2015-July
Restricted
Page 1 EZ / Marketing Communications
Restricted dresser-rand.com
DRESSER-RANDGuascor engines & gensetsVersion 0.1/ English / October 2015
2015-July
Restricted
Page 2 EZ / Marketing Communications
Safe Harbor DisclosureThe Private Securities Litigation Reform Act of 1995 provides a “safe harbor” for certain forward-looking statements so long as such information is identified as forward-looking and is accompanied by meaningful cautionary statements identifying important factors that could cause actual results to differ materially from those projected in the information.
The use of words such as “may”, “might”, “will”, “should”, “expect”, “plan”, “outlook”, “anticipate”, “believe”, “estimate", "appear”, “project”, “intend”, “future”, “potential” or “continue”, and other similar expressions are intended to identify forward-looking statements.
All of these forward-looking statements are based on estimates and assumptions by our management that, although we believe to be reasonable, are inherently uncertain. Forward-looking statements involve risks and uncertainties, including, but not limited to, economic, competitive, governmental and technological factors outside of our control, that may cause our business, industry, strategy or actual results to differ materially from the forward-looking statements.
These risks and uncertainties may include those discussed in the Company’s most recent filings with the Securities and Exchange Commission, and other factors which may not be known to us. Any forward-looking statement speaks only as of its date. We undertake no obligation to publicly update or revise any forward-looking statement, whether as a result of new information, future events or otherwise, except as required by law.
ConfidentialityAny person allowing themselves to directly or indirectly receive the information contained in this presentation agrees that this presentation and all information contained herein and/or in any way distributed to the Receiver with respect to the same (verbal or otherwise) is the confidential and proprietary property of Dresser-Rand Company and is being provided to and received by the Receiver in confidence.
Receiver agrees not to divulge the contents hereof to any third party without the prior written approval of Dresser-Rand’s duly authorized representative.
Receiver shall advise any permitted recipient of the confidential information of the nature of the same and obtain their agreement to be bound to these terms before such confidential information is disclosed to them. Receiver on behalf of its principal, representatives, employees and themselves individually do hereby unconditionally agree to the terms hereof and agree to defend, indemnify, and hold Dresser-Rand harmless from and against any and all damages that result from Receiver’s failure to strictly comply with these terms. Receiver further agrees that failure to comply with these terms will cause Dresser-Rand to suffer irreparable harm. Your decision to remain and receive the information about to be presented to you shall constitute your unconditional acceptance to the foregoing.
2015-July
Restricted
Page 3 EZ / Marketing Communications
Contenido
Introducción a Siemens / EISA
Productos y Aplicaciones
Alternativas
Legislación de emisiones
C
D
E
Introducción a Engine Business (EB) B
2015-July
Restricted
Page 4 EZ / Marketing Communications
Industrial Gas Turbines
Up to 60 MW
• Efficiency• Reliability• Flexibility• Environmental
compatibility• Low lifecycle costs and
ROI1)
• Access to heavy duty gas turbines >100 MW
Up to 66 MW
• Most reliable and easily maintained
• Benchmark for fuel economy and cost savings
• Highest efficiency and fast-start capabilities
Up to 250 MW
• Highest efficiency• Excellent flexibility for
complex processes• Economical
installation and operation
• Modular design• Customized steam
path
Up to 100 MW
• Compact• Low weight• High efficient
asynchronous/synchronous and variable speed drives
• Fit for purpose auxiliaries
Aero derivative Gas Turbines
Steam Turbines
Electric Drives
Up to 1,4 MW
High-Speed Engines
1) ROI: Return on Investment
Product Portfolio (I)
A. Introducción a Siemens / EIS
• Highest global (electrical +thermal) efficiency
• Interchangeable spare parts
• Low Life Cycle Parts• Easy maintenance• Flexibility for
powergen and CHP requirements
2015-July
Restricted
Page 5 EZ / Marketing Communications
Reciprocating
Gas Field and Process
• Performance
• Efficiency
• Reliability
• Low maintenance
• For most demanding up-, mid-, and downstream applications
Engineered integrally geared
Air Separation, Chemicals
• Outstanding efficiencies according to clients’ requirements
• Versatile
• Reliable
• Customized and proven
Standardizeddesign
Air Separation
• Cost-efficient
• Efficient
• Sustainable
• Field-proven compression for low lifecycle costs
Centrifugal
Oil and Gas Upstream, LNG,
Refining and Petrochemicals
• Vertical and horizontal split compressors incl. high pressure applications
• Fit for purpose with reliable field-proven design
• Best efficiencies for highest plant availability
Pipeline
Gas Transport
• Cost-effective and technologically advanced solution
• For highest efficiencies
• Flexible design to accommodate all expected conditions
Single stage
Industry, Metallurgy,
Utilities
• Lowest capital expenditure
• Long time uninterrupted operation
• Highest aerodynamic efficiency
Turbo
Product Portfolio (II)
A. Introducción a Siemens / EIS
2015-July
Restricted
Page 6 EZ / Marketing Communications
Industrial Compressor Applications (ICA)
Air Separation(ASU)
Mornago, Italy
Frankenthal, Germany
Helsingør, Denmark
Leipzig, Germany
Springfield, USA
Vadodara, India
Duisburg, Germany
Huludao, China
Worldwide Engineering, Manufacturing, Testing and Packaging
Engine Business(EB)
KG2 Gas Turbines
Zumaia, Spain
Kongsberg, Norway Miñano, Spain
Nov 2015
A. Introducción a Siemens / EIS
Environmental and Industrial Solutions (EIS)
2015-July
Restricted
Page 7 EZ / Marketing Communications
Contenido
Introducción a Siemens / EISA
Productos y Aplicaciones
Alternativas
Legislación de emisiones
C
D
E
Introducción a Engine Business (EB) B
2015-July
Restricted
Page 8 EZ / Marketing Communications
B. Introducción a EB
Sobre Guascor® Engines & GensetsTrayectoria
Los motores y generadores Guascor® están diseñados, fabricados y comercializados comoPower Systems and Energy Solutions.
50 años desarrollando, fabricando y vendiendo motores
de combustión interna.
2015-July
Restricted
Page 9 EZ / Marketing Communications
B. Introducción a EB
Guascor® Engines & Gensets : Historia (1 de 2)
Trayectoria
1988: Motores GasSe adentra en la tecnologíade motores de gas, utilizando la licencia de fabricación de WAUKESHA (1984), así como sutransmisión de tecnología.
1966: Motor DieselGuascor se funda en Bilbao. La Empresa vende motoresDiesel para aplicacionesmarinas.
1966 1988 20001992
1996: R&D CenterSe establece en Miñano(Alava) el centro de Investigación y Desarrollo, puntero a nivel mundial.
1996
1992: Se lanza el primer motor de biogás.
2000: lanzamiento de las familias SF- SFGLD
2003
2003: Lanzamiento Motor de gas de bajacompresión para gas de bajo número de metano.
2007
2007: Lanzamiento de lasfamilias Biodiesel and Dual Fuel
2015-July
Restricted
Page 10 EZ / Marketing Communications
B. Introducción a EB
Guascor Engines & Gensets : Historia (2 de 2)
Trayectoria
2009 2010
2009: Lanzamiento SFGM 560
2009: Aumento de potencia enmotores Diesel marinos.
2010: Se lanza el motor HGM 240 (Biogas)
2011Dresser-Rand adquiere Guascor
2011 20122008
2008: HGM 560Se relanza el modelo con eficiencia mejorada
2013 2014
2013: Lanzamiento de motores Stand By, Prime y motores estequiométricos
2014: Lanzamiento de motores Mechanical Drive y Rich Burn2012: Se lanza motor
prototipo de Ethanol
2015-July
Restricted
Page 11 EZ / Marketing Communications
Contenido
Introducción a Siemens / EISA
Productos y Aplicaciones
Alternativas
Legislación de emisiones
C
D
E
Introducción a Engine Business (EB) B
2015-July
Restricted
Page 12 EZ / Marketing Communications
GAS NATURAL/ BIOGAS
GAS DE SINTESIS
DUAL-FUEL
DIESEL INDUSTRIAL
Engines Gensets1200 rpm 1500 rpm 1800 rpm 1200 rpm 1500 rpm 1800 rpm
Type Cyl. Displ. kWb kWb kWb kWe kWe kWe
Atmospheric enginesFG 180 6L 18 - 150 180 - 142 171FG 240 8L 24 - 200 238 - 191 226
Mechanicalcarburation
FGLD 180 6L 18 - 275 300 - 264 287FGLD 240 8L 24 - 360 400 - 347 385FGLD 360 12V 36 - 550 600 - 529 577FGLD 480 16V 48 - 725 800 - 702 774
Electronic Carburation
SFGLD 180 6L 18 252 315 350 242 300 336SFGLD 240 8L 24 335 419 453 322 405 436SFGLD 360 12V 36 503 630 700 486 609 676SFGLD 480 16V 48 670 838 906 649 812 874SFGLD 560 16V 56 788 985 - 762 957 -
Miller cycle, Elect. Carburation SFGM 560 16V 56 - 1.055 1.100 - 1.025 1.065
High performance Miller cycle engines
HGM 240 8L 24 - 520 - - 502 -HGM 560 16V 56 1.040 1.240 1.350 1.007 1.204 1.308
Engines Gensets
1200 rpm 1500 rpm 1800 rpm 1200 rpm 1500 rpm 1800 rpm
Type Cyl. Displ. kWb kWb kWb kWe kWe kWe
SFGLD 180 6L 18 209 263 283 199 253 271
SFGLD 240 8L 24 281 350 377 269 338 362
SFGLD 360 12V 36 418 526 565 401 508 544
SFGLD 480 16V 48 561 700 754 541 678 729
SFGLD 560 16V 56 590 735 - 569 711 -
Engines Gensets
1500 rpm 1800 rpm 1500 rpm 1800 rpm
Type Cyl. Displ. kWb kWb kWe kWe
SFD 180 6L 18 360 407 347 394
SFD 240 8L 24 480 543 464 523
SFD 360 12V 36 720 815 698 787
SFD 480 16V 48 960 1.087 930 1.048
Engines GensetsContinuos Duty ( kWb) Prime Duty (kWb) Continuos Duty ( kWe) Prime Duty (kWe)
Type Cyl. Displ. 1.500 1.800 1.500 1.800 50 Hz 60Hz 50 Hz 60HzSF180TA-LG 6L 18 395 410 425 445 381 394 409 427SF240TA-LG 8L 24 525 545 565 590 507 525 542 565SF360TA-LG 12V 36 785 820 850 890 760 791 820 857SF480TA-LG 16V 48 1.045 1.095 1.130 1.180 1.012 1.056 1.092 1.135
C. Productos y Aplicaciones
C.1. Aplicaciones industriales y Oil& GasEspecificaciones técnicas de los motores
METHANE NUMBER 45 METHANE NUMBER 551200 rpm 1500 rpm 1800 rpm 1200 rpm 1500 rpm 1800 rpm
Type kWb kWb kWb kWe kWe kWe
Flare Gas
SFGLD 180 220 275 300 252 315 350SFGLD 240 290 360 400 335 419 453SFGLD 360 440 550 600 503 630 700SFGLD 480 580 725 800 670 838 906SFGLD 560 671 900 905 788 1055 1067
MOTORES PARA GASES ESPECIFICOS
2015-July
Restricted
Page 13 EZ / Marketing Communications
PL
ATA
FO
RM
AS
T
EC
NO
LO
GIC
AS MOTORES
GAS
INDUSTRIAL
Efic. energética
MOTORES DIESEL
O&G
Bio Energía
Power Gen Waste to Energy CHP Flare Gas
(*)CHP: Combined Heat Power , WTE: Waste To Energy
Energía distrib.Distribuc. energía Mechanical Drive Propulsión
MARINO
PumpPower Gen
Compression /
Pump
Power GenCHP Main & Auxiliary
APLICACIONES & MERCADOS
C.2 Rango de soluciones
Tecnología aplicada a diferentes necesidades de mercado
SE
RV
ICIO
S
PLAPermits, Licenses &
Authorizations
Technical Assistance
Engine Supply
Original Spare Parts
Supply
EPCEngineering, SCM,
Construction, Commissioning
DUAL – FUEL ENGINES
C. Productos y Aplicaciones
2015-July
Restricted
Page 14 EZ / Marketing Communications
Contenido
Introducción a Siemens / EISA
Productos y Aplicaciones
Alternativas
Legislación de emisiones
C
D
E
Introducción a Engine Business (EB) B
2015-July
Restricted
Page 15 EZ / Marketing Communications
D. Legislaciones de emisiones
D.1. España
• DECRETO 833/1975• NOx 300 ppm• CO 500 ppm• SO2 4300 mg/mn
3
• REAL DECRETO 815-2013 -> IPCC instalaciones de más de 50 MWth
• REAL DECRETO 100-2011 Nuevo listado de actividades potencialmente contaminantes
• CATALUÑADecret 319/1998 y la IT-AT 003
• NOx 1500 mg/mn3 al 5%O2
• CO 1000 mg/mn3 al 5%O2
• BIOGÁS SO2 300 mg/mn3 al 5%O2 BIOMASA SO2 180 mg/mn
3 al 5%O2
Formaldehido 60 mg/mn3 Partículas 50 mg/mn
3
• NAVARRADecreto 6-2002
• NOx 500 mg/mn3 al 5%O2
• CO 1000 mg/mn3 al 5%O2
• SO2 300 mg/mn3 al 5%O2
• COT 20 mg/mn3 al 5%O2
2015-July
Restricted
Page 16 EZ / Marketing Communications
D. Legislaciones de emisiones
D.2. Europa
2015-July
Restricted
Page 17 EZ / Marketing Communications
D. Legislaciones de emisiones
D.2. Europa
Directiva (UE) 2015/2193 DIRECTIVA INSTALACIONES DE MEDIANA
POTENCIA
Valores límite para plantas existentes de 1 a 50 MWth de potencia de combustible:
- GAS NATURAL: 190 mg/mn3 al 15%O2 (507 mg/mn
3 al 5%O2)- Otros gases: 190 mg/mn
3 al 15%O2 (507 mg/mn3 al 5%O2)
Desde el 1 de enero de 2025 para plantas existentes de potencia térmica superior a 5 MW.Desde el 1 de enero de 2030 para plantas existentes de potencias de 1 a 5 MWTodas las instalaciones deben estar registras un año antes.
Valores límite para plantas nuevas de 1 a 50 MWth de potencia de combustible:- GAS NATURAL: 95 mg/mn
3 al 15%O2 (253 mg/mn3 al 5%O2)
- Otros gases: 190 mg/mn3 al 15%O2 (507 mg/mn
3 al 5%O2)Desde el 20 de diciembre de 2018 para plantas existentes
2015-July
Restricted
Page 18 EZ / Marketing Communications
D. Legislaciones de emisiones
D.2. Europa
Directiva (UE) 2015/2193 DIRECTIVA INSTALACIONES DE MEDIANA
POTENCIAExenciones:- Plantas de combustión cuyos gases de escape sean usados para
calentamiento directo, secado o cualquier otro tratamiento de objetos o materiales.
- Plantas de combustión cuyos gases sean usados para calefacción en centros de trabajo (calentamiento de espacios interiores a fin de mejorar las condiciones de los lugares de trabajo)
- Motores en plataformas marinas (offshore).
- Plantas que consuman fueles de refinería o con otros fueles para la producción de energía en refinería oil and gas.
- Actividades de investigación y desarrollo
2015-July
Restricted
Page 19 EZ / Marketing Communications
Contenido
Introducción a Siemens / EISA
Productos y Aplicaciones
Alternativas
Legislación de emisiones
C
D
E
Introducción a Engine Business (EB) B
2015-July
Restricted
Page 20 EZ / Marketing Communications
E. Alternativas
Actuar sobre parámetros de funcionamiento/configuración de motor:
- Menor rendimiento (mayor consumo)- Mayor potencia térmica
E.1. Parámetros de funcionamiento/configuración de motor
2015-July
Restricted
Page 21 EZ / Marketing Communications
E. Alternativas
E.1. Parámetros de funcionamiento/configuración de motor
2015-July
Restricted
Page 22 EZ / Marketing Communications
E. Alternativas
E.1. Parámetros de funcionamiento/configuración de motor
2015-July
Restricted
Page 23 EZ / Marketing Communications
E. Alternativas
E.1. Parámetros de funcionamiento/configuración de motor
2015-July
Restricted
Page 24 EZ / Marketing Communications
E. Alternativas
E.1. Parámetros de funcionamiento/configuración de motor
2015-July
Restricted
Page 25 EZ / Marketing Communications
Aumento de avance de encendido:
- Mejora rendimiento para mismo valor de NOx- Disminuye margen de actuación de mariposa- Disminuye margen a “missfire”- Disminuye margen a detonación
Actuación sobre configuración de turbocompresor:- Mejoras en el margen de mariposa
Actuación sobre sistema de encendido:- Diseño de bujía- Unidades de encendido de mayor energía (sobre todo en biogás)
E. Alternativas
E.1. Parámetros de funcionamiento/configuración de motor
2015-July
Restricted
Page 26 EZ / Marketing Communications
E. Alternativas
Catalizador SCR (Urea):- Reducción de NOx (hasta 95%)- Mayor coste de inversión (25-30%)- Mayor coste de mantenimiento- Mayor rendimiento (menor consumo)
E.2. Catalizador SCR (urea)
Catalizador oxidativo:Sólo eliminan CO y NMHC
Catalizador SCR (Urea):Sólo elimina NOx
2015-July
Restricted
Page 27 EZ / Marketing Communications
E. Alternativas
Catalizador SCR (Urea):- Requiere depósito de Urea- Recambio de sustrato catalítico (mantenimiento)
E.2. Catalizador SCR (urea)
2015-July
Restricted
Page 28 EZ / Marketing Communications
E. Alternativas
E.2. Catalizador SCR (urea)
Conteiner con motor HGM560 1 Mwe. Conteiner Módulo catalítico y Recuperación de calor .
Cuadro de control Módulo catalítico Intercambiadores SCR + OXI Recuper. de calor
2015-July
Restricted
Page 29 EZ / Marketing Communications
E. Alternativas
Motores mezcla rica + catalizador 3 vías- Reducción de NOx (99%)- Menor rendimiento (mayor consumo) - Incremento en coste menor (3%-5%)- Eliminación efectiva de otros contaminantes (CO, NMHC, formaldehido)- Mayor potencia térmica
E.3. Motor Mezcla Rica + Catalizador de 3 Vías
2015-July
Restricted
Page 30 EZ / Marketing Communications
E. Alternativas
E.3. Motor Mezcla Rica + Catalizador de 3 Vías
2015-July
Restricted
Page 31 EZ / Marketing Communications
Gracias por su atención