LightMix� Modular Assays & PanelsSimplify your research with panels ready-to-use Real-Time-PCR assays for LightCycler� and cobas z 480 instruments
Panel Target Product Name Channel Roche Cat.No.*
Gas
troe
nter
itis
Gastro – Virus
vr Sapovirus 500 07396821001
vr Norovirus GG1 500 07374348001
vr Norovirus GG1 530 07374321001
vr Norovirus GG2 530 07374364001
vr Rotavirus A 580 07374313001
vr Adenovirus F (40,41) 610 07374305001
vr Enterovirus 640 07396805001
vr Astrovirus 640 07374291001
Gastro – Parasites
pa Entamoeba histolytica 500 07041896001
pa Giardia 530 07042230001
pa Dientamoeba 580 07042248001
pa Cryptosporidium 610 07042256001
pa Blastocystis 640 07042264001
Gastro – Bacteria
bc Yersinia 500 07041837001
bc Campylobacter 530 07041845001
bc Shigella 580 07041853001
bc Salmonella 610 07041861001
bc Plesiomonas 640 07041870001
bc Aeromonas 640 07041829001
EHEC
EHEC
bc STX1-EHEC 530 07094248001
bc STX2-EHEC 580 07094256001
bc EAE-EHEC 610 07094213001
Emer
genc
y P
aram
eter
Emergency Parameter
vr Ebola Zaire (2014) 530 07383428001
vr Coronavirus SA1 upstream E-gene 530 06950302001
vr Corona SA1 Orf1a 530 07088833001
Car
bape
nem
ase
Carbapenemase – CRE (carbapenem-resistant enterobacteriaceae)
bc VIM 500 07042370001
bc GES 530 07042337001
bc NDM1 530 07042299001
bc IMP 580 07042353001
bc OXA-48 580 07042302001
bc VIM 610 07042361001
bc KPC 610 07042272001
bc IMP 640 07042345001
COBAS Z, LIGHTCYCLER and TAQMAN are trademarks of Roche.
Roche Diagnostics Deutschland GmbHSandhofer Straße 11668305 Mannheim/Germany
© 2014 Roche Diagnostics. Alle Rechte vorbehalten.
www.lifescience.roche.com
LightMix� Modular assays contain pre-mixed primers and hydrolysis probes, positive controls and instructions for use. Individual assays may be used to build a custom panel which can be multiplexed for up a 6-plex (including an internal control or a spiked extraction control). Additional Roche Applied Science re-agents for sample extraction, reverse transcription and / or amplification might be required (as mentioned in the respective LightMix� Modular assays instructions). These products are designated to be used with LightCycler� and cobas z 480 instruments only.
* Format: Kits with reagents for 96 PCR reactions (à 20 μl)Target: pa: parasite; bc: bacteria; vr: virus; IC: Internal Control; EC: Extraction Control
Panel Target Product Name Channel Roche Cat.No.*
Res
pira
tory
Respiratory – Virus
vr Influenza A 530 07041594001
vr Influenza B 580 07041616001
vr Influenza A H1 (H1N1) 500 07409206001
vr Influenza A H7 (H7N9) 530 07041578001
New
born Newborn
bc TREC 530 07093861001
bc KREC 610 07093896001
N/C
B
act Non-Culturable Bacteria
bc Tropheryma whipplei 530 07094272001
Con
trol
Rea
ctio
ns
Control Reactions
IC PhHV Internal Control (DNA) 660 07093853001
EC PhHV spiked Extraction Control (DNA) 660 07093802001
EC MSTN Extraction Control (RNA) 580 06296874001
EC MSTN Extraction Control (RNA) 660 07225253001
EC EAV Extraction Control (RNA) 660 07374330001
Mastermix Reactions Roche Cat.No.
wit
h C
ontr
ol EC RNA Process Control Kit 200 07099622001
600 07099592001
RNA Process Control Detection Kit (Refill)
400 07099606001
wit
hout
Con
trol
LightCycler� Multiplex RNA Virus Master
200 06754155001
1 000 07083173001
LightCycler� 480 Probes Master 500 04707494001
5 000 04887301001
LightCycler� 480 Probes Master
LightCycler� Multiplex RNA Virus Master
RNA Process Control Kit
LightMix� Modular Kits are developed and manufactured by TIB MOLBIOL GmbH, Berlin, Germany, and distributed through Roche Diagnostics.
For Life Science Research Use Only. Not for use in diagnostic procedures.
07414692990 ➀ 1014