DTAC 3G 2.1GHz - Site Solution for
South, North & North East
www.huawei.com
2HUAWEI TECHNOLOGIES CO., LTD.
New 3G cabinet Bay-face
3HUAWEI TECHNOLOGIES CO., LTD.
4HUAWEI TECHNOLOGIES CO., LTD.
5HUAWEI TECHNOLOGIES CO., LTD.
Circuit Breaker inside new 3G Enclosure
1. BTECH will install this cabinet on site and also install PGND cable (Ground cable) THW 1*16 sq.mm.
Green color in water proof flexible conduit from new cabinet to ground bar.
2. BBTECH will provide external alarm cable 4 core inside this cabinet 20m (For door alarm and FAN alarm).
Huawei will install this cable with Huawei external alarm cable to DTAC MDF.
63A
6HUAWEI TECHNOLOGIES CO., LTD.
New cabinet Inlet Assignment
DC input cable 25mm^2 to CB 63A
Optical patch cord to existing IPRAN
RRU power cable
CPRI cable / OIL
PGND cable 16mm^2 for cabinet
Alarm cable 3pcsTo Alarm box
1 inch
¾ inch
½ inch
Spare
MAIN 2
7HUAWEI TECHNOLOGIES CO., LTD.
Cable Inlet Assignment
Move Alarm cable 3pcs out and use this hole for patch cord from BBU 3G U2100
Existing 3G cabinet (IPRAN inside cabinet)
1 inch
¾ inch
½ inch
If existing IPRAN not in this cabinet, no need move alarm cable out.
8HUAWEI TECHNOLOGIES CO., LTD.
Circuit Breaker Requirement and Connecting
Circuit breaker in existing power supply
For Transmission For 2G BTS (125A)
9HUAWEI TECHNOLOGIES CO., LTD.
Circuit Breaker Requirement and Connecting (Have space)
If has spare circuit breaker 125A- use existing circuit breaker 125A connect DC cable 25 mm^2 to new 3G
U2100 enclosure
10HUAWEI TECHNOLOGIES CO., LTD.
New 3G U2100 Enclosure
63A
25 mm^2 cable
DC cable connection to new cabinet (Has existing CB)
11HUAWEI TECHNOLOGIES CO., LTD.
Circuit Breaker Requirement and Connecting (No Space)
If no space- Please install new circuit breaker 63A temporary inside cabinet.- Connect DC cable 25mm^2 from DC bar to new circuit breaker 63A.
12HUAWEI TECHNOLOGIES CO., LTD.
DC cable connection to new cabinet (no existing CB)
New 3G U2100 Enclosure
63A
25 mm^2 cable
New CB 63A
13HUAWEI TECHNOLOGIES CO., LTD.
CPRI/Jumper Line 1
Cable color marking
CPRI/Jumper Line 2
14HUAWEI TECHNOLOGIES CO., LTD.
PVC Tape 3M (From Local)
15HUAWEI TECHNOLOGIES CO., LTD.
How to connect all ground cable?
16HUAWEI TECHNOLOGIES CO., LTD.
Set the priority for grounding on the tower, as follows;
1) Connect to bus bar installed on tower by using 2 holes cable lug.
2) Connect to the main ground cable from tower to ground
How to connect all ground cable?
17HUAWEI TECHNOLOGIES CO., LTD.
3) Connect to lightning protection ground cable
4) Connect between the tower segments connection. (If any additional ground cable, can be grounded to this cable by using C-clamps as shown below)
How to connect all ground cable?
18HUAWEI TECHNOLOGIES CO., LTD.
5) Run a new main ground cable from equipment to ground level and Connect the equipment on the tower to the new main ground cable with C-clamps.
How to connect all ground cable?
19HUAWEI TECHNOLOGIES CO., LTD.
Solution –Part 1
1) Tower• Guyed mast• Self Slope• Square Self (L type)
20HUAWEI TECHNOLOGIES CO., LTD.
Solution –Normal Tower
Type S IDCriterias( GM /L)
Tower type Site Solution Description Antenna LevelMounting
typeAntenna Problem
2G Only
1.1a
2G Ant <= 3
Guy Install new 3G U2100 ant same level 2G. same level 2G Single arm mounting
1.1b Sq. Self / Self slope Install new 3G U2100 ant same level 2G. same level 2GSingle arm mounting
Special mounting
1.2a
2G Ant > 3
Guy / Sq. Self
Install new 3G U2100 ant below level 2G . below level 2G
Single arm mounting
1.2b Self slopeSingle arm mounting
Special mounting
2G +3G (850)
2.1a 2G Ant <=3 , 3G (850) =3
Guy
Install new 3G U2100 ant same level 2G. same level 2G
Single arm mounting
2.1b Sq. Self; Self slopeSingle arm mounting
Special mounting
2.22G Ant > 3 and <= 6,
3G (850) = 3 Guy /Sq. Self / Self
slopeinstall new 3G U2100 ant same level 3G. same level 3G(U850)
Single arm mounting
Special mounting
2.3a
2G Ant > 6, 3G (850) = 3
Sq. Self /Self slope
priority-1 : install new 3G U2100 ant same level 3G. (Check by level 2 engineer)
same level 3G(U850)Single arm mounting
Special mounting
priority-2 : Re-enforce tower same level 3G(U850)Single arm mounting
Special mounting
2.3b Guy
priority-1 : install new 3G U2100 ant same or lower than 3G 850. (Check by level 2 engineer)
same level 3G(U850)Single arm mounting
Special mounting
priority-2 : Re-enforce tower same level 3G(U850)Single arm mounting
Special mounting
21HUAWEI TECHNOLOGIES CO., LTD.
Only 2G
22HUAWEI TECHNOLOGIES CO., LTD.
Solution 1.1a (2G ant <=3)
Condition:1.Only 2G2.tower&Antenna• Guyed mast
Solution:• Single band ant ,Install new 3G U2100
ant same level 2G.
Antenna mounting type:• Single arm mounting.
23HUAWEI TECHNOLOGIES CO., LTD.
Solution 1.1b (2G ant <=3)
Condition:1.Only 2G2.tower&Antenna• Square self (L type)/Self
slope
Solution:• Single band ant ,Install new 3G U2100
ant same level 2G.
Antenna mounting type:• Single arm mounting (Special
mounting)
24HUAWEI TECHNOLOGIES CO., LTD.
Solution 1.2a (2G ant >3)
Condition:1.Only 2G2.tower&Antenna• Guyed mast• Square self (L type)
Solution:• Single band ant ,Install new 3G
U2100 ant below level 2G.
Antenna mounting type:• Single arm mounting.
25HUAWEI TECHNOLOGIES CO., LTD.
Solution 1.2b (2G ant >3)
Condition:1.Only 2G2.tower&Antenna• Self slope
Solution:• Single band ant ,Install new 3G U2100
ant below level 2G.
Antenna mounting type:• Single arm mounting (Special
mounting)
26HUAWEI TECHNOLOGIES CO., LTD.
2G + 3G (850)
27HUAWEI TECHNOLOGIES CO., LTD.
Solution 2.1a {2G ant <=3, 3G (850)=3}
Condition:1. 2G + 3G (850)2.tower&Antenna• Guyed mast
Solution:• Single band ant ,Install new 3G U2100
ant same level 2G.
Antenna mounting type:• Single arm mounting.
28HUAWEI TECHNOLOGIES CO., LTD.
Solution 2.1b {2G ant <=3, 3G (850)=3}
Condition:1. 2G + 3G (850)2.tower&Antenna• Square self (L type)/Self
slope
Solution:• Single band ant ,Install new 3G U2100
ant same level 2G.
Antenna mounting type:• Single arm mounting (Special
mounting)
29HUAWEI TECHNOLOGIES CO., LTD.
Solution 2.2 {2G ant >3 and <=6, 3G (850)=3}
Condition:1. 2G + 3G (850)2.tower&Antenna• Guyed mast / Square self (L type) / Self
slope
Solution:• Single band ant ,Install new 3G U2100
ant same level 3G(U850).
Antenna mounting type:• Single arm mounting (Special
mounting)
30HUAWEI TECHNOLOGIES CO., LTD.
Solution 2.3a {2G ant >6, 3G (850)=3}
Condition:1. 2G + 3G (850)2.tower&Antenna• Square self (L type) / Self slope
Solution: priority 1• install new 3G U2100 ant same level
3G 850. (Check by level 2 engineer).
Antenna mounting type:• Single arm mounting (Special
mounting)
Solution: Priority 2• Re-enforce tower (Install same level
3G)
31HUAWEI TECHNOLOGIES CO., LTD.
Solution 2.3b {2G ant >6, 3G (850)=3}
Condition:1. 2G + 3G (850)2.tower&Antenna• Guy mast
Solution: priority 1• install new 3G U2100 ant same level
3G 850. (Check by level 2 engineer).
Antenna mounting type:• Single arm mounting (Special
mounting)
Solution: Priority 2• Re-enforce tower (install same level
3G)
32HUAWEI TECHNOLOGIES CO., LTD.
Solution –Part 22、 Special tower• Pole(3M)• Pole(6M/9M)• Wall-mount Pole• Electrical Pol
33HUAWEI TECHNOLOGIES CO., LTD.
Solution – Special Tower
Type S IDCriterias ( GM /L)
Tower type Site Solution Description Antenna LevelMounting
typeAntenna Problem
2G Only
3.1a 2G Ant <= 3 Pole 3 ,6 , 9
Priority-1 : install new 3G U2100 ant same level 2G same level 2G
Single mounting
T mounting
Down time 3 Hours
Priority-2 : Dual band antenna same level 2G ExistingDown time
3 Hours
3.1b 2G Ant > 3 Pole / Electrical
Pole
Priority-1: Check by level 2 engineer ; (Change to dual band 1800+2100 antenna)
same level 2G ExistingDown time
3 Hours
priority-2 : Re-enforce tower (Change to dual band 1800+2100 antenna)
same level 2G ExistingDown time
3 Hours
priority-3 : New Pole
priority-4 : Combiner Solution
2G +3G (850)
3.22G Ant >=3 , 3G (850) =3
Pole / Electrical Pole
Priority-1: Check by level 2 engineer ; (Change to dual band 850+2100 antenna)
same level 3G ExistingDown time
3 Hours
priority-2 : Re-enforce tower (Change to dual band 850+2100 antenna)
same level 3G ExistingDown time
3 Hours
priority-3 : New Pole
priority-4 : Combiner Solution
34HUAWEI TECHNOLOGIES CO., LTD.
Power supply Solution• Solution #1 : Add new rectifier module+ new battery• Solution #2 : Install new rectifier cabinet +battery
system• Solution # 3 : Replace existing rectifier
Note: only confirm solution, for other work will be done by DTAC.
35HUAWEI TECHNOLOGIES CO., LTD.
Solution #1 : Add new rectifier module+ new battery
AC cable
AIR
BTS
Rectifier &Battery
Transmission RRU 850
Combiner
Battery
Add new
module
Module
Add new Battery
RRU 2.1Ghz
2.1GhzCabinet
• Add new rectifier module 1 unit + Add Battery 1 String
36HUAWEI TECHNOLOGIES CO., LTD.
Solution #2 : Install new rectifier cabinet +battery system
AC cable
AIR
BTS
Existing Rectifier &Battery
Transmission RRU 850
Combiner
Battery
New Rectifier & Battery
for DTN
Module
2.1GhzCabinetBattery
RRU 2.1Ghz
Add new rectifier and battery 1 set ( 3 modules and 1 battery set )
37HUAWEI TECHNOLOGIES CO., LTD.
Solution # 3 : Replace existing rectifier
AC cable
AIR
BTS
Rectifier &Battery
Transmission RRU 850
Combiner
Battery
Module
Replace to new rectifier
cabinet
38HUAWEI TECHNOLOGIES CO., LTD.
Page 38