Tanks 502Dosing tank
GRUNDFOS ALLDOS INSTRUCTIONS
Installation and operating instructions
2
CONTENTSpage
1. General notes 31.1 Service documentation 32. Installation data 43. Installation sketch 44. Intended purpose 54.1 Guarantee 55. Safety 55.1 Identification of safety notices in this manual 55.2 Qualification and training of staff 55.3 Risks when safety notices are not observed 55.4 Safety-conscious working 55.5 Safety notices on inspection and installation work 55.6 Unauthorised conversions and impermissible
spare parts 55.7 Incorrect operation 56. Description of product and accessories 56.1 General description 56.2 Technical data 66.2.1 Weight 66.3 Tank versions 66.4 Product numbers 76.5 Fitted tank dosing station 86.6 Installing dosing pump and agitator 96.7 Dimensional drawings 107. Transport and storage 127.1 Unpacking 127.2 Storage 128. Installation 128.1 General notes 128.2 Tightness test 129. Commissioning and operation 1210. Maintenance 1211. Accessories 1211.1 Drip trays 1211.2 Adapter plate 1211.3 PVC handheld mixer 1211.4 Electric agitators 1211.5 Side extraction device 1311.6 Drain valve R 3/4" 1411.7 Aeration / ventilation valve for dosing tank 1411.8 Filling unit 1411.9 Funnel release device 1412. Disposal 14
1. General notesThese installation and operating instructions contain all the information needed to commission and operate the dosing tank 502 listed below.If you require further information or should problems arise which are not described in detail in this manual, please contact your nearest Grundfos Alldos branch.
1.1 Service documentationIf you have any other questions, please contact your nearest Grundfos Alldos branch.
WarningThese installation and operating instructions are also available online at www.Grundfosalldos.com.Please read these installation and operating instructions before installation. Installation and operation must be undertaken in accordance with local regulations and the rules of technology.
3
2. Installation data
Owner:
Grundfos Alldos customer no.:
Contract no.:
Order no.:
Serial no.:
Commissioning on:
Installation site:
Used for:
3. Installation sketch
Note
Please enter the following data after commissioning. It will help you and your Grundfos Alldos service partner to undertake settings on the installation later on.
4
4. Intended purposeDosing tanks from Grundfos Alldos, series 502, are intended as supply bottles for dosing media for dosing chemicals as described in these instructions.
4.1 GuaranteeIn line with our general conditions of sale and delivery, a guarantee claim can only be recognised if:• the dosing tank was only used as described in the
corresponding instructions.
5. SafetyThese instructions contain general information which should be observed when installing and operating the dosing tank. These instructions must therefore be read with care by technicians and appropriately trained specialists/operators before installation and commissioning and must always be available at the installation site.It is not only the general safety notices described in this "Safety" section that must be observed, but all specific safety notices that are provided in the other sections too.
5.1 Identification of safety notices in this manualIf the safety notices or other information provided in these instructions are not observed, this may result in injury and the dosing tank may be damaged. Safety notices and other information are identified by the following symbols:
Information on the dosing tank must be clearly legible at all times.
5.2 Qualification and training of staffThe staff responsible for operation, inspection and installation must be suitably qualified for this work. Areas of responsibility, levels of responsibility and staff supervision must be precisely defined by the person responsible for operations.If staff do not have the necessary knowledge, they should be trained and instructed accordingly. The person responsible for operations is in charge of ensuring that the staff understand the content of these instructions.
5.3 Risks when safety notices are not observedNon-observance of the safety notices may have dangerous consequences for staff, the environment and the pump. Non-observance of the safety notices may lead to the loss of any claims for damages.Non-observance of the safety notices may lead to the following risks:• failure of important functions of the system• personal injury caused by electrical, mechanical and chemical
influences• environmental damage due to media hazardous to health
escaping.
5.4 Safety-conscious workingThe safety notices in these instructions should be observed in the same way as statutory health and safety at work guidelines and the operating and safety notices provided by the person responsible for operations.
5.5 Safety notices on inspection and installation workThe person responsible for operations must ensure that all installation and inspection work is undertaken by authorised specialists who are appropriately trained by reading these instructions.All safety and protection equipment must be put back into operation as soon as work is complete.
5.6 Unauthorised conversions and impermissible spare parts
Modifications or changes to the dosing tank are only permitted with the consent of the manufacturer. Genuine spare parts and accessories approved by the manufacturer are safe to use.Liability cannot be assumed if spare parts which are not genuine are used.
5.7 Incorrect operationThe operating safety of the dosing tank supplied is only ensured if it is used in compliance with section 6.2 Technical data. The specified limit values should on no account be exceeded.
6. Description of product and accessories
6.1 General descriptionDosing tank 502 can be used as a supply bottle for dosing media. It is compact, resistant to chemicals, simple and therefore low cost. Depending on the model, the dosing tank can be fitted with a dosing pump, suction lance and agitator to form a dosing station. The dosing tank's characteristics are detailed below:• cylindrical tank with screw cover• optimum shape for stability and functionality• 7 sizes ranging between a content of 40 and 1000 l• UV-stabilised polyethylene (PE), food safe• produced without seams in a rotation smelting process• embossed litre scale• sintered 3/4" screw socket for drainage, not drilled open• screw cover with gating for holding a standard key lock• installation space for dosing pumps and electric agitator and/
or handheld mixer, raised above the filler opening• the 75 l, 100 l and 200 l size dosing tanks have sintered
threaded bushes for installation– of dosing pump models DDI 209, DDI 222, DMI 208 and
DMX 221– of electric agitator 509.
CautionNo other applications are approved or permitted. Grundfos Alldos is not liable for damage resulting from incorrect use.
WarningFailure to observe these safety notices may result in injury.
Caution Failure to observe these safety notices may result in malfunction and damage to property.
Note Information or instructions intended to simplify use and ensure safe operation.
WarningRepairs may only be undertaken by authorised and qualified staff.
WarningWhen dosing dangerous media, observe the corresponding safety precautions.Wear protective clothing (gloves and goggles) if required.
5
6.2 Technical data
• Permissible ambient temperature: - 40 °C to +60 °C• Permissible media temperature: -20 to +45 • Dosing medium must be in the liquid phase.• Material
– Tank: UV-stabilised medium pressure polyethylene (PE)– Gasket in screw cover: EPDM– Stopper: PE– Gasket on stopper: EPDM
6.2.1 Weight
6.3 Tank versionsSize• 40 l• 75 l• 100 l• 200 l• 300 l• 500 l• 1000 l
Colour• natural white (semi-transparent) with
– green cover, or – blue cover
• black (for media sensitive to light) with – black cover
Agitator mounting frame• 500 l and 1000 l size tanks can also be equipped with an
agitator mounting frame (reinforcement for holding an agitator).
Caution
The resistance of the parts that come into contact with media depends on the medium, media temperature and operating pressure. Ensure that parts which come into contact with media during operating conditions are resistant to the dosing medium.
Tank Weight [kg]
40 l dosing tank 3.475 l dosing tank 6100 l dosing tank 7.5200 l dosing tank 12300 l dosing tank 13500 l dosing tank 24500 l with agitator mounting frame 281000 l dosing tank 401000 l with agitator mounting frame 48
6
6.4 Product numbers
Product number Content[l]
ColourEquipment
Tank Cover
96688081 (502-0040) 40 transparent green96726826 (502-0040.2) 40 transparent blue95701166 (502-0040.3) 40 black black96688082 (502-0075.1) 75 transparent green96688083 (502-0075.2) 75 transparent blue95713034 (502-0075.3) 75 black black91836501 (502-0100.1) 100 transparent green96295840 (502-0100.2) 100 transparent blue95704924 (502-0100.3) 100 black black96690348 (502-0200.1) 200 transparent green96295841 (502-0200.2) 200 transparent blue95702114 (502-0200.3) 200 black black96688084 (502-0300.1) 300 transparent green96295842 (502-0300.2) 300 transparent blue95708393 (502-0300.3) 300 black black96690349 (502-0500.1) 500 transparent green96295843 (502-0500.2) 500 transparent blue95707976 (502-0500.3) 500 black black96688085 (502-0502.1) 500 transparent green with agitator mounting frame96295844 (502-0502.2) 500 transparent blue with agitator mounting frame95707538 (502-0502.3) 500 black black with agitator mounting frame96688086 (502-1001) 1000 transparent green96295845 (502-1001.2) 1000 transparent blue95706305 (502-1001.3) 1000 black black96689131 (502-1002.1) 1000 transparent green with agitator mounting frame96295846 (502-1002.2) 1000 transparent blue with agitator mounting frame95704476 (502-1002.3) 1000 black black with agitator mounting frame
7
6.5 Fitted tank dosing station
Fig. 1 Fitted tank dosing station (example)
TM04
123
1 50
08
Item Description
1 Tank2 Drip tray3 Agitator4 Level monitoring5 Suction line6 Injection unit (not shown)7 Pressure line8 Drain valve9 Filling unit
10 Multi-function valve11 Dosing pump
3
9
1
7
10
11
4
5
2
8
8
6.6 Installing dosing pump and agitatorThe dosing tanks are prepared for the installation of Grundfos Alldos dosing pumps and agitators as is shown below:
1)sintered threaded bushes for holding an agitator (inlet hole still needs to be drilled)
2)with agitator mounting frame for holding an agitator (inlet hole still needs to be drilled)
3)new holes need to be drilled
4)adapter plate needed
5)sintered threaded bushes for holding pump
Tank
Stan
dard
agi
tato
r
DM
S
DM
E 2-
12
DM
E 19
-48
DM
E 60
-150
DM
E 37
5-94
0
DD
I 209
DD
I 222
DM
I 208
DM
X 22
1
DM
X 22
6
DM
H 2
51 -
253
DM
H 2
54
40 l dosing tank — 3) 3) — — — 3) — 3) — — — —75 l dosing tank — 4) 4) 3) 3) 3) 5) 5) 5) 5) — 3) —100 l dosing tank 1) 4) 4) 3) 3) 3) 5) 5) 5) 5) — 3) —200 l dosing tank 1) 4) 4) 3) 3) 3) 5) 5) 5) 5) — 3) —300 l dosing tank — 3) 3) 3) 3) 3) 3) 3) 3) 3) — 3) —500 l dosing tank — 3) 3) 3) 3) 3) 3) 3) 3) 3) — 3) —500 l with agitator mounting frame 2) 3) 3) 3) 3) 3) 3) 3) 3) 3) — 3) —1000 l dosing tank — 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3)
1000 l with agitator mounting frame 2) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3)
9
6.7 Dimensional drawings
Fig. 2 40 l dosing tank
Fig. 3 75 l / 100 l dosing tank
Fig. 4 200 l dosing tank
TM04
123
3 50
08TM
04 1
234
5008
160
230
Ø210
110
490
420
350
40
Ø175
Ø185
70
45E
100
80
Ø420
M6 (4x90°)L
Ø185
Ø175
70
10
0
H
15
0
120
Ø460
45E
60105
14
06
0
105
17
4
15
9
11
3
Z
L
Z
Ø97Ø115
B (M8)
B (M6)
21
15
(85)
Ø162
TM04
123
5 50
08
B (M8)1
00
Ø185
Ø175
70
88
0
15
0
120
45E
Ø600
50
Z
Ø115
143
105 B (M6)
90
15
0
Ø162
L
110 142
10
51
5 Z
21 17
4
15
9
11
3
Ø97
10
Fig. 5 300 l dosing tank
Dimensions in mm
Fig. 6 500 l dosing tank
Fig. 7 1000 l dosing tank
TM04
123
6 50
08
Item Description
B Threaded bush, 20 mmE Drain R 3/4 "L Litre scaleZ Centring
Tank Ø D Ø d H1 H2
40 l dosing tank 420 160 420 35075 l dosing tank 460 160 630 530100 l dosing tank 460 160 790 690200 l dosing tank 600 160 880 780300 l dosing tank 670 160 1030 930500 l dosing tank 790 160 1180 10801000 l dosing tank 1080 160 1260 1150
Ø185
Ø175
70
45E
15
0
150Ø670
10
0
50
10
30
Ø6.5
105
105105
157.5
21
15
9
DMX 221
DMH 251
90
17
5
Ø160L
140 20
183
143 50
12
5
10
5
11
5
53
60°
98Ø112
Ø130
Ø9
Z
Ø8Ø70
152
TM04
123
7 50
08TM
04 1
238
5008
10
0
50
Ø185
Ø175 70
45E
15
0
150Ø790
11
80
Ø8
210
98
15
22
1
DMX 221
DMH 251
220 210
105Ø112
Ø130
Ø9
90
25
0
Ø70
Ø6.5
23
0
30
L165
Ø162
15
92
1Ø185
Ø175
E
1150
50
150
150Ø1080
1190
1260
370
230
L
350
820
11
7. Transport and storage
7.1 Unpacking• Retain the packaging for future storage or return, or dispose of
the packaging in accordance with local regulations.• Fit the dosing tank as soon as possible after unpacking.
7.2 StorageKeep the dosing tank in a dry, cool place.
8. Installation
8.1 General notes
8.2 Tightness test1. Before filling the dosing tank check whether:
– the suction line is connected, and– the optional drainage unit is fully closed.
2. Then fill the dosing tank with e.g. water and check for leaks.
9. Commissioning and operation
10. Maintenance
11. Accessories
11.1 Drip trays
11.2 Adapter plateProduct number: 96587931 (539-018)• PP adapter plate with relevant retaining bolts for DME pumps
on 75 l, 100 l and 200 l dosing tanks
11.3 PVC handheld mixerProduct number: 96295947 (520-001)• Handheld mixer, max. 1000 mm in length for mixing chemicals
in the dosing tank. The handheld mixer is suitable for 40 l - 300 l Grundfos Alldos dosing tanks.
• The length of the handheld mixer is adapted to the tank size for prefitted dosing stations before delivery. If ordered separately, the length of the handheld mixer should be adapted to the tank on site and the knob stuck on.
Fig. 8 Handheld mixer
11.4 Electric agitatorsThe agitators 509 ensure that the dosing medium in the dosing tank is mixed constantly. The 1500 rpm agitators are suitable for dosing media with a low viscosity.Grundfos Alldos agitators are available in the following versions• 7 sizes for Grundfos Alldos dosing tanks with contents of
between 75 l and 1000 l.• Plastic version: spindle PP-coated, mixer turbine made from
PP.– The annular turbine draws in the product to be mixed axially
and discharges it radially.– For outgassing media, with a sealing flange on the motor
flange• Stainless steel version for aggressive media: spindle and
mixer propeller made from stainless steel 1.4571.• Depending on agitator size, 3-phase current and optionally
single-phase motor.For more details please refer to the instructions for the electric agitators.
CautionDo not throw or drop the dosing tank.Do not use the protective packaging as packaging for transport.
WarningThe dosing tank may only be fitted by a qualified specialist.
Caution
The dosing tank is not operated. Within the system is simply serves as a supply bottle for dosing the dosing medium. When commissioning, all the system's components must be ready for operation.Follow the installation and operating instructions for the components used.
Note The dosing tank requires no maintenance.
Product no.
for
dosi
ng ta
nk
Mat
eria
l
Col
our
Dia
met
er [m
m]
Hei
ght [
mm
]
96731237(68.0170-01) 40 l PE transparent 500 545
96700572(68.0168-01) 75 l and 100 l PE black 650 540
96731303(68.0164-01) 200 l and 300 l PE black 770 960
96706323(60.2141-01) 500 l PE transparent 1150 1080
96731306(63.0610) 1000 l PE transparent 1310 900
TM04
123
9 50
08
12
11.5 Side extraction device• The PVC / FKM side extraction device can only be used on
dosing tanks without a drip tray.• Please order connections for extraction pipes separately.• The lengths of the liquid riser are adapted to the dosing tank in
question if required.• Fit the extraction device in the dosing tank's coupling thread.
– Unscrew stopper – Drill open threaded hole– Screw in extraction device and seal with Teflon tape.
• Use installation material provided to secure liquid riser to tank panel.– Cut M6 thread in tank panel– Fit screw from inside through the tank panel and counter nut
and then screw into retaining ring.– Secure from outside using counter nut.
• Seal liquid riser with stopper provided.
Fig. 9 Side extraction device DN 4 / DN 8
Fig. 10 Side extraction device DN 20
All dimensions provided are rough figures given in mm.
Product no. Description
96697826(521-002.1)
Side extraction device DN 4 / DN 8• with stop valve and filter• for fitting in dosing tank's coupling thread
96697988(521-048.2)
Side extraction device DN 4 / DN 8• with stop valve, filter and liquid riser• extraction to the right• with bushing connection for linking to dosing
tank
96696926(521-049.2)
Side extraction device DN 4 / DN 8• with stop valve, filter and liquid riser• extraction to the left• with bushing connection for linking to dosing
tank
96727271(521-004)
Side extraction device DN 20• with ball cock• with bushing connection for linking to dosing
tank
96727270(521-003)
Side extraction device DN 20• with ball cock and liquid riser• with bushing connection for linking to dosing
tank
TM04
124
0 50
08TM
04 1
241
5008
60
125
280
220
13
11.6 Drain valve R 3/4"Product number: 96689132 (520-008.1)• PVC / EPDM drain valve for fitting in dosing tank's coupling
thread– Unscrew stopper – Drill open threaded hole– Screw in drain valve and seal with Teflon tape.
Fig. 11 Drain valve
11.7 Aeration / ventilation valve for dosing tank• When fitting the aeration / ventilation valve in the dosing tank,
note the direction indicated by the arrow on the valve. The directions for fitting are:– for ventilation valve: arrow pointing upwards (a)– for aeration valve and return: arrow pointing downwards (b)
• Produce Ø 24 hole on top of dosing tank• Attach valve with seal ring underneath and use union nut to
screw down from the opposite side.
Fig. 12 Aeration / ventilation valve
11.8 Filling unit Product number: 96727265 (520-003)• PVC / EPDM filling unit for filling the dosing tank with liquid
media• With G 1" bushing connection to link with the dosing tank (hole
must be produced by the customer).• Connection pipe with DN 15 bonded connection
Fig. 13 Filling unit
11.9 Funnel release deviceProduct number: 96726979 (514-020)• PVC / EPDM funnel release device for flushing media in
powder form in 300 l, 500 l, 1000 l size dosing tanks• With DN 40 bushing connection for linking to dosing tank• Screw connection with DN 20 bonded socket joint for
connecting to PVC 25 x 1.9 pipe for flushing water
Fig. 14 Funnel release device
12. DisposalThis product and all its associated parts must be disposed of in an environmentally friendly manner.1. Suitable private waste disposal operations can be used here.2. If no such operations exist or if they refuse to process the
waste, the product can be sent to the closest Grundfos or Grundfos Alldos branch or service centre.
TM04
123
2 50
08TM
04 1
242
5008
Item Description
1 Valve2 Union nut3 Sealing ring4 Dosing tank
(a) Ventilation valve(b) Aeration valve / return
Product no. Material
96694401 (520-020) PVC / Viton95700621 (520-020.1) PVC / EPDM95714113 (520-021) PP / Viton95700727 (520-021.1) PP / EPDM
1
3
4
2
Ø24
(a) (b)TM
04 1
243
5008
TM04
124
4 50
08
DN 15
G1“
150
Ø 270
Ø 140
Ø 70
120
283
Subject to technical changes without notice.
14
ArgentinaBombas GRUNDFOS de Argentina S.A.Ruta Panamericana km. 37.500 Lote 34A1619 - GarinPcia. de Buenos AiresPhone: +54-3327 414 444Telefax: +54-3327 411 111
AustraliaGrundfos AlldosDosing & DisinfectionALLDOS Oceania Pty. Ltd.Unit 3 / 74 Murdoch CircuitAcacia Ridge QLD 4100Phone: +61 (0)7 3712 6888Telefax: +61 (0)7 3272 5188E-mail: [email protected]
AustraliaGRUNDFOS Pumps Pty. Ltd. P.O. Box 2040 Regency Park South Australia 5942 Phone: +61-8-8461-4611 Telefax: +61-8-8340 0155
AustriaGRUNDFOS Pumpen Vertrieb Ges.m.b.H.Grundfosstraße 2 A-5082 Grödig/Salzburg Tel.: +43-6246-883-0 Telefax: +43-6246-883-30
BelgiumN.V. GRUNDFOS Bellux S.A. Boomsesteenweg 81-83 B-2630 Aartselaar Tél.: +32-3-870 7300 Télécopie: +32-3-870 7301
BelorussiaПредставительство ГРУНДФОС в Минске220123, Минск,ул. В. Хоружей, 22, оф. 1105Тел.: +(37517) 233 97 65Факс: (37517) 233 9769E-mail: [email protected]
Bosnia/HerzegovinaGRUNDFOS SarajevoTrg Heroja 16,BiH-71000 SarajevoPhone: +387 33 713 290Telefax: +387 33 659 079e-mail: [email protected]
BrazilMark GRUNDFOS Ltda.Av. Humberto de Alencar Castelo Branco, 630CEP 09850 - 300São Bernardo do Campo - SPPhone: +55-11 4393 5533Telefax: +55-11 4343 5015
BulgariaGRUNDFOS Pumpen VertriebRepresentative Office - BulgariaBulgaria, 1421 SofiaLozenetz District105-107 Arsenalski blvd. Phone: +359 2963 3820, 2963 5653Telefax: +359 2963 1305
CanadaGRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: +1-905 829 9533 Telefax: +1-905 829 9512
ChinaGrundfos AlldosDosing & DisinfectionALLDOS (Shanghai) Water Technology Co. Ltd.West Unit, 1 Floor, No. 2 Building (T 4-2)278 Jinhu Road, Jin Qiao Export Processing ZonePudong New Area Shanghai, 201206Phone: +86 21 5055 1012Telefax: +86 21 5032 0596E-mail: [email protected]
ChinaGRUNDFOS Pumps (Shanghai) Co. Ltd.22 Floor, Xin Hua Lian Building755-775 Huai Hai Rd, (M)Shanghai 200020PRCPhone: +86-512-67 61 11 80Telefax: +86-512-67 61 81 67
CroatiaGRUNDFOS predstavništvo ZagrebCebini 37, BuzinHR-10010 ZagrebPhone: +385 1 6595 400 Telefax: +385 1 6595 499
Czech RepublicGRUNDFOS s.r.o.Čapkovského 21779 00 OlomoucPhone: +420-585-716 111Telefax: +420-585-716 299
DenmarkGRUNDFOS DK A/S Martin Bachs Vej 3 DK-8850 Bjerringbro Tlf.: +45-87 50 50 50 Telefax: +45-87 50 51 51 E-mail: [email protected]/DK
EstoniaGRUNDFOS Pumps Eesti OÜPeterburi tee 92G11415 TallinnTel: + 372 606 1690Fax: + 372 606 1691
FinlandOY GRUNDFOS Pumput AB Mestarintie 11 FIN-01730 Vantaa Phone: +358-3066 5650 Telefax: +358-3066 56550
FranceGrundfos AlldosDosing & DisinfectionALLDOS S.A.R.L.7, rue GutenbergF-67610 La WantzenauTél.: +33-3 88 59 26 26Télécopie: +33-3 88 59 26 00E-mail : [email protected]
FrancePompes GRUNDFOS Distribution S.A. Parc d’Activités de Chesnes 57, rue de Malacombe F-38290 St. Quentin Fallavier (Lyon) Tél.: +33-4 74 82 15 15 Télécopie: +33-4 74 94 10 51
GermanyGrundfos AlldosDosing & DisinfectionALLDOS Eichler GmbHReetzstraße 85D-76327 Pfinztal (Söllingen)Tel.: +49 7240 61-0 Telefax: +49 7240 61-177E-mail: [email protected]
GermanyGRUNDFOS GMBHSchlüterstr. 33D-40699 ErkrathTel.: +49-(0) 211 929 69-0 Telefax: +49-(0) 211 929 69-3799E-mail: [email protected] in Deutschland:E-mail: [email protected]
GreeceGRUNDFOS Hellas A.E.B.E. 20th km. Athinon-Markopoulou Av. P.O. Box 71 GR-19002 Peania Phone: +0030-210-66 83 400 Telefax: +0030-210-66 46 273
Hong KongGRUNDFOS Pumps (Hong Kong) Ltd. Unit 1, Ground floor Siu Wai Industrial Centre 29-33 Wing Hong Street & 68 King Lam Street, Cheung Sha Wan Kowloon Phone: +852-27861706 / 27861741 Telefax: +852-27858664
HungaryGRUNDFOS Hungária Kft.Park u. 8H-2045 Törökbálint, Phone: +36-23 511 110Telefax: +36-23 511 111
IndiaGRUNDFOS Pumps India Private Limited118 Old Mahabalipuram RoadThoraipakkamChennai 600 096Phone: +91-44 2496 6800
IndonesiaPT GRUNDFOS Pompa Jl. Rawa Sumur III, Blok III / CC-1 Kawasan Industri, Pulogadung Jakarta 13930 Phone: +62-21-460 6909 Telefax: +62-21-460 6910 / 460 6901
IrelandGRUNDFOS (Ireland) Ltd. Unit A, Merrywell Business ParkBallymount Road LowerDublin 12 Phone: +353-1-4089 800 Telefax: +353-1-4089 830
ItalyGRUNDFOS Pompe Italia S.r.l. Via Gran Sasso 4I-20060 Truccazzano (Milano)Tel.: +39-02-95838112 Telefax: +39-02-95309290 / 95838461
JapanGRUNDFOS Pumps K.K.Gotanda Metalion Bldg. 5F,5-21-15, Higashi-gotandaShiagawa-ku, Tokyo, 141-0022 JapanPhone: +81 35 448 1391Telefax: +81 35 448 9619
KoreaGRUNDFOS Pumps Korea Ltd.6th Floor, Aju Building 679-5Yeoksam-dong, Kangnam-ku, 135-916Seoul, KoreaPhone: +82-2-5317 600Telefax: +82-2-5633 725
LatviaSIA GRUNDFOS Pumps Latvia Deglava biznesa centrsAugusta Deglava ielā 60, LV-1035, Rīga,Tālr.: + 371 714 9640, 7 149 641Fakss: + 371 914 9646
LithuaniaGRUNDFOS Pumps UABSmolensko g. 6LT-03201 VilniusTel: + 370 52 395 430Fax: + 370 52 395 431
MalaysiaGRUNDFOS Pumps Sdn. Bhd.7 Jalan Peguam U1/25Glenmarie Industrial Park40150 Shah AlamSelangor Phone: +60-3-5569 2922Telefax: +60-3-5569 2866
MéxicoBombas GRUNDFOS de México S.A. de C.V. Boulevard TLC No. 15Parque Industrial Stiva AeropuertoApodaca, N.L. 66600Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010
NetherlandsGrundfos AlldosDosing & DisinfectionALLDOS BVLeerlooiersstraat 6NL-8601 WK SneekTel.: +31-51 54 25 789Telefax: +31-51 54 30 550E-mail: [email protected]
NetherlandsGRUNDFOS NetherlandsVeluwezoom 351326 AE AlmerePostbus 22015 1302 CA ALMERE Tel.: +31-88-478 6336 Telefax: +31-88-478 6332 e-mail: [email protected]
New ZealandGRUNDFOS Pumps NZ Ltd.17 Beatrice Tinsley CrescentNorth Harbour Industrial EstateAlbany, AucklandPhone: +64-9-415 3240Telefax: +64-9-415 3250
NorwayGRUNDFOS Pumper A/S Strømsveien 344 Postboks 235, Leirdal N-1011 Oslo Tlf.: +47-22 90 47 00 Telefax: +47-22 32 21 50
PolandGRUNDFOS Pompy Sp. z o.o.ul. Klonowa 23Baranowo k. PoznaniaPL-62-081 PrzeźmierowoTel: (+48-61) 650 13 00Fax: (+48-61) 650 13 50
PortugalBombas GRUNDFOS Portugal, S.A. Rua Calvet de Magalhães, 241Apartado 1079P-2770-153 Paço de ArcosTel.: +351-21-440 76 00Telefax: +351-21-440 76 90
RomâniaGRUNDFOS Pompe România SRLBd. Biruintei, nr 103 Pantelimon county IlfovPhone: +40 21 200 4100Telefax: +40 21 200 4101E-mail: [email protected]
RussiaООО ГрундфосРоссия, 109544 Москва, ул. Школьная 39Тел. (+7) 495 737 30 00, 564 88 00Факс (+7) 495 737 75 36, 564 88 11E-mail [email protected]
Serbia GRUNDFOS Predstavništvo BeogradDr. Milutina Ivkovića 2a/29YU-11000 Beograd Phone: +381 11 26 47 877 / 11 26 47 496Telefax: +381 11 26 48 340
SingaporeGRUNDFOS (Singapore) Pte. Ltd. 24 Tuas West Road Jurong Town Singapore 638381 Phone: +65-6865 1222 Telefax: +65-6861 8402
SloveniaGRUNDFOS PUMPEN VERTRIEB Ges.m.b.H.,Podružnica LjubljanaŠlandrova 8b, SI-1231 Ljubljana-ČrnučePhone: +386 1 568 0610Telefax: +386 1 568 0619E-mail: [email protected]
South AfricaGrundfos AlldosDosing & DisinfectionALLDOS (Pty) LTD98 Matroosberg Road, Waterkloof ParkP.O. Box 36505, Menlo Park 01020181 ZA Pretoria E-mail: [email protected]
SpainBombas GRUNDFOS España S.A. Camino de la Fuentecilla, s/n E-28110 Algete (Madrid) Tel.: +34-91-848 8800 Telefax: +34-91-628 0465
SwedenGRUNDFOS AB (Box 333) Lunnagårdsgatan 6 431 24 Mölndal Tel.: +46(0)771-32 23 00 Telefax: +46(0)31-331 94 60
SwitzerlandGrundfos AlldosDosing & DisinfectionALLDOS International AGSchönmattstraße 4 CH-4153 ReinachTel.: +41-61-717 5555Telefax: +41-61-717 5500E-mail: [email protected]
SwitzerlandGRUNDFOS Pumpen AG Bruggacherstrasse 10 CH-8117 Fällanden/ZH Tel.: +41-1-806 8111 Telefax: +41-1-806 8115
TaiwanGRUNDFOS Pumps (Taiwan) Ltd. 7 Floor, 219 Min-Chuan Road Taichung, Taiwan, R.O.C. Phone: +886-4-2305 0868Telefax: +886-4-2305 0878
ThailandGRUNDFOS (Thailand) Ltd. 92 Chaloem Phrakiat Rama 9 Road,Dokmai, Pravej, Bangkok 10250Phone: +66-2-725 8999Telefax: +66-2-725 8998
TurkeyGRUNDFOS POMPA San. ve Tic. Ltd. Sti.Gebze Organize Sanayi Bölgesi Ihsan dede Caddesi,2. yol 200. Sokak No. 20441490 Gebze/ KocaeliPhone: +90 - 262-679 7979Telefax: +90 - 262-679 7905E-mail: [email protected]
UkraineТОВ ГРУНДФОС УКРАЇНА 01010 Київ, Вул. Московська 8б, Тел.:(+38 044) 390 40 50 Фах.: (+38 044) 390 40 59E-mail: [email protected]
United Arab EmiratesGRUNDFOS Gulf DistributionP.O. Box 16768Jebel Ali Free ZoneDubaiPhone: +971-4- 8815 166Telefax: +971-4-8815 136
United KingdomGrundfos AlldosDosing & DisinfectionALLDOS Ltd.39 Gravelly Industrial Park, Tyburn RoadBirmingham B24 8TGPhone: +44-121-3283336Telefax: +44-121-3284332E-mail: [email protected]
United KingdomGRUNDFOS Pumps Ltd. Grovebury Road Leighton Buzzard/Beds. LU7 8TL Phone: +44-1525-850000 Telefax: +44-1525-850011
U.S.A.GRUNDFOS Pumps Corporation 17100 West 118th TerraceOlathe, Kansas 66061Phone: +1-913-227-3400 Telefax: +1-913-227-3500
UsbekistanПредставительство ГРУНДФОС в Ташкенте700000 Ташкент ул.Усмана Носира 1-й тупик 5Телефон: (3712) 55-68-15Факс: (3712) 53-36-35
Addresses revised 02.04.2009
www.grundfosalldos.com
Being responsible is our foundationThinking ahead makes it possible
Innovation is the essence
15.750100 V1.0
GB95714712 0309