0 0
ODU Alarm and Status
Indication Category Descriptions Severity
TXPWR ALM Alarm The TX PWR is lower than 3 dB. MJ
TX INPUT ALM Alarm The TX IF signal become out of range from
-29 dBm 5 dB.
MJ
RXLEV ALM Alarm The reception level become lower than -72dBm ~ -94dBm level.(It
depends on the modulation system and bit rates).
MJ
ODU CPU / Cable
Open Alarm
CPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken
or is not connected.
MJ
MUTE STATUS Status Indicates the control status of the ODU TX power output. When the TX
power is set to Mute, Status is issued. -
LO REF Alarm Loss of Ref LO signal of ODU. MN
TX SW Status Status Radio interface TX SW usage state in 1+1 HS Redundant configuration -
ODU ALM Alarm Indicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM,
ODU SELF CHECK ALM occurrence MJ
ODU TOTAL ALM Alarm Indicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU
CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.
Highest
severity will
be displayed
ATPC Power
Mode Status
ATPC control signal fault (90sec) as well as MAX Power continuation
90sec -
ODU TYPE
MISMATCH Alarm
Indicate connected ODU type is not supported at iPASOLINK system, or
ODU type cannot use in provisioned modulation setting. MJ
ODU PS ALM Alarm ALM in a case of Power supply interruption to ODU. MJ
ODUPS SET
STATUS
Status Status indication of the protection switch for ODU power supplies -
1 1
Modem Alarm and Status
Indication Category Descriptions Severity
Unequipped (MODEM-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(MODEM-A) Alarm The equipped type of interface is different from configured type. MJ
Communication FAIL(MODEM-A) Alarm Communication failure of equipment internal control communication. MJ
Module(MODEM-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
RXSW STATUS Status Radio interface RX SW usage state in Redundant configuration -
LOSS OF FRAME Alarm Loss of Frame at radio side. MJ
FRAME ID Alarm Frame ID (route differentiation ID) MJ
HIBER ALM Alarm Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5) MJ
LOBER ALM Alarm Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9) MN
EARLY WARNING Alarm Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9) MN
MOD Alarm Indicates the operating status of the MOD. When any failure occurs in the modulator section, Alarm is issued. MJ
IF CABLE SHORT Alarm IF cable between IDU - ODU is in short condition. MJ
INPHASE. Status In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase
condition. In this condition, hitless switch over is available.
-
L2SYNC LOSS Alarm Loss of frame synchronization of GFP frames on MODEM port. MJ
RDI Alarm RDI indication reception alarm on MODEM port MJ
UAE. Alarm UAE alarm. Indicates the occurrence of an Unavailable state. MN
TDM/AMR Range Mismatch Alarm Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or
mismatch condition of selected RX AMR modulation range and TX AMR modulation range.
MJ
TX SW Reverse Request Status TXSW request signal receiving condition from the opposite station: -
TX SW Lock in Status Status TXSW Lockin state -
Unlocked Alarm Wireless synchronization status of the local side. MJ
MODEM PS OFF Status Indicate power off condition of power switch which is in front of MODEM-A card. -
2 2
STM-1 Alarm and Status
Indication Category Descriptions Severity
Unequipped (STM1-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(STM1-A) Alarm The equipped type of interface is different from configured type. MJ
Communication
FAIL(STM1-A) Alarm Communication failure of equipment internal control communication. MJ
Module(STM1-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
SNCP PPS-FAIL Alarm. SNCP Path Protection Failure MJ
SNCP Protection Status Status SNCP Path Protection Status indication which indicates [FS, SF, SD, MS, NR] condition. -
APS Protection Status Status APS Line Protection Status indication which indicates {FS,SF,SD,MS,NR} condition. -
APS Lock-in Status Status APS protection Lock-in Condition. -
SFP_Type Mismatch
(STM1) Alarm Mismatch between SFP on LCT and installed SFP. MJ
SFP Unequipped (STM1) Alarm A SFP is removed. MJ
STM-1LOS Alarm LOS detection on STM-1 Optical port. MJ
STM-1 TF Alarm Transmit Failure detection on STM-1 optical port. MJ
RS LOF Alarm SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port. MJ
RS TIM Alarm Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port. MJ
RS EXC Alarm B1 Byte error occurrence in RS (Regenerator Section) on STM-1 port. MJ
RS DEG Alarm B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port. MN
MS AIS Alarm AIS detection in MS (Multiplex Section) on STM-1 port. MJ
MS RDI Alarm Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port. MJ
AU AIS Alarm AIS detection in AU (Administrative Unit) on STM-1 port. MJ
3 3
STM-1 Alarm and Status
Indication Category Descriptions Severity
AU LOP Alarm Loss of AU pointer happens on STM-1 port. MJ
HP UNEQ Alarm HOP (Higher Order Path) Unequipped occurrence on STM-1 port. MJ
HP TIM Alarm HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port. MJ
HP-PLM Alarm Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port. MJ
HP-RDI Alarm RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port. MJ
HP-LOM Alarm Loss of Multi-Frame on STM-1 port. MJ
TU -AIS Alarm In TU (Tributary Unit), AIS detection on STM-1 port. MJ
TU -LOP Alarm Loss of TU Pointer on STM-1 port. MJ
LP -UNEQ. Alarm LP (Lower Order Path) Unequipped occurrence on STM-1 port. MJ
LP RDI Alarm Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port. MJ
LP PLM Alarm Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port. MJ
ALS Status Indication of automatic laser shutdown condition at STM-1 optical port. -
RS UAS Status Status UAS status indication on STM port (Repeater Section) -
STM-1 AIS Generated Status AIS generation condition on STM port. -
PJE Status Pointer justification Event indication at STM port. -
4 4
16E1 alarm and Status
Indication Category Descriptions Severity
Unequipped (16E1) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(16E1) Alarm The equipped type of interface is different from configured type. MJ
Communication FAIL(16E1) Alarm Communication failure of equipment internal control communication. MJ
Module(16E1) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
E1 LOS Alarm No signal input on E1 port MJ
E1 AIS Status ALARM/Status category can change according to " AIS Received Condition
Setting
MJ / -
Usage Error Alarm Unused E1 CH input signal detection. MN
E1 AIS Generated Status AIS generation condition on every E1 Channels. -
5 5
AUX-A Option Card
Indication Category Descriptions Severity
Unequipped (AUX-A) Alarm Reserved and installed optional package is removed
from optional slot.
MJ
Type Mismatch(AUX-A) Alarm The equipped type of interface is different from
configured type.
MJ
Communication
FAIL(AUX-A)
Alarm Communication failure of equipment internal control
communication.
MJ
Module(AUX-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX
direction from STM-1 Card.
MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX
direction from STM-1 Card.
MJ
Item Name (Input-x)
Item Name (Cluster-x)
Status/
Alarm
HKA Status Indication {Alarm, Normal} for every
HKA input.
- or
Severity selectable
Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -
6 6
GbE-A option card
Indication Category Descriptions Severity
Unequipped (GBE-A) Alarm Reserved and installed optional package is
removed from optional slot.
MJ
Type Mismatch(GBE-
A)
Alarm The equipped type of interface is different
from configured type.
MJ
Communication
FAIL(GBE-A)
Alarm Communication failure of equipment
internal control communication.
MJ
Module(GBE-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition
in TX direction from STM-1 Card..
MJ
BUS ERROR RX Alarm Data communication BUS failure condition
in RX direction from STM-1 Card..
MJ
SFP_Type Mismatch
(ETH)
Alarm Mismatch between SFP on LCT and
installed SFP.
MJ
SFP Unequipped
(ETH)
Alarm A SFP is removed. MJ
LAN LINK Alarm LINK of the LAN Port is disconnected. MJ
Speed & Duplex Status LAN Port setting (Speed&Duplex) -
7 7
Equipment Common alarm and Status-1
Indication Category Descriptions Severity
MODULE (Main Board) Alarm Equipment fault MJ
BUS ERROR Alarm Data communication BUS failure condition. MJ
Unequipped (PS) Alarm Installed Power Supply Module is removed from PS slot. MJ
Power Supply Alarm Alarm in case of power failure. MJ
FAN Fail Alarm FAN failure MJ
Unequipped (FAN) Alarm Installed FAN Module is removed from FAN slot. MJ
Unequipped (CLK2M) Alarm Installed CLK2M Module is removed from Main Card. MJ
Type Mismatch (CLK2M) Alarm The equipped type of interface is different from configured type. MJ
IDU CPU Alarm Alarm. IDU CPU Alarm MN
Memory Failure Alarm Detection of memory failure MJ
USB Failure Alarm USB memory failure indication MJ
Temperature Alarm The temperature is over the threshold MN
Maintenance Status Maintenance declaration. -
CLK FAIL Alarm Reference Clock Failed. MN
CLK Drift Alarm Reference Clock source Frequency drift condition MN
LTI Alarm Loss of all incoming timing source MJ
CLK Status Changed Status Reference clock change status
(1) (Locked Ref1)
(2) (Locked Ref2)
(3) (Locked Ref3)
(4) Holdover
(5) Freerun
-
SSM FAIL Alarm Received Sync Status Message value is in unstable condition. MN
Quality Level Status Received quality level condition of each timing source. -
Squelch Status The condition of External CLK Output is in squelch condition. -
8 8
Equipment common Alarm and Status -2
Indication Category Descriptions Severity
EXT CLK Condition Status Condition level of External CLK output. -
EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN
EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input. MN
EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN
EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output. MJ
Item Name (Input-x)
Item Name (Cluster-x)
Status/
Alarm HKA Status Indication {Alarm, Normal} for every HKA input.
- or Severity
selectable
Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -
E1 LOS Alarm No signal input on E1 port MJ
E1 AIS Status
PDH AIS ALARM/Status category can change according to " AIS Received Condition Setting MJ / -
Usage Error Alarm Unused E1 CH input signal detection. MN
E1 AIS Generated Status AIS generation condition on every E1 Channels. -
ETH LOS Alarm LOS detection at Optical Ethernet port. MJ
ETH TF Alarm Transmit Fail detection at Optical Ethernet port. MJ
SFP_Type Mismatch (ETH) Alarm Mismatch between SFP on LCT and installed SFP. MJ
SFP Unequipped (ETH) Alarm A SFP is removed. MJ
LAN LINK Alarm LINK of the LAN Port is disconnected. MJ
Speed & Duplex Status LAN Port setting (Speed&Duplex) -
ETH-OAM LOC Alarm MJ
ETH-OAM Mismerge Alarm Ether OAM Mismatch Detection notice. MN
ETH-OAM Unexpected Period Alarm Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice MN
ETH-OAM RDI Alarm Ether OAM RDI reception detection notice MJ
9 9
Equipment common Alarm and Status -3
Indication Category Descriptions Severity
RSTP New Root Bridge Detect Status The notice in which new RootBridge was detected at the time of SpanningTree processing -
RSTP Topology Changed Status The notice in which a Topology change was detected at the time of SpanningTree processing -
RSTP Protocol Migration Status
The notice which received a Bridge protocol Data Units different in classification of RSTP/STP at the
time of SpanningTree processing -
RSTP Invalid BPDU Received Status Invalid BPDU message at the time of SpanningTree processing -
LLF Message Timeout Status
Loss of a conditional signaling in which the LLF control signal should be received continuously from
the opposite radio equipment.
LLF Status LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN. -
IDU TOTAL ALM Alarm IDU TOTAL ALM
The highest
Severity will
be reported
Total FDB Full Status The number of DynamicEntryDynamic Entry in L2Switch has reached the maximum number.
FDB Full Status FDB Full indication specified per VLAN basis.
10
ABBREVIATIONS-1
ACAP Adjacent Channel Alternate
Polarization
ACCP Adjacent Channel Co-Polarization
ACK Acknowledgement
AGC Automatic Gain Control
AIS Alarm Indication Signal
ALM Alarm
ALS Auto Laser Shutdown
AMR Adaptive Modulation Radio
ANT, Ant. Antenna
APS Automatic Protection Switch
ATT Attenuator
ATPC Automatic Transmitter Power Control
AU Administrative Unit
AUX Auxiliary
Ave Average
BBE Background Block Error
BER Bit Error Rate
BPF Band Pass Filter
BS Base Station
BSC Base Station Controller
BTS Base Transceiver Station
CAPEX Capital Expenditure
CBS Committed Burst Size
CCDP Co-Channel Dual Polarization
CCM Continuity Check Message
CEPT Conference of European Postal &
Telecommunication Administration
CIR Committed Information Rate
CKT Circuit
CLK Clock
CMF Channel Mismatch Failure
CMI Coded Mark Inversion
CONV Converter
CORBA Common Object Request Broker
Architecture
CoS Class of Service
CPU Central Processing Unit
CR Critical
CRC Cyclic Redundancy Check
CS Channel Separation
CTRL Control
CV near end Code Violation
CW Carrier Wave
DA Destination Address
DADE Differential Absolute Delay Equalizer
DB Database
DC Direct Current
DCN Data Communication Network
DEG Degraded
DEI Drop Eligible Indicator
DEM Demodulator
Des(Dest) Destination
DI Data-in
DL Download
DM Delay Measurement
DMM Delay Measurement Message
DMR Delay Measurement Reply
DO Data-out
DSCP Differentiated Services Code Point
DUP Duplexer
DXC Digital Cross Connect
E1 E-carrier level 1
EBS Express Burst Size
EIR Excess Information Rate
EMC Electro Magnetic Compatibility
EML Element Management Layer
EMS Element Management System
EOW C Order Wire
EPS ETH-Protection Switch
EQL Equalizer
ERP ETH-Ring Protection Switch
ES Errored Seconds
ETH-CC ETH-Continuity Check function
ETH-LB ETH-Loopback function
ETH-LBM ETH-Loopback Message
ETH-LBR ETH-Loopback Reply
ETH-LB ETH-Loopback function
ETH-LT ETH- Link Trace function
ETH-LTM ETH-Link Trace Message
ETH-LTR ETH-Link Trace Reply
ETH-OAM Ethernet Operations, Administration
and Maintenance
11
ABBREVIATIONS-2
ETH-OAM LB ETH-OAM Loopback
ETH-OAM LT ETH-OAM Link Trace
ETH-RDI ETH-Remote Defect Indication function
ETSI European Telecommunications
Standards Institute
EXC Electrical Cross Connect
E-to-E. End-to-End
Fail Failure
F/B Front Back Ratio
FCS Frame Check Sequence
FDB Forwarding Database
FE Fast Ethernet
FEC Forward Error Correction
FEBBE Far End Background Block Error
FEES Far End Errored Seconds
FESES Far End Severely Errored Seconds
FEUAS Far End Unavailable Seconds
FPGA Field Programmable Gate Array
F/W Firmware
GbE, GBE Gigabit Ethernet
3GPP Third Generation Partnership Project
GUI Graphical User Interface
H Horizontal
HDB High Density Bipolar
HK House Keeping
HP Higher order Path
HYB Hybrid
H/W Hardware
ID Identification
IDU Indoor Unit
IE Internet Explorer
IEC International Electro technical
Commission
IEEE Institute of Electrical and Electronics
Engineers
I/F Interface
IF Intermediate Frequency
IHG iPASOLINK High Grade
IN Input
INTFC Interface
I/O Input/Output
IP Internet Protocol
ITU International Telecommunication Union
ITU-R Radio Communication Sector of ITU
ITU-T Telecommunication Sector of ITU
L2SW Layer2-Switch
LAN Local Area Network
LB Loopback
LBM Loopback Message
LCD Loss of Cell Delineation
LCT Local Craft Terminal
LDPC Low Density Parity Check
LED Light Emitting Diode
Lev. Level
LLF Link Loss Forwarding
LM Loss Measurement
LMM Loss Measurement Message
LNA Low Noise Amplifier
LO Local Oscillator
LOC Loss of Continuity
LOF Loss of Frame
LOM Loss of Multiframe
LOP Loss of Pointer
LO REF Local Reference Signal Loss
LOS Loss of Signal
LP Lower order Path
LPM Link Performance Monitor
LT Link Trace
LTI Loss of incoming Timing Input
LTM Link Trace Message
MAC Media Access Control
MAIN Main
MAINT Maintenance
MAX Maximum
Mdev Mean Deviation
MDCPU MODEM CPU
MDI Medium Dependent Interface
MDIX Medium Dependent Interface
Crossover
MD4 Message Digest Algorithm 4
MD5 Message Digest Algorithm 5
MEG Maintenance Entity Group
MEM Memory
MEP MEG End Point
12
ABBREVIATIONS-3
MIN Minimum
MIP Maintenance Intermediate Point
MIX Mixer
MJ Major
MMC Multi Media Card
MME Mobility Management Entity
MMG Mismerge
MN Minor
MOD Modulator
MODEM Modulator Demodulator
MON Monitor
MPX Multiplexer
MS Multiplex Section
MSC Mobile Switching Center
MSDU MAC Service Data Unit
MSP Multiplex Section Protection
MTBF Mean Time Between Failure
MTPC Manual Transmitter Power Control
MUX Multiplexing Equipment
N/A Not Applicable
NBI Northbound Interface
NE Network Element
NML Network Management Layer
NMS Network Management System
OAM Operation Administration and
Maintenance
OCR Occur
Octs Octets
ODU Out-Door Unit
OFS Out of Frame Second
OMT Ortho-Mode Transducer
OPEX Operational expenditure
OPP Opposite
OPR Operation
OPT Optical
OSPF Open Shortest Path First
OSS Operation Support System
OUT Output
OW Oder Wire
PA Power Amplifier
PBR Pressurizable Type B, flange profile
square Rectangular
PCP Priority Code Point
PDH Plesiochronous Digital Hierarchy
PDU Protocol Data Unit
PGM Program
PHY Physical
PIR Peak Information Rate
PJE Pointer Justification Event
PJE-N Pointer Justification Event Negative Stuff
PJE-P Pointer Justification Event Positive Stuff
PKG Package
Pkts Packets
PLM Payload Label Mismatch
PMC PASOLINK Management Card
PMON Performance Monitor
PNMSj PASOLINK Network Management
System Java Version
PPI PDH PHY Interface
ppm parts per million
PPP Point-to-Point Protocol
PPS Path Protection Switch
PQ Priority Queuing
PRM Parameter
PROT Protection
PS Power Supply
PSC Protection Switching Counts
PSD Protection Switching Duration
PWR Power
QAM Quadrature Amplitude Modulation
QoS Quality of Service
QPSK Quadrature Phase Shift Keying
RCVR Recover
REF Reference
REM Remote
RDI Remote Defect Indication
RF Radio Frequency
RFS Radio Frequency Systems
RL Relay
RMON Remote Network Monitoring
RNC Radio Network Controller
13
ABBREVIATIONS-4
RPL Ring Protection Link
RS Regenerator Section
RS-232 Recommended Standard 232
RSL Received Signal Level
RST Regenerator Section Termination
RSTP Rapid Spanning Tree Protocol
RX Receiver
SC Service Channel
SD Space Diversity
SDH Synchronous Digital Hierarchy
SEG Segment
SEP Severely Errored Period
SES Severely Errored Seconds
SFP Small Form factor Pluggable
SGMI Security Gateway Management
Interface
SMS Synchronous Multiplexing System
SMU Source Measure Unit
SNCP Sub-network Connection Protection
SNMP Simple Network Management Protocol
SP Strict Priority
SPD Speed
SRC Source MAC Address
STAT Status
STD Standard
STM Synchronous Transport Module
STP Spanning Tree Protocol
SUB Substitute
SW Switch
S/W Software
SWG Switch Group
SYNC Synchronous
TCI Tag Control Information
TCN Threshold Crossing Notification
TDM Time Division Multiplex
TDMoP TDM over Packet
TEMP Temperature
TERM Terminal
TF Transmit Fail
TIM Trace Identifier Mismatch
TLV Type Length Value
TM Through Mode
TNC Threaded Neil Councilman
ToS Type of Service
TPID Tag Protocol Identifier
TQC Total Quality Control
TTL Time To Live
TU Tributary Unit
TX Transmitter
UAE UAS Event
UAS Unavailable Seconds
UL Upload
UNEQ Unequipped
UNEXP Unexpected
Unicast DMR Unicast Delay Measurement Reply
UNM Unexpected MEP
UNP Unexpected Period
USB Universal Serial Bus
V Vertical
V Volt
VC Virtual Channel
VLAN Virtual LAN
VP Virtual Path
VPN Virtual Private Network
VSWR Voltage Standing Wave Ratio
WDM Wavelength Division Multiplexing
Web World Wide Web
WG Waveguide
WR Warning
WRR Weighted Round Robin
WS Wayside
XCTRL XPIC Control
X-DEM XPIC Demodulator
XFP 10(X) Gigabit Small Form Factor
Pluggable
XIF XPIC IF
XPD Cross Polarization Discrimination Ratio
XPIC Cross Polarization Interference
Canceller
XREF XPIC Reference