GENERATION FOUR ENGITECH LTD.
HT- 650 FHT- 650 FHT- 650 FHigh Temprature Chain Oil
www.hitechsolution.co.in
GENERATION FOUR ENGITECH LTD. IM
PO
RTIN
G
FORMULATIN
GMARKETING
DEL
IVER
ING
ANALYZINGNEEDS
Profile
Our Collaboration
SOURCE EXPLORER Ltd.
St Box No : 91642,Nathan Road.
TSIM SHATSUI, Hongkong.
GENERATION FOUR ENGITECH LTD.
Wait a sec!!!!!
Advance High Temp. Chain Oil Technology
Searching For Efficient High Temp. Chain Oil???Which can provide :• Protection from Chain Damages • Maintain Low Ampere Load• No Carbon Residue Problem• High Lubricity and Film Strength Then..... go for Hi-Tech HT 650F
Our Product
�Speed� �Innovation� �Excellence"
100% SyntheticBase Oil
Preparation
No Carbon ResidueProblem
Added AdvanceFriction Modifier
High Themal &OxidationStability
Low Volatility
TakifyingAdvantage
Hi- Tech Hi- Tech HT 650 FHT 650 FHi- Tech
HT 650 FHi- Tech Hi- Tech
HT 650 FHT 650 FHi- Tech
HT 650 FHigh Temp. Chain Oil
GENERATION FOUR ENGITECH LTD.
The G4’s DNA ?
Physical Properties
Composition
Mixture of synthetic Esters(100%)
Appearance
BrightGolden Orange
300°C572 °F
Max. Bulk Chamber Temp.
-10°C 14 °F
Pour Point
<90 ppm
Moisture content
Total Acid Numbers
0.01 mg KOH/g
Density
0.96 g/ml
Metal Compitibility (Corrosion)
Cast Iron - PassBronze - PassSteel - Pass
Flash point
(ASTM D-92)287°C548 °F
oat 40 c - 220 cstoat 100 c - 18 cst
oKinematic Viscosity @ 40 C
GENERATION FOUR ENGITECH LTD.
GENERATION FOUR ENGITECH LTD.
Under Standing & Advantages of HT‐650F
High Temp. Oxidation & Thermal Stability
Some non standard chain lubricants have a tendency to produce carbonaceus deposit and residues at elevated temperatures due to high oxidation these residues can block clearances, jam chain, rollers and make rapid wear to occur. because of our advance 100% Synthetic base fluids closed molecular structure the process of oxidation is greatly reduces. Thus carbon varnish and sludge deposits formed due to high temperature operation are negligible and user of our HT 650 F will get a great advantage.
Low Volatility
The low volatility technology used in our advance high temperature chain oil results in lower top-up requirements.
High Viscosity Index
This results in a minimum change in viscosity with temperature. the proper viscosity for proper chain lubricant is provided regardless of temperature and oil film withstand extreme pressure.
Excellent Lubricity
The technology used in our high temperature chain lube provides the lubricant with outstanding load carrying capabilities, films strength and anti-wear properties, this results in enhanced chain life.
Main Chain
Bottom
Pin
Entry Rail
Middle Rail
Chain Side View
GENERATION FOUR ENGITECH LTD.
Reduced Fire Possibilities
Because of low volatility & low carbon forming tendencies and their relatively high flash, fire and auto ignition points, the plant using HT 650 F is more safer in fire hazards.
Energy EfficiencySmokeless high temp chain lube, low volatility characteristics, low carbon forming tendencies and advance friction modifier results in reduction of drag and friction on the chain mechanisms. This results in a significant reduction in starting loads and peak power demand, thus providing a realistic power cost saving.
Baking Oven ChainsTenter Frame ChainsPaint and Ceramic Curing OvensDrying Oven ChainsKiln ChainsDrying & Finishing ChainsHeat Treatment ChainsHigh Temp. Tunnel ChainsChains for Fiber Optic CableLithographic OvensPlywood Drying Oven Glass Forming Equipment
HT‐650F Application ‐ Where a High Degree of Cleanliness is Required
Top LubeChain
Without Chain Oil
WithHT 650 F
Wear Test
Packing Availability
5 Ltr.
20 Ltr. (5Ltr. x 4)
210 Ltr.
GENERATION FOUR ENGITECH LTD.
How it Work
Friction means "resistance to relative motion between two bodies in contact" Our technologies mechanism of operation is based upon advance method of tribology that improves lubricity and load carrying capacity. this in turn, improves surface characteristics whiles simultaneously creating a stable chemical advantage boundary film on the contacting metal surfaces of equipment of which it is added the process of advance boundary films formation is achieved through a unique combination of long chain additives that are highly stable on high temperature
Advance Friction Modifiers are Polar Molecules having high affinity for metal surfaces and processing long alkyl chains.
Develop Advance Boundary Films
Reduces internal Heat
by that you will get long term Benefit
Chain Oil
Metal Particulates
Microsopic Flash
Contaminants
Lubrication Effects
V
Conventional LubricationF
Current Markets Chain OilF
V
Advance HT 650 FF
V
h
Develops lower coefficient of friction compare to other high temp. chain Oils
Oil Soluble TailAdditive
Polar Head
Testing Thermic Fluid India's Only Specialised Thermic Fluid Testing Lab Facility (Its true - Any lab can test your thermic fluid but you will get benefit only if test's are correct by conducted)
Above tests are essential ones and should be conducted every 4 months. We also undertake other tests relating to thermic fluids. For details contact :
Shri Dhansukh Jain - 092140 48652email : [email protected]
1. Send your Sample in clean, Contamination & moisture free bottle.
2. Send at least 750 ml to 1000ml of thermic fluid
3. It is better to draw sample through needle valve' while pump is running.
4. Throw 200 ml of oil and then collect the oil for sample testing.
5. For proper recommendation fill all columns in testing form.
6. Send Sample to -- Generation Four Engitech Ltd. Hitech Solution Mandeep Tower, Residency
R o a d , O p p . S a n k a l p Restaurant, Jodhpur (Raj)
Tel. : 0291-5107038 Mobile : 0 92140 486527. Guideline for Sending sample to
courier. A. Send Sample in Chemical
Sample Bottle Available in Indian Market.
B. Ensure that bottle/can is leakproof.
C. Fill the bottle 100% with no air.
D. Pack the sample in Square box with paper & plastics surrounding.
E. If your Packing is Poor, Courier will not accept the sample.
F. Write Proper Address in D e t a i l s w i t h P h o n e Numbers.
Guide Line O@40 C
Kinematic Viscosity
Flash point
ASTM D-92
Carbon Residue
Result are in %
Suspended Particle & Contamination
Increase in carbon will increase your fuel cost and decrease your machine performance. It is an economical test.
It reflects your fire risk, due to Thermic Fluid which is important for safety.
It is very Important test to check your fluids proper flow rate. i.e. how fas t i s hea t transfer.
We check your oil for suspended particle and contamination, whether parameter exceeds.
GENERATION FOUR ENGITECH LTD.
GENERATION FOUR ENGITECH LTD.
“Award presented by : Mrs. Shikha Sharma – MD and CEO, Axis Bank”“Award presented by : Mrs. Shikha Sharma – MD and CEO, Axis Bank”“Award accepted by: Mr. Dhansukh Chopra (Director) “Award accepted by: Mr. Dhansukh Chopra (Director)
and Mr. R. P. Vyas (Director) GFEL”and Mr. R. P. Vyas (Director) GFEL”
“Award presented by : Mrs. Shikha Sharma – MD and CEO, Axis Bank”“Award accepted by: Mr. Dhansukh Chopra (Director)
and Mr. R. P. Vyas (Director) GFEL”
AXIS BANK
BUSINESSGaurav
SME AWARDS 2012
Under Sector Under Sector �Chemical and Petrochemicals� �Chemical and Petrochemicals�
as Best as Best Micro Enterprise in IndiaMicro Enterprise in India
Under Sector �Chemical and Petrochemicals�
as Best Micro Enterprise in India
Third Party Recognition
GENERATION FOUR ENGITECH LTD.
Our Golden Clients
ADANIwilmar
ADANI WILMAR AGARWAL FOOD UDAIPUR ASHOKA CHEM FOOD ASHWIN VANASAPTI VAPI BIKAJI
BRINK FOODS BUNGE COOKWELL FOOD DABUR GOVERDHAN INDUSTRIES
JAGANNATH CHEM, NAWA JAYANTI AGRO, ALWAR JK TYRES JYOTHY LABORATORIES LTD.KANDLA ENERGY
AND CHEMICALS LTD.
KR FOODS LTD. KUBER FOODS LALIT HANS PROTEIN MANAKSIA LTD MARICO
MARUTI TEXTILES MAYUR UNIQUOTERS LTD. METRO PLYWOOD PVT. LTD. MOTHERLAND GARMENTS
MOTIF DECOR PANKAJ SALT INDUSTRIES, NAWA
PARAS VANASPATI
PVT. LTD. RAIPUR PAWAN AGRO INDUSTRIES PIDILITE
PURTI GROUP RACHNA PLASTICIZERS RISHABH RESINS RUCHI SOYA LTD. SK OIL INDUSTRIES
SNR RECLAMATIONS PVT. LTD. SABOO SODIUM SAHIB SYNTHETICS SHREE NAMAK SOMI CONVEYOR BELT
SUPER FLOORINGS TEX CORP DELHI TIPCO VE COMMERCIAL VEHICLES LTD. VIJAY SOLVEX LTD
VOLTAMP TRANSFORMERS LIMITED YETI POLYCHEM, NEPAL MARUDHAR PAINTS HOMTEK AGRO INDIA AGRO TEC FOOD LTD.
sAhIB synthEtICs
SILICON JEWEL INDUSTRIES
GENERATION FOUR ENGITECH LTD.
Actual Photographs of Generation Four Engitech Ltd. Manufacturing Plant
StorageStorageStorage
Plant’s Wide ViewPlant’s Wide ViewPlant’s Wide View
Additive Blending VesselsAdditive Blending VesselsAdditive Blending Vessels
2000 Ltr.2000 Ltr.2000 Ltr.
25000 Ltr. 2 Blending Vessels25000 Ltr. 2 Blending Vessels25000 Ltr. 2 Blending Vesselswith Hot & Cold Facilitywith Hot & Cold Facilitywith Hot & Cold Facility
3000 Ltr.3000 Ltr.3000 Ltr. 3000 Ltr.3000 Ltr.3000 Ltr.
GENERATION FOUR ENGITECH LTD.
Actual Photographs of Generation Four Engitech Ltd. Regd. Office
Office FrontOffice FrontOffice Front
Director’s RoomDirector’s RoomDirector’s Room
Top ManagementTop ManagementTop Management
Back OfficeBack OfficeBack Office
Conference RoomConference RoomConference Room
Accounts RoomAccounts RoomAccounts Room
GENERATION FOUR ENGITECH LTD.
Silicon Green 100% Synthetic Thermic Fluid
High Oxidation Stability
Reduces Problemof Low & High
Boilers
Almost NegligibleCarbon Contents
Lower Top UpRequirement
Has Long Life
High Thermal Stability
Hi- Tech Hi- Tech Therm 60Therm 60Hi- Tech
Therm 60Hi- Tech Hi- Tech
Therm 60Therm 60Hi- Tech
Therm 60
Why to use Hi-Tech Therm 60 as new fill or Top-up in your thermic fluid heater.1. Less tendency to increase viscosity 2. Very low carbon residue3. Carbon protection technology.
GENERATION FOUR ENGITECH LTD.
Technical Support (Multi Tiered Technical Support)
Our technical support services are divided into III tier in order to better serve our customer base.
TIER - I 1. This is initial support
level responsible for basic customer issues.
2. It starts with determining the customer’s issue by analyzing the sample.
3. Once identification of the underlying problem is done “ The specialist begins sorting through the possible solutions available
TIER II 1. More in depth technical support level2. Administrative level support.3. Include onsite inspection of system design & networking.4. Compatibility related issues in case of Top-ups on other fluids
TIER III1. Highest level of support.2. Back end support for handling the most difficult or advanced
problem.
Experienced technical service specialist can answer your questions regarding heat transfer fluid selection, system start-ups, system design, and operational issues.call us on:__________or contact : [email protected]
Technical Service
Generation Four Engitech Ltd. - Hitech SolutionMandeep Tower, Residency Road, Opp. Sankalp Restaurant, Jodhpur (Raj)Tel. : 0291-5107038 Fax : 0291-5109091 Mobile : 0 92140 48652
We�are�located�at:
Contact Details :
Admn. Office :Hitech SolutionMumbai Bazar, 387-Last Bus Stop, Park Side, Vikhroli (W) Mumbai -79
Regd. Office :
Collaboration with :SOURCE EXPLORER Ltd.St Box No : 91642,Nathan Road. TSIM SHATSUI, Hongkong.
Local Representative :
Disclaimer : Generation Four Engitech Ltd. makes every effort to ensure that the information and data provided are correct. However we can accept no liability or guarantee that the information and data provided is up-to-date, correct and complete. Nor is Generation Four Engitech Ltd. responsible for the contents of such reference information. Generation Four Engitech Ltd. reserves the right to modify of supplement the information or data provided without prior notice.
[email protected] [email protected] [email protected]
Mfg. Plant :Generation Four Engitech Ltd.Plot No. 25-A, Raipur Sahakari Industrial Area, Raipur Bhagwanpur, Roorkee, Uttarakhand. Mobile : 09760366343
www.hitechsolution.co.inwww.g4ltd.co.in