1
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
© 2017 BAKER HUGHES INCORPORATED. ALL RIGHTS RESERVED. TERMS AND CONDITIONS OF USE: BY ACCEPTING THIS DOCUMENT, THE RECIPIENT AGREES THAT THE DOCUMENT TOGETHER WITH ALL INFORMATION INCLUDED THEREIN IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF BAKER HUGHES INCORPORATED AND INCLUDES VALUABLE TRADE SECRETS AND/OR PROPRIETARY INF ORMATION OF BAKER HUGHES (COLLECTIVELY " INFORMATION"). BAKER HUGHES RETAINS ALL RIGHTS UNDER COPYRIGHT LAWS AND TRADE SECRET LAWS OF THE UNITED STATES OF AMERICA AND OTHER COUNTRIES. THE RECIPIENT FURTHER AGREES THAT THE DOCUMENT MAY NOT BE DISTRIBUTED, TRANSMITTED, COPIED OR REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, ELECTRONIC, MECHANICAL, OR OTHERWISE, WITHOUT THE EXPRESS PRIOR WRITTEN CONSENT OF BAKER HUGHES, AND MAY N OT BE USED DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL TO BAKER HUGHES’ INTEREST.
Mihai Marcu Global Business Development Manager Multilaterals
2
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
EVOLUTION OF MULTILATERALS FOR UNCONVENTIONAL RESERVOIRS
• OPERATORS’ INTEREST IN MULTILATERAL TECHNOLOGY INCREASED SIGNIFICANTLY DURING
CURRENT INDUSTRY DOWNTURN
• INDUSTRY IS ACTIVELY SEARCHING FOR WAYS TO PRODUCE CONVENTIONAL AND
UNCONVENTIONAL RESOURCES MORE ECONOMICALLY
• SERVICE COMPANIES WITH STRONG R&D DEPARTMENTS AND DIVERSIFIED MULTILATERAL
PRODUCT PORTFOLIO ARE BEST POSITIONED TO BENEFIT FROM CURRENT ECONOMIC
ENVIRONMENT
3
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
MARKET DRIVERS FOR MULTILATERAL COMPLETIONS
• OPTIMIZE RESERVOIR EXPLOITATION
• REDUCE CAPITAL INVESTMENT
• IMPROVE OPERATIONAL EFFICIENCY
4
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
OPTIMIZE RESERVOIR EXPLOITATION
• INCREASE RESERVOIR INTERFACE
• INCREASE RESERVE BASE PER WELL
• INCREASE FIELD PRODUCTION WITH FEWER WELLS
• MAINTAIN WELL PRODUCTION & EXTEND LIFE CYCLE
• MORE EFECTIVE RESERVOIR MANAGEMENT
• FIELD REJUVENATION
MARKET DRIVERS FOR MULTILATERAL COMPLETIONS
5
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
MARKET DRIVERS FOR MULTILATERAL COMPLETIONS
REDUCE CAPITAL INVESTMENT
• SURFACE LOCATION
• CASING & CEMENTING
• WELLHEAD EQUIPMENT
• PIPE LINE
• PRODUCTION FACILITIES
• ENVIRONMENTAL IMPACT
6
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
MARKET DRIVERS FOR MULTILATERAL COMPLETIONS
IMPROVE OPERATIONAL EFFICIENCY
• REDUCE RIG MOBILIZATION / DEMOBILIZATION COSTS
• INCREASE NUMBER OF LATERALS
• REDUCE NUMBER OF TRIPS
• INCREASE FUNCTIONALITY
• RIGLESS OPERATIONS
• RISK MITIGATION
7
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
© 2017 BAKER HUGHES INCORPORATED. ALL RIGHTS RESERVED. TERMS AND CONDITIONS OF USE: BY ACCEPTING THIS DOCUMENT, THE RECIPIENT AGREES THAT THE DOCUMENT TOGETHER WITH ALL INFORMATION INCLUDED THEREIN IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF BAKER HUGHES INCORPORATED AND INCLUDES VALUABLE TRADE SECRETS AND/OR PROPRIETARY INF ORMATION OF BAKER HUGHES (COLLECTIVELY " INFORMATION"). BAKER HUGHES RETAINS ALL RIGHTS UNDER COPYRIGHT LAWS AND TRADE SECRET LAWS OF THE UNITED STATES OF AMERICA AND OTHER COUNTRIES. THE RECIPIENT FURTHER AGREES THAT THE DOCUMENT MAY NOT BE DISTRIBUTED, TRANSMITTED, COPIED OR REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, ELECTRONIC, MECHANICAL, OR OTHERWISE, WITHOUT THE EXPRESS PRIOR WRITTEN CONSENT OF BAKER HUGHES, AND MAY N OT BE USED DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL TO BAKER HUGHES’ INTEREST.
8
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
MULTILATERAL COMPLETIONS – EMERGING PRODUCTS
• TWO MAIN COMPONENTS:
• MODEL C HOOKTM HANGER
• BoreHunter ASSEMBLY
• VIRTUALLY UNLIMITED NUMBER OF TAML LEVEL 4 JUNCTIONS CAN BE INSTALLED IN SAME SIZE CASING
• SELECTIVE ACCESS TO EACH LATERAL USING TIEBACK STRING
• PRESSURE ISOLATION DURING FRACTURING
• BACK-TO-BACK FRACTURING OF MULTIPLE LATERALS IN A SINGLE TRIP
• LARGE BoreHunter ID ALLOWS FOR POST-FRAC OPERATIONS THROUGH THE FRAC STRING (e.g. FRAC
PLUGS DRILL-OUT & FLOWBACK)
• SELECTIVE RE-ENTRY WITH PRESSURE ISOLATION FOR RE-FRACTURING AND WELL INTERVENTION
BoreHunter SELECTIVE RE-ENTRY SYSTEM
BoreHunter Assembly
Model C HOOK Hanger
9
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
• TAML LEVEL 3 OR LEVEL 4 MULTILATERAL JUNCTION THAT PROVIDES MECHANICAL SUPPORT
AND RE-ENTRY CAPABILITY TO ALL LATERALS
• LOCATES INTO A CASING EXIT WINDOW
• INSTALLATION IS SIMILAR TO A CONVENTIONAL LINER
• MULTIPLE COMPLETION OPTIONS FOR THE LATERALS
HOOK Hanger Lateral Liner
Main Bore Casing
HOOKTM HANGER
HOOK Hanger
10
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
• RUN ON THE BOTTOM OF THE FRAC STRING
• HYDRAULIC-ACTIVATED ADJUSTABLE CONE PROVIDES SELECTIVE RE-ENTRY CAPABILITY TO ALL LATERALS
• BULLET SEALS PROVIDE PRESSURE ISOLATION DURING FRACTURING
• BACK-TO-BACK FRACTURING OF MULTIPLE LATERALS IN A SINGLE TRIP
• LARGE BoreHunter ID ALLOWS FOR POST-FRAC OPERATIONS THROUGH THE FRAC STRING (e.g. FRAC PLUGS
DRILL-OUT & FLOWBACK)
BoreHunter ASSEMBLY
BoreHunter Assembly
Bullet Seals
Adjustable Cone
11
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
BoreHunter Assembly
Model C HOOK Hanger
Model C HOOK Hanger
Model C HOOK Hanger
Frac String
MULTILATERAL COMPLETION WITH MODEL C HOOK HANGER AND
BoreHunter SELECTIVE RE-ENTRY SYSTEM
12
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
© 2017 BAKER HUGHES INCORPORATED. ALL RIGHTS RESERVED. TERMS AND CONDITIONS OF USE: BY ACCEPTING THIS DOCUMENT, THE RECIPIENT AGREES THAT THE DOCUMENT TOGETHER WITH ALL INFORMATION INCLUDED THEREIN IS THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF BAKER HUGHES INCORPORATED AND INCLUDES VALUABLE TRADE SECRETS AND/OR PROPRIETARY INF ORMATION OF BAKER HUGHES (COLLECTIVELY " INFORMATION"). BAKER HUGHES RETAINS ALL RIGHTS UNDER COPYRIGHT LAWS AND TRADE SECRET LAWS OF THE UNITED STATES OF AMERICA AND OTHER COUNTRIES. THE RECIPIENT FURTHER AGREES THAT THE DOCUMENT MAY NOT BE DISTRIBUTED, TRANSMITTED, COPIED OR REPRODUCED IN WHOLE OR IN PART BY ANY MEANS, ELECTRONIC, MECHANICAL, OR OTHERWISE, WITHOUT THE EXPRESS PRIOR WRITTEN CONSENT OF BAKER HUGHES, AND MAY N OT BE USED DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL TO BAKER HUGHES’ INTEREST.
13
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
• TAML LEVEL 5 HYDRAULICALLY ISOLATED JUNCTION
• ABILITY FOR COMINGLED OR SEPARATE FLOW
• 5,000 PSI PRESSURE RATING
• POSITIVE MAIN BORE AND LATERAL RE-ENTRY
• SUITABLE TO NEW OR RE-ENTRY WELLS
HydraSplit System
Lateral Leg
Main Bore Leg
14
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
9 7/8" Casing w/recess shoe
Luna Dual Gauge
Tubing Hanger
7" Production Tubing
8" Expanded linerExpanded to 8.6" ID
7" ONYX-7.5 Safety Valve10 3/4"x 7" AVLDM Annular SafetyValve
5 1/2" SPM w/ Dummy
9 7/8"x5 1/2" PremierPacker w/ feed through
9-5/8" x 7" MLZXLiner Hanger andPacker w/ PBR
5 1/2" HCM-A
9-5/8" x 7" ZXPLiner Hanger andPacker w/ PBR
3 1/2" Shrouded HCM-A
5 1/2" Perforated liner
Seal Bore diverterassembly
Tension LockSwivel
5 1/2" Removablebridge plug
Size 7x5x5xForm 5Junction w/5 1/2" Pinlateral connectionand 5 1/4" main boreseal stinger
Model MLHRproductionanchor w/PBRseal assembly
8 1/2" open holew/5 1/2" Perforated liner
10 3/4"x 6 5/8" FLX-4 Pack off Tubing Hanger
7" Punch Nipple
4 1/4" Seal Bore Sub
15
© 20
17 B
aker
Hug
hes I
ncor
pora
ted. A
ll Righ
ts Re
serve
d.
THANK YOU!