+ All Categories
Transcript
Page 1: MarConnect. USB ready - Willrichwillrich.com/wp-content/uploads/2014/11/Mahr-Federal-Marconnect-Wireless.pdf11-9 4102715 / 70246 4 4102 57 4102410 4102411 4 4602 4 46020 2001025

-

11-2

� � � � �

�������������

• Easily extendablewith additionalUSBhubs

• Multiple measuring station iseasilysetupwithaUSBhub,

upto100measuringdevicescanbesimultaneously

connected

• Clear and flexible data acquisitionwiththeeasytouseMarComProfessionalSoftware

• CompatiblewithallMarConnect USBreadymeasuringinstruments

MarConnect. USBreadyThe new f l ex ib le MarConnect i n te r face f rom

Mahr. S imp l i f i es bo th da ta t ransmi s s ion to a PC

and enab les qu i ck and un i ve r sa l a s semb ly o f a

mu l t ip l e measu r ing s ta t ion .

• Choose alternative methods of data transmissioneitherwithafootswitchoraPCkeyboard,directonthemeasuringinstrumentorwiththeTimerfunction

MarConnect. DataProcessing

GEORGE
Typewritten text
Willrich Precision Ph 866-945-5742 email: [email protected]
Page 2: MarConnect. USB ready - Willrichwillrich.com/wp-content/uploads/2014/11/Mahr-Federal-Marconnect-Wireless.pdf11-9 4102715 / 70246 4 4102 57 4102410 4102411 4 4602 4 46020 2001025

+

11-�

MarCom Software

IBMATcompatiblePCMSWindows®2000,XP,VistaUSBinterface,higherthan1.1upto10MBCD/DVDdriveRecommended:MSExcelfromVersion97onwards Order no.

Software MarCom Professional 4102552Software MarCom Standard 4102551

System Requirements

Software MarCom Professional •Measuredvaluescanbe

directlytransferredintoeitherMSExcel(fromversion97)orintoatextfileorkeycode

•Themeasuredvaluesfromeachinstrumentcanbesenttoadifferentcolumn,tableorfolderinExcel

•Datatransmissionispossiblevia.USBand2serialCOMinterfaces

•USBhubisalsosuitableasameasuringinstrumentinterface

•Upto100measuringinstrumentscanbeconnectedwithUSBdatacable

•Clearportrayalofthechosenmeasuringinstrmentswiththeaidoficons

•SeveralfootswitchescanbeconnectedupviaUSB.Measuringinstrumentscanbefreelyassigned

•Freelydefinableandconfigurablemeasurementcycles

•Thereareavarietyofwaystotransmitdata,youcaneitherpressthe“Data“buttononthemeasuringinstrumentoronthedatacable;viaacomputer,timer,keyboard;orbyactivatingafootswitchconnectedtoaUSBinterface

•Textfilecanbeeditedthustranslatedindiverselanguages

Software MarCom Standard(USBcableisnotincludedinthescopeofsupply)

FeaturesandsystemrequirementsareidenticaltoMarComProfessional,exceptthatitonlyhasoneUSBandoneserialCOMinterface

Features

MarConnect. DataProcessing

Page 3: MarConnect. USB ready - Willrichwillrich.com/wp-content/uploads/2014/11/Mahr-Federal-Marconnect-Wireless.pdf11-9 4102715 / 70246 4 4102 57 4102410 4102411 4 4602 4 46020 2001025

-

11-4

�������

��������������

� � � � ����������

����

DataConnectionCable16 EXuOrder no. 4102�57incl.MarComStandard

forMarCal.Calipers16EX/EXP16EXV18EX/EXP30EX/EXN

forDigimar.HeightGages814S

forMicromar.Micrometers40EX,40EWS,40EWV44EX,46EX

DataConnectionCable2000 usbOrder no. 4�4602�incl.MarComStandard

forMarCator.Dig.Indicators1088

DataConnectionCableMC-IOrder no. 4102782incl.MarComStandard

forFoot switchOrder no. 4102058

USB-HUB7-foldindustrialmodel220 V Order no. 410255�110 V (US type) Order no. 2245786

USB readyMeasuringInstruments

forMarCator.Dig.Indicators1075,1080,1081,1086,1087

forMillimess.DigitalComparators200020012100

MarConnect. DataProcessing

Page 4: MarConnect. USB ready - Willrichwillrich.com/wp-content/uploads/2014/11/Mahr-Federal-Marconnect-Wireless.pdf11-9 4102715 / 70246 4 4102 57 4102410 4102411 4 4602 4 46020 2001025

+

11-7

Send confirmation

Sendmeasuring value

DATA-Button

Confirmation,acoustic

Confirmation, optical

-OK

-Transmissionerror

Transmitter

������

MarConnect. DataProcessing

Radio Transmission RadiosystemFM1*

•Securedatatransmissionwithdialoguebetweenreceiverandtransmitter

•Acousticandopticalconfirmationofreceiptbythetransmitter

•Compacttransmitterisconnecteddirectlyontheinterfaceofthemeasuringinstrument

Features

For Measuring Instruments Order no.

MarCal 16EX,16EXC,16EXV, 16 EXt 4102�21 18EX,30EX,30EXNDigimar 814SMicromar 40EX,44EX,46EX,40EWS,40EWVMarCator 1075,1080,1081,1086,1087

MarCal 25ES,30EWD,31ES,32ES 16 ESt 4102�22Digimar 27ES,M814MarTool 106ES

Millimar C1208,C1216,C1245,S1840 RS2�2 t 2121�15Digimar CX1,CX2,817CLM

ContactMahrFederalfortransmitterstobeusedwith: µMaxµm Digimaticdevices Digimaticdatacables

Transmitter

Order no.

ReceiverforUSB FM 1 4102�20interfacesincl.driverandbasicsoftware.BasicsoftwareconsistsofasoftwarekeyboardinterfaceandsoftwaretostoremeasuredvaluesinanMS-Excel®column.

Receiver

Order no.

Mahr_EXDLL(optional) 4102�2�SoftwareforstoringmeasuringdataofseveralradiomodulesinanyExceltable.ContactMahrFederalforoptionalMSExcelbasedsoftwarethatallowfor:• Datamanipulationofupto120datainputs• FullSPCandgraphicaldisplays

Optional Software

•PowerissuppliedforthereceiverviaaUSB-InterfaceonthePC

•Upto120measuringinstrumentscanbeconnectedtothereceiver

•Radiotransmissiondistanceisfrom10mupto200m

(dependingontheenvironment)

•Radiofrequencyis433.926MHz

ThetransmissionofthemeasuredvaluetakesplaceviaactuationoftheDATAbuttononthetransmitter.Thetransmittersupplementsthemeasuredvaluewithanaddressnumber,acommunicationcontrolwordandadoublechecksum.ThespecialdatacodingandthefeedbackfromthePCtothetransmitterensuresabsolutedatasecurity.AtransmissionerrorisrecognizedbythedialoguebetweenPCandtransmitter.ThedatatransmissionisthenrepeateduptothreetimesautomaticallywithinafewmillisecondsWhenthedataissuccessfullytransmittedthegreenlightonthetransmitterflashesandashortbeepisheardconfirmingtransmission.

* Only available in North America, Canada and Mexico

Page 5: MarConnect. USB ready - Willrichwillrich.com/wp-content/uploads/2014/11/Mahr-Federal-Marconnect-Wireless.pdf11-9 4102715 / 70246 4 4102 57 4102410 4102411 4 4602 4 46020 2001025

-

11-8

DigimaticRS232C������

MarConnect. InterfacesOverview

① OnlyavailableinNorthAmerica,CanadaandMexico② Footswitch;onlywithanadditionalUSBPort③ Cablelength18cm/7”

④ Datatransmissiononlywiththe“Data“keyor“automatic transmisison“onthemeasuringinstrument⑤ Footswitchtotransferdataonthemeasuringinstrument Millimar-Orderno.5330956/Millimar1240-Orderno.5312431

Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via

Instrument MarCom Software MarCom Software USB

FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058

16EX/EXC

16EXV

18EX

30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411

40EX,40EWS,40EWV,

46EX,44EX

1075,1080,1081,1086,1087

814S

2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021

1088

838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥

MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035

µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025

25ES

30EWD

31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510

106ES

M814

MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------

1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634

C1208,C1216

DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④

MarConnect. DataProcessing

--------

Page 6: MarConnect. USB ready - Willrichwillrich.com/wp-content/uploads/2014/11/Mahr-Federal-Marconnect-Wireless.pdf11-9 4102715 / 70246 4 4102 57 4102410 4102411 4 4602 4 46020 2001025

+

11-9

4102715 / 70246�4

41024104102�57 4102411

4�4602� 4�46020

2001025 / 22�90�7 / 4495084 ⑥

4102510

4�46021

4102��0 to 4102��4 ⑥

4102058

4102711

4102782 ③

MarConnect . Regard lessof which inter facestandardyouuse , whether ; U SB , OptoR S232oderDig imat ic , MarConnect a lwaysprov idesyouwith theopt imumconnect ion .

Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via

Instrument MarCom Software MarCom Software USB

FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058

16EX/EXC

16EXV

18EX

30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411

40EX,40EWS,40EWV,

46EX,44EX

1075,1080,1081,1086,1087

814S

2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021

1088

838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥

MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035

µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025

25ES

30EWD

31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510

106ES

M814

MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------

1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634

C1208,C1216

DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④

⑥ Cablelength1.5m/5ft⑦ NotforMillimar1240

Standardcablelength2m

MarConnect. DataProcessing

--------