CORPORATE PROFILECORPORATE PROFILE
2
�Established in 1993
�Specialized in the design & manufacturing of wireless
telemetry equipment
�Professionals with huge experience on:
� Telecommunications, security, energy.
� Irrigation, water management.
3
TARGET
�Lead the wireless telemetry market
�Be the reference provider for the radio systems
integrators
4
ATTITUDE
�Intensive investment in R+D
�Partners & customers close collaboration
�Anticipate needs in a global market
5
“Manufacture what our customers
and integrators would design
with the best engineering and
technical assistance service ”
Key to our success:
6
EXCELLENCE
�Radiofrequency
�REAL TIME data acquisition
�ULTRA LOW power technology
7
PRODUCT RANGE
T-MOD
UMF TAFAMF
UMB
8
Electrical distributionnetworksRemote control for powergeneration plants, stations, substations andsupply qualitysurveillance.
APPLICATIONS
LotteriesWireless networks forbetting transfers.
Water supplyRemote control of sewageplants, fresh water plants, reservoirs and distributionnetworks.
Power Supply, Security and
Services Aplications
Gas and oil
Remote control ofdistribution networksand process plants.
Water Management
Street Lighting
Centralized control ofstreet lighting.
Environment
Environmental data telemetry.
Motorways andrailwaysRemote control oftraffic measurementand signaling.
IrrigationWireless control systems foragricultural, golf courses andparks irrigation.
9
T-MOD
Short & Long Distance Radiomodems
10
T-MOD RADIOMODEM
� VHF & UHF 403–512 MHz: max.
reach 30 to 40 km
� 4800 / 9600 bps
� Store & Forward MODBUS RTU
repeater mode
� Back to Back repeater mode
(frequency change)
� TX radio power: 0.1W-5W;25W
� 2 options: External AMF module
for old models / Embedded AMF
for new models with IEEE
802.15.4 Standard (ZigBee
mesh networking)
� Power supply: 12 Vcc
� Half-duplex
� Low latency
� Data protocol transparent
� Redundant configurations
� Injected aluminium box
� RS-232, RS-485 & Ethernet
10/100 data ports
� Non-intrusive diagnostic
11
RTU
RTU
RTU
40 Km
40 Km
40 Km
RS-232 / RS-485
RS-232 / RS-485RS-232 / RS-485
T-MOD RADIOMODEM
12
UMF-100
Universal Module
13
UMF-100 MODULE
� Universal Module
� ModBus Protocol
� Digital / Analog input and output signals
� RS-232 / RS-485 intelligent converter
� Master / Slave / Front End
� Isolator / Replicator / Multiplier / Filter
14
UMF-100 MODULE
MASTER
RS-232 RS-232
RS-485RS-485
40 Km
15
AMF
Protocol Converter
16
� SERIAL – SERIAL
� ETHERNET – SERIAL
� ETHERNET – ETHERNET
� RS-232, RS-422, RS-485, MPI, ProfiBus,
GSM, USB, XBee, 802.3u (10/100 Mb)
AMF PROTOCOL CONVERTER
17
RS-232 RS-23240 Km
AMF PROTOCOL CONVERTER
ETHERNET PLC
PLC
ETHERNET
ETHERNET
RS-232
RS-485
18
REMOTE UNIT (IRU) MASTER UNIT (IMU)
The Smart Irrigation Control System
19
� Real-time irrigation control: valves and counters
� Autonomous power in remote units (≥ 3 years)
� 4 analog inputs: pressure, moisture…
� 12 counters
� 1.280 hydrants x Master Unit (IMU) (128 IRU x
IMU)
� Over 5.000 Ha x Master Unit (IMU)
20
21
TAF
One Way Remote Control System
22
� Long range digital command (up to 30 km)
� VHF & UHF
� Point-to-point system with 2, 5 or 8 channels / Custom
multi-receiver with 16, 24 or 32 channels
� Optional repeater mode
� 12V Battery power-operated transmitter (>2 years)
� Double/simple water rate control for pumping
� Robustness (IP-65 box)
TAF DIGITAL
23
230 VAC
TAF DIGITAL
MAX LEVEL
MIN LEVEL
RECEIVERTRANSMITTER
PUMP
TRANSMITTERRECEIVER
TRANSMITTER
24
UMB
System for Drinking Water Management
25
� Specific remote control system for drinking water supply networks
� Pumping, reservoir and network points control
� Long range (up to 30 km)
� Frontal Control Panel
� Analog measures (0-5 V or 4-20 mA)
� Counter inputs
� Auxiliary digital inputs
� Optional repeater mode
� Centralized supervision software with remote access
UMB SYSTEM
26
RESERVOIR
RESERVOIR
EXPANSION RESERVOIR
NETWORKPOINT
PUMPING
STATIONPUMPING STATION
CONTROL CENTER
SYNOPTIC
RADIOMODEM
SCADA SOFTWAREPHONEMODEM
RESERVOIR
REPEATER
CEN
SX
BS/BA
DS/DA /DT/DT2
DS/DA /DT/DT2
BDr/BDr2
DS/DA /DT/DT2
BD/BDr/BD2
PUMPING STATION
UMB SYSTEM
27
REFERENCES
28
REFERENCES
Biggest hydraulic project in Spain with a total irrigation surface of 70.150 ha for 16.000 people in charge of irrigation and a total budget of 1.069 million € for irrigation network and plot concentration.3.000 IRRIMATION units from Farell Instruments were installed for the remote control of the whole system.
Algerian electrical network monitoring through more than 1250 T-MOD radiomodems, based on SNMP technology.The basic functions are:- Display status and alarms of all T-MOD units.- Real time alarm automatic notification on customer’s network monitor systemthrough SNMP traps.
29
REFERENCES
First integral management services group specialized in water in Spain. One of themost important worldwide. More than 1000 radio points implemented in the mostimportant groups of water management.
Street lighting control, electric cabinet manufacturing and industrial automation. Introduction of the radio equipments for street lighting control of cities likeBarcelona, Palma de Mallorca, Girona and La Coruña (more than 1750 pointsinstalled).
Tunisian electrical network monitoring through more than 2200 T-MOD radiomodems with active redundancy.
30
REFERENCES
Company in charge of the Generalitat de Catalunya public lottery (Catalangovernment). Radio equipments update to receive bets in real time (more than 2.300 points).
First electric group in Spain and one of the biggest in the world with more than40,00 MW installed, 137 GWh distributed and more then 24,6 million customers in 10 countries.Farell Instruments installed for ERZ, ENDESA regional affiliate, a radio network tocontrol transformation and distribution stations formed by a combination oftransparent radiomodems (T-MOD) and addressable radiomodems with more than150 points installed.
31
� 20.000 T-MOD installed in many different applications and sectors
� 2.000 UMB & 1.500 TAF delivered to system integrators from the
water supply market
� 5.000 UMF: diverse customers, mostly delivered to electrical
distributors and small integrators
� 1.000 AMF for small system integrators
� 6.000 IRRIMATION systems installed
REFERENCES
32
www.farell-i.com