+ All Categories
Transcript
Page 1: ITM-23Q IntelliMotor Quick Start Guide · Form QSG-ITM-23Q-020D Bimba Manufacturing Company P.O. Box 68 Monee, Illinois 60449-0068 Phone: 708-534-8544 Toll Free: 800-44-BIMBA Fax:

RequirementsTo begin, make sure you have the following equipment:

• Asmallflatbladescrewdriverfortighteningtheconnectors(Bimbascrewdriverincluded).

• ApersonalcomputerrunningMicrosoftWindows98,2000,ME,NT,XP,Vista,7(32and64bit),or8.

• IQ®steppersoftware(availableatwww.bimba.com).

• ForRS-232models:aBimbaprogrammingcable(included).

• ForRS-485models:aRS-422orRS-485portoradapterforyourPC(seepage2forrecommendedRS-485adapter).

• Formoredetailedinformation,pleasedownloadandreadtheITM-23QHardwareManualavailableatwww.bimba.com.

Step 1

Step 2

ITM-23Q IntelliMotor® Quick Start Guide

Quick Start Guide

a)DownloadandinstalltheIQ®steppersoftware.

b) Launchthesoftwarebyclicking: Start/AllPrograms/Bimba/IQ® stepper

c) SelectthecorrectCOMportusingthedropdownlist.

d) ConnectthedrivetoyourPCusingtheRS-232programmingcableor RS-422/485adaptor.

WirethedrivetotheDCpowersource. (donotapplypoweruntilallconnectionstothedrivehavebeenmade) Note,theITM-23QacceptDCvoltagesfrom24-48Vdc. (RecommendedBimbaP/NPWR-150A24) Ifusinganexternalfuse,werecommendthefollowing: ITM-23Q:3AG,4amp(Littlefuse313004P) SeeBimbaITM-23QHardwareManualformoreinformationabout powersupplyandfuseselection.

+

-

STEP+STEP-DIR+DIR-EN+EN-OUT+OUT-+5VAINGND

Step 2

Page 2: ITM-23Q IntelliMotor Quick Start Guide · Form QSG-ITM-23Q-020D Bimba Manufacturing Company P.O. Box 68 Monee, Illinois 60449-0068 Phone: 708-534-8544 Toll Free: 800-44-BIMBA Fax:

CONTENTS

Step 3

Form QSG-ITM-23Q-020D

Bimba Manufacturing Company

P.O. Box 68 Monee, Illinois 60449-0068

Phone: 708-534-8544 Toll Free: 800-44-BIMBA Fax: 708-235-2014

Email: [email protected] www.bimba.com

For complete information, refer to Bimba IntelliMotor® ITM-23Q Hardware Manual. If you have any questions or com-ments, please call Bimba Customer Support: 800.442.4622, or visit us online at www.bimba.com.

a) Applypowertothedrive.Thedrivemodelandfirmwarerevisionshould beautomaticallydisplayed.Iftheyarenot,checkthecomportsetting.

b) FollowtheconfigurationinstructionsintheIQ®stepperhelpscreens. The IQ®steppersoftwarecanbeusedtosetupyourdrivetooperatein severaldifferentmodesincluding:Pulse&Direction,AnalogVelocity, IQ®Programmer,andSCL.

c) IQ® stepperincludesaselftestoption(undertheDrivemenu)to verifythattheITMandpowersupplyarecorrectlywiredandconfigured.

Recommended RS-485 Adapter

USB-COMi-M (P/N 8500-003) or equivalent

• NotavailablefromBimba;

• ConvertsRS-422andRS-485toUSB

ForfourwireRS-485,setSW2toOFFandSW1,3,4toON.Onthe USB-COMi-Mscrewterminalconnector:

• Connectpin1toRX-

• Connectpin2toRX+

• Connectpin3toTX+

• Connectpin4toTX-

• Connectpin6toGND

• TheDB-9connectorisnotused

1ON 2 3 4

4 WireRS-485