Life Testing of LSM-YSZ Composite SOC Electrodes During Current-Switched Operation
Gareth. A. Hughes, Kyle J. Yakal-Kremski, Scott A. Barnett
Department of Materials Science and Engineering, Northwestern University 60208
Motivation Experimental Setup
Project Scope and Future Work
Microstructural Analysis
Electrochemical Evolution
Conclusions
This work was supported by the Global Climate and Energy Project under award 51922
Thanks to Dr. Dean Miller, Dr. Jon Hiller, and Dr. J. Scott Cronin
0 50 100 150 200 250 300 350
0
0.2
0.4
0.6
0.8
1
1.2
1.4
Time (hours)
Are
a S
pecific
Resis
tance (
cm
2)
LSM-YSZ Symmetric Cell Life Test
(1h Current Cycle - 0.5 A/cm2 at 800°C)
Integration of renewable energy sources with the grid requires systems to store excess energy. Solid oxide cells (SOCs) are a proposed new storage method
Aims of current work: • Develop life-testing methods with combined
microstructural and electrochemical characterization • Observe evolution of common air electrode material
(LSM-YSZ) in cyclic operation
[1] Mawdsley, J. R., et al. (2009). "Post-test evaluation of oxygen electrodes from solid oxide electrolysis stacks." International Journal of Hydrogen Energy 34(9): 4198-4207.
Long term durability is unclear: • Oxygen electrode delamination observed
during electrolysis operation • Effects of cycling not known
~ 10 μm LSM Current Collector
~ 20 μm LSM – YSZ Air-Electrode
~ 1 mm YSZ Electrolyte
~ 20 μm LSM – YSZ Air-Electrode
~ 10 μm LSM Current Collector
• Porous composite (La0.8Sr0.2)0.98MnO4-Y0.16Zr0.84O3-δ (LSM-YSZ) electrodes tested at 800 C.
• Symmetrical cells (same LSM-YSZ on both sides) used to isolate air electrode.
• Applied current direction switched every 30 minutes.
• Cells just reach steady state before current direction reversed.
• New test setup developed to avoid contamination by silver current collector grid due to long testing times (up to 1000 h).
• Multiple cells can be tested simultaneously in series using multiple leads.
• SOC operates similar to a flow battery • Electrolysis mode to charge • Fuel cell mode to discharge
System Configuration
Fuel Electrode
Oxygen Electrode
Electrolyte
Feedstock
Storage
Fuel
Storage
Oxygen
Storage
Renewable
Energy Source
Power
Out
e-
e-
e-
e-
O2-
Air
H2O CO2
CO H2 CH4
O2 or
out
• Max theoretical round-trip efficiency: = QFCVFC/QELVEL = VFC/VEL
• η > 80% possible for SOC at J= 0.5 Acm-2
However, this neglects the endothermic process during electrolysis mode.
• VEL > VTN needed to maintain stack temperature
VTN = thermoneutral voltage = H/zF
• Typical cell reaction (800°C): H2O H2 + (1/2)O2,
H= 248.3 kJ mole-1, VTN = 1.29 V Efficiency values are prohibitively low! • 66 % for H2O (VFC = 0.85V) • Other losses further decrease η
Utilize CH4-forming reactions to reduce VEL and increase η
FIB milling with serial imaging Zeiss Nvision 40 FIB/SEM Argonne National Laboratory, EMC
Elec
tro
lyte
LSM YSZ Ag
Furnace
Hot Zone
Pressure
Vessel
Quartz
Tube
Gas Flow and
Electrical
Systems
Cell Mount
Location
• Pressurized testing setup under development.
• Experimentally verify thermodynamic predictions.
• Combine with life testing to develop long-term energy storage solution
RΩ
RP
SOC electrochemical performance is measured by electrochemical impedance spectroscopy.
Results consist of two distinct parts:
• Polarization resistance (RP) – a measure of electrode processes such as charge transfer and gas diffusion.
• Ohmic resistance (RΩ) – a measure of electrolyte resistance.
102 Hz 103 Hz
104 Hz
105 Hz
Sets of symmetric cells tested at 1.5A/cm2 and 0.5A/cm2
• Higher current density displayed a significant increase in both RP and
RΩ.
• Largest change seen in RΩ, indicating potential electrolyte issues.
• Lower current density showed no significant change whatsoever.
Degradation rate depends on
current density
Degradation and Current Density
SEM analysis did not show any physical difference between tested and untested electrode structures.
• Delamination not observed.
• Resolution may not be sufficient to observe initial stages of delamination.
More detailed microstructural analysis will be completed using 3D FIB-SEM reconstruction method.
Tested at 1.5A/cm2 Untested Structure
Cathode Functional Layer Phase Segmentation
5 μm
• Current-switching testing method has been used to observe the performance of LSM-YSZ reversible electrodes.
• EIS used to track performance of LSM-YSZ over 1000 h of current cycling.
• Degradation occurred only at high current density while performance at low current remained constant.
• Microstructural changes were not observed via traditional SEM microscopy.
• Further analysis is underway using 3D FIB-SEM reconstruction to analyze wider-range and 3D-specific structure features.
• Results will help to develop a reversible SOC system for energy storage.
0 200 400 600 800 1000
0
0.2
0.4
0.6
0.8
1
1.2
1.4
Time (hours)
Are
a S
pecific
Resis
tance (
cm
2)
LSM-YSZ Symmetric Cell Life Test
(1h Current Cycle - 1.5 A/cm2 at 800°C)
Rt
R
RP