DAIRYLANDELECTRICAL INDUSTRIESALWAYS RUGGED. ALWAYS RELIABLE.
WHY YOU NEED A DECOUPLER
CP System IsolationPipelines and other cathodically protected structures require efficient CP systems to protect against corrosion. It can be difficult or impossible to provide adequate protection if that system is bonded to unprotected structures or grounding systems, resulting in excessive current demand and inadequate protection voltage. Electrical isolation is accomplished by utilizing Dairyland decouplers which block the flow of DC current to foreign structures, thereby optimizing your CP system’s performance.
Protected structures are now isolated, but also require grounding of induced AC voltage, AC faults, and lightning effects. Dairyland decoupling devices provide simultaneous DC isolation and safety grounding functions to limit voltage on structures. This unique ability to operate in both DC isolation and AC grounding modes provides you with a safely grounded structure while still achieving efficient cathodic protection.
Grounding Electrical Hazards
When CP efficiency and electrical safety have both been addressed, you can know that both personnel and equipment have been truly protected. Dairyland’s solid-state products and accessories are focused on complete protection inherently provided in the highly rated, fail-safe designs. With extensive design experience, third-party product certifications, audited ISO 9001 systems, and technical application expertise freely available, Dairyland is the solutions provider to help users isolate, ground, and protect.
Protect Plant and Personnel
4
PRODUCT QUALITY
We’re passionate about quality. Our extensive product line
features proven engineering methods & design techniques
with extensive product certification ensuring a safe, reliable
product you can trust.
TECHNICAL SUPPORT
We are your resource. Our online technical support
knowledge base includes video training, technical articles
and frequently asked questions and our team of engineers
are ready to assist with your questions and applications.
CUSTOMER SERVICE
Our staff is trained to serve. We know that your time is
valuable and our team is prepared to provide thorough,
accurate assistance to all of your needs.
ALWAYS RELIABLE.
ALWAYS RUGGED.
Dairyland Electrical Industries is the world’s leading manufacturer of solid-state decoupling products most commonly used to
isolate cathodically protected structures from grounding systems or other equipment while simultaneously providing safety
grounding for AC fault current and lightning.
Our solid-state and maintenance-free products feature extensive third party certification, and our company has achieved ISO
9001:2015 certification, implementing robust quality management processes. Our latest certifications position Dairyland to
continue delivering the exceptional product quality and service our customers around the world have come to expect.
• Fail-Safe & Maintenance-Free Products
• Simultaneous CP Isolation & Safety Grounding
• Lightning Protection Rated
• Impeccable Product Performance for More Than 30 Years
• UL, C-UL Certifications for grounding electrical equipment
• UL, C-UL Certifications for hazardous locations
• IECEx, ATEX, EAC Certified
ATEX
5
AC MITIGATION
APPLICABLE PRODUCTS
• Mitigate induced voltage on pipelines in close proximity
to power lines
• Maintain integrity of CP system voltage
• Provide over-voltage protection from AC faults and lightning
SSDDC isolation & AC grounding in a sealed, low-cost package
PCRDC decoupling device with a wide range of ratings
PCRHDC decoupling featuring Div 1/Zone 1 certification
6
SOLID-STATE DECOUPLER (SSD)
Use of the SSD product
line dominates decoupler
applications around the world,
providing DC isolation, AC
continuity and over-voltage
protection. Using proven,
solid-state construction,
and independently certified
to the applicable standards,
the SSD is an affordable,
compact, and highly rated
decoupling device for cathodically
protected structures. With a wide variety of ratings
and mounting arrangements available, the SSD can be applied to most
applications addressed by Dairyland.
Rated for high levels of AC fault current, lightning, and steady-state AC current, the SSD outperforms other technologies
such as metal oxide varistors, gapped arrestors, and polarization cells, and can be used for a wide variety of applications
including AC voltage mitigation, insulated joint protection, decoupling electric equipment and tank grounding systems, and
other situations where it is desirable to isolate DC (CP current) while grounding AC fault current and lightning.
WHY ARE FAULT CURRENT RATINGS IMPORTANT?
Fault current exposure for the Dairyland decoupler relates to the ampacity, proximity, and mode of current transfer from a faulting source (power transmission line, motor circuit, induction from overhead lines, etc.). Selecting a product rating with reasonable margin above the site conditions will provide an unlimited lifetime of service. Contact Dairyland for any assistance with selection of appropriate ratings.
• UL, C-UL Listed for Class I, Division 2 Locations
• IECEx Certified for Zone 2 – UL
• ATEX Certified for Zone 2 – UL/DEMKO
• EAC Certified for Zone Class 2 – NANIO
• Fail-Safe Product Design
• Compact, Lightweight Package
• Hermetically Sealed, Submersible Design
• Standardized Mounting Arrangements
• Higher Blocking Voltage and Lower Leakage than Polarization Cells
• UL, C-UL Listed for Grounding Electrical Equipment
FEATURES
7
• Block facility CP current from reaching power company grounds
• Simple decoupler installation at power company transformer
• Preserves AC bonding for safety
PCRDC decoupling device with a wide range of ratings
DECOUPLING POWER UTILITY GROUNDING SYSTEMS
APPLICABLE PRODUCTS
8
Since 1994, the PCR has been the gold standard
for decoupling products, providing a wide range
of protective ratings to handle abnormal
conditions that can occur on pipeline
and power utility systems. Providing
DC isolation and simultaneous AC
continuity/grounding, the PCR will
enhance cathodic protection system
operation while providing the safety
grounding and bonding needed for
personnel and equipment.
With a blocking voltage higher than
polarization cells, yet much lower and safer
than gapped arresters and metal oxide
varistors, the PCR is the ideal isolation and
grounding product for cathodically protected structures.
Boasting an impeccable safety and operation record, with tens
of thousands installed worldwide, the PCR remains positioned as the
most versatile decoupling product available.
POLARIZATION CELL REPLACEMENT (PCR)
UNDERSTANDING ELECTRICAL GROUNDING SYSTEMS
Electrical grounding systems are necessary for personnel safety and equipment protection, and are required by code, but problems can arise when cathodic protection systems are bonded to grounding systems. Decouplers that are certified for such use can be installed in electrical grounding systems to isolate DC and meet all AC safety codes, but these must be applied correctly. Contact Dairyland or see the website application pages for more guidance.
• UL, C-UL Listed for Class I, Division 2 Locations
• IECEx Certified for Zone 2 – UL
• ATEX Certified for Zone 2 – UL/DEMKO
• EAC Certified for Zone Class 2 – NANIO
• Fail-Safe Design
• Range of AC Fault Ratings Available
• Higher Blocking Voltage and Lower Leakage than Polarization Cells
• Available in Submersible Version
• UL, C-UL Listed for Grounding Electrical Equipment
FEATURES
9
• Prevent unwanted drain of cathodic protection current
• Comply with required AC grounding codes
• Minimal installation effort provides large improvement in CP
DECOUPLING ELECTRIC EQUIPMENT GROUNDING SYSTEMS
APPLICABLE PRODUCTS
DC decoupling device with a wide range of ratings
PCR PCRHDC decoupling featuring Div 1/Zone 1 certification
SSDDC isolation & AC grounding in a sealed, low-cost package
10
Dairyland’s popular PCR device is also available in a
version suitable for addressing Division 1 and Zone
1 (classified) locations: the model PCRH. The PCRH
features the same electrical ratings as the PCR, in
a flameproof package, extending the product line for
use in Division 1 or Zone 1 hazardous locations.
The PCRH has been fully tested and certified
by Underwriter’s Laboratory (UL) to various
international standards, making it the only known
decoupler in the world carrying these markings in a
Class I Division 1 and Zone 1 package.
HOW TO DEFINE A HAZARDOUS LOCATION
Hazardous (Classified) Locations are defined in the US National Electrical Code (NEC), and in other international standards, describing the requirements of electrical products used in these locations. Decisions on the classification of a particular site depend on several factors, including:• Whether ignitable concentrations of flammable gases, vapors, or liquids are considered commonly present (Division 1 or Zone 1) or not typically present (Division 2 or Zone 2)
• The ease of ignition of the material, considering the gas or vapor type (Gas Groups) and the temperature of ignition (Temperature Codes)See the Dairyland website for further education on hazardous locations.
POLARIZATION CELL REPLACEMENT FOR HAZARDOUS LOCATIONS (PCRH)
• ATEX Certified for Zone 1 – UL/DEMKO
• Offered with Optional Customized Conductor Kits
• EAC Certified for Zone Class 1 – NANIO
• Fail-Safe Design
• Range of AC Fault Ratings Available
• UL, C-UL Listed for Class I, Division 1&2 Locations
• UL, C-UL Listed for Grounding Electrical Equipment
• IECEx Certified for Zone 1 – UL
FEATURES
11
• Protect insulated joints from lightning and AC fault damage
• Fail-safe, solid-state design outperforms all other technologies
• Meet military and civilian specifications for protection in hazardous locations
APPLICABLE PRODUCTS
Lightning and AC fault protection in a Div 1/Zone 1 package
Lightning and AC fault protection in Div 2/Zone 2 locations
AIRPORT FUELING SYSTEM PROTECTION
OVP OVP2
12
The OVP product line specializes in over-voltage protection of insulated joints and is the
premier option when lightning or AC fault current is a concern. OVP devices feature a fail-
safe design, with substantial ratings for fault current and lightning surge current.
Outclassing typical gapped arrester designs, which are only rated for lightning, the OVP
uses solid-state construction to conduct at very low voltages, providing the best over-
voltage protection available, and capable of handling substantial lightning and AC fault.
The OVP is a totally unique product, certified for use in Division 1 and
Zone 1 hazardous locations, with flameproof construction. Designed for
rigorous military requirements, the OVP is used at hazardous above- and
below-grade locations. OVP use is intended for sites where induced AC
voltage is not present.
UNDERSTANDING AC FAULTS AND LIGHTNING
Alternating current and lightning waveforms are often confused by users. An AC fault is a high magnitude alternating current (50 or 60 cycles per second) produced during an electrical system malfunction, while a lightning discharge occurs in microseconds during a storm. Lightning can cause spectacular flashovers (arcing) due to its fast rise time, while AC faults are relatively longer duration events that involve significantly more energy. Each causes different effects, so visit the Dairyland website to learn more about these phenomena.
OVER-VOLTAGE PROTECTOR (OVP)
• UL, C-UL Listed for Class I, Division 1&2 Locations
• IECEx Certified for Zone 1 – UL
• ATEX Certified for Zone 1 – UL/DEMKO
• EAC Certified for Zone Class 1 – NANIO
• Fail-Safe Construction
• Solid-State Design Eliminates Arcing
• Meets US Army Corp of Engineers Specification for Fueling Systems
• Rated for Both AC Fault and Lightning Current
• Suitable for Submersed or Above-Grade Locations
FEATURES
13
• Protect insulated joints from lightning and AC fault damage
• Fail-safe, solid-state design outperforms all other technologies
• Certified products for hazardous locations
Lightning and AC fault protection in a Div 1/Zone 1 package
Lightning and AC fault protection in Div 2/Zone 2 locations
DC isolation & AC grounding in a sealed, low-cost package
APPLICABLE PRODUCTS
INSULATED JOINT PROTECTION
OVP2DC decoupling device with a wide range of ratings
PCR SSD OVPDC decoupling fea-turing Div 1/Zone 1 certification
PCRH
14
Like its predecessor, the OVP, the OVP2 features
fail-safe construction, as well as high fault and
lightning current ratings to provide the best over-
voltage protection available. The OVP2 features a
hermetically sealed enclosure for sites classified
as Division 2, Zone 2, or ordinary locations and
has the same conservative design and features
of the OVP, but in a lighter weight and lower cost
package.
Unlike “arrester” type products, the OVP2 is a
solid-state switching device with full ratings for
AC fault current and high levels of lightning surge
current. Protection occurs at a much lower and safer
voltage, providing years of reliable service. OVP2 use is
intended for sites where induced AC voltage is not present.
WHY IS CONDUCTOR LENGTH IMPORTANT?
For fast rising currents, such as from lightning, over-voltage protection is greatly affected by the proximity of the device relative to an insulated joint or other structure being protected. This effect is independent of the protective device being used, as it is mainly due to the inductance properties of the conductor that increase with length. If this voltage is in excess of the insulation or coating strength, arcing will occur. Use bus bar mounting kits by Dairyland to best limit voltage.
OVER-VOLTAGE PROTECTOR 2 (OVP2)
FEATURES
• IECEx Certified for Zone 2 – UL
• ATEX Certified for Zone 2 – UL/DEMKO
• Corrosion-free, Lightweight Molded Housing
• EAC Certified for Zone Class 2 – NANIO
• Fail-Safe Construction
• Solid-State Design Eliminates Arcing
• Meets US Army Corp of Engineers Specification for Fueling Systems
• Rated for Both AC Fault and Lightning Current
• Suitable for Submersed or Above-Grade Locations
• UL, C-UL Listed for Class I, Division 2 Locations
15
Engineered Gradient Control Mats to limit touch and step potentials
DC isolation & AC grounding in a sealed, low-cost package
• Limit step and touch voltage near pipelines
• Grid-type mat outperforms other mat designs
• Interaction of the mat and CP system is eliminated when decoupled
GRADIENT CONTROL MATS AND DECOUPLING
APPLICABLE PRODUCTS
GCM SSD
16
Personnel working near pipelines can be subject to electrical
hazards such as lightning, AC fault current/voltage, and
steady-state AC induction. “Ground mats” have typically
been used at above ground pipeline structures where these
hazards exist, but past designs do not provide adequate
protection against lightning conditions.
Dairyland offers engineered Gradient Control Mats (GCM)
to address lightning and AC fault current conditions,
backed by analysis from experts in lightning protection
and cathodic protection guidelines. Step and touch
potentials are now limited with the Dairyland grid-
type mat, in a much lower cost design. Dairyland
also recommends decoupling gradient control
mats to improve CP on the pipeline, and offers the
affordable Solid-State Decoupler (SSD) line for use
in conjunction with the Gradient Control Mat.
ADVANTAGES OF MAT DECOUPLING
Dairyland recommends decoupling gradient control mats to improve CP on the pipeline. Decoupling mats using the SSD allows for several distinct advantages including:• The galvanic potential of the mat material has no effect upon pipeline CP• Pipeline CP readings can be taken in the vicinity of the mat• The life of the anodes used to protect the mat is significantly increased
GRADIENT CONTROL MATS (GCM)
• Decoupling the Mat Offers Long Life and Improved CP on the Pipeline
• Data Available on Design Life and Supplemental Anodes
• Low Cost Design
• Fast Construction Using 4ft x 8ft Sheets and Exothermic Welding
• Low Inductance Design Limits Step and Touch Potentials Due to Lightning
FEATURES
17
• Isolate CP from copper substation grounding systems
• Provide over-voltage protection for sheath or pipe
• Ground high transmission fault current values effectively
DC decoupling with ratings appropriate for power transmission systems
POWER CABLE SHEATH DECOUPLING
APPLICABLE PRODUCTS
ISP
18
The ISP is the original solid-state AC conducting/DC blocking
device designed for the corrosion prevention industry. The ISP
product line features the most flexible and wide range of product
ratings and applications available to the market. Additionally,
the ISP provides the highest levels of AC fault-
handling capability - up to the highest typical
transmission system faults. With its
design features and ratings, the ISP
is the preferred device for power utility
underground cable decoupling/bonding
requirements.
Comprehensive in-service
testing of the ISP is possible
using the ISP Tester accessory,
a sophisticated yet automated
field test device that verifies all
major ISP functions.
FAIL-SAFE CONSTRUCTION IMPORTANCE
A key design feature of all Dairyland products is the fail-safe nature of the devices. Simply stated, if the device is exposed to current and time beyond the rating of the device, it is designed to fail as a short circuit, continuing to provide over-voltage protection to the structure. In this mode, it is still fully capable of handling the rated lightning or fault current, but will not block CP current. Assured safety grounding is key, and you can’t have “safety” without “fail-safe.”
ISOLATOR/SURGE PROTECTOR (ISP)
• Solid-state Design Replaces Polarization Cell Technology
• No Maintenance Needed
• Fail-safe Design
• Self-protection Features Built-in
• Simple Field Testing Procedures
• Comprehensive Testing Available with Optional ISP Tester
• Flashing LED Indicates Device Operation
• No Energy/Power Requirements
• Submersible or Non-submersible Enclosure
FEATURES
19
APPLICABLE PRODUCTS
DECOUPLING TANK GROUNDING SYSTEMS
• Isolate cathodically protected tanks from local tank grounds and other structures
• Comply with required safety codes for an effective grounding path
• Dramatically improve CP system performance
• Maintain lightning and AC fault protection on tanks
Lightning and AC fault protection in Div 2/Zone 2 locations
OVP2DC decoupling device with a wide range of ratings
PCRDC isolation & AC grounding in a sealed, low-cost package
SSDLightning and AC fault protection in a Div 1/Zone 1 package
OVPDC decoupling featuring Div 1/Zone 1 certification
PCRH
20
Rectifiers that serve cathodically protected
structures, such as pipelines, can be
subject to various field effects that pose a
hazard to maintenance staff. Pipelines near
high voltage power transmission structures
may have magnetically induced alternat-
ing current and voltage affect the pipeline,
which can translate back to the recti-
fier, causing risks for personnel. Pipeline
measurements during surveys can also be
influenced due to AC induction applied to
the rectifier. The Dairyland Rectifier Discon-
nect Switch is a compact and safe pull-
style switch to separate rectifier DC output
from field connections to address these
problems.
• Rated for Rectifier Output Through 100A
• UL, C-UL Listed Switch Design
• Contacts Enclosed During Switching
• No Arc Exposure
• Clearly Labeled Switch Positions Indicate Rectifier Status
FEATURES
PRODUCT CERTIFICATIONS
Dairyland has obtained numerous product certifications from various independent testing laboratories around the world. Independent verification of our product performance is a valuable indicator of the Dairyland philosophy of providing the highest product quality to the energy industry. Personnel and public are well served by Dairyland products that provide electrical safety to extensive infrastructure around the world.
21
RECTIFIER DISCONNECT SWITCH
WHY DISCONNECT DECOUPLERS?
Decouplers perform safety functions, such as collapsing induced AC voltage on pipelines that is caused by overhead power line influence, and decoupler disconnection could expose workers to arcs and increased AC voltage. Dairyland Isolation Switches allow for safe disconnection. Decouplers will appear as a low impedance to pipe locating signals requiring disconnection local to the test. Other reasons for disconnection can include system testing, or to overcome capacitive effects during close interval surveys.
22
• Safe Decoupler Disconnection in Seconds
• No Exposed Arcing or Contacts
• Enhances Field Testing and Surveying Options
• AC Fault-rated to Match Decouplers
• Available in Pedestal Mounted and Enclosure Mounted Options
• SWX-100-PED, SWX-100-INT, Mounted to the Exterior or Interior
of any Dairyland Mounting Pedestal
• SWX-100-ENCL, Mounted Inside a Dairyland Enclosure With
Any Model SSD or PCR
SWX-100-PED
The updated SWX-100-PED decoupler isolation switch
features an improved dead-front design and added jacks for
easy connection for testing and locating.
SWX-100-ENCL
SWX-100-ENCL models accomodate a pull
style isolation switch and any Dairyland decoupler
bundled in a NEMA 4x enclosure.
SWX-100-INT
Utilizing the same switch technology that has become
popular amongst Dairyland customers, the SWX-100-INT kit
allows users to locate the isolation switch inside a padlock-
able MTP-36 pedestal.
SWX-100-INT48
The SWX-100-INT48 switch kit includes a pullstyle
isolation switch and components needed to connect
with any Dairyland decoupler for field installation inside
Dairyland’s MTP-48 pedestal.23
MTM MOUNTING KIT Used for mounting SSD decouplers and OVP2 over
voltage protectors across monolithic isolation joints.
Construction provides excellent over
for lightning and ac faults.
MTF KITFlange Mount Bracket for
SSD and OVP2
ACL-18 ORRACL-18PCRH Conductor Kit
Suitable for use with: PCRH
MTG-OVP2General Purpose OVP2
Mounting Bracket
MTL KITConductor Kit
Suitable for use with: PCR, SSD, OVP2
DENSO LT TAPELow Temperature Petrolatum
Tape
Suitable for use with: GCM
HORIZONTALFLANGE MOUNTFlange Mounting for PCR
on Horizontal Flanges
HCNHex Coupling Nut for Pin
Brazed Mounting of SSD
PMK KITMounting Stand for
Decouplers
TERMINAL EXTENSION KITAccomodate multiple
conductors to decoupler
terminals
Suitable for use with: SSD, OVP2, PCR
AP KITAdapter Plate Kit for Flange
Attachment of Cables
MTT KITFlange Mounting Bracket
for SSD or OVP2 Using
Drilled/Tapped Holes
ACCESSORIES
24 FOR FULL INFORMATION ON ALL OF OUR ACCESSORIES VISIT OUR WEBSITE A
MTM MOUNTING KIT Used for mounting SSD
decouplers and OVP2
over-voltage protec-
tors across monolithic
isolation joints.
Used for mounting SSD decouplers and OVP2 over-
oss monolithic isolation joints.
ovides excellent over-voltage protection
for lightning and ac faults.
MTP-48 MOUNTING PEDESTAL By customer request, this spacious 48” pedestal features
robust construction with a removable and padlockable lid.
Huge insulated backplane allows extensive mounting area
for equipment.
FMWHB KITFlange Mounting Kit for
OVP Using Welded Hex
Bolts
UFBUniversal Flange Mounting
Bracket for PCR
ISPTESTERAutomated ISP Testing
in the Field
MOLD-6XThermit Welding Mold for
Gradient Control MatsMTC-38Tubing Clamp Kit
Suitable for use with: OVP, OVP2, PCR, SSD
MTP-3636” Pedestal
for PCR, SSD
FMFB KITFlange Mounting Kit for OVP
Using Flange Bolts
FMTH KITFlange Mounting Kit for OVP
Using Tapped Holes
MTS KITFlange Mounting Bracket
for SSD and OVP2 Using
Pin Brazed Studs
WTM-SWeld Tab Mounting Kit
VAULTDecoupler Mounting
Below Grade
SORIES VISIT OUR WEBSITE AT WWW.DAIRYLAND.COM/ACCESSORIES 25
MTP-4848” Pedestal
for PCR, SSD.
PCR - RATINGS
Threshold Voltage-3/+1V (standard)
-2/+2V (optional)
-4/+1V (optional)
-6/+1V (optional)
PCRH - RATINGS
Threshold Voltage-3/+1V (standard)
-2/+2V (optional)
SSD - RATINGS
Threshold Voltage-2/+2V (standard)
-3/+1V (optional)
AC Steady-State Current (amperes - rms) 50/60Hz45A (standard)
80A (optional)
AC Steady-State Current (amperes - rms) 50/60Hz45A (standard)
AC Steady-State Current (amperes - rms)
50/60Hz45A (standard)
AC Fault Current (amperes-rms) 60Hz
Model 1 cycle 3 cycles 10 cycles 30 cycles3.7KA 6,500 5,000 4,200 3,700
5KA 8,800 6,800 5,700 5,000
10KA 20,000 15,000 12,000 10,000
15KA 35,000 27,000 21,000 15,000
Example Model Number: PCR-3.7KA
AC Fault Current (amperes-rms) 60Hz
Model 1 cycle 3 cycles 10 cycles 30 cycles3.7KA 6,500 5,000 4,200 3,700
5KA 8,800 6,800 5,700 5,000
10KA 20,000 15,000 12,000 10,000
15KA 35,000 27,000 21,000 15,000
Example Model Number: PCRH-3.7KA-BCD
AC Fault Current (amperes-rms) 50/60Hz
Model 1 cycle 3 cycles 10 cycles 30 cycles1.2KA 2,100 1,600 1,400 1,200
2.0KA 5,300 4,500 3,700 2,000
3.7KA 6,500 5,000 4,200 3,700
5.0KA 8,800 6,800 5,700 5,000
Example Model Number: SSD-2/2-3.7-100-R
AC Fault Current (amperes-rms) 50Hz
1 cycle 3 cycles 10 cycles 30 cycles 6,500 5,000 4,200 3,700
8,800 6,800 5,700 5,000
19,000 14,000 11,000 9,000
33,000 25,000 19,000 14,000
AC Fault Current (amperes-rms) 50Hz
1 cycle 3 cycles 10 cycles 30 cycles 6,500 5,000 4,200 3,700
8,800 6,800 5,700 5,000
19,000 14,000 11,000 9,000
33,000 25,000 19,000 14,000
Lightning Surge Current100kA crest (8 x 20 µs waveform)
Lightning Surge Current100kA crest (8 x 20 µs waveform)
Lightning Surge Current100kA crest (4 x 10 µs waveform) for 5.0KA, 3.7KA and
2.0KA models
75kA crest (4 x 10 µs waveform) for 1.2KA models
Environmental Rating:NEMA 4X, IP66 (standard)NEMA 6P (optional)
Environmental Rating:NEMA 4, IP66
Environmental Rating:IP68 - Submersible
(to 2m depth)
Hazardous (classified) areasPer NEC, CSA: Class I, Division 2, Groups A, B, C, DPer ATEX, IECEX, EAC: Zone 2, Group IIC
Hazardous (classified) areasPer NEC, CSA: Class I, Division 1 & 2, Groups B, C, DPer ATEX, IECEX, EAC: Zone 1, Group IIB
Hazardous (classified) areasPer NEC, CSA: Class I, Division 2, Groups A, B, C, DPer ATEX, IECEX, EAC: Zone 2, Group IIC
Third-party listings and approvals:UL, C-UL, UL/DEMKO, NANIO
Third-party listings and approvals:UL, C-UL, UL/DEMKO, NANIO
Third-party listings and approvals:UL, C-UL, UL/DEMKO, NANIO
26
OVP - RATINGS
Threshold Voltage-3/+1V (standard)
-2/+2V (standard)
Up to -4/+4V (optional)
OVP2 - RATINGS
Threshold Voltage-2/+2V (standard)
-3/+1V (optional)
ISP - RATINGS
The ISP has numerous ratings combinations possible–reference the technical literature for more information.Ranges shown here for brevity.
AC Steady-State Current (amperes - rms)to 90A
AC Fault Current (amperes-rms) 50/60 Hz
1 cycle 3 cycles 10 cycles 30 cycles 6,500 5,000 4,200 3,700
Example Model Number: OVP-3/1-3.7-100
AC Fault Current (amperes-rms) 50Hz/60Hz
Model 1 cycle 3 cycles 10 cycles 30 cycles1.2KA 2,100 1,600 1,400 1,200
2.0KA 5,300 4,500 3,700 2,000
3.7KA 6,500 5,000 4,200 3,700
5.0KA 8,800 6,800 5,700 5,000
Example Model Number: OVP2-2/2-3.7-100
AC Fault Current (amperes-rms)to approx. 100kA
Lightning Surge Current100kA crest (8 x 20 µs waveform)
Lightning Surge Current100kA crest (4 x 10 µs waveform) for 5.0KA, 3.7KA and 2.0KA models
75kA crest (4 x 10 µs waveform) for 1.2KA models
Lightning Surge Currentto 100kA peak, 8 x 20µs waveform
Environmental Rating:NEMA 6P, IP68
Environmental Rating:IP68 - Submersible (to 2m
depth)
Hazardous (classified) areasPer NEC, CSA: Class I, Division 1 & 2, Groups B, C, DPer ATEX, IECEX, EAC: Zone 1, Group IIB + H2
Hazardous (classified) areasPer NEC, CSA: Class I, Division 2, Groups A, B, C, DPer ATEX, IECEX, EAC: Zone 2, Group IIC
Third-party listings and approvals:UL, C-UL, UL/DEMKO, NANIO
Third-party listings and approvals:UL, C-UL, UL/DEMKO, NANIO
Threshold Voltageto 20V
Questions?
Find out more about our products and services at www.dairyland.com
or contact us directly: Phone: 608-877-9900 Email: [email protected]
27