LP SolidStart I-JoistsLP SolidStart I-Joists make true and uniform floors and ceilingspossible for residential and commercial construction. Machinemade for precise, straight lines that stay straight, they are lighter yet stronger kilo for kilo than traditional timber joists and less likely to split, shrink, twist, warp or bow. LP SolidStart I-Joists are available in long lengths and deep depths so floors and ceilings can be designed with fewer pieces, saving installation and material costs. Builders are confident that they can offer their customers a product with exceptional performance and dependability, along with the peace of mind that comes with a Lifetime Limited Warranty when using LP SolidStart Engineered Wood Products.
Available in:- LPI 20 and LPI 42 (LPI 18, LPI 32, and LPI 52 Special Ordered)
© 2013 Louisiana-Pacific Corporation. All rights reserved. SFI is a registered trademark of Sustainable Forestry Initiative, Inc. PEFC is a trademark of Programme for the Endorsement of Forest Certification. Louisiana-Pacific and SolidStart are registered trademarks and Build With Us is a trademark of Louisiana-Pacific Corporation. The details, specifications, and conditions described in this document are subject to change without notice. INTL0006 2/13
LP® SolidStart® I-Joist
Tech NoteLP® SolidStart® I-Joist
Why Build With Us?There are a number of reasons to choose LP SolidStart I-Joists:
Quality – Remarkably strong, straight, and consistent.
Peace of Mind – LP SolidStart products are backed by a Lifetime Limited Warranty. For warranty details, please visit LPCorp.com/UK.
Problem Solver – Diversified product line offers solutionsfor residential, commercial and industrial construction.
Design Efficiency – Save time and money by designing withfewer pieces.
Our literature is updated frequently, so please visit LPCorp.com/UK for the most current version of our specifications. Also, contact [email protected] with any additional questions.
Proudly Distributed By:
Conserve. Create. Renew.At LP Building Products, we’re proud to offer integrated buildingsolutions that work together to not only save time and money,but also offer many environmental benefits. We believe that“sustainability” means acting in a way that protects the environment,embraces social responsibilities, and builds economic prosperity todayand for future generations. That is why we set a higher standard byfollowing both PEFC and SFI certified forest management and fibersourcing systems to help ensure that our timber comes fromwell-managed forests.
BV-SFICOC-US09000262PEFC/29-31-102
0679-CPD-0817 EUROCODE 50679-CPD-0816
0679-CPD-08390679-CPD-0840
EUROCODE 5ETA-12/0480
LP® SolidStart® I-Joist
Tech Note
Our literature is updated frequently, so please visit LPCorp.com/UK for the most current version of our specifications. Also, contact [email protected] with any additional questions.
LP® SolidStart® I-Joist0679-CPD-0817 EUROCODE 50679-CPD-0816
0679-CPD-08390679-CPD-0840
EUROCODE 5ETA-12/0480
NOTES: 1) The use of LP SolidStart® I-Joists shall be limited to conditions of Service Class 1 and 2 per EN 1995-1-1 (Eurocode 5). 2) See notes and tables below for applicable design factors (kmod, kdef, M) when designing to EN 1995-1-1.3) Characteristic moment resistances assume lateral bracing of the compression flange at a spacing not exceeding 8 times the flange width. 4) Characteristic shear resistances assume a 38mm diameter round hole in the web (knockouts) at approximately 300mm c/c.5) Deflection calculation shall include flexural rigidity (EI) and shear rigidity (GA).6) The supporting members and connectors must be checked by the designer.7) Bearing resistance with stiffeners (WS) assumes proper installation.
Reference CE Certificate of Conformity NumberSt-Prime Mill: 0679-CPD-0839Larouche Mill: 0679-CPD-0840
Characteristic Resistances and Design Properties
Depth Series
Width
Joist
Flexural Shear
Moment Shear
Bearing Resistance
(mm)
(mm)
Weight
Rigidity Rigidity
Resistance Resistance
45mm END 89mm INTERMEDIATE
(kg/m)
EI GA
(kN.m) (kN)
Bearing (kN) Bearing (kN) (x109 N.mm2) (x106 N)
w/o WS with WS w/o WS with WS
225 LPI 20 63 3.6 446 2.3 7.32 12.07 10.35 11.68 22.74 24.54
LPI 42 89 4.7 747 2.3 14.11 13.08 12.29 13.29 30.05 31.87
240 LPI 20 63 3.8 519 2.5 7.89 12.69 10.36 12.04 23.08 24.94
LPI 42 89 5.0 867 2.5 15.20 13.81 12.51 13.78 30.38 32.50
300 LPI 20 63 4.2 879 3.3 10.22 15.22 10.42 13.53 24.46 26.56
LPI 42 89 5.1 1463 3.3 19.70 16.80 13.41 15.76 31.70 35.08
360 LPI 20 63 4.5 1341 4.1 12.38 17.75 10.48 15.02 25.84 28.18
LPI 42 89 5.5 2221 4.1 23.88 19.79 14.05 17.74 33.02 37.66
400 LPI 20 63 4.8 1709 4.6 13.81 19.43 10.52 16.02 26.76 29.26
LPI 42 89 5.8 2819 4.6 26.63 21.79 14.44 19.05 33.90 39.38
LPI™ 20
63mm
225mm240mm300mm360mm400mm
9.5mm
38mm
LPI™ 42
89mm
225mm240mm300mm360mm400mm
9.5mm
38mm
kmod
Duration of Load Moment Shear Bearing w/o WS Bearing with WS SC 1 SC 2 SC 1 SC 2 SC 1 SC 2 SC 1 SC 2 Permanent 0.60 0.60 0.40 0.30 0.50 0.45 0.60 0.60 Long-Term 0.70 0.70 0.50 0.40 0.60 0.55 0.70 0.70 Medium-Term 0.80 0.80 0.70 0.55 0.75 0.70 0.80 0.80 Short-Term 0.90 0.90 0.90 0.70 0.90 0.80 0.90 0.90 Instantaneous 1.10 1.10 1.10 0.90 1.10 1.00 1.10 1.10
kdef Bending Deformation Shear Deformation SC 1 SC 2 SC 1 SC 2 0.60 0.80 1.50 2.25
M Load Duration LPI Joist Connection Fundamental 1.25 1.30 Accidental 1.00 1.00
Eurocode 5 Partial and Modification Factors