21. SPECIFICATIONS
MODEL DSB-F074LHITEM
Function Cooling & Heating
Class T1
Power AC 220~240V/ 50Hz
Capacity W 2,050
Btu/h 7,000
Dehumidification l/h 1.0
Running Current A 3.1/3.3
Power Input W 680/720
Type Rotary
Model G4C072JU1ER (Samsung)Capacitor 30F / 450VAC
Division Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan
Capacitor 1.0F 400VAC 1.8F 400VAC
Motor Model Number YDK-8-4B YDK-30-68
Sound Level (Hi) dB(A) 39 48Fan Speed (Hi) RPM 1,350 850
Control Capillary
Charge Q'ty g 730
Type Flare
OD (Liquid/Gas) in(mm) 1/4 (6.35) 3/8 (9.52)Dimensions (W x H x D) mm 750 x 245 x 179 654 x 549 x 256Net Weight kg 7.0 34
Electrical Data
Compressor
FanMotor
Refrigerant(R-410A)
Connection
32. OUTLINE AND DIMENSIONS
1 INDOOR UNIT
750
Plate Mounting
REM
OCO
N
Connecting Pipe
Grille Insert
179
245
REM
OTE CO
NTROLLER
Frame G
rilleBody
Plate Mounting
DSB-F074LH
12
Indoor Unit
DSB-183LH/183LH-R/240LH-R, DSA-183LH-R/240LH-R
DSB-182LH
DSB-123LH/093LH
DSB-070LH/071LH/091LH/092LH
Indoor Unit
Indoor Unit
Indoor Unit
Installation Plate
Wall Hole (65)
Wall Hole (65)
Wall Hole (65)
Wall Hole (65)
Installation Plate
Installation Plate
Installation Plate
90
40
97
53
184
50 325 235 140
35
355 285 122
40
121 385 385 121
40
4017
80 460 400 140
50
INSTALLING THE INSTALLATION PLATE
Unit : mm DSB-F184, 244 LH/PH/AH
DSB-F154LH/PH/AH
DSB-F094, 124 LH/PH/AH
INSTALLING THE INSTALLATION PLATE. DSB-F074LH
5DSB-F074LH
Outlet
Foot Cushion
Cabinet Front
Cabinet SideP
anel TopGuide Support
SVC Cover
Servise Valve
Inlet
Outlet
Inlet
2 OUTDOOR UNIT
DSB-F074LH
6
1 NAME AND FUNCTION OF PARTS
Indoor Unit
3. OPERATION
Fan Direction(Up/Down)
Connection CoverRemove cover to accessthe AC connection fromthis unit to the outdoor unit.
Sensor Wire
02 Hose Cover (AH Model Only)
Electrostatic FilterRemoves dust particles from the air.
IndicatorsIndicate the setting
Indoor Cover
Power Plug
RemoteSensor
LCD Remote Controller
Deodorizing FilterRemoves bad smellsfrom the air.
Cold Air
Air In
Nano Silver FiltersRemoves dust and
prohibits germs.
Electric Dust Collector(Air clean Plasma)Removes small dust andgenerates (-) ions.(PH/AH Model Only)
7DSB-F074LH
Connection CoverRemove cover to access the AC connectionto the indoor unit.
Service ValvesThe indoor and outdoor unitsare connected by copper tubeswhich are connected here.
AIR IN
AIR OUT
Connection WireO2 Hose Wire(AH Models Only)
Connection Pipes
Drain Hose
Outdoor Unit
8Name of Each Button
2 REMOTE CONTROLLER
DSB-F074LH
MODE
SLEEP
ON/OFF
TIMER
ENTER/ CANCEL
FAN SPEED
TURBO/MILD
DisplayDisplay information
TIMER ENTER/CANCEL ButtonPress to enter a timer setting or to cancel timer setting
TIMER ON/OFF ButtonPress to set the unit off or on time.(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)
MODE ButtonPress to cycle through the modes(Auto/Quick/Cool/Fan/Dehumidifier/Heat)SLEEP ButtonPress to set the unit for the sleep mode.
FAN DIR. ButtonPress to select up/downdirection for fan.
ON/OFF ButtonPress to turn the uniton or off.TEMPERATURE ButtonsPress to raise or lower the desired temperature.
FAN SPEED ButtonPress to select the fan speed (High " ", Middle " ", Low " ", Natural).
COVERSlide down to access mostof the remote buttons.Slide down further toaccess the batterycompartment.
AUTO
FAN DIR.
TURBO/MILDPress to select super poweroperation (Turbo) mode.
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)Light to indicate the mode selected.
TIMER Indicators (Include sleep)Light to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicatorsLight to indicate the temperature or time.
FAN DIRECTION IndicatorsLight to indicate thefan direction.
NATURAL IndicatorLight to indicate thespeeds simulating a breeze.
FAN IndicatorsLight to indicate the fan speed.
AUTO
9If you set time in OFF-Timer Mode, the unit will stop at the set time.
If you set time in ON-Timer Mode, the unit will run at the set time.
(1) Range of setting temperature: 18~32C(2) Setting temperature: Operating temperature of compressor
(3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of roomtemperature.
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep " or "beep,beep".(1) In the case of receiving ON/OFF signal-"beep" "beep"(2) And so on-"beep"
OFF-Timer
3 DESCRIPTION OF FUNCTIONS
Unit ON
Unit OFF
SET Time HOUR
ON
OFF
ON-Timer
Unit ON
Unit OFF
SET Time HOUR
ON
OFF
Control of Room Temperature
Buzzer
COMP (ON)
*RT: ROOM TEMPERATURE DT: DESIRED TEMPERATURE
COMP (OFF)
-1C 0C(COOLING)
(RT-DT)
COMP (OFF)
COMP (ON)
-1C 0CHEATING
(RT-DT)+1C +1C
10
Fan Speed (Indoor Unit)
(1) Motor speed (high speed, middle speed, low speed).(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)(3) Relation of operating mode between fan speed.
(4) Automatic OperationIf the unit is set in 'AUTO' mode, the unit operates automatically according to the room temperature to keep theroom temperature comfortable.
0C
L
M
H
1C 2C (R.T-D.T)
0C
L
M
H
1C 2C (DT-RT)
(COOLING)
(HEATING)
FAN ONLY COOL DEHUMI- AUTO QUICK HEATDIFICATION
H H H L H H H
M M M L M H M
L L L L L H L
Auto X Auto L Auto H Auto
Natural Natural Natural L Natural H Natural
11
(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can beused to run the unit.
(2) The setting conditions of Emergency operation are as follows. Operation mode: Quick Preset temperature:18C: Cooling, 32C: Heating) Fan speed: High* You cannot operate with remote controller.
(1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature. (The unit will not operate after 4 hour)
(2) For changing the temperature.
(3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEPindicator will disappear in the display.
Sleep Mode
Indoor Fan Motor RPM for each Models
Emergency Operation
0 0.5 1.0 HOUR(COOLING CYCLE)
DT
+0.5C+0.5C
+0.5C
0 0.5 1.0 HOUR(HEATING CYCLE)
DT
0.5C0.5C
0.5C
MODEL
F074
F094
F124
F154
F184
F244
MODECOOLHEATCOOLHEATCOOLHEATCOOLHEATCOOLHEATCOOLHEAT
Turbo1360
1280
1290
1390
1280
1280
High135012301250112012601300138013501260115012601260
Mid129011201150102011501220132012601170105011701170
Low106010609909709701070102010901020100010201020
Ultra low910820840800840910940910900870900900
Monitoring
500
500
500
500
500
500
12
Frost Prevention of Indoor Unit
When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coiltemperature is lower than 0C at the end of 10 minutes of continuous compressor operation from the start, themicrocomputer of the unit stops the compressor to protect the unit from the frost. The control procedure forindoor coil freeze protection.
1) The compressor and outdoor fan turn off.2) Indoor fan operates according to user set speed.3) The normal operation returns when the indoor coil
temperature is higher than 7C or equal to 7C.
-1C +7C
Compressor and Outdoor Fan ON ON
OFF
Indoor FanSet speed
(Indoor coil temperature)
Auto Mode(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selectingoperating Mode according to the room temperature
(2) Selecting Operating Mode AgainRoom temperature meets desired temperature and the compressor stops running over 30 minutes, then the unitselects operating Mode again.
3 min. Time Delay of Compressor
In normal operation, there is a time delay of three minutes between turn off and turning back on including initialpower up.
ROOM TEMPERATURE
DT-2C RT
DT-2C RT DT+3CDT+3C RT
OPERATING MODE
Heating
Dehumidifier
Cooling
FLAP POSITION
Heating Position
Cooling Position
Cooling Position
(RT: Room temperature)
>
13
1) Cooling Mode* When the room temperature is higher than 22C1Fan Speed: Super high speed2Air discharge direction: Fixed3Set temperature: 18C (Fixed)4Compressor and Outdoor Fan
The air discharge direction procedure is belowFixed Up/Down Up/Down Fixed
* The option is LEFT/RIGHT direction.
1) Heating Mode* When the room temperature is higher than 22C1Fan Speed: Super high speed2Air discharge direction: Fixed3Set temperature: 18C (Fixed)4Compressor and Outdoor Fan
The air discharge direction procedure is belowFixed Up/Down Up/Down Fixed
* The option is LEFT/RIGHT direction.
Dehumidification Mode
Air Discharge Direction(only remocon operation)
Quick Mode(Powerful Cooling & Heating)
The air discharge direction procedure is below. Fixed Up/Down Fixed
Up/Down
1Desired temperature < Room temperatureOutdoor Fan, Compressor : ONIndoor Fan : Low speed
2Desired temperature Room temperatureCompressor : 3 min/ON, 5 min/OFFFan Speed : low speed
3Room temperature 18CCompressor : OFFFan speed : Low speed
COOLING POSITION
HEATING POSITION
14
Defrost Function Chart for Outdoor Condenser
Max Load Heating Operation Diagram
Note1 : 120sec for 24kBtu Model Note2 : The Temperature is over 120C or 15 minute later.
Note1 : 30s ON. 120s OFF when the Compressor is OFF. Note2 : The Fan is ON when the temperature is below 49C. Note3 : The Temperature is over 60C and 1 minute later.
Comp
Start
4 Way
OD Fan
ID Fan40sec*Note1
15min*Note2
6sec 6sec40sec
Return
60C
Temperature (Indoor Evaporator)
57C
49C
38C
ID FAN* Note1
Monitoring"Ultra Low"
Set Value"Hi, Mid, Low" "Hi" "Hi"
OD FAN OFF *Note2
OFF *Note3COMP
15
Self-Diagnostic Function
The control will contain diagnostic test to verify the integrity of the system.
(1)Error Code Display Pattern1ON LAMP: Blink
Self Diagnostic Function Description
1. Sensor ErrorOpen or Short circuit of Sensors, Room, Indoor Coil Sensor and Outdoor Coil SensorOpen : Micom, Input Voltage 0~0.3V, Short: Micom, Input Voltage 4.7~5.0V
2. Compressor ErrorAt the start operation, the Compressor is ON and 5 Minutes later, the Temperature change value of IndoorCoil is below +/-2C. Emergency Mode Operation detect only
3. 4 Way Valve ErrorAt the start operation, the Compressor is ON and then.Indoor Coil Temperature goes up to 2C in Cooling Operation ModeIndoor Coil Temperature goes down to 2C in Heation Operation Mode
LED BLINK PATTERN CASE NOTE
Room Sensor open or Short Continuously woorking to fix room temperature 18C in cooling mode.
Continuously woorking to fix roomtemperature 32C in heating mode
I/D coil sensor open or short Do not woorking
1 times blink O/D coil sensor open or short
Compressor or electrical parts Continuously workiugof compressor error.
2 times blink Gas leak
0.5s
8s
40
4. WIRING DIAGRAM
Indoor Unit
Indoor Unit
DSB-F094, 124LH DSB-F094, 124PH
43
Outdoor Unit
Outdoor Unit DSB-F074LH
DSB-F094, 124AH DSB-F154, 184 LH/PH
DSB-F154, 184AH DSB-F244LH/PH
5. REFRIGERANT CYCLE
18
Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.
[Heat Pump Mode]
19
2 Table of Suction Pressures according to thechange of Outdoor Room Temp.
MODEL
DSB-F074 LH/AH
DSB-F094LH/PH/AH
DSB-F124LH/PH/AH
DSB-F154LH/PH/AH
DSB-F184LH/PH/AH
DSB-F244LH/PH/AH
REFRIGERANT
730g
900g
1,000g
1,150g
1,200g
1,750g
INDOOR ROOMTEMP.(DB/WB, C)
27.0/19.0
27.0/19.0
27.0/19.0
27.0/19.0
27.0/19.0
27.0/19.0
OUTDOOR ROOMTEMP.(DB/WB, C)
25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 / 25.0 / 30.0 / 35.0 / 40.0 / 45.0 /
Bar (gage)8.38.79.19.29.78.58.99.39.49.97.68.08.48.69.08.08.48.89.09.47.68.08.48.69.07.68.08.48.69.0
kPa, (gage)830870912925970850890932945990760800843860900800840883900940760800840860900760800840860900
SUCTION PRESSURE
NOTE)1) These experiments are processed on the condition of the fixed indoor room TEMP.( DB: 27.0C, WB: 19.0C)2) It takes at least ten minutes for the change of suction pressure to be steady-state, after Air conditioner operates3) To analyze accurately whether refrigerant of Air conditioner leaks or not, you have to check not only suction
pressure but also discharge and suction temperature of compressor4) These data can be changed slightly according to the temperature of environment or each set(Air conditioner)
20
3 R410A & R22 SATURATION PRESSURE TABLER410A R22
Temp (C) PRESSURE(LIQUID): bar PRESSURE(VAPOR): bar PRESSURE: bar0 7.991 7.967 4.981 8.248 8.223 5.1442 8.511 8.486 5.3123 8.781 8.754 5.4844 9.057 9.029 5.6615 9.339 9.311 5.8416 9.628 9.599 6.0267 9.924 9.894 6.2158 10.23 10.2 6.4099 10.54 10.5 6.607
10 10.85 10.82 6.80911 11.18 11.14 7.01712 11.51 11.47 7.22913 11.85 11.81 7.44514 12.19 12.15 7.66715 12.54 12.51 7.89316 12.9 12.87 8.12417 13.27 13.23 8.36118 13.65 13.61 8.60219 14.03 13.99 8.84820 14.43 14.38 9.121 14.83 14.78 9.35722 15.24 15.19 9.61923 15.65 15.61 9.88724 16.08 16.03 10.1625 16.52 16.47 10.4426 16.96 16.91 10.7227 17.41 17.36 11.0128 17.87 17.82 11.3129 18.34 18.29 11.6130 18.83 18.77 11.9231 19.31 19.26 12.2332 19.81 19.76 12.5533 20.32 20.26 12.8834 20.84 20.78 13.2135 21.37 21.31 13.5536 21.91 21.85 13.8937 22.46 22.4 14.2438 23.02 22.95 14.639 23.59 23.52 14.9740 24.17 24.1 15.3441 24.76 24.69 15.7142 25.37 25.3 16.143 25.98 25.91 16.4944 26.61 26.53 16.8945 27.24 27.17 17.2946 27.89 27.82 17.747 28.55 28.48 18.1248 29.23 29.15 18.5549 29.91 29.84 18.9950 30.61 30.53 19.4351 31.32 31.24 19.8852 32.04 31.97 20.3353 32.78 32.7 20.854 33.53 33.45 21.2755 34.29 34.22 21.7556 35.07 35 22.2457 35.86 35.79 22.7458 36.67 36.59 23.2459 37.49 37.42 23.7560 38.33 38.25 24.27
Relay RL1
Indoor fanmotor
* : Heat Pump Model Only
Compressor
Relay RL2
* Outdoorfan motor
Relay RL3
* 4 way valve
TRIAC
DC12V
Operating Mode
Fan Speed
Timer Selection
Flap Position
Unit on lamp
Room air temp.
Indoor coil temp.
* Outdoor coiltemp
Air clean lamp
Quick lamp
Remote
Emergency
Operation
Signalreceiver
Timer lamp
A/D converter lnitialization
Clock generation
DC power supply
Circuit forrelay driving
Circuit forTRIAC control
SMPS
Circuit for signal receiver
MICROCONTROLLER
Beeper
circuit formotor driving
Steppingmotor
Temp. Setting
ON/OFF
SLEEP
REMOCON
AC220V50Hz
STEPPING MOTORON/OFF
COMPRESSORON/OFF
DC5V
21
6. CONTROL BLOCK DIAGRAM
DSB-F074LH
22
7. TROUBLE SHOOTING
Outdoor unit doesnot run?(note. 1)
Doesthe com
pressor runnorm
ally?
Indoor unit doesnot run(note 1)
Check the failurecode according tothe self diagnostic
(note 2)
Is the unit display
morm
al?
check the failure code according to
the self-diagonostic(note 2)
Normalcheck the connecting
point ofm
agneticcontactor
YES
YES
YES
YES
NO
NO
YES
Trouble
Is the powerapplied to the
unit
Is the power norm
al?check the voltage between
L & N of terminal
block
press the power ON/OFF button on rem
ote controller
Does the beeper beep two
times?
Is the displayall off?
Check the connector on displayPCB connected to control PCB Check the display PCB itself
Check power supply mainsor interconnection wires
Check the wiring of indoor
Is the switch position
on switch pannel at "Rem
ote"
Does control PCB
status LED repeat one second "on and
off"?
control PCB fault M
icom or reset
IC fault Check the remote signal receiver Check the connection between signal
receiver and control PCB
Place the switchposition to the
"Remote" and then
Check it once m
ore
YES
NO
YES
NO
NO
NO NO
YES
YES
YES
YES
YES
NO
NO
NO
Is theunit display
normal?
23
Note 1)1Neither indoor unit nor outdoor unit runs.
Check the following points first. (There are following case in normal operation)a. Is the timer mode set the "timer ON".b. Is the timer mode set the "timer-OFF" and the time had passed?
2Neither outdoor fan nor compressor runs while indoor fan runs.Check following points first. (There are following cases in normal operation)a. Is the temperature set point suitable?b. Has the 3 minutes time guard for compressor operated?
Error Code 1When the compressor do not run.
i) Check the voltage between and of terminal block.(Indoor Unit, Outdoor Unit)
ii) Check connecting wire of indoor unit and outdoor unit. iii)Check relay RL1 on power P.C.B
2Check fixing of indoor coil thermistor.3Check the GAS LEAKAGE of the pipe.
YL
Self-Diagnostic Function
24
Confirm following statement.When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.1Check the function select switch. Is it timer mode? 2The function select switch locate the sleep mode and is the setting time over?3 Is the setting mode DEHUMIDIFIER mode?4When the unit is DEHUMIDIFIER mode while in the auto mode, the outdoor unit and indoor unit does
not run.
The power is applied to the unit
Check the voltge between and of terminal blockY
LCheck the
Breaker or Fuse
Self Diagnosticfunction is ON
Check according toself Diagnostic function
Control P.C.B defect
Check the indoor unit displayis the display all off?
Press the ON/OFF switch ofRemote Control
Is the indoor unit display all off?
Pull out the power plugand then insert the power plug
after 5 second
Control P.C.B is normalRecheck from the beginning
Rating voltage more than 90%
Rating voltageunder 90%
No No
No
YesYes
Neither Indoor Unit nor Outdoor Unit Runs
25
Check rotation of indoor fan
Rotate indoor fan by hand
Check input Voltage of FanMotor connector at power P.C.B
Check the winding resistance of Indoor unit fan motor
Check the fan motor capacitor
Check the connecting wire of indoor fan motor
Run again
Check the starting of indoor fan motor
Run again
Check the Fan Motorbearing and fan
Check the power P.C.B.
The circuit for triac control
Change of fan motor
Normal
NO
Rating voltageunder 90%
Open or short
No
YES
Rating Voltage more than 90%
Normal
Outdoor Unit Runs but Indoor Fan does Not Run
26
Confirm following statement.When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.1 Is the setting temperature proper? 2 Is the unit during 3min. Time delay of compressor.3During frost prevention of lndoor unit.4During dehumidifier mode.
Outdoor Fan and Compressor Do Not Run
Check the voltge between and of indoor unit terminalY
L
Check the voltge between and of outdoor unit terminalY
L
Check compressor,outdoor fan motor individually
Check theconnecting wire
Check the wiringand voltagewithin doors
Rating voltageunder 90%
Rating voltage
under 90%
27
- Check the following at cooling mode
Check the voltge between and of indoor unit terminalY
L
Check the voltge between and of outdoor unit terminalY
L
Check the wiring of outdoor unit
Check the compressor(Check the winding resistance)
Check the compressor capacitor
Check the connectingwire between indoor
and outdoor.
Change the controlP.C.B
Change thecompressor.
Check the control P.C.Bthe circuit for relay
driving.
Rating voltageless than 90%
NG
Open or Short
Rating voltage
less than 90%
Rating voltage more than 90%
Rating voltage more than 90%
OK
Only Compressor does not Run
O2 Generator/Plasma Clean System Trouble Shooting
1. Both of the two system is switched by RL4 (on the POWER PCB) only.2. If some trouble occurs, check the RL4 and around its wiring.3. No problems in the PCB and Witing, check the Generator system or Plasma system.
RemoteOperation
RL4Turn ON
O2 GeneratorMotor O2 (AH Model Only)
High Volt (PH Model Only)High VoltGenerator
28
1 PCB CIRCUIT DIAGRAMDSB-F074LH
8. PCB DRIVING DESCRIPTION
29
DSB-F074LH PART LIST (INDOOR UNIT)
PART NAME SPEC QTY LOCATIONUSE 250V 50T 3.15A 1 FUSE
FUSE CLIP AFC-520 2 FUSEVARISTOR 15G561K 1 VAR
WAFER YW396-05AVD 1 CN2WAFER YW396-03AVD 1 CN1C-CERA 104Z,50VDC 5 CC1,2,5,6,7C-CERA 103Z,50VDC 6 CC3,4,9,10,11,12C-MULTI 104Z,CR0561B-Z5U 1 CC8C-ELEC 470uF 35V SD 1 CE1C-ELEC 10uF 450V SD 2 CE3,CE4C-ELEC 100uF 16V SD 1 CE2C-ELEC 10uF 16V SS 1 CE5C-ELEC 4.7uF 50V SS 1 CE6
C-ARRAY F3 104Z 1 CA3C-ARRAY F4 104Z 1 CA2C-ARRAY F5 104Z 1 CA1
RESISTOR 1/4W-12.7KF 3 R27,28,29RESISTOR 1/4W-1KJ 21 R5,12,13,14,15,16,17,18,19,20,
R21,23,30,31,32,33,34,35,36,37,43
RESISTOR 1/4W-10KJ 1 R11RESISTOR 1/4W-5.6KJ 1 R22RESISTOR 1/4W-330J 3 R24,25,26RESISTOR 1/4W-100J 2 R1,R4RESISTOR 1/4W-68KJ 2 R8,R9RESISTOR 1/4W-51KJ 1 R6RESISTOR 1/4W-2KJ 1 R7RESISTOR 1/2W-1KJ 1 R2 RESISTOR 1W-47J 1 R3RESISTOR 1/4W-3.24KF 1 R41RESISTOR 1/4W-49.9KF 1 R40RESISTOR 1/4W-32.4KF 1 R38RESISTOR 1/4W-24.9KF 2 R39,42
RESISTOR ARRAY 4A 103J 1 RA3RESISTOR ARRAY 5A 103J 1 RA2RESISTOR ARRAY 6A 103J 1 RA1
PIN GP881205-2(187) 1 CN4C-LINE ACROSS 275V 104K 2 CL1,CL2
WAFER YFW800-01D 1 CN3WAFER SMAW250-06(WHITE) 1 CN6WAFER SMAW250-08 1 CN5WAFER YMAW250-04 1 CN7WAFER YMAW250-02 1 CN8DIODE 1N4007 TAPE 1 D3
Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
30
PART NAME SPEC QTY LOCATIONDIODE UF203 1 D2
DIODE ZENOR 1N5241B 1 ZD1DIODE ST01D-200 1 D1
C-CERA 2200pF, 250V 1 CY1CHOKE COIL 1mH, 0.5A 1 L1FILTER EMI 0.6*10*3TURN 1 L2
BUZZER BM-20K 1 BZ1COIL 130uH, 3A 1 L3
IC REGULATOR KIA7805P 1 IC3TR KRC102M 1 TR1
IC RESET KIA7042P 1 IC5RELAY US11-12S 1 RL3RELAY UKH-12S 1 RL1
SW TRANS 264P,1916 1 TRS1CAPACITOR 1uF,400VAC 1 CAP1
PCB CONTROL 162.5X140X1.6T 1 PCBIC SWITCHING TNY264P 1 IC2DIODE BRIDGE S1NB80 1 BD1
TRIAC SM3JZ47 1 T1PHOTO COUPLER TLP560J 1 PT1
IC DRIVE TD62004AP 2 IC4,IC6RESONATOR CST8.00MGW 1 OSC
IC MICOM TMP87C846AN 1 IC1PHOTO COUPLER TLP421 2 PC1,PC2
MODELCOOL HIGH COOL LOW HEAT HIGH HEAT LOW MONITORING
R41 R39 R40 R38 R42
DSB-F074LH 3.24 24.9 49.9 32.4 24.9
MODELCOOL HIGH COOL LOW HEAT HIGH HEAT LOW MONITORING
R28 R30 R29 R31 R27
DSB-F154LH/PH 3.65 22.6 32.4 36.5 22.1
MODELCOOL HIGH COOL LOW HEAT HIGH HEAT LOW MONITORING
R33 R35 R34 R36 R37
DSB-F184LH/PH/AH 5.76 12.4 32.4 22.1 22.1
DSB-F244LH/PH/AH 5.76 12.4 5.76 12.4 22.1
85
R-OPT. DETAIL LIST
LED PCB ASS`Y No PART CODE PART NAME SPEC Q'TY UNIT REMARK
CC1 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EACN1 3108804800 WAFER SMAW250-08 1 EA
HOLD 3103002700 HOLDER LED ABS 1 EAL1 DDLS05031D LED DLSO-5031D(RED) 1 EAL2 DDLG05031D LED DLG-5031D(GRN) 1 EAL3 DDLS05031D LED DLSO-5031D(RED) 1 EAL4 DDLY05031D LED DLY-5031D(YLW) 1 EA
PCB 3104398201 PCB LED 110*31*1.6T.10(288) 1 EARCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EASW1 5S40202000 S/W PUSH JPS2281 1 EA
LED PCB ASS`Y (MODEL : F094/F124/F184/F244)No PART CODE PART NAME SPEC Q'TY UNIT REMARK
CC1 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EACN1 3108804800 WAFER SMAW250-08 1 EA
HOLD 3103004100 HOLDER LED 1 EAL1 DDLS05031D LED DLSO-5031D(RED) 1 EAL2 DDLG05031D LED DLG-5031D(GRN) 1 EAL3 DDLS05031D LED DLSO-5031D(RED) 1 EAL4 DDLY05031D LED DLY-5031D(YLW) 1 EA
PCB 3104398202 PCB LED 150*24.5*1.6T(240) 1 EARCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EASW1 5S40202000 S/W PUSH JPS2281 1 EA
LED PCB ASS`Y (MODEL : F154)No PART CODE PART NAME SPEC Q'TY UNIT REMARK
CC1 CXCH1H103M C CERA 103J/50 20% 1 EACN1 3108804600 WAFER SMAW250-07 1 EA
HOLD 3103001100 LED HOLDER ABS (BLK) 1 EAL1 DDSR302D-- LED DLSR-302D(RED) 1 EAL2 DDLG302D-- LED DLG-302D 1 EAL3 DDSR302D-- LED DLSR-302D(RED) 1 EAL4 DDLY302D-- LED DLY-302D 1 EA
PCB 3104395412 LED PCB 67.5*40*1.6T(350) 1 EARCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EA
SWITCH PCB ASS`Y (MODEL : F154)No PART CODE PART NAME SPEC Q'TY UNIT REMARK
CN1 3108804700 WAFER SMAW250-02 1 EAPCB 3104395311 S/W PCB 36*29.5*1.6T(891) 1 EASW1 5S30101330 SWITCH SLIDE KSA-2340B 1 EA
86
33
Power Supply(1)
DESCRIPTION
DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac DrivingPhoto Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified byBridge Diode, and it is filtering by Main Condensor CE1.Filtered DC voltage is about +18V, is regulated +12V DC by Regulator IC7812.And it is regulated +5V DC by Regulator IC7805.VAR is serge filter and CC1, CC2, CC3 is Noise filter.
AC 220V
CL1
275V104K
VAR
FUSE1
3.15A
POWER TRANS
D2CC1 CE1
D3
D1
D4104
+
35V1000F
IC27812
VI VO
G
IC37805VI VO
G+25V470F
CC2 CC3 CE3CE2
104+
16V100F
104
12V 5V
Oscillator(2)
19OSC
CC13104
5V
8M20
34
Room temperature and Evaporator temperature Sensor Input
DESCRIPTION
Number 24, 25 of Micom is Terminal of A/D convertor Input.Room temperature and Evaporator temperature is sensing by change of Thermister Resistance, Micom is putin 5V by ratio between R10 (12.7K) and R11 (12.7K).Relation between temperature and voltage is following Table 3-1.CC5, 6 is Noise filter.
Temperature(C) No. 1 No. 3-5 1.127 1.127
0 1.378 1.378
5 1.650 1.650
10 1.936 1.936
15 2.228 2.228
Voltage (V)
Table 3-1
Sensor(3)
070LH,091LH182LH, 240LH
O/C SENSOR
I/C SENSOR
ROOM SENSOR
CN10
330 R8
R7
R6
330
330CC5103
R912.7kF
CC7103
103CC6
23
24
25
MICOM
CN9
R1012.7KF
R1112.7KF
VDD-10%
VSS+10%Fig 2-1
DESCRIPTION
Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency.Ocillatory wave is as following Fig 2-1.
35
Triac Driving(4)
DESCRIPTION
Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is suppliedTrigger Signal.Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Timedelay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.
N
LAC 220V
TO MOTOR
T1SM3JZ47
L11 2
130H3A
SN10.1F120Ohm
TLP561PT1
12V
R5
1K1/2W
IC4KID 65004
MICOM
38 2 15
AC220V
TRIGGER
MOTORINPUT
LOW SPEED MEDIUM SPEED HIGH SPEED
Fig 4-1
LOW SPEED MEDIUM SPEED HIGH SPEED
36
DESCRIPTION
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gottenfid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.But in Secondary Wave Custom Code is Reversed Face.
LEADER CODECUSTOM
CODEDATACODE
CHECKSUM
TAILER
9ms 4.5ms 16bit 16bit24bit 8bit
Fig 5-1 Fig 5-2BIT STRUCTURE
Remote Controller(5)
0.56ms 0.56ms1.69ms
1.12ms 2.25msbit 0 bit 1
Selecting Mode(6)
(SELECT S/W INPUT, OUTPUT)
MICOM13
R141K
RA1
5V
CA1F4104Z
P2MODESELECTPUSH S/W
DESCRIPTION
There are Mode according to SW position asfollowing Table 6-1.According as port of fixed Micom is Low, the unit isoperating as following Table 6-1.
Table 6-1
POSITION MODE OPEN REMOCONGND EMERGENCY
37
DESCRIPTION
MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.
Micom Power Supply(7)
VDD 42CE5
10F16V
CC11104
CC13104
+
5V
414039
2221
19OSC8MHz
20
VSS
MICOM
38
DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detectPower ON and Voltage less than 4.25V, and then send Reset Signal.
Reset(8)
R13 5.6K
1K R1218
CC9
CE4
4.7uF/50V
IC57042P
10.3
MICOM
4.25V
H
L t
t
POWERON
Vcc (+5V)
DELAY TIMEFOR POWER ON
RESET
39
DESCRIPTION
Micom 34 Terminal put out Buzzer Driving Pulse,its output is driving Buzzer through Buffer.Ocillatory Frequency of buzzer is selected byinternal Micom.This unit is setting at 4KHz.
VCC12V
KID 65004
MICOM
34 6 11
R41K BZ1
Buzzer Driving(10)
DESCRIPTION
Selecting function is as following table 9-1.* When power source is put at fist, Funtion selection input is recognized.
And when the unit is running the microcomputer ignore variation of funtion selection input.
JS3
JS2
JS1
1K14
15
16
30
29
28
41
40
39
27
26
1K
1K
1K
1K JS5
JS41K
1K
1K
1K
1K
R28
R32
R31
R30
R25
R24
R23
R35
R34
R33
R37R29
1K
R17
MICOM
R16
R15
CA2
CA1F5 104Z
RA1 R36 heat/low
heat/high
cool/low
cool/high
monitoring
6A
RA3RA3
4A 103JCA3F3 104Z
103J
RA2
Function Selecting(9)
MODELSwing direction Turbo(heating) Flap angle Heating/Cooling Ultra low TEST Oxygen/Plasma
JS1 JS2 JS3 JS4 JS5 JS6 JS7DSB-F074LH X X X O O X ODSB-F094LH X X X O O X O
DSB-F094PH/AH X X X O O X XDSB-F124LH X X X O O X O
DSB-F124PH/AH X X X O O X X
MODELSwing direction Turbo(heating) Flap angle Heating/Cooling Ultra low TEST Oxygen/Plasma
JS1 JS2 JS3 JS4 JS5 JS6 J17DSB-F184LH X X X O O O
DSB-F184PH/AH X X X O O XDSB-F244LH X X X O O O
DSB-F244PH/AH X X X O O X
MODELSwing direction Turbo(heating) Flap angle Heating/Cooling Ultra low TEST Oxygen/Plasma
JS1 JS2 JS3 JS4 JS5 JS6 J21DSB-F154LH O X O O ODSB-F154PH O X O O X
40
DESCRIPTION
It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom. Detail Driving is as following Fig 11-1.R19 is Resistance to limit current.
MICOM
TRANSOUTPUT
D5
D6 R25.6K
12
CC4103
TR1KRC120M
1 2 1
23
2 1
R310K
R271K
VCC
31
DETECT POINT
H
TheNumber31 ofMicomterminal
AC18V
L
Fig 11-1
Zero Crossing Detect(11)
41
DESCRIPTION
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.It is driving as following Fig 12-1. (Ring Count Method of 8 Status)
4
3
2
1
B+
6
5
4
3
2
1
12V
IC6
KID65004
CN13
1
MICOM2
3
4
M1FOR SWING
4
3
2
1
Fig 12-1(Normal Rotating) (Reversed Rotating)
Stepping Motor Driving(12)
42
(1) U1 (MICOM)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
VDD
(XTOUT)P22(XTIN)P21
(INT5/STOP)P20P17
P16
(TC2)P15(PPG)P14(DVO)P13
(INT2/TC1)P12(INT1)P11(INTO)P10(AIN7)P67(AIN6)P66(AIN5)P65(AIN4)P64(AIN3)P63(AIN2)P62(AIN1)P61(AIN0)P60
VAREF
P77(HSO)P76(HSCK)P75(SO)P74(SI)P73(SCK)P72(PDO/PWM)P71(INT4)P70(INT3/TC3)P07
P06
P05
P04
P03
P02
P01
P00
TESTRESETXIN
XOUT(VASS)VSS
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
Steppping MotorDriving
Indoor Unit Motor Driving
Buzzer DrivingRemocon Input
Comp Relay DrivingZero Crosing Detect
Function S/W
TemperatureSensor Input
LED Driving
EmergencyMode
FunctionS/W
Reset Curcuit
Oscillation
2 KEY COMPONENTS OF ELECTRONIC CIRCUIT
43
(2) U2, 4 (KID65004) DARLINGTON ARRAYS
(3) U8 (KIA7805P) : VOLTAGE REGULATOR (5VDC)
(4) U7 (KIA7812P) : VOLTAGE REGULATOR (12VDC)
IN1 1 16 OUT 1IN2 2 15 OUT 2IN 3 3 14 OUT 3IN 4 4 13 OUT 4IN5 5 12 OUT 5IN6 6 11 OUT 6IN7 7 10 OUT 7
GND 8 9 COMMON FREE WHEELING DIODES
COMMON
10.5K7.2K
3K
OUTPUT
GND
INPUT
100K 500 100 100
0.3
10K
6K
500
1K 5K
28K
6K
30pF
2K
5K
200
240
1.4 K2.7
K
3.3 K
0.19K
INPUT
OUTPUT
GND
SCHEMATIC DIAGRAM
123
Fin 2 is groundfor Cose 221A.Case is groundfor Case 1.
10KINPUT
GND
10K
300
36K
64K
520
26K60K
29K20K
20K
40pF
50K
50 200
300
200
10016K
210
012
OUTPUT
(Top View)
Pin 1. INPUT2. GROUND 3. OUTPUT
Pin 1. INPUT2. GROUND 3. OUTPUT
(Equivalent Circuit)
KID65004AP
(Equivalent Ciircuit)
44
(5) U9 (KIA7042P) : RESET IC
KIA7042P
OUTLINEINPUTGROUNDOUTPUT
VCC1
3
2
OUT
GND
45
ERRORNo
ERRORNo
ERRORNo
No
No
NoYes
Select ON/OFF button
Select Mode button
Select FAN SPEED button
Select FAN DIR. button
Power Supply
TEST STARTPower supply again
Check the FollowingBATTERY SPRINGMICOMPCBLCD
Is Display at thebeginning ON?
Is Display at thebeginning ON?
Is it normal?
Is it normal?
Is it normal?
3 REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD
ERRORNo
ERRORNo
(Whenever you selectted Temp.Button, it is changed by 1C (18~32C)
( )
Select TEMP. Button (,)
Select ON/OFF button
Is display at thebegining ON?
Is it normal?
46
(0.5~24 HOUR)
ERRORNo
Select TIMER ON Button
Select Timer Enter Button
Select CANCEL Button
Select ON/OFF Button
Select OFF (Timer) Button
Select SLEEP Button
Select SLEEP Button
TEST OK!
Is LCD display OFF?
Is it normal
display?TIMER
Is all display OFF?
Is it normal?
SLEEP MODEDisplay ON?
Is display at thebeginning ON?
ERRORNo
ERRORNo
ERRORNo
ERRORNo
ERRORNo
ERRORNo
47
1 INDOOR UNIT
9. DISASSEMBLY INSTRUCTIONS
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cordfrom the wall outlet.
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)1Draw up the Insert Grille and remove it.2Loosen the screw fixed at the Cover Ter-Block.3Loosen two screws fixed at the Frame Grille.4Remove the Frame Grille.
3. Removing the Control Box. (Fig 3)1Remove room and coil thermistors.2Disconnect the fan motor lead wire from connection at the
Control PCB.3Disconnect the stepping motor lead wire from connection at the
Control PCB.4Remove the select switch from connection at the Control PCB.5Loosen the screw fixed at the ground wire.6Remove the Control Box
4. Removing the Drain Pan. (Fig 4)1Disconnect the Body drain hole. (left and right Body)2Disconnect three hooks and remove the Drain Pan.
5. Removing the Indoor Evaporator. (Fig 5~6)1Remove the screw fixed at the indoor Evaporator of the Body.2Remove the hook fixed at the Bracket Pipe of the back of Body.3Remove Indoor Evaporator.
6. Removing the Cross Flow Fan. (Fig 7)1Remove set screw fixed at the Motor shaft.2Remove Cross Flow Fan.
7. Remove Motor IDU and Bearing Plastic.
Fig 1
Fig 3
Fig 4
Fig 5
Fig 6
DSB-F074LH
Fig 2
Fig 7
48
2 OUTDOOR UNIT
DSB-F074LHPROCEDURES PHOTOS
1.Stop the operation of the air conditioner and disconnect the wire fromIndoor Unit to Outdoor Unit.
2. Disassemble the case. (Fig 1~2)1Remove the Top Panel. (Loosen thirteen screws)2Remove the Front Cabinet. (Loosen six screws)3Remove the Side Cabinet. (Loosen seven screws)4Remove the Guide Support. (Loosen two screws)
3. Removing the Propeller Fan. (Fig 3)1Loosen the Nut fixed at the the Propeller Fan.2Remove the Plain Washer.3Remove the Propeller Fan.
4. Removing the Motor ODU. (Fig 4)1Loosen four screws fixed at the Bracket Motor.2Disconnect the wire at the Control Panel and remove the Motor ODU.
5. Removing the Dual Capacitor. (Fig 5)1Disconnect the wire at the Control Panel.2Loosen the screw fixed at the Clamp Capacitor.3Remove the Dual Capacitor.
6. Removing the Over load Protector. (Fig 6~7)1Loosen the Hex Nut at Terminal Cover.2Remove the Terminal Cover.3Remove the wire at the Over load Protector.4Remove the Over load Protector.
Fig 5
Fig 4
Fig 6
Fig 7
Fig 1
Fig 3
Fig 2
49
3 EXPLODED DIAGRAM (Indoor Unit)DSB-F074LH
50
DSB-F074LH PART LIST (INDOOR UNIT)
No PART CODE PART NAME Q'TY SPEC REMARK1 3100400301 BODY 1 HIPS T2.02 3108008700 MOTOR IDU 1 YDK-8-4B3 3101500400 CUSHION MOTOR 2 CR 304 3106400400 BEARING PLASTIC Ass`y 15 3100053700 FAN CROSS FLOW Ass`y 1 90.0 x L5406 7485401012 SET SCREW 1 6S-4x10-E MFZN7 3103002601 HOLDER MOTOR 1 HIPS T2.08 3110050820 EVAPORATOR Ass`y 19 3102501220 GUIDE EVA. 1 PVC L536xT0.710 3100603800 BRACKET PIPE 1 HIPS T2.011 3108100801 PAN DRAIN 1 HIPS T2.012 3106001600 BLADE VERTICAL 3 P.P. T1.513 3108003900 MOTOR STEPPING 1 MP24GA , GSP-24SW-06114 3107600400 FLAP 1 HIPS T2.515 3101404800 COVER WIRE L 1 HIPS 16 3101404900 COVER WIRE R 1 HIPS17 3100054202 LED PCB Ass`y 118 3100901600 CAP RUBBER 1 SILICON19 3110051130 CONTROL BOX Ass`y 1
19-1 3100508400 CONTROL BOX 1 P.P. + G.F. 20%19-2 3114302030 CONTROL PCB Ass`y 119-3 3108912310 TERMINAL BLOCK 1 SN-DBW-05P19-4 3104896300 SENSOR ID Ass`y 1 PTM-KD-43C-D219-5 3101300100 POWER CORD Ass`y 1 16A 250V19-6 3101203000 CLAMP WIRE 1 P.P. + G.F. 20%19-7 3102797910 HARNESS 1 EARTH I/D19-8 3112704470 HARNESS AC SIGNAL 2 1 UL1015 WHITE(L6000)20 3100400410 BODY-TOP 1 HIPS T2.021 3102200800 FRAME GRILLE 1 HIPS T2.522 3104508700 PLATE LED 1 P.C. Sheet T2.023 3104510200 PLATE SWITCH 1 P.C. Sheet T2.024 3101404600 COVER TERMINAL BLOCK 1 HIPS T2.025 3101100400 CASE FILTER 2 P.P. T2.026 3101902510 FILTER CARBON Ass`y 1 Black27 3101902610 FILTER ELECTRO Ass`y 1 White28 3102200900 FILTER FRAME 2 P.P. T2.029 3112400820 INSERT GRILLE 1 HIPS T2.530 3115500500 COVER LED 1 ABS() T2.031 3104507200 PLATE MOUNTING 1 SBHG 1 T0.7
Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
51
DSB-F074LH
4 EXPLODED DIAGRAM (Outdoor Unit)
52
DSB-F074LH PART LIST(OUTDOOR UNIT)
No PART CODE PART NAME Q'TY SPEC REMARK
1 3100014730 PAN BASE ASSY 12 3116005510 BOLT COMP 3 M8 x L45.53 3102100800 FOOT 2 SECC T1.24 COMP. GROMMET 3 EPDM
3117143600 1 G4C072JU1ER DSB-F074LH5 COMPRESSOR ASSY
6 7400208411 COMP. WASHER 3 M8.4 x 22 xT1.67 7392801211 COMP. NUT 3 M8 x P1.25 MFZN8 311009JB00 CONDENSER ASSY 1 L465xW208.5xH5089 311009JC00 PIPE COND. IN 110 311009JD00 PIPE COND. OUT 111 3100602210 BRACKET SERVICE 1 SECC T1.212 3110051700 SERVICE VALVE 1 3/8"13 3110051810 SERVICE VALVE 1 1/4"14 7347602011 BOLT HEX 4 M6 x L20 MFZN
311009JM00 1 DSB-F074LH15 PIPE REVERSING ASSY
16 3115404800 CHECK VALVE 1 12.73114476300 1 O.D3.2xI.D1.4xL5003114474400 PIPE CAPILLARY COOL 1 O.D3.2xI.D1.4xL700
173114476600 1 O.D3.2xI.D1.6xL10003114476400 1 O.D3.2xI.D1.4xL7003114474500 PIPE CAPILLARY HEAT 1 O.D3.2xI.D1.4xL7003114476700 1 O.D3.2xI.D1.6xL700
18 3102501100 GUIDE SUPPORT 1 SECC T1.219 3102402600 GRILLE COND. 1 PE 660x525.5xT3.520 3100601903 BRACKET MOTOR 1 SBHG1 T1.2
3108008900 1 YDK-30-6B DSB-F074LH21 MOTOR ODU
22 3101801000 FAN PROPELLER 1 ABS+G/F20% (BLACK)23 7400208411 WASHER PLAIN 1 PW-2-8 MFZN24 7392800011 NUT LOCK 1 M8xP1.25 MFZN25 3114504110 PLATE PARTITION 1 SGCC T1.026 314201900 PANEL CONTROL 1 SBHG1 T0.827 3108912310 TERMINAL BLOCK 1 SN-DBW-05P
3109505720 1 1.8+30F / 450VAC DSB-F074LH28 CAPACITOR DUAL
Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
53
No PART CODE PART NAME Q'TY SPEC REMARK
29 3101201100 CLAMP CAPACITOR 1 SBHG1 T1.030 3101202000 CLAMP CORD 1 NYLON 31 3110801500 CABINET FRONT 1 SECC T0.832 3112402500 GRILLE DISCHARGE 1 RECTANGULAR33 3103510700 LABEL BRAND 1 P.CFILM 346x90xT0.434 3100801300 CABINET SIDE 1 SECC T0.835 3104201800 PANEL TOP 1 SECC T0.836 3102600300 HANDLE 1 A.E.S T2.5 (WH104A)37 3102101000 FOOT CUSHION 4 NBR
54
DSB-F074LH
5 CONTROL BOX ASSEMBLY
55
DSB-F074LH
No PART CODE PART NAME Q'TY SPEC REMARK
13114302030
CONTROL PCB ASS'Y 1DSB-F074LH
2 3108003900 MOTOR STEPPING 1 MP24GA , GSP-24SW-061
3 3108914300 TERMINAL BLOCK 1 JXO-CH-05P 600V 30A
5 3104896300 SENSOR ID ASS'Y 1 PTM-KD43C-D2
6 3101300100 POWER CORD ASS'Y 1 250V 16A H05VV-F 3 x 1.0mm2
7 3102797610 HARNESS I/D COMP 1 UL1015 #18 BLU
8 3102797150 HARNESS 4WAY VALVE 1 UL1015 #20 BLK
9 3102704400 HARNESS O/D MOTOR 1 UL1015 #20 WHT
10 3102797910 HARNESS I/D EARTH 1 UL1015 #16 GRN/YEL
11 3102704000 HARNESS POWER 1 UL105 2 x #16 BRN,BLU
12 3102702200 HARNESS TH3 1 UL2464 2x #24 x 6000
13 3102704500 HARNESS LED PCB 1 UL1007 8x #24 WHT
14 3101204600 CLAMP CORD 1 DA-4N
15 3106900300 CAPACITOR IDU 1 1.0 F 400VAC
Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need thelatest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).