Heat distribution measurement film
THERMOSCALE 200C
Mr. Bernard GenoudSales CCTV & Industrial Products
FUJIFILM (Switzerland) AG
2
To measure heat distribution easily by observingthe variation in density and hue.
Contact for5 seconds
Cyan → Change density → Plus Magenta →& Change hue
150 160 170 180 190 200 210 ℃
Contact for20 seconds
What is Thermoscale200C?
℃Properties℃
*Above chart is a sample based on the results of a tests performed at Fujifilm.Before using THERMOSCALE, create a similar chart that is based on the actual measurement conditions.
3
℃Structure℃ ℃Specifications℃
0.09mmThickness
5 sheetsSheets
270mm x 200mmSize
150� - 210�(Contact time = 5-20 sec)
Temperature range*
*Actual temperature range depends on conditions of use includingcontact time, Materials, pressure, and air flow.
0.09mmThickness
270mm x 5mSize
150� - 210�(Contact time = 5-20 sec)
Temperature range*
℃Sheet type℃
℃Roll type℃(Coming soon)
4Heat
℃Color-forming materialdissolves
℃Wall of microcapsule becomes permeable.Color-developing material penetrates the capsule
℃Reacting color-forming material,causing an area of color to appear
℃Principle℃
Color-developingmaterial
Microcapsule
Color-formingmaterial
5
Heat Point
Heat Distribution
Contact
heat
Open
heat
℃Positioning℃
Thermocouple
Thermo label
ThermoscaleThermograph
y
6
Problems about ordinary measurement of heat distribution
℃℃To measure heat distribution
℃℃To measure heat value
℃℃Low resolution
7
Problem 1-1To measure heat distribution
Thermocouples
- Several thermocouplesand Power source required
- Need times to preparespecial jig to set upthermocouples
- Contact condition ischanged by thickness ofattached thermocouples
Powersource
8
If use Thermoscale-Easy operationNo power source requiredCut and fit any dimensions
-Time savingNo special jig required
-Similar to contact conditionFlat and thin film
Thermoscale
9
Thermography -Just measure the surfaceof target but not measure thereal heat distribution
℃℃℃℃
Problem 1-2To measure heat distribution
10℃℃℃℃
-RealityMeasure the real heatdistribution of target
Thermoscale
If use Thermoscale
11℃℃℃℃
Point A℃Center℃Point B
℃Corner℃
Time
Temperature
AB
Same ultimate temperatureBut different heat value
Problem 2To measure heat value
12℃℃℃℃
Thermoscale Point A℃Center℃Point B
℃Corner℃
If use Thermoscale
Time
Temperature
AB
-Process controlVisualize heat value
Heat value (A-B)
13℃℃℃℃
Temperature
Heat
Problem 3Low resolution
10µm
Electronic wiring
Heat will be changed according tothe condition of contacted “Work”
Work
-Not measure 10µ℃ widthby thermocouples
-Not measure several tens ofpoints all at once
14℃℃℃℃
℃℃
Thermoscale
-High resolutionVisualize several 10µm
If use Thermoscale
-High performanceMeasure several tens ofpoints all at once
10µm
- Design electronic wiring pattern- Control heat unevenness
Work
15
Application Examples
16
Expected application
Validation of sterilizationCheck the heat sealer for packaging of sealable pouches
NG OK
Thermoscale200C
17
Conclusion
Thermoscale has the following advantages:
• Can be used in a wide range of applications• Gives accurate results• Covers a wide temperature range with different film types• Is simple to handle
The use of Thermoscale Film can accelerate the developmentof products in R&D and increases the productivity.
18
Thank you very much for your attention!
Distributor for Switzerland:FUJIFILM (Switzerland) AGNiederhaslistrasse 128157 DielsdorfTel.: +41 (0) 44 855 50 [email protected]/industrial