Part No. 19500556RCVAUXHALL
Installation of the towing electrics kit must be undertakenby a specialist workshop or an appropriately qualifiedperson. Before starting work, you must read the installationinstructions through completely. After installing the towingelectrics kit, the installation instructions should be keptwith the vehicle service documentation.
All claims under the guarantee will lapse in case of improper use ormodification of the towing electrics kit or any of its component parts.When driving without a trailer or load carrier, any adapter installedmust be removed from the electrical socket. We reserve the right toalter the design, content or colour. We accept no liability for anyerrors in these instructions. All details and illustrations are non-binding.
Fitting instructions
In case of missing a rear fog lamp on the trailer, it should be retrofitted.
We accept no responsibility and give no guarantee for technical andelectrical modifications made after the initial operation of the towingelectrics kit by the vehicle manufacturer and which may lead, forexample to malfunction of the trailer socket or its peripheries.
The trailer module is not diagnostics-capable. If the manufacturer’sdiagnostics processes or software-supported test mechanismsgenerate error reports directly or indirectly linked with trailer operation,the trailer module must be disconnected from the leads to the trailersocket and a new diagnostic process initiated.
Electric wiring kit for towbars / 7-pin / 12N / 12 Volt / ISO 1724
IMP
OR
TAN
T!
SUPPLIERS OF TOWBAR WIRING KITS FOR THE UK
Meriva B 06/10
1/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
GN
GN
Diagnosis function of control LEDs
Lamp substitution if the trailer indicators fail
The failure of a trailer indicator (right left or both sides) is reported to the driver in the towing vehicle's combi-instrumentvia a text message in the display, an increase in the flashing frequency and/or a control lamp for light failurecoming on.If an indicator fails the left or right rear tail light compensates for the faulty indicator by flashing at the correct frequency!If the indicator is activated, the corresponding rear tail lamp on the trailer becomes the indicator( lamp substitution):NOTE! The lamp substitution does not work if the Hazard warning lights have been activated.
e
RD
MANUAL
CAN-Data Wire
1.
2.
3.1x max 20 sec.
b
No CAN-Data Standby /Sleepmode=
a
GN
RD
2 x B+/30: PIN 2 + 4d
RD
c
2/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
3x
10x 5x
2x2x
2x
22-24 9-18
3-8
MANUAL
2x
3/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
1
90010216
Co
Co
ATTENTION!
The vehicle's cooling capacity may have to be increased when retrofitting a trailer coupling! You must observe themanufacturer's instructions!!
ATTENTION!
MANUAL
In order to avoid mal-functions and damage to the vehicle’s electrical system the earth terminal must be disconnectedfrom the vehicle’s battery before starting work!
Both the trailer module and the vehicle’s control unit for the electrical system can be damaged during work on theCAN data bus connections if the battery is not disconnected!
Please pay attention to the manufacturer’s instructions when disconnecting and reconnecting the vehicle’s battery!
SYMBOL EXPLANATION
Reverse
B+/30
20A
left (58-L) respectivelyright (58-R) tail light
stop light (54) /high mounted, third stop light (54)
turn signal indicator left
turn signal indicator right
rear fog light(s)
reversing light(s)
trailer / trailer recognition
Permanent current power supply
Ground or Earth (31)
ground connection battery terminal lug
positive connection battery terminal lug
fuse / fuse capacity 20 Ampère
12V
P
cigarette lighter /accessory socket
loudspeaker / buzzer
Park Distance Control
switch / source of function
Connect together
Disconnect
Look at / See further information
Look carefully at selected area
Present / Occupied / OK
Not present / Not occupied / Not OK
left
right
acoustic indication
attention / important advice
B+/30 Permanent power supply /13pin socket, chamber 9
charging wire for trailer battery /13pin socket, chamber 10
everse
4/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
3
2
4
5
a
1.
2.
3.
4.
5.
6.
7.
b
5/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
D FGB IE
RD
BK
GN
OR
VT
PK
BL
YL
WT
BR
GY
Black Schwarz Negro Noir Nero
Red Rot Rojo Rouge Rosso
Green Grün Verde Vert Verde
Orange Orange Naranja Orange Arancione
Violet Violett Violeta Violet Viola
Pink Pink Pink Rose Rosa
Blue Blau Azul Bleu Blu
Yellow Gelb Amarillo Jaune Giallo
White Weiss Blanco Blanc Bianco
Brown Braun Marrón Brun Marrone
Grey Grau Gris Gris Grigio
NL NP SDK
Preto Zwart Sort Svart
Vermelho Rood Rød Rød Röd
Verde Groen Grøn Grønt Grön
Laranja Oranje Orange Orange Orange
Violeta Violet Violet Fiolett Violett
Cor-de-Rosa Paars Pink Pink Rosa
Azul Blauw Blå Blått Blå
Amarelo Geel Gul Gult Gul
Branco Wit Hvid Hvitt Vit
Marrom Bruin Brun Brunt Brun
Cinzento Grijs Grå Grått Grå
CZFIN H
Musta Cerná Fekete
Punainen Cervená Piros
Vihreä Zelená Zöld
Oranssi Narancs
Violetti Fialová Ibolya
Pinkki Ruzová Rózsaszín
Sininen Modrá Kék
Keltainen •lutá Sárga
Valkoinen Bílá Fehér
Ruskea Hnedá Barna
Harmaa •edá Szürke
PL
Czarny
Czerwony
Zielony
Pomaranczowy
Fioletowy
Rózowy
Niebeski
Zólty
Bialy
Brazowy
Szary
Svart
Oran•ová
90500580
8
7
9
11
6
10
90500552
Belegung der Steckdose / Maximale AusgangsleistungSocket configuration / Maximum power outputCorrespondance des contacts de la prise / Puissance de sortie maximaleAbbinamento della presa / Uscita di alimentazione massimaIndeling van de stekkerdoos / maximaal uitgangsvermogen
ISO 1724
5/58-R
6/54
1/L
4/R
2
3/31
BK/WT
WT
BK/GN
BR
GY/RD
BK/RD
7/58-L GY/BK
21W
42W
21W
52W
63W
52W
+-
BR/YL
BR/YL
BK/YL
6/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
Option 1
Option 2
GN(CAN)
GN(CAN)
Pin 6 (GN)CAN
16 - 18
19 - 24
+
+
12
13 14
15
16
RD/YL
RD/BL
Cut to size!
BK/YL
BK/YL
7/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
X00000000
ooooooooooooooooo
Wichtig!Unbedingt Hinweise aus Bild 1 beachten!
Important!Please note informations in picture 1!
20
19
GNRD/BLRD/YL
17
18
Important!Please do not mount the fuse tap and itswiring output in the other direction!
RD/BLRD/YL
1.
2.
3.
4.
8/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
1.3.
2.
chamber 2
20A1. 3.
2.
chamber 3130A
21
22
23
24
chamber 7
lightGN
GN
180°
Important!Please note informations
in picture 1!
CAN
PIN 16
lightGN
chamber 9
2.
2.
1.
9/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
Important!Please do not mountthe fuse tap and itswiring output in the otherdirection!
Important!Please do not mountthe fuse tap and itswiring output in the otherdirection!
1.
3.
3.
MANUAL
90500004
13-pin7-pin
Optional: Adapter socket 62400001
27
25 26
28
30 31
29
90500507
everse
Supplementary harness
12S38400501
BL/YL
OPTIONALeverse
SETUP
1x
P
1. 2. 3.
4.
ON
LOC
K
Ignition ON
P
LED
The following lamp functions for the trailerare not supported by all towing vehicleswith DRL circuit:
• Rear lights• Side lights• Numberplate lights
The parking lights or dimmed headlightsmust be switched on to activate this function!
10/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL
32 33
35
34
P
P
MANUAL
MANUALSERVICE SERVICE MANUAL
OPTIONAL
Part-no.50400521RC
everse
Permanent power supply
Charging wire fortrailer battery
Dauerstrom
Ladeleitung
everse
PIN 9
PIN 10
Trailer Simulatorfor 7- and 13-pinSockets
everse
11/1187501338 / 31.10.2012
© ConWys AGWeb: www.rightconnections.co.ukemail: [email protected]
Sales: +44 0195 260 8750Technical: +44 0195 260 8938Fax -UK only: 0870 759 8366
Right Connections (UK) LimitedUnit 503, Queensway Business ParkHadley Park, TELFORD, Shropshire TF1 7UL