ERV D / HRV DERV EC D / HRV EC D
Heat and Energy Recovery Ventilators
2 AIR HANDLING UNITS |2017-11 |www.blauberg.us
3www.blauberg-group.com
CONTENT
ERV D(R) 80 6
HRV D / ERV D series overview 4
HRV D(R) 120 / ERV D(R) 120 10
HRV D(R) 150 / ERV D(R) 150 16
ERV EC D(R) 80 22
HRV EC D(R) 120 / ERV EC D(R) 120 26
HRV EC D(R) 150 / ERV EC D(R) 150 32
S50 – 20/40/60 push button timer 38
4 AIR HANDLING UNITS |2017-11 |www.blauberg.us
HRV D / ERV D series
ERV D 80
ERV DR 80
ERV EC D 80
ERV EC DR 80
ERV D 120
ERV DR 120
ERV EC D 120
ERV EC DR 120
Core
ERV ERV
Motor
Airflow @ 0.1 in. W. G. 74 CFM 88 CFM 136 CFM 176 CFM
Max. CFM/W 0.99 1.72 0.84 2.86
Sensible Recovery Efficiency
at 32°F (0°C)
69 73 63 66
Defrost system Fan defrost Recirculation Fan defrost Recirculation Fan defrost Recirculation Fan defrost Recirculation
Build incontrol
board with independent
fan speed adjustment 0%-
100%
+ + + + + + + +
Slim casing design 8 7/16” 9 1/16”
5www.blauberg-group.com
HRV D / ERV D series
HRV D 120
HRV DR 120
HRV EC D 120
HRV EC DR 120
ERV D 150
ERV DR 150
ERV EC D 150
ERV ECDR 150
HRV D 150
HRV DR 150
HRV EC D 150
HRV EC DR 150
Core
HRV ERV HRV
Motor
Airflow @ 0.1 in. W. G. 136 CFM 176 CFM 161 CFM 181 CFM 161 CFM 181 CFM
Max. CFM/W 0.84 2.86 1.00 2.56 1.00 2.56
Sensible Recovery Efficiency
at 32°F (0°C)
60 62 67 73 64 69
Defrost system
Fan defrost
Recircula-tion
Fan defrost
Recircula-tion
Fan defrost
Recircula-tion
Fan defrost
Recircula-tion
Fan defrost
Recircula-tion
Fan defrost
Recircula-tion
Build incontrol
board with independent
fan speed adjustment 0%-100%
+ + + + + + + + + + + +
Slim casing design 9 1/16” 9 1/8”
6 AIR HANDLING UNITS |2017-11 |www.blauberg.us
Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
• 74 CFM airflow rate provides effective ventilation in apartment overcoming high pressure in condo tower duct systems.
• Cross flow core ensures up to 69% SRE.• Slim casing design (8 7/16”) is perfect for in-ceiling installation.• Build in control board enables Supply and Exhaust fan inde-
pendent speed adjustment from 0 to 100% right at the job side.• Fast and simple mounting process thanks to brackets system.• Automatic recirculation damper (R option) for effective cold
protection.• No drain needed (ERV).
Steel casing is covered with high-quality multilayer alu-minium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
CASING
DESCRIPTION
FILTERWashable MERV 6 air filters in exhaust and supply air streams.Optional supply: anti grease aluminum filter.
Defrost system is activated when the outdoor temperature falls below 23° F (-5° C).Recirculation defrost ERV DR 80.Fan stop defrost ERV D 80.
DEFROST SYSTEM
The unit is equipped with supply and exhaust centrifugal fans with backward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and impellers are dynamically balanced.
FANS
The unit incorporates an integrated automation and control system with following functions: • Operation mode switch.• Airflow balancing enabled by supply and exhaust fan in-
dependent speed adjustment from 0 to 100% (percent-age is displayed on built in screen).
• Automatic recovery core frost protection.• External control device connection (up to 5 at the same
time).
CONTROL
5 year warrantyWARRANTY
ERV D 80 ERV DR 80
Backdraft Dampers ClampsAir disk valve
ACCESSORIES
Timer
Enthalpic core (ERV D(R) 80) provides both heat&humi-dity recovery. For enthalpic core no drain required.
HEAT RECOVERY CORE
7www.blauberg-group.com
ERV D 80 ERV DR 80
ENERGY RECOVERY VENTILATION
Due to low height of the casing the units offer perfect solution for the false ceiling installation in limited space.Brackets system makes mounting process easy and fast.
MOUNTING
Step 1 Step 2 Step 3
H
H = 8 7/16”
8 AIR HANDLING UNITS |2017-11 |www.blauberg.us
ERV D 80 ERV DR 80
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 35 74 37 78 37 78 7450 0.2 31 66 32 68 33 70 7475 0.3 26 56 27 57 28 59 74
100 0.4 22 46 22 47 23 49 74125 0.5 17 36 17 36 18 38 74150 0.6 11 24 12 25 12 25 73175 0.7 6 12 6 13 6 13 73200 0.8 2 4 1 2 2 4 72
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 20 42 43 69 82 0.46
II 0 32 25 54 55 66 78 0.46
III 0 32 30 63 67 66 78 0.44
IV
V -25 -13 20 42
Total Recovery Efficiency
Cooling VI 35 95 20 42 42.6 46.1 71.9 0.49
Model Volts Max. Watts Max. Amps
ERV D(R) 80 120V, 60Hz 74 0.6
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0 10 20 30 40 50 60 70 80 90
Ext.
Di�
eren
tial P
ress
ure
- in.
WG
Gross Airow - CFM
SupplyExhaust
Extract air
Supply airExhaust air
Intake air
PERFORMANCE
9www.blauberg-group.com
ERV DR 80
ERV D 80
Ø 4 7/8”
Ø 4 7/8”
4 1/16”
4 1/2” 29 13/16”
26”
21 15/16” 8 7/16” 4 7/16”
8 7/16” 4 7/16”
3 7/8 ”
3 7/8 ”
9 1/2 ”
9 1/2 ”
20 3/
16”
20 3/
16”
18 1/16”
9 1/2 ”
17 1/
16”
17 1/
16”
9 1/2 ”
Ø 4 7/8”
Ø 4 7/8”
4 1/16”
4 1/2” 29 13/16”
26”
21 15/16” 8 7/16” 4 7/16”
8 7/16” 4 7/16”
3 7/8 ”
3 7/8 ”
9 1/2 ”
9 1/2 ”
20 3/
16”
20 3/
16”
18 1/16”
9 1/2 ”
17 1/
16”
17 1/
16”
9 1/2 ”
ERV D 80 ERV DR 80
ENERGY RECOVERY VENTILATION
DIMENSIONS
10 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
• 142 CFM airflow rate provides effective ventilation in apartment overcoming high pressure in condo tower duct systems.
• Cross flow core ensures up to 63% SRE.• Slim casing design (9 1/16”) is perfect for in-ceiling installation.• Build in control board enables Supply and Exhaust fan inde-
pendent speed adjustment from 0 to 100% right at the job side.• Fast and simple mounting process thanks to brackets system.• Automatic recirculation damper (R option) for effective cold
protection.• No drain needed (ERV).
Steel casing is covered with high-quality multilayer alu-minium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
CASING
DESCRIPTION
FILTERWashable MERV 6 air filters in exhaust and supply air streams.Optional supply: anti grease aluminum filter.
Defrost system is activated when the outdoor temperature falls below 23° F (-5° C).Recirculation defrost HRV/ERV DR 120.Fan stop defrost HRV/ERV D 120.
DEFROST SYSTEM
The unit is equipped with supply and exhaust centrifugal fans with forward curved blades and build-in thermal over-heating protection with automatic restart. The electric mo-tors and impellers are dynamically balanced.
FANS
The unit incorporates an integrated automation and control system with following functions: • Operation mode switch.• Airflow balancing enabled by supply and exhaust fan inde-
pendent speed adjustment from 0 to 100% (percentage is displayed on built in screen).
• Automatic recovery core frost protection.• External control device connection (up to 5 at the same time).
CONTROL
5 year warrantyWARRANTY
Backdraft Dampers ClampsAir disk valve
ACCESSORIES
Timer
Aluminum cross-flow core (HRV D(R) 120) ensures efficient heat recovery.
Enthalpic core (ERV D(R) 120) provides both heat&humidity recovery. For enthalpic core no drain required.
HEAT RECOVERY CORE
HRV D(R) 120 ERV D(R) 120
11www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATION
Due to low height of the casing the units offer perfect solution for the false ceiling installation in limited space.Brackets system makes mounting process easy and fast.
MOUNTING
Step 1 Step 2 Step 3
H
H = 9 1/16”
HRV D(R) 120 ERV D(R) 120
12 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 63 134 66 140 64 136 15650 0.2 61 130 64 136 62 131 15575 0.3 60 128 63 133 61 129 153
100 0.4 59 124 61 129 58 123 152125 0.5 56 118 58 123 56 119 151150 0.6 53 112 55 117 54 114 149175 0.7 50 106 52 110 52 110 147200 0.8 48 102 50 106 49 104 146225 0.9 46 98 48 102 47 100 145250 1 44 94 46 97 43 91 143275 1.1 39 83 41 87 38 81 140300 1.2 32 67 33 70 31 66 135325 1.3 22 47 23 49 21 44 130350 1.4 13 28 14 30 13 28 127375 1.5 7 14 5 11 7 15 126
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 30 64 85 63 74 0.42
II 0 32 45 95 114 60 70 0.36
III 0 32 50 106 128 59 69 0.34
IV
V -25 -13 31 65 89 44 48 0.37
Total Recovery Efficiency
Cooling VI 35 95 30 64 85 40 62 0.34
Model Volts Max. Watts Max. Amps
ERV D(R) 120 120V, 60Hz 156 1.3
HRV D(R) 120 ERV D(R) 120
PERFORMANCE ERV D(R) 120
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 20 40 60 80 100 120 140 160
SupplyExhaust
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 20 40 60 80 100 120 140 160
SupplyExhaust
Extract air
Supply airExhaust air
Intake air
13www.blauberg-group.com
HRV D(R) 120 ERV D(R) 120
HEAT AND ENERGY RECOVERY VENTILATION
PERFORMANCE HRV D(R) 120
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 67 142 69 146 64 136 15850 0.2 65 138 67 142 62 131 15775 0.3 63 134 65 138 60 127 156
100 0.4 62 132 64 136 58 123 155125 0.5 60 127 62 131 56 119 153150 0.6 58 123 60 127 54 114 152175 0.7 56 119 58 123 52 110 151200 0.8 53 113 55 117 50 106 149225 0.9 51 109 53 112 47 100 148250 1 48 101 49 104 44 93 146275 1.1 44 92 45 95 40 85 143300 1.2 40 84 41 87 34 72 141325 1.3 30 64 31 66 26 55 135350 1.4 17 37 18 38 15 32 130375 1.5 10 21 10 21 8 17 128
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 30 64 86 60 70 0.05
II 0 32 45 95 114 57 67 0.04
III 0 32 50 106 126 55 65 0.04
IV
V -25 -13 31 65 85 60 64 0.03
Total Recovery Efficiency
Cooling VI 35 95 30 64 86 29 61 0.04
Model Volts Max. Watts Max. Amps
HRV D(R) 120 120V, 60Hz 156 1.3
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 20 40 60 80 100 120 140 160
SupplyExhaust
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 20 40 60 80 100 120 140 160
SupplyExhaust
14 AIR HANDLING UNITS |2017-11 |www.blauberg.us
DIMENSIONS
HRV DR 120 | ERV DR 120
HRV D 120 | ERV D 120
3 3/4” 12 3/
8 ”
5 13/16”
5 13/16” 34 7/8” 30 15/16”
12 3/
8 ”
20 1/
16”
3/4”
20 1/
16”
26 3/8” 22 7/16”
Ø 4 7/8” 1 1/8”
1 7/16” 12 5/
8 ” 23
1/4 ”
9 1/16” 3 9/
16”
3 9/16
” 3 15/16”
9 1/16” 3 15/16”
12 5/
18”
23 1/
4 ”
Ø 4 7/8”
3 3/4” 12 3/
8 ”
5 13/16”
5 13/16” 34 7/8” 30 15/16”
12 3/
8 ”
20 1/
16”
3/4”
20 1/
16”
26 3/8” 22 7/16”
Ø 4 7/8” 1 1/8”
1 7/16” 12 5/
8 ” 23
1/4 ”
9 1/16”
3 9/16
” 3 9/
16”
3 15/16”
9 1/16” 3 15/16”
12 5/
18”
23 1/
4 ”
Ø 4 7/8”
HRV D(R) 120 ERV D(R) 120
15www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATIONHRV D(R) 120 ERV D(R) 120
16 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
• 161 CFM airflow rate provides effective ventilation in apartment overcoming high pressure in condo tower duct systems.
• Cross flow core ensures up to 67% SRE.• Slim casing design (9 1/8”) is perfect for in-ceiling installation.• Build in control board enables Supply and Exhaust fan inde-
pendent speed adjustment from 0 to 100% right at the job side.• Fast and simple mounting process thanks to brackets system.• Automatic recirculation damper (R option) for effective cold
protection.• No drain needed (ERV).
Steel casing is covered with high-quality multilayer alu-minium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
CASING
DESCRIPTION
FILTERWashable MERV 6 air filters in exhaust and supply air streams.Optional supply: anti grease aluminum filter.
Defrost system is activated when the outdoor temperature falls below 23° F (-5° C).Recirculation defrost HRV/ERV DR 150.Fan stop defrost HRV/ERV D 150.
DEFROST SYSTEM
The unit is equipped with supply and exhaust centrifugal fans with backward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and impellers are dynamically balanced.
FANS
The unit incorporates an integrated automation and control system with following functions:• Operation mode switch.• Airflow balancing enabled by supply and exhaust fan inde-
pendent speed adjustment from 0 to 100% (percentage is displayed on built in screen).
• Automatic recovery core frost protection.• External control device connection (up to 5 at the same time).
CONTROL
5 year warrantyWARRANTY
HRV D(R) 150 ERV D(R) 150
Backdraft Dampers ClampsAir disk valve
ACCESSORIES
Timer
Aluminum cross-flow core (HRV D(R) 150) ensures efficient heat recovery.
Enthalpic core (ERV D(R)150) provides both heat&humidity recovery. For enthalpic core no drain required.`
HEAT RECOVERY CORE
17www.blauberg-group.com
HRV D(R) 150 ERV D(R) 150
HEAT AND ENERGY RECOVERY VENTILATION
Due to low height of the casing the units offer perfect solution for the false ceiling installation in limited space.Brackets system makes mounting process easy and fast.
MOUNTING
Step 1 Step 2 Step 3
H
H = 9 1/8”
18 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 72 152 74 157 70 149 19250 0.2 68 144 70 148 66 140 19275 0.3 65 137 67 141 63 132 191
100 0.4 60 127 62 131 59 125 191125 0.5 56 119 58 123 55 117 190150 0.6 52 111 54 114 51 108 190175 0.7 48 102 50 105 47 100 189200 0.8 44 93 45 96 43 90 188225 0.9 36 77 40 85 38 79 187250 1 32 67 35 74 33 69 185275 1.1 27 57 30 64 28 59 184300 1.2 22 46 25 53 23 48 183325 1.3 17 35 20 42 17 36 181350 1.4 12 24 15 32 12 25 179375 1.5 6 13 10 21 7 14 178400 1.6 1 2 5 10 1 2 176
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 30 64 67 67 83 0.47
II 0 32 45 94 64 64 78 0.38
III 0 32 50 105 62 62 76 0.36
IV
V -25 -13 31 65 44 44 48 0.37
Total Recovery Efficiency
Cooling VI 35 95 31 65 101 41.5 68 0.42
Model Volts Max. Watts Max. Amps
ERV D(R) 150 120V, 60Hz 192 1.6
PERFORMANCE ERV D(R) 150
Extract air
Supply airExhaust air
Intake air
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
0 20 40 60 80 100 120 140 160 180
SupplyExhaust
HRV D(R) 150 ERV D(R) 150
19www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATION
PERFORMANCE HRV D(R) 150
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 76 161 79 166 71 149 19250 0.2 73 154 75 159 67 142 19275 0.3 68 145 71 149 64 135 191
100 0.4 65 137 67 141 60 127 191125 0.5 60 127 62 131 56 119 191150 0.6 56 119 58 123 52 110 190175 0.7 52 110 54 113 48 102 189200 0.8 48 101 49 104 44 93 188225 0.9 38 81 44 93 40 84 187250 1 34 72 39 83 35 74 186275 1.1 29 62 34 71 31 65 185300 1.2 25 52 28 59 26 54 183325 1.3 19 41 23 48 20 42 181350 1.4 13 29 18 37 14 30 179375 1.5 8 17 12 25 9 18 177400 1.6 3 6 7 15 3 6 176
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 31 65 97 64 79 0.05
II 0 32 44 94 124 62 76 0.05
III 0 32 49 104 134 60 74 0.05
IV
V -25 -13 31 65 85 60 64 0.03
Total Recovery Efficiency
Cooling VI 35 95 30 64 97 31.1 64 0.04
Model Volts Max. Watts Max. Amps
HRV D(R) 150 120V, 60Hz 192 1.6
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
0 20 40 60 80 100 120 140 160 180
SupplyExhaust
HRV D(R) 150 ERV D(R) 150
20 AIR HANDLING UNITS |2017-11 |www.blauberg.us
DIMENSIONS
HRV DR 150 | ERV DR 150
HRV D 150 | ERV D 150
11 13
/16 ”
21 9/
16”
4 5/8”
4 5/8” 9 1/8”
9 1/8”
11 13
/16 ”
2 9/16
”
27 3/4” 31 11/16”
36 1/8” 40 ”
11 13
/16 ”
11 13
/16 ”
25 3/
16”
25 3/
16”
4 5/8”
4 5/8”
Ø 4 7/8”
Ø 4 7/8”
11 13
/16 ”
21 9/
16”
4 5/8”
4 5/8” 9 1/8”
9 1/8”
11 13
/16 ”
2 9/16
”
27 3/4” 31 11/16”
36 1/8” 40 ”
11 13
/16 ”
11 13
/16 ”
25 3/
16”
25 3/
16”
4 5/8”
4 5/8”
Ø 4 7/8”
Ø 4 7/8”
HRV D(R) 150 ERV D(R) 150
21www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATIONHRV D(R) 150 ERV D(R) 150
22 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
• 81 CFM airflow rate provides effective ventilation in apartment overcoming high pressure in condo tower duct systems.
• Cross flow core ensures up to 73% SRE.• Slim casing design (8 7/16”) is perfect for in-ceiling installation.• Build in control board enables Supply and Exhaust fan inde-
pendent speed adjustment from 0 to 100% right at the job side.• Fast and simple mounting process thanks to brackets system.• Automatic recirculation damper (R option) for effective cold
protection.• No drain needed (ERV).• Up to 1.72 CFM/W (Energy Star requirement — 1.2 CFM/W).
Steel casing is covered with high-quality multilayer alu-minium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
CASING
DESCRIPTION
FILTERWashable MERV 6 air filters in exhaust and supply air streams.Optional supply: anti grease aluminum filter.
Defrost system is activated when the outdoor temperature falls below 3° F (-5° C).Recirculation defrost ERV EC D(R) 80.Fan stop defrost ERV EC D80.
DEFROST SYSTEM
High efficient electronically commutated motors with ex-ternal motor and impeller with backward curved blades. EC motors are featured with high performance and total speed controllable range. The electric motors and impellers are dy-namically balanced.
FANS
The unit incorporates an integrated automation and control system with following functions: • Operation mode switch.• Airflow balancing enabled by supply and exhaust fan in-
dependent speed adjustment from 0 to 100% (percent-age is displayed on built in screen).
• Automatic recovery core frost protection.• External control device connection (up to 5 at the same
time).
CONTROL
5 year warrantyWARRANTY
ERV EC D 80ERV EC DR 80
Backdraft Dampers ClampsAir disk valve
ACCESSORIES
Timer
Enthalpic core (ERV EC D(R) 80) provides both heat&humidity recovery. For enthalpic core no drain required.
HEAT RECOVERY CORE
23www.blauberg-group.com
ERV EC D 80ERV EC DR 80
ENERGY RECOVERY VENTILATION
Due to low height of the casing the units offer perfect solution for the false ceiling installation in limited space.Brackets system makes mounting process easy and fast.
MOUNTING
Step 1 Step 2 Step 3
H
H = 8 7/16”
24 AIR HANDLING UNITS |2017-11 |www.blauberg.us
PERFORMANCE
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 38 81 40 84 42 88 6150 0.2 35 74 36 76 38 81 6175 0.3 32 67 33 69 35 74 61
100 0.4 29 61 30 63 31 65 60125 0.5 26 54 26 56 27 57 61150 0.6 22 46 23 48 22 47 60175 0.7 17 37 18 38 17 36 58200 0.8 12 26 13 27 12 26 59225 0.9 8 16 7 14 8 17 55
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 20 42 25 73 82 0.46
II 0 32 25 53 38 69 79 0.47
III 0 32 30 63 49 68 78 0.45
IV
V -25 -13 20 42
Total Recovery Efficiency
Cooling VI 35 95 20 42 25 54.5 72 0.49
Model Volts Max. Watts Max. Amps
ERV EC D(R) 80 120V, 60Hz 61 0.9
Extract air
Supply airExhaust air
Intake air
ERV EC D 80ERV EC DR 80
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0 10 20 30 40 50 60 70 80 90
SupplyExhaust
25www.blauberg-group.com
DIMENSIONS
ERV EC DR 80
ERV EC D 80
Ø 4 7/8”
Ø 4 7/8”
4 1/16”
4 1/2” 29 13/16”
26”
21 15/16” 8 7/16” 4 7/16”
8 7/16” 4 7/16”
3 7/8 ”
3 7/8 ”
9 1/2 ”
9 1/2 ”
20 3/
16”
20 3/
16”
18 1/16”
9 1/2 ”
17 1/
16”
17 1/
16”
9 1/2 ”
Ø 4 7/8”
Ø 4 7/8”
4 1/16”
4 1/2” 29 13/16”
26”
21 15/16” 8 7/16” 4 7/16”
8 7/16” 4 7/16”
3 7/8 ”
3 7/8 ”
9 1/2 ”
9 1/2 ”
20 3/
16”
20 3/
16”
18 1/16”
9 1/2 ”
17 1/
16”
17 1/
16”
9 1/2 ”
ERV EC D 80ERV EC DR 80
ENERGY RECOVERY VENTILATION
26 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
• 176 CFM airflow rate provides effective ventilation in apartment overcoming high pressure in condo tower duct systems.
• Cross flow core ensures up to 66% SRE.• Slim casing design (9 1/16”) is perfect for in-ceiling installation.• Build in control board enables Supply and Exhaust fan inde-
pendent speed adjustment from 0 to 100% right at the job side.• Fast and simple mounting process thanks to brackets system.• Automatic recirculation damper (R option) for effective cold
protection.• No drain needed (ERV).• Up to 2.86 CFM/W (Energy Star requirement – 1.2 CFM/W).
Steel casing is covered with high-quality multilayer alu-minium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
CASING
DESCRIPTION
FILTERWashable MERV 6 air filters in exhaust and supply air streams.Optional supply: anti grease aluminum filter.
Defrost system is activated when the outdoor temperature falls below 23° F (-5° C).Recirculation defrost HRV/ERV EC DR 120.Fan stop defrost HRV/ERV EC D 120.
DEFROST SYSTEM
High efficient electronically commutated motors with ex-ternal motor and impeller with forward curved blades. EC motors are featured with high performance and total speed controllable range. The electric motors and impellers are dy-namically balanced.
FANS
The unit incorporates an integrated automation and control system with following functions: • Operation mode switch.• Airflow balancing enabled by supply and exhaust fan inde-
pendent speed adjustment from 0 to 100% (percentage is displayed on built in screen).
• Automatic recovery core frost protection.• External control device connection (up to 5 at the same time).
CONTROL
5 year warrantyWARRANTY
HRV EC D(R) 120 ERV EC D(R) 120
Backdraft Dampers ClampsAir disk valve
ACCESSORIES
Timer
Aluminum cross-flow core (HRV EC D(R) 120) ensures efficient heat recovery.
Enthalpic core (ERV EC D(R) 120 provides both heat&humidity recovery. For enthalpic core no drain required.
HEAT RECOVERY CORE
27www.blauberg-group.com
HRV EC D(R) 120 ERV EC D(R) 120
HEAT AND ENERGY RECOVERY VENTILATION
Due to low height of the casing the units offer perfect solution for the false ceiling installation in limited space.Brackets system makes mounting process easy and fast.
MOUNTING
Step 1 Step 2 Step 3
H
H = 9 1/16”
28 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 83 176 86 181 81 171 19850 0.2 80 170 83 175 79 167 19775 0.3 78 166 81 171 78 164 195
100 0.4 76 162 79 167 76 162 192125 0.5 74 157 77 162 75 159 191150 0.6 73 156 76 160 74 156 190175 0.7 71 151 74 156 72 153 188200 0.8 70 148 72 152 71 150 186225 0.9 67 141 70 147 69 146 183250 1 64 137 67 142 67 141 181275 1.1 62 132 64 136 64 136 178300 1.2 59 126 61 130 61 129 175325 1.3 56 119 58 122 58 122 171350 1.4 52 110 53 111 53 113 166
375 1.5 45 95 43 91 46 97 157
400 1.6 34 71 23 49 34 72 141425 1.7 17 35 8 17 17 36 128450 1.8 9 20 0 0 9 20 124
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 31 66 23 66 66 0.42
II 0 32 45 95 50 63 63 0.36
III 0 32 50 106 66 62 62 0.34
IV
V -25 -13
Total Recovery Efficiency
Cooling VI 35 95 31 66 23 50 62 0.34
Model Volts Max. Watts Max. Amps
ERV EC D(R) 120 120V, 60Hz 198 2.5
PERFORMANCE ERV EC D(R) 120
Extract air
Supply airExhaust air
Intake air
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0 20 40 60 80 100 120 140 160 180 2000
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0 20 40 60 80 100 120 140 160 180 200
SupplyExhaust
SupplyExhaust
HRV EC D(R) 120 ERV EC D(R) 120
29www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATION
PERFORMANCE HRV EC D(R) 120
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 89 189 92 195 83 175 20450 0.2 87 185 90 190 81 171 20175 0.3 85 180 88 185 79 167 200
100 0.4 82 175 85 180 78 164 198125 0.5 80 169 82 175 76 161 196150 0.6 78 165 80 170 75 159 194175 0.7 76 160 78 165 74 157 193200 0.8 74 156 76 161 73 154 190225 0.9 68 144 74 156 70 149 188250 1 66 140 71 151 68 144 186275 1.1 64 135 69 145 66 139 183300 1.2 61 128 66 140 63 132 180325 1.3 57 121 63 134 59 125 176350 1.4 52 110 60 127 54 114 176375 1.5 43 91 55 117 44 94 164400 1.6 30 64 44 92 31 67 151425 1.7 17 35 18 37 17 36 132450 1.8 8 16 7 14 8 16 128
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 31 66 23 62 69 0.05
II 0 32 45 95 50 60 67 0.04
III 0 32 50 106 66 58 65 0.04
IV
V -25 -13
Total Recovery Efficiency
Cooling VI 35 95 31 66 23 37 61 0.04
Model Volts Max. Watts Max. Amps
HRV EC D(R) 120 120V, 60Hz 198 2.5
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0 20 40 60 80 100 120 140 160 180 2000
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0 20 40 60 80 100 120 140 160 180 200
SupplyExhaust
SupplyExhaust
HRV EC D(R) 120 ERV EC D(R) 120
30 AIR HANDLING UNITS |2017-11 |www.blauberg.us
HRV EC D(R) 120 ERV EC D(R) 120
DIMENSIONS
HRV EC DR 120 | ERV EC DR 120
HRV EC D 120 | ERV EC D 120
3 3/4” 12 3/
8 ”
5 13/16”
5 13/16” 34 7/8” 30 15/16”
12 3/
8 ”
20 1/
16”
3/4”
20 1/
16”
26 3/8” 22 7/16”
Ø 4 7/8” 1 1/8”
1 7/16” 12 5/
8 ” 23
1/4 ”
9 1/16” 3 9/
16”
3 9/16
” 3 15/16”
9 1/16” 3 15/16”
12 5/
18”
23 1/
4 ”
Ø 4 7/8”
3 3/4” 12 3/
8 ”
5 13/16”
5 13/16” 34 7/8” 30 15/16”
12 3/
8 ”
20 1/
16”
3/4”
20 1/
16”
26 3/8” 22 7/16”
Ø 4 7/8” 1 1/8”
1 7/16” 12 5/
8 ” 23
1/4 ”
9 1/16”
3 9/16
” 3 9/
16”
3 15/16”
9 1/16” 3 15/16”
12 5/
18”
23 1/
4 ”
Ø 4 7/8”
31www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATION HRV EC D(R) 120 ERV EC D(R) 120
32 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
• 181 CFM airflow rate provides effective ventilation in apartment overcoming high pressure in condo tower duct systems.
• Cross flow core ensures up to 73% SRE.• Slim casing design (9 1/8”) is perfect for in-ceiling installation.• Build in control board enables Supply and Exhaust fan inde-
pendent speed adjustment from 0 to 100% right at the job side.• Fast and simple mounting process thanks to brackets system.• Automatic recirculation damper (R option) for effective cold
protection.• No drain needed (ERV).• Up to 2.56 CFM/W (Energy Star requirement – 1.2 CFM/W).
Steel casing is covered with high-quality multilayer alu-minium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
CASING
DESCRIPTION
FILTERWashable MERV 6 air filters in exhaust and supply air streams.Optional supply: anti grease aluminum filter.
Defrost system is activated when the outdoor temperature falls below 23° F (-5° C).Recirculation defrost HRV/ERV EC DR 150.Fan stop defrost HRV/ERV EC D 150.
DEFROST SYSTEM
High efficient electronically commutated motors with ex-ternal motor and impeller with backward curved blades. EC motors are featured with high performance and total speed controllable range. The electric motors and impellers are dy-namically balanced.
FANS
The unit incorporates an integrated automation and control system with following functions:• Operation mode switch.• Airflow balancing enabled by supply and exhaust fan inde-
pendent speed adjustment from 0 to 100% (percentage is displayed on built in screen).
• Automatic recovery core frost protection.• External control device connection (up to 5 at the same time).
CONTROL
5 year warrantyWARRANTY
HRV EC D(R) 150 ERV EC D(R) 150
Backdraft Dampers ClampsAir disk valve
ACCESSORIES
Timer
Aluminum cross-flow core (HRV EC D(R) 150) ensures efficient heat recovery.
Enthalpic core (ERV EC D(R) 150) provides both heat&humidity recovery. For enthalpic core no drain required.
HEAT RECOVERY CORE
33www.blauberg-group.com
HRV EC D(R) 150 ERV EC D(R) 150
HEAT AND ENERGY RECOVERY VENTILATION
Due to low height of the casing the units offer perfect solution for the false ceiling installation in limited space.Brackets system makes mounting process easy and fast.
MOUNTING
Step 1 Step 2 Step 3
H
H = 9 1/8”
34 AIR HANDLING UNITS |2017-11 |www.blauberg.us AIR HANDLING UNITS |2017-11 |
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 85 181 88 186 81 171 18650 0.2 82 175 85 180 78 165 18675 0.3 80 169 82 174 75 159 186
100 0.4 77 162 79 167 72 153 185125 0.5 74 156 76 161 70 147 185150 0.6 70 149 73 154 67 141 184175 0.7 67 142 69 146 64 135 184200 0.8 64 135 66 139 61 128 184225 0.9 55 117 62 131 57 121 183250 1 52 110 58 123 54 114 182275 1.1 49 104 54 115 51 107 181300 1.2 45 96 50 107 47 99 181325 1.3 42 88 46 97 43 91 180350 1.4 38 80 41 88 39 83 178375 1.5 34 73 37 78 36 75 176400 1.6 30 64 32 69 31 66 174425 1.7 26 54 28 58 27 56 172450 1.8 21 45 22 47 22 47 169475 1.9 16 35 17 36 17 36 166500 2 12 24 12 25 12 25 163525 2.1 6 14 7 14 7 14 159550 2.2 2 4 2 3 2 4 156
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 31 66 26 73 82 0.46
II 0 32 46 97 42 70 78 0.38
III 0 32 50 107 52 68 75 0.36
IV
V -25 -13 31 65 89 63 77 0.37
Total Recovery Efficiency
Cooling VI 35 95 31 66 26 50.1 68 0.42
Model Volts Max. Watts Max. Amps
ERV EC D(R) 150 120V, 60Hz 186 2.5
PERFORMANCE ERV EC D(R) 150
Extract air
Supply airExhaust air
Intake air
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
0 20 40 60 80 100 120 140 160 180 2000
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
0 20 40 60 80 100 120 140 160 180 200
SupplyExhaust
SupplyExhaust
HRV EC D(R) 150 ERV EC D(R) 150
35www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATION
PERFORMANCE HRV EC D(R) 150
External Static Pressure Net Supply Air FlowGross Air Flow
PowerSupply Exhaust
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts25 0.1 85 181 88 186 81 171 18650 0.2 82 175 85 180 78 165 18675 0.3 80 169 82 174 75 159 186
100 0.4 77 162 79 167 72 153 185125 0.5 74 156 76 161 70 147 185150 0.6 70 149 73 154 67 141 184175 0.7 67 142 69 146 64 135 184200 0.8 64 135 66 139 61 128 184225 0.9 55 117 62 131 57 121 183250 1 52 110 58 123 54 114 182275 1.1 49 104 54 115 51 107 181300 1.2 45 96 50 107 47 99 181325 1.3 42 88 46 97 43 91 180350 1.4 38 80 41 88 39 83 178375 1.5 34 73 37 78 36 75 176400 1.6 30 64 32 69 31 66 174425 1.7 26 54 28 58 27 56 172450 1.8 21 45 22 47 22 47 169475 1.9 16 35 17 36 17 36 166500 2 12 24 12 25 12 25 163525 2.1 6 14 7 14 7 14 159550 2.2 2 4 2 3 2 4 156
Supply Temperature Net Airflow Average Power (Watts)
SensibleRecovery Efficiency
Apparent Sensible
Effectiveness
NetMoisture Transfer°C °F L/s CFM
Heating
I 0 32 31 66 26 69 78 0.04
II 0 32 46 97 42 67 74 0.05
III 0 32 50 107 52 65 73 0.05
IV
V -25 -13
Total Recovery Efficiency
Cooling VI 35 95 31 66 25.8 40.2 64 0.04
Model Volts Max. Watts Max. Amps
HRV EC D(R) 150 120V, 60Hz 186 2.5
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Ext.
Dif
fere
ntia
l Pre
ssur
e -
in. W
G
Gross Airflow - CFM Gross Airflow - CFM
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
0 20 40 60 80 100 120 140 160 180 2000
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
0 20 40 60 80 100 120 140 160 180 200
SupplyExhaust
SupplyExhaust
HRV EC D(R) 150 ERV EC D(R) 150
36 AIR HANDLING UNITS |2017-11 |www.blauberg.us
DIMENSIONS
HRV EC DR 150 | ERV EC DR 150
HRV EC D 150 | ERV EC D 150
11 13
/16 ”
21 9/
16”
4 5/8”
4 5/8” 9 1/8”
9 1/8”
11 13
/16 ”
2 9/16
”
27 3/4” 31 11/16”
36 1/8” 40 ”
11 13
/16 ”
11 13
/16 ”
25 3/
16”
25 3/
16”
4 5/8”
4 5/8”
Ø 4 7/8”
Ø 4 7/8”
11 13
/16 ”
21 9/
16”
4 5/8”
4 5/8” 9 1/8”
9 1/8”
11 13
/16 ”
2 9/16
”
27 3/4” 31 11/16”
36 1/8” 40 ”
11 13
/16 ”
11 13
/16 ”
25 3/
16”
25 3/
16”
4 5/8”
4 5/8”
Ø 4 7/8”
Ø 4 7/8”
HRV EC D(R) 150 ERV EC D(R) 150
37www.blauberg-group.com
HEAT AND ENERGY RECOVERY VENTILATIONHRV EC D(R) 150 ERV EC D(R) 150
38 AIR HANDLING UNITS |2017-11 |www.blauberg.us
S50 20/40/60 PUSH BUTTON TIMER
An electronic wall control timer that is compatible with all HRV D / ERV D models. This control activates the system on three possible modes of operation.The button activates the system to run in intermittent mode for 20/40/60 minutes, it then returns to the predetermined setting. The light indicator of this wall control shows clearly, in which operating mode the unit is.
• Push once for 20-minute, twice for 40-minute, or three times for 60-minute activation. Indicator lights up and the controlled unit goes to high speed.
• Push once more to stop activation. Unit returns to its pre-vious setting.
CONTROL
DESCRIPTION
ELECTRICAL DIAGRAM
Power supply: 24V AC ±10% or 24V DC ±10%Communication protocol: Normally opened contactUser interface: Push buttonType of indication:• LED 1 = 20 min timer is active;• LED 2 = 40 min timer is active;• LED 3 = 60 min timer is active.Output voltage: 24V AC ±10% or 24V DC ±10%Current Out: 100 mA, max
SPECIFICATION
Button
20 min
24 VACCOMHigh
NO
40 min
60 min
39www.blauberg-group.com
11/2017
Technical changes reserved.Illustrations and texts are non-binding.