLIAMS # 7521
"DORMER BROWN"
FINISH SECTIONS - WALLS
PL-2 WILSONART #6257 (419) SATIN BRUSHED NATURAL ALUMINUM (TOEKICK ON NURSE STATION AND LIBRARY WALL ONLY)
FINISH SECTIONS - TOE KICK
ALL CEILING TO BE 24x24 ACT; UNLESS NOTED.9.
GROUTG-1 (BATHROOM WALL) LATICRETE "ANTIQUE WHITE" #23G-2 (BATHROOM FLOOR) LATICRETE "BUTTERCREAM" #81
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE( MILLWORKTYP. )
PL-3 WILSONART #7951K-18 "ASIAN SUN" P-LAMINATE (HEARTHWALL )
WB WALL BASE: COVE TYPE TO MATCH FLOOR TILE TYPE AND SIZE( ALL RESTROOMS)
GBL-1 (PARTIAL WALL SHOWERS) GLASS BLOCKS 12x12x4 PITTSBURGHCORNING - "DECORA LX PATTERN"
MILLWORKP-1 3 FORM PANEL: 3/8" GAUGE, SUPERMATTE FINISH
SHERWIN WILLIAMS - EGGSHELL "CHRYSANTHEMUM" # 6347PT-4
*PATTERNS INDICATE DIRECTIONAL FLOOR PATTERN
PATIENT ROOM2-B80
2-OSOA 2-EL6OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
GROUP ROOM2-B51
WORK LOUNGE2-B52
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
COMMON AREA2-H1
SECLUSION ROOM2-B54
OFFICE2-B56
2-B74RESTROOM
PATIENT ROOM2-B73
2-OSOOD
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
RESTROOM2-B67
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
RESTROOM2-B77
RESTROOM2-B81
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
LVT-2
LVT-1
LVT-1
LVT-1
LVT-1 LVT-1
LVT-1
LVT-1
LVT-2
LVT-2
LVT-2
LVT-2
LVT-2
LVT-2
LVT-2 LVT-2
LVT-2 LVT-2
LVT-2 LVT-2
LVT-2
LVT-1
LVT-2
LVT-2 LVT-2
LVT-1 LVT-1
LVT-2
LVT-1
PTP-2 PTP-2
PTP-2 PTP-2
PTP-1 PTP-1
PTP-1 PTP-1
PTP-1
PTP-1
PTP-2
PTP-1
PTP-2
TRUENORTH
PLANNORTHKEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
Copy
right
© 20
12 P
BK
www.pbk.com
MEP:
Shah Smith& ASSOCIATES, INC
2825 Willcrest, Suite #350Houston, Texas 77046
713-780-7563 P713-780-9209
Texas Registered Engineering Firm: F-2113
In Association with:
Healthcare
9/16
/201
5 4:
10:4
0 PM
C:\U
sers
\ vga
rcia
\Doc
u men
ts\1
4265
_AR
CH
_vga
rcia
.rvt
HARR
I S C
OUNT
YPS
YCHI
ATRI
C CE
NTER
UNI
T1 D
AND
2B R
ENOV
ATI O
N
I-211
2B INTERIOR FLOORPATTERN PLAN
JM
VG
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1 2B INTERIOR FLOOR PATTERN PLAN
No. Description Date
OFF
AUTOHAND
OFFON
ST
F
MFAP
FSD
J
LCP
LC
D
RL
K
4
3
T
M
LC
OS
OS
LUMINAIRE WALL MOUNTED
ELECTRICAL ONE-LINE AND CONTROL SYMBOLS
TRANSFER SWITCH
CONNECTION POINT
PANELBOARD
VARIABLE FREQUENCY DRIVE
MAGNETIC MOTOR STARTER
DIGITAL MULTI-METER
DISCONNECT SWITCH, FUSIBLE
FUSE
CURRENT TRANSFORMER
POWER TRANSFORMER
STRIP LUMINAIRE
GROUND
MANUAL FIRE ALARM PULL STATION
LIGHTING CONTACTOR
MANUAL DIMMER SWITCH
THREE WAY SNAP SWITCH
FOUR WAY SNAP SWITCH
KEY OPERATED SNAP SWITCH
SINGLE POLE SNAP SWITCH
LUMINAIRE
LUMINAIRE - WALL WASH
2'X2' LUMINAIRE
2'X4' LUMINAIRE
LUMINAIRE
QUADRUPLEX RECEPTACLE MOUNTED FLUSH IN FLOOR BOX
DISCONNECT SWITCH, NON FUSIBLE, 30A, 3P UON
DISCONNECT SWITCH, FUSIBLE, 30A, 3P UON
COMBINATION SWITCH STARTER, NEMA SIZE '1' UON
CONDUIT CAPPED
CONDUIT TURNED DOWN
CONDUIT TURNED UP
SINGLE RECEPTACLE, SUBSCRIPT IS DEFINED AS FOLLOWS:a = NEMA 6-30Rb = 480V, 3-PHASE PLUS GND, 50A, HUBBELL #CS8165C, OASc = NEMA 15-30R
ELECTRICAL PLAN SYMBOLS
POWER/DISTRIBUTION PANELBOARD
LIGHTNING PROTECTION AIR TERMINAL
GROUND ROD
EQUIPMENT ENCLOSURE
OVERLOAD
SPACE HEATER
1'X4' LUMINAIRE
1'X4' LUMINAIRE - EMERGENCY POWER
2'X2' LUMINAIRE - EMERGENCY POWER
2'X4' LUMINAIRE - EMERGENCY POWER
LUMINAIRE - EMERGENCY POWER
TWIN HEAD WALL MOUNTED EMERGENCYLUMINAIRE - BATTERY OPERATED
EXIT SIGN WITH DIRECTIONAL ARROWSAS INDICATED SHADING INDICATESNUMBER OF FACES & CONFIGURATION
RAISE/LOWER SWITCH
OCCUPANCY SENSOR CEILING MOUNTED-360° COVERAGE - DUAL TECHNOLOGY
MANUAL TIMER SWITCH - O - 2 HOUR
DM
OPEN DELTA CONNECTED
SURGE PROTECTIVE DEVICE
DELTA CONNECTED
WYE CONNECTEDCONTROL PANEL
FIRE ALARM SYMBOLS
LIGHTNING PROTECTION CONDUCTORLP
GROUNDING CONDUCTORG
EMERGENCY PANELBOARD-FLUSH MOUNTED
HOMERUN - TWO PHASE, ZERO, ONEOR TWO NEUTRAL AS SCHEDULED BY TICKMARKS, ONE GROUNDING CONDUCTOR
HOMERUN - THREE PHASE, ZERO, ONEOR THREE NEUTRAL AS SCHEDULED BY TICKMARKS, ONE GROUNDING CONDUCTOR
MOTOR SINGLE PHASE - HP AS NOTED
X
POLE MOUNTED LUMINAIRE
TRACK LIGHTING SYSTEM
LOCAL ROOM CONTROL FOR DIMMINGAND/OR LIGHTING CONTROL SYSTEM.
SINGLE RECEPTACLE MOUNTED FLUSH IN FLOOR BOX
SINGLE RECEPTACLE, SPECIAL PURPOSE MOUNTED
DUPLEX RECEPTACLE MOUNTED FLUSH IN FLOOR BOX
Y SUBSCRIPT DENOTES
WP WEATHERPROOFGFCI GROUND FAULT CIRCUIT INTERRUPTERIG ISOLATED GROUNDE EMERGENCYCM MOUNTED FLUSH IN CEILING OR
SURFACE OF STRUCTURE ABOVE
OCCUPANCY SENSOR WALL MOUNTED - DUAL TECHNOLOGY
JUNCTION OR PULLBOX, WALL MOUNTED
JUNCTION OR PULLBOX, FLUSH MOUNTED IN FLOOROR FLOORBOX AS NOTED ON PLANS
JUNCTION OR PULLBOX, CEILING MOUNTED
LIGHTING AND APPLIANCE BRANCH CIRCUITPANELBOARD - SURFACE MOUNTED
POWER/DISTRIBUTION PANELBOARD
GROUNDING SYSTEM TEST WELL
DIGITAL MULTI-METER
CONDUIT EXPOSED
CONDUIT EMBEDDED
MOTOR THREE PHASE - HP AS NOTED
CONTACTOR COIL
SELECTOR SWITCH
FIRE/SMOKE DAMPER
TWO SPEED MOTOR - HP AS NOTED
HOMERUN - ONE PHASE - ONE NEUTRAL,ONE GROUNDING CONDUCTOR
CONTINUATION
EMERGENCY PANELBOARD-SURFACE MOUNTED
CIRCUIT BREAKER WITHSHUNT TRIP COIL
SURGE SUPRESSOR, METAL OXIDEVARISTOR (MOV) MAXIMUMCONTINUOUS OPERATING VOLTAGE(MCOV) AS NOTED
METER
1/4
CONTROL RELAY
CONTACT, NORMALLY OPEN
CONTACT, NORMALLY CLOSED
INDICATING LAMP, COLORAS NOTED, R RED, GGREEN, A AMBER, W WHITE
SELECTOR SWITCH, ON-OFF
NORMALLY OPEN PUSHBUTTON,
GROUNDED WYE
EXIT SIGN WALL MOUNTED
DIRECTION ARROW FOR EXIT SIGN
DIRECTION ARROW FOR EXIT SIGN
LIGHTING CONTROL PANEL
LIGHTING AND APPLIANCE BRANCH CIRCUITPANELBOARD - FLUSH MOUNTED
GENERATOR THREE PHASE SIZE AS NOTED
LUMINAIRE WALL MOUNTED - EMERGENCY POWER
STRIP LUMINAIRE - EMERGENCY POWER
QUADRUPLEX RECEPTACLE
DUPLEX RECEPTACLE
M1/6
KEY INTERLOCKK
M
CP
SPD
STARTER, NEMA SIZE '1' UON
ABBREVIATIONS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
LUMINAIRE FLUSH MOUNTEDX
LUMINAIRE FLUSH MOUNTED - EMERGENCY POWERX
NORMALLY CLOSED PUSHBUTTON,MAINTAINED CONTACT
MOMENTARY CONTACT
VIBRATION SWITCH
FLUSH IN FLOOR BOX - SURFACE MOUNTED
- FLUSH MOUNTED
MOLDED OR INSULATEDCASE CIRCUIT BREAKER
DISCONNECT SWITCH, NON-FUSIBLE
CURRENTTRANSFORMER, ZEROSEQUENCE
VOLTAGE OR POWER TRANSFORMER
PROTECTIVE RELAY FUNCTION,ANSI DESIGNATION AS NOTED
SELECTOR SWITCH,HAND-OFF-AUTOMATIC
PUSHBUTTON,MAINTAINED CONTACT
GENERATOR THREEPHASE SIZE AS NOTED
MOTOR, THREE-PHASE,HP AS NOTED
TWO SPEED MOTOR- HP AS NOTED
MOTOR, SINGLE PHASE,HP AS NOTED
SUBSCRIPT DENOTESX LETTER DENOTES TYPE
SINGLE POLE HP RATED MOTORDISCONNECT SWITCHRAISE/LOWER SWITCH
MAIN FIRE DETECTION & ALARM PANEL
20
SINGLE POLE SNAP SWITCH WITH WEATHERPROOFCOVER
a
Y
Y
Y
Y
Y
Y
A,AMP AMPERESAC ALTERNATING CURRENT, AIR
COMPRESSORACC AIR COOLED CHILLERAD AIR DRYERAF AMPERE FRAMEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAIC AMPERES INTERRUPTING CAPACITYAL ALUMINUMARCH ARCHITECT, ARCHITECTURALAT AMPERE TRIPATS AUTOMATIC TRANSFER SWITCHAUX AUXILIARYAV AUDIO VISUALAWG AMERICAN WIRE GAUGE
B BOILERBF BALLAST FACTORBAS BUILDING AUTOMATION SYSTEMBCP BOILER CONTROL PANELBFP BOILER FEEDWATER PUMPBKR BREAKERBLDG BUILDINGBFDF BOILER FORCED DRAFT FANBIDF BOILER INDUCED DRAFT FAN
CL CENTERLINEC CONDUITCAFSS CLEAN AGENT FIRE SUPPRESSION SYSTEMCAOP CHILLER AUXILIARY OIL PUMPCATV CABLE TELEVISION SYSTEMCB CIRCUIT BREAKERCCP CHILLER CONTROL PANELCCTV CLOSED CIRCUIT TELEVISION SYSTEMCDP CONDENSATE PUMPCH CHILLERCHP CHILLED WATER PUMPCKT CIRCUITCLG CEILINGCMH COMMUNICATIONS MANHOLECOAX COAXIAL CABLECONT CONTINUATIONCOORD COORDINATION/COORDINATECP CONTROL PANELCPT CONTROL POWER TRANSFORMERCSU COLLEGE STATION UTILITIESCT CURRENT TRANSFORMER, COOLING TOWERCTF COOLING TOWER FANCTR CONTROLLERCU COPPER, CONDENSING UNITCV CONSTANT VOLUME TERMINAL UNITCWP CONDENSER WATER PUMP
DA DEAERATORDATACOM DATA AND/OR COMMUNICATIONDB DUCT BANKDC DIRECT CURRENTDCS DISTRIBUTED CONTROL SYSTEMDDC DIRECT DIGITAL CONTROLDEMO DEMOLITIONDIP DEIONIZED WATER PUMPDIV DIVISIONDPDT DOUBLE POLE, DOUBLE THROWDPST DOUBLE POLE, SINGLE THROWDWG DRAWINGDWP DOMESTIC WATER PUMP
E, EM EMERGENCYEA EACHEC EMPTY CONDUITEDF ELECTRIC DRINKING FOUNTAINEF EXHAUST FANEG EQUIPMENT GROUNDEGP ELECTRONIC GRADE PANELELS EMERGENCY LIFE SAFETYEMS ENERGY MANAGEMENT SYSTEMEMT ELECTRIC METALLIC TUBINGEPR ETHYLENE-PROPYLENE RUBBEREIWH ELECTRIC INSTANT WATER HEATEREXIST EXISTING
FA FIRE DETECTION AND ALARM SYSTEMFCU FAN COIL UNITFCV FAN-CONSTANT VOLUME TERMINAL
UNITFLA FULL LOAD AMPSFO FIBER OPTIC(S)FP FIRE PUMPFSD FIRE SMOKE DAMPERFUT FUTUREFVNR FULL VOLTAGE NON-REVERSINGFVV FAN-VARIABLE VOLUME TERMINAL
UNIT
GAOP GEAR AUXILIARY OIL PUMPGEN GENERATORGFCI GROUND FAULT CIRCUIT
INTERRUPTERGFEP GROUND FAULT EQUIPMENT
PROTECTIONG, GND GROUNDGRAP GENERATOR REMOTE
ANNUNCIATOR PANELGWH GAS-FIRED WATER HEATER
H HOTHID HIGH INTENSITY DISCHARGEHMT HARMONIC MITIGATING TRANSFORMERHOA HAND OFF AUTOMATICHP HORSEPOWERHPS HIGH PRESSURE SODIUMHRG HIGH RESISTANCE GROUNDHVAC HEATING, VENTILATING, AND AIR
CONDITIONINGHWC HOT WATER CIRCULATING PUMPHWP HEATING WATER PUMP
I/O INPUT/OUTPUTIG ISOLATED GROUNDIR INFRAREDIRR IRRIGATIONIS INSTANT START
JB JUNCTION BOXJP JOCKEY PUMP
K KILO, THOUSANDKA KILOAMPERESKAIC THOUSAND AMPERES INTERRUPTING
CAPACITYKCMIL THOUSAND CIRCULAR MILSKV KILOVOLTKVA KILOVOLT AMPERESKW KILOWATTKWH KILOWATT-HOUR
LTG LIGHTINGLC LIGHTING CONTACTOR
LCP LIGHTING CONTROL PANELLED LIGHT EMITTING DIODELP LIGHTNING PROTECTIONLR LOCAL-REMOTELRA LOCKED ROTOR AMPERESLS LONG TIME, SHORT TIMELSI LONG TIME, SHORT TIME,
INSTANTANEOUSLSG LONG TIME, SHORT TIME, GROUNDLSIG LONG TIME, SHORT TIME,
INSTANTANEOUS, GROUNDLI LONG TIME, INSTANTANEOUSLIG LONG TIME, INSTANTANEOUS,
GROUND
mA MILLIAMPSMAX MAXIMUMMCB MAIN CIRCUIT BREAKERMCC MOTOR CONTROL CENTERMCP MOTOR CIRCUIT PROTECTORMECH MECHANICALMFAP MAIN FIRE DETECTION & ALARM
PANELMFR MANUFACTURERMH METAL HALIDEMLO MAIN LUGS ONLYMOV METAL OXIDE VARISTORMTD MOUNTEDMV-90, 105 MEDIUM VOLTAGE CABLE 90 C, 105CMVA MEGA VOLT AMPERESMW MEGA WATTS
N, NEU NEUTRALNC NORMALLY CLOSEDNEC NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICAL
MANUFACTURER'SASSOCIATION
NIC NOT IN CONTRACTNO NORMALLY OPEN# NUMBERNTS NOT TO SCALE
OAS OR APPROVED SUBSTITUTIONOCPD OVERCURRENT PROTECTIVE DEVICEOC ON CENTEROFCI OWNER FURNISHED, CONTRACTOR
INSTALLEDOFOI OWNER FURNISHED, CONTRACTOR
INSTALLEDOH OVERHEADOL OVERLOAD
P POLEPA PUBLIC ADDRESSPB PULL BOXPCHP PRIMARY CHILLED WATER PUMPPDU POWER DISTRIBUTION UNITPF POWER FACTORPFCC POWER FACTOR CORRECTION
CAPACITORPH PHASEPIR PASSIVE INFRAREDPLC PROGRAMMABLE LOGIC CONTROLLERPMH POWER MANHOLEPMT PAD MOUNTPNL PANELBOARDPS PROGRAMMED STARTPVC POLYVINYL CHLORIDEPVC-RGS PVC COATED RIGID GALVANIZED
STEEL CONDUIT
RAC RIGID ALUMINUM CONDUITRCPT RECEPTACLERE REFER TO, REGARDING, REFERENCERFAP REMOTE FIRE DETECTION & ALARM
PANELRGS RIGID GALVANIZED STEEL CONDUITRL RAISE-LOWERRMS ROOT MEAN SQUAREROP REVERSE OSMOSIS PUMPRS RAPID STARTRTD RESISTANCE TEMPERATURE
DETECTORRVAT REDUCED-VOLTAGE AUTO
TRANSFORMER
SCADA SUPERVISORY CONTROL & DATAACQUISITION
SCH SCHEDULESCHP SECONDARY CHILLED WATER PUMPSEP SEWAGE EJECTOR PUMPSF SUPPLY FANSHLD SHIELDEDSP SUMP PUMPSPD SURGE PROTECTION DEVICESPDT SINGLE POLE, DOUBLE THROWSPST SINGLE POLE, SINGLE THROWSPF STAIRWELL PRESSURIZATION FANSS STAINLESS STEELSSOL SOLID STATE OVER LOADSTD STANDARDSTP SHIELDED TWISTED PAIRSW SWITCHSWBD SWITCHBOARDSWGR SWITCHGEARSYM SYMMETRICALSYNCH SYNCHRONOUS
TELECOM TELECOMMUNICATIONSTOP TURBINE OIL PUMPTSP TWISTED SHIELDED PAIRTVSS TRANSIENT VOLTAGE SURGE
SUPPRESSORTYP TYPICAL
UG UNDERGROUNDUH UNIT HEATERUL UNDERWRITER'S LABORATORYUON UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLYUTP UNSHIELDED TWISTED PAIR
V VOLTSVA VOLT AMPERESVAC VOLTS ALTERNATING CURRECTVAR VOLT AMPERES REACTIVEVDC VOLTS DIRECT CURRENTVFD VARIABLE FREQUENCY DRIVEVP VACUUM PUMPVT VOLTAGE TRANSFORMERVV VARIABLE VOLUME TERMINAL UNIT
W WIREW/ WITHWG WIRE GUARDWH WATER HEATERWP WEATHERPROOF
XFMR TRANSFORMER
Y WYE
Z IMPEDANCE
FAAP FIRE ALARM ANNUNCIATOR PANEL
WP
RELAY
TRANSFORMER
ENCLOSED CIRCUIT BREAKERTYPE AND SIZE AS NOTED
PUSH BUTTON
KIRK KEY INTERLOCK
BUZZER
BELL
K
R
DM
VS
R
M
VFD
CB
T
S
S
S
S
S
S
S
S
S
S
J
J
EXISTING PANELBOARDSURFACE MOUNTED
EXISTING PANELBOARDFLUSH MOUNTED
KEYED NOTES SYMBOL #
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:10:2
5 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-001
ELECTRICAL LEGENDSYMBOLS AND
ABBREVIATIONS
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
No. Description Date
LUMINAIRE SCHEDULE
TYPE MANUFACTURERAND CATALOG NUMBER
DESCRIPTION
A
VOLTAGE LAMPS MOUNTING MAXWATTS
REMARKS
DAY-BRITE #2DP-GH-232-FA12-277-PAF 2'X4' FLUORESCENT LENSED LAY-IN TROFFERWITH AIR HANDLING FUNCTION, <10% THD, HPF,BF 0.88 MIN.
277
3-32W T84100K85 CRI
LAY-IN96
ONE 2-LAMP AND ONE 1-LAMPPROGRAMMED STARTELECTRONIC BALLASTS, <10%THD
XA
CHLORIDE #CA6-RW-1-CEILING RECESS MOUNTSINGLE FACE EDGE LIT EXIT SIGN WITHRECESSED ALUMINUM HOUSING 120/277
LED WALL ORCEILING 5
UNSWITCHED, NO BATTERY BACKUP
XB
CHLORIDE #CA6-RW-2-CEILING RECESS MOUNTDOUBLE FACE EDGE LIT EXIT SIGN WITHRECESSED ALUMINUM HOUSING 120/277
LED WALL ORCEILING 5
UNSWITCHED, NO BATTERY BACKUP.
A2FINELITE #HPR-A-2X4-DCO-2T8-277-SC-C1-PS-AR 2'X4' FLUORESCENT HIGH PERFORMANCE
RECESSED TROFFER WITH AIR HANDLINGFUNCTION, <10% THD, HPF, BF 0.88 MIN.
277
2-32W T84100K85 CRI
LAY-IN64
ONE 2-LAMP PROGRAMMEDSTART ELECTRONIC BALLAST,<10% THD
C2'X2' FLUORESCENT LENSED LAY-IN TROFFERWITH AIR HANDLING FUNCTION, <10% THD, HPF,BF 0.88 MIN.
277
4-17W T84100K85 CRI
LAY-IN68
TWO 2-LAMP PROGRAMMEDSTART ELECTRONIC BALLASTS,<10% THD
DAY-BRITE #2DP-GH-417-FA12-277-PAF
2'X2' FLUORESCENT HIGH PERFORMANCERECESSED TROFFER WITH AIR HANDLINGFUNCTION, <10% THD, HPF, BF 0.88 MIN.
277
2-17W T84100K85 CRI
LAY-IN34
ONE 2-LAMP PROGRAMMEDSTART ELECTRONIC BALLAST,<10% THD
FINELITE #HPR-A-2X2-DCO-2T8-277-SC-C1-PS-AR
C2
D1'X4' FLUORESCENT LENSED FLANGED TROFFERWITH TAMPER RESISTANT HARDWARE, <10% THD,HPF, BF 0.88 MIN.
277
2-32W T84100K85 CRI
RECESSED64
ONE 2-LAMP PROGRAMMEDSTART ELECTRONIC BALLAST,<10% THD
COOPER #FMR-X-12-232-UNV-80/84-EB81-CPH
F2'X4' FLUORESCENT LENSED FLANGEDTROFFER WITH TAMPER RESISTANT HARDWAREAND ACRYLIC INNER AND TEMPERED GLASSOUTER LENS
277
3-32W T84100K85 CRI
RECESSED96
ONE 2-LAMP AND ONE 1-LAMPPROGRAMMED STARTELECTRONIC BALLAST, <10%THD
COOPER #FSR-SC-D-24-332-80/94-EB82
BCOOPER #FRR-142-UNV-94 COMPACT FLUORESCENT LENSED DOWNLIGHT
WITH VANDAL RESISTANT HARDWARE AND0.187" THICK TEMPERED GLASS LENS
277
1-32W TRT4100K82 CRI
RECESSED35
ONE 1-LAMP PROGRAMMEDSTART ELECTRONIC BALLAST,<10% THD
G6" APERTURE LED DOWNLIGHT WITH MEDIUMDISTRIBUTION, CLEAR APERTURE TRIM COLORAND SEMI-SPECULAR FINISH 277
LED RECESSED25
ONE 0-10V DIMMABLE LEDDRIVER
GOTHAM #EVO-45/14-6AR-MD-MVOLT
H4" APERTURE LED DOWNLIGHT WITH CLEARAPERTURE TRIM COLOR AND SEMI-SPECULARFINISH 277
LED RECESSED30
ONE 0-10V DIMMABLE LEDDRIVER
GOTHAM #ECSR-41/10-4AR-277
JEW POWERCORE LED, ADJUSTABLE ACCENTLIGHT MOUNTED TO CEILING OF BACKLIGHTINGCOMPARTMENT AND SHINING ON BACK WALL OFCOMPARTMENT
277
LED2200K
SURFACE8
ELV COMPATIBLE DIMMABLELED DRIVER
PHILIPS #523-000050-30
KLED UNDER CABINET LIGHT WITH INTEGRALROCKER SWITCH AND JUNCTION BOX FOR QUICKELECTRICAL CONNECTION 120
LED3000K
SURFACE8.6
DIMMABLE LED DRIVERLITHONIA #UCLD18-3000K-WH
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:10:3
1 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-002
LUMINAIRESCHEDULES
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
No. Description Date
REF.
S3
S3
S3
S3
S3
S3
SS
SS
SS
SS
SS S
S
S 3
S S
S3
S3
S3
S3
S S
S
S
S
S
S
S3
S3
S3
S3
S3
S3
S3
S 3
S 3
S 3
S 3
SSSS
SS S
S
S
S3
SS
3
S
S D
1-D00
1-D00
OFFICE1-D01
1-D01
OFFICE1-D02
1-D02
OFFICE1-D03
1-D03
OFFICE1-D04
1-D04
OFFICE1-D05
1-D05
CLASSROOM1-D06
1-D06
COMPUTER ROOM1-D07
1-D07
GAME ROOM1-D11
1-D11
MULTI-PURPOSE
1-D12
1-D12
LAUNDRY ROOM1-D13
1-D13
SECLUSION1-D14
1-D14
GROUP ROOM1-D15
1-D15
PATIENT ROOM1-D18
1-D18
PATIENT ROOM1-D19
1-D19
PATIENT ROOM1-D20
1-D20
PATIENT ROOM1-D21
1-D21
RESTROOM1-D23
1-D23
ADARESTROOM
1-D24
1-D24
ADARESTROOM
1-D25
1-D25
RESTROOM1-D26
1-D26
PATIENT ROOM1-D28
1-D28
PATIENT ROOM1-D29
1-D29
PATIENT ROOM1-D30
1-D30
PATIENT ROOM1-D31
1-D31
PATIENT ROOM1-D33
1-D33
PATIENT ROOM1-D34
1-D34
PATIENT ROOM1-D35
1-D35
MEDICINE ROOM1-D36
1-D36
CHART ROOM1-D37
1-D37
1-D40
1-D40
1-D42
1-D42
1-D44
1-D44
1-D46
1-D46
1-D48
1-D48
1-D50
1-D50
1-H06
1-H06
STAIR1-0S0F
1-0S0F
RESTROOM1-D35A
1-D35A
RESTROOM1-D32
1-D32
COMMON AREA1-H07
1-D92
F F F F F F
B
B
B B
B
B
B
B B B
B
B
B
B
B B
B
B
A2 A2
A2 A2 A2
A2 A2 A2 A2 A2
B
BB
F
B
B B
F
B
B
BF
B
B
B
F
B
BF
F
A2
A2
A2 A2
A2 A2
A2 A2
A2 A2 A2
A2 A2 A2
A2
A2
A2
A2
A2
A2
A2
A2
A2 A2
A2
A
A2
A2
A2
A2
A2 A2
A2 A2
A2
A2
A2 A2
11
11 1
1
1
1
1
1ab
cd
a a
aa
a a a
a
a
a
a
a a
A2
B
B B
B
D D
DD
cG cG
cG
cG
cG
cG
dG
dG
d
G
d
G
dG
BD
2
2
2
1LS
TA
1LS
TB
1HS
T
C1H
ST
C1L
ST
E1H
ST
XFMR T1ST
12
1212
12
12
12
12
3 3
12
12
1HST-13
1HST-9
C1HST-6
E1HHC
12
4
J
J
J
K
K
1LS
TC
1LSTC-5
J
J
J
J JJ J
JJ
J
J
f
ff
f 5
f
f
f
f fff
f
ff
f
6
66
6
2
6
A2
c
A2
c
A2
a
A2
a
A2
12
cG
cG
A2A2
12 12
A2 A2
A2 A2
A2A2A2
A2 A2
A2A2
A2
c
c c c
c
c c
cc
c c c
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:10:3
7 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-101.1D
ELECTRICALLIGHTING PLAN AREA
1D
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1FIRST FLOOR LIGHTING PLAN - AREA D
KEYED NOTES - E-101.1D1 EXISTING THREE-WAY LIGHT SWITCH IN THIS
LOCATION TO BE RE-USED. SWITCH SHOWN TOILLUSTRATE LIGHTING CONTROL ONLY.
2 EXISTING NORMAL POWER LIGHTING CONTROLIN THIS SPACE TO BE REUSED. REMOVECRITICAL BRANCH SWITCH AND PROVIDE NEWDEVICE PLATE THAT BLANKS OFF SECONDSWITCH POSITION IN BOX.
3 PROVIDE UL 924 RELAY, ENTERTAINMENTNETWORKS #EPC-277,OAS, FOR CONTROL OFLS LIGHTING IN GROUP AREAS. CONNECT TOSWITCH LEG AS INDICATED.
4 LIGHTING, CIRCUITING, AND LIGHTINGCONTROL IN THIS AREA IS SHOWN FORINFORMATION ONLY. WORK INSIDE THIS AREAIS BY OTHERS.
5 PROVIDE NEW LUTRON NOVA-T, OAS, 277VAC,ELECTRONIC LOW VOLTAGE DIMMER SWITCHFOR CONTROL OF ACCENT LIGHTING BEHIND3FORM PANELS.
6 CONNECT ACCENT LIGHTING BEHIND 3FORMPANELS TO CIRCUIT SERVING COMMON AREAGENERAL LIGHTING, TYP.
GENERAL NOTES - E-101.1DA. SEE SHEET E-001 FOR ELECTRICAL LEGEND
AND ABBREVIATION. SEE ARCHITECT FORFINAL LUMINAIRE LOCATIONS.
B. ALL EMERGENCY LUMINAIRES AND EXITLIGHTS ARE TO REMAIN UNSWITCHED, UON.
C. LIGHTED EXIT SIGNS ARE SHOWN FORQUANTITIES AND GENERAL LOCATIONS.COORDINATE WITH ARCHITECT FOR EXACTLOCATION OF LIGHTED EXIST SIGNS.
D. SINGLE-FACE EXIT SIGNS ARE TYPE XA, UON.DOUBLE-FACE SIGNS ARE TYPE XB, UON.
E. COORDINATE ELECTRICAL WORK WITHARCHITECT, CIVIL, STRUCTURAL, MECHANICAL,AND PLUMBING SO AS TO AVOIDINTERFERENCE WITH OR COMPROMISE OFOTHER SYSTEMS.
F. SEE ENLARGED ELECTRICAL PLANS FORLOCATION OF LIGHTING BRANCH CIRCUITPANELBOARDS AND LIGHTING CONTACTORS.
G. LIFE SAFETY LIGHTING ON THIS SHEET ISSERVED FROM PANEL E1HST. NUMBERINDICATES CIRCUIT NUMBER.
No. Description Date
RE
F.
S3
S3
S3
S3
S3
S3
SS
SS
SS
SS
SS S
S
S3
S S
S3
S3
S3
S
S
S
S
S
S
S
S 3
S S
SSSS
S 3
S3
S3
S3
S3
S3
S3
S3
S 3
S 3
S 3
S3
S 3
SS
SS
S
S
S D
S
PATIENT ROOM2-B80
1-D38
2-OSOA
1-D51
2-EL6
1-D52
OFFICE2-B44
1-D53
OFFICE2-B45
1-D54
OFFICE2-B47
1-D55
MECHANICALROOM2-B49
1-D56
GROUP ROOM2-B51
1-D57WORK LOUNGE
2-B52
1-D58
OFFICE2-B50
1-D59
OFFICE2-B48
1-D60
OFFICE2-B46
1-D61
PATIENT ROOM2-B78
1-D63
PATIENT ROOM2-B76
1-D64
PATIENT ROOM2-B75
1-D65
COMMON AREA2-H1
1-D66
SECLUSIONROOM2-B54
1-D67
OFFICE2-B56
1-D68
2-B74RESTROOM
1-D69
PATIENT ROOM2-B73
1-D70
2-OSOOD
1-D71
PATIENT ROOM2-B72
1-D72
PATIENT ROOM2-B71
1-D73
PATIENT ROOM2-B70
1-D74
PATIENT ROOM2-B63
1-D75
PATIENT ROOM2-B62
1-D76
PATIENT ROOM2-B61
1-D77
PATIENT ROOM2-B60
1-D78
RESTROOM2-B67
1-D80
MEDICINE ROOM2-B53
1-D85
LAUNDRY ROOM2-B55
1-D86STORAGE
2-B57
1-D87
Room
1-D88
2-H10
1-D89
2-B43
1-D90
RESTROOM2-B77
1-D93RESTROOM
2-B81
1-D94
F F F F F F
B
B
B B
B
B
B
B B B
B
B
B
B
B B
B
B
B
B B
F
B
B
BF
B
B
B
F
B
BF
B
B
B
F
B
B B
F
A2 A2
A2 A2
A2 A2
A2 A2 A2
A2 A2 A2
A2 A2 A2
A2 A2 A2 A2 A2 A2
A2 A2 A2
A2 A2
A2 A2
A2
A2 A2
A2
A2 A2
A2
A2
A2
A2
A2
A2
A2
abcd
c c
aa
a
a
a
a a
A2
cG
cG
cG
c
cG
cG
dG
dG
d
G
d
G
dG
11
1 1 1 1
1
1
1
1
1 1
A2
A2
2
2
2
2 2
2
2
2
C2LHC C2HHC
2HHC
2LHCB
2LHCA
XFMR T2HC
33
4
4
4
4
4
4
4
4
A2 A2
A2
2
2HHC-3
2HHC-5
C2HHC-8
ADA RESTROOM2-B66
1-D96
ADA RESTROOM2-B68
1-D97
RESTROOM2-B65
1-D95
BB
D D
DD
B B
D
B
D
B
D
F
B
a
A2
A2
a
A2
a
A2 A2
FF
2
22
a a
2HHC-1
c
A2
cG
cG
f
JJ
Jf
ff
E-202.2B
2
J
J
J
J
J JJ J J
J J
KK
f
ff
f
f ff f f
f f
4
4
4
5
2LHCC-5
2LHCC
A2A2
A2
A2
A2A2A2 A2
A2 A2
A2 A2
A2
4
4
c
c
ccc
c
c c
ccc
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:10:4
3 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-102.2B
ELECTRICALLIGHTING PLAN AREA
2B
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1SECOND FLOOR LIGHTING PLAN - AREA B
KEYED NOTES - E-102.2B1 EXISTING THREE-WAY LIGHT SWITCH IN THIS
LOCATION TO BE RE-USED. SWITCH SHOWN TOILLUSTRATE LIGHTING CONTROL ONLY.
2 EXISTING NORMAL POWER LIGHTING CONTROLIN THIS SPACE TO BE REUSED. REMOVECRITICAL BRANCH SWITCH AND PROVIDE NEWDEVICE PLATE THAT BLANKS OFF SECONDSWITCH POSITION IN BOX.
3 PROVIDE UL 924 RELAY, ENTERTAINMENTNETWORKS #EPC-277,OAS, FOR CONTROL OFLS LIGHTING IN GROUP AREAS. CONNECT TOSWITCH LEG AS INDICATED.
4 CONNECT ACCENT LIGHTING BEHIND 3FORMPANELS TO CIRCUIT SERVING COMMON AREAGENERAL LIGHTING, TYP.
5 PROVIDE NEW LUTRON NOVA-T, OAS, 277VAC,ELECTRONIC LOW VOLTAGE DIMMER SWITCHFOR CONTROL OF ACCENT LIGHTING BEHIND3FORM PANELS.
GENERAL NOTES - E-102.2BA. SEE SHEET E-001 FOR ELECTRICAL LEGEND
AND ABBREVIATION. SEE ARCHITECT FORFINAL LUMINAIRE LOCATIONS.
B. ALL EMERGENCY LUMINAIRES AND EXITLIGHTS ARE TO REMAIN UNSWITCHED, UON.
C. LIGHTED EXIT SIGNS ARE SHOWN FORQUANTITIES AND GENERAL LOCATIONS.COORDINATE WITH ARCHITECT FOR EXACTLOCATION OF LIGHTED EXIST SIGNS.
D. SINGLE-FACE EXIT SIGNS ARE TYPE XA, UON.DOUBLE-FACE SIGNS ARE TYPE XB, UON.
E. COORDINATE ELECTRICAL WORK WITHARCHITECT, CIVIL, STRUCTURAL, MECHANICAL,AND PLUMBING SO AS TO AVOIDINTERFERENCE WITH OR COMPROMISE OFOTHER SYSTEMS.
F. SEE ENLARGED ELECTRICAL PLANS FORLOCATION OF LIGHTING BRANCH CIRCUITPANELBOARDS AND LIGHTING CONTACTORS.
G. LIFE SAFETY LIGHTING ON THIS SHEET ISSERVED FROM PANEL E1HHC. NUMBERINDICATES CIRCUIT NUMBER.
No. Description Date
REF.
2' - 6"
4' -
0"
2' -
8"
4' -
0"
2' -
8"
1-D00
1-D00
OFFICE1-D01
1-D01
OFFICE1-D02
1-D02
OFFICE1-D03
1-D03
OFFICE1-D04
1-D04
OFFICE1-D05
1-D05
CLASSROOM1-D06
1-D06
COMPUTER ROOM1-D07
1-D07
GAME ROOM1-D11
1-D11
MULTI-PURPOSE
1-D12
1-D12
LAUNDRY ROOM1-D13
1-D13
SECLUSION1-D14
1-D14GROUP ROOM
1-D15
1-D15
PATIENT ROOM1-D18
1-D18
PATIENT ROOM1-D19
1-D19
PATIENT ROOM1-D20
1-D20
PATIENT ROOM1-D21
1-D21
RESTROOM1-D23
1-D23
ADARESTROOM
1-D24
1-D24
ADARESTROOM
1-D25
1-D25
RESTROOM1-D26
1-D26
PATIENT ROOM1-D28
1-D28
PATIENT ROOM1-D29
1-D29
PATIENT ROOM1-D30
1-D30
PATIENT ROOM1-D31
1-D31
PATIENT ROOM1-D33
1-D33
PATIENT ROOM1-D34
1-D34
PATIENT ROOM1-D35
1-D35
MEDICINE ROOM1-D36
1-D36
CHART ROOM1-D37
1-D37
1-D40
1-D40
1-D42
1-D42
1-D44
1-D44
1-D46
1-D46
1-D48
1-D48
1-D50
1-D50
1-H06
1-H06
STAIR1-0S0F
1-0S0F
RESTROOM1-D35A
1-D35A
RESTROOM1-D32
1-D32
COMMON AREA1-H07
1-D92
2
GFCI C1LST-16
C1LST-4
GFCIGFCI
1LSTA-6
1LS
TA
1LS
TB
1HSTC1HST
C1LSTE1HST
XFMR T1ST
XFMR TECST(SUSPENEDABOVE)
+18" GFCI+18" GFCI+18" GFCI+18" GFCI
2
1LSTA-12
C
1LSTA-31
41LSTA-11
1LS
TC 1
E-201.1D 2
1LSTC-41LSTC-3
1LSTC-2
1LSTC-1
1LSTC-6
GFCI GFCI
Level 1100' - 0"
FIRST FLOOR0' - 0"
GFCI
J J J
K
K
5
6
7
8
9
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:10:4
9 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-201.1D
ELECTRICAL POWERPLAN AREA 1D
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
GENERAL NOTES - GE201A. SEE SHEET E-001 FOR ELECTRICAL LEGEND
AND ABBREVIATION.
B. REFER TO TELECOM DRAWINGS FORLOCATION OF TELECOM, SECURITY, A/VOUTLETS, ADDITIONAL POWER, AND OTHERCOMMUNICATIONS SYSTEMS DEVICES.COORDINATE WITH COMMUNICATION SUPPLIERFOR LOCATIONS AND REQUIREMENTS.
C. FINAL DIMENSIONS OF FLOOR BOX ANDPOKE-THROUGH LOCATIONS BY ARHC;COORDINATE WITH STRUCTURAL PRIOR TOPENETRATION OF STRUCTURAL SLAB.
D. ALL RECEPTACLES ARE MOUNTED 18", UON.VERIFY HEIGHT AND ALIGMENT OF DEVICESWITH ARCH DRAWINGS. COORDINATEOUTLET/RCPT LOCATIONS WITH MILL WORK,CASEWORK, ETC.
E. LOCATE ALL LOCAL DISCONNECT SWITCHESFOR MECHANICAL EQUIPMENT ADJACENT TO,BUT SEPARATE FROM, EQUIPMENT SERVED,PROVIDE SECURELY-ANCHORED METALFRAMING PER SECTION 260525.
F. CONNECT ALL CONTROL POWER TO VV BOXESON THIS PLAN TO CIRCUIT XXXXX. SEEMECHANICAL DRAWINGS FOR LOCATION ANDQUANTITIES. PROVIDE MOTOR RATED SNAPSWITCH AT ACCESSIBLE ABOVE CEILINGLOCATION, SEPARATE BUT ADJACENT TO VVBOXES.
G. CONNECT ALL FIRE/SMOKE AND SMOKEDAMPERS TO CIRCUIT XXXXX VIA FIRE ALARMSHUTDOWN RELAY.
H. UPDATE PANELBOARD SCHEDULES ATCOMPLETION OF PROJECT TO REFLECT FINALCIRCUIT NUMBERS AND DESCRIPTIONS.
1/8" = 1'-0"1FIRST FLOOR POWER PLAN - AREA D
KEYED NOTES - E-201.1D1 CONNECT NEW PANEL 1LSTC TO EXISTING
40A/2P CIRCUIT 1LSTA-38,40 WITH 3#8, #10G,3/4"C
2 CONNECT RECEPTACLES IN COMMON AREASTO LOAD SIDE OF GFCI RECEPTACLE SHOWNAT NURSES STATION TO PROVIDE GFCIPROTECTION TO RECEPTACLES IN COMMONPATIENT AREA.
4 SAW CUT EXISTING SLAB TO INSTALL CONDUITTO NURSE STATION ISLAND FURNITURE.COORDINATE WITH ARCHITECT FOR CUTTINGAND PATCHING REQUIREMENTS.
5 TYPE K UNDERCABINET LIGHT, TYP
6 TYPE J ACCENT LIGHT BEHIND 3FORM PANEL,TYP
7 RECEPTACLE FOR MICROWAVE
8 RECEPTACLE FOR ICE MAKER
9 RECEPTACLE FOR REFRIGERATOR
1/2" = 1'-0"2
NOURISHMENT STATION ELECTRICALELEVATION - UNIT 1D
Notes:
Total Amps: 15 A 13 A
Total Load: 1588 VA 1380 VA
-- 29 SPACE -- -- 0 VA / 0 VA -- -- SPACE 30 --
-- 27 SPACE -- -- 0 VA / 0 VA -- -- SPACE 28 --
-- 25 SPACE -- -- 0 VA / 0 VA -- -- SPACE 26 --
-- 23 SPACE -- -- 0 VA / 0 VA -- -- SPACE 24 --
-- 21 SPACE -- -- 0 VA / 0 VA -- -- SPACE 22 --
-- 19 SPACE -- -- 0 VA / 0 VA -- -- SPACE 20 --
-- 17 SPACE -- -- 0 VA / 0 VA -- -- SPACE 18 --
-- 15 SPACE -- -- 0 VA / 0 VA -- -- SPACE 16 --
-- 13 SPACE -- -- 0 VA / 0 VA -- -- SPACE 14 --
-- 11 SPACE -- -- 0 VA / 0 VA -- -- SPACE 12 --
-- 9 SPACE -- -- 0 VA / 0 VA -- -- SPACE 10 --
-- 7 SPACE -- -- 0 VA / 0 VA -- -- SPACE 8 --
2#12, #12G, 3/4"C 5UNDERCABINET LIGHTINGNOURISHMENT STATION...
20 A 1 128 VA / 360 VA 1 20 A RECEPTACLES RM 1-D37 6 2#12, #12G, 3/4"C
2#12, #12G, 3/4"C 3RECEPTACLESNOURISHMENT STATION
20 A 1 180 VA / 1200 VA 1 20 AMICROWAVENOURISHMENT STATION...
4 2#12, #12G, 3/4"C
2#12, #12G, 3/4"C 1 REFRIGERATOR UNIT 1D 20 A 1 500 VA / 600 VA 1 20 AICE MAKER NOURISHMENTSTATION
2 2#12, #12G, 3/4"C
Wire & ConduitCktNo. Circuit Description Trip Poles
A BPoles Trip Circuit Description
CktNo. Wire & Conduit
Notes:
Enclosure: NEMA 1
Mounting: Surface A.I.C. Rating: 10,000 MLO: No
Supply From: 1LSTA Phases: 1 MCB: No MCB Neutral Rating: 100.00%
Location: 1-D46 1-D46 Volts: 120/208 Single Bus Rating: 100A Feed Through: Yes
Branch Panel: 1LSTC
No. Description Date
RE
F.
JS
PATIENT ROOM2-B80
1-D38
2-OSOA
1-D51
2-EL6
1-D52
OFFICE2-B44
1-D53
OFFICE2-B45
1-D54
OFFICE2-B47
1-D55
MECHANICALROOM2-B49
1-D56
GROUP ROOM2-B51
1-D57
WORK LOUNGE2-B52
1-D58
OFFICE2-B50
1-D59
OFFICE2-B48
1-D60
OFFICE2-B46
1-D61
2-B81
1-D62
PATIENT ROOM2-B78
1-D63
PATIENT ROOM2-B76
1-D64
PATIENT ROOM2-B75
1-D65
COMMON AREA2-H1
1-D66
SECLUSIONROOM2-B54
1-D67
OFFICE2-B56
1-D68
2-B74RESTROOM
1-D69
PATIENT ROOM2-B73
1-D70
2-OSOOD
1-D71
PATIENT ROOM2-B72
1-D72
PATIENT ROOM2-B71
1-D73
PATIENT ROOM2-B70
1-D74
PATIENT ROOM2-B63
1-D75
PATIENT ROOM2-B62
1-D76
PATIENT ROOM2-B61
1-D77
PATIENT ROOM2-B60
1-D78
RESTROOM2-B67
1-D80
MEDICINE ROOM2-B53
1-D85
LAUNDRY ROOM2-B55
1-D86
STORAGE2-B57
1-D87
Room
1-D88
2-H10
1-D89
2-B43
1-D90
RESTROOM2-B77
1-D93
RESTROOM2-B81
1-D94
GFCI2LHCB-20
C2LHC-16
C2LHC-2
GFCI
GFCI
C2LHD-6
C2LHD-4C2LHD-2
2LHCA-5
3
2
4
XFMR T2HC
2LHCA
2LHCB
2HHCC2HHCC2LHC
ELECTROOM2-284
2LHCA-6
GFCI GFCI GFCI
2
2LHCA-354
5
RESTROOM2-B65
1-D95
ADA RESTROOM2-B66
1-D96ADA RESTROOM2-B68
1-D97
C2LHD
5
2LHCC
1
E-202.2B
2
2LHCC-1
2LHCC-2
2LHCC-3
2LHCC-4
GFCI
GFCIGFCI
GFCI
2LHCC-6
2LHCC-72LHCC-8
J J J
GFCI
K
K
6
7
8
9
10
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:10:5
5 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-202.2B
ELECTRICAL POWERPLAN AREA 2B
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1SECOND FLOOR POWER PLAN - AREA B
KEYED NOTES - E-202.2B1 CONNECT NEW PANEL 2LHCC TO EXISTING
40A/2P CIRCUIT 2LHCB-29,31 WITH 3#8, #10G,3/4"C
2 CONNECT RECEPTACLES IN COMMON AREASTO LOAD SIDE OF GFCI RECEPTACLE SHOWNAT NURSES STATION TO PROVIDE GFCIPROTECTION TO RECEPTACLES IN COMMONPATIENT AREA.
3 JUNCTION BOX FOR POWER TO TV MONITORMOUNT BOX ABOVE CEILING AND HARD WIRETELEVISION POWER CORD TO BOX. USEAPPROPRIATE FLEXIBLE CORD STRAIN RELIEFTERMINATION FOR TV POWER CORD IN BOXPROVIDE SWITCH AS INDICATED FOR LOCALDISCONNECT OF TV POWER FORMAINTENANCE.
4 RECEPTACLE FOR POWER TO NURSECOMPUTER WORKSTATION. COORDINATEWITH ARCHITECT FOR EXACT LOCATION ANDMETHOD OF CONNECTION.
5 STUB UP CONDUIT FOR NURSE STATIONCOUNTER FROM BELOW.
6 TYPE K UNDERCABINET LIGHT, TYP
7 RECEPTACLE FOR MICROWAVE.
8 RECEPTACLE FOR ICE MAKER.
9 RECEPTACLE FOR REFRIGERATOR.
10 TYPE J ACCENT LIGHT BEHIND 3FORM PANEL,TYPICAL.
GENERAL NOTES - E-202.2BA. SEE SHEET E-001 FOR ELECTRICAL LEGEND
AND ABBREVIATIONS.
1/2" = 1'-0"2
NOURISHMENT STATION ELECTRICALELEVATION - UNIT 2B
Notes:
Total Amps: 23 A 15 A
Total Load: 2520 VA 1580 VA
-- 29 SPACE -- -- 0 VA / 0 VA -- -- SPACE 30 --
-- 27 SPACE -- -- 0 VA / 0 VA -- -- SPACE 28 --
-- 25 SPACE -- -- 0 VA / 0 VA -- -- SPACE 26 --
-- 23 SPACE -- -- 0 VA / 0 VA -- -- SPACE 24 --
-- 21 SPACE -- -- 0 VA / 0 VA -- -- SPACE 22 --
-- 19 SPACE -- -- 0 VA / 0 VA -- -- SPACE 20 --
-- 17 SPACE -- -- 0 VA / 0 VA -- -- SPACE 18 --
-- 15 SPACE -- -- 0 VA / 0 VA -- -- SPACE 16 --
-- 13 SPACE -- -- 0 VA / 0 VA -- -- SPACE 14 --
-- 11 SPACE -- -- 0 VA / 0 VA -- -- SPACE 12 --
-- 9 SPACE -- -- 0 VA / 0 VA -- -- SPACE 10 --
2#12, #12G, 3/4"C 7 RECEPTACLES RM 2-B56 20 A 1 720 VA / 180 VA 1 20 A RECEPTACLE RM 2-H1 8 2#12, #12G, 3/4"C
2#12, #12G, 3/4"C 5UNDERCABINET LIGHTINGNOURISHMENT STATION...
20 A 1 0 VA / 720 VA 1 20 A RECEPTACLES RM 2-B51 6 2#12, #12G, 3/4"C
2#12, #12G, 3/4"C 3RECEPTACLENOURISHMENT STATION...
20 A 1 180 VA / 500 VA 1 20 AREFRIGERATORNOURISHMENT STATION...
4 2#12, #12G, 3/4"C
2#12, #12G, 3/4"C 1MICROWAVENOURISHMENT STATION...
20 A 11200 VA / 600
VA1 20 A
ICE MAKER NOURISHMENTSTATION UNIT 2B
2 2#12, #12G, 3/4"C
Wire & ConduitCktNo. Circuit Description Trip Poles
A BPoles Trip Circuit Description
CktNo. Wire & Conduit
Notes:
Enclosure: NEMA 1
Mounting: Surface A.I.C. Rating: 10,000 MLO: No
Supply From: 2LHCB Phases: 1 MCB: No MCB Neutral Rating: 100.00%
Location: Volts: 120/208 Single Bus Rating: 100A Feed Through: Yes
Branch Panel: 2LHCC
No. Description Date
1-D00
1-D00
OFFICE1-D01
1-D01
OFFICE1-D02
1-D02
OFFICE1-D03
1-D03
OFFICE1-D04
1-D04
OFFICE1-D05
1-D05
CLASSROOM1-D06
1-D06
COMPUTER ROOM1-D07
1-D07
GAME ROOM1-D11
1-D11
MULTI-PURPOSE
1-D12
1-D12
LAUNDRY ROOM1-D13
1-D13
SECLUSION1-D14
1-D14
GROUP ROOM1-D15
1-D15
PATIENT ROOM1-D18
1-D18
PATIENT ROOM1-D19
1-D19
PATIENT ROOM1-D20
1-D20
PATIENT ROOM1-D21
1-D21
RESTROOM1-D23
1-D23
ADARESTROOM
1-D24
1-D24
ADARESTROOM
1-D25
1-D25
RESTROOM1-D26
1-D26
PATIENT ROOM1-D28
1-D28
PATIENT ROOM1-D29
1-D29
PATIENT ROOM1-D30
1-D30
PATIENT ROOM1-D31
1-D31
PATIENT ROOM1-D33
1-D33
PATIENT ROOM1-D34
1-D34
PATIENT ROOM1-D35
1-D35
MEDICINE ROOM1-D36
1-D36
CHART ROOM1-D37
1-D37
1-D40
1-D40
1-D42
1-D42
1-D44
1-D44
1-D46
1-D46
1-D48
1-D48
1-D50
1-D50
1-H06
1-H06
STAIR1-0S0F
1-0S0F
RESTROOM1-D35A
1-D35A
RESTROOM1-D32
1-D32
COMMON AREA1-H07
1-D92
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:11:0
1 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-301.1D
ELECTRICAL FIREALARM PLAN AREA
1D
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1FIRST FLOOR FIRE ALARM PLAN - AREA D
GENERAL NOTES - E-301.1DA. SEE E-001 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
B. PROVIDE FA SYSTEM COMPONENTS COMPATIBLE WITHEXISTING FIRE ALARM SYSTEM IN THE BUILDING INCOMPLIANCE W/NFPA 72 FIRE ALARM CODE AND NFPA101 LIFE SAFETY CODE AND SECTION 28 31 00.
C. INSTALL FA NOTIFICATION DEVICES IAW NFPA 72.MOUNT VISUAL & COMBINATION NOTIFICATIONDEVICES IN CEILING PREFERABLY OR ON WALL WITHENTIRE LENS BETWEEN 80" & 96"AFF.
D. COORD DUCT DETECTOR LOCATIONS W/DIV 23 FORHVAC DUCTWORK, AHU'S, FCU'S & FSD'S ASAPPLICABLE. PLACE DUCT DETECTOR IN STRAIGHTDUCT WITHIN 5-FEET OF FSD. WHERE POSSIBLE, PLACEDUCT DETECTORS IN UPSTREAM AIRFLOW SIDE OFFSD. SEE MECHANICAL SHEETS & DETAILS FOR HVACDUCTWORK & EQUIPMENT LOCATIONS.
E. COORD DETECTORS & DEVICE LOCATIONS IN FINISHEDSPACES WITH ARCH REFLECTED CEILING PLAN (RCP).RELOCATE FA DETECTORS & DEVICES TO RESOLVEINTERFERENCE & CONFLICTS, FINAL LOCATION SHALLCONFORM TO NFPA 72 AND UL REQUIREMENTS.
F. ALIGN FIRE ALARM ZONES TO SMOKE COMPARTMENTSPER NFPA REQUIREMENTS.
No. Description Date
RE
F.
4' -
0"
2' -
8"
4' -
0"
2' -
8"
2' - 6"
PATIENT ROOM2-B80
1-D38
2-OSOA
1-D51
2-EL6
1-D52
OFFICE2-B44
1-D53
OFFICE2-B45
1-D54
OFFICE2-B47
1-D55
MECHANICALROOM2-B49
1-D56
GROUP ROOM2-B51
1-D57WORK LOUNGE
2-B52
1-D58
OFFICE2-B50
1-D59
OFFICE2-B48
1-D60
OFFICE2-B46
1-D61
2-B81
1-D62
PATIENT ROOM2-B78
1-D63
PATIENT ROOM2-B76
1-D64
PATIENT ROOM2-B75
1-D65
COMMON AREA2-H1
1-D66
SECLUSIONROOM2-B54
1-D67
OFFICE2-B56
1-D68
2-B74RESTROOM
1-D69
PATIENT ROOM2-B73
1-D70
2-OSOOD
1-D71
PATIENT ROOM2-B72
1-D72
PATIENT ROOM2-B71
1-D73
PATIENT ROOM2-B70
1-D74
PATIENT ROOM2-B63
1-D75
PATIENT ROOM2-B62
1-D76
PATIENT ROOM2-B61
1-D77
PATIENT ROOM2-B60
1-D78
RESTROOM2-B67
1-D80
MEDICINE ROOM2-B53
1-D85
LAUNDRY ROOM2-B55
1-D86STORAGE
2-B57
1-D87
Room
1-D88
2-H10
1-D89
2-B43
1-D90
RESTROOM2-B77
1-D93RESTROOM
2-B81
1-D94
RESTROOM2-B65
1-D95
ADA RESTROOM2-B66
1-D96
ADA RESTROOM2-B68
1-D97
NORTHNORTH
0'
TA
S
E OF TEXAS
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JOSEPH R. ROUTHIER
96742
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
HealthcareHealthcareHealthcareHealthcare
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/16/2015
9/1
6/2
015 4
:11:0
7 P
MC
:\R
evit\1
042-0
07-0
4_E
lec_R
15_jrouth
ier.
rvt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RI C
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TIO
NS
E-302.2B
ELECTRICAL FIREALARM PLAN AREA
2B
JRR
FL
SEPTEMBER 16, 2015
14265
PBK Architects
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1SECOND FLOOR FIRE ALARM PLAN - AREA B
GENERAL NOTES - E-303.2BA. SEE E-001 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
B. PROVIDE FA SYSTEM COMPONENTS COMPATIBLE WITHEXISTING FIRE ALARM SYSTEM IN THE BUILDING INCOMPLIANCE W/NFPA 72 FIRE ALARM CODE AND NFPA101 LIFE SAFETY CODE AND SECTION 28 31 00.
C. INSTALL FA NOTIFICATION DEVICES IAW NFPA 72.MOUNT VISUAL & COMBINATION NOTIFICATIONDEVICES IN CEILING PREFERABLY OR ON WALL WITHENTIRE LENS BETWEEN 80" & 96"AFF.
D. COORD DUCT DETECTOR LOCATIONS W/DIV 23 FORHVAC DUCTWORK, AHU'S, FCU'S & FSD'S ASAPPLICABLE. PLACE DUCT DETECTOR IN STRAIGHTDUCT WITHIN 5-FEET OF FSD. WHERE POSSIBLE, PLACEDUCT DETECTORS IN UPSTREAM AIRFLOW SIDE OFFSD. SEE MECHANICAL SHEETS & DETAILS FOR HVACDUCTWORK & EQUIPMENT LOCATIONS.
E. COORD DETECTORS & DEVICE LOCATIONS IN FINISHEDSPACES WITH ARCH REFLECTED CEILING PLAN (RCP).RELOCATE FA DETECTORS & DEVICES TO RESOLVEINTERFERENCE & CONFLICTS, FINAL LOCATION SHALLCONFORM TO NFPA 72 AND UL REQUIREMENTS.
F. ALIGN FIRE ALARM ZONES TO SMOKE COMPARTMENTSPER NFPA REQUIREMENTS.
No. Description Date
PLUMBING PIPE MATERIALS SPECIFICATION
SERVICE
EQUIPMENT DRAINSAND OVERFLOWS
SANITARY DRAINAGEAND VENT ABOVEGRADE INCLUDINGCRAWL SPACE
SANITARY DRAINAGEAND VENT BELOWGRADE
DOMESTIC WATER,ABOVE GRADE
PIPE
TYPE "L" HARD DRAWN COPPER (ASTM B88)
SERVICE WEIGHT CAST IRON, CISPI 301
TYPE "L" HARD DRAWN COPPER (ASTM B88)
FITTING
SOLDERED (95-5) WROUGHT COPPER, ANSI B16.22.
SERVICE WEIGHT DWV NO-HUB FITTINGS. HEAVY WEIGHT NO-HUB, 4-BAND COUPLINGS FOR SIZES 4" & LESS AND 6-BANDCOUPLINGS FOR PIPES SIZES OVER 4". CONFORMING TO CISPI310 MANUF. BY ANACO "HUSKEY",2000, MIFAB MI-XHUB ORCLAMP-ALL 125. NO-HUB CISPI 310 COUPLINGS. ALL COUPLINGSWITH STAINLESS STEEL BANDS AND NEOPRENE GASKETS
SERVICE WEIGHT BELL & SPIGOT DWV FITTINGSWITH NEOPRENE GASKETS, ASTM C564.
ANSI B16.22 WROUGHT COPPER WITH 95-5 SOLDERLEAD-FREE JOINTS, ASTM B32.
UNIONS: CLASS 150, 300 POUND WATER-OIL-GAS SERVICE BRONZE. UNION WITH GROUND JOINTAND BRASS SEAT, ANSI B16.39.
NOTE: REFER TO DIVISION 22 SPECIFICATIONS FOR MORE DETAILED SPECIFICATIONS OF PIPE AND FITTINGS.
SERVICE WEIGHT CAST IRON, CISPI 301
GENERAL NOTES
PRIOR TO WORK CONTRACTOR SHALL TIGHTLY COORDINATE PLUMBING WORK WITH OTHER TRADES.
PROVIDE A UNION DOWNSTREAM FROM EACH THREADED VALVE.
PROVIDE A SEPARATE P-TRAP AT EACH PLUMBING FIXTURE, UNLESS TRAP IS BUILT INTO FIXTURE.
REFER TO ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS.
MAKE ROUGH-IN AND FINAL CONNECTION TO ALL PLUMBING FIXTURES.
ALL NEW WORK SHALL CONFORM TO THE 2009 EDITION OF THE INTERNATIONAL PLUMBING CODE UNLESS OTHERWISE NOTED OR SHOWN.
DRAWINGS ARE DIAGRAMMATIC IN NATURE, NOT ALL REQUIRED PIPE ELBOWS, TEES, AND ASSOCIATED FITTINGS ARE SHOWN. CONTRACTOR SHALL PROVIDE ACOMPLETE WORKING PLUMBING SYSTEM PER THE SPECIFICATIONS AND PLUMBING CODE.
FIRE PROTECTION PIPING SHALL BE COORDINATED AROUND OTHER TRADES, SUCH AS PLUMBING, HVAC AND ELECTRICAL.
A SUPERVISORY SWITCH (TAMPER SWITCH) SHALL BE PROVIDED ON EACH VALVE USED FOR CONTROLLING THE FIRE PROTECTION SYSTEM FOR THE STANDPIPE ANDSPRINKLER SYSTEM, AS SPECIFIED.
CONTRACTOR SHALL OBTAIN ARCHITECT/ENGINEER APPROVAL FOR ALL ACCESS PANEL LOCATIONS.
PROVIDE AN ISOLATION VALVE FOR EACH SINGLE PLUMBING FIXTURE, OR WHERE FIXTURES ARE GROUPED ONE VALVE PER GROUP, REFER TO FLOOR PLANS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
PLUMBING LEGEND
SYMBOLSYMBOL ABBREV. DESCRIPTION ABBREV. DESCRIPTION
SANITARY
DOMESTIC HOT WATER (110°F)
DOMESTIC COLD WATER
DHW
DCW
VENT
ABOVE FINISHED FLOORAFF
BALL VALVE
UNIONSANSAN
ACCESS PANELAP
FEET PER SECONDFPS
GALLONS PER MINUTEGPM
BOTTOM OF PIPEBOP
WALL CLEANOUTWCO
PLUMBING FIXTURE SPECIFICATIONS
SINK: SINGLE COMPARTMENT SINK, ELKAY MODEL LRAD1716, 17" X 16" X 5-1/2" DEEP, ADA COMPLIANT, SELF RIMMING, SINGLE COMPARTMENT SINK, WITH UNDERCOATING, 18-GAGE, TYPE302 STAINLESS STEEL WITH THREE FAUCET HOLES ON 4 INCH CENTERS.
FAUCET: ELKAY NO. LK402T4, DECK MOUNTED 4" CENTER INTEGRAL SPOUT, CHROME PLATED BRASS, MANUALLY OPERATED, ADA COMPLIANT, 2 HOLE MOUNTING, 2.2 GPM FLOW, 4"WRISTBLADE HANDLES, QUARTER TURN CERAMIC.
SUPPLIES: CHICAGO NO. 1006.CP. SUPPLY WITH ESCUTCHEON 1/2" OD X 12" BULLNOSE FLEX SUPPLY RISER, 1/2" NPT FEMALE THREADED INLET & LOOSE KEY ANGLE STOP, CHROMEPLATED FINISH, COMPRESSION CONNECTIONS NOT ALLOWED.
P-TRAP: MCGUIRE NO. 8912, CHROME PLATED 1 1/2" ADJUSTABLE CAST BRASS P-TRAP WITH TUBING TO WALL, GROUND SWIVEL JOINT CLEANOUT PLUG WITH CAST BRASS ESCUTCHEON,ALL CHROME PLATED.
DRAIN: ELKAY MODEL LK18B WITH ELKAY MODEL LKADOS. TYPE 304 STAINLESS STEEL STRAINER WITH OFFSET TAILPIECE.
INSULATION KIT: TRUEBRO, FULLY MOLDED CLOSED SELL VINYL, ADA APPROVED INSULATION KIT COMPLETE WITH INTERLOCKING TRAP ASSEMBLY, HOT AND COLD-WATER ANGLEVALVE ASSEMBLY AND FACTORY-SUPPLIED FASTENERS.
NUTRITION STATION (NS-1) - REFER TO ARCHITECT DRAWINGS FOR DIMENSIONS
1.
2.
3.
4.
5.
6.
BOWL: WALL MOUNTED BATHROOM SINK, AMERICAN STANDARD "MURRO", 22" X 18" X 34" WITH OVERFLOW, WHITE VITREOUS CHINA WITH SINGLE HOLE PLUGGED.ADA COMPLIANT. WITH VITREOUS CHINA SHROUD, 0059.02EC.
FAUCET: SLOAN MODEL BASYS IR SERIES EFX 800-200-1000 CP SENSOR METERING HANDWASHING FAUCET WALL MOUNTED SET TO 10 SECOND PROGRAMMABLERUN TIME PER EACH USE. ADA COMPLIANT, .5 GPM FLOW CONTROL, BATTERY OPERATED CHROME FINISH WITH ASSE 1070 THERMOSTATIC MIXING VALVE IN WALL.
SUPPLIES: CHICAGO NO. 1006.CP. SUPPLY WITH ESCUTCHEON 1/2" OD X 12" BULLNOSE FLEX SUPPLY RISER, 1/2" NPT FEMALE THREADED INLET & LOOSE KEYANGLE STOP, CHROME PLATED FINISH, COMPRESSION CONNECTIONS NOT ALLOWED.
P-TRAP: KOHLER K-8998, CHROME PLATED 1 1/2" ADJUSTABLE CAST BRASS P-TRAP WITH TUBING TO WALL, GROUND SWIVEL JOINT CLEANOUT PLUG WITH CASTBRASS ESCUTCHEON, ALL CHROME PLATED AND CONCEALED WITHIN LAVATORY.
DRAIN: ELKAY MODEL LK18B WITH ELKAY MODEL LKADOS. TYPE 304 STAINLESS STEEL STRAINER WITH OFFSET TAILPIECE.
INSULATION KIT: TRUEBRO, FULLY MOLDED CLOSED SELL VINYL, ADA APPROVED INSULATION KIT COMPLETE WITH INTERLOCKING TRAP ASSEMBLY, HOT ANDCOLD-WATER ANGLE VALVE ASSEMBLY AND FACTORY-SUPPLIED FASTENERS.
LAVATORY (L-1)
1.
2.
3.
4.
5.
6.
ZURN Z5647-BWL, FLOOR MOUNTED BACK OUTLET WATER CLOSET WITH BACK SPUD WATER INLET CONNECTION. ELONGATED FLUSH VALVE TOILET, VITREOUS CHINA, 1.28 GPF,SIPHON JET FLUSH. EQUIP WITH CHURCH #9500C OPEN FRONT SEAT. EQUIP WITH CONCEALED MANUAL OPERATED FLUSH VALVE ZURN ZH615AV-HET-MB-WP AQUAVANTAGE WITHHYDRAULIC PUSH BUTTON ACTUATION AT 1.28 GPF, OR APPROVED EQUAL WITH SPUD COUPLING AND FLANGE FOR BACK SPUD CONNECTION WITH WALL PLATE FOR FLUSHVALVE. PROVIDE SLOAN WB-1-A WALL BOX WITH PUSH BUTTON ACTUATOR (HY-33-A).
WATER CLOSET (WC-1)
1.
SHOWER HEAD: MATCH EXISTING SHOWER HEADS INSTALLED IN PATIENT RESTROOMS OF AREA B OF THIS FACILITY FOR NEW SHOWERS. FOR EXISTING SHOWERS TO BERENOVATED EXISTING SHOWER HEADS ARE TO REMAIN. REFER TO P-100.B1 AND P-200.B1 FOR DEMOLITION AND RENOVATION OF SHOWERS.
DRAIN: FOR EXISTING SHOWERS TO BE RENOVATED, REUSE EXISTING DRAIN. FOR NEW SHOWERS, PROVIDE Mi-Fab No. F1100C-6-1, CAST IRON FLOOR DRAIN WITH FLASHINGCOLLAR, SEEPAGE FLANGE, NICKEL BRONZE 6 INCH ROUND ADJUSTABLE STRAINER WITH SQUARE HOLES.
SHOWER VALVE: SPEAKMAN BEHAVIORAL SAFETY PRODUCTS #SV220. SHOWER VALVE WITH ANTI-LIGATURE HANDLE AND ESCUTCHEON PLATE. ANTI-SCALD PROTECTIONCHROME PLATED WITH INTEGRAL STOPS. ADA COMPLIANT.
SHOWER (SH-1)
1.
2.
3.
HAND SINK (SK-1)
1.
2.
3.
SINK: SINGLE COMPARTMENT SINK, ELKAY MODEL LRAD1720, 17" X 20" X 5-1/2" DEEP, ADA COMPLIANT, SELF RIMMING, SINGLE COMPARTMENT SINK, WITHUNDERCOATING, 18-GAGE, TYPE 302 STAINLESS STEEL WITH THREE FAUCET HOLES ON 4 INCH CENTERS.
FAUCET: CHICAGO NO. 786-GN8FC, DECK MOUNTED CHROME PLATED BRASS FAUCET, WITH SWING GOOSENECK SPOUT, INLETS ON 8 INCH CENTERS, CHROMEPLATED BRASS 4 INCH WRIST BLADE HANDLES, WITH 1/2 INCH INLETS, 1.5 GPM FLOW CONTROL DEVICE, QUARTER TURN CARTRIDGES, AND ADA COMPLIANT.
SUPPLIES, P-TRAP, DRAIN AND INSULATION KIT: SAME AS NS-1.
FURNISH AND INSTALL HOOK-UP BOX, CONSTRUCTED OF 20 GAUGE STEEL, RECESSED PAINTED TO MATCH WALL, WITH 1/2" CHROME PLATED ANGLE VALVE, MANUFACTURED BYGUY GRAY NO. BIM875 OR EQUAL, WITH 5-MICRON CARTRIDGE TYPE FILTER AND HOUSING TO BE INSTALLED BETWEEN ANGLE VALVE AND EQUIPMENT. MOUNT TOP OF BOX AT 15"ABOVE FINISHED FLOOR.
ROUGH-IN BOX (RB-1)
1.
RECESSED HOOK-UP BOX CONSTRUCTED OF 20 GAUGE STEEL, PAINTED TO MATCH WALL, WITH (2) 1/2" BRASS ANGLE VALVES, MANUFACTURED BY GUY GRAY NO. B 200, ORAPPROVED EQUAL.
WASHING MACHINE BOX (WB-1)
1.
DRAWING LIST INFORMATION - PLUMBING
SheetNumber Sheet Name
CurrentRevision
CurrentRevision Date Current Revision Description
FP-101.1D FIRE PROTECTION FIRST FLOOR AREA D
FP-102.2B FIRE PROTECTION SECOND FLOOR AREA B
P-001 PLUMBING LEGEND, GENERAL NOTES AND SPECIFICATIONS
P-101.1D PLUMBING DEMOLITION FIRST FLOOR AREA D
P-102.2B PLUMBING DEMOLITION SECOND FLOOR AREA B
P-201.1D PLUMBING RENOVATION FIRST FLOOR AREA D
P-202.2B PLUMBING RENOVATION SECOND FLOOR AREA B
P-800 PLUMBING DETAILS
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:0
6 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
P-001
PLUMBING LEGEND,GENERAL NOTES AND
SPECIFICATIONS
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
No. Description Date
P RRRRRRRRRRRRRRRRRRRRRRREEEEEEEEEEEEE
EEEEEEEEEEEEEEEENNNNNNIIIIIIIIIIII
GGGGGGGGGGGGGGGGGGGGGNNNNNNNNNNNNNNNEEEEEELLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAANNNOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOISSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
FFFFFFFFFFFFFFFFFFFFFFFFFFFOOOOOOOOOOOOOOOOOOOOOOOOO
R
EEEEEEEEEEEEEEEEEEEEEEEEEEEEELLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL I CCCCCCCCCCCCCCCCCCCCCCCC E NNNNNNNNNNNNNNNNNNNNNNNNN SSSSSSSSSSSSSSSSSSSSSS EEEEEEEEEEEEEEEEEEEEEEEE DDDDDDDDDDDDDDDDDDDD
67131313131313131313131313131313131313131313131313131377777777777777777777777777777
09/16/2016
2
3
2
1 1
22
3
3
3
4
4
2
2
5
5
PATIENT ROOM1-D18
PATIENT ROOM1-D19
PATIENT ROOM1-D20
PATIENT ROOM1-D21
PATIENT ROOM1-D28
PATIENT ROOM1-D29
PATIENT ROOM1-D30
PATIENT ROOM1-D31
STAIR1-0S0F
RESTROOM1-D32
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
RESTROOM1-D35A
MEDICINE ROOM1-D36
CHART ROOM1-D37
COMMON AREA1-H07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12SECLUSION
1-D14
GROUP ROOM1-D15
LAUNDRY ROOM1-D13
ADARESTROOM
1-D25
ADARESTROOM
1-D24
GENERAL NOTESPLUMBING ITEMS SHOWN LIGHT ARE EXISTING TO REMAIN.ITEMS SHOWN BOLD ARE TO BE REMOVED.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO WORK.
COORDINATE DOWNTIME OF SYSTEMS WITH OWNER PRIORTO WORK.
A.
B.
C.
1/8" = 1'-0"1
PLUMBING DEMOLITION FIRSTFLOOR AREA D
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:0
7 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
P-101.1D
PLUMBINGDEMOLITION FIRST
FLOOR AREA D
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
KEYED NOTES - P-101.1D1 REMOVE EXISTING LAVATORY AND LAVATORY
TRIM AND ASSOCIATED PLUMBING. CAPSANITARY LINE AND WATER PIPING ANDCONCEAL IN WALL.
2 REMOVE EXISTING FLOOR MOUNTED WATERCLOSET. CAP SANITARY WASTE BELOW SLABAND FILL VOID IN FLOOR WITH CONCRETE,MATCH EXISTING SLAB THICKNESS AND FINISH.REFER TO RENOVATION DRAWING P201.B2 FORNEW WATER CLOSET WITH WALL OUTLET.
3 REMOVE EXISTING BATH TUB/SHOWER.REMOVE DCW AND DHW PIPING AND CAPABOVE CEILING.
4 REMOVE EXISTING LAVATORY ANDASSOCIATED TRIM. EXISTING DCW ANDSANITARY/VENT ARE TO REMAIN FORCONNECTION TO NEW FIXTURE. REFER TORENOVATION DRAWINGS.
5 REMOVE EXISTING BATH TUB/SHOWER.EXISTING DCW AND SANITARY/VENT ARE TOREMAIN FOR CONNECTION TO NEW FIXTURE.REFER TO RENOVATION DRAWINGS.
No. Description Date
09/16/2016
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
67137
09/16/2016
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
OFFICE2-B56
SECLUSION ROOM2-B54
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
GROUP ROOM2-B51
WORK LOUNGE2-B52
PATIENT ROOM2-B80
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
PATIENT ROOM2-B73
STORAGE2-B57
2
3
2
1 1
22
3
3
3
5
5
5 6
6
2
2
2
6
4
4
1/8" = 1'-0"1
PLUMBING DEMOLITION SECONDFLOOR AREA B
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:0
9 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
P-102.2B
PLUMBINGDEMOLITION SECOND
FLOOR AREA B
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
GENERAL NOTESPLUMBING ITEMS SHOWN LIGHT ARE EXISTING TO REMAIN.ITEMS SHOWN BOLD ARE TO BE REMOVED.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO WORK.
COORDINATE DOWNTIME OF SYSTEMS WITH OWNER PRIORTO WORK.
A.
B.
C.
KEYED NOTES - P-102.2B1 REMOVE EXISTING LAVATORY AND LAVATORY
TRIM AND ASSOCIATED PLUMBING. CAPSANITARY LINE AND WATER PIPING ANDCONCEAL IN WALL.
2 REMOVE EXISTING FLOOR MOUNTED WATERCLOSET. CAP SANITARY WASTE BELOW SLABAND FILL VOID IN FLOOR WITH CONCRETE,MATCH EXISTING SLAB THICKNESS AND FINISH.REFER TO RENOVATION DRAWING P201.B2 FORNEW WATER CLOSET WITH WALL OUTLET.
3 REMOVE EXISTING BATH TUB/SHOWER.REMOVE DCW AND DHW PIPING AND CAPABOVE CEILING.
4 REMOVE EXISTING HAND SINK AND CAPEXISTING PLUMBING CONNECTIONS FORCONNECTION TO NEW FIXTURE.
5 REMOVE EXISTING LAVATORY AND LAVATORYTRIM. EXISTING DCW AND SANITARY/VENT ARETO REMAIN FOR CONNECTION TO NEWFIXTURE. REFER TO RENOVATION DRAWINGS.
6 REMOVE EXISTING BATH TUB/SHOWER.EXISTING DCW AND SANITARY/VENT ARE TOREMAIN FOR CONNECTION TO NEW FIXTURE.REFER TO RENOVATION DRAWINGS.
No. Description Date
09/16/2016
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
67137
09/16/2016
REF.
PATIENT ROOM1-D30
PATIENT ROOM1-D29
PATIENT ROOM1-D28
PATIENT ROOM1-D21
PATIENT ROOM1-D20
PATIENT ROOM1-D19
1-D00
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14
GROUP ROOM1-D15
PATIENT ROOM1-D18
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36
CHART ROOM1-D37
1-D40
1-D42
1-D44
1-D46
1-D48
1-D50
1-H06
STAIR1-0S0F
RESTROOM1-D35A
RESTROOM1-D32
COMMON AREA1-H07
OFFICE1-D01
1
2
3
11
1
2
22
3
33
WC-1
L-1
SH-1
WC-1
L-1
SH-1
SH-1 SH-1
L-1
WC-1WC-1
L-1
NS-1
1
23
1
2
3
4
SH-1L-1
WC-1
WC-1L-1
SH-1
SK-1
SK-1
4
5
6
7
RB-1
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:0
9 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
P-201.1D
PLUMBINGRENOVATION FIRST
FLOOR AREA D
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1
PLUMBING RENOVATION FIRSTFLOOR AREA D
GENERAL NOTESPLUMBING ITEMS SHOWN LIGHT ARE EXISTING TO REMAIN.ITEMS SHOWN BOLD ARE TO BE REMOVED.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO WORK.
COORDINATE DOWNTIME OF SYSTEMS WITH OWNER PRIORTO WORK.
A.
B.
C.
KEYED NOTES - P-201.1D1 REWORK EXISTING WASTE AND VENT PIPING
TO CONNECT TO NEW WATER CLOSET WITHBACK OUTLET. CONNECT 1 1/4" DCW TOEXISTING DCW IN WALL. 4" WASTE TRHU WALLAND DOWN TO EXISTING SANITARY LINE.
2 PROVIDE NEW LAVATORY WITH WALLMOUNTED SENSOR FAUCET. CONNECT 1/2"DCW AND DHW TO EXISTING DCW AND DHW.CONNECT TO EXISTING WASTE AND VENT INWALL.
3 PROVIDE 1/2" DCW AND 1/2" DHW TO NEWSHOWER. 2" WASTE WITH P-TRAP FROM FLOORDRAIN AND CONNECT TO EXISTING SANITARYBELOW SLAB.
4 PROVIDE NEW HAND SINK AND CONNECT TOEXISTING DCW, DHW AND SANITARY.
5 PROVIDE NEW NOURISHMENT STATION SINKAND CONNECT TO EXISTING DCW, DHW ANDSANITARY. PROVIDE NEW 3/4" DCW TO ICEMACHINE WITH IN-LINE 5 MICRON FILTER ANDROUTE FULL SIZED DRAIN LINE FROM ICEMACHINE TO HUB DRAIN BELOW CABINETRY.CONNECT 2" WASTE FROM HUB DRAIN TOEXISTING SANITARY AND VENT LINES IN WALL.
6 EXISTING SANITARY AND VENT STACK TOREMAIN, PROVIDE NEW CLEANOUT ONEXISTING STACK. PROVIDE WALL ACCESSPANEL TO ACCESS CLEANOUT. FIELD VERIFYEXACT LOCATION OF STACK.
7 PROVIDE NEW HAND SINK AND CONNECT TOEXISTING DCW, DHW AND SANITARY.
No. Description Date
09/16/2016
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
67137
09/16/2016
RE
F.
PATIENT ROOM2-B80
2-OSOA 2-EL6OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
GROUP ROOM2-B51
WORK LOUNGE2-B52
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
PATIENT ROOM2-B78
PATIENT ROOM2-B76
PATIENT ROOM2-B75
COMMON AREA2-H1
SECLUSION ROOM2-B54
OFFICE2-B56
2-B74RESTROOM
PATIENT ROOM2-B73
2-OSOOD
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
RESTROOM2-B67
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
RESTROOM2-B77
RESTROOM2-B81
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
1
2
3
11
1
2
22
3
33
WC-1
L-1
SH-1
WC-1
L-1
SH-1
SH-1 SH-1
L-1
WC-1WC-1
L-1
NS-1
12
3
SH-1
WC-1
L-1
1WC-1
2
3
SH-1
L-1
1
2
3 SH-1
WC-1L-1
4
5SK-1
5
SK-1
6
7
RB-1
8WB-1
WCO
WCO
WCO
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:1
1 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
P-202.2B
PLUMBINGRENOVATION
SECOND FLOORAREA B
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1
PLUMBING RENOVATION SECONDFLOOR AREA B
GENERAL NOTESPLUMBING ITEMS SHOWN LIGHT ARE EXISTING TO REMAIN.ITEMS SHOWN BOLD ARE TO BE REMOVED.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO WORK.
COORDINATE DOWNTIME OF SYSTEMS WITH OWNER PRIORTO WORK.
A.
B.
C.
KEYED NOTES - P-202.2B1 REWORK EXISTING WASTE AND VENT PIPING
TO CONNECT TO NEW WATER CLOSET WITHBACK OUTLET. CONNECT 1 1/4" DCW TOEXISTING DCW IN WALL. 4" WASTE TRHU WALLAND DOWN TO EXISTING SANITARY LINE.
2 PROVIDE NEW LAVATORY WITH WALLMOUNTED SENSOR FAUCET. CONNECT 1/2"DCW AND DHW TO EXISTING DCW AND DHW.CONNECT TO EXISTING WASTE AND VENT INWALL.
3 PROVIDE 1/2" DCW AND 1/2" DHW TO NEWSHOWER. 2" WASTE WITH P-TRAP FROM FLOORDRAIN AND CONNECT TO EXISTING SANITARYBELOW SLAB.
4 PROVIDE NEW NOURISHMENT STATION SINKAND CONNECT TO EXISTING DCW, DHW ANDSANITARY. PROVIDE NEW 3/4" DCW TO ICEMACHINE WITH IN-LINE 5 MICRON FILTER ANDROUTE FULL SIZED DRAIN LINE FROM ICEMACHINE TO HUB DRAIN BELOW CABINETRY.CONNECT 2" WASTE FROM HUB DRAIN TOEXISTING SANITARY AND VENT LINES IN WALL.
5 PROVIDE NEW HAND SINK AND CONNECT TOEXISTING DCW, DHW AND SANITARY.
6 EXISTING SANITARY AND VENT STACK TOREMAIN. PROVIDE NEW CLEANOUT ONEXISTING SANITARY STACK. PROVIDE WALLACCESS PANEL TO ACCESS CLEANOUT. FIELDVERIFY EXACT LOCATION OF STACK.
7 3/4" DCW DOWN TO NEW ROUGH-IN BOXBEHIND REFRIGERATOR.
8 PROVIDE NEW WALL BOX (WB-1) AND CONNECTTO EXISTING DCW/DHW AND SANITARY WASTEAND VENT.
No. Description Date
09/16/2016
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
67137
09/16/2016
INSTALL SPRINKLER HEADS IN EXACT CENTER OF LAY-IN CEILING TILES THIS DETAIL APPLIES IN ALLLOCATIONS WHERE SPRINKLER HEADS ARE LOCATED IN SUSPENDED CEILINGS.
18" MIN
NOTE:
SPRINKLER HEAD
REDUCER
CEILING
SPRINKLER CROSS-MAINHYDRAULICALLY SIZED SLOPEBRANCHES 1/4" IN 10 FT. &1/8" IN 10' FOR MAINS
1"
CONT. THREADED RODANCHORED TO STRUCT.
1. WHERE PIPING IS EXPOSED TO VIEW PROVIDE WITH ESCUTCHEON.
NOTES:
PIP
EIN
SU
LA
TE
DP
IPE
UN
INS
ULA
TE
D
WALL RE: ARCH
PIPE
GALVANIZED STEEL PIPESLEEVE FLUSH WITH WALLPACK WITH FIBROUS
MATERIAL-ALL AROUND
INSULATION (WHERE SPECIFIED)
SEAL BOTH SIDESWITH ACOUSTICALSEALANT
FIRST LEVEL
ROOF LEVEL
A
SAN
2"
2"
SK-1
3/4"
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:1
1 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
P-800
PLUMBING DETAILS
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
NO SCALE1
SPRINKLER HEAD IN CEILINGDETAIL
NO SCALE2
PIPE PENETRATION THRUNON-RATED WALL DETAIL
No. Description Date
NOSCALE3BREAK ROOM SINK RISER
09/16/2016
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
67137
09/16/2016
1-D00OFFICE1-D01
OFFICE1-D02
OFFICE1-D03
OFFICE1-D04
OFFICE1-D05
CLASSROOM1-D06
COMPUTER ROOM1-D07
GAME ROOM1-D11
MULTI-PURPOSE
1-D12
LAUNDRY ROOM1-D13
SECLUSION1-D14
GROUP ROOM1-D15
PATIENT ROOM1-D18
PATIENT ROOM1-D19
PATIENT ROOM1-D20
PATIENT ROOM1-D21
RESTROOM1-D23
ADARESTROOM
1-D24
ADARESTROOM
1-D25
RESTROOM1-D26
PATIENT ROOM1-D28
PATIENT ROOM1-D29
PATIENT ROOM1-D30
PATIENT ROOM1-D31
PATIENT ROOM1-D33
PATIENT ROOM1-D34
PATIENT ROOM1-D35
MEDICINE ROOM1-D36CHART ROOM
1-D37
1-D40
Room
1-D42
1-D44
1-D46
1-D48
1-D50
1-H06
STAIR1-0S0F
RESTROOM1-D35A
RESTROOM1-D32
COMMON AREA1-H07
�
�
� �
�
� �
� �
��
�
� �
1
2
11111
1
1
11
1 1
1 1
2
2
2
22
1 1 2
1
1
1
1
3
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:0
5 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
FP-101.1D
FIRE PROTECTIONFIRST FLOOR AREA D
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1
FIRE PROTECTION FIRST FLOORAREA D
KEYED NOTES - FP-101.1D1 REPLACE EXISTING WET AUTOMATIC
SPRINKLER HEADS WITH PENDANT TYPE,QUICK RESPONSE SPRINKLER HEADS,INSTITUTIONAL TYPE, FOR LIGHT HAZARDOCCUPANCE AS OUTLINED IN NFPA 13 AND THESPECIFICATIONS.
2 REPLACE EXISTING WET AUTOMATICSPRINKLER HEADS WITH CONCEALED TYPEQUICK RESPONSE SPRINKLER HEADS, FORLIGHT HAZARD OCCUPANCY AS OUTLINED INNFPA 13 AND THE SPECIFICATIONS.
3 HATCHED AREA IS OUTSIDE OF THE SCOPE OFWORK.
GENERAL NOTESTHE FLOOR IS CURRENTLY ENTIRELY PROTECTED BY A WETAUTOMATIC SPRINKLER SYSTEM. WHERE NEW SPRINKLER WORK ISINDICATED, THE EXISTING SPRINKLER HEADS SHALL BE REMOVED ANDREPLACED WITH NEW SPRINKLER HEADS AS NOTED. REWORKEXISTING SPRINKLER HEADS TO MATCH NEW ARCHITECTURAL LAYOUT,REFER TO ARCHITECTURE REFLECTED CEILING PLAN.
REFER TO THE SPECIFICATIONS FOR SPRINKLER HEAD ORIFICE SIZES,TEMPERATURE RATING, FINISH ETC.
IN AREAS WITHOUT CEILINGS, WHERE DUCTWORK IS OVER 48" WIDE,PROVIDE HEADS BOTH ABOVE AND BELOW DUCTWORK.
FOR PROTECTION DURING CONSTRUCTION, TURN EXISTING FIRESPRINKLER HEADS UP WHEN CEILINGS ARE REMOVED AND REPLACEEXISTING SPRINKLER HEADS WITH NEW UPRIGHT PENDANT FAST-RESPONSE SPRINKLER HEADS. TURN EXISTING FIRE SPRINKLER HEADDROPS BACK DOWN FOR FINAL INSTALLATION WHEN NEW CEILINGSARE INSTALLED AND REPLACE PENDANT SPRINKLER HEADS WITH NEWCONCEALED FAST-RESPONSE SPRINKLER HEADS IN COMMON AREASAND NEW SECURITY TYPE FAST-RESPONSE SPRINKLER HEADS INPATIENT ROOMS AND OTHER SECURE AREAS AS NOTED ONDRAWINGS.
A.
B.
C.
D.
No. Description Date
09/16/2016
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
67137
09/16/2016
PATIENT ROOM2-B73
PATIENT ROOM2-B72
PATIENT ROOM2-B71
PATIENT ROOM2-B70
PATIENT ROOM2-B63
PATIENT ROOM2-B62
PATIENT ROOM2-B61
PATIENT ROOM2-B60
SECLUSION ROOM2-B54
OFFICE2-B56
PATIENT ROOM2-B75
PATIENT ROOM2-B76
PATIENT ROOM2-B78
PATIENT ROOM2-B80
OFFICE2-B50
OFFICE2-B48
OFFICE2-B46
OFFICE2-B44
OFFICE2-B45
OFFICE2-B47
MECHANICAL ROOM2-B49
RESTROOM2-B77
MEDICINE ROOM2-B53
LAUNDRY ROOM2-B55
STORAGE2-B57
GROUP ROOM2-B51
WORK LOUNGE2-B52
RESTROOM2-B67
RESTROOM2-B65
ADA RESTROOM2-B66
ADA RESTROOM2-B68
� �
� �
� �
��
2
1
2 2
2
11111
1
1
1
1
1
1
1
2
1 1
1 1
1
2
2
1
1
1
2
2
2
2
2
2
2
2
2
3
3
NORTHNORTH
0'
TAS
E OF TEXA
S
P RE
ENI
GNELANOISS
FO
R
EL I C E N S E D
T
JEFFERY N. BOLANDER
67137
Tx. Registration # F-2113
1/8" = 1'-0"
8' 16'
True Plan
TRUENORTH
PLANNORTH
KEY PLAN
11 Greenway Plaza, 22nd FloorHouston, TX 77046
713-965-0608 P713-961-4571 F
Texas Registered Engineering Firm: F-3709
MEP:
Shah Smith& ASSOCIATES, INC2825 Willcrest, Suite #350Houston, Texas 77046713-780-7563 P713-780-9209Texas Registered Engineering Firm: F-2113
In Association with:
CHECKED BY
REVISIONS
DRAWN BY
DATE
PROJECT NUMBER
CLIENT
www.pbk.com
9/1
6/2
01
5 4
:25:0
6 P
MC
:\U
se
rs\s
erv
er\
Do
cu
men
ts\1
042
-007
-04
_P
lbg
_R
15
_ch
olo
bau
gh.r
vt
HA
RR
IS C
OU
NT
YP
SY
CH
IAT
RIC
CE
NT
ER
UN
IT1D
AN
D U
NIT
2B
RE
NO
VA
TI O
NS
FP-102.2B
FIRE PROTECTIONSECOND FLOOR
AREA B
CMH
CJH
SEPTEMBER 16, 2015
14265
ISSUE FOR CONSTRUCTION
1/8" = 1'-0"1
FIRE PROTECTION SECONDFLOOR AREA B
KEYED NOTES - FP-102.2B1 REPLACE EXISTING WET AUTOMATIC
SPRINKLER HEADS WITH PENDANT TYPE,QUICK RESPONSE SPRINKLER HEADS,INSTITUTIONAL TYPE, FOR LIGHT HAZARDOCCUPANCE AS OUTLINED IN NFPA 13 AND THESPECIFICATIONS.
2 REPLACE EXISTING WET AUTOMATICSPRINKLER HEADS WITH CONCEALED TYPEQUICK RESPONSE SPRINKLER HEADS, FORLIGHT HAZARD OCCUPANCY AS OUTLINED INNFPA 13 AND THE SPECIFICATIONS.
3 HATCHED AREA IS OUTSIDE OF THE SCOPE OFWORK.
GENERAL NOTESTHE FLOOR IS CURRENTLY ENTIRELY PROTECTED BY A WETAUTOMATIC SPRINKLER SYSTEM. WHERE NEW SPRINKLER WORK ISINDICATED, THE EXISTING SPRINKLER HEADS SHALL BE REMOVED ANDREPLACED WITH NEW SPRINKLER HEADS AS NOTED. REWORKEXISTING SPRINKLER HEADS TO MATCH NEW ARCHITECTURAL LAYOUT,REFER TO ARCHITECTURE REFLECTED CEILING PLAN.
REFER TO THE SPECIFICATIONS FOR SPRINKLER HEAD ORIFICE SIZES,TEMPERATURE RATING, FINISH ETC.
IN AREAS WITHOUT CEILINGS, WHERE DUCTWORK IS OVER 48" WIDE,PROVIDE HEADS BOTH ABOVE AND BELOW DUCTWORK.
FOR PROTECTION DURING CONSTRUCTION, TURN EXISTING FIRESPRINKLER HEADS UP WHEN CEILINGS ARE REMOVED AND REPLACEEXISTING SPRINKLER HEADS WITH NEW UPRIGHT PENDANT FAST-RESPONSE SPRINKLER HEADS. TURN EXISTING FIRE SPRINKLER HEADDROPS BACK DOWN FOR FINAL INSTALLATION WHEN NEW CEILINGSARE INSTALLED AND REPLACE PENDANT SPRINKLER HEADS WITH NEWCONCEALED FAST-RESPONSE SPRINKLER HEADS IN COMMON AREASAND NEW SECURITY TYPE FAST-RESPONSE SPRINKLER HEADS INPATIENT ROOMS AND OTHER SECURE AREAS AS NOTED ONDRAWINGS.
A.
B.
C.
D.