GE Power Management 269Plus Motor Management Relay
Offering optimum motor protection in situations where other relays cannot, the 269 Plus Motor Management Relay possesses the unique feature of its ability to “learn” individual motor parameters, giving it the flexibility to adapt to each application by “learning” values of motor inrush current, negative sequence current K factor, cool down rates, start thermal capacity and acceleration time.
GE Power Management 269Plus Motor Management Relay
Presentation OverviewPresentation Overview
66 ApplicationsApplications
66 Protection and Protection and ControlControl
66 Metering andMetering andMonitoringMonitoring
66 Inputs and Inputs and OutputsOutputs
66 User InterfaceUser Interface
66 OrderingOrdering66 CommunicationsCommunications
66 Typical WiringTypical Wiring
ApplicationsApplications
GE Power Management 269Plus Motor Management Relay
The 269 Plus is a microprocessor basedproduct designed to provide complete andaccurate protection for industrial motorsand their associated mechanical systems.
=Three phase AC motors
=Mechanical system protection
MAINMAIN
GE Power Management Applications
3 /
269Plus RELAY
52 50 50G
400A
4160V BUS(4)
ISOLATEDANALOGOUTPUTS
COMMUNICATIONwith
METERING OPTION
VOLTSMETERING OPTION
AMPS MPM
48 46 66
50 51 49 37 86
47 55 27
7437
49
38
50G 51G
14
87 52b
RTD
MOTOR
14
87
LOAD
AMBIENT AIRSTATOR RTDs
BEARING RTDs
SPEED DEVICECONTACTS
DIFFERENTIALRELAY CONTACTS
SPARE INPUTSTARTER AUXILIARY B CONTACT
RS485REMOTE
COMMUNICATION
SELF TESTALARM
AUXILIARYRELAY #1
AUXILIARYRELAY #2
TRIPRELAY
ALARMRELAY
GROUND CT
PHASE CTs
FUSEDCONTACTOR
269PLUS RELAY269PLUS RELAY
FUNCTIONALBLOCK
DIAGRAM
MAINMAIN
Legend
GE Power Management Applications
14 Speed Device37 Undercurrent/Minimum Load38 Motor/Load Bearing Overtemperature46 Unbalance - Negative Sequence48 Multiple Starts/Locked Rotor49 Stator Winding Overtemperature49/51 Overload Curves/FlexCurves50 Short Circuit/Mechanical Jam/Rapid Trip50G/51G Zero Sequence Ground Fault50N/51N Residual Ground Fault52b Breaker74 One Alarm Relay, Two Auxiliary Relays86 Main Trip Latched Relay
Auxiliary Relay No. 1Auxiliary Relay No. 2
87 Differential Relay Contact Input66 Starts per hour47 Volts Phase Reversal (Meter Option)27 Undervoltage (Meter Option)
Frequency (Meter Option)55 Power Factor (Meter Option)
DEVICE PROTECTION
GE Power Management 269Plus Motor Management Relay
ProtectionProtection
=Stator windingovertemperature
=Bearingovertemperature
=Multiple starts
=Overloads
=8 standard overload curves
=Ground fault
=Undercurrent
=Phase reversal (meter option)
=Variable lock out time
=“Learns” individual motor parameters
=Short circuit
=User defined overloadFlexCurveTM
=Locked rotor
=Rapid trip/mechanical jam
=Unbalance/single phasing
MAINMAIN
GE Power Management
Start and RunningStart and Running
269Plus Motor Management Relay
=Motor is protected under both Acceleration and Runningconditions
The 269 Plus can trigger an alarm or trip the motor based on:
=normal acceleration time=number of starts per hour=multiple starts=time between starts=motor overload conditions
MAINMAIN
GE Power Management
=One of eight standard overload curves may be programmed based on motor manufacturer’s locked rotor time capability.
=Alternately, the user may program in a custom curve using the built-inFlexCurve™ function.
Protection
OverloadOverload
MAINMAIN
View 8 Standard Overload Curves
GE Power Management Protection
8 Standard Overload Curves
Full Load Current Setpoint Multiples of Full Load Current Setpoint
=The motor’s service factor value is entered as the overload pickup level
GE Power Management
FlexCurve can be used to protectmotors which have different rotorand stator damage, allowing totalmotor design capacity with complete protection.
When a FlexCurve is programmed,the 269 Plus develops a smoothcustom overload curve within a selected range.
Protection
FlexCurveFlexCurve™™
1
2
3
4
5
Multiples of Full Load Current Setpoint
6500 HP, 13800 Volt INDUCED DRAFT FAN MOTOR
1) Programmed 269 Plus Custom Curve
2) Running Safetime (Rotor Limited)
3) Acceleration Safetime(Rotor Limited)
4) Motor Current @ 100% Voltage
5) Motor Current @ 80% Voltage
GE Power Management Protection
Thermal ModelingThermal Modeling
The Thermal Model within the 269Plus has the ability to computethe motor I2t value based on actual motor load current.
=thermal model calculates value in terms of thermal capacity used
=RTDs (resistance temperature units) measuring stator temperature act as a thermal capacity check to confirm value calculated bythermal model. RTDs may be used for monitoring stator, bearing,ambient, or other temperature monitoring.
=thermal capacity used is then updated to reflect the higher of the two values
MAINMAIN
GE Power Management Protection
MotorMatch modifies the initially entered relay parameters to match actual measured motor characteristics. The key elements include:
=accumulated I2t in the memory=RTD input to the memory=learned cooldown time from run to stop=learned cooldown time from run-overload to run-normal
=learned acceleration time=learned negative sequence contribution (K-factor)
Motor MatchMotor Match
MAINMAIN
GE Power Management Protection
RTD Hot Motor CompensationRTD Hot Motor Compensation
When hot motor compensation is enabled:=RTD feedback from actual stator temperature checks
the thermal capacity model
=User has the capability to match the motor thermalcharacteristics with a dual slope RTD bias curve
=The two part curve allows for easy fitting of hot and cold motor damage curves to the RTD bias feature
MAINMAIN
GE Power Management 269Plus Motor Management Relay
User InterfacesUser Interfaces
=PC Software for setting, monitoring=48 character alpha-numeric backlit
LCD display=Five Target LED indicators=MPM (meter) com port=RS485 com port (ModBus® RTU)
MAINMAIN
GE Power Management User Interfaces
HELP KEY=Help key can be pressed at
any time to provide additionalinformation
PROTECTIVE COVER=Rugged, corrosion and flameretardant case
=Meets IP53/NEMA 12
MAINMAIN
GE Power Management User Interfaces
DISPLAY=48 Character alpha-numeric backlitLCD display for viewing actual values, causes of alarms and trips, and programming setpoints.
STATUS INDCATORS=5 LEDs indicate when an output isactivated. When an LED is lit the cause of the output relay operationwill be shown on the display.
KEYPAD=Used to select the display of actual values, causes of alarms, causes of trips, fault diagnosis and toprogram setpoints.
I 1=120 I 2=120I 3=121 (AMPS)
MAINMAIN
LINE
2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3
T R IPN C R E L A Y N O
RS422
MULTILIN
269 B200REV. C608/96
TM201
TM201
TM202
TM202
TM203
TM203
TM217
TM216
TM204
TM212
TM205
TM213
TM206
TM214
TM207
TM215
RX-RX+
A L A R MN C R E L A Y N O
A U X 1N C R E L A Y N O
A U X 2N C R E L A Y N O
C O N T R O L P O W E RL ( + ) G L 2 / N ( - )
SPARE- +
METER
- +DIFF.- +
SP. SW.
- +AC
CESS
- +EM
.RST- +
EX. RES- +
- +RS485- +
R228
G N DJ 2 0 1H P O T
8 3 8 2 8 1 8 0 7 9 7 8 7 7 7 6 7 5 7 4 7 3 7 2
G R O U N D F A U LT2 0 0 0 C O M : 5
P H A S E 3: 1 C O M 5
P H A S E 2: 1 C O M 5
P H A S E 1: 1 C O M 5
T201
T202
T203
T204
44
47
51
56
47
639
684
45
48
52
57
88
S H D
648
693
46
50
55
46
621
0
675
49
54
59
611
1
666
711
53
58
601
2
657
702
GE Power Management User Interfaces
CONTROL POWER=120/125 AC/DC=240/250 AC/DC=24 AC/DC, 48 AC/DC
4 OUTPUT RELAYS=Programmable alarm and trip conditions activated by:=programmable setpoints=switch input=remote communication control
RTD 7-10=Can be assigned to monitor motor and load bearings, and ambient temperature
INPUTS/OUTPUTS=Spare input=MPM (meter) com port=Differential relay input=Speed switch input=Access input=Emergency restart=External output=Analog output=RS485 com port
RTD 1-3=Typically used for statorwinding protection
RTD 4-6=Typically used for statorwinding protection
Phase and ground CT inputs Contrast dial MAINMAIN
GE Power Management 269Plus Motor Management Relay
CommunicationsCommunications
=Successfull interface with many PLCssuch as Modicon, Square D, Allen Bradleyand GE Fanuc
ProtocolProtocol>> Modbus® RTU protocol
Terminals for RS485 located on rear port of the relay
MAINMAIN
GE Power Management 269Plus Motor Management Relay
MeteringMetering
=average and individual phase currents=RTD temperatures (hottest, individual, maximum)=unbalance ratio (%In/Ip)=ground leakage current=thermal capacity remaining / estimated time to tripat present overload level
=motor load as a percent of full load=phase to phase or phase to neutral voltage(meter option)
=W, var, MWhr, PF, Hz (meter option)
Actual ValuesActual Values
MAINMAIN
GE Power Management 269Plus Motor Management Relay
MonitoringMonitoring
=immediate overload/stall warning=ground fault=mechanical jam=unbalance=undercurrent=RTD overtemperature, broken RTD sensor, low temperature RTD
=self-test-service=under/overvoltage (meter option)=low power factor (meter option)
Prior AlarmsPrior Alarms
MAINMAIN
GE Power Management 269Plus Motor Management Relay
MonitoringMonitoring
Fault DiagnosisFault Diagnosis
=269 Plus displays the cause of the trip andwill show the remaining lock-out time if applicable
=cause of the last trip and pre-trip values can be recalled for rapid fault diagnosis.
MAINMAIN
GE Power Management 269Plus Motor Management Relay
Statistical Data (Statistical Data (StatTracStatTracTMTM))
=StatTracTM provides statistical data of motor use foroperations monitoring, maintenance, and fault diagnosis.
=Using the Keypad, the user can display:
MonitoringMonitoring
=running hours and number of starts since last commissioning =number of all trips=number of specific types of trips=total Watt-hours (with meter option)
MAINMAIN
GE Power Management 269Plus Motor Management Relay
InputsInputs
==Speed Switch InputSpeed Switch Input
==Differential Relay InputDifferential Relay Input
==Spare InputSpare Input
=enables the user to use an external speed device
=provided terminals to accept contact closure from an externaldifferential relay
=all protective functions grouped through one main relay
=spare input terminals configurable to represent either a standard contact input(ie-pressure switch), or a specific contact input (circuit breaker/contactor status)
=52b contact from a circuit breaker = positive identification of the position of the breaker(open or closed)
MAINMAIN
GE Power Management 269Plus Motor Management Relay
OutputsOutputs
==4 Output Relay Contacts4 Output Relay Contacts=Trip Relay as main latched output relay =Alarm output relay (latched or unlatched)=Auxiliary 1 output relay (latched or unlatched)=Auxiliary 2 output relay
==Analog outputAnalog output=Used to indicate motor thermal capacity used,motor current, hottest stator RTD, bearing RTD, or CTsecondary current
MAINMAIN
MOTOR
MOTOR
ZERO SEQUENCE GROUND CONNECTION
269Plus TYPICAL WIRING
RESIDUAL GROUND CONNECTION
(ALTERNATE)
ALTERNATE CONNECTIONFOR
COMMON SHIELD
START STOP FUSE
GROUNDBUS
52b
METER COM PORT
EXTERNAL CONTACTSEXTERNAL CONTACTS
JUMPER OR KEYSWITCH
KEYSWITCH
EXTERNAL RESETAMMETER OR PROGRAMMABLE CONTROLLER
RS485 COM PORT
GROUNDED AT MASTER ONLY
PHASE A CT
MAINMAIN
PHASE B CT
PHASE C CT 50:0.025 GROUND CT
PHASE A CT
PHASE B CT
PHASE C CT
269PLUS * * * * * *269PLUS Motor Management RelaySV Standard version
D/O Drawout versionPhase CT 1 Ground CT (required for D/O only)
1 :5 2000:12 :5 :53 :1 2000:14 :1 :5
Relay fail safe code2 (required for D/O only)Trip Alarm Aux1 Aux2
1 FS NFS NFS FS2 NFS FS NFS FS3 FS FS NFS FS4 NFS NFS FS FS5 FS NFS FS FS6 NFS FS FS FS7 FS FS FS FS8 NFS NFS NFS FS
Relay contact arrangement3 (required for D/O only)Alarm Aux1 Aux2
1 N.O. N.O. N.O.2 N.O. N.O. N.C.3 N.O. N.C. N.O.4 N.O. N.C. N.C.5 N.C. N.O. N.O.6 N.C. N.O. N.C.7 N.C. N.C. N.O.8 N.C. N.C. N.C.
100P 100 Ohm platinum RTD10C 10 Ohm copper RTD
100N 100 Ohm nickel RTD120N 120 Ohm nickel RTD
120 120 AC/125 DC control voltage240 240 AC/250 DC control voltage24DC 24 DC control voltage48DC 48 DC control voltage
OORRDDEERR
CCOODDEE
GE Power Management
269Plus Motor Management Relay269Plus Motor Management Relay