+ All Categories
Transcript
Page 1: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

11.8.1

TABLE OF CONTENTS

CF0040PE – Building Elevation ..................................................................................................3HR3 INSULATED ROOF PANEL...................................................................................4FASTENER REQUIREMENTS.......................................................................................4

EA4000 – Roof Panel Side Lap...................................................................................................4EA4021 – Panel end lap..............................................................................................................5

LOW EAVE DETAILS.....................................................................................................6ED4310 – Horizontal Gutter with Sculptured Rake .....................................................................6

HIGH EAVE DETAILS ....................................................................................................7EH4006 – High Eave with Wall Panel .........................................................................................7EI4010 – High Eave (Parapet) ....................................................................................................8EI4030 – High Eave (Parapet) at Masonry or Concrete..............................................................9EI4050 – High Eave (Parapet) Panel Above and Below ...........................................................10EI4070 – High Eave (Parapet) Non-Structural ..........................................................................11

RAKE DETAILS............................................................................................................12EE4010 – Rake (Sculptured).....................................................................................................12EF4010 – Rake (Parapet) Wall Panel Above ............................................................................13EF4030 – Rake (Parapet) at Masonry or Concrete...................................................................14EF4050 – Rake (Parapet) Rafter in High Building.....................................................................15EF4060 – Rake (Parapet) Rafter in Low Building .....................................................................16

PARAPET GUTTER DETAILS.....................................................................................17EK4020 – Parapet Gutter – Eave Strut .....................................................................................17EK4040 – Parapet Gutter @ Masonry Or Concrete – Eave Strut .............................................18

RIDGE DETAILS ..........................................................................................................19EG4010 – Ridge Condition........................................................................................................19

SR2 INSULATED ROOF PANEL .................................................................................20FASTENER REQUIREMENTS.....................................................................................20

EA5000 – Roof Panel Side Lap.................................................................................................20EA5021 – Roof End Lap............................................................................................................21

LOW EAVE DETAILS...................................................................................................22ED5310 – Horizontal Gutter with Sculptured Rake ...................................................................22

HIGH EAVE DETAILS ..................................................................................................23EH5006 – High Eave with Wall Panel .......................................................................................23EI5010 – High Eave (Parapet) ..................................................................................................24EI5030 – High Eave (Parapet) at Masonry or Concrete............................................................25EI5050 – High Eave (Parapet) Panel Above and Below ...........................................................26EI5070 – High Eave (Parapet) Non-Structural ..........................................................................27

RAKE DETAILS............................................................................................................28EE5010 – Rake (Sculptured).....................................................................................................28EF5010 – Rake (Parapet) Wall Panel Above ............................................................................29EF5030 – Rake (Parapet) at Masonry or Concrete...................................................................30

Page 2: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

11.8.2

EF5050 – Rake (Parapet) Rafter in High Building.....................................................................31EF5060 – Rake (Parapet) Rafter in Low Building .....................................................................32

PARAPET GUTTER DETAILS.....................................................................................33EK5020 – Parapet Gutter – Eave Strut .....................................................................................33EK5040 – Parapet Gutter @ Masonry or Concrete – Eave Strut ..............................................34

RIDGE DETAILS ..........................................................................................................35EG5010 – Ridge Condition........................................................................................................35

Page 3: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLE11.8.3

CF0040PE – BUILDING ELEVATION

Page 4: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEA4000.DWG 11.8.4

HR3 INSULATED ROOF PANELFASTENER REQUIREMENTSEA4000 – ROOF PANEL SIDE LAP

Page 5: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 12/22/17BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEA4021.DWG 11.8.5

EA4021 – PANEL END LAP

Page 6: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEED4310.DWG 11.8.6

LOW EAVE DETAILSED4310 – HORIZONTAL GUTTER WITH SCULPTURED RAKE

Page 7: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEH4006.DWG 11.8.7

HIGH EAVE DETAILSEH4006 – HIGH EAVE WITH WALL PANEL

Page 8: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 08/02/16BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEI4010.DWG 11.8.8

EI4010 – HIGH EAVE (PARAPET)

Page 9: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEI4030.DWG 11.8.9

EI4030 – HIGH EAVE (PARAPET) AT MASONRY OR CONCRETE

Page 10: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEI4050.DWG 11.8.10

EI4050 – HIGH EAVE (PARAPET) PANEL ABOVE AND BELOW

Page 11: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 08/02/17BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEI4070.DWG 11.8.11

EI4070 – HIGH EAVE (PARAPET) NON-STRUCTURAL

Page 12: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEE4010.DWG 11.8.12

RAKE DETAILSEE4010 – RAKE (SCULPTURED)

Page 13: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF4010.DWG 11.8.13

EF4010 – RAKE (PARAPET) WALL PANEL ABOVE

Page 14: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF4030.DWG 11.8.14

EF4030 – RAKE (PARAPET) AT MASONRY OR CONCRETE

Page 15: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 08/03/16BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEF4050.DWG 11.8.15

EF4050 – RAKE (PARAPET) RAFTER IN HIGH BUILDING

Page 16: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF4060.DWG 11.8.16

EF4060 – RAKE (PARAPET) RAFTER IN LOW BUILDING

Page 17: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEK4020.DWG 11.8.17

PARAPET GUTTER DETAILSEK4020 – PARAPET GUTTER – EAVE STRUT

Page 18: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEK4040.DWG 11.8.18

EK4040 – PARAPET GUTTER @ MASONRY OR CONCRETE – EAVE STRUT

Page 19: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15 BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEG4010.DWG 11.8.19

RIDGE DETAILSEG4010 – RIDGE CONDITION

Page 20: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEA5000.DWG 11.8.20

SR2 INSULATED ROOF PANELFASTENER REQUIREMENTSEA5000 – ROOF PANEL SIDE LAP

Page 21: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 12/22/17BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEA5021.DWG 11.8.21

EA5021 – ROOF END LAP

Page 22: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEED5310.DWG 11.8.22

LOW EAVE DETAILSED5310 – HORIZONTAL GUTTER WITH SCULPTURED RAKE

Page 23: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEH5006.DWG 11.8.23

HIGH EAVE DETAILSEH5006 – HIGH EAVE WITH WALL PANEL

Page 24: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 08/03/16BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEI5010.DWG 11.8.24

EI5010 – HIGH EAVE (PARAPET)

Page 25: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEI5030.DWG 11.8.25

EI5030 – HIGH EAVE (PARAPET) AT MASONRY OR CONCRETE

Page 26: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 08/03/2016BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEI5050.DWG 11.8.26

EI5050 – HIGH EAVE (PARAPET) PANEL ABOVE AND BELOW

Page 27: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 08/2/17BY: SAA CHK: EGB

DETAIL NAME IF APPLICABLEEI5070.DWG 11.8.27

EI5070 – HIGH EAVE (PARAPET) NON-STRUCTURAL

Page 28: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEE5010.DWG 11.8.28

RAKE DETAILSEE5010 – RAKE (SCULPTURED)

Page 29: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF5010.DWG 11.8.29

EF5010 – RAKE (PARAPET) WALL PANEL ABOVE

Page 30: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF5030.DWG 11.8.30

EF5030 – RAKE (PARAPET) AT MASONRY OR CONCRETE

Page 31: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF5050.DWG 11.8.31

EF5050 – RAKE (PARAPET) RAFTER IN HIGH BUILDING

Page 32: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEF5060.DWG 11.8.32

EF5060 – RAKE (PARAPET) RAFTER IN LOW BUILDING

Page 33: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEK5020.DWG 11.8.33

PARAPET GUTTER DETAILSEK5020 – PARAPET GUTTER – EAVE STRUT

Page 34: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEK5040.DWG 11.8.34

EK5040 – PARAPET GUTTER @ MASONRY OR CONCRETE – EAVE STRUT

Page 35: HR3 INSULATED ROOF PANEL4 FASTENER REQUIREMENTS4 … · ek4020.dwg 11.8.17 parapet gutter details ek4020 – parapet gutter – eave strut. last revision date: 02/16/15 by: ak chk:

LAST REVISIONDATE: 02/16/15 BY: AK CHK: EGB

DETAIL NAME IF APPLICABLEEG5010.DWG 11.8.35

RIDGE DETAILSEG5010 – RIDGE CONDITION


Top Related