Dell Compellent Storage Center

XenServer 6.x Best Practices

Page 2: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 2

Page 3: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 3

Document revision

Date Revision Description

2/16/2009 1 Initial 5.0 Documentation

5/21/2009 2 Documentation update for 5.5

10/1/2010 3 Document Revised for 5.6 and iSCSI

MPIO

12/21/2010 3.1 Updated iSCSI information

8/22/2011 4.0 Documentation updated for 6.0

11/29/2011 4.1 Update for Software iSCSI information

THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN

TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT

EXPRESS OR IMPLIED WARRANTIES OF ANY KIND.

© 2011 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without

the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell.

Dell, the DELL logo, the DELL badge, and Compellent are trademarks of Dell Inc. Other trademarks and

trade names may be used in this document to refer to either the entities claiming the marks and names

Page 4: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 4

or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than

its own.

Page 5: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 5

Contents Document revision ................................................................................................. 3

Contents .................................................................................................................. 5

General syntax ..................................................................................................... 8

Conventions ......................................................................................................... 8

Preface ................................................................................................................... 9

Audience ............................................................................................................ 9

Purpose .............................................................................................................. 9

Customer support .................................................................................................. 9

Introduction ........................................................................................................... 10

XenServer Storage Overview ........................................................................................ 11

XenServer Storage Terminology ............................................................................... 11

Shared iSCSI Storage............................................................................................. 11

Shared Fibre Channel Storage ................................................................................. 12

Shared NFS ........................................................................................................ 13

Volume to Virtual Machine Mapping .................................................................... 14

NIC Bonding vs. iSCSI MPIO ................................................................................ 14

Multi-Pathing ..................................................................................................... 15

Enable Multi-pathing in XenCenter...................................................................... 15

Software iSCSI ......................................................................................................... 16

Overview .......................................................................................................... 16

Open iSCSI initiator Setup with Dell Compellent ........................................................... 17

Multipath with Dual Subnets ................................................................................... 17

Configuring Dedicated Storage NIC ...................................................................... 18

To Assign NIC Functions using the XE CLI ............................................................... 18

XenServer Software iSCSI Setup.......................................................................... 19

Login to Compellent Control Ports ...................................................................... 19

Configure Server Objects in Enterprise Manager ..................................................... 20

View Multipath Status ..................................................................................... 22

Multi-path Requirements with Single Subnet ............................................................... 23

Configuring Bonded Interface ............................................................................ 23

Configuring Dedicated Storage Network ............................................................... 24

To assign NIC functions using the XE CLI: .............................................................. 25

XenServer Software iSCSI Setup.......................................................................... 25

Page 6: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 6

Configure Server Objects in Enterprise Manager ..................................................... 27

Multi-path Requirements with Dual Subnets, Legacy Port Mode ........................................ 28

Log in to Dell Compellent iSCSI Target Ports .......................................................... 30

View Multipath Status ..................................................................................... 33

iSCSI SR Using iSCSI HBA ........................................................................................ 33

Fibre Channel ......................................................................................................... 38

Overview .......................................................................................................... 38

Adding a FC LUN to XenServer Pool .......................................................................... 38

Data Instant Replay to Recover Virtual Machines or Data ................................................ 40

Overview ..................................................................................................... 40

Recovery Option 1 – One VM per LUN ........................................................................ 40

Recovery Option 2 – Recovery Server ........................................................................ 50

Dynamic Capacity ..................................................................................................... 62

Dynamic Capacity Overview .............................................................................. 62

Dynamic Capacity with XenServer ....................................................................... 62

Data Progression ...................................................................................................... 63

Data Progression on XenServer ........................................................................... 63

Boot from SAN ......................................................................................................... 64

VM Metadata Backup and Recovery ............................................................................... 65

Backing Up VM MetaData ....................................................................................... 65

Importing VM MetaData ......................................................................................... 67

Disaster Recovery ..................................................................................................... 68

Replication Overview ........................................................................................... 68

Test XenServer Disaster Recovery ....................................................................... 70

Recovering from a Disaster .................................................................................... 73

Replication Based Disaster Recovery ......................................................................... 77

Disaster Recovery Replication Example ................................................................ 77

Live Volume ....................................................................................................... 82

Overview .......................................................................................................... 82

Appendix 1 Troubleshooting ........................................................................................ 84

XenServer Pool FC Mapping Issue ............................................................................. 84

Starting Software iSCSI ......................................................................................... 85

Two ways to Start iSCSI ................................................................................... 86

Software iSCSI Fails to Start as Server Boot ................................................................. 86

Wildcard Doesn’t Return All Volumes ........................................................................ 86

Page 7: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 7

View Multipath Status ........................................................................................... 87

XenCenter GUI displays Multipathing Incorrectly .......................................................... 87

Connectivity issues with a Fibre Channel Storage Repository ........................................... 88

Page 8: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 8

General syntax Figure 1, Document Syntax

Item Convention

Menu items, dialog box titles, field names, keys Bold

Mouse click required Click:

User Input Monospace Font

User typing required Type:

Website addresses http://www.compellent.com

Email addresses [email protected]

Conventions

Notes are used to convey special information or instructions.

Timesavers are tips specifically designed to save time or reduce the number of steps.

Caution indicates the potential for risk including system or data damage.

Warning indicates that failure to follow directions could result in bodily harm.

Page 9: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 9

Preface

Audience The audience for this document is System Administrators who are responsible for the setup and

maintenance of Citrix XenServer and associated storage. Readers should have a working knowledge of

the installation and management of Citrix XenServer and the Dell Compellent Storage Center.

Purpose This document provides best practices for the setup, configuration and management of Citrix XenServer

with Dell Compellent Storage Center. This document is highly technical and intended for storage and

server administrators as well as information technology professionals interested in learning more about

how Citrix XenServer integrates with Compellent Storage Center.

Customer support Dell Compellent provides live support 1-866-EZSTORE (866.397.8673), 24 hours a day, 7 days a week,

365 days a year. For additional support, email Dell Compellent at [email protected]. Dell

Compellent responds to emails during normal business hours.

Additional information on XenServer 6.0 can be found in the Citrix XenServer 6.0 Administration Guide

located on the Citrix download site. Information on Dell Compellent Storage Center is located on the

Dell Compellent Knowledge Center.

Page 10: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 10

Introduction This document will provide configuration examples, tips, recommended settings, and other storage

guidelines a user can follow while integrating Citrix XenServer with the Dell Compellent Storage

Center. This document has been written to answer many frequently asked questions with regard to

how XenServer interacts with the Dell Compellent Storage Center's various features such as Dynamic

Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer

6.0, however most of the concepts apply to XenServer 5.X unless otherwise noted.

Dell Compellent advises customers to read XenServer documentation which are publically available on

the Citrix XenServer knowledge base documentation pages to provide additional information on

installation and configuration.

This document assumes the reader has had formal training or has advanced working knowledge of the

following:

• Installation and configuration of Citrix XenServer

• Configuration and operation of the Dell Compellent Storage Center

• Operating systems such as Windows or Linux

• The Citrix XenServer 6.0 Administrators Guide NOTE: the information contained within this document is based on general circumstances and

environments. Actual configuration may vary in different environments.

Page 11: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 11

XenServer Storage Overview

XenServer Storage Terminology In working with XenServer 6.0, there are four object classes that are used to describe, configure, and manage storage:

• Storage Repositories (SRs) are storage targets containing homogeneous virtual disks (VDIs). SR commands provide operations for creating, destroying, resizing, cloning, connecting and discovering the individual VDIs that they contain. A storage repository is a persistent, on-disk data structure. So the act of "creating" a new SR is similar to that of formatting a disk -- for single LUN-based SR types, i.e. LVM over iSCSI or Fibre Channel, the creation of a new SR involves erasing any existing data on the specified LUN. SRs are long-lived, and may in some cases be shared among XenServer Hosts, or moved between them. The interface to storage hardware allows VDIs to be supported on a large number of SR types. With built-in support for IDE, SATA, SCSI and SAS drives locally connected, and iSCSI and Fibre Channel remotely connected, the XenServer host SR is very flexible. Each XenServer host can access multiple SRs in parallel of any type. When hosting direct attached shared Storage Repositories on a Dell Compellent Storage Center, there are 2 options; an iSCSI connected LUN or a Fibre Channel connected LUN.

• Physical Block Devices (PBDs) represent the interface between a physical server and an attached SR. PBDs are connector objects that allow a given SR to be mapped to a XenServer Host. PBDs store the device configuration fields that are used to connect to and interact with a given storage target. PBD objects manage the run-time attachment of a given SR to a given XenServer Host.

• Virtual Disk Images (VDIs) are an on-disk representation of a virtual disk provided to a VM. VDIs are the fundamental unit of virtualized storage in XenServer. Similar to SRs, VDIs are persistent, on-disk objects that exist independently of XenServer Hosts.

• Virtual Block Devices (VBDs) are a connector object (similar to the PBD described above) that allows mappings between VDIs and Virtual Machines (VMs). In addition to providing a mechanism to attach (or plug) a VDI into a VM, VBDs allow fine-tuning of parameters regarding QoS (quality of service), statistics, and the boot ability of a given VDI.

Shared iSCSI Storage Citrix XenServer on Dell Compellent Storage provides support for shared SRs on iSCSI attached LUNs.

iSCSI is supported using the open-iSCSI software initiator or a supported iSCSI Host Bus Adapter (HBA).

Shared iSCSI support is implemented based on a Logical Volume Manager (LVM). LVM-based storage is

high-performance and allows virtual disks to be dynamically resized. Virtual disks are fully allocated as

an isolated volume on the underlying physical disk and so there is a minimum of storage virtualization

overhead imposed. As such, this is a good option for high-performance storage.

Below is a diagrammatic representation of using shared storage with iSCSI HBAs in XenServer. The

second diagram illustrates shared storage with the open iSCSI initiator.

Page 12: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 12

Figure 2, Shared iSCSI Storage with iSCSI HBA

Figure 3, Shared iSCSI with Software Initiator

Shared Fibre Channel Storage XenServer hosts with Dell Compellent Storage supports Fibre Channel SANs using the Emulex or QLogic

host bus adapters (HBAs). Logical unit numbers (LUNs) are mapped to the XenServer host as disk

devices. Like HBA iSCSI storage, Fibre Channel storage support is implemented based on the same

Logical Volume Manager with the same benefits as iSCSI storage, just utilizing a different data I/O

path.

Page 13: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 13

Figure 4, Shard Fibre Channel Storage

Shared NFS XenServer supports NFS file servers, such as the Dell NX3000 with Dell Compellent storage to host SRs.

NFS storage repositories can be shared within a resource pool of XenServers. This allows virtual

machines to be migrated between XenServers within the pool using XenMotion.

Attaching an NFS storage repository requires the hostname or IP address of the NFS server. The NFS

server must be configure to export the specified path to all XenServers in a pool or the reading of the

SR will fail.

Using and NFS share is a relatively simple way to create an SR and doesn’t involve the complexity of

iSCSI or expense of Fibre Channel. There are some limitations that must be considered before

implementing NFS however. An NFS SR will utilize a similar network infrastructure as iSCSI to support

redundant paths to the NFS share. The main difference is that iSCSI uses MPIO to support multipathing

and load balancing between multiple the paths while NFS is limited to one network interface per SR.

Redundancy in an NFS environment can be accomplished by using XenServer bonded interfaces.

Bonded interfaces are active/passive and won’t provide load balancing across both physical adapters

such as iSCSI can provide.

Page 14: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 14

Figure 5, Shared NFS SR

A new feature with XenServer 6.0 is the ability to provide a high availability (HA) quorum disk on an

NFS volume. However, the XenServer 6.0 Disaster Recovery feature can only be enabled when using

LVM over HBA or software iSCSI. The underlying protocol choice for SRs is a business decision that will

be unique to each environment. Given the performance benefits and the requirement for Disaster

Recovery it is the recommendation of Dell Compellent to use iSCSI or FC HBA, or software iSCSI over

NFS.

Volume to Virtual Machine Mapping

XenServer is fully capable of deploying a many-to-one VM-to-volume (LUN) deployment. The number of

VM on a volume is dependent on the workload and IOPS requirement of the VM. When multiple virtual

disks share a volume they also share the disk queue for that volume on the host. For this reason, care

should be taken to prevent a bottleneck condition on the volume. Additionally, replication and DR

become a factor when hosting multiple VMs on a volume. This is due to replication and recovery taking

place on a per-volume basis.

NIC Bonding vs. iSCSI MPIO

NIC bonds can improve XenServer host resiliency by using two physical NICs as if they were one. If one

NIC within the bond fails the host's network traffic will automatically be routed over the second NIC.

NIC bonds supports active/active mode, but only supports load-balancing of VM traffic across the

physical NICS. Any given virtual network interface will only use one of the links in the bond at a time.

Load-balancing is not available for non-VM traffic.

MPIO also provides host resiliency by using two physical NICs. MPIO uses round robin to balance the

Storage traffic between separate targets on the Dell Compellent Storage Center. By spreading the load

between multiple Dell Compellent Target iSCSI bottlenecks can be avoided while providing network

adapter, subnet, and switch redundancy.

If all Front End iSCSI ports on the Dell Compellent System are on the same subnet, then NIC bonding is

the better option since XenServer iSCSI MPIO requires at least two separate subnets. In this

configuration all iSCSI connections will use the same physical NIC because Bonding does not support

Page 15: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 15

active/active connections for anything but VM traffic. For this reason, it is recommended that front

end iSCSI ports across be configured two subnets. This allows load balancing across all NICs and

failover with MPIO.

Multi-Pathing Multi-Pathing allows for failures in HBAs, Switch Ports, Switches, and SAN IO ports. It is recommended

to utilize Multi-Pathing to increase availability and redundancy for critical systems such as production

deployments of XenServer when hosting critical servers.

XenServer supports Active/Active Multi-Pathing for iSCSI and FC protocols for I/O datapaths. Dynamic

Multi-Pathing uses a round-robin mode load balancing algorithm, so both routes will have active traffic

on them during normal operations. Multi-Pathing can be enabled via XenCenter or on the command

line. Please see the XenServer 6.0 Administrator Guide for information on enabling Multi-Pathing on

XenServer hosts. Enabling Multi-Pathing requires a server restart and should be enabled before storage

is added to the server. Only use Multi-Pathing when there are multiple paths to the storage center.

Enable Multi-pathing in XenCenter

1. Right click on the server in XenCenter and select “Enter Maintenance Mode”

2. Right click on the server and select “Properties”

3. In the Properties window, select “Multipathing”

4. Check the “Enable Multipathing on this server” box and click OK

5. The server will need to be restarted for Multipathing to take affect

Figure 6, Enable Multipathing

Page 16: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 16

Software iSCSI

Overview XenServer Supports shared Storage Repositories (SRs) on iSCSI LUNs. iSCSI is implemented using the

open-iSCSI software initiator or by using a supported iSCSI HBAs. XenServer iSCSI Storage Repositories

are supported with Dell Compellent Storage Center running in either Legacy mode or Virtual Port

mode.

Shared iSCSI using the software iSCSI initiator is implemented based on the Linux Volume Manager

(LVM) and provides the same performance benefits provided by LVM on local disks. Shared iSCSI SRs

using the software-based host initiator are capable of supporting VM agility. Using XenMotion, VMs can

be started on any XenServer host in a resource pool and migrated between them with no noticeable

interruption.

iSCSI SRs utilize the entire LUN specified at creation time and may not span more than one LUN. CHAP

support is provided for client authentication, during both the data path initialization and the LUN

discovery phases.

NOTE: Use dedicated network adapters for iSCSI traffic. The default connection can be used however

it is always best practice to separate iSCSI and network traffic.

All iSCSI initiators and targets must have a unique name to ensure they can be identified on the

network. An initiator has an iSCSI initiator address, and a target has an iSCSI target address.

Collectively these are called iSCSI Qualified Names, or IQNs.

XenServer hosts support a single iSCSI initiator which is automatically created and configured with a

random IQN during host installation. iSCSI targets commonly provide access control via iSCSI initiator

IQN lists, so all iSCSI targets/LUNs to be accessed by a XenServer host must be configured to allow

access by the host's initiator IQN. Similarly, targets/LUNs to be used as shared iSCSI SRs must be

configured to allow access by all host IQNs in the resource pool.

iSCSI targets that do not provide access control will typically default to restricting LUN access to a

single initiator to ensure data integrity. If an iSCSI LUN is intended for use as a shared SR across

multiple XenServer hosts in a resource pool ensure that multi-initiator access is enabled for the

specified LUN.

It is strongly suggested to change the default XenServer IQN to one that is consistent with a naming

schema in the iSCSI environment. The XenServer host IQN value can be adjusted using XenCenter, or

via the CLI with the following command when using the iSCSI software initiator:

xe host-param-set uuid=<valid_host_id> other-config:iscsi_iqn=<new_initiator_iqn>

Caution: It is imperative that every iSCSI target and initiator have a unique IQN. If a non-unique IQN

identifier is used, data corruption and/or denial of LUN access can occur.

Caution: Do not change the XenServer host IQN with iSCSI SRs attached. Doing so can result in failures

connecting to new targets or existing SRs.

Page 17: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 17

Open iSCSI initiator Setup with Dell Compellent

Caution: Issues have been identified with the Citrix implementation of multipathing and Storage

Center in virtual port mode. It is strongly recommended to use iSCSI HBAs when implementing

XenServer with Storage Center in virtual port mode.

When planning iSCSI it is important that networks used for software-based iSCSI have separate

switching and different subnets from those used for management. The use of separate subnets ensures

that management and storage traffic flows over the intended interface and avoids complex

workarounds that may compromise reliability or performance.

If planning to utilize iSCSI storage with Multi-Pathing, it is important to ensure that none of the

redundant paths reported by iSCSI are within the same subnet as the management interface. If this

occurs the iSCSI initiator may not be able to successfully establish a session over each path because the

management interface comes up separate to the storage interface(s).

There are three options when implementing the XenServer software iSCSI initiator to connect to Dell

Compellent storage. They are:

• Multipath with dual subnets, virtual port mode - In this configuration the Storage Center is set

to Virtual Port mode and the front end controller ports are on two separate subnets. This

option uses MPIO for multipathing. This is the recommended option when HA is required.

• Multipath with single subnet - In this configuration the Storage Center is set to Virtual Port

mode and all controller front end ports are on the same subnet. This option uses NIC Bonding

for path failover. This is also an option when the servers have a single iSCSI Storage NIC and HA

is not required.

• Multipath with dual subnets, Legacy port mode - This is the option for HA when the Storage

Center is set to Legacy Port mode.

Multipath with Dual Subnets The requirements for software iSCSI Multi-pathing with dual subnets and Compellent Storage Center in

virtual port mode are as follows:

• XenServer 6.0

• iSCSI using 2 unique dedicated storage NICs/subnets

o Citrix best practices states that these 2 subnets should be different from the XenServer

management network.

• Multi-pathing enabled on all XenServer pool hosts

• iSCSI Target IP addresses for the Storage Center Front End Control ports

o In the example below the iSCSI FE Control ports on Storage Center Controller are

assigned IP address 10.25.0.10/16 and 10.26.0.10/16

In this configuration the Storage Center is set to virtual port mode and the iSCSI Front End ports are

on two separate subnets different from the management interface. The Storage Center is

configured with two control ports, one for each subnet. Multipathing is controlled through MPIO.

Page 18: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 18

Figure 7, Dual Subnet, MPIO

Configuring Dedicated Storage NIC

XenServer allows use of either XenCenter or the XE CLI to configure and dedicate a NIC to specific

functions, such as storage traffic.

Assigning a NIC to a specific function will prevent the use of the NIC for other functions such as host

management, but requires that the appropriate network configuration be in place to ensure the NIC is

used for the desired traffic. For example, to dedicate a NIC to storage traffic the NIC, storage target,

switch, and/or VLAN must be configured so the target is only accessible over the assigned NIC.

Ensure that the dedicated storage interface uses a separate IP subnet which is not routable from the

main management interface. If this is not enforced, storage traffic may be directed over the main

management interface after a host reboot due to the order in which network interfaces are initialized.

To Assign NIC Functions using the XE CLI

1. Ensure that the Physical Interface (PIF) is on a separate subnet, or routing is configured to suit your

network topology in order to force the desired traffic over the selected PIF.

2. Get the PIF UUID for the interface

2.1. If on a stand-alone server, use xe pif-list to list the PIFs on the server

2.2. If on a host in a resource pool, first type xe host-list to retrieve a list of the hosts and

UUIDs

2.3. Use the command xe pif-list host-uuid=<host-uuid> to list the host PIFs

Page 19: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 19

3. Setup an IP configuration for the PIF, adding appropriate values for the mode parameter and if

using static IP addressing the IP, netmask, gateway, and DNS parameters:

xe pif-reconfigure-ip mode=<DHCP | Static> uuid=<pif-u uid>

Example: xe pif-reconfigure-ip mode=static ip=10.0.0.10

netmask=255.255.255.0 gateway=10.10.0.1 uuid=<PIF-U UID>

4. Set the PIF's disallow-unplug parameter to true:

xe pif-param-set disallow-unplug=true uuid=<PIF-UUI D>

5. Set the Management Purpose of the interface:

xe pif-param-set other-config:management_purpose="S torage" uuid=<PIF-UUID>

6. Repeat this process for each eth interface in the XenServer host that will be dedicated for storage

traffic. For iSCSI MPIO configurations this should be a minimum of two eth interfaces that are on

separate subnets.

For more information on this topic see the Citrix XenServer 6.0 Administrator Guide.

XenServer Software iSCSI Setup

A server object on the Dell Compellent Storage Center can be created once the XenServer has been

configured for iSCSI traffic.

NOTE: Best practice recommendation is to change the XenServer IQN from the randomly assigned IQN

to one that identifies the system on the iSCSI network. The IQN must be unique to avoid data

corruption or loss.

Gather Dell Compellent iSCSI Target Info

Within Storage Center Manager, go to Controllers, IO Cards, iSCSI and note the IP address of the two

control ports. These should be on the same IP subnet as the server’s storage NICs.

Figure 8, Control Port IP Addresses

In this example the IP addresses are:

10.25.0.10/16

10.26.0.10/16

Login to Compellent Control Ports

In this step the iscsiadm command will be utilized in the XenServer CLI to discover and login to all the

Compellent iSCSI targets.

1. From the XenServer console run the following command for each iSCSI control ports.

Page 20: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 20

iscsiadm -m discovery --type sendtarget --portal <C ontrol Port IP:3260>

Example: iscsiadm –m discovery --type stendtarget --portal 1 0.25.0.10:3260

Figure 9, Discover Storage Center Ports

NOTE: If problems are encountered while running the iscsiadm commands, see the iSCSI

Troubleshooting section at the end of this document.

2. Repeat the discovery process for each Dell Compellent Control Port.

3. Once all target ports are discovered run iscsiadm with the Login parameter:

iscsiadm –m node --login

Figure 10, Log into Storage Center Ports

The server objects can be configured in the Storage Center now that the server has logged in.

Configure Server Objects in Enterprise Manager

Follow the steps below to configure the server object for access to the Storage Center

1. In Enterprise Manager, go to Storage Center and select Storage Management

2. In the object tree, right click on Servers and select Create Server

3. Complete all options as specific in the Compellent Administrators guide

4. Uncheck the “Use iSCSI Name” box

5. Select both connections listed under WWName and click OK to finish

NOTE: Unchecking the “Use iSCSI Name” box will aid in identifying the status of MPIO paths.

Page 21: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 21

Figure 11, Create Server, Enterprise Manager

NOTE: Starting in Storage Center version 5.5.x, the steps listed above must be completed using

Enterprise Manager. It is not possible to create server objects with the “Use iSCSI Names” box

unchecked when connected directly to the Storage Center.

After creating the server object the volumes can be created and mapped to the server. In a server

pool, map the LUN to all servers specifying the same LUN number. See the Dell Compellent

documentation for detailed instructions on creating and mapping volumes.

NOTE: Use Server Cluster objects to map volumes to multiple servers in a resource pool.

Once the volumes are mapped to the server they can be added to the XenServer using XenCenter or the

CLI. Below are the steps for adding storage using XenCenter The steps for adding storage through the

CLI can be found in the XenServer 6.0 Administrator’s Guide.

1. Select the server or pool in XenCenter and click on New Storage

2. Select the Software iSCSI option under virtual disk storage, click next

Figure 12, Add iSCSI Disk

3. Give the new Storage Repository a name and click next

4. Enter one of the Dell Compellent control ports in the “Target Host” field, click Discover IQNs

5. Click Discover LUNs

6. Select the LUN to add under “Target LUN” and click finish

Page 22: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 22

Figure 13, Add iSCSI SR

NOTE: When the Storage Center is in virtual port mode and adding storage with the wildcard option, an

incomplete list of volumes mapped to the server may be returned. This is a know issue with the

XenCenter GUI. To work around the issue, cycle through the Control Ports in the Target Host field

using the (*) wildcard Target IQNs until the Target LUN appears. This is a GUI issue and will not affect

multipathing.

The SR should now be available to the server. Repeat the steps for mapping and adding storage for any

additional SRs.

View Multipath Status

To view the status of the multipath use the following command:

mpathutil status

Figure 14, Multipath Status

Page 23: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 23

Multi-path Requirements with Single Subnet The process for configuring multi-pathing in a single subnet environment is similar to that of a dual

subnet environment. The key difference is that redundancy is handled by the bonded network

adapters. The requirements for software iSCSI multi-pathing with the Compellent Storage Center in a

single subnet are as follows:

• XenServer 6.0

• iSCSI using 2 bonded NICs

o Citrix best practices states that these 2 NICs should bonded through the XenCenter GUI.

• iSCSI Target IP addresses for the Storage Center Front End Control ports

o In this example the IP address for the Control port will be 10.35.0.10

• 1 Network Storage Interfaces on XenServer on the bonded interface.

Figure 15, Single Subnet

Configuring Bonded Interface

In this configuration redundancy to the network is provided by two bonded NICs. Bonding the two NICs

will create a new bonded interface that network interfaces will be associated with. This will create

multiple paths with one storage IP address on the server.

Page 24: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 24

NOTE: The process of configuring a single-path, non redundant connection to a Dell Compellent Storage

Center is the same except for excluding the steps to bond the two NICs.

NOTE: Create NIC bonds as part of the initial resource pool creation, prior to joining additional hosts to

the pool. This will allow the bond configuration to be replicated to new hosts as they join the pool.

The steps below outline the process of creating a NIC bond in XenServer 6.0

1. Go into Citrix XenCenter, select the server and go to the NIC tab.

2. At the bottom of the NIC window is the option to create a bond. Select the NICs you would like

to bond and click create.

Figure 16, Add Bonded Interface

3. Once complete, there will be a new bonded NIC displayed in the list of NICs.

Figure 17, Bonded Interface

Configuring Dedicated Storage Network

XenServer allows use of either XenCenter or the XE CLI to configure and dedicate a network to specific

functions, such as storage traffic. The steps below outline the process of creating a dedicated storage

network interface through the CLI.

Assigning a network to storage will prevent the use of the network for other functions such as host

management, but requires that the appropriate configuration be in place in order to ensure the

network is used for the desired traffic. For example, to dedicate a network to storage traffic the NIC,

storage target, switch, and/or VLAN must be configured such that the target is only accessible over the

assigned NIC. This allows use of standard IP routing to control how traffic is routed between multiple

NICs within a XenServer.

Page 25: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 25

Before dedicating a network interface as a storage interface for use with iSCSI SRs, ensure that the

dedicated interface uses a separate IP subnet which is not routable from the main management

interface. If this is not enforced, then storage traffic may be directed over the main management

interface after a host reboot, due to the order in which network interfaces are initialized.

To assign NIC functions using the XE CLI:

1. Ensure that the Bond PIF is on a separate subnet, or routing is configured to force the desired

traffic over the selected PIF.

2. Get the PIF UUID for the Bond interface

2.1. If on a stand-alone server, use xe pif-list to list the PIFs on the server 2.2. If on a host in a resource pool, first type xe host-list to retrieve a list of the hosts and UUIDs 2.3. Use the command xe pif-list host-uuid=<host-uuid > to list the host PIFs

3. Setup an IP configuration for the PIF identified in the previous step, adding appropriate values for

the mode parameter and if using static IP addressing:

3.1. xe pif-reconfigure-ip mode=<DHCP | Static > uuid=<pif-uuid >

Example: xe pif-reconfigure-ip mode=static ip=10.0.0.10 netmask=255.255.255.0 gateway=10.10.0.1

uuid=<3f5a072f-ea3b-de28-aeab-47c7d7f2b58f >

4. Set the PIF's disallow-unplug parameter to true:

4.1. xe pif-param-set disallow-unplug=true uuid=<PIF-UUID>

5. Set the Management Purpose of the interface

5.1. xe pif-param-set other-config:management_purpose="Storage" uuid=<PIF-UUID>

For more information on this topic see the Citrix XenServer 6.0 Administrator Guide.

XenServer Software iSCSI Setup

Once the XenServer has been configured for iSCSI traffic a server object on the Dell Compellent Storage

Center can be created.

NOTE: Best practice is to change the XenServer IQN from the randomly assigned IQN to one that

identifies the system on the iSCSI network. The IQN must be unique to avoid data corruption or loss.

1. To gather the Storage Center iSCSI target Info from Storage Center go to Controllers, IO Cards,

iSCSI and note the IP address of the control port. It should be on the same IP subnet as the server’s

storage NICs.

Page 26: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 26

Figure 18, Control Port IP address

In this example the IP address is:

10.35.0.10/16

2. Login to Compellent Control Ports. In this step the iscsiadm command will be utilized in the

XenServer CLI to discover and login to all the Dell Compellent iSCSI targets.

3. From the XenServer console, run the following command for the iSCSI control port.

iscsiadm -m discovery --type sendtarget --portal <C ontrol Port IP:3260>

Example: iscsiadm –m discovery --type sendtarget --portal 10 .25.0.10:3260

Figure 19, Discover Storage Center Ports

NOTE: If problems are encountered while running the iscsiadm commands, see the iSCSI

troubleshooting section at the end of this document.

4. Once all target ports are discovered, run iscsiadm with the Login parameter:

iscsiadm –m node --login Figure 20, log into Storage Center Ports

5. Now that the server has logged in the server objects can be configured in the Storage Center.

Page 27: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 27

Configure Server Objects in Enterprise Manager

Follow the steps below to configure the server object for access to the Storage Center

1. In Enterprise Manager, go to Storage Center Manager and select Storage Management In the object

tree.

2. Right click on Servers and select Create Server. Complete all options as specific in the Compellent

Administrators Guide including server name and operating system.

3. Select the server IQN listed under WWName and click OK to finish

Figure 21, Create Server in Enterprise Manager

After creating the server object the volumes can be created and mapped to the server. In a server

pool, be sure the LUNS are mapped to the servers with the same LUN number. See the Dell Compellent

Admin Guide for detailed instructions on creating and mapping volumes.

NOTE: Use Server Cluster objects to map volumes to multiple servers in a resource pool.

Once the volumes are mapped to the server they can be added to the XenServer using XenCenter or the

CLI. Below are the steps for adding storage using XenCenter. Steps for adding storage through the CLI

can be found in the XenServer 6.0 Administrator’s Guide.

1. Select the server or pool in XenCenter and click on New Storage

2. Select the Software iSCSI option under virtual disk storage, click next

Page 28: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 28

Figure 22, Add iSCSI Disk

3. Give the new Storage Repository a name and click next

4. Enter the Dell Compellent control port in the “Target Host” field, click Discover IQNs

5. Click Discover LUNs to view the available LUNs.

Figure 23, Add iSCSI SR

6. Select the LUN to add under “Target LUN” and click finish

NOTE: When the Storage Center is in virtual port mode and storage is added with the wildcard option,

an incomplete list of volumes mapped to the server may be returned. This is a know issue with the

XenCenter GUI. To work around the problem, cycle through the Target Host IP addresses using the (*)

wildcard IQN until the Target LUN appears. This is a GUI issue and will not affect multipathing.

The SR will now be available to the server. Repeat the steps for mapping and adding storage for any

additional SRs.

Multi-path Requirements with Dual Subnets, Legacy Port Mode Dell Compellent Legacy Port Mode uses the concept of Fault Domains to provide redundant paths to the

Storage Center. To ensure redundancy, a fault domain consists of a primary port on one controller and

a failover port on the second controller. The two ports are linked in the same domain by the identical

Fault Domain number. This provides redundancy with the requirement that half the Front End ports

will only be utilized in the event of a failover. The requirements for software iSCSI Multi-pathing with

the Compellent Storage Center Legacy Port Mode are as follows:

Page 29: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 29

• XenServer 6.0

• iSCSI using 2 unique dedicated storage NICs/subnets

o Citrix best practices states that these 2 subnets should be different from the XenServer

management network.

• Multi-pathing enabled on all XenServer Pool Hosts

• iSCSI Target IP addresses for the Storage Center Front End ports

o In this example the primary iSCSI Front End ports IP address are 10.10.63.2, 10.10.62.1,

172.31.37.134, 172.31.37.131

In this configuration the Storage Center is set to Legacy Port mode and the iSCSI Front End ports

are on two subnets separate from each other and the management interface. Multipathing is

controlled through MPIO.

Figure 24, Legacy Port Mode

The first step to configure XenServer for Dell Compellent in Legacy Port mode is to identify the primary

iSCSI target IP addresses on each controller the Storage Center. This can be done by going to the

controllers listed in Storage Center, expanding IO cards, iSCSI and clicking on each iSCSI port listed.

Page 30: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 30

Figure 25, Legacy Port IP addresses

Log in to Dell Compellent iSCSI Target Ports

This step uses the iscsiadm command in the XenServer CLI to discover and login to all the Compellent

iSCSI targets.

1. For each of the Target IP addresses enter the following command:

iscsiadm -m discovery --type sendtarget --portal <c ontrol port ip:3260>

Example: iscsiadm -m discovery --type sendtarget --portal 10 .10.62.1:3260

Figure 26, Discover Storage Center Ports

2. Repeat the discovery process for each Target Port

3. Once all the ports are discovered, run the iscsiadm command with Login parameter to connect the

host to the Storage Center

Iscsiadm -m node --login

Figure 27, log into Storage Center Ports

Configure Server Objects in Enterprise Manager

Follow the steps below to configure the server object for access to the Storage Center

1. In Enterprise Manager, go to Storage Center and select Storage Management

2. In the object tree, right click on Servers and select Create Server

3. Complete all options as specified in the Dell Compellent Administrators Guide.

Page 31: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 31

Figure 28, Create Server in Enterprise Manager

After creating the server object the volumes can be created and mapped to the server. See the Dell

Compellent documentation for detailed instructions on creating and mapping volumes.

NOTE: Use Server Cluster objects to map volumes to multiple servers in a resource pool.

Once the volumes are mapped to the server they can be added to the XenServer using XenCenter or the

CLI. Below are the steps for adding storage using XenCenter. Steps for adding storage through the CLI

can be found in the XenServer 6.0 Administrator’s Guide.

1. Select the server or Pool in XenCenter and click on New Storage

2. Select the Software iSCSI option under virtual disk storage, click next

Figure 29, Add iSCSI Disk

3. Give the new Storage Repository a name and click Next

4. Enter the Dell Compellent control ports in the “Target Host” filed, click Discover IQNs

Page 32: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 32

Figure 30, Discover Storage Center LUNs

5. Click Discover LUNs

Figure 31, Add iSCSI SR

6. Select the LUN to add under “Target LUN” and click finish

NOTE: When Storage Center is in legacy port mode adding storage may return an incomplete list of

volumes mapped to the server. This is a know issue with the XenCenter GUI where only the LUNs

active on the first IP address in Target Host are returned. To work around this issue, cycle through the

Target Hosts IP using the (*) wildcard Target IQN until the Target LUN appears. This is a GUI issue and

will not affect multipathing.

Page 33: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 33

The SR will now be available to the server. Repeat the steps above for mapping and adding storage for

any additional SRs.

View Multipath Status

To view the status of the multipath use the following command:

mpathutil status

Figure 32, Multipath Status

iSCSI SR Using iSCSI HBA If using an iSCSI HBA to create the iSCSI SR, either the CLI from the control domain needs to be used, or

the BIOS level management interface needs to be updated for target information. Depending on what

HBA is being used; the initiator IQN for the HBA needs to be configured. Given the type of HBA used,

the documentation for that HBA should be consulted to configure the IQN. Once the IQN has been

configured for the HBA, use the Storage Center GUI to create a new LUN. However, instead of using the

XenServer‘s IQN, specify the IQN of the various ports of the HBA. Do this for every XenServer host in

the pool. Qlogic’s HBA CLI in included in the XenServer host and located at:

Qlogic: /opt/QLogic_Corporation/SANsurferiCLI/iscli

If using Emulex iSCSI HBAs, consult the Emulex documentation for instructions on installing and

configuring the HBA.

For the purposes of an example, this guide illustrates how the QLogic iSCSI HBA CLI iscli can be used to

configure an IP addresses on a dual port QLE4062C iSCSI HBA Adapter, add the iSCSI server to the

Compellent SAN, and configure a LUN for the server. This setup will also utilize Multi-Pathing since

there are two iSCSI HBA ports.

1. From the XenServer Console launch the SanSurfer iscli. 1.1. From XenServer Command Prompt type in: /opt/QLogic_Corporation/SANsurferiCLI/iscli

NOTE: This configuration can also be performed during the Server boot by entering Ctrl – Q when

prompted.

Page 34: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Figure 33, iSCLI Menu

2. Configure IP Address for the iSCSI HBA

2.1. In order to set the IP address for the HBAthen option 2 (Port Network Settings Menu).

2.2. Enter option 4 (Select HBA Port) to select the appropriate HBA port then select

(Configure IP Settings).

Figure 34, Configure HBA IP Address

2.3. Enter the appropriate IP Settings for the HBA adapter port when finished exit and save or

select another HBA port to configure.

Center XenServer 6.x Best Practices

ess for the iSCSI HBA

set the IP address for the HBA choose option 4 (Port Level Info & Operations)

(Port Network Settings Menu).

(Select HBA Port) to select the appropriate HBA port then select

Enter the appropriate IP Settings for the HBA adapter port when finished exit and save or

select another HBA port to configure.

Page 34

(Port Level Info & Operations), and

(Select HBA Port) to select the appropriate HBA port then select option 2

Enter the appropriate IP Settings for the HBA adapter port when finished exit and save or

Page 35: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

2.3.1. In this example another HBA port

Figure 35, Enter IP Address Information

2.4. From the Port Network Settings Menu select configure. Enter 2 and to select the second HBA port. Once the second HBA port is sel

choose option 2 (Configure IP Settings) from the Port network settings menu to in

appropriate IP settings for the second HBA port.

Figure 36, Enter IP Address Info

Center XenServer 6.x Best Practices

In this example another HBA port will be configured.

rmation

From the Port Network Settings Menu select option 4 to select an additional HBA port to

and to select the second HBA port. Once the second HBA port is sel

(Configure IP Settings) from the Port network settings menu to in

appropriate IP settings for the second HBA port.

Page 35

l HBA port to

and to select the second HBA port. Once the second HBA port is selected

(Configure IP Settings) from the Port network settings menu to input the

Page 36: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

2.5. Choose option 5 (Save changes and reset HBA (if nemain menu.

The iSCSI name or IQN can also be changed using the

option 4 (Port Level info & Operations Menu)

Configured Port Settings menu) then

Advanced Settings). Select <Enter> until reaching iSCSI_Name, then enter a unique IQN name for the

adapter.

3. The next step is to establish a target fCenter. 3.1. From the main interactive 3.2. From the Port Level Info & Operations m

Operations) 3.3. On the HBA target menu screen select

3.3.1. Select Enter until reaching the TGT_TargetIPAddress option. Enter the target IP address of the Compellent Controller. (Repeat for each target.)

3.3.1.1. In this example 10.10.64.1 and 10.10.65.2 are used. TheseiSCSI connection on both

Figure 37, Enter Target IP Address

3.3.2. Once all targets are entered for HBA 0 select information.

3.3.3. Select option 10 to select the second HBA port. 3.3.4. Repeat the steps in section 3.3 for the iSCSI targets.

3.4. Enter option 12 to exit. Enter 3.5. Exit out of the iscli utility.

4. Add server iSCSI connection HBAs to the 4.1. Logon to the Storage Center4.2. Expand Servers and select the location or folder to store the server in.

4.2.1. For ease of use the servers in this view are separated into folders based on function.4.3. Right click the location to create the server in and select

Center XenServer 6.x Best Practices

Choose option 5 (Save changes and reset HBA (if necessary). Then select Exit until back at the

The iSCSI name or IQN can also be changed using the iscli utility. This menu can be access by selecting

(Port Level info & Operations Menu) from the main menu, then selecting Option 3

Configured Port Settings menu) then Option 3 (Port Firmware Settings Menu), then Option 7

Advanced Settings). Select <Enter> until reaching iSCSI_Name, then enter a unique IQN name for the

The next step is to establish a target from XenServer so it registers with the Compellent Storage

nteractive iscli menu select option 4 (Port level info & Operations)e Port Level Info & Operations menu select option 7 (---> Target level Info &

enu screen select option 6 (Add a Target) nter until reaching the TGT_TargetIPAddress option. Enter the target IP

address of the Compellent Controller. (Repeat for each target.) In this example 10.10.64.1 and 10.10.65.2 are used. These are the primary

iSCSI connection on both Dell Compellent Storage Center Controllers.

Once all targets are entered for HBA 0 select option 9 to the save the port

to select the second HBA port. Repeat the steps in section 3.3 for the iSCSI targets.

to exit. Enter YES to save the changes. utility.

Add server iSCSI connection HBAs to the Dell Compellent Storage Center. Storage Center console.

Expand Servers and select the location or folder to store the server in. For ease of use the servers in this view are separated into folders based on function.

Right click the location to create the server in and select Create Server.

Page 36

cessary). Then select Exit until back at the

enu can be access by selecting

Option 3 (Edit

Option 7 (Configure

Advanced Settings). Select <Enter> until reaching iSCSI_Name, then enter a unique IQN name for the

rom XenServer so it registers with the Compellent Storage

(Port level info & Operations) > Target level Info &

nter until reaching the TGT_TargetIPAddress option. Enter the target IP

are the primary Controllers.

to the save the port

For ease of use the servers in this view are separated into folders based on function.

Page 37: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 37

Note: You may have to uncheck show only active/up connections in the create a server wizard

4.4. Select the appropriate iSCSI HBA/IQNs for the new server object then click Continue. 4.5. Depending on the Storage Center version select the XenServer Operating system or just select

Other Multipath OS if XenServer is not listed. 5. Repeat preceding 4 steps for each XenServer in the Pool. 6. Once all the XenServer servers are added to the Compellent Storage Center, create a new volume

on the Compellent Storage Center and map it to all the XenServers in the pool with the same LUN

Number, or create a Compellent Clustered server object, add all the XenServers to the Cluster, and

map the volume to the XenServer Clustered server object.

7. The final step of the process is adding the new Volume to XenServer.

7.1. Logon to XenCenter, right click on the appropriate XenServer to add the connection to, and select New Storage Repository.

If the storage is being added to a resource pool, select the Pool instead of the server.

7.2. Select Hardware HBA option as the iSCSI connection is using iSCSI HBAs, then click Next.

Figure 38, Storage Type

There is short delay while XenServer probes for available LUNs.

7.3. Select the appropriate LUN. Give the SR an appropriate Name and click Finish. 7.4. A warning is displayed that the LUN will be formatted and any data present will be destroyed.

Click Yes to format the disk.

Page 38: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 38

Fibre Channel

Overview XenServer provides support for shared Storage Repositories (SRs) on Fibre Channel (FC) LUNs. FC is

supported on the Dell Compellent SAN by utilizing QLogic or Emulex HBAs.

Fibre Channel support is implemented based on the Linux Volume Manager (LVM) and provides the same

performance benefits provided by LVM VDIs in the local disk case. Fibre Channel SRs are capable of

supporting VM agility using XenMotion: VMs can be started on any XenServer host in a resource pool and

migrated between them with no noticeable downtime.

The following sections details the steps involved in adding a new Fibre Channel connected volume to a

XenServer pool.

Adding a FC LUN to XenServer Pool The following section will cover the creation of the Volume on the Compellent Storage Center, the LUN

mapping on the Dell Compellent, and adding the new SR to the XenServer pool.

This procedure assumes that the servers Fibre Channel connection have been zoned to the Dell

Compellent Storage Center and the server objects have been added to the Storage Center.

1. Once all the XenServer servers are added to the Dell Compellent Storage Center, create a new

volume and map it to all the XenServers in the pool with the same LUN Number, or create a

Compellent Clustered server object, add all the XenServers to the Cluster, and map the volume

to the XenServer Clustered server object.

2. When finished mapping the volume to all the XenServers in the Pool launch the XenCenter Management console, right click on the pool name and select New Storage Repository.

Figure 39, New Storage Repository

3. On the Choose the type of new storage screen select Hardware HBA then click Next.

Page 39: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 39

Figure 40, Choose Storage Type

4. On the Select the LUN to reattach or create a new SR screen select the appropriate volume, then enter a descriptive name. Click Finished to continue.

Figure 41, Select LUN

5. A dialog box will appear asking: Do you wish to format the disk? Click Yes to Format the SR. 6. The SR should now be created and mapped to all the servers in the pool.

Page 40: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 40

Data Instant Replay to Recover Virtual Machines or Data

Overview

The Dell Compellent Storage Center system allows for the creation of Data Instant Replays (snapshots)

to recover crash-consistent states of virtual machines.

When mapping Dell Compellent iSCSI or Fiber Channel volumes to XenServer, the SRs will be created as

LVM disks, therefore stamping each SR with a unique identifier (UUID). When creating Dell Compellent

Replays of LVM volumes, the Replay will not be able to be mapped to the XenServer without first un-

mapping the original volume from the server because the LVM UUID will conflict due to being the same.

There are two different options to recover data or virtual machines using Dell Compellent Replays.

Recovery Option 1 – One VM per LUN The first option is the easiest way to recover however it also requires more administration of LUNs.

This recovery option utilizes a 1:1 ratio of virtual machines to LUNs on the Dell Compellent SAN. This

option allows for easy recovery of volumes/virtual machines to the XenServer by creating a local

recovery view of the Volume in Storage Center.

Prior to mapping the Replay to the XenServer(s) remove the mapping to the original volume. Since the

Replay has the same UUID as the original volume, XenServer will reattach to the volume just as if it

was the original.

The following process details how to recover a virtual machine to a previous state using the 1:1

mapping of Virtual Machines to LUNs.

The Dell Compellent System does not limit the number of LUNs that can be created, however the

servers HBA usually have a limitation of 256 LUNs per server.

Recovery Scenario

• XenServer Pool containing two servers, XenServer6P1S1 and XenServer6P1S2.

• All servers are connected to the Dell Compellent Storage Center using Fibre Channel and zoned accordingly.

• The Dell Compellent Storage System has been setup to take hourly Replays of the volume running one virtual machine named W2k8-Xen6.

1. As shown below, a volume is created on the Dell Compellent system and named Xen6_P1_SR2. Also note the replay of this volume created at 08:30:00 PM.

Replays can be manually or automatically generated on the Compellent system by utilizing the Replay

Scheduler or manually through the Storage Center Console.

Page 41: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 41

Figure 42, Compellent Replays

2. The figure below depicts the VM named w2k3-xen5 running.

Figure 43, W2k8-Xen6 Online

In this example a catastrophe strikes w2k8-xen6 rendering it unbootable. By using Dell Compellent Replays the server can be quickly recovered to the time of the last snapshot.

Page 42: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 42

3. Verify the VM is shutdown in the XenServer Console. 4. Highlight the Xen6_P1_SR2 volume hosting w2k3-xen5 and select Forget Storage Repository to

remove this volume from the XenServer Pool. Figure 44, Forget SR

5. Go to the Dell Compellent Storage Center Console and highlight the volume containing the VM. In this example this is the Xen6_P1_SR2 volume.

6. Select the Mapping button. Figure 45, Volume Mapping

7. Note the LUN number for the mapping. 8. Highlight each of the mappings listed individually and select the Remove Mapping button. 9. Select Yes on the Are you sure screen. 10. Select Yes (Remove Now) on the Warnings screen. 11. Repeat until all mappings are removed from the volume.

Page 43: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 43

Figure 46, Remove Mappings

12. With the volume in question selected from the Dell Compellent Storage Center console, click the Replays button. Right click on the replay to recover to and select Create Volume from Replay. In this example it is the replay dated 09/10/2011 08:30:00 pm.

Figure 47, Local Recovery

13. On the Create Volume from Replay screen enter an appropriate name for the Replay Volume and select the Create Now button.

14. On the Map Volume to Server screen select one of the appropriate servers in the pool to map the view volume to, and then select Continue.

15. Go to the Advanced options screen enter the appropriate LUN number then select Continue. In this example LUN 2 is being used as that was the original volume number.

16. When completed select Create Now. 17. This procedure only mapped the volume to one server, if more mappings are required select

the Mappings button and add the appropriate mappings to the volume to represent all the

Page 44: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 44

servers in the XenServer Pool. In the example below the server XenServer6P1S1 and XenServer6P1S2 are both added to the new View Volume.

Figure 48, Volume Mappings

18. Return to the XenCenter console, right click on the pool and select New Storage Repository.

Figure 49, New SR

19. Select the appropriate type of storage for the volume then select Next. In this example it is a FC connection so hardware HBA should be selected.

Page 45: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 45

Figure 50, SR Type

20. On the Select the LUN to reattach or create a new SR on screen select the appropriate volume, name it accordingly, then select Finish.

Figure 51, Select LUN

21. A message should appear asking if the SR should be Reattached, Formatted or canceled. Select

Reattach.

Page 46: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 46

Figure 52, Reattach SR

22. With the replay of the SR now attached to the Pool, the virtual disk can be mapped to the virtual machine. From XenCenter highlight the server to be recovered then select the Storage Tab. Notice that the server doesn’t have a disks associated with it.

23. Click the Attach button to associate a disk to the VM.

Figure 53, Attach Disk

24. Expand the recovered SR, select the appropriate disk and click Attach.

Page 47: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 47

Figure 54, Select Disk

25. The Virtual machine can now be started in the same state it was in at the time of the last

Replay. In this example the last Replay was taken at 8:30 pm.

Figure 55, Start VM

26. If satisfied with the result the original volume can be coalesced into the new view volume by

following the remaining steps.

CAUTION: Continuing the original volume with the view volume will destroy the original volume.

27. Highlight the original volume, right click on it and choose delete.

Page 48: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 48

Figure 56, Delete Volume

28. Confirm the action by clicking Yes to move the volume to the Recycle Bin. 29. To completely remove the volume from the system, delete the volume from the recycle bin by

expanding the recycle bin, right click on the volume and choose delete. Figure 57, Delete Volume from Recycle Bin

30. Confirm the delete by clicking Yes. 31. The original volume is not removed leaving the recovery volume as the primary volume. Once

the associated replays of the view volume are expired they will be coalesced into the volume as shown below.

Page 49: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 49

Figure 58, Volume with Replays Associated

Figure 59, Replay Coalescing

Page 50: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 50

Figure 60, Coalescing Complete

Recovery Option 2 – Recovery Server The second option available for recovering virtual machines with Dell Compellent Replays is using a

standalone recovery XenServer. This option is useful when multiple virtual machines are hosted on

each SR as it allows recovery of one VM to a recovery server utilizing Dell Compellent Replays.

As mentioned earlier, there is a limitation that prevents mounting the replay to the same XenServer or

Pool due to the UUID associated with the disks will conflict. Adding a separate standalone XenServer

recovery server allows administrators to map the recovery volume to the recovery server and attach

the SR. A new virtual machine can then be created and mapped to the appropriate virtual disk. The

recovered virtual machines can then be exported and imported back into the production system.

Below is a step by step guide on recovering virtual machines to a standalone XenServer or a Remote DR

site XenServer.

Recovery Scenario

• XenServer Pool containing two servers, XenServer6P1S1 and XenServer6P1S2.

• Standalone (Recovery) XenServer named XenRecovery.

• All servers are connected to the Dell Compellent Storage Center using Fibre Channel and are already zoned accordingly.

• A replay is created on the volume Xen6_P1_SR2.

1. From the Dell Compellent Storage Center console, select the volume to recover and click the Replays Button.

Page 51: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 51

Figure 61, Volume Replays

2. Right click on the replay to recover to and select Create Volume from Replay. In the example below the Replay used is dated 09/11/2011 08:09:54 am.

Figure 62, Local Recovery

3. On the Create Volume from Replay screen enter an appropriate name for the Replay volume and click the Create Now button.

4. On the Select a Server to Map screen select one of the recovery servers to map the view volume to, click Continue.

5. In the Map Volume to Server Advanced options, enter the appropriate LUN numbers for the server port. If mapping to multiple servers set each mapping to the same LUN number. In the example LUN 12 is used. Click Create Now.

When mapping to multiple servers in a Pool use the Storage Center Cluster Server Object. This will create the mapping to all servers with the same LUN number.

Page 52: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 52

Figure 63, LUN Number

6. The next step after mapping the storage to the recovery XenServer is to add the Storage

Repository to the recovery server. A separate copy of XenCenter must be used or the original Pool must first be removed from the

console. XenCenter will not allow the addition of this Storage Repository to the recovery server if it

sees that volume mapped elsewhere.

Page 53: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 53

Figure 64, XenCenter Console

7. From XenCenter right click on recovery XenServer and select New Storage Repository.

Figure 65, New SR

Page 54: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 54

8. Select the appropriate storage type and click Next.

Figure 66, Select Disk Type

9. Enter a name for the new SR and click Next.

Figure 67, Enter SR Name

10. Select the recovered LUN, name it, and click Finish.

Page 55: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 55

Figure 68, Select Recovery LUN

11. A warning message should appear stating that an existing SR was found on the selected LUN.

click Reattach.

Figure 69, Reattach SR

12. Now that the SR has been added to the recovery server the process of recovering the VMs can

be started. The next step is to create a new virtual machine as a placeholder. 13. Right click on the recovery XenServer and choose New VM.

Page 56: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 56

Figure 70, New Virtual Machine

14. Select the appropriate template for the server then click Next.

Figure 71, OS Template

15. Enter in a name for the server then click Next. Typically the actual server name of the VM being recovered is used.

Page 57: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 57

Figure 72, Virtual Machine Name

16. Click Next on the Locate the operating system installation media screen.

Figure 73, Installation Media

17. Click Next at Select a home server screen.

Page 58: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 58

Figure 74, Select VM Home Server

18. Enter in the appropriate amount of vCPUs and Memory then click Next.

Figure 75, Size CPU and Memory

19. On the screen Enter the information about the virtual disks for the new virtual machine, select a location to store a temporary virtual disk, then click Next. Typically it is best to store the temporary disk on a SR that isn’t being used for recovery.

Page 59: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 59

Figure 76, Temporary SR Disk Location

20. On the Add or remove virtual network interfaces screen click Add, select the appropriate network, then click Next.

Figure 77, Select Network

21. On the Virtual machine configuration is complete screen uncheck Start VM automatically and click Finish.

Page 60: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 60

Figure 78, Uncheck Start VM Automatically

22. From the XenCenter Console select the newly create VM then select the Storage tab. 23. Highlight the virtual disk temporarily attached to the VM and select Delete or Detach. Since

this disk contains no information it is OK to delete it.

Figure 79, Detach Disk

24. Click Yes at the Delete system disk message.

Page 61: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 61

Figure 80, Delete System Disk

25. Once the temporary disk is deleted click the Attach button to select the original disk from the recovered Volume. Expand the recovered LUN and select the appropriate disk to attach.

Figure 81, Attach Disk

NOTE: If there are multiple disks in the Storage Repository with no name, it may take some trial

and error to connect to the correct disk. Use the Storage Tab to detach and reattach disks until

the correct one is selected. Restoring the MetaDate will prevent this issue. If a Virtual Machine

MetaData backup has been taken on the Volume, use the procedure outlined in the “VM MetaData

Back and Recovery” section to recover the names.

From this point the VM can be started, exported, copied etc. Typically the VM would be exported and

imported back into the production Pool.

Page 62: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 62

Dynamic Capacity

Dynamic Capacity Overview

Dell Compellent's Thin Provisioning, called Dynamic Capacity, delivers the highest storage utilization

possible by eliminating allocated but unused capacity. Dynamic Capacity completely separates storage

allocation from utilization, enabling users to allocate any size virtual volume upfront yet only consume

actual physical capacity when data is written by the application.

Dynamic Capacity with XenServer

When XenServer is connected to Dell Compellent storage via iSCSI or Fibre Channel connections the

Storage Repository is created as a LVM (Linux Volume Manager) repository. When the volume is created

on the Dell Compellent System by default the newly created volume consumes zero space. Only when

data is written to the volume will space be acquired and only the written space is consumed.

Page 63: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 63

Data Progression

Data Progression on XenServer

The foundation of Dell Compellent’s Automated Tiered Storage patent is our unique Dynamic Block

Architecture. Storage Center records and tracks specific information about blocks of data, including

time written, time accessed, frequency of access, associated volume, RAID level, and more. Data

Progression utilizes all of this metadata, or “data about the data” to automatically migrate blocks of

data to the optimum storage tier based on usage and performance, unlike traditional systems that

move entire files.

Figure 82, Data Progression

Data Progression automatically classifies and migrates data to the optimum tier of storage, retaining

frequently accessed data on high performance storage and storing infrequently accessed data on lower

cost storage.

XenServer, like other virtualization hypervisors, will contain virtual machines running Windows, Linux,

or other virtual machines that contain stagnant data, data that is read frequently and heavy read/write

data such as transaction logs and pagefiles.

Take a Virtual Machine running a file server for example. A user copies a new file to the file server.

The Dell Compellent system writes the data instantly to Tier 1 Raid 10. The longer the file sits without

any reads/writes, the further the blocks of data that make up the file will transition in the tiering

structure until it reaches Tier 3, Raid 5. Typically less than 20% of data on the file server is accessed

frequently. The Dell Compellent system is optimized to automatically move this data between tiers

without any assistance. In a typical storage solution, an Administrator would have to manually move

files from one Tier to another. This equates to costs savings by storing static data on low-cost, high-

capacity disks and by eliminating the need to manage data manually. Only data that is required to be

on Tier 1 Storage will remain on that Tier.

Page 64: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 64

Boot from SAN In some cases, such as with blade servers that do not have internal disk drives, booting from SAN is the

only option, but a lot of XenServers have internal mirrored drives giving administrators the flexibility to

choose whether to boot from SAN or local disks.

Booting from SAN allows administrators to take Replays of the boot volume, replicate it to a DR site,

and provides for fast recovery to other identical hardware if that XenServer fails. However, there are

also benefits to booting from local disks and having the virtual machines located on SAN resources.

Since it only takes about 30 minutes to install and patch a XenServer, booting from local disks insures

the server will stay online if there is a need to do maintenance to fibre channel switches, Ethernet

switches, or the SAN itself. The other advantage of booting from local disks is that this configuration

does not require iSCSI or FC HBAs. The XenServer can boot from local disk and use the iSCSI software

initiator to connect to shared storage on the SAN.

Page 65: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 65

VM Metadata Backup and Recovery The metadata for a VM contains information about the VM (such as the name, description, and

Universally Unique Identifier (UUID)), VM configuration (such as the amount of virtual memory and the

number of virtual CPUs), and information about the use of resources on the host or Resource Pool (such

as Virtual Networks, Storage Repository, ISO Library, and so on).

Most metadata configuration data is written when the VM is created and is updated when changes to

the VM configuration are made. Adding a metadata export command to the change-control checklist

will ensure that this information is available if needed.

NOTE: Without the Metadata Backup the names and descriptions of files on the SR may not be available

for a recovery. This will make recovery a difficult process.

Figure 83, Conceptual Overview of XenServer Disaster Recovery

Backing Up VM MetaData In XenServer, exporting or importing metadata can be done from the text-based console menu. On the

physical console the menu is loaded by default. To start the console menu through the host console

screen in XenCenter, type: xsconsole from the command line.

Page 66: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 66

Figure 84 Backup, Restore and Update Screen

To export the VM metadata:

1. Select Backup, Restore and Update from the menu. 2. Select Backup Virtual Machine Metadata. 3. If prompted, log on with root credentials. 4. Select the Storage Repository where the desired VMs are stored. 5. After the metadata backup is done, verify the successful completion on the summary screen. 6. In XenCenter, on the Storage tab of the SR selected in step 4, a new VDI should be created

named Pool Metadata Backup.

Figure 85 Backup Summary Screen

Page 67: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 67

Another option available from the console menu is Schedule Virtual Machine Metadata. This option

allows for automated exports of metadata on a daily, weekly, or monthly basis. By default this option

is disabled.

Importing VM MetaData A prerequisite for running the import command in a DR environment is that Storage Repository(s)

(where the replicated virtual disk images are located) need to be setup and re-attached to a

XenServer. Also make sure that the Virtual Networks are set up correctly by using the same names in

the production and DR environment.

After the SR is attached, the metadata backup can be restored.

From the console menu:

1. Select Backup, Restore and Update from the menu.

2. Select Restore Virtual Machine Metadata.

3. If prompted, log on with root credentials.

4. Select the Storage Repository to restore from.

5. Select the Metadata Backup you want to restore.

6. Select restore only VMs on this SR or all VMs in the pool.

7. After the metadata restore is done, verify the summary screen and check for errors.

8. The VMs are now available in XenCenter and can be started at the new site.

Figure 86 Metadata Restore Summary

Page 68: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 68

Disaster Recovery XenServer 6 provides the enterprise with functionality designed to recover data from a catastrophic

failure of hardware which disables or destroys a whole pool or site. The XenServer 6 Disaster Recovery

feature provides the mechanism to backup services and applications while Dell Compellent replication

technology provides a means to make this data available at a remote site. Together they provide a

high availability solution for mission critical services and applications

This functionality is extended with XenServer Virtual Appliance (vApp) technology. A vApp is a logical

group of one or more related VMs which can be started as a single entity in the event of a disaster.

When a vApp is started, the VMs contained within the vApp are started based on a predefined order,

relieving the administrator from manually stating servers. The vApp functionality is useful in DR

situation where all VMs in s vApp reside on the same Storage Repository.

NOTE: XenServer Disaster Recovery can only be enabled when using LVM over FC/iSCSI HBA, or software

iSCSI. A small amount of space will be required on the storage for a new LUN which will contain the

pool recovery information.

Replication Overview XenServer Disaster Recovery takes advantage of Dell Compellent’s replication technology to provide

high availability. Dell Compellent replicates volumes in one direction. In a DR scenario, data is

replicated from the primary site to the secondary site. By default, Dell Compellent replication is not

bidirectional; therefore it is not possible to XenMotion between source Storage Center (the primary

site) and destination Storage Center (the secondary site) unless using Dell Compellent Live Volumes for

Replication. The following best practices recommendations for replication and remote recovery should

be considered.

• Compatible XenServer server hardware and OS is required at the DR site to map replicated

volumes to in the event the main XenServer Pool becomes inoperable.

• Since replicated volumes can contain more than one virtual machine, it is recommended to sort

virtual machines into specific replicated and non-replicated Storage Repositories. For example,

if there are 30 virtual machines in the XenServer Pool, and only eight of them need to be

replicated to the DR site, a special "Replicated" volume should be created to place those eight

virtual machines on, or utilize a 1:1 mapping of VMs to Volumes and only replicated the

required VMs.

• Take advantage of the Storage Center QOS settings to prioritize the replication bandwidth of

certain "mission critical" volumes. For example, two QOS definitions could be created so that

the "mission critical" volume would get 80 Mb of the bandwidth, and the lower priority volume

would get 20 Mb of the bandwidth.

The following steps should be taken in preparation for a disaster:

• Configure the VMs and vApps.

• Note how the VMs and vApps are mapped to the SRs and the SRs to Volumes. Verify that the

name_label and name__description are meaningful and will allow an administrator to

recognize the SR after a disaster.

• Configure replication of the SR volume

Page 69: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 69

After the VM and vApps have been configured the Volumes can be replicate to the secondary DR site.

This process is simplified with Dell Compellent Enterprise Manager (EM) GUI. In the example below, an

SR Volume that resides on a Storage Center named SC13 at the primary location is replicated to a

Storage Center named SC12 at the secondary location. The Dell Compellent Enterprise Manager User

Guide outlines the steps necessary to configure replication.

Figure 87 Enterprise Manager Replication

Disaster recovery can be configured once replication is setup and all data has been replicated to the

secondary site. Follow the steps below to configure Disaster Recovery

NOTE: The examples below server as a reference for the requirements of configuring XenServer DR with

Dell Compellent Storage Center. For complete information on configuring and testing XenDesktop DR

consult the Citrix XenServer 6.0 Administrators Guide.

1. Select the pool at the primary site that will be protected and go to the Pool menu, Disaster

Recovery, and select Configure. This will open the DR configuration window.

Figure 88, Select DR Pool

2. Select the Storage Repositories that will be protected with XenServer DR and click OK to finish.

Page 70: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 70

XenServer DR is now configured on the volume and ready to be tested.

Test XenServer Disaster Recovery

The process bellow will test the configuration of XenDesktop DR, replication and configuration of the

Pool at the secondary site. The process will use a Storage Center View Volume for testing. The View

Volume will be created at the secondary site and mapped to that pool for the DR test. The use of View

Volumes will allow the test to be performed without interrupting replication between the two sites.

The steps below outline the process of testing XenServer DR with Dell Compellent:

NOTE: Be sure the most recent information, including a Replay taken after DR was configured, has

been replicated to the secondary site before testing DR failover.

1. Create a View Volume of the replicated volume at the secondary site by right clicking on the most

recent Replay and selecting Create Volume from Replay.

Figure 89 Create View Volume for DR Test

2. Next, map the new View Volume to the servers in the recovery pool.

3. After the View Volume has been created and mapped, run the Disaster Recovery Wizard by

selecting the recovery pool in XenCenter going to Pool, Disaster Recovery, and selecting Disaster

Recovery Wizard.

4. On the Disaster Recovery Wizard window select Test Failover and click on Next.

Page 71: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 71

Figure 90 Disaster Recovery Failover Test

5. Read the message on the Before You Start screen and click Next to reach the Locate Mirrored SRs

screen. From the Find Storage Repositories dropdown box, select the type of mappings used to

connect the servers in the Pool to the View Volume, either HBA or software iSCSI.

NOTE: Only iSCSI and FC HBAs and Software iSCSI are available for the XenServer DR feature.

Figure 91, Locate Mirrored SR

6. Select the SR to test and click Next to continue. XenServer will mount the SR and discover the VMs

and vApps on the volume.

7. On the next screen, select the VMs and vApps to be tested. Also select the desired option for the

power state after the recovery. Click Next to continue.

Page 72: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 72

Figure 92 Select VMs and vApps to test

8. The Disaster Recovery Wizard will check prerequisites on the next screen. Once the failover

pre-checks are finished, click the Fail Over button to continue the test. The test may take

some time depending on the number of VMs involved. During this time, the VMs and vApps that

were selected in the previous step will be created in the secondary Pool and started if that

option was selected.

Figure 93 Failover Test Progress

9. The progress screen will show the status of the DR process.

10. Clicking Next will display the summary of the test. Also, the VMs and vApps will be removed

from the Pool as well as the replicated volume.

11. Clicking Finish at the Summary of Test Failover screen will conclude the test.

Page 73: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 73

Recovering from a Disaster The steps to recover from a disaster are similar to testing a failover with a few exceptions. Below are

the steps to take when recovering from a disaster

• Break replication between the primary and secondary site

• Shut down the VMs and vApps at the primary site if they are still running

• Ensure that the recovery volume at the secondary sit is not attached to any other pool. If the

volume is attached to multiple pools data corruption may occur.

There are two options to prepare the volume at the secondary Storage Center for a failover. The first

option is to create and map a View Volume to the servers in the recovery pool. This is the same

process as outlined in the failover test above and is the preferred method for recovering from a

disaster.

The second option is to remove replication and mount the replicated volume. This can be done by

removing the replication in Enterprise Manager and adding mappings to the servers in the recovery pool

at the secondary site.

1. To remove replication, go to Replications in EM and select the source Storage Center.

2. Right Click on the volume and select Delete. This will bring up the Delete Replication screen.

Figure 94 Delete Replication in EM

3. Be sure that “Put Destination Volume in the Recycle Bin” is NOT selected and click OK.

4. Alternatively, if the Storage Center at the source site is not available, the source Storage Center

mappings can be removed from the “Mapping” tab under the destination volumes properties. This

will prevent replication to the volume if the source comes back online.

Page 74: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 74

Figure 95 Remove Source Mapping

Once the replication has stopped the volume at the secondary site can be mapped to the servers in the

recovery pool.

1. To begin the failover process, select the recovery pool and go to Pool, Disaster Recovery Wizard

and select Failover on the Welcome screen.

Figure 96, Disaster Recovery Failover

2. Click Next on the Before you start screen and use the Find Storage Repositories dropdown to

locate the recovery SR that was mapped to the servers in a previous step. Repeated this process for

each SR to be recovered. Click Next when finished.

Page 75: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 75

Figure 97, Select Mirrored SR

3. Select the VM’s and vApps that are to be recovered. Select the appropriate Power State after

Recovery option and click Next.

Figure 98, Select vApps and VMs to Fail Over

Page 76: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 76

4. Resolve any pre-check errors and click Fail Over to begin the failover process. This may take some

time depending on the number of VMs and vApps to be recovered.

Figure 99, DR Failover Progress

5. Once the DR process has completed a summary page displays the status of each vApp and VM and

its status. Click Finish to exit the wizard.

Page 77: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 77

Replication Based Disaster Recovery Citrix XenServer 6.0 introduces the new automated DR option as outlined above. This Desaster

Recovery tool is available for environments with a Platinum Software subscription only. For users

without a Platinum Software subscription there is still a semi-automated option for recovering virtual

machines at a DR site. This method leverages the Virtual Machine Metadata backup and Dell

Compellent replication to make VMs available at a recovery site. The basic steps involved include:

1. Configure replication of the protected volumes from the primary site to the secondary site.

2. Backup LUN Meta Data to each Replicated LUN.

3. Create a local recovery View volume from a Replay on the replicated XenServer SR volume.

4. Map that View Volume to the XenServer hosts(s).

5. Add Storage Repository to XenServer hosts(s).

6. Restore Virtual Machine MetaData.

Disaster Recovery Replication Example

This scenario will step through the recovery of a XenServer Pool and all its volumes on a remote DR

Server Pool. This scenario will utilize two Dell Compellent Storage Centers performing one way

replication from the source system to the destination system.

DR Environment:

Primary Site:

• Dell Compellent Storage Center SC13

• One Pool (Pool1) consisting of servers xenserver6p1s1 and xenserver6p1s2

• One FC connected Volume labeled Xen6_P1_SR1

• Virtual Machine MetaData has been backed up using the steps outlined in the VM Metadata

Backup and Recovery section

Secondary Site:

• Compellent Storage Center SC12

• One Pool (Pool2) consisting of servers xenserver6p2s1 and xenserver6p2s2

• FC connected replicated volume

The figure below shows the Pool1 Servers, data store and VM’s within the SR. Note also that the Pool

Metadata Backup exists on the SR.

Page 78: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 78

Figure 100 Primary Site Servers and SR

After the VM and vApps have been configured the Volumes can be replicate to the secondary DR site.

This process is simplified with Dell Compellent Enterprise Manager (EM). In the example below, the SR

Volume that resides on a Storage Center named SC13 at the primary location is replicated to a Storage

Center named SC12 at the secondary location. The Dell Compellent Enterprise Manager User Guide

outlines the steps necessary configure replication between the Storage Centers.

Figure 101 Enterprise Manager Replication

Next, a disaster is simulated by removing the replication jobs between the primary and secondary

Storage Center in Enterprise Manager.

1. Replication can be removed in Enterprise Manager by going to Replications and selecting the

source Storage Center. This will list the replications from that Storage Center.

2. Right Click on the volume and select delete. This will bring up the delete replication screen.

Be sure that “Put Destination Volume in the Recycle Bin” is NOT selected and click OK.

Page 79: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 79

Figure 102 Delete Replication in EM

NOTE: A disaster test could have been done by simply creating a View Volume from one of the replays

on the DR Storage Center system. This process would allow the testing of a DR plan to validate data at

any time without disrupting replication

3. Next, the servers at the secondary site are mapped to the volume. In this example, servers

XenServer6P2S1 and XenServer6P2S2 are mapped to the volume “Repl of Xen6_P1_SR1”.

Figure 103, Server Mapping to the Recovery Volume

4. After the volume is mapped to the servers in pool2 at the secondary site it can be attached

using the New Storage Wizard in XenCenter. The figure below shows the storage attached to

the secondary pool. The VM files are on the storage but not yet available in the pool.

Page 80: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 80

Figure 104, Recovery Pool

5. To add the VMs to the recovery pool the Metadata will need to be restored using the XenServer

Console Backup, Restore and Update menu. It is important that the VM networks are named

exactly the same in order for this to succeed.

Figure 105, VM Metadata Restored

6. After the Metadata is restored the VM’s will be available at the secondary site. Once the

Virtual Machine MetaData is restored, the Virtual machines can be started on the remote DR

XenServer.

Page 81: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 81

Figure 106, Recovered VMs

After the recovery to the secondary site it may be necessary to fail back to the primary site. The

failback process is the same as outlined above, except for modifying the primary and secondary site to

reflect the VMs source and destination location.

Page 82: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 82

Live Volume

Overview Live Volume is a software option for Compellent Storage Center that builds upon the Fluid Data

architecture. Live Volume enables non-disruptive data access and migration of data between two

Storage Centers.

Figure 107, Live Volume Overview

Live Volume is a software-based solution integrated into the Dell Compellent Storage Center

controllers. Live Volume is designed to operate in a production environment, allowing both Storage

Centers to remain operational during volume migrations.

Live Volume increases operational efficiency, reduces planned outages, and enables a site to avoid

disruption during anticipated disasters. Live Volume provides these powerful new options:

• Storage Follows the Application in Virtualized Server Environments. Live Volume automatically migrates data as virtual applications are moved.

• Zero Downtime Maintenance for Planned Outages. Live Volume enables all data to be moved non-disruptively between Storage Centers, enabling full planned site shutdown without downtime.

• On-demand Load Balancing. Live Volume enables data to be relocated as desired to distribute workload between Storage Centers.

• Stretch Microsoft, VMware, and XenServer Volumes between geographically disperse locations. Live Volume allows servers to see the same disk signature on the volume between datacenters thereby allowing the volume to be clustered.

Page 83: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 83

Live Volume is designed to fit into existing physical and virtual environments without disruption and

without requiring extra hardware or changes to configurations or workflow. Physical and virtual servers

see a consistent, unchanging virtual volume. All volume mapping is consistent and transparent before,

during, and after migration. Live Volume can be run automatically or manually and is fully integrated

into the Storage Center software environment. Live Volume operates asynchronously and is designed

for planned migrations where both Storage Centers are simultaneously available.

A Live Volume can be created between two Dell Compellent Storage Centers residing in the same

datacenter or between two well-connected datacenters.

Using Dell Compellent Enterprise Manager, a Live Volume can be created from a new volume, an

existing volume, or an existing replication. For more information on creating Live Volume, see the

Compellent Enterprise Manager User Guide.

For more information on the Best Practices for Live Volume please see the Dell Compellent Storage

Center Best Practices Document for Live Volume on the Dell Compellent Knowledge Center Portal at

http://kc.compelent.com .

Page 84: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 84

Appendix 1 Troubleshooting

XenServer Pool FC Mapping Issue Occasionally when connecting a FC Volume to a XenServer Pool is the mapping is only made on the

Master node in the pool and is not connected on the additional nodes. This typically takes place if

attempting to attach the Volume right after the creation of the Volume. In most instances, waiting

approximately one hour before mapping the volume will prevent this issue from occuring.

The following section details the steps necessary to fix the missing connection issue when mapping a

New SR to a XenServer pool without rebooting the hosts or moving the Master.

Notice in the figure below that the SR mapped to Pool1 is mapped correctly to the host server

XenServer6P1S1 but not to the server XenServer6P1S2.

Figure 108, SR Mapping Broken

To resolve this issue logon to the console of one of the XenServers in the pool and go to the local

command shell. This can be done either from the console or from a SSH client such as PuTTy.

At the command prompt type: xe host-list to obtain the list of all the server in the pool and their

associated UUIDs. [root@ XenServer6P1S1 ~]# xe host-list

uuid ( RO) : 5cd5d2ed-b462-4eba-9761-d874b8e3e564

name-label ( RW): XenServer6P1S 1.techsol.local

name-description ( RO): Default install of XenServer

uuid ( RO) : be925e21-a95e-438d-8155-b98d09c26351

name-label ( RW): XenServer6P1S 2.techsol.local

name-description ( RO): Default install of XenServer

[root@ XenServer6P1S1 ~]#

1. Run the SR-Probe command for each of the XenServer hosts not mapping the volume correctly.

Type the following to probe the host: xe sr-probe host-uuid=<uuid or server> type=lvmohba

Page 85: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 85

[root@ XenServer6P1S1 ~]# xe sr-probe host-uuid=5cd5d2ed-b462-4eba-9761-d874b8e3e564 type=lvmohba

7. Once the sr-probe command has been completed for all the hosts the SR can be repaired by

right clicking the SR from the XenCenter console and selecting Repair Storage Repository.

Figure 109, Repair Storage Repositories

2. Click the Repair button. 3. When the repair is complete all nodes should report back as Connected.

Figure 110, Repaired SR

Starting Software iSCSI Software iSCSI may need to be started manually when iSCSI commands are ran on the server and the

following errors occur:

Page 86: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 86

Cannot perform discovery. Initiatorname required

or

iscsid is not running. Could not start up automatically using the startup command….

Two ways to Start iSCSI

1. Through the GUI:

The process of adding storage with XenCenter will start iSCSI on the server. Go to XenCenter,

Select the host and go to New storage> Software iSCSI> Enter control port in target host>

discover IQN’s, Discover LUNs. The step “Discover LUNs” will start iSCSI on the host. Cancel

out of the Add Storage Wizard to quit without making changes.

2. Through the Command Line:

Start the iSCSI service:

service open-iscsi start

Run sr-probe:

xe sr-probe type=lvmoiscsi device-config:target=x.x.x.x

where x.x.x.x is the Storage Center Control Port

Software iSCSI Fails to Start as Server Boot See Citrix Document CTX122852 to configure auto start. These steps should to be run after iSCSI has

been started and has scanned the Storage Center. Scanning the Storage Center will create the node

IQN files referenced in the Citrix Document on the server.

Wildcard Doesn’t Return All Volumes When adding storage using the wildcard option, an incomplete list of Volumes mapped to the server

may be returned. In this situation, XenCenter only scans the first IP address listed in the Target Host

field, resulting in a an incomplete listing of Target LUNS. This is a know issue with the XenCenter GUI.

To work around, cycle through the Storage Center Control Ports in the Target Host field. Be sure to

always use the (*) Wildcard Target IQN when discovering LUNs. This is a GUI issue and will not affect

multipathing.

Caution: Issues have been identified with the Citrix implementation of multipathing and Storage

Center in virtual port mode. It is strongly recommended to use iSCSI HBAs when implementing

XenServer with Storage Center in virtual port mode.

Page 87: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 87

Figure 111 Finding Target LUNs

View Multipath Status Use the iSCSIadm -m session command to view the active software iSCSI sessions on the server.

Use mpathutil status command to view the status of multipathing

If only one path is showing in a multipath environment, typically after a reboot

Figure 112, Multipath Issue

Run the iscsiadm -m node --login command to force the iSCSI software initiator to connect both

paths

Figure 113, Multipath Active

Following the steps outlined in Citrix Document CTX122852 may resolve this issue.

XenCenter GUI displays Multipathing Incorrectly If the GUI does not display multipathing information correctly, cycle the multipath server with this

command:

Service multipathd restart

Next, run the Python script to update XenCenter

/opt/xensource/sm/mpathcount.py

Page 88: Dell Compellent Storage Center - UNAM...Capacity, Data Progression, Replays, and Remote Instant Replay. This document focuses on XenServer 6.0, however most of the concepts apply to

Dell Compellent Storage Center XenServer 6.x Best Practices

Page 88

Connectivity issues with a Fibre Channel Storage Repository If there are issues with a Fibre Chanel SR, first identify the host UUID with this command

xe host-list

Next, probe the SR using this command

xe sr-probe host-uuid=<uuid of server> type=lvmohba

Go into XenCenter and select the server. Right click on the SR and select the Repair Storage

Repository Option

Figure 114, Repair Storage Repository