ContentsDesigner and manufacturer of vacuum systems forIndustry 2
.Lubricated rotary vane vacuum pumps.ROTOMIL'S C4 - C8 4EVISA 6
.Accessories for vacuum.Sealed suction filters 12Dust separator 14Inlet vacuum precleaner filter 15Liquids traps for vacuum pumps 16"SPIREACIER" special hoses for vacuum 17Air cooler 17Vacuum solenoid valves 18Vertical vacuum receivers 20Electronic controller for vacuum 21Vacuum switches and vacuum gauges 22
.ATEX lubricated rotary vane vacuum pumps.ATEX area defining 23EVISA ATEX version 24
.Oil-free rotary vane vacuum pumps.ARICA 3VK to 60V 26
.Claw vacuum pumps.SIRELLA 30
.Oil-free screw vacuum pumps.EVOLIS 32
.Oil-free piston vacuum pumps.PS 34
.Side channel vacuum pumps.KAV 36
.Rotary lobe vacuum pumps ROOTS type.RV5 and RV8 38
.Rotary piston vacuum pumps ROOTS type.BOOSTER 48
.ROOTS / vacuum pumps assembly.BOOSTER / EVISA 50
.Liquid ring vacuum pumps.ANTIGUA 52
.Automatic vacuum plants.MINIVAC 1 54INDUSVAC 1 56
INDUSVAC 2 58INDUSVAC 1 and 2 ATEX 60
.Automatic vacuum plants for composites.Static and mobile COMPOSITVAC 62
.Automatic vacuum chambers.Vacuum or mixer casting machine 64MODELVAC 65Degassing vacuum chambers 66
.Vacuum plants for lubricant extraction.Static and mobile VIDANGEMIL'S 68
.Vacuum plants for fluid transfer.Static and mobile RECUPMIL'S 70RECUPCARBU / PLASTICARBU 72Fuel pumping and refilling centralized system 73
.Siphon vacuum priming device.Priming water pumps 75
.Vacuum plants for laboratories.LABOVAC 1 76LABOVAC 2 78CRYOLIS 80
.Oil-free rotary vane blowers.ARICA 3PK to 60P 83
.Claw blowers.SIRELLA 86
.Side channel blowers.KAV 88
.Tri-lobe blowers.ROOTS RS 90
.Pressure measurement and control.Manometers 96
.Control and regulation.Direct starters and frequency converters 97Control and regulation devices 98
.MIL'S : Services.Services 100Dimensioning calculation and conversion tables 101General sales and guarantee conditions 102
2
Our company
MIL'S, French vacuum pumpsmanufacturer, was founded in 1926and currently employs 90 people ontwo sites in the outskirts of Lyonand one sales office in the outskirtsof Paris.The company operates over 10 000sq.m of manufacturing floor space.From design, through to sale, ourunderstanding and control of theprocesses involved enables us tooffer a high quality product, using :
• State-of-the-art computerassisted design software
• NC-plant and equipmentand several assembly facilities
• Product packaging techniquesdevised in-house
• A dynamic, solutions-orientedsales force
• Field service engineersand maintenance contractsfor your plant and equipment
• Our customer trainingcentre to transfer in depthknowledge of our productsand their uses.
handling
Entrance hall
Main office
Machining
Design office
Check room
Testing room
3
Our products
MIL'S products cover a wide rangeof applications from vacuumpumps and compressors through tofully integrated and sophisticatedsystems for :
• packaging,• mechanical handling,• plastics engineering,• agri-food technology,• environment protection.
Whether the project is standard orspecial, MIL'S is able to meet thespecifications of all its French andinternational clients.
Designer and manufacturerof vacuum systems for Industry
compaction
Centralizedvacuum system
3 X E600
Blue Harboursystem
Mobile Blue Harbour
Degassing vacuumchamber
extractiondrying
degassing
packaging
Vacuum chamber
4
ROTOMIL’S C4 - C8
Specifications are subject to be changed without notice
C8 - 03C4 - 03
Capacity - pressure curve (50 Hz)
Flow rate (m3/h)
Absolute pressure (mbar)
Characteristics
16
10
6
4
2
1
0,6
0,4
0,2
0,11 2 3 5 10 25 50 100 500 1013
1013
500
100
10
32
10 10 20 30 40 50 60
1Suction filter withpaper, polyester or
activated carboncartridges
2Suction hoses
3Adjusting valve
fitted on T-square
Accessories
Average evacuation time (50 Hz)
NOMINAL END POWER ROTATION NOISE OIL WEIGHTCAPACITY VACUUM SPEED LEVEL FILLINGm3.h-1 mbar kW rpm dB(A) L kg
50 HZ 60 HZ 50 HZ 60 HZ 50 HZ 60 HZ�C4 - 03 4,0 4,8 3 0,15 0,18 1450 1740 60 0,20 9,5�C8 - 03 8,0 9,6 3 0,25 0,30 2800 3360 65 0,20 10
Time (min.)
Abso
lute
pres
sure
(mba
r)
100 l receiver
Lubricated rotary vane vacuum pumps
Specifications are subject to be changed without notice
VACU
UM
pumps
5
• Integrated gas ballast• Running and maintenance low costs• Compact construction and low noise• Small dimensions and weight for high performance
Rotomil’s C4 - C8
Dimensions
EXHAUSTG1/8”
SUCTIONG1/4” Oil filling
Pump references
Accessory and option references
* Use in the end vacuum range from 100 to 3 mbar • ** PA : paper, PO : polyester
Rotomil’s � C4 - 03* � C8 - 03*
with oil filling 1-ph 230V 818955 817882
� C4 - 03* � C8 - 03*
Fitted suction filter**1 25PA : 35822525PO : 362241
Base frame assembly 670019
Fitted suction hose2 670177
Fitted adjusting valve3 703020Fitted adjusting valve and vacuum gauge 670069Direct starters without control panel 1ph 230V 770502
with LG7 control board 1ph 230V 710427
6
Lubricated rotary vane vacuum pumps, reliable androbust designed for low or medium vacuum.
EVISA
Specifications are subject to be changed without notice
Abso
lute
pres
sure
mba
rFl
owra
te(
m3 .h
-1)
Capacity - pressure curve without gas ballast (50 Hz)
NOMINALCAPACITYm3.h-1
PNEUROPCAPACITYm3.h-1
END VACUUMmbar Pwo
mbar
Cwo
kg.h-1
MOTORPOWERkw
ROTATIONSPEEDrpm
NOISELEVELdB (A)
OILFILLING
L
WEIGHT
kgwithoutgas ballast
withgas ballast
50 Hz 60 Hz 50 Hz 60 Hz HV HV MV 50 Hz 60 Hz 50 Hz 60 Hz�E17 17 20 16 19 0,5 1,5 3 39 0,29 0,55 0,66 1000 1200 59 1,5 34
�E25 30 36 28 33 0,5 1,5 3 41 0,46 0,75 0,9 1450 1740 60 1,5 35
�E40 47 56 41 49 0,5 1,5 3 42 0,9 1,1 1,3 1450 1740 62 1,5 45
�E65.2 65 78 63 75 0,1 1,2 3 39 1,8 1,5 1,8 1450 1740 65 4 70
�E100.2 96 115 94 112 0,1 1,2 3 50 3,2 2,2 2,64 1450 1740 67 4 80
�E150 150 180 147 176 0,1 1,2 3 50 3,6 3 3,6 1450 1740 70 7 102
�E200 190 228 185 222 0,1 1,2 3 48 4,5 4 4,8 1450 1740 71 7 115
�E300 288 345 263 315 0,1 1,2 3 50 7 5,5 6,6 1450 1740 73 7 190
�E350 360 432 341 409 0,1 1,2 3 40 9 7,5 9 967 1160 74 10 350
�E400 426 511 410 492 0,1 1,2 3 42 11 9 10,8 967 1160 74 10 380
�E500 513 616 496 595 0,1 1,2 3 46 14 11 13,2 967 1160 74 10 420
�E600 632 758 597 716 0,1 1,2 3 52 17 15 18 967 1160 75 10 450Pwo : Maximum admissible of water vapour pressure
Cwo : Pumping capacity of water vapour
1000
100
10
10 1 2 3 4 5 6 7 8 9 10 12 14 16 18
1000 lreceiver
E17E25E40E65.2E100.2E150
E200E300E350E400E500E600
E600E500E400E350E300E200E150E100.2
E65.2
E40
E25
E17
0,1 0,5 10,1
2 3 4 5 6 7 98 10-1
20 30 40 60 80100-10
200 300400 600 800 1013 mbar-100 kPa
700600500
400
300
200
1009080706050
40
30
20
10987654
3
2
1
0,1 0,5 1 2 3 4 5 6 7 98 10 20 30 40 60 80100 200 300400 600 800 1013 mbar
1000
800
600
400
200
150
100
5040302010
0 5 10 15 20 30 40 50 60 70 80 90 100 110 120 130 150 165 180 200
Abso
lute
pres
sure
mba
r
Time (s)
Time (min.)
Absolute pressure
1000 l receiver
Average evacuation time (50 Hz)
HV type : High vacuumMV type : Medium vacuum
10
Specifications are subject to be changed without notice
EVISA
8Polyester/carbondouble filtration
7Reversed paper
double filtration
15Electrovalves
and valves
14Vertical vacuum
receiver
16Air cooler
11Cyclonic
liquid trap
10Dust separator
with removablebag
12Butterfly valve
13Liquids trap
protecting vacuumpumps against
liquids
9Cyclonic inlet
vacuum precleanerfilter
Direct starter without control panel 3-ph 400V3-ph 230V1-ph 230V
with LG7 start and stop system 3-ph 400V3-ph 230V1-ph 230V
Star/delta starter 400V+N+Ewith : 1 electric atmospheric pressure valve (230V-50 Hz)or 1 pneumatic atmospheric pressure valve (6 bar)
Double suction filter7 Reversed paper filtration
Double filtration aspiration8 Polyester / carbon
Cyclonic inlet vacuum precleaner filter9 see page 15
Dust separator with removable bag10 see page 14
Cyclonic liquid trap11 see page 14Additional oil exhaust filterButterfly cast iron valve DN80 with electric actuator230V - 50 Hz - opening time : 20 seconds with integrated delayingDouble acting pneumatic butterfly cast iron valve DN 80with electric actuator 5/2 NF - 230V - 50 Hz
12
Frequency converter 3-ph 400V - 50 HzPNEUROP inlet flange
Vacuum liquids traps13 see page 16
Vertical vacuum receiver14 see page 20
Electrovalves and valves15 see page 18
Air cooler16 see page 17
Accessory and option references (continued)
The carbon filter has to be combined with paper or polyester downstream to avoid carbonmigration in the pump
VACU
UM
pumps
11
Specifications are subject to be changed without notice
Accessories
�E17 �E25 �E40 �E65.2 �E100.2 �E150 �E200 �E300 �E350 �E400 �E500 �E600770495 770496 770497 770498 770499 770500 770501 719237 719238770496 770497 770498 770499 770500
770503 770504710422 710423 710424 710425 710426 713746 719239710430 710431 710432 710433 710434
710428 710435718389 718390 718391 718392
617496618257
2 x 76 PA : 670613 2 x 126 PA : 670614 2 x 201 PA : 67061576 PO + 76 CH
670616126 PO + 126 CH
670617201 PO + 201 CH
670618
High steel model : 616113 Stain-less steel model : 619058618259 618260 618261
617522
617523
361617 361618 361619 361620 361621 361622 361623 361624 361625117133 (25KF) 117134 (40KF) 117132 (50KF) 117130 (80 ISO K)
Special oils for vacuum pumps100% synthetic oil for continuous running
Synthetic oil 1 litre can 2 litre can 5 litre can 20 kg jerry can 47 kg small cask 170 kg caskMV46S 670291 356932 356941 357077 357748 357450MV99S 362660 362661 362662
Food industry – FDA agreement : for risk of accidental food contactsAGRO 46 food quality oil
Oil 20 litresOXYVAC 100 360881
Food industry oil 1 litre 2 litres 5 litres 20 litresAGRO 46 616073 616074 616075 361019
Specific oil : for high oxygen pumping process
12
Vacuum sealed suction filters
Specifications are subject to be changed without notice
CG
D
F
1/4"
1/4"
B
AE
C
A
D
E
C
AB
F
D
GOptional flange
OUTLETINLET INLET
25 to 51 filters
OUTLET
OUTLET(male)
INLET(female)
INLE
T
OUTLET
CL300 to CL600right-angle filters
CT201 to CT601straight-through filters
for M14 thread
76 to 251filters
Characteristics and dimensions
• One or two 1/4” differential taps for gauges (further to model)• Element removal efficiency : 99% at 2 micron (paper element) and at 5 micron (polyester element)• Rugged construction• Vacuum level : 1,3 x 10-3 mbar• Running temperature (continuous) : min –25°C and max +100°C• Low pressure drop
A’ A
C’CF1/4”
GE D
B
Right-angle filters
Straight-through filters
Inlet Dimensions expressed in mm Filter Filter WeightRIGHT-ANGLE filters Outlet A B C D E F G flow element flow
DN mm m3.h-1 m3.h-1 kg76 PA/PO/CH G3/4” - G3/4” 97 14 149 67 80 127 83 43 94 1100 PA/PO/CH G1” - G1” 92 19 149 67 80 60 94 1126 PA/PO/CH G1”1/4 - G1”1/4 154 19 185 120 105 173 133 102 196 2201 PA/PO/CH G2” - G2” 236 19 222 125 112 194 235 298 493 7251 PA/PO/CH G2”1/2 - G2”1/2 235 32 222 140 129 357 493 7CL300 PA/PO DN80 PN10/16 689 76 356 470 76 305 381 551 969 28CL400 PA/PO DN100 PN10/16 689 76 356 470 76 305 381 884 969 28CL500 PA/PO DN125 PN10/16 714 76 470 495 76 406 381 1360 1496 40CL600 PA/PO DN150 PN10/16 740 102 470 521 102 406 381 1870 1870 50
STRAIGHT-THROUGH filters
InletOutlet
Dimensions expressed in mm Filterflowm3.h-1
Filterelement flow
m3.h-1
Weight
kgA A’ B C C’ D E F G25 PA/PO G1/4” 83 62 11 7 14 0,5038 PA/PO G3/8” 83 62 11 10 14 0,5051 PA/PO/CH G1/2” 105,5 81 18 17 20 0,75CT201 PA/PO G2” 330 194 229 276 229 143 457 297 493 7,3CT251 PA/PO G2”1/2 330 194 229 276 229 143 457 357 493 6,8CT301 PA/PO G3” 467 503 251 343 383 403 322 254 635 510 969 14CT401 PA/PO G4” 467 513 251 343 383 403 322 254 635 884 969 14CT501 PA/PO G5” 464 406 483 365 251 375 508 1360 1870 22CT601 PA/PO G6” 464 406 483 365 251 375 508 1870 1870 20
VACU
UM
pumps
13
Accessories
Specifications are subject to be changed without notice
References
RIGHT-ANGLE filters 76… 100… 126… 201… 251… CL 300… CL 400… CL 500… CL 600…Filter paper PA 76PA 100PA 126PA 201PA 251PA CL 300PA CL 400PA CL 500PA CL 600PA
357893 360595 357894 357895 357896 361626 361050 361311 361312polyester PO 76PO 100PO 126PO 201PO 251PO CL 300PO CL 400PO CL 500PO CL 600PO
357910 362235 362236 362237 362238 362239 361670 362240 361422carbon CH 76CH 100CH 126CH 201CH 251CH
610515 616194 610516 610517 610518Filtering element paper 842 842 848 850 850 234 P 244 P 274 P
357898 357898 357899 357900 357900 357901 361313 361315polyester 843 843 849 851 851 235 P 245 P 275 P
357902 357902 357903 357904 357904 357905 361314 361316carbon 842 AC 842 AC 848 AC 850 AC 850 AC
357906 357906 357907 357908 357908
STRAIGHT-THROUGH filters 25… 38… 51… CT 201… CT 251… CT 301… CT 401… CT 501… CT 601…Filter paper PA 25PA 38PA 51PA CT 201PA CT 251PA CT 301PA CT 401PA CT 501PA CT 601PA
358225 362243 357947 362015 362016 357897 361106 361309 361310polyester PO 25PO 38PO 51PO CT 201PO CT 251PO CT 301PO CT 401PO CT 501PO CT 601PO
362241 362244 357948 362231 362232 362233 362234 362137 361392Filtering element paper 04 06 850 234P 274P
358227 357950 357900 357901 361315polyester 05 07 851 235P 275P
362253 357951 357904 357905 361316
STRAIGHT-THROUGH filters with polycarbonate cylinder ST 201… ST 251… ST 301… ST 401…Filter paper PA ST 201PA ST 251PA ST 301PA ST 401PA
362245 362246 361627 362277
Accessories and options for CT STRAIGHT-THROUGH filters CT 201… CT 251… CT 301… CT 401…Bracket for mural fixing 619907 617512Polycarbonate cylinder kit ST850 ST234P
362248 362250Flanges 617513 617514
Silent suction filters
ØB
C
A
ØB
ØC
A
INLET
OUTLET
FS75 to FS250Silent filters
FS25 and FS50Silent filters
INLET
OUTLET
Silentfilters
Dimensions in mm Complete filter withpaper cartridge reference
Paper cartridgedesignation and referenceA ØB C
FS25 70 64 M1/4” 358226 04 : 358227FS50 98 81 M1/2” 360390 06 : 357950FS75 113 152 M3/4” 357920 14 : 357924FS100 168 152 M1” 362638 18P : 357925FS125 179 160 M1”1/4 357921 18P : 357925FS200 322 255 M2” 357922 230P : 357926FS250 330 255 M2”1/2 357923 230P : 357926
14
Accessories
• High steel painted filter• Movable polyamid bag, 80 μm mesh, capacity : 55 L• Easy quick fixing of the bag• Movable cover with observation window• Highly efficient protection for pumps running in very dusty environment
Dimensions
Dust separator withremovable bag
DN 80
DN 80
3 Ø15 Ø553
1272
1080
650
614
3 x Ø15 sur Ø553
Ø450
References
Separator 718548
Replacement bag 361714
Dust separator withremovable bag
Specifications are subject to be changed without notice
Dimensions
• High steel painted tank or stain-less steel tankwith take-down upper part
• Up and down leds• Evacuation by ball valve
Liquid cyclonicseparator
References
High steel separator 616113
Stainless-steel separator 619058
-150
053
0
environ 590
Female G2“
Female G2“
Liquid cyclonic separator
VACU
UM
pumps
15
• 1/4” differential taps for gauges• The precleaner, dust cyclonic separator, has an efficiency of 85% at 15 micron• Rugged construction• Casting for "SM" type has 4 unthreaded tap holes reserved for possible bracket mounting• Running temperature (continuous) : -25°C to +100°C
References
AccessoriesInlet vacuum precleaner filter
Specifications are subject to be changed without notice
“SM” TYPE G3” G4”
Filter reference SM301 : 360794 SM401 : 361321
“SMCT” TYPE G3” G4”
Dual filters reference paper SMCT301PA : 617518 SMCT401PA : 617519
polyester SMCT301PO : 617520 SMCT401PO : 617521
Flanges DN80 : 617513 DN100 : 617514
Bracket for mural fixing 617512 X 2
Transparent polycarbonate tank 362250 x X
C’
C
D
BB
E
G
AA’
1/4” 1/4”
A’A
B
G
ED
C’
CF1/4”
Optional flange Optional flange
OUTLETINLET
for M14 thread
INLET
“SM” filters “SM” + “CT” filters
OUTLET
Dimensions
“SM” Inlet Coupling Filter Weighttype filter Outlet A A’ B C C’ D E F G flow flow
DN(OPTION) mm m3.h-1 m3.h-1 kgSM301 G3” DN80 - PN10/16 479 527 251 343 383 427 333 254 635 650 15SM401 G4” DN100 - PN10/16 479 537 251 343 383 427 333 254 635 900 15
SM301+CT 301PA/PO G3” DN80 - PN10/16 479 527 251 715 755 427 333 635 510 650 30SM401+CT 401PA/PO G4” DN100 - PN10/16 479 537 251 725 765 427 333 635 765 900 30
16
Accessories Liquids traps forvacuum pumps
Specifications are subject to be changed without notice
• High efficiency to drain liquids in vacuum pipeline• Plexiglas or polycarbonate cylinder• Wall fixation or direct fitting on machine support
Options
220
148
349
152
170
Depth :
Automatic drain
• Pyrex cylinder• Pyrex bottle fixed under the trap to drain condensates• Mechanical float which stops the vacuum if too much liquid inside• Fitting of an automatic liquid drain under the trap :
Allows to drain the system without stopping the processAutomatic drain
Dimensions and characteristics
K
C F3 B
1/2”
I
JG G
250m
l:16
0
500m
l:20
0
1000
ml:
250OPTION
ØD
ØH
ØH
A
F1
F2
3NG – 4NG – 5 – 6 type drain trap1 and 2 NG type drain trap
Cylinder material Flowm3/h-1
Dimensions expressed in mm WeightkgA B C ØD F1 F2 F3 G ØH I J K A' B'
1NG plexiglas or pyrex 30 125 320 193 100 45 45 291 3/4" 4 x Ø7 10 20 145 3
2NGpolycarbonate 100 162 420 25 1"1/4 2 x Ø7 10 33 130 5pyrex 162 415 193 100 25 45 388 1"1/4 4 x Ø7 10 33 130 5
3NG plexiglas or pyrex 280 230 470 318**/229* 180 2" 84NG polycarbonate** or painted steel* 465 229 375 318**/229* 194 2"1/2 85 polycarbonate** or painted steel* 650 343 467 403**/327* 251 3" 515 383 146 polycarbonate** or painted steel* 650 343 467 403**/327* 251 4" 525 383 14
Optional PYREX bottle
250m
l:16
0
500m
l:20
010
00m
l:25
0
B’B
G G
A’
A
ØD
C
1/2”
Optional PYREX bottle
1NG 2NG 3NG 4NG 5 6Filtration capacity m³.h-1 30 100 280 465 650 900Inlet - Outlet 3/4" 1"1/4 2" 2"1/2 3" 4"With PLEXIGLAS CYLINDER without mechanical float 613589 716600** 720807** 719920** 717786** 721107**
with mechanical float 713590 716565** 720808** 720811** 720813** 721108**With PYREX CYLINDER without mechanical float 717757 716601 720809* 719437* 717740* 721109*
with mechanical float 713099 716592 720810* 720812* 720814* 721110*250cc PYREX Bottle mounted under the trap with : 615441500cc PYREX Bottle mounted under the trap with : 6154421000cc PYREX Bottle mounted under the trap with : 615443Flanges DN80 DN100
617513 617514Bracket for wall fixing 619907 617512Pneumatic automatic drain Automatic drain + control board 816002Electrical automatic drain Automatic drain + control board 816003* Painted steel cylinder - ** Polycarbonate cylinder
1NG – 2NG – 3NG –5 type drain trap
Optional flange(5 and 6 type)
VACU
UM
pumps
17
Accessories"SPIREACIER" specialhoses for vacuum
Specifications are subject to be changed without notice
Air coolercopper-aluminium cooling exchanger
Air cooler
PNEUROP/ISO connection parts
1/2” 3/4” 1” 1”1/4 1”1/2 2”MM equal 350473 350476 350477 350480 350482 350484
1/2” - 3/4” 3/4” - 1” 1” - 1”1/4 1”1/4 - 1”1/2 1”1/2 - 2”MM 350474 353551 350478 350481 350483
Crimped hose 1/2” - Ø14 3/4” - Ø20 1” - Ø25 1”1/4 - Ø30 1”1/2 - Ø35 2” - Ø45 2”1/2 - Ø64 DN80 DN100600 mm 670633 606086 618265 670650 618267 618149 618956 618269 6182701000 mm 612919 604422 617372 607058 606455 606099 618957 617833 6178341500 mm 616362 618264 618266 610457 618268 607592 618661
Hose by 1/2” - Ø14 3/4” - Ø20 1” - Ø25 1”1/4 - Ø30 1”1/2 - Ø35 2” - Ø45 2”1/2 - Ø64 DN80 DN100the meter 059656 056350 060596 056351 056352 056353 061707 061409 061412Connections batch* 618271 618082 618083 618084 618085 618086 618958 618272 618273
* 2 bushings + clamps and 2 FF rotating nuts + gaskets
Suction hoses
Special vacuum "SPIREACIER" hoses with 2 rotating nuts
Special vacuum "SPIREACIER" hoses with 2 rotating nuts
BRASS straight unions
Diameter DN 25 DN 40 DN 50 DN 80ALU adapter M1”/DN25 KF : 117133 M1”14/DN40 KF : 117134 M2”/DN50 KF : 117132 DN80/DN80 ISOK : 117129ALU clamping collar 361638 361639 361640 4 x clamps 4 x 361653Centering ring INOX/VITON : 361641 INOX/VITON : 361642 INOX/VITON : 361643 ALU/Perbunan : 361650Stainless steel hose 500 mm 361644 361646 361648 361651Stainless steel hose 1 m 361645 361647 361649 361652Stainless steel short bellows 361655 361656 361654 361657
Type AF072 A F216 AF510Power supply 1-ph 230V - 50 Hz 3-ph 400V - 50HzInlet - Outlet 3/4” 1”1/4 2”Fan power 40 W 95 W 145 WReference 361325 361326 361327
Check valve
3/8" 1/2" 3/4" 1" 1"1/4 1"1/2Brass check valve for vacuum 654225 654226 654227 654903 654904 654905
18
Specifications are subject to be changed without notice
Vacuum solenoid valves
• Vacuum solenoid valves 3/2" allowing vacuum opening or atmospheric pressure opening(example : handling by suckers)
• The piston is closed or opened by vacuum or compressed air• Standard power supply : 230V – 50 Hz – others on request
References
• Minimum vacuum required :–200 mbar relative or 813 mbar absolute
• Vacuum brake by atmospheric pressure
Controlled by compressed air
• Minimum pressure : 4 bar – maxi pressure : 7 bar• Vacuum brake by over pressure or atmospheric pressure• To modify NC in NO, R and P ports are reversed
Size 1/4” 3/8” 1/2” 3/4” 1”NF 359702 359703 359704 359705 359706NO 359707 359708 359709 359710 359711
Size 1/4” 3/8” 1/2” 3/4” 1”NF/NO 359712 359713 359714 359715 359716
Size G1/2” G3/4” G1” G1”1/4 G1”1/2 G2”
Vacuum solenoid valve NF 2/2 (ASCO) 357830 358060 357407 358854 357888
NF 2/2 (CS) AD-15 AD-20 AD-25 AD-35 AD-40 AD-50
360023 360024 360606 360025 360026 360027
Ball valve with electric actuator Time 25 s. 25 s. 20 s. 35 s. 35 s.
230V – 50 Hz supply ER - Brass 360860 359539 359718 360859 359163
ER - INOX 361342 361334 361596 361520 361336
Time 7/10 s.
EK - Brass 360761 361302 361337 361335 361547
EK - INOX 361164 361250 361165 361338 361350
2-ways ball valve Ref. 360873 360874 360875 359528 360876 360877
with pneumatic actuator, Pilot electric actuator 5/2 – 230V – 50 Hz 359959
immediate opening Flow reducer flow reducer (opening/closing speed) 2 x 360758
Size DN65 (2”1/2) DN80 (3”) DN100 (4”) DN125 (5”) DN150 (6”)
Double acting butterfly valve Ref. 360878 359114 360626 360627 360628
with pneumatic actuator Pilot electric actuator 5/2 – 230V – 50 Hz 359959
immediate opening Flow reducer flow reducer (opening/closing speed) 2 x 360758
Butterfly valve with electric actuator Time 20 s. 20 s. 20 s.
230V - 50 Hz supply ER 359719 359720 359721
Time 12/20 s. 12/20 s. 25/40 s.
EK 361449 361613 361614
5
4
3
2
1
P = exhaustA = usingR = suction
P = suctionA = usingR = exhaust
P = exhaustA = usingR = suction
P = suctionA = usingR = exhaust
Controlled by vacuum
VACU
UM
pumps
19
Specifications are subject to be changed without notice
Accessories
1Vacuum solenoid
valve
2Ball valve with
electric actuator
32-ways ballvalve with
pneumatic actuator,immediate opening
4Double actingbutterfly valve
with pneumaticactuator,
immediate opening
5Butterfly valve
with electricactuator
7Manual ball
valve
8Manual
butterfly valve
6Angle-seat valve
pneumaticallyoperated,
immediate opening
References (continued)
Size G3/8” G1/2” G3/4” G1” G1”1/4 G1”1/2 G2”
Angle-seat valve, NO 359322 359390 359391 359354 358798 359392 358800
pneumatically operated, NF 359321 359352 359387 359388 358799 359389 359927
immediate opening Pilot banjo solenoid valve 3/2 NF - 230V - 50 Hz 1/8” banjo solenoid valve 3/2 NF - 230V - 50 Hz 1/4”
359928 359929
Size G3/8” G1/2” G3/4” G1” G1”1/4 G1”1/2 G2”
Manual ball valve 350945 350946 350947 350948 350949 350950 350951
Manual butterfly valve Size DN50 DN80 DN100 DN125 DN150
361304 360467 361351 361347 361348
Size 1” 1”1/2
4 ways manual valve 362556 362557
Other models on request (different power supplies and valve materials)
ER : possible intermediate position
EK : ON/OFF position.
9
8
7
6
94 ways
manual valve
20
Accessories
Specifications are subject to be changed without notice
Vertical vacuum receivers
G1
Y
X
Z
Ø
G2
W
F
DC
E XB
A
1
1 1
• All our vacuum receivers are made of black steel sheet, painted externally with an undercoatof beige alkyd resin lacquer, family 1, class 4a and a finishing coat
• On request, they can be internally and externally hot zinc-dipped by full immersion• The profile of heads includes a large edge radius• Lengthwise and circular welds are made by electric flux welding• Couplings are welded by manual arc welding
Characteristics
1 inlet and 1 outlet tapped to gas pitchfor standard version, or 2 inlets and2 outlets in galvanized version.
Equipment
- 0 to 1013 mbar vacuum gauge,- Manual bleeder or automatic
sequential bleeder on request
Available capacities
Available on stock :500, 1000 and 2000 litres,On request, short time300, 800, 1500, 3000 and 5000 litres
Vertical vacuumreceiver
Ø80 PV 1/4” vacuum gauge
Pumps suction
Inspection hole if galvanized
1/2” bleed tap
Net-work
References and dimensions
Handling lug (only for 1000/2000 l)Lifting ring (except for 1000/2000 l)
Galvanized receivers :in the 1000 and 1500 litrereceivers, dimensions ofbossings GA and G2 are 2“.In the 2000 to 5000 litrereceivers, dimensions ofbossing G1 is 2“ and G2is replaced by a 100/150inspection orifice.
Capacity / volume in litres 300 500 800 1000 1500 2000 3000 5000Receiver alone with primer
and painting 610593 610594 610595 610596 610597 610598 610599 610600
Receiver with equipment* 710601 710486 710487 710488 710489 710490 710602 710603
OPTIONS 300 500 800 1000 1500 2000 3000 5000Automatic electro-pneumatic 816002vacuumdrain electrical 816003Network valve 1”1/4 610853 1”1/2 610854 2” 610855 2”1/2 610856Ø 550 650 850 850 1000 1000 1200 1400A 1545 1880 1635 2030 2140 2690 2970 3670B 1345 1570 1390 1780 1840 2340 2660 3280C 350 380 410 410 470 470 510 540D 150 150 165 165 170 170 160 160E 1100 1300 1100 1450 1600 1600 1600 1600
base 3 feet 120° (Ø24)F 520 620 620 620 765 765 890 1030W 1”1/2 1”1/2 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”X 1”1/4 1”1/4 1”1/2 1”1/2 2” 2” 2”1/2 2”1/2Y 1”1/2 1”1/2 1” 1” 1” 1” 1”1/4 1”1/4Z 3/4” 3/4” 1” 1” 1” 1”1/4 1”1/2 2”Weight kg 70 120 150 210 290 370 530 750Standard receivers in stock Special and horizontal receivers can be fit to the customer's drawing.Equipment* : Vacuum gauge 0 to 1013 mbar, manual drain valve and plugs.Nota : 500, 1000 and 2000 litre receivers can't be galvanized as they are already painted.
VACU
UM
pumps
21
Specifications are subject to be changed without notice
P.I.D. electronic controllerThe P.I.D. controller allows , from a fixed pressure threshold, to open a valve plus or minus to maintaina pressure in the network nearest to the fixed pressure threshold.
• Power supply : 230V – 50 Hz
Complete unit with a pressure sensor from 1100 to 0 mbar absolute 718245
from 0 to – 1000 mbar relative 718246
ball valves ER type (female stread) butterfly valve ER type (flange)
G3/4” G1”1/4 G2” DN80 DN100 DN150
Motorized valve see page 18 360860 359718 359163 359719 359720 359721
190 313
253
PIRANI vacuum gauge• Measurement range from 10-4 to 1300 mbar• Delivered with digital display• 2 alarm contacts• Power supply : 230V - 1 phase - 50 Hz• Gauge connection : NW 25 KF• Included 3 meters cable between display and gauge
NB : other cable length and power supply available on request
Vacuum gauge references
Complete set (display / gauge / supply / cable) without outlet contact 362663
Complete set (display / gauge / supply / cable) with 2 alarm contacts 361615
AccessoriesElectronic controllerfor vacuum
Dimensions
Controller references
Accessory and option references
96 100
48
about 10 mm 92 mm +0,5
45m
m+0
,5
MAXMIN
SET
AL 1AL 2AL 3
Cut out to embed
22
Digital vacuum switch• Power supply : 230V - 50 Hz• Output : 1 or 2 adjustable dry contacts• Sensor : 4/20 mA
References
Ø50 vertical connection 1/8” 363032
Ø63 vertical connection 1/4” 357037
Vacuum gauges• Working pressure : -1/0 bar
References
Vacuum switch XMLBM02V2S11 hysteresis mini 130 mbar 352997
Vacuum switch FP6A 1/2” hysteresis mini 30 mbar 357549
Mechanical vacuum switches• Adjustable threshold• Adjustable hysteresis
Accessories Vacuum switchesand vacuum gauges
With 1 dry contact with NO-NC switch 360290
With 2 dry contacts with NO-NC switch 359649
Vacuum sensor 0/1100 mbar 358221
Pressure sensor 0/16 bar 357651
Specifications are subject to be changed without notice
Dimensions
References
VACU
UM
pumps
23
Area defining ATEX
Specifications are subject to be changed without notice
ATEX – HAZARDOUS AREAS
The European directive 94/9/CE, applicable from the 30th of June 2003, states the conditions to be met bythe equipment items for use under potentially explosive atmosphere.
II 2 G IIB T4
: � corresponds to the European directive 94/9/CE� protection against explosions
II : Groupe I � equipment for underground miningGroupe II � equipment for explosive atmosphere, other than mining.
2 : Hazardous area zones and equipment categories
G : G � gas or vapourD � dust
IIB : 3 subdivisions for gas of group II according to MESG(Maximum Experimental Safety Gap)
IIA � butane, propane,…IIB � ethylene,…IIC � hydrogen, acetylene,…
T4 : Maximum surface temperature.
Temperature classification T1 T2 T3 T4 T5 T6
Maximum surface temperature 450°C 300°C 200°C 135°C 100°C 85°C
Equipmentcategories
Place in which an explosive atmosphereis present :
Zone classifications
Gas or vapour Dust
1 Continuously or for long periods 0 20
2 In normal operation occasionally 1 21
3 For a short period only 2 22
EVISA ATEX version
24
Specifications are subject to be changed without notice
Lubricated rotary vane vacuum pumps, secure and reliable,designed for low and medium vacuum
Time (s.)
1000 L Receiver
Average evacuation time (50 Hz)
E300
E200
E100.2
E65.2
10
0
20304050
100
150
200
400
600
800
1000
5 10 15 20 30 40 50 60 70 80 90 100 110 120 130 360330150 165 180 200 220 240 270 300
Abso
lute
pres
sure
(mba
r)
Characteristics
0,1 0,5 10,1
2 3 4 5 6 7 98 10-1
20 30 40 60 80 100-10
200 300 400 600 800 1013 mbar-100 kPa
700600
500
400
300
200
10090807060
50
40
30
20
1098765
4
3
2
1
E300
E200
E100.2
E65.2
0,1 0,5 1 2 3 4 5 6 7 98 10 20 30 40 60 80 100 200 300 400 600 800 1013 mbar
Flow
rate
(m3 /
h)
Absolute pressure
Capacity - pressure curve without gas ballast (50 Hz)
Type HV : High vacuum
Type MV : Medium vacuum
NOMINALCAPACITYm³.h-1
PNEUROPCAPACITYm³.h-1
ENDVACUUMmbar
Pwo
mbar
Cwo
kg.h-1
MOTORPOWERkw
ROTATIONSPEEDrpm
NOISELEVELdB (A)
OILFILLING
L
WEIGHT
kgwithoutgas ballast
withgas ballast
50 Hz 60 Hz 50 Hz 60 Hz HV HV MV 50 Hz 60 Hz 50 Hz 60 Hz�E65.2 65 78 63 75 0,1 1,2 3 39 1,8 1,5 1,8 1450 1740 65 4 70�E100.2 96 115 94 112 0,1 1,2 3 50 3,2 2,2 2,64 1450 1740 67 4 80�E200 190 228 185 222 0,1 1,2 3 48 4,5 4 4,8 1450 1740 71 7 115�E300 288 345 263 315 0,1 1,2 3 50 7 5,5 6,6 1450 1740 73 7 190
Pwo : Maximum admissible of water vapour pressureCwo : Pumping capacity of water vapour
VACU
UM
pumps
25
Specifications are subject to be changed without notice
Dimensions E65 to E300 ATEX Base frame dimensionsA B C A' C' D E F G H H' I J K L ØM ØM' ØE ØS V W X Y ØZ
�E65.2 683 385 365 25 379 67 80 270 322 214 -- 243 245 15 574 M10 M8 1"1/4 1"1/2 290 370 335 365 11
�E100.2 751 385 365 25 379 67 80 270 322 214 -- 269 245 15 574 M10 M8 1"1/4 1"1/2 290 370 335 365 11
�E200 873 504 401 -- 415 108 149 375 364 295 295 266 343 20 635 M10 M10 2" 2" 290 370 430 460 11
�E300 1055 584 421 -- 436 145 259 450 386 363 363 318 412 25 820 M10 M10 2" 2" 440 500 590 620 12
B
FD
J
XY
4 x ØZ
C G
C’15
0I
VW
K
Cooling air
OilSuction
Exhaust
Dimensions
• CE Marking for explosible atmospheresII 2 G IIB T4 (INERIS Certificate - n°19392/06)
• Continuous running from atmospheric pressure to end vacuum• High water vapours avacuation• Standard temperature security, PT100 temperature sensor,
with intrinsic security• Pump delivered with MV99S synthetic oil
AL
I H
ØM’ ØM’ ØSE
A’
ØM ØMØEH’
Lubricated rotary vane vacuum pumps
ATEX pump references
Option references
�E65.2 �E100.2 �E200 �E300type HV with MV99S oil filling + gas ballast 821315 821316 821317 821318
type MV with MV99S oil filling + gas ballast 819620 819621 819622 819623
�E65.2 �E100.2 �E200 �E300Fitted suction filter (CE ATEX) PO : polyester 619884 619885
Stainless steel hose for inlet or outlet 619886 619887
Base frame assembly 670805 670806 616595
Flame protection DN50 362647 DN80 362631
Power supply of intrinsic security for PT100 0-10V outlet 362640
Dimensions expressed in mm
26
3VK to 60V ARICA
Capacity/pressure curveEvacuation time with a 100 L receiverPressure through a nozzleEvacuation time with a 1000 L receiver
Arica 3VK/6VK Arica 10V/15V/25V Arica 60V
Arica 3VK/6VK Arica 10V/15V/25V Arica 60V
Ø Nozzle (mm)Time (s)
Flow rate (m3/h)
Ø Nozzle (mm)Time (s)
Flow rate (m3/h)
Ø Nozzle (mm)Time (s)
Flow rate (m3/h)
Specifications are subject to be changed without notice
NOMINAL PNEUROP END MOTOR ROTATION NOISE WEIGHTCAPACITY CAPACITY VACUUM POWER SPEED LEVELm3.h-1 m3.h-1 mbar abs. kW rpm dB(A) kg
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz�3VK 4,0 4,8 3,3 4,0 100 0,25 0,30 1400 1680 58 6,5�6VK 7,0 8,4 6,5 7,8 100 0,30 0,36 1400 1680 59 11,5�10V 11 13 9,7 11,5 150 0,37 0,44 1450 1740 60 20�15V 17,5 21 16,0 19,0 150 0,55 0,66 1450 1740 63 29�25V 27 32,5 26,0 31,0 150 0,75 0,90 1450 1740 65 34�60V 55 66 53,0 63,6 100 1,50 1,80 1450 1740 66 50
Characteristics
Capacity - pressure curve and average evacuation time (50 Hz)
27
• Oil-free rotary vane vacuum pumps• Built-in 25μ suction filter (ARICA 10V to 25V)• Running and maintenance low costs• Compact assembly under box for intensive cooling
and total protection (ARICA 10V to 60V)• Low noise
VACU
UM
pumps
Dimensions
Oil-free rotary vane vacuum pumps
Specifications are subject to be changed without notice
A B C D E F G H I J K L M ØR ØS T�10V 377 234 245 28.5 323 M6 120 196 65 65 66 194 22 1/2” 3/4” Pg10�15V 445 295 278 24 390 M6 160 235 75 90 74 234 10 3/4” 1” Pg15�25V 445 295 278 24 390 M6 160 235 75 90 74 234 25 3/4” 1” Pg15
I J
H
F D
K M
EA
T
C
GLB
179
23 355403
652215
293157
39
350
325
36
148
75
127 17
0
16 16
82
112132
185
8992
278100
70
30
1171010
6080
220 160
121
6312
4 143
Arica 60VArica 10V/15V/25V
Exhaust
SilencerSuctionG 1/8”
4 holes Ø7
Silencer
SuctionG 3/8”
4 trous Ø7
Exhaust ØSSuction ØR
SuctionG1”1/4
4 holes M10
Arica 3VK Arica 6VK
Dimensions expressed in mm
28
Specifications are subject to be changed without notice
ARICA
1Suction filter with
paper, polyesteror activated
carbon cartridges
2Suction hoses
3Adjusting valve
fitted on T-square
4Vacuum gauge
Standard configuration example :
• ARICA vacuum pump• PA suction filter
VACU
UM
pumps
29
Specifications are subject to be changed without notice
Pump references
Accessory and option references
�3VK �6VK �10V �15V �25V �60V
Fitted inlet filter PA : paper 25PA* 38PA* 51PA* 76PA 126PA
714926 362243 357947 706190 706192
Fitted suction hoses see page 17 618981 712931 712926 712926 712927
Non fitted adjusting valve 1/4” 703790 1/2” 702434
Non fitted vacuometer 363031 363032
Adjusting valve and vacuometer Ø40 cross mounted 714927 770581 770582 716746
Fitted check valve MF1/4” MF1/2” MF3/4” 1”1/4
670175 670583 670584 616747
Shifted mounting feet 670510
Direct starters without regulation 3-ph 400V 770573 770495 770496
3-ph 230V 770495 770496 770498
1-ph 230V 770631
with LG7 control board 3-ph 400V 710421 710422 710423
3-ph 230V 710429 710430 710432
1-ph 230V 770471
* It is advised to equip the pump with a hose for easier change of the cartridge
3
4
2
1
Accessories
�3VK �6VK �10V �15V �25V �60V
1-ph 230V 816596 816597
3-ph 230/400V 870098 870254 870255 814783
30
SIRELLA
Characteristics
Specifications are subject to be changed without notice
Capacity - pressure curve and average evacuation time (50 Hz)
NOMINALCAPACITYm3.h-1
MOTORPOWERkW
ENDVACUUMmbar abs.
CONTINUOUSVACUUMmbar abs.
ROTATIONSPEEDtr.min-1
NOISELEVELdB (A)
WEIGHT
kg50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz�SIRELLA 100 95 114 3 3,6 50 150 2850 3420 78 150�SIRELLA 150 145 174 4 4,8 50 150 2850 3420 79 165�SIRELLA 250 250 276 7,5 9 50 150 2850 3420 79 290�SIRELLA 350 320 348 9 10,8 50 150 2850 3420 79 305
300
250
200
150
100
50
00 200 400 600 800 1000
0 5 10 15 20 30 40 50 60 70 80 90 100
1000
800
600
400
200150
Average evacuation time1000 L receiver
Flow rate(m3.h-1)
Time (s.)
Abso
lute
pres
sure
(mba
r)
Absolute pressure (mbar)
SIRELLA 100SIRELLA 150SIRELLA 250SIRELLA 350
Pump references
Accessory and option references
�SIRELLA 100 �SIRELLA 150 �SIRELLA 250 �SIRELLA 350Additional silencer [A] 619319 620514Adjusting valve fitted on T-square(without filter)
Male 1"714979
Male 1"1/4713841
Male 2"714979
Fitted suction filter see page 12 PA : paper 126 PA : 619888 201 PA : 619891 201 PA : 715350PO : polyester 126 PO : 619889 201 PO : 619892 201 PO : 715351CH : carbon 126 CH : 619890 201 CH : 619893 201 CH : 715352
Fitted vacuum meter 617536Suction hose see page 17 715394 712927 712929Base frame assembly 619881 620515Base plate for LG7 box 617407Direct starter without control
panel3-ph 400V 770498 770499 7705003-ph 230V 770499 770500
with LG7 start andstop system
3-ph 400V 710425 710426 7137463-ph 230V 710433 710434
Constant vacuum electrovalve 619894 619895 620516MB150S gear box oil 0.5 l per pump SIRELLA 100 - 150
1 l per pump SIRELLA 250 - 3501 litre can : 6196262 litre can : 619627
�SIRELLA 100 �SIRELLA 150 �SIRELLA 250 �SIRELLA 3503-ph 230/400V 818222 818223 8182243-ph 400V 818225
31
VACU
UM
pumps
Dimensions
• Claw vacuum pumps• Very good efficiency• Contact-free compression• Oil-free compression• Air cooling• Low maintenance
Claw vacuum pumps
Specifications are subject to be changed without notice
E
C
L
B’
B
K H
H’
A
C’ØS’
G’
G
F F’ØS
J IØM
ØE
D
(A)
A B C B' C' D E ØE F G H ØS F' G' H' ØS' I J K L ØM�SIRELLA 100 829 461 518 428 513 182,5 214 G1" 125 60 490 G1"¼ 62 218 692 G1"¼ 51,5 420 34 360 M10
�SIRELLA 150 842 461 518 428 517 172 214 G1"¼ 125 60 470 G1"¼ 71 205 672 G1"¼ 51,5 420 34 360 M10
�SIRELLA 250 995 538 651 538 651 222 269 G2" 149 86 641 G2" 51,5 555 34 470 M10
�SIRELLA 350 1032 538 651 538 651 214 269 G2" 149 86 625 G2" 51,5 555 34 470 M10
Dimensions expressed in mm
32
Electric supply : 400V+N+EPneumatic supply : 10 bar maxi
Standard power supplies
EVOLIS
750
700
600
500
400
300
200
100
0.01 0.05 0.1 0.5 1 5 10 50 100 200 500 1000 mbar
MS 800
MS 450/MS 500
MS 350/MS 400
MS 150/MS 170MS 150
50 Hz60 Hz
MS 350
MS 450
MS 800
Flow rate (m3.h-1)
Absolute pressure
Specifications are subject to be changed without notice
TYPE �MS 150 �MS 170 �MS 350 �MS 400 �MS 450 �MS 500 �MS 800FREE AIR DEPLACEMENT m3.h-1 50 Hz 120 250 340 560
60 Hz 140 140 290 290 410 410 700NOMINAL CAPACITY m3.h-1 50 Hz 135 280 390 720
60 Hz 165 165 345 345 480 480 840END VACUUM mbar 50 Hz 0,3 0,3 0,04 0,04
60 Hz 0,15 0,15 0,07 0,07 0,03 0,03 0,015Pa 50 Hz 30 30 4 4
60 Hz 15 15 7 7 3 3 1,5MOTOR POWER kW 50 Hz 5,5 11 15 22
60 Hz 7,5 7,5 15 15 18,5 18,5 30MOTOR SPEED rpm 50 Hz 2900 2900 2900 2900
rpm 60 Hz 3550 3550 3550 3550 3550 3550 3550STANDARD PORT SIZE Suction 2” 2” 2” 2” DN80 DN80 DN100
Discharge silencer 2” 2” 2” 2” DN80 DN80 DN80HIGH VACUUM Suction DN 50 ISO KF DN 100 ISO KPORT SIZE Discharge silencer 2” DN80COOLING WATER L/min 20°C 12 12 14 14 16 16 20CONSUMPTIONFREQUENCY CONVERTER no yes no yes no yes no
Characteristics
Capacity - pressure curve
33
• End vacuum 10-2 mbar : rapid decrease• Patented cooling system with water path through
the inside of the screw rotors• Anti-corrosion screw treatment• Low maintenance costs• Starting board with digital display• Screw running at low temperature• Running from atmosphere to end vacuum• Water inlet temperature sensor• Air outlet temperature sensor• Rotation direction controller• Cooling water management at the start and the stop of the pump• Inlet filter (standard feature)• Discharge and shut-off pneumatic valve (standard feature)• PNEUROP/ISO K connection (on deep vacuum version)• ATEX version : contact us
VACU
UM
pumps
Dimensions
B
J
I
A
GH
F D
C
E20
Suction ØA
WaterinletØE
Water outletØE
4 holes Ø14for groundfixation
Exhaust ØR
Oil-free screw vacuum pumps
Specifications are subject to be changed without notice
A B C D E F G H I J ØA ØR ØE WEIGHTkg
�MS 150/MS 170 1335 1250 687 770 421 284 785 425 810 295 2” 2”/ 50KF 1/2” 420�MS 350/MS 400 1665 1250 731 865 465 437 881 438 840 325 2” 2”/ 50KF 1/2” 520�MS 450/MS 500 1725 1350 750 977 473 437 995 442 858 345 DN80 DN80/DN100 ISO K 1/2” 620�MS 800 1870 1350 875 1035 559 464 1053 477 954 443 DN100 DN80/DN100 ISO K 1/2” 930
�MS 150 MS 170* �MS 350 MS 400* �MS 450 MS 500* �MS 800
Standard version 3-ph 400V 917554 918386 917555 918387 917556 918388 917557
Deep vacuum version 3-ph 400V 918881 918882 918883 918884 918885 918886 918887
�MS 150 MS 170* �MS 350 MS 400* �MS 450 MS 500* �MS 800
Stainless steel exhaust 617558 617559 617560 617561
silencer–condenser
Suction hose 617562 617563 617564
* Model equipped with a frequency inverter allowing to run at 60 Hz from a network at 50 Hz
Pump references
Accessory and option references
Dimensions expressed in mm
34
PS
Specifications are subject to be changed without notice
Evacuation time curves
Characteristics
Time (s)
Evacuation time with a 20 L receiver
Electric supply : 1-ph 230V - 50/60 Hz
Standard power supply
1Suction filter with
paper, polyesteror activated
carbon cartridge
2Check valve
Standard configuration example
• PS piston vacuum pump• PA suction filter
Pressure (mbar abs.)
NOMINAL RELATIVE MOTOR ROTATION NOISE WEIGHTCAPACITY VACUUM POWER SPEED LEVELL.min-1 mbar W rpm dB(A) kg
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz�PS 2V 47 55 -900 200 1465 1755 57 58 7�PS 5V 81 90 -900 170 1465 1755 57 58 9�PS 7V 106 120 -900 250 1425 1745 57 58 9�PS 12V 168 205 -900 360 1425 1745 57 58 9�PS 5VH 58 66 -980 170 1465 1755 57 58 9�PS 7VH 79 90 -980 250 1425 1745 57 58 9�PS 12VH 123 150 -980 360 1425 1745 57 58 9
135
120
105
90
75
60
45
30
15
00 100 200 300 400 500 600 700 800 900 1000
PS 2V (50 Hz)
PS 5V (50 Hz)
PS 7V (50 Hz)
PS 12V (50 Hz)
35
Oil-free piston vacuum pumps
VACU
UM
pumps
Specifications are subject to be changed without notice
D
GH
ØE
4xØ7
AB K
• Suitable for many types of applications in dry and wet environments• Oil-free running• Compact construction and low noise• Direct coupling• Low energy consumption• Optional air filter
4 x Ø7
140.518141
40
G1/4”19
8
112162
==
4xØ7
J
D
ØE
HGA
BK
Exhaust silencer
PS 5V / PS 7V / PS 12VExhaust silencer
PS 5VH / PS 7VH / PS 12VH
PS 2V
A B D ØE* G H J** K�PS 5 203,5 240 198 G 1/4” 112 162 40 41�PS 7 203,5 240 198 G 1/4” 112 162 40 41�PS 12 223 275 242 G 3/8” 118 162 40 52
* : female connection**: only for V version
�PS 2V �PS 5V �PS 7V �PS 12V �PS 5VH �PS 7VH �PS 12VH
1-ph 230V 416082 416083 416085 416094 819903 819904 819905
�PS 2V �PS 5V �PS 7V �PS 12V �PS 5VH �PS 7VH �PS 12VH
Fitted air filter PA : paper 25PA : 38PA : 25PA : 38PA :
619068 619069 619068 619069
Check valve 670175 618996 670175 618996
Adjusting valve and vacuometer 670176 618997 670176 618997
Atmospheric pressure solenoid valve 359791
Suction hose MF 1/4” : MF 3/8” : MF 1/4” : MF 3/8”:670478 618981 670478 618981
2
1
Dimensions
Pump references
Accessory and option references
Exhaust silencer
36
KAV
Specifications are subject to be changed without notice
1000900800700600
500
400
300
200
150
120100
80
60
40
20100
0100200300460 400
18001700160015001400130012001100
Y006V
3
Y011V
Y020V
Y030V
X40 B1
X05 B2
3
4
7.5
X08 M14
X06 M1
2.2
2.2
5.5
4
5.5X06 B2
7.5
5.5
43
X08 B29.5
X11 B2
18.5
15
X11 M1
18.5X09 M2
11
15
5.5
7.5
9.2
11
11
11
159.2
11
15
18.5
18.5
22
X10 M2
X11 M2
• Compact design• No contamination (without oil)• High efficiency• Low maintenance• Horizontal of vertical axis mounting• For air, non explosive or non harmful gases or gas mixtures• Fluid and ambient air temperature must not exceed 40°C
Flow rate (m3.h-1)
SINGLE IMPELLER POWER NOISE WEIGHTV and M1 : single stage LEVELB1 : double stage kW dB(A) kgY006V 1-ph/3-ph 230/400V 0,38 58 13Y011V 1-ph/3-ph 230/400V 0,90 64 16Y020V 1-ph/3-ph 230/400V 1,50 68 24Y030V 3-ph 230/400V 2,20 70 32X40B1 3-ph 230/400V 2,20 72 32,5X06M1 3-ph 400 2,2/3/4 71,6 35,2X08M1 3-ph 400 3/4/5,5/7,5 77,4 68X11M1 3-ph 400 5,5/7,5/ 81,8 98,5
9,2/11/1560 Hz on request
TWIN IMPELLER POWER NOISE WEIGHTB2 : double stage LEVELM2 : single stage kW dB(A) kgX05B2 3-ph 400 2,2/3/4 74 43,5X06B2 3-ph 400 4/5,5 75 61,5X08B2 3-ph 400 5,5/7,5/9,2 80,3 110,5X11B2 3-ph 400 11/15/18,5 85,9 172X09M2 3-ph 400 9,2/11/15/18,5 86,1 158X10M2 3-ph 400 11/15/18,5 87,7 163X11M2 3-ph 400 11/15/18,5/22 89,3 186,5
Δ Pressure (vacuum in mbar)
Single impellerTwin impeller
Characteristics (50 Hz)
Capacity - pressure curve (50 Hz)
321Suction filter and
safety valve onT-connector,
exhaust silencer
5Electronic vacuum
adjusting valve fit-ted on T-connector
Non return valve4
6P.I.D. vacuum
adjusting valve fit-ted on T-connector
TWIN IMPELLER RANGE X05B2 X06B2 X08B2 X11B2 X09M2 X10M2 X11M2Suction filter1 619922 619923 361670* 362240* 361422*
Safety valve fitted on T2 619939 Upon request 619941 425064*
Non-return valve4 619934 619935 619936 Non availableSuction M/F hoses L : 1500 - MF 2" L : 1500 - MM 3" L : 330 - MM 4" L: 330 - MM 5"
712929 719925 719926 721186Sound-proofing hood 425026 425027 425028Silencer3 425057 425059 425060 Non availableElectronic vacuum valve on T5 621294 621295 621296 621302*P.I.D. vacuum valve on T6 621299 621300 621301 621303*
* To be fitted on pipeline37
VACU
UM
pumps
Side channel vacuum pumps
Specifications are subject to be changed without notice
Accessory and option referencesSINGLE IMPELLER RANGE Y006V Y011V Y020V Y030V X40B1 X06M1 X08M1 X11M1
Suction filter1 609454 609455 609456 609455 609456 619921 361670*
Safety valve fitted on T2 619937 619938 620259 620260 619938 619939 Upon requestNon-return valve4 619932 619933 619934 619933 619934 619935 619936Suction M/F hoses L:1200-MF1"1/4 L:1200-MF1"1/2 L:1500-MF2" L:1200-MF1"1/2 L:1500-MF2" L:1500-MM3" L:330-MM4"
712927 712928 712929 712928 712929 719925 719926Sound-proofing hood 425023 425024 425025Silencer3 425055 425056 425057 425056 425057 425059 425060Flow converting valve electrical version 230V - 1ph - 50Hz 425090 425092Flow converting valve electropneumatic version 230V - 1 ph - 50 Hz / 10 bar maxi 425091 425093Electronic vacuum valve on T5 621292 621293 621294 621293 621294 621295 621296P.I.D. vacuum valve on T6 621297 621298 621299 621298 621299 621300 621301
Dimensions
Side channel vacuum pump references
A
B
D
E
K
F
Y006V to Y030V / X06M1 to X11M1 / X40B1 X05B2 to X11B2
F
B
K
L
DØO
AØI
X09M2 to X11M2
A F
ØI ØO
D K
B
L
SINGLE IMPELLERTYPE A B D E F K ØI and ØOY006V Ø250 257 205 230 256 85 1”1/4Y011V Ø286 306 225 255 261 95 1”1/2Y020V Ø325 345 260 296 323 115 2”Y030V Ø373 383 290 325 377 140 2”X40B1 Ø350 370 245 270 458 235 1”1/2X06M1 Ø376 443 290 325 386 140 2”X08M1 Ø454 542 448 478 550 300 3”X11M1 Ø540 645 509 539 638 300 4”
TWIN IMPELLERTYPE A B D F K L ØI and ØOX05B2 366 444 260 570 115 55 2”X06B2 398 474 290 703 140 59 2”X08B2 500 698 448 854 300 82 3”X11B2 593 813 509 1000 300 91 4”X09M2 492 610 478 850 500 112 130X10M2 516 623 478 850 500 112 130X11M2 542 650 510 870 500 110 130
SINGLE IMPELLER RANGE TWIN IMPELLER RANGEPower (kW) Y006V Y011V Y020V Y030V X40B1 X06M1 X08M1 X11M1 X05B2 X06B2 X08B2 X11B2 X09M2 X10M2 X11M2
3-ph 400V 0,38 4160871-ph 230V 0,38 4160973-ph 400V 0,9 4160881-ph 230V 0,9 4160983-ph 400V 1,5 4160891-ph 230V 1,5 4160993-ph 400V 2,2 416090 425040 425000 425012
3 425001 425003 4250134 425002 425004 425014 425015
5,5 425005 425007 425016 4250177,5 425006 425008 4250189,2 425009 425019 42504211 425010 425020 425043 425046 42508615 425011 425021 425044 425047 425087
18,5 425022 425045 425048 42508822 425089
38
RV 5 ROOTSend vacuum : -500 mbar
1. Protection filter with adjusting pipefor relief valve
2. Blower3. Base silencer4. Rubber sleeve5. Non-return valve6. Relief valve
7. Drive guard8. Electric motor9. Silent-blocs10. Electric fan*11. Acoustic hood*12. Outlet silencer** On option
• Oil-less compression• High output• Low noise level• Flow rates from 60 to 2200 m3.h-1
• ATEX version : on request
Specifications are subject to be changed without notice
Weight KgDN Motor Dimensions expressed in mm Fan Without Box
kW a b b’ c d e1 e e2 f g h j k l m n r s v w kW motor30.10 50 5,5/132S 780 117 227 552 60,3 154 446 115 677 531 600 250 166 1031 354 850 1100 1000 789 425 0,25 185 9030.20 80 7,5/132S 864 148 258 650 88,9 195 455 170 746 577 650 300 187 1129 374 950 1200 1060 860 460 0,55 250 11030.30 80 11/160M 864 148 258 650 88,9 195 455 170 746 577 650 300 187 1154 374 950 1200 1060 860 460 0,55 275 11031.20 100 15/160M 1146 172 282 684 114,3 230 640 200 827 765 870 330 240 1270 409 1200 1370 1250 989 550 0,75 360 17031.30 100 22/180M 1146 172 282 684 114,3 230 640 200 827 765 870 330 240 1325 409 1200 1370 1250 989 550 0,75 390 17032.20 100 30/200L 1176 172 282 684 114,3 230 640 200 827 765 870 330 240 1325 409 1200 1370 1250 1019 550 0,75 450 17032.30 150 37/200L 1294 232 352 930 168,3 257 745 230 1038 900 1002 458 275 1624 460 1460 1650 1530 1204 620 0,75 650 270
Dimensions
39
VACU
UM
pumps
Vacuum up to –500 mbar
Q1 : Inlet flow t1 = 2O°CΔt : Temperature increaseabs.P. : Absorbed powermot.P. : Motor power
Lobe vacuum pumps Roots type
Specifications are subject to be changed without notice
Δp/mbar Size Type 30.10 / DN 50 30.20 / DN 80Q1 m3.h-1 66 88 134 163 197 225 254 280 292 103 140 198 229 276 315 355 383 407Δt °C 14 12 11 11 11 11 10 10 10 13 12 11 11 11 10 10 10 10rpm roots 1428 1900 2424 2850 3360 3770 4206 4576 4770 1500 1900 2424 2860 3370 3790 4219 4523 4780rpm mot. 2850 2850 2850 2850 2860 2860 2860 2860 2860 2850 2850 2850 2860 2860 2860 2860 2860 2860
100 kW N abs kW 0,422 0,562 0,75 0,9 1,04 1,2 1,32 1,51 1,61 0,66 0,84 1,05 1,2 1,39 1,6 1,96 1,96 2,2N mot. kW 1,5 1,5 1,5 1,5 1,5 1,5 2,2 2,2 2,2 1,5 1,5 1,5 2,2 2,2 2,2 3 3 3
dB (A) with box 66 68 72 75 77 79 82 83 85 68 71 74 77 78 80 83 83 84without box 63 63 63 64 64 64 64 65 65 63 63 64 64 64 64 65 85 65
Q1 m3.h-1 56 83 118 148 182 212 242 259 278 77 120 168 213 261 299 365 365 388Δt °C 38 33 29 27 26 25 25 25 24 36 31 28 36 25 25 24 24 24rpm roots 1500 1900 2419 2860 3365 3810 4246 4505 4777 1428 1985 2410 2895 3400 3815 4523 4523 4780rpm mot. 2850 2850 2850 2860 2860 2895 2895 2895 2895 2850 2850 2860 2895 2860 2860 2895 2895 2895
200 kW N abs kW 0,74 0,93 1,25 1,5 1,7 1,9 2,15 2,33 2,54 0,98 1,3 1,59 1,93 2,29 2,54 3,13 3,13 3,37N mot. kW 1,5 1,5 1,5 2,2 2,2 3 3 3 3 1,5 2,2 2,2 3 3 3 4 4 4
dB (A) with box 66 68 72 75 77 79 82 84 85 68 71 75 78 79 80 84 84 85without box 63 63 64 64 64 64 64 65 65 63 63 64 64 64 64 65 65 65
Q1 m3.h-1 47 69 104 136 170 192 227 245 258 108 150 196 244 286 350 350 364Δt °C 82 67 57 52 49 47 45 45 44 60 53 49 47 45 43 43 43rpm roots 1585 1900 2430 2895 3400 3730 42,46 45,03 4701 1950 2413 2895 3412 3860 4550 4550 4700rpm mot. 2850 2850 2860 2895 2895 2895 2895 2895 2895 2860 2860 2895 2895 2925 2925 2925 2925
300 kW N abs kW 1,1 1,31 1,71 2,02 2,34 2,58 3,02 3,274 3,48 1,81 2,26 2,7 3,14 3,56 4,39 4,39 4,58N mot. kW 1,5 2,2 2,2 3 3 3 4 4 5,5 2,2 3 4 4 5,5 5,5 5,5 5,5
dB (A) with box 70 72 77 80 82 85 86 86 72 75 78 79 80 85 85 85without box 63 63 63 64 64 64 67 67 63 64 64 64 64 65 65 65
Q1 m3.h-1 90 115 156 183 210 233 244 95 133 178 232 268 332 332 348Δt °C 102 2895 83 79 76 4 73 109 94 84 78 75 71 71 70rpm roots 2450 2895 3412 3810 4214 4550 4710 2000 2413 2895 3473 3863 4558 4558 4718rpm mot. 2895 2,5 2895 2895 2925 2925 2925 2860 2895 2895 2925 2925 2930 2930 2930
400 kW N abs kW 2,17 3 3 3,33 3,75 4,15 4,34 2,33 2,81 3,41 4,09 4,52 5,56 5,56 5,8N mot. kW 3 78 4 4 5,5 5,5 5,5 3 4 4 5,5 5,5 7,5 7,5 7,5
dB (A) with box 74 65 80 82 85 87 87 74 75 78 79 80 86 86 86without box 64 65 65 68 68 69 64 64 64 64 64 65 65 65
Q1 m3.h-1 141 178 202 225 236 170 221 259 322 322 337Δt °C 110 101 97 94 93 109 100 95 90 90 89rpm roots 3310 3850 4214 4550 4710 2925 3474 3870 4558 4558 4718rpm mot. 2895 2895 2895 2925 2925 2925 2925 2925 2930 2930 2930
450 kW N abs kW 3,14 3,65 4,07 4,47 4,67 3,77 4,45 4,93 6,04 6,04 6,3N mot. kW 4 5,5 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5
dB (A) with box 80 83 85 87 87 78 79 80 86 86 86without box 65 66 68 69 69 64 64 64 66 66 65
Q1 m3.h-1 219 228 310 321 327Δt °C 114 113 114 113 112rpm roots 4550 4710 4558 4657 4718rpm mot. 2925 2925 2930 2930 2930
500 kW N abs kW 4,95 5,1 6,66 6,89 7N mot. kW 7,5 7,5 11 11 11
dB (A) with box 86 87 86 86 85without box 67 69 66 66 65
Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at a distance of 1m : ± 2 dB (A)
Characteristics
40
Vacuum up to –500 mbar
Q1 : Inlet flow t1 = 2O°CΔt : Temperature increaseabs.P. : Absorbed powermot.P. : Motor power
(continued) RV 5 ROOTS
Specifications are subject to be changed without notice
Δp/mbar Size Type 30.30 / DN 80 31.20 / DN 100Q1 m3.h-1 138 187 247 306 369 425 478 510 544 190 269 355 436 505 600 650 709 739Δt °C 13 12 11 11 11 10 10 10 10 12 11 11 10 10 10 10 10 10rpm roots 1500 1900 2390 2860 3360 3815 4240 4500 4780 1428 1900 2413 2895 3310 3877 4170 4525 4700rpm mot. 2850 2850 2895 2860 2860 2895 2895 2895 2895 2855 2855 2855 2895 2895 2895 2895 2895 2895
100 kW N abs kW 0,8 1 1,27 1,5 1,78 1,99 2,37 2,55 2,76 0,87 1,16 1,51 1,93 2,26 2,75 3 3,3 3,54N mot. kW 1,5 1,5 2,2 2,2 2,2 3 3 3 4 1,5 1,5 3 3 3 4 4 4 5,5
dB (A) with box 73 76 78 79 81 82 84 86 86 69 71 77 78 80 82 85 87 87without box 64 65 65 65 66 66 67 67 67 64 64 65 65 66 68 68 69 69
Q1 m3.h-1 117 163 226 286 335 400 449 491 511 164 248 329 410 481 572 634 675 712Δt °C 34 30 28 26 25 25 24 24 24 31 27 26 25 24 24 23 23 23rpm roots 1530 1907 2413 2895 3300 3810 4210 4550 4710 1430 1930 2413 2895 3315 3854 4220 4470 4700rpm mot. 2895 2895 2895 2895 2895 2895 2925 2925 2925 2860 2895 2895 2895 2925 2925 2930 2930 2930
200 kW N abs kW 1,4 1,65 2,07 2,5 2,84 3,26 3,87 4,31 4,53 1,57 2,12 2,59 2,5 3,83 4,57 5,36 5,8 6,4N mot. kW 2,2 2,2 3 3 4 4 5,5 5,5 5,5 2,2 3 4 3,21 5,5 5,5 7,5 7,5 7,5
dB (A) with box 74 76 78 80 82 83 85 88 88 70 72 78 4 82 84 86 87 88without box 65 65 65 66 67 67 67 68 68 64 64 65 66 66 68 68 69 70
Q1 m3.h-1 93 140 203 267 316 383 427 470 490 157 222 305 392 460 550 606 648 696Δt °C 73 61 53 49 47 45 44 43 43 58 52 47 45 44 42 42 41 41rpm roots 1524 1905 2413 2925 3320 3860 4217 4550 4720 1520 1911 2410 2925 3330 3861 4200 4455 4740rpm mot. 2895 2895 2895 2925 2925 2925 2930 2930 2930 2895 2895 2895 2925 2930 2930 2940 2940 2940
300 kW N abs kW 1,85 2,3 2,91 3,55 4,04 4,63 5,37 5,98 6,28 2,36 2,96 3,73 4,62 5,39 6,49 7,48 8,11 8,85N mot. kW 3 3 4 5,5 5,5 5,5 7,5 7,5 7,5 3 4 5,5 5,5 7,5 7,5 11 11 11
dB (A) with box 75 77 78 80 83 84 85 87 87 71 73 77 80 82 85 87 88 89without box 65 65 66 66 66 67 68 69 69 64 64 65 67 68 69 70 70 71
Q1 m3.h-1 129 179 243 293 360 401 437 468 148 205 282 368 436 511 582 625 671Δt °C 108 93 83 79 74 72 71 70 102 89 80 74 72 69 68 67 66rpm roots 2010 2410 2925 3330 3870 4200 4485 4735 1600 1959 2413 2930 3330 3780 4200 4455 4734rpm mot. 2895 2925 2925 2930 2930 2930 2930 2930 3,23 2895 2895 2930 2940 2940 2940 2940 2940
400 kW N abs kW 3,13 3,72 4,5 5,94 5,94 6,78 7,4 7,95 4 3,92 4,88 6,02 6,91 7,97 9,45 10,19 11,06N mot. kW 4 5,5 5,5 7,5 7,5 11 11 11 5,5 7,5 7,5 11 11 11 15 15
dB (A) with box 77 78 81 83 85 87 88 88 73 77 80 82 86 89 89 90without box 66 66 67 67 68 69 70 70 64 65 67 68 70 70 71 72
Q1 m3.h-1 230 280 346 388 418 455 268 357 423 499 569 611 658Δt °C 108 101 95 92 90 88 103 95 91 87 85 84 78rpm roots 2930 3330 3861 4200 4430 4734 2413 2940 3330 3790 4200 4455 4734rpm mot. 2930 2930 2930 2940 2940 2940 2930 2940 2940 2940 2940 2940 2940
450 kW N abs kW 4,95 5,65 6,51 7,42 7,95 8,62 5,43 6,6 7,6 8,83 10,27 11,06 11,94N mot. kW 7,5 7,5 7,5 11 11 11 7,5 11 11 11 15 15 15
dB (A) with box 84 86 88 90 90 80 82 86 89 90 91without box 68 69 70 72 72 67 68 70 71 72 72
Q1 m3.h-1 408 439 411 486 552 594 642Δt °C 114 112 114 110 106 105 103rpm roots 4473 4734 3330 3790 4200 4455 4734rpm mot. 2940 2940 2940 2940 2940 2940 2940
500 kW N abs kW 8,91 9,53 8,53 9,7 11,37 12,35 13,23N mot. kW 11 11 11 15 15 15 18,5
dB (A) with box 90 90 85 86 87 90 91without box 72 72 69 69 70 72 72
Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at a distance of 1m : ± 2 dB (A)
Characteristics
Vacuum up to –500 mbar
Q1 : Inlet flow t1 = 2O°CΔt : Temperature increaseabs.P. : Absorbed powermot.P. : Motor power
Characteristics
Specifications are subject to be changed without notice
Δp/mbar Size Type 31.30 / DN 100 32.20 / DN 100Q1 m3.h-1 290 408 534 654 761 864 952 1039 1106 449 589 775 918 1053 1184 1320Δt °C 11 11 10 10 10 10 10 10 10 11 10 10 10 10 10 10rpm roots 1430 1900 2413 2895 3330 3740 4100 4450 4720 1524 1939 2410 2925 3320 3710 4110rpm mot. 2860 2895 2895 2895 2895 2925 2925 2930 2930 2895 2895 2925 2925 2925 2930 2940
100 kW N abs kW 1,31 1,74 2,24 2,9 3,37 4,21 4,7 5,51 6,23 1,91 2,6 3,49 4,7 5,5 5,77 6,54N mot. kW 2,2 3 3 4 4 5,5 5,5 7,5 7,5 3 4 5,5 5,5 7,5 7,5 11
dB (A) with box 72 74 77 80 82 85 88 89 90 74 74 76 77 81 81 83without box 64 64 64 66 66 67 68 68 68 68 68 68 69 69 69 70
Q1 m3.h-1 280 375 500 629 750 828 945 1016 1078 371 564 716 894 1017 1157 1289Δt °C 28 26 25 24 24 23 23 23 23 26 24 24 23 23 23 22rpm roots 1520 1900 2400 2930 3330 3724 4200 4485 474 1529 1959 2413 2940 3310 3724 4110rpm mot. 2895 2895 2925 2930 2930 2940 2940 2940 2940 2895 2926 2895 2940 2940 2940 2940
200 kW N abs kW 2,44 3,05 3,93 4,92 5,86 6,83 7,96 8,7 9,4 1,53 4,47 5,78 7,42 8,5 9,86 11,43N mot. kW 3 4 5,5 7,5 7,5 11 11 11 11 4 5,5 7,5 11 11 15 15
dB (A) with box 73 74 77 81 83 85 88 90 91 75 75 76 78 82 82 84without box 64 64 64 66 66 67 68 69 69 68 68 69 69 69 70 70
Q1 m3.h-1 358 470 602 699 796 914 985 1047 536 709 864 988 1127 1260Δt °C 49 46 43 42 42 41 41 40 44 42 41 40 40 39rpm roots 1950 2413 2940 3330 3724 4200 4485 4740 1962 2476 2940 3310 3724 4110rpm mot. 2925 2930 2940 2940 2940 2940 2940 2940 2895 2940 2940 2940 2940 2940
300 kW N abs kW 4,46 5,53 7,01 8,17 9,47 11,03 12,04 13 6,34 8,24 10,01 11,62 13,64 15,76N mot. kW 5,5 7,5 11 11 11 15 15 18,5 7,5 11 15 15 18,5 18,5
dB (A) with box 75 78 82 84 86 89 91 91 75 77 78 83 84 87without box 64 65 66 67 68 70 71 71 69 69 69 69 70 70
Q1 m3.h-1 327 454 570 667 764 882 954 1015 480 678 834 958 1098 1222Δt °C 83 75 71 69 67 66 65 65 74 68 66 65 64 63rpm roots 1960 2470 2940 3330 3724 4200 4485 4740 1900 2476 2940 3310 3724 4100rpm mot. 2930 2930 2940 2940 2940 2940 2940 2940 2940 2940 2940 2940 2940 2940
400 kW N abs kW 5,84 7,41 9 10,47 12,07 13,94 15,14 16,2 7,78 10,53 12,8 14,7 17,22 19,56N mot. kW 7,5 11 11 15 15 18,5 18,5 18,5 11 15 15 18,5 22 30
dB (A) with box 76 80 84 86 88 91 93 94 76 78 81 84 84 88without box 65 66 68 68 70 72 72 73 69 69 70 70 71 71
Q1 m3.h-1 310 437 553 650 747 865 936 998 464 661 816 941 1080 1206Δt °C 108 96 90 87 85 83 81 81 94 86 83 81 79 79rpm roots 1960 2470 2940 3330 3724 4200 4485 4740 1900 2476 2940 3310 3724 4100rpm mot. 2930 2930 2940 2940 2940 2940 2940 2940 2940 2940 2940 2940 2940 2950
450 kW N abs kW 6,47 8,2 9,91 11,56 13,12 15,1 16,37 17,5 8,63 11,57 15,87 15,87 18,6 21N mot. kW 7,5 11 15 15 18,5 18,5 18,5 22 11 15 18,5 18,5 22 30
dB (A) with box 78 82 85 87 90 94 95 95 78 79 82 84 85 86without box 65 66 68 68 71 73 74 74 69 70 70 71 71 72
Q1 m3.h-1 546 630 729 846 918 979 633 798 921 1062Δt °C 114 110 106 103 101 100 109 103 101 98rpm roots 2940 3330 3724 4200 4485 4740 2476 2940 3310 3724rpm mot. 2940 2940 2940 2940 2940 2940 2940 2940 2940 2940
500 kW N abs kW 11,2 12,82 14,81 16,77 18,2 19,44 12,63 15,59 17,6 22,66N mot. kW 15 15 18,5 22 22 22 15 18,5 22 30
dB (A) with box 86 88 90 91 93 94 83 84 84 89without box 66 70 71 72 72 73 69 70 70 71
Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at a distance of 1m : ± 2 dB (A)
Characteristics
VACU
UM
pumps
41
42
Specifications are subject to be changed without notice
Vacuum up to –500 mbar
Q1 : Inlet flow t1 = 2O°CΔt : Temperature increaseabs.P. : Absorbed powermot.P. : Motor power
Δp/mbar Size Type 32.20/DN 150 32.30 / DN 150Q1 m3.h-1 1410 1518 600 818 1056 1307 1476 1686 1874 2004 2100Δt °C 10 10 11 10 10 10 10 10 10 10 10rpm roots 4390 4710 1450 1905 2410 2930 3282 3724 4116 4390 4600rpm mot. 2940 2940 2895 2895 2925 2930 2930 2940 2940 2940 2940
100 kW N abs kW 7,1 7,7 2,43 3,2 4,3 5,5 6,5 7,48 8,38 9,02 9,5N mot. kW 11 211 3 4 5,5 7,5 7,5 11 11 11 15
dB (A) with box 84 85 74 75 77 78 81 82 84 86 88without box 71 72 68 68 68 69 69 69 70 70 70
Q1 m3.h-1 1380 1488 798 1044 1266 1440 1641 1828 1959 2058Δt °C 22 22 25 24 23 23 23 22 22 22rpm roots 4390 4710 1962 2476 2940 3310 3724 4116 4390 4600rpm mot. 2940 2940 2925 2940 2940 2940 2940 2940 2940 2940
200 kW N abs kW 12,2 13,1 5,93 7,74 10,4 11,13 12,6 14,97 16,13 17N mot. kW 15 18,5 7,5 11 15 15 15 18,5 18,5 22
dB (A) with box 85 86 75 77 79 81 83 84 87 88without box 71 72 68 69 69 69 70 70 71 71
Q1 m3.h-1 1351 1458 774 1011 1224 1400 1596 1794 1920 2036Δt °C 39 39 44 42 41 40 40 39 39 39rpm roots 4390 4710 1995 2494 2940 3310 3724 4130 4405 4640rpm mot. 2940 2940 2940 2940 2940 2940 2940 2950 2950 2950
300 kW N abs kW 16,4 17,2 8,66 11 13,2 15,29 18,3 20,9 22,68 24,3N mot. kW 18,5 22 11 15 18,50 18,50 22 30 30 30
dB (A) with box 88 90 77 78 80 82 84 86 88 90without box 73 75 68 69 69 70 71 71 72 72
Q1 m3.h-1 1326 1428 728 966 1176 1353 1536 1746 1879 1992Δt °C 62 62 73 69 66 65 64 63 62 62rpm roots 4400 4720 1995 2494 2940 3305 3690 4130 4405 4640rpm mot. 2950 2950 2940 2940 2940 2950 2950 2950 2950 2950
400 kW N abs kW 20,6 21,5 11,3 14,3 17,1 19,7 23,1 26,35 28,53 30,46N mot. kW 30 30 15 18,5 22 30 30 30 37 37
dB (A) with box 89 91 78 79 81 83 85 87 89 91without box 73 76 69 70 70 71 72 72 72 73
Q1 m3.h-1 1260 1416 702 942 1155 1329 1512 1722 1854 1968Δt °C 77 77 93 86 83 81 80 78 78 77rpm roots 4400 4720 1995 2494 2940 3305 3690 4130 4405 4640rpm mot. 2950 2950 2940 2940 2940 2950 2950 2950 2950 2950
450 kW N abs kW 20,6 21,5 12,5 15,9 18,92 21,6 25,11 28,7 31 33N mot. kW 30 30 15 18,5 22 30 30 37 37 37
dB (A) with box 89 91 79 80 82 84 86 88 90 91without box 73 76 69 70 70 71 72 72 72 73
Q1 m3.h-1 1191 1281 918 1137 1299 1488 1698 1824 1944Δt °C 97 96 109 104 101 99 97 96 95rpm roots 4100 4400 2494 2940 3305 3690 4130 4405 4640rpm mot. 2940 2940 2940 2940 2940 2950 2950 2950 2950
500 kW N abs kW 23,48 24,59 17,72 21,21 23,89 27,94 31,80 34,33 36,73N mot. kW 30 30 22 30 30 37 37 45 45
dB (A) with box 90 90 82 84 84 86 90 90 91without box 70 71 70 71 71 71 72 72 73
Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at a distance of 1m : ± 2 dB (A)
Characteristics
RV 5 ROOTS(continued)
Characteristics
Specifications are subject to be changed without notice
General informations
The rotary piston compressors for vacuumwith pre-inlet and direct atmospheric com-pression, are capable of operating withvacuum pressure differences of up to –800mbar (200 mbar absolute pressure) in a singlestage, working continuously with no thermaloverloads and requiring no additionalmechanical fitting such as valves, regulators,pressure changeover gear, nor cooling system.
Operating principles
A volumetric displacement cycle ends whengas is compressed and the blower compres-sion chamber opens towards the delivery.The system consists in filling with fresh gasthe compression chamber before the pistonhead opens towards the delivery, the freshgas penetrating through the supplementarychannel, eliminating the heat or compressiontemperature at the very moment of its for-mation and expelling by rotation throughthe outlet or delivery.
The cooling gas in a single stage (compressionfrom atmosphere) is taken directly from theatmosphere (fig 1). If necessary to recover orre-compress the pumped gas, the coolinggas must be taken in from a gas coolerarranged in series connection (fig 2).
Technical specifications
The set is manufactured in 8 different sizes,with capacity ranging from 280 to 10 000m3/h. The vacuum pressure differences,depending on the blower speed, can reach upto –800 mbar (200 mbar absolute pressure).
The Roots pumps are of positive displacementtype and as such offer a wide range of pos-sibilities with regards to the intake flowrates, depending on the speed of rotationand the difference in pressure.
The operating performances tables shown inthis catalogue indicates operating guidelineaccording the pulley diameter ratios.Where flow rates and pressure are differentfrom those shown in the table, pleasecontact us.
fig. 2fig. 1
ROOTS vacuum pumps with pre-inlet
Lobe vacuum pumps Roots typeRV 8
VACU
UM
pumps
43
44
RV 8 ROOTSend vacuum : -800 mbar
Weight KgDN Motor Dimensions expressed in mm Fan Without Box
kW a b b’ c d e1 e e2 f g h j k l m n r s u v w kW motor30.20 80 11/160 940 148 258 625 88,9 195 455 170 746 578 650 300 187 1104 374 950 1200 1150 520 935 404 0,55 260 15031.20 100 18,5/160 1208 172 282 685 114,3 230 640 200 827 785 870 330 240 1325 409 1200 1370 1330 520 1049 488 0,75 410 20032.20 100 45/225 1251 172 282 685 114,3 230 640 200 827 785 870 330 240 1325 409 1200 1370 1330 520 1092 488 0,75 525 20033.20 150 75/280 1400 232 352 895 168,3 257 745 230 1040 900 1002 458 275 1665 460 1460 1650 1620 658 1320 614 0,75 840 550
• Oil-less compression• High output• Low noise level• Flow rates from 60 to 2200 m3.h-1
• ATEX version : on request
Specifications are subject to be changed without notice
Dimensions
1. Protection filter with adjusting pipefor relief valve
2. Pump RNPT type3. Base frame and silencer4. Rubber sleeve5. Non-return valve6. Relief valve7. Drive guard
8. Electric motor9. Rubber feet10. Connecting pipe with flange11. Electric fan*12. Soundproof box*13. Exhaust silencer*14. Pre-inlet silencer* On option
45
VACU
UM
pumps
Characteristics
Vacuum up to –500 mbar
Q1 : Inlet flow t1 = 2O°CΔt : Temperature increaseabs.P. : Absorbed powermot.P. : Motor power
Lobe vacuum pumps Roots type
Specifications are subject to be changed without notice
Δp/mbar Size Type 30.20 / DN 80 31.20 / DN 100Q1 m3.h-1 110 146 160 190 215 277 284 314 193 222 313 342 400 484 537 627Δt °C 71 67 66 64 62 60 61 60 66 64 60 59 58 57 57 56rpm roots 2388 2780 2925 3250 3510 4180 4395 4725 2050 2224 2770 2915 3286 3780 4200 4734rpm mot. 2895 2910 2925 2925 2930 2930 2930 2930 2910 2910 2915 2915 2915 2915 2910 2910
500 kW N abs kW 3,46 4 4,2 4,65 5 5,92 6,44 7,03 5,11 5,55 6,9 7,33 8,3 9,7 11,44 13,3N mot. kW 4 5,5 5,5 5,5 7,5 7,5 7,5 11 7,5 7,5 11 11 11 15 15 18,5
dB (A) with box 68 71 74 77 78 80 81 89 71 73 77 80 82 85 87 88without box 63 63 64 64 64 64 64 65 64 64 65 67 68 69 70 70
Q1 m3.h-1 64 99 118 118 148 172 236 254 285 136 166 256 285 342 426 497 587Δt °C 101 93 91 91 87 85 81 80 78 90 87 81 80 77 75 74 72rpm roots 2350 2730 2930 2930 3256 3515 4200 4390 4725 2050 2230 2767 2915 3286 3780 4200 4734rpm mot. 2895 2910 2930 2930 2930 2930 2910 2910 2910 2910 2915 2915 2915 2925 2925 2925 2940
600 kW N abs kW 4 4,57 4,9 4,9 5,46 5,94 7,04 7,54 8,22 6 6,54 8,2 8,73 9,9 11,4 13,4 15,5N mot. kW 5,5 5,5 7,5 7,5 7,5 7,5 11 11 11 7,5 11 11 11 15 15 18,5 18,5
dB (A) with box 68 71 75 75 78 79 80 82 84 71 73 77 80 82 86 89 89without box 63 63 64 64 64 64 64 64 65 64 64 65 67 68 70 70 71
Q1 m3.h-1 118 185 211 242 96 187 216 274 358 439Δt °C 11 107 105 103 110 107 105 102 99 96rpm roots 3460 4200 4390 4725 2230 2767 2925 3286 3780 4200rpm mot. 2910 2910 2910 2910 2915 2915 2925 2925 2930 2930
700 kW N abs kW 6,67 8,16 8,66 9,42 7,6 8,5 10,1 11,3 13,2 15,33N mot. kW 11 11 11 11 11 11 15 15 18,5 18,5
dB (A) with box 79 80 82 85 74 77 80 82 86 89without box 64 64 64 65 65 65 67 68 70 71
Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at a distance of 1m : ± 2 dB (A)
46
Specifications are subject to be changed without notice
Vacuum up to –500 mbar to -800 mbar
Q1 : Inlet flow t1 = 2O°CΔt : Temperature increaseabs.p. : Absorbed powermot.p. : Motor power
RV 8 ROOTS(continued)
Δp/mbar Size Type 32.20 / DN 100 33.20 / DN 150Q1 m3.h-1 300 560 744 798 912 996 1176 1374 680 930 1074 1290 1482 1698 1902 2172Δt °C 62 56 54 54 53 53 53 52 58 56 55 54 53 52 52 52rpm roots 1460 2231 2785 2940 3286 3528 4130 4720 1460 1825 2035 2360 2634 2950 3305 3710rpm mot. 2910 2925 2930 2940 2940 2940 2940 2940 2930 2940 2950 2950 2950 2950 2950 2965
500 kW N abs kW 7,36 11,4 14,7 15,6 17,5 18,8 23,6 26 14,8 18,6 20,8 24,1 27 30 37,5 43,9N mot. kW 11 15 18,5 18,5 22 22 30 30 18,5 22 30 30 37 37 45 55
dB (A) with box 75 75 77 78 83 84 87 89 78 80 82 85 86 87 88 89without box 68 68 69 69 69 70 70 71 68 68 69 69 69 70 70 71
Q1 m3.h-1 230 490 678 726 840 906 1127 1326 562 876 954 1176 1362 1584 1830 2100Δt °C 83 74 71 71 70 69 68 67 78 73 72 70 69 69 67 67rpm roots 1460 2234 2785 2940 3278 3470 4130 4720 1460 1930 2035 2360 2634 2960 3320 3713rpm mot. 2910 2930 2930 2940 2950 2950 2950 2950 2940 2950 2950 2950 2950 2950 2950 2960
600 kW N abs kW 8,65 13,6 17,2 18,1 20,6 21,9 27,4 30,5 17,8 23,3 24,8 28,5 31,9 35 44 50,9N mot. kW 11 18,5 22 22 30 30 37 37 22 30 30 37 37 45 55 75
dB (A) with box 75 76 78 81 84 84 88 88 79 81 83 86 87 88 89 90without box 68 69 69 70 70 71 71 72 68 68 69 69 69 70 71 72
Q1 m3.h-1 145 404 573 642 756 822 1056 1260 420 742 816 1002 1182 1440 1710 1976Δt °C 110 97 93 92 90 90 88 86 101 95 94 91 90 88 86 86rpm roots 1460 2234 2735 2950 3278 3470 4130 4736 1465 1935 2042 2315 2600 2950 3325 3713rpm mot. 2910 2930 2945 2950 2950 2950 2950 2950 2950 2950 2950 2950 2950 2950 2950 2960
700 kW N abs kW 10,2 15,6 19,5 21,2 23,6 25 31,3 35 20,4 27 28,4 32,3 36,2 40,6 50,4 57,8N mot. kW 15 18,5 30 30 30 30 37 45 30 37 37 37 45 45 75 75
dB (A) with box 77 78 79 82 85 86 87 89 80 82 84 87 88 89 90 91without box 68 69 70 70 71 72 72 73 68 69 69 69 70 70 71 72
Q1 m3.h-1 714 900 1152 1392 1650Δt °C 119 115 115 115 114rpm roots 2321 2600 2950 3325 3713rpm mot. 2950 2950 2950 2960 2960
800 kW N abs kW 36,6 41,2 46 56,8 65N mot. kW 45 55 55 75 75
dB (A) with box 88 89 89 91 91without box 70 70 71 71 72
Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at a distance of 1m : ± 2 dB (A)
Characteristics
Characteristics
47
VACU
UM
pumps
Specifications are subject to be changed without notice
RV 5 pump references
RV 5 and RV 8 ROOTS
30.20 31.20 32.20 33.20
Vacuum compact group (without motor) 411056 411057 411058 411059
4 kW 5,5 kW 7,5 kW 11 kW 15 kW 18,5 kW 22 kW
3-ph motor 400V Δ - 50 Hz - 3000 rpm 411032 411033 411034 411035 411036 411037 411038
30 kW 37 kW 45 kW 55 kW 75 kW
411039 411040 411041 411042 411043
30.20 31.20 32.20 33.20
Soundproofing hood 411060 411061 411062
Additionnal silencer 411046 411047 411048
Air-free and isolating pneumatic valves 716789 716790 716791
and control fitted on T-square
Star/delta starting box 5,5 kW 7,5 kW 11 kW 15 kW 18,5 kW 22 kW
716056 716057 716058 716059 716060 716061
Rinsing timer 616062
Temperature control 616064
Other capacities and pressures on request
Accessories
30.10 30.20 30.30 31.20 31.30 32.20 32.30
Vacuum compact group (without motor) 411007 411008 411009 411010 411011 411012 411013
1,5 kW 2,2 kW 3 kW 4 kW 5,5 kW 7,5 kW 11 kW
3-ph motor 400V Δ - 50 Hz - 3000 rpm 411029 411030 411031 411032 411033 411034 411035
15 kW 18,5 kW 22 kW 30 kW 37 kW
411036 411037 411038 411039 411040
30.10 30.20 30.30 31.20 31.30 32.20 32.30
Soundproofing hood 411014 411015 411016 411017
Additionnal silencer 411045 411046 411047 411048
Air-free and isolating pneumatic valves 716788 716789 716790 716791
and control fitted on T-square
Isolating manual valve 361304 360467 361351 361348
Star/delta starting box 5,5 kW 7,5 kW 11 kW 15 kW 18,5 kW 22 kW
716056 716057 716058 716059 716060 716061
Rinsing timer 616062
Temperature control 616064
Other capacities and pressures on request
Accessory and option references
RV8 pump references
Accessory and option references
48
BOOSTER
Applications
The BOOSTERS have a wide range of applica-tions in the field of vacuum. They are prefe-rably used in combination with a primaryvacuum pump (rotary vane vacuum pumps,etc…) and have a very extensive applicationin the field of low vacuum.
The use of BOOSTERS, forming a group withprimary pumps, being especially recommendedwhere high pumping speeds at low pressureare required.
ATEX version on request
Operating principles
During rotation, a progressively growingspace is created which corresponds to thesuction stage : phase 1 and 2, being graduallydecreased phase 3 and 4, compressing thevolume of gas. This cycle is repeated fourtimes per each complete rotation of thedrive shaft.
Characteristics of RB21.20BPand RB22.20 BP version
The built-in valve of by-pass is an unloadingvalve which allows communication betweeninlet and outlet of the BOOSTER when theacceptable maximum differential pressure isexceeded.A part of the gas flow is then recycled andthe electric motor does not have an overload.The device allows simultaneously the BOOSTERand the primary pump starts-up at theatmospheric pressure and to reduce the timeof pumping.This system puts also the BOOSTER safe fromaccidental gone up of pressure. Those pumpsare provided for a vertical operation.
The BOOSTERS belong to the group of positive displacement delivery pumps. Two symmetrical pistons having en eight feature, housed in thepump body, rotate in opposite directions with no contact neither between each other nor with the pump body, meshing continuously.The pistons are driven by a set of gears with synchronised rotation, which guarantees friction-free movement.
General details on the BOOSTERS
Type B pump references
�RB 20.10 �RB 20.20 �RB 21.20 �RB 21.20 BP* �RB 22.20 �RB 22.20 BP* �RB 22.30 �RB 23.20 �RB 23.20 BP* �RB 23.30411000 411001 411002 411052 411003 411053 411004 411005 411054 411006
* with integrated by-pass
20.10 20.20 21.20 21.20BP 22.20 22.20BP 22.30 23.20 23.20BP 23.30Rated suction flow m3.h-1 200 280 500 500 1000 1000 1430 2000 2000 2880Rotation speed rpm 2850 2850 2860 2860 2895 2895 2895 2910 2510 2910Maximum pressure difference mbar 130 80 80 80 66 50 40while continuous operationNominal motor power kW 0,75 1,1 2,2 2,2 4 4 4 5,5 5,5 7,5Normal supply voltage 50 Hz V 230/400 400ΔOil capacity in oil box A/B L 0,7/1,0 0,7/1,0 1,1/1,6 1,1/1,6 1,6/2,5 1,6/2,5 1,6/2,5 3,1/4,8 3,1/4,8 3,1/4,8Oil capacity L 0,06 0,06 0,07 0,07 0,08 0,08 0,08 0,1 0,1 0,1shaft passage sealPump weight with motor kg 73 85 130 130 240 240 270 360 360 400Pump weight (free shaft) kg 62 76 115 115 208 208 245 320 320 360
Specifications are subject to be changed without notice
Characteristics
49
BOOSTER RB typeThe RB pumps are used in combination with primary vacuum pumps.
Construction characteristicsThe BOOSTERS drive shaft is directly driven by the motor shaft by means of an elastic coupling. The shaft passageis closed off by seals with oil. A cooling chamber is included for the shaft passage to eliminate the heat producedby the seal. All the seals are made of VITON elastomer. The RB type is supplied with an AC three-phase motor.The BOOSTERS can be supplied with free drive shaft.
VACU
UM
pumps
aDN a1
a4a5
v
a3a2
DN
BP (=BY-PASS)
KL
b2b3b1
d1
h2
h
s
J
B Type (standard)
A Type (option)
Rotary piston vacuum pumpsRoots type
Specifications are subject to be changed without notice
Type DN a a1 a2 a3 a4 a5 a6 b1 b2 b3 BP c c1 c2 c320.10 50 746 220 148 118 12 74 470 313 193 253 276 240 120 18020.20 80 786 240 188 158 52 94 510 313 193 253 276 240 120 18021.20 100 949 290 270 230 116 135 614 360 220 290 320 275 135 20521.20 BP 100 932 292 270 230 120 135 614 360 220 290 38022.20 100 1126 342 326 282 150 163 728 434 274 354 350 320 160 24022.20 BP 100 1126 342 326 282 150 163 728 434 274 354 46022.30 150 1238 398 438 394 262 219 840 434 274 354 350 320 160 240023.20 150 1288 396 412 362 222 206 830 534 354 444 400 390 210 30023.20 BP 150 1288 396 412 362 222 206 830 534 354 444 59023.30 150 1428 466 552 502 262 276 970 534 354 444 400 390 210 300
J Shaft’s endType d1 h h1 h2 h3 s v K L Ø Qty d I d6 u t20.10 14 276 304 138 175 18 18 165 125 18 4 20k6 45 M-6 6 22,620.20 14 276 304 138 175 18 18 200 160 18 4 20k6 45 M-6 6 22,621.20 18 320 350 160 203 20 20 220 180 18 8 28k6 53 M-8 8 3121.20 BP 18 320 160 20 23 220 180 18 4 28k6 53 M-8 8 3122.20 18 350 414 175 232 20 23 220 180 18 8 32k6 68 M-12 10 35,422.20 BP 18 350 175 20 23 220 180 18 32k6 68 M-12 10 35,422.30 18 350 414 175 232 22 23 285 240 23 8 32k6 68 M-12 10 35,423.20 24 400 492 200 272 22 25 285 240 23 8 38k6 68 M-12 10 41,423.20 BP 24 400 492 200 272 22 25 285 240 23 8 38k6 68 M-12 10 41,423.30 24 400 492 200 272 22 25 285 240 23 8 38k6 68 M-12 10 41,4
Dimensions
50
BOOSTER/EVISA
• Booster/EVISA coupling• PO suction filter
• Control board• Engagement switch
NOMINAL MOTOR MAXIMUM PRESSURE CONNECTION WEIGHTCAPACITY POWER DIFFERENCE WITH
BOOSTERm3.h-1 kW mbar kg
Booster EVISA Booster EVISA21.20 / E150 500 150 2,2 3,0 80 DN 100 26021.20 BP*/ E150 500 150 2,2 3,0 DN 100 27021.20 / E200 500 190 2,2 4,0 80 DN 100 28021.20 BP*/ E200 500 190 2,2 4,0 DN 100 29022.20 / E300 1000 288 4,0 5,5 80 DN 100 48022.20 BP*/ E300 1000 288 4,0 5,5 DN 100 50022.20 / E350 1000 360 4,0 7,5 80 DN 100 64022.20 BP*/ E350 1000 360 4,0 7,5 DN 100 65022.20 / E400 1000 426 4,0 9,0 80 DN 100 67022.20 BP*/ E400 1000 426 4,0 9,0 DN 100 68022.20 / E500 1000 513 4,0 11,0 80 DN 100 71022.20 BP*/ E500 1000 513 4,0 11,0 DN 100 72022.30 / E400 1430 426 4,0 9,0 66 DN 150 72022.30 / E500 1430 513 4,0 11,0 66 DN 150 76023.20 / E500 2000 513 5,5 11,0 50 DN 150 83023.20 BP*/ E500 2000 513 5,5 11,0 DN 150 840
* Integrated by-passPossibility of pumping from the atmospheric pressure with by-pass versionOther solutions of coupling : contact us
Characteristics
Standard configuration example
Specifications are subject to be changed without notice
Capacity - pressure curve (50 Hz)2000
1500
1000
500
100
10
2000
1500
1000
500
100
100,01 0,1 1 10 40 50 7080 100 1000 mbar abs
21.20/E150
21.20/E200
22.20/E300
22.20/E350
21.20BP/E150
21.20BP/E200
22.20BP/E300
22.20BP/E350
22.20/E400
22.20/E500
22.30/E400
22.30/E500
23.20/E500
22.20BP/E400
22.20BP/E150
23.20BP/E500
Flow
rate
(m3 .h
-1)
Absolute pressure
51
• Lubricated rotary vane vacuum pumps (EVISA) and booster• End vacuum : 5.10-2 up to 1.10-2 mbar abs• Skid assembly• Running and maintenance low costs• Control board as option• Available with by-pass version for high rate of work
VACU
UM
pumps
CH
I
ØA
E B
D DA
F
ØB
I
Ø Suction
Ø Exhaust
21.20 21.20 22.20 22.20 22.20 22.20 22.30 22.30 23.20
E150 E200 E300 E350 E400 E500 E400 E500 E500
Inlet filter with polyester filter element DN100 DN150
616805 617501
Control box with timer 716809 716403 716812 Contact us
Mechanical engagement switch 716813
Roots/EVISA vacuum pumppumping assembly
A B C D E F G H I Ø Ø ØA ØBSUCTION EXHAUST
21.20 / E150 949 670 812 550 620 110 239 1285 1507 DN 100 2” 15 1/4”21.20 / E200 955 670 812 550 620 128 227 1285 1507 DN 100 2” 15 1/4”22.20 / E300 1147 720 863 800 670 172 125 1336 1558 DN 100 2” 15 1/4”22.20 / E350 1300 720 952 800 670 217 232 1425 1647 DN 100 3” 15 1/4”22.20 / E400 1368 720 952 800 670 286 232 1425 1647 DN 100 3” 15 1/4”22.20 / E500 1416 720 952 800 670 321 245 1425 1647 DN 100 3” 15 1/4”22.30 / E400 1436 870 1018 1050 820 125 211 1567 1761 DN 150 3” 15 1/4”22.30 / E500 1483 870 1018 1050 820 160 223 1567 1761 DN 150 3” 15 1/4”23.20 / E500 1483 870 1068 1050 820 160 223 1617 1811 DN 150 3” 15 1/4”
BOOSTER / EVISA COUPLING 21.20 21.20 22.20 22.20 22.20 22.20 22.30 22.30 23.20
E150 E200 E300 E350 E400 E500 E400 E500 E500
Booster without by-pass 918500 918502 918505 918581 918582 918583 918514 918515 918982
Booster with by-pass 918983 918984 918985 918986 918987 918988 918989
Dimensions
Specifications are subject to be changed without notice
Pump references
Accessory and option references
Dimensions expressed in mm
52
ANTIGUA
Specifications are subject to be changed without notice
10 40 60 80 100 200 400 1000 mbar
S26 - 50HzS26 - 60HzS51 - 50HzS51 - 60Hz
S126 - 50Hz
S126 - 60Hz
S161 - 50Hz
S161 - 60Hz
S251 - 50Hz
S251 - 60HzS325 - 50Hz
S325 - 60Hz
m3.h-1
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0Absolute pressure
• Liquid ring vacuum pumps• Low water consumption• Capable of handling draw-in liquids and dust• Low maintenance
Characteristics
Capacity - pressure curve (50 Hz/60 Hz)Flow rate
NOMINAL CAPACITYm3.h-1
POWERkW
NOISELEVEL
WEIGHTkg
WATER CONSUMPTION*L/min
50 Hz 60 Hz 50 Hz 60 Hz dB(A) 50 Hz 60 Hz openedrange
withseparator
�ANTIGUA S26 27 37 0.75 1.1 68 21 21 4 2�ANTIGUA S51 49 58 1.5 2.2 68 27 30 4 2�ANTIGUA S126 89 110 3 4.8 67 51 56 8 4�ANTIGUA S161 152 198 4 6 65 82 110 16 8�ANTIGUA S251 230 280 5.5 8 65 120 125 16 8�ANTIGUA S325 290 360 7.5 13.2 70 145 185 20 12* consumption for a low pressure less than 200 mbar abs.
3Non return valve
2Suction hoses
1Water flowregulation
Air/waterseparator trap
4
Water supply
Liquid ring vacuum pumps
Specifications are subject to be changed without notice
VACU
UM
pumps
53
Dimensions
Accessory and option references
Liquid ring vacuum pump references
ANTIGUA S26 - S51 - S126 - S161 ANTIGUA S251 and S325
A = A1
A = A1
B1
B1
G
G
1/4”1/4”ØUb
ØUbØA
ØA
ØC
C1
CC
C1
ØC
EE
HH
J J
BD
B
D
K
K
F
F
WITHOUT SEPARATOR WITH SEPARATORA B C A1 B1 C1 D E F G H I J K Ø A Ø Ub Ø C
�ANTIGUA S26 338 182 210 338 200 460 125 100 70 88 20 43.5 80 68 9 1/4" 1"�ANTIGUA S51 366 182 229 366 205 470 140 100 74 109 20 44 90 81 9 1/4" 1"�ANTIGUA S126 424 250 280 424 320 650 160 140 110 95 5 33 100 138 12 1/4" 1"1/4�ANTIGUA S161 515 338 342 515 390 750 190 140 180 143 8 47 112 172 12 1/2" 1"1/2�ANTIGUA S251 599 365 365 599 405 880 216 140 200 159 15 90 132 195 12 1/2" DN50�ANTIGUA S325 704 425 412 704 540 1100 216 178 240 92 0 104 160 202 15 1” DN65Dimensions expressed in mm
�S26 �S51 �S126 �S161 �S251 �S32550Hz 819948 819949 819950 819951 819952 81995360Hz 819954 819955 819956 819957 819958 819959
�S26 �S51 �S126 �S161 �S251 �S325Inlet/outlet flange adaptor DN50 (2")
619965DN65 (2")619966
Water flow regulationwithout separator
4 l/min357038
8 l/min357039
16 l/min357042
20 l/min357043
with separator2 l/min357041
4 l/min357038
8 l/min357039
12 l/min357040
Liquid separator with hosefor a partial water recycling
1 619960 619961 619962 619963
Strainer on water inlet withsecurity pressure gauge *
without separator 621363 621364 619968 619970with separator 621362 621363 621364 621365
Suction and exhaust M/F hoses2
Ø25 x 1200715394
Ø35 x 1200712928
foreseen flange adaptatorØ45 x 1500712929
Inlet non-return valve3 719971 719972 719973LG7 device 818277 818278 818279Cavitation protection hose**
619974 619975foreseen flange adaptator
619976
AIR/WATER separator trap4 PS65707604
PS130707605
PS320707606
* Water flow regulation non included** Cavitation protection hose : only for end vacuum running and included with water flow regulation separator
54
MINIVAC 1
Specifications are subject to be changed without notice
• Compact and independent vacuum plant• Available with lubricated rotary vane vacuum pumps (EVISA MV),
oil-less rotary vane vacuum pumps (ARICA) or oil-less pistonvacuum pumps (PS)
• Regulation by mechanical 2 thresholds vacuum switch
For more details on EVISA pumps, please report to page 6
For more details on ARICA pumps, please report to page 26
For more details on PS pumps, please report to page 34
Suction filterwith paper or
polyester element
1
MINIVAC 1 EVISA NOMINAL POWER RECEIVER NOISE OIL WEIGHTLubricated rotary vane vacuum pumps CAPACITY CAPACITY LEVEL FILLING
m3.h-1 kW L dB (A) L kgTYPE 50 Hz 60 Hz 50 Hz 60 Hz�MINIVAC 1 E17 17 20 0,55 0,66 70 59 1,5 85�MINIVAC 1 E25 30 36 0,75 0,90 70 60 1,5 85�MINIVAC 1 E40 47 56 1,1 1,30 70 62 1,5 100
Maxi vacuum in network : 5 mbar abs. (-995 mbar relative) with version without regulation
MINIVAC 1 ARICA NOMINAL POWER RECEIVER NOISE WEIGHTOil-less rotary vane vacuum pumps CAPACITY CAPACITY LEVEL
m3.h-1 kW L dB (A) kgTYPE 50 Hz 60 Hz 50 Hz 60 Hz�MINIVAC 1 ARICA 3VK 4,0 4,8 0,25 0,30 70 58 30�MINIVAC 1 ARICA 6VK 7,0 8,4 0,30 0,36 70 59 36�MINIVAC 1 ARICA 10V 11,0 13,0 0,37 0,44 70 60 44�MINIVAC 1 ARICA 15V 17,5 21,0 0,55 0,66 70 63 53�MINIVAC 1 ARICA 25V 27,0 32,5 0,75 0,90 70 65 58
Maxi vacuum in network : 200 mbar abs. (-800 mbar relative) with version without regulation
MINIVAC 1 PS NOMINAL POWER RECEIVER NOISE WEIGHTDry piston vacuum pumps CAPACITY CAPACITY LEVEL
m3.h-1 kW L dB (A) kgTYPE 50 Hz 60 Hz 50 Hz 60 Hz�MINIVAC 1 PS 2V 2,8 3,4 0,20 0,24 70 57 30�MINIVAC 1 PS 5V 4,2 5,3 0,17 0,20 70 57 36�MINIVAC 1 PS 7V 6,4 7,6 0,25 0,30 70 57 36�MINIVAC 1 PS 12V 10,1 12,1 0,36 0,43 70 57 36�MINIVAC 1 PS 5VH 2,9 3,6 0,17 0,20 70 57 36�MINIVAC 1 PS 7VH 4,3 5,4 0,25 0,30 30 57 36�MINIVAC 1 PS 12VH 7,4 8,9 0,36 0,43 70 57 36
Maxi vacuum in network : 200 mbar abs. (-800 mbar relative) with PS vacuum pumps, V version
100 mbar abs. (-900 mbar relative) with PS vacuum pumps, VH version
Characteristics
MINIVAC 1 PS
VACU
UM
plants
55
Dimensions
A B
ØA
Specifications are subject to be changed without notice
D(w
ith
optio
nali
nlet
filte
r)
C(w
itho
utop
tiona
linl
etfil
ter)
female G1/2” 3xØ8 to 120° on Ø550
Plant references
Automatic vacuum plantsfor industrial applications
MINIVAC 1 on receiver A B C D ØA ØFE17 70 litres 650 705 705 785 1/2" 550E17 70 litres 650 705 725 785 3/4" 550E25 70 litres 650 705 725 785 3/4" 550E40 70 litres 650 705 725 785 1" 550ARICA 3VK 70 litres 650 705 565 585 1/2" 550ARICA 6VK 70 litres 650 705 585 615 1/2" 550ARICA 10V 70 litres 650 705 630 680 3/4" 550ARICA 15V 70 litres 650 705 675 760 3/4" 550ARICA 25V 70 litres 650 705 675 760 3/4" 550PS 2V 70 litres 650 705 660 680 1/2" 550PS 5V 70 litres 650 705 660 680 1/2" 550PS 7V 70 litres 650 705 660 680 1/2" 550PS 12V 70 litres 650 705 700 720 1/2" 550PS 5VH 70 litres 650 705 660 680 1/2" 550PS 7VH 70 litres 650 705 660 680 1/2" 550PS 12VH 70 litres 650 705 700 720 1/2" 550
�MINIVAC 1 �MINIVAC 1 �MINIVAC 1MINIVAC 1 EVISA E17 E25 E40
3-ph 400V+N+E 916763 916300 916766
1-ph 230V 916765 916767
�MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1MINIVAC 1 ARICA ARICA 3VK ARICA 6VK ARICA 10V ARICA 15V ARICA 25V
3-ph 400V+N+E 916771 916772 916773
1-ph 230V 916769 916770
�MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1MINIVAC 1 PS PS 2V PS 5V PS 7V PS 12V PS 5VH PS 7VH PS 12VH
1-ph 230V 970101 970273 914930 919059 916070 916071 919060
�MINIVAC 1 �MINIVAC 1 �MINIVAC 1MINIVAC 1 EVISA E17 E25 E40
Suction filter Paper 76PA 100PA
715347 714975Polyester 76PO 100PO
715348 714976Suction hose for network connection 712926 715394
�MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1MINIVAC 1 ARICA ARICA 3VK ARICA 6VK ARICA 10V ARICA 15V ARICA 25V
Suction filter Paper 25PA 51PA 51PA 76PA
714926 610502 357947 706190Suction hose for network connection 618981 712931 712926
�MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1 �MINIVAC 1MINIVAC 1 PS PS 2V PS 5V PS 7V PS 12V PS 5VH PS 7VH PS 12VHSuction filter 25PA : 358225 51 PA : 357947Suction hose for network connection 670177 618981
1
1
1
Accessory and option references
56
• Compact and independent vacuum plantfor centralized vacuum production
• Lubricated rotary vane vacuum pumpEVISA MV or HV type
• Electromechanical control board(mechanical 2 thresholds vacuum switch)electronic control board (MILLENIUM PLCwith transducer)
• Optional suction filter• Optional FLEXO regulation system
INDUSVAC 1
Ready for use and easy setting
1Suction hoses
3Bacterial filtration
2Suction filterwith paper or
polyester element
NORMAL POWER RECEIVER NOISE OIL WEIGHTCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L kg
50 Hz 60 Hz 50 Hz 60 Hz�INDUSVAC 1 E17 H3 17 20 0,55 0,66 300 59 1,5 85�INDUSVAC 1 E25 H3 30 36 0,75 0,90 300 60 1,5 85�INDUSVAC 1 E40 H3 47 56 1,10 1,30 300 62 1,5 110�INDUSVAC 1 E65 H3 65 78 1,50 1,80 300 65 4,0 145�INDUSVAC 1 E100 H3 96 115 2,20 2,64 300 67 4,0 210�INDUSVAC 1 E150 H5 150 180 3,00 3,60 500 70 7,0 260�INDUSVAC 1 E200 H5 190 228 4,00 4,80 500 71 7,0 280�INDUSVAC 1 E300 H5 288 345 5,50 6,60 500 73 7,0 380
Maxi vacuum in network : 5 mbar abs. (-995 mbar relative) with version without regulation
Characteristics
Specifications are subject to be changed without notice
Double filtration A B ØC ØD76PO/76CH 290 335 147 Female 3/4"100PO/100CH 320 380 147 Female 1"126PO/126CH 400 530 187 Female 1"1/4201PO/201CH 550 705 220 Female 2"
ØD
ØC
B
A
Dimensions
Double filtration
VACU
UM
plants
57
Dimensions (continued)
F
Plant references
4 openings Ø14 x 28
�E17 H3 �E25 H3 �E40 H3 �E65 H3 �E100 H3�E150 H5�E200 H5�E300 H5
FLEXO regulation system 670644 615415 670645 670646
M/F suction hoses Network connection Ø20x1000 Ø25x1200 Ø30x1200 Ø35x1200 Ø45x1500
712926 715394 712927 712928 712929Suction filter Paper 76PA 100PA 126PA 201PAmounted before 709505 715412 709507 709513receiver inlet Polyester 76PO 100PO 126PO 201PO
709506 715413 709508 709514Carbon 76CH 100CH 126CH 201CH
710520 715414 710521 710522
Simple bacterial filtration FD30S FD65S FD130S FD320Swithout by-pass 812060 812061 812062 812063
Double filtration 76PO/76CH 100PO/100CH 126PO/126CH 201PO/201CH
719832 719833 719834 719835
3
2
1
INDUSVAC 1 with vacuum switch�E17 H3 �E25 H3 �E40 H3 �E65 H3 �E100 H3 �E150 H5 �E200 H5 �E300 H5
A 1830 1830 1830 1880 1880 2150 2150 2150B 600 600 620 630 630 770 770 755C 1030 1030 1030 1135 1135 1290 1300 1360D 995 995 995 995 995 1200 1200 1200E 300 300 300 300 300 360 360 360F 3/4” 3/4” 1” 1”1/4 1”1/4 2” 2” 2”ØG 500 500 500 500 500 600 600 600H 660 660 675 750 750 860 860 860
Dimensions expressed in mm
Accessory and option references
Specifications are subject to be changed without notice
Automatic vacuum plantsfor industrial applications
INDUSVAC 1 MV �E17 H3 �E25 H3 �E40 H3 �E65 H3 �E100 H3�E150 H5�E200 H5�E300 H5with vacuum switch 3-ph 400V+N 916732 970421 970422 970423 970424 970425 970431 970432
1-ph 915580 916055with MILLENIUM 3-ph 400V+N 918959 918960 918961 918962 918963 918964 918965 918966
1-ph 918967 918968
INDUSVAC 1 HV �E17 H3 �E25 H3 �E40 H3 �E65 H3 �E100 H3�E150 H5�E200 H5�E300 H5with vacuum switch 3-ph 400V+N 921249 921250 921251 921252 921253 921254 921255 921256
1-ph 921257 921258with MILLENIUM 3-ph 400V+N 921259 921260 921261 921262 921263 921264 921265 921266
1-ph 921267 921268
58
• Compact and independent vacuum plantfor centralized vacuum production
• Safety of use with 2 vacuum pumpsEVISA MV or HV type
• Automatic permutation system• Electronic control board (MILLENIUM PLC
with transducer)• Optional suction filter• Optional FLEXO regulation system
INDUSVAC 2
Ready for use and easy setting
Characteristics
NORMAL POWER RECEIVER NOISE OIL WEIGHTCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L kg
50 Hz 60 Hz 50 Hz 60 Hz�INDUSVAC 2 E17 H5 2 x 17 2 x 20 2 x 0,55 2 x 0,66 500 62 2 x 1,5 160�INDUSVAC 2 E25 H5 2 x 30 2 x 36 2 x 0,75 2 x 0,90 500 63 2 x 1,5 160�INDUSVAC 2 E40 H5 2 x 47 2 x 56 2 x 1,10 2 x 1,30 500 65 2 x 1,5 200�INDUSVAC 2 E65 H5 2 x 65 2 x 78 2 x 1,50 2 x 1,80 500 68 2 x 4,0 280�INDUSVAC 2 E100 H5 2 x 96 2 x 115 2 x 2,20 2 x 2,64 500 70 2 x 4,0 300�INDUSVAC 2 E150 H8 2 x 150 2 x 180 2 x 3,00 2 x 3,60 800 73 2 x 7,0 385�INDUSVAC 2 E200 H8 2 x 190 2 x 228 2 x 4,00 2 x 4,80 800 74 2 x 7,0 425�INDUSVAC 2 E300 H8 2 x 288 2 x 345 2 x 5,50 2 x 6,60 800 76 2 x 7,0 620Maxi vacuum in network : 5 mbar abs. (-995 mbar relative) with version without regulation
Specifications are subject to be changed without notice
Double filtration A B ØC ØD126PO/126CH 400 530 187 Female 1"1/4201PO/201CH 550 705 220 Female 2"251PO/251CH 650 860 220 Female 2"1/2
ØD
ØC
B
A
Dimensions
Double filtration
INDUSVAC - Vertical assemblyexists in duplex
and triplex versionConsult us
VACU
UM
plants
59
Dimensions (continued)
Plant references
�E17 H5 �E25 H5 �E40 H5 �E65 H5 �E100 H5 �E150 H8 �E200 H8 �E300 H8A 2120 2120 2120 2120 2150 2605 2605 2660B 845 845 865 875 875 995 995 995B1 990 990 1010 1020 1020 1140 1140 1140C 1140 1140 1130 1235 1235 1400 1400 1460D 1200 1200 1200 1200 1200 1500 1500 1500E 360 360 360 360 360 400 400 400F 1”1/4 1”1/4 1”1/4 1”1/4 2” 2”1/2 2”1/2 2”1/2ØG 600 600 600 600 600 700 700 700H 800 800 800 800 860 1005 1005 1005
Dimensions expressed in mm
�E17 H5 �E25 H5 �E40 H5 �E65 H5 �E100 H5�E150 H8�E200 H8�E300 H8
FLEXO regulation system 613002 615432 613003 613004 613005M/F suction hoses Network connection Ø30x1200 Ø45x1500 Ø60x1500
712927 712929 770300Suction filter Paper 126PA 201PA 251PAmounted before 712977 709513 770623receiver inlet Polyester 126PO 201PO 251POsee page 12 712978 709514 770624
Carbon 126CH 201CH 251CH712979 712980 770625
Simple bacterial filtration FD30S FD65S FD130S FD320S Contactwithout by-pass 812060 812061 812062 812063 us
Double filtration 126PO/126CH 201PO/201CH 251PO/251CH
719834 719835 719836Specifications are subject to be changed without notice
Accessory and option references
Automatic vacuum plantsfor industrial applications
4 openingsØ14 x 28
�E17 H5 �E25 H5 �E40 H5 �E65 H5 �E100 H5�E150 H8�E200 H8�E300 H8
INDUSVAC 2 MILLENIUM - MV 3-ph 400V+N+E 916734 916735 916736 916737 916738 916739 916740 916741
INDUSVAC 2 MILLENIUM - HV 3-ph 400V+N+E 921269 921270 921271 921272 921273 921274 921275 921276
INDUSVAC 1 and 2 ATEX
60
Specifications are subject to be changed without notice
• Centralized vacuum system with 1 or 2 pumps• CE mark for explosive atmosphere :
II 2 G IIB T4 (INERIS Certificate - n°021731/09)• Lubricated vacuum pump EVISA type• PT100 with inbuilt security temperature sensor fitted
on each pump• Inlet filter on each pump• Pneumatic FLEXO valve fitted on each pump• Flame protection on tank inlet• Electrical box with inbuilt security, in ATEX area• Electrical control board with MILLENIUM PLC to be fitted
outside of ATEX area
Characteristics
Standard power supplies Pneumatic supply
Process sequence
NOMINAL CAPACITYper pumpm³.h-1
POWER
kW
RECEIVERCAPACITY
L
NOISELEVELdB(A)
WEIGHT
kg50 Hz 60 Hz 50 Hz 60 Hz 1 pump 2 pumps 1 pump 2 pumps
�INDUSVAC 1 or 2 E65 65 78 1.5 1.8 300 500 65 165 300�INDUSVAC 1 or 2 E100 96 115 2.2 2.64 300 500 67 175 320�INDUSVAC 1 or 2 E200 190 228 4 4.8 500 800 71 320 465�INDUSVAC 1 or 2 E300 288 345 5.5 6.6 500 800 73 395 650
PT100 Electricalcontrol board
Vacuum pump- filter -
pneumatic valve
FlameprotectionApplication
Receiver
Pneumaticcontrol signal
• 3-phase, 400V/50Hz or 460V/60Hz + Neutral• Other tensions on request
• Compressed air between 6 and 10 bar• Pneumatic supply• Quality class air : 2 4 3 complying with
ISO 8573-1 Standard
ATEX area Outside of ATEX area
Automatic vacuum plantsfor industrial applications
61
VACU
UM
plants
Specifications are subject to be changed without notice
Dimensions
Plant references
�E65 �E100 �E200 �E300INDUSVAC 1 ATEX 921244 921245 921280 921278INDUSVAC 2 ATEX 921239 921246 921277 921247
INDUSVAC ATEX 1�E65 �E100 �E200 �E300
A 1642 1642 1886 1886B 898 898 1053 1053C 1262 1262 1530 1530D 995 995 1200 1200E 300 300 360 360F 400 400 450 450G 528 528 628 628H 727 727 829 827I 1156 1156 1390 1349J 263 263 253 295K 408 408 386 387øL Suct. DN50 DN50 DN80 DN80øM Exh. G 1"1/4 G 1"1/4 G 2" G 2"
INDUSVAC ATEX 2�E65 �E100 �E200 �E300
A 1886 1886 2326 2326B 968 968 1027 1027C 1362 1362 1645 1645D 1200 1200 1500 1500E 360 360 400 400F 450 450 520 520G 568 568 678 678H 277 277 302 300I 1798 1798 2263 2263J # # # #K 421 421 552 554øL Suct. DN50 DN50 DN80 DN80øM Exh. DN50 DN50 DN80 DN80
I J
D
A
ØM
G
K
C
H
FØL
B
E 4 x Ø14
I
D
A
ØM
H
F
G
K
C
E
B4 x Ø14
ØL
Electrical control board
400
600
200
Dimensions expressed in mm
62
Static and mobileCOMPOSITVAC
Dimensions Accessories
• Static or mobile vacuum plants with 2 vacuum levels• Lubricated rotary vane vacuum pumps EVISA type• Running with vacuum switch for maxi vacuum and with control solenoid valve for regulated vacuum• Activated carbon filter for odours and aggressive vapours removal• Several outlets for maxi and regulated vacuum
Specifications are subject to be changed without notice
Characteristics
1680 780
1350
735 900
1055
Mobile COMPOSITVAC E65
Mobile COMPOSITVAC E25 1Equipped 80 litrereceiver to obtain
several vacuumlevels from an
existing centralizednetwork
3Degassing
vacuum chamber
Resin trap withsight porthole,
quick connectionand stain-less
steel bowl
2
2 X 2 valves with GEKA quick couplings
2 X 5 valves with GEKA quick couplings
Mobile COMPOSITVAC NOMINAL POWER RECEIVER NOISE OIL WEIGHTCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L kg
50 Hz 60 Hz 50 Hz 60 Hz�Mobile COMPOSITVAC E25 30 36 0,75 0,90 70 60 1,5 115�Mobile COMPOSITVAC E40 47 56 1,10 1,30 250 62 1,5 250�Mobile COMPOSITVAC E65 65 78 1,50 1,80 250 65 4,0 265
Static COMPOSITVAC NOMINAL POWER RECEIVER NOISE OIL WEIGHTCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L kg
50 Hz 60 Hz 50 Hz 60 Hz�Static COMPOSITVAC E65 65 78 1,50 1,80 500 + 80 65 4,0 260�Static COMPOSITVAC E100 96 115 2,20 2,64 500 + 80 67 4,0 280
VACU
UM
plants
63
Automatic vacuum plantsfor composites
Specifications are subject to be changed without notice
Dimensions (continued)
Plant references
1590 1080
1995
Static COMPOSITVAC2 X 5 valves 3/4”female
Mobile COMPOSITVAC �Mobile COMPOSITVAC E25 �Mobile COMPOSITVAC E40 �Mobile COMPOSITVAC E65
1-ph 230V 919758 919788
3-ph 400V+N+E 919760 919787 919763
3-ph 230V+E 919759
Static COMPOSITVAC �Static COMPOSITVAC E65 �Static COMPOSITVAC E100
3-ph 400V+N+E 919780 919781
For Mobile COMPOSITVAC �Mobile COMPOSITVAC E25 �Mobile COMPOSITVAC E40 �Mobile COMPOSITVAC E65
Suction hose Ø20 x 1000 with GEKA connections both sides 713985
Spireacier hose (linear meter) Ø20 056350
For Static COMPOSITVAC �Static COMPOSITVAC E65 �Static COMPOSITVAC E100
Equipped 80 L receiver 1-ph 230V+E 615345
Independent 80 L receiver, with pneumatic vacuum control 621197
Additional GEKA connection 3/4” male 359980
COMMON OPTIONS
Resin trap 613948
Degassing vacuum chamber see page 663
2
1
375
825
1000
5 valves 3/4”female
Independent 80 L receiver, with pneumatic vacuum control
To vacuumpump(1/2")
Pneumatic vacuum control
Accessory and option references
64
Dimensions
Further to application and configuration – Consult us
Chamber references
VACUUM CASTING MACHINE MIXER CASTING MACHINE
1Heating device
for mixingInner lighting
and mixer
2
• Lubricated rotary vane vacuum pumps EVISA type• Painted steel chamber• Manual or automatic adjustment of vacuum level• Sight glass door• Sliding lower tray• Heating device for the mixture• External plug for R.I.M. process• Inner lighting• Sliding degassing drawer• Mixer• Manual or pneumatic device for casting
under vacuum• Automation of vacuum cycles• Customized chambers on request
2
2
1
• Flow rates from 25 to 200 m3/h further to the chosen EVISA pump.For more details on EVISA range, report to page 6.
• Chamber useful dimensions examples (l x h x d)600 x 600 x 600600 x 1400 x 750
• Maxi vacuum : 5 mbar abs. (-995 mbar rel.) with EVISA pump
3-ph 400V+N+E
Standard power supply
• Plaster, resin, silicon degassing and casting under vacuum• Parts drying• Products dehydration• Resin mixing under vacuum• Impregnation under vacuum• Bounding under vacuum• Accelerated ageing tests under vacuum
Automatic vacuum chambers
Specifications are subject to be changed without notice
Characteristics
Using examples
�Vacuum casting machine �Mixer casting machine
3-ph 400V+N 914550 916094
Door seal per meter 060305
VACU
UM
plants
65
Dimensions
Chamber references
• Vacuum degassing plant• Vacuum caisson with safety sight glass door• Possibility to customize the level of equipment• MILLENIUM control board• Digital display of the pressure• Hinges with progressive distortion
MODELVAC
740 990
1460
740 990
775
740 960
775
3-ph 400V+N+E
Standard power supply
INNER CHAMBER 603 INNER CHAMBER 600
INNER CHAMBER 603 INNER CHAMBER 600
INNER CHAMBER 603 INNER CHAMBER 600
INNE
RCH
AMBE
R60
0
INNER VOLUME 216 LITRES
INNER VOLUME 216 LITRES INNER VOLUME 216 LITRESE25 > E200 PUMP
INNE
RCH
AMBE
R60
0IN
NER
CHAM
BER
600
To the pump
Tothe
pump
Automatic vacuumchambers
Specifications are subject to be changed without notice
all vacuum pumps pumps E25 to E100 pumps E150 to E200
Vacuum chamber alone * 815576
Vacuum chamber with control board * 815577Vacuum chamber with control board, 815578 815609mounted on a table for lodgingthe vacuum pump *Door seal per meter 060305
*vacuum pump, filter, hose, non return valve : not included
Characteristics
• Flow rates from 25 to 200 m3.h-1 further to the chosen EVISApump. For more details on EVISA range, report to page 6.
• Chamber useful dimensions examples (l x h x d)600 x 600 x 600
• Maxi vacuum : 5 mbar abs. (-995 mbar rel.) with EVISA pump
66
Specifications are subject to be changed without notice
Degassing vacuum chambers• Vacuum chamber made of painted steel• Inside dimensions : Ø500 x 400• Movable cover with 2 handles and optional sight glass• Ø80 vacuum gauge• Insulation valve F 1”1/4• Unloading valve• Tightness with silicone seal
Dimensions
Chamber references
671
556
496
COVER WITHOUT SIGHT GLASSCover weight : 15 kg
COVER WITH SIGHT GLASSCover weight : 17 kg
Insulation valve Unloading valve
Chamber with sight glass 618538
Chamber without sight glass 618537
Cover seal per meter 060305
Dimensions References
• Polycarbonate bell jar for degassing under vacuum• 17 litre useful volume• Vacuum gauge• Insulation valve• Unloading valve• Easy using
Vacuum bell jar
ØA
B
D
CD
17 litresØ A 290B 380C 210D 1/4”
17 litresVacuum bell jar 620006Seal 361382
VACU
UM
plants
67
Plant references
Dimensions
• Painted steel automatic vacuum chamber• EVISA rotary vane vacuum pumps type• Integration of the vacuum process in
an automated production line• Reliability and safety for the operators• High vacuum level• Very high paces
Consult us
1900
2340
1210
CHAMBER OPENEDCHAMBER CLOSED
Automatic vacuum chambers
Specifications are subject to be changed without notice
68
• Static or mobile vacuum plants for lubricants extraction• Maxi level obturator mounted on the receiver• Protection drain trap with obturator• Suction hose with quick coupling
VIDANGEMIL’Sstatic and mobile vacuum plants
For more details on EVISA range, report to page 6. For PS pumps, reports page 34
VIDANGEMIL’S E25 V50 VIDANGEMIL’S E25 V10
Working stationwith automatic
winder
1
Static VIDANGEMIL'S NOMINAL POWER RECEIVER NOISE OILCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB(A) L
TYPE 50 Hz 60 Hz 50 Hz 60 Hz� PS 12VH V07 pneumatic 7,4 8,9 0,36 0,43 70 57 -� E25 V50 manual 30 36 0,75 0,90 500 60 1,5� E25 V50 pneumatic 30 36 0,75 0,90 500 60 1,5� E25 V50 electric 30 36 0,75 0,90 500 60 1,5� E40 V50 pneumatic 47 56 1,10 1,30 500 62 1,5� E65 V50 pneumatic 65 78 1,50 1,80 500 65 4,0
Mobile VIDANGEMIL’S NOMINAL POWER RECEIVER NOISE OILCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L
TYPE 50 Hz 60 Hz 50 Hz 60 Hz� PS 12VH V07 7,4 8,9 0,36 0,43 65 57 -� E25 V10 30 36 0,75 0,90 100 60 1,5
Specifications are subject to be changed without notice
Characteristics
VACU
UM
plants
69
Plant references
ØCØA
ØB
A
ØD
E
C
D
B
576 493
1167
Dimensions
VIDANGEMIL’S EVISA V50 VIDANGEMIL’S PS12 V20
Vacuum plants for lubricant extraction
A B C D E ØA ØB ØC* ØDE25 V50 1180 2110 1050 690 470 M2” F1”1/4 Ø10 Ø12E40 V50 1180 2110 1050 690 470 M2” F1”1/4 Ø10 Ø12E65 V50 1274 2110 1200 740 470 M2” F1”1/4 Ø10 Ø12
* crimped connection
Static VIDANGEMIL'S �PS12 V20 �E25 V50 �E25 V50 �E25 V50 �E40 V50 �E65 V50pneumatic manual pneumatic electric pneumatic pneumatic
1-ph 230V 919604 916938
3-ph 400V+N+E 915491 913554 918648 918813 918577
Mobile VIDANGEMIL’S �PS12 VH V07 �E25 V10
970654 970630
Articulated automatic winder with network 1 winder 2 winders 3 winders 4 winders 5 windersconnection Ø20, length 500 and wall fixation support 613447 613448 613449 613450 613451
Retention vat (on per winder) 360015
1
Specifications are subject to be changed without notice
Tool references
70
• Static or mobile vacuum plants for a selective suction of fluids• Maximal suction force : 99% of vacuum• Simultaneous suction of several fluids• Transfer tanks with maxi level obturator• Tank emptying device by overpressure
RECUPMIL’Sstatic and mobile
For more details on EVISA range, report to page 6.
Dimensions
Mobile RECUPMIL’S WIDTH DEPTH HEIGHTmm mm mm
�RECUPMIL’S 4 NG 1200 700 1600
Storage receivers
CAPACITY WIDTH DEPTH HEIGHT RECEIVER WEIGHTL mm mm mm kg
50* 300 300 1280 30100 400 400 1570 45200 500 500 1570 80500 600 930 2050 1401500 1100 1470 2520 3003000 1400 1770 2520 4005000 1600 1950 3100 500
Pump mounted on receiver from 500 L model* wall fixation
Working stationwith articulatedbracket at 180°
and hose spanner
4
RECUPMIL'S 4 NGfor suction of
4 different fluids
1
Specifications are subject to be changed without notice
Mobile RECUPMIL’S NOMINAL POWER RECEIVER NOISE OIL WEIGHTCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L kg
TYPE 50 Hz 60 Hz 50 Hz 60 Hz
�RECUPMIL’S 4 NG 30 36 0,75 0,90 2x50/2x10 60 1,5 2401
Static RECUPMIL’S NOMINAL POWER RECEIVER NOISE OIL WEIGHTCAPACITY CAPACITY LEVEL FILLINGm3.h-1 kW L dB (A) L kg
TYPE 50 Hz 60 Hz 50 Hz 60 Hz�E25 30 36 0,75 0,90 A choisir 60 1,5 35�E40 47 56 1,1 1,30 dans 62 1,5 45�E65 65 78 1,5 1,80 le tableau 65 4 70�E100 96 115 2,2 2,64 ci-dessous 67 4 80
2
To bechosenbelow
Characteristics
Quick-fitcoupling DN 50
for evacuation tocollecting tanker
3
Static RECUPMIL'S(configuration
example)
2
VACU
UM
plants
71
Plant references
Fluid levelsensor with red
flashing light
6Working station
withhose winder
5
Vacuum plants for fluid transfer
Specifications are subject to be changed without notice
1rst solution with bracketBare articulated bracket 2 m 3 m 4 m 5 m
359107 359108 359109 359110Support guide for hoses 1 hose 2 hoses 3 hoses 4 hoses 5 hoses
670056 670057 670058 670104 670105
Tightener without stop (one per hose required) 358010
Tightener with stop (one per hose required) 358180
2nd solution with hose reelArticulated automatic winder with network 1 winder 2 winders 3 winders 4 winders 5 windersconnection Ø20, length 500 and wall bracket 613447 613448 613449 613450 613451
Retention vat (one per winder) 360015
Suction hose Ø20 length 6m with gun valve and quick connector 713452
Suction hose Ø20 length 6m with butterfly BS 3/4” valve, quick connector and PVC adaptator 713453Complete set of nozzles 1 Ø4 long. 400 pot for brake fluid 1 cooling fluid 1 Ø4 x 6 length 1000 oil nozzle 1 PVC pipe 713353
1 spider for brake fluid drain 1 overpressure pot adaptator 1 Ø6 x 8 length 1000 oil nozzle 1 Ø20 length 1000
1 Ø8 x10 length 1000 oil nozzle
Nozzles storage and PLASTICARBU support 613361
Support metallic plate for 2 tanks of 100 L or 2 tanks of 200 L with drain trap and E 25 EVISA pump 213488
Mobile oil drain system volume (70 L capacity) with plug valve and emptying hose 813364
Gear box and motor oil casing driller 916053
4
5
Tool references
�RECUPMIL’S NG 4 1-ph 230V 970202
Static RECUPMIL’S �E25 �E40 �E65 �E100
EVISA vacuum pump 3-ph 400V+N+E 970035 970036 970037 970038
Drain trap protection Type I NG 870041 Type II NG 870042
Mechanical obturator (1 per tank) 1”1/4 770045
Heating starting board (with solenoid valve, timer and hourmeter) 770463 719872 770464 770531
Overpressure emptying at 0,5 bar 670527 670528Equipped total cap. from 0 to 3 500 L : flow rate 25m3/h-1 20L : 670103 1500L : 670051 50L wall fix. : 670143 500L+E65 : 670091
vacuum tank total cap. from 3500 to 5000L : flow rate 40m3/h-1 50L : 670143 3000L : 609404 100L + 20L : 670132 1500L + E25/E40 : 670092
(from 2 total cap. from 5000 to 7500L : flow rate 65m3/h-1 100L : 670048 5000L : 670053 200L + Pot I : 670142 1500L + E65 : 617104
to 6 maxi) total cap. from 7500 to 10000L : flow rate 100m3/h-1 200L : 670049 200L + 20L + Pot I : 670125 3000L + E25/E40 : 670093
500L : 670050 500L + E25/E40 : 670090 3000L + E65/E100 : 670156
Fluid level sensor at 75% with red flashing light 616742
DN 50 adaptator with plug for collect by tanker (option for storage receiver) 670071
2
6
1
3
72
RECUPCARBU
• Driller for metallic and plastic tanks• Fitting on hydraulic cylinder with a Ø25 rod• Cylinder working with compressed air• Patented spine• Safe using without risk of sparks• Possible connection with fuel pumping
and refilling centralized system
PLASTICARBU
Exclusively reserved for plastic tanks perforation
• Adaptation on standard percussion key (not supplied)• Self fixation tool• Possibility of sealing the hole with a plastic cork• Drain by gravity without risk of explosion• Patented by PEUGEOT and CITROEN firms• Possible connection with fuel pumping and
refilling centralized system
Dimensions
Weight : 0,7 kg
~16
00
~12
00
~ 600
RECUPCARBU
RECUPCARBU and PLASTICARBU
Specifications are subject to be changed without notice
108
Ø75
16
141
119
PLASTICARBU
Sleeve 3/8" - dia.14
40m
m-
flexi
ble
conn
ecti
on
VACU
UM
plants
73
Fuel pumping and refillingcentralized system
Specifications are subject to be changed without notice
Tool references
• Centralized vacuum system for fuel extraction from the scrapped vehicles• More safety for the operator• Double-walled storage receiver with leak detector• Filter protected suction and distribution
diaphragm pumps• Equipped articulated automatic winders
CE Marking further toATEX 94/09 directive
References500 L. vertical 1500 L. horizontal 3000 L. horizontal
Storage receiver 718738 718758 718759
Overflow sensorwith buzzer (option) 361631power supply by 9V batterySuction or refilling pump 1 foreseen : number of receivers x number of working stations + number of refilling stations
718739Suction working station 2 foreseen : one by fuel type and by working station
1 winder 2 winders 3 winders
618317 618318 618319Connection kit PLASTICARBU RECUPCARBU Drilling of motor pipe
618320 618321 618322Refilling working station 3 1 winder 1 winder 2 winders 3 winders
618324 618747 618325 618326(gazoline) (diesel oil) (1 gazoline and 1 diesel oil) (2 gazoline and 1 diesel oil)
Retention vat 1 per winder
3600151 : System including a pneumatic diaphragm pump set on a wall fixation with pressure reducer and manometer, a suction hose with stainer
and an exhaust hose.
2 : System set on a wall fixation including an automatic articulated winder and a 6 m hose with manual valve and GEKA quick coupling.
3 : System set on a wall fixation including an automatic articulated winder, a 6 m hose with a filling gun valve (gazoline or diesel oil),a fluidmeter and a connection hose (1m long).
PLASTICARBU RECUPCARBU
Tank driller 970621 970119
Pit hydraulic cylinder 359122Air comsumption per pneumatic pump : 6 m3.h-1 - Compressed air needed : between 6 and 10 bar
Compact unit, ready for use, no installation required 920125Made up of:1 double-walled tank with leak detector, capacity 500 litres1 double-walled diesel fuel tank with leak detector, capacity 500 litres2 level detectors with percentage display1 diesel fuel suction and distribution pump with 3-way flow valve for permutation1 petrol suction and distribution pump2 suctions winders with 10 m hoses2 distribution winders with 5 m hoses and nozzles2 fuel filters2 mechanical volumetersOption 361631 x 22 high level detectors with audible warning signal, powered 9 V battery
74
Specifications are subject to be changed without notice
Plant references
For more details on EVISA pumps, report to page 6.
• Vacuum priming of siphon with a lubricated rotary vanevacuum pump (maxi heigth : 9 m)
• No water contribution, no cavitation risk,insensitivity to freezing, absence of corosion
• Low electric consumption• Available with one, two or three pumps mounted on
a frame and protected by a drain trap with obturator• Rinsing system to eliminate any trace of moisture• MILLENIUM control board with PLC• Possible personnalisation on request
NOMINAL POWER RECEIVER NOISE OILCAPACITY CAPACITY LEVEL FILLING
TYPE m3.h-1 kW L dB (A) L2 pumps version 50 Hz 60 Hz 50 Hz 60 Hz� Priming water pump 2 x E25 2 x 30 2 x 36 2 x 0,75 2 x 0,90 2 x 60 2 x 1,5� Priming water pump 2 x E40 2 x 47 2 x 56 2 x 1,10 2 x 1,30 2 x 62 2 x 1,5� Priming water pump 2 x E65 2 x 65 2 x 78 2 x 1,50 2 x 1,80 2 x 65 2 x 4� Priming water pump 2 x E100 2 x 96 2 x 115 2 x 2,20 2 x 2,64 2 x 67 2 x 4� Priming water pump 2 x E150 2 x 150 2 x 180 2 x 3,00 2 x 3,60 2 x 70 2 x 7� Priming water pump 2 x E200 2 x 190 2 x 228 2 x 4,00 2 x 4,80 2 x 71 2 x 7� Priming water pump 2 x E300 2 x 288 2 x 345 2 x 5,50 2 x 6,60 2 x 73 2 x 7
100 Lor
200 L
NOMINAL POWER RECEIVER NOISE OILCAPACITY CAPACITY LEVEL FILLING
TYPE m3.h-1 kW L dB (A) L1 pump version 50 Hz 60 Hz 50 Hz 60 Hz� Priming water pump 1 x E25 30 36 0,75 0,90 60 1,5� Priming water pump 1 x E40 47 56 1,10 1,30 62 1,5� Priming water pump 1 x E65 65 78 1,50 1,80 65 4� Priming water pump 1 x E100 96 115 2,20 2,64 67 4� Priming water pump 1 x E150 150 180 3,00 3,60 70 7� Priming water pump 1 x E200 190 228 4,00 4,80 71 7� Priming water pump 1 x E300 288 345 5,50 6,60 73 7
100 Lor
200 L
Characteristics
�E25 �E40 �E65 �E100 �E150 �E200 �E300
1 pump version 3-ph 400V+N+E 918327 918328 918329 918330 918331 918332 918333
2 pumps version 3-ph 400V+N+E 918888 918889 918890 918891 918892 918893 918894HDPE 100 litres tankwith conductive sensors 720622
Galvanized 200 litres tankwith float sensors 718334
VACUUM PRIMING OF WATER PUMPS
VACU
UM
plants
75
Specifications are subject to be changed without notice
Dimensions
A
C
DØBB
E
1360
550
556
1605
550530
PRIMING WATER PUMPS HDPE VACUUM TANK OF 100 LITRES
200 LITRES TANK GALVANIZED VERSION
Network connection ØA
G1"1/4 male
To atmosphericpressure
G1"1/4 female1 PUMP VERSION A B C D E ØA ØB�E25 3-ph 400V 565 680 985 340 600 G1” 1/4 16�E40 3-ph 400V 565 680 985 340 600 G1” 1/4 16�E65 3-ph 400V 750 800 1000 525 750 G1” 1/4 16�E100 3-ph 400V 750 800 1000 525 750 G1” 1/4 16�E150 3-ph 400V 1015 1210 1160 740 1180 G1” 1/4 16�E200 3-ph 400V 1015 1210 1160 740 1180 G1” 1/4 16�E300 3-ph 400V 1015 1210 1160 740 1180 G1” 1/4 16Dimensions expressed in mm
2 PUMPS VERSION A B C D E ØA ØB�E25 3-ph 400V 945 680 985 670 600 G1” 1/4 16�E40 3-ph 400V 945 680 985 670 600 G1” 1/4 16�E65 3-ph 400V 1235 800 1000 960 750 G1” 1/4 16�E100 3-ph 400V 1235 800 1000 960 750 G1” 1/4 16�E150 3-ph 400V 1715 1210 1160 1390 1180 G1” 1/4 16�E200 3-ph 400V 1715 1210 1160 1390 1180 G1” 1/4 16�E300 3-ph 400V 1715 1210 1160 1390 1180 G1” 1/4 16Dimensions expressed in mm
To vacuum pump
To atmosphericpressure
To vacuum pump
G1"1/4 male
Vacuum priming of water pumps
76
LABOVAC 1
Specifications are subject to be changed without notice
Characteristics
• 3-phase, 400V/50Hz• Other tensions on request
Standard power supplies
Available set-up
Assembly with separator for partial water recycling �
Assembly without separator for partial water recycling �
Bacterial filtration �
Network alarm �
� standard equipment � optional equipment
4Suction hoses
Networkconnection alarm
2
3Vertical vacuum
receiver
Water supply
Bacterial filtration1
Water flowregulation
Air/waterseparator trap
50 Hz
NOMINALCAPACITYm3.h-1
POWER
kW
RECEIVERCAPACITY
L
NOISELEVELdB(A)
WATER CONSU.* (L/min) WEIGHT
kgopened range with separator
�LABOVAC 1 S26 27 0.75 300 68 4 2 135�LABOVAC 1 S51 49 1.5 300 68 4 2 140�LABOVAC 1 S126 89 3 300 67 8 4 160�LABOVAC 1 S161 152 4 500 65 16 8 260�LABOVAC 1 S251 230 5.5 500 65 16 8 280�LABOVAC 1 S325 290 7.5 500 70 20 12 330* consumption for a low pressure less than 200 mbar abs.
• Automatic and compact vacuum plants for laboratories• Liquid ring vacuum pump ANTIGUA type• Partial water recycling system• Capable of handling draw-in dust• Water flow regulation• Easy setting• Electromechanical control board (2 thresholds vacuum switch)• Simple bacterial filtration with optional by-pass
VACU
UM
plants
77
Liquid ring vacuum plants
Specifications are subject to be changed without notice
Dimensions
ØA
ØEV
l L
ØR
H
H1
Øe
ØE
TYPE
LENGTH
L
HEIGHT WIDTH(l) ØA ØR ØE ØEV Øe
H H1 without filtration with filtration
�LABOVAC 1 S26 1700 1050 1450 650 800 1"1/2 1" 3/8" 3/4" 3/4"
�LABOVAC 1 S51 1700 1050 1450 650 800 1"1/2 1" 3/8" 3/4" 3/4"
�LABOVAC 1 S126 1700 1250 1550 650 800 1"1/2 1"1/4 3/8" 1"1/4 1"1/4
�LABOVAC 1 S161 1950 1400 1750 750 1100 1"1/2 1"1/2 3/8" 1"1/2 2"
�LABOVAC 1 S251 1950 1500 1850 980 1100 1"1/2 1"1/2 3/8" 1"1/2 2"
�LABOVAC 1 S325 1950 1500 2000 980 1100 1"1/2 1"1/2 3/8" 1"1/2 2"
H : Height without partial recovery deviceH1 : Height with partial recovery device
Dimensions expressed in mm
Plant references
Accessory and option references
�S26 R3 �S51 R3 �S126 R3 �S161 R5 �S251 R5 �S325 R5LABOVAC 1 - 50 Hz with separator 920771 920772 920773 920774 920775 920776LABOVAC 1 - 50 Hz without separator 920022 920023 920024 920025 920026 920027
�S26 R3 �S51 R3 �S126 R3 �S161 R5 �S251 R5 �S325 R5
Simple bacterial filtration with by-passmounted on receiver
1 FD30B811833
FD65B811834
FD130B811835
FD320B811836
Network alarm2 1 vacuum switch + 1 vacuum gauge (dry contact) 708510
Optional transformer 400V/230V fitting 611099
Additional receiver with vacuum gaugeand draining valve
3 500 litres710486 or
1000 litres710488 or
2000 litres710490
Connection hose for additional receiver4 710992 710993 710994
78
LABOVAC 2
Specifications are subject to be changed without notice
• Automatic and compact vacuum plants for laboratories• Liquid ring vacuum pumps ANTIGUA type• Partial water recycling system• Capable of handling draw-in dust• Water flow regulation• Easy setting• MILLENIUM PLC control board or electronic cards CYCLIC 2020• Simple bacterial filtration with by-pass mounted on plant
or delivered separately
Characteristics
50 Hz
NOMINALCAPACITYm3.h-1
POWER
kW
RECEIVERCAPACITY
L
NOISELEVELdB(A)
WATER CONSU.* (L/min) WEIGHT
kgopened range with separator
�LABOVAC 2 S26 2 x 27 2 x 0.75 500 68 2 x 4 2 x 2 210�LABOVAC 2 S51 2 x 49 2 x 1.5 500 68 2 x 4 2 x 2 220�LABOVAC 2 S126 2 x 89 2 x 3 500 67 2 x 8 2 x 4 260�LABOVAC 2 S161 2 x 152 2 x 4 800 65 2 x 16 2 x 8 430�LABOVAC 2 S251 2 x 230 2 x 5.5 800 65 2 x 16 2 x 8 470�LABOVAC 2 S325 2 x 290 2 x 7.5 800 70 2 x 20 2 x 12 570* consumption for a low pressure less than 200 mbar abs.
3Vertical vacuum
receiver
Suction hoses4
Bacterial filtration2
Water flowregulation
Water supply
Available set-up
Assembly with separator for partial water recycling �
Assembly without separator for partial water recycling �
CYCLIC 2020 �
MILLENIUM �
Bacterial filtration mounted on receiver �
Wall fixation bacterial filtration �
Network alarm �
� Standard equipment � Optional equipment
• 3-phase, 400V/50Hz• Other tensions on request
Standard power supplies
Air/waterseparator trap
VACU
UM
plants
79
Liquid ring vacuum plants
Specifications are subject to be changed without notice
Dimensions
l
ØA
ØEV
ØE
ØR
L
H
H1
Øe
TYPE
LENGTH
L
HEIGHT WIDTH(l) ØA ØR ØE ØEV Øe
H H1 without filtration with filtration
�LABOVAC 2 S26 1950 1200 1450 1000 1100 1"1/2 1"1/4 1/2" 1"1/4 3/4"
�LABOVAC 2 S51 1950 1200 1450 1000 1100 1"1/2 1"1/4 1/2" 1"1/4 1"1/4
�LABOVAC 2 S126 1950 1400 1750 1000 1200 1"1/2 1"1/2 1/2" 1"1/2 2"
�LABOVAC 2 S161 2350 1500 1900 1050 1250 2" 2" 1/2" 1"1/2 2"
�LABOVAC 2 S251 2350 1600 1950 1050 1250 2" 2" 1/2" 1"1/2 2"
�LABOVAC 2 S325 2350 1600 2100 1050 1250 2" 2" 1/2" 1"1/2 2"
H : Height without partial recovery device H1 : Height with partial recovery device Dimensions expressed in mm
Plant references
Accessory and option references
�S26 R5 �S51 R5 �S126 R5 �S161 R8 �S251 R8 �S325 R8LABOVAC 2 C202050Hz
With separator 920783 920784 920785 920786 920787 920788Without separator 920034 920035 920036 920037 920038 920039
LABOVAC 2 MIL50Hz
With separator 920795 920796 920797 920798 920799 920800Without separator 920046 920047 920048 920049 920050 920051
�S26 R5 �S51 R5 �S126 R5 �S161 R8 �S251 R8 �S325 R8
Simple bacterial filtration with by-passmounted on receiver
2 FD65B812306
FD130B812308
FD320B811836
FD600B811837
Wall fixation bacterial filtration withby-pass delivered separately
811849 811850 811851 811852
Network alarm with sensor version CYCLIC 2020 611027version MILLENIUM 616690
Optional transformer 400V/230V fitting 611099
Additional receiver with vacuum gaugeand draining valve
3 500 litres710486 or
1000 litres710488 or
2000 litres710490
Connection hose for additional receiver4 710992 710993 710994
80
Characteristics
CRYOLIS
• Automatic and compact vacuum plantsfor laboratory applications
• Lubricated rotary vane vacuum pumps• Pumps protection with cryogenic condenser
at -60°C or at -110°C• Possible simultaneous running by several
vacuum plugs• Low noise level• Optimal vacuum level (3,7 to 7,5 Torr)
Specifications are subject to be changed without notice
NOMINAL POWER NOISE OILCAPACITY LEVEL FILLING
m3.h-1 kW dB(A) L50 Hz 60 Hz 50 Hz 60 Hz
�CRYOLIS 1 E40 47 56 1,10 1,30 65 1,5�CRYOLIS 1 E100 96 115 2,20 2,64 70 4,0�CRYOLIS 2 E40 2 x 47 2 x 56 2 x 1,10 2 x 1,30 68 2 x 1,5�CRYOLIS 2 E100 2 x 96 2 x 115 2 x 2,20 2 x 2,64 73 2 x 4,0
Drain trap capacity : 10 litres Other capacities on request
Vacuum distillation ina pharmaceutical lab
Plant references
�E40 �E100
CRYOLIS 1 3-ph 400V+N+E 918971 918972
CRYOLIS 2 3-ph 400V+N+E 918534 918970
Vacuum plants for laboratories
81
VACU
UM
plants
Specifications are subject to be changed without notice
Dimensions
A
ØE
A C
ØE
B
CRYOLIS 1
CRYOLIS 2
�CRYOLIS 1E40 E100
A 830 830B 1455 1455C 820 890ØE 1"1/4 1"1/4
�CRYOLIS 2E40 E100
A 1410 1410B 1455 1455C 840 890ØE 1"1/4 1"1/4
Cryogenic condenser
Dimensions expressed in mm
Dimensions expressed in mm
82
Notes
83
• Oil free blowers• Built-in 25μ suction filter• Running and maintenance low costs• Compact assembly under box for intensive cooling
and total protection (ARICA 10P to 60P)• Low noise
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
10
9
8
7
6
5
4
3
2
1
0
10
9
8
7
6
5
4
3
2
1
0
50
45
40
35
30
25
20
15
10
5
0
50
45
40
35
30
25
20
15
10
5
0
30
25
20
17,5
15
12,5
10
7,5
5
2,5
0
30
25
20
17,5
15
12,5
10
7,5
5
2,5
0
10P 15P
25P
10P10P
15P15P
25P25P
10P 15P25P
3PK3PK
6PK6PK
3PK3PK6PK6PK
3PK
6PK
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
60
55
50
45
40
35
30
25
20
15
10
5
0
60
55
50
45
40
35
30
25
20
15
10
5
0
8
7
6
5
4
3
2
1
0
8
7
6
5
4
3
2
1
0
2,5
1,5
2,5
1,5
60
55
50
45
40
35
30
25
20
15
10
5
00 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Ø Noozle (mm)Time (s)
Flow rate (m3.h-1)
Ø Noozle (mm)Time (s)
Flow rate (m3.h-1)
ARICA 3PK and 6PK ARICA 10P to 25P Arica 60P
Arica 3PK and 6PK Arica 10P to 25P Arica 60P
Flow rate (m3.h-1)
Relative pressure (bar)
Capacity/pressure curveLoading time with a 100 L receiverPressure through a nozzle
Capacity/pressure curve
NOMINAL END MOTOR ROTATION NOISE WEIGHTCAPACITY PRESSURE POWER SPEED LEVELm3.h-1 mbar kW rpm dB (A) kg
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz�3PK 4 4,8 1 0,25 0,30 1400 1680 59 6,5�6PK 7 8,4 0,8 0,30 0,36 1400 1680 61 11,5�10P 11 13 0,7* 0,37 0,44 1450 1740 63 20�15P 17,5 21 1 0,55 0,66 1450 1740 65 29�25P 27 32,5 0,7* 0,75 0,90 1450 1740 67 34�60P 55 66 1 2,20 2,64 1450 1740 66 50
* > 0,7 bar contact us
Characteristics
Capacity - pressure curve and average loading time (50 Hz)
AIR
rotary
blow
ers
Oil free rotary vane blowers
ARICA 3PK to 60P
Specifications are subject to be changed without notice
84
Specifications are subject to be changed without notice
ARICA 3PK to 60P
TF
I J
G D E
K M
A
H C
LB
17948
0
23 355
1" 350
325
403652
39 215
157 339
36
9216 16 112
82
127
192
132185
148
75
89
278
10
60220 160
117100
70
124
63
170
121
1080
Arica 60PArica 10P to 25P
SuctionG 1/8”
4 trous Ø7
Suction
Exhaust ØS Exhaust ØSSuction ØR
4 holes M10
ExhaustF1/4” Discharge
safety valve
ExhaustF1/4”
Dischargesafety valve
Arica 6PKArica 3PK
Dimensions
A B C D E F G H I J K L M ØR ØS T�10P 377 234 245 28.5 323 M6 120 196 65 65 66 194 32 1/2” 3/4” Pg 10�15P 445 295 278 24 390 M6 160 235 75 90 74 234 20 3/4” 1” Pg 15�25P 445 295 278 24 390 M6 160 235 75 90 74 234 35 3/4” 1” Pg 15
4 holes Ø7
179
G1”
381
481
355403
652698
23
157
404
39 215333
480
4 x M10
Arica 60P with cooler
Dimensions expressed in mm
85
AIR
rotary
blow
ers
Specifications are subject to be changed without notice
Blower references
Accessory and option references
�3PK �6PK �10P �15P �25P �60PAdditional air filter PA : paper 25PA 51PA 76PA
714926 357947 706190Exhaust hose 770505 770506 618458Fitted pressure gauge Ø50 616730 616731 670507 670508 INCLUDEDFitted check valve MF1/2” MF3/4” 1”
670585 670586 618457Shifted mounting feet 4 pattes 670510Direct starters without regulation 3-ph 400V 770573 770495 770496see page 97 3-ph 230V 770495 770496 770498
1-ph 230V 770631with LG7 control board 3-ph 400V 710421 710422 710423
3-ph 230V 710429 710430 7104321-ph 230V 770471
Cooler 719873
Oil free rotary vane blowers
�3PK �6PK �10P �15P �25P �60PARICA blowers 1-ph 230V 816598 816599
3-ph 230/400V 870546 870548 870549 817827
86
Specifications are subject to be changed without notice
SIRELLA
Capacity - pressure curve (50 Hz)
barPressure
NOMINAL CAPACITYm3.h-1
MOTOR POWERkW
ROTATIONSPEEDrpm
MAXIPRESSURE
bar
NOISELEVELdB(A)
WEIGHTkg
50 Hz 60 HZ 50 Hz 60 Hz 50 Hz 60 Hz�SIRELLA 100 1 bar 95 114 4 4,8 2850 3420 1 78 160�SIRELLA 100 1,4 bar 95 114 5,5 6,6 2850 3420 1,4 78 185�SIRELLA 100 2,2 bar 95 114 7,5 9 2850 3420 2,2 78 190�SIRELLA 150 0,8 bar 145 174 5,5 6,6 2850 3420 0,8 79 195�SIRELLA 150 1,5 bar 145 174 7,5 9 2850 3420 1,5 79 200�SIRELLA 150 2 bar 145 174 9 10,8 2850 3420 2 79 210
Characteristics
5,5 kW
7,5 kW
9 kW
7,5 kW5,5 kW
4 kW
SIRELLA 150
SIRELLA 100
m3.h-1
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
00 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4
• Claw blowers• Very good efficiency• Contact-free compression• Oil-free compression• Air cooling• Low maintenance
87
AIR
rotary
blow
ers
Specifications are subject to be changed without notice
Claw blowers
Dimensions
Pump references
Accessory and option references
A B C B' C' D E F ØS G H I J ØK�SIRELLA 100 1 bar 845 461 720 428 518 125 60 490 G1"1/4 51,5 420 34 360 M10
�SIRELLA 100 1,4 bar 950 461 720 428 518 125 60 490 G1"1/4 51,5 420 34 360 M10
�SIRELLA 100 2,2 bar 950 461 720 428 518 125 60 490 G1"1/4 51,5 420 34 360 M10
�SIRELLA 150 0,8 bar 950 461 875 428 518 125 60 470 G1"1/4 51,5 420 34 360 M10
�SIRELLA 150 1,5 bar 950 461 875 428 518 125 60 470 G1"1/4 51,5 420 34 360 M10
�SIRELLA 150 2 bar 950 461 875 428 518 125 60 470 G1"1/4 51,5 420 34 360 M10
SIRELLA 100 SIRELLA 150
�1 bar �1,4 bar�2,2 bar�0,8 bar�1,5 bar�2 bar3-ph 230/400V 819909 819910 819911 819912 819913 819914
SIRELLA 100 SIRELLA 150�1 bar �1,4 bar�2,2 bar�0,8 bar�1,5 bar�2 bar
Safety valve 362281 362282 362285 362280 362283 362284Connection parts ALU madapter M1"1/4 / DN40: 117134
ALU clamping collar DN40: 361639Centering ring INOX / VITON DN40: 361642Stainless steel hose 500 mm DN40: 361646Stainless steel hose 1 metre DN40: 361647Stainless steel short bellows INOX DN40: 361656
Air cooler See page 17 230 V MONO - 50 Hz A F216: 361326Regulation pressure gauge 359401Base frame assembly 619881
F
A
ØS D
E
H GØK
360
B’
B
C’
C
I
Dimensions expressed in mm
KAV
88
Specifications are subject to be changed without notice
• Compact design• No contamination (without oil)• High efficiency• Low maintenance• Horizontal of vertical axis mounting• For air, non explosive or non harmful gases or gas mixtures• Fluid and ambient air temperature must not exceed 40°C• ATEX production blowers on request
Flow rate (m3.h-1)
Δ pressure (mbar)Single impellerTwin impeller
Characteristics (50Hz)
Capacity - pressure curve (50 Hz)
SINGLE IMPELLERP and M1 : single stageB1 : double stage
POWER
kW
NOISELEVELdB (A)
WEIGHT
kgY006P 1-ph/3-ph 230/400V 0,38 58 13Y011P 1-ph/3-ph 230/400V 0,9 64 16Y020P 1-ph/3-ph 230/400V 1,5 68 24Y030P 3-ph 230/400V 2,2 70 32X40B1 3-ph 230/400V 2,2/3 72 32,5X06M1 3-ph 230/400V 2,2/3/4 71,6 35,2X08M1 3-ph 400V 3/4/5,5/7,5 77,4 68X11M1 3-ph 400V 5,5/7,5/
9,2/11/1581,8 98,5
TWIN IMPELLERB2 : double stageM2 : single stage
POWER
kW
NOISELEVELdB (A)
WEIGHT
kgX05B2 3-ph 400V 2,2/3/4 74 43,5X06B2 3-ph 400V 4/5,5 75 61,5X08B2 3-ph 400V 5,5/7,5/9,2 80,3 110,5X11B2 3-ph 400V 11/15/18,5 85,9 172X09M2 3-ph 400V 9,2/11/15/18,5 85 158X10M2 3-ph 400V 11/15/18,5 86,4 163X11M2 3-ph 400V 11/15/18,5/22 88 186,5
1Silencer filter
32Safety valve fittedon T-square with
non-return valve
X11 M2
X10 M2
X11 B2X09 M2
X11 M1
X08 B2
X06 B2X08 M1
X05 B2X06 M1
X40 B1
Y030P
Y020P
Y011P
Y006P
11
15
18.5
2211
1518.5
9.211
15
1511
11
5.57.5
9.2 18.5
15
18.5
9.27.5
5.5
5.5
4
5.5
4
33
2.2
43
2.2
4
2.2
3
7.5
7.5
0 100 200 300 400 500
1800
1700
1600
1500
1400
13001200
1100
1000
900
800
700
600
500
400
300
200
150
120
100
80
40
60
20
100
AIR
rotary
blow
ers
89
Side channel blowers
Specifications are subject to be changed without notice
Dimensions
Blower references
Accessory and option references
SINGLE IMPELLERTYPE A B D E F K ØI and ØOY006P Ø250 257 205 230 256 85 1”1/4Y011P Ø286 306 225 255 261 95 1”1/2Y020P Ø325 345 260 296 323 115 2”Y030P Ø373 383 290 325 377 140 2”X40B1 Ø350 370 245 270 458 235 1”1/2X06M1 Ø376 443 290 325 386 140 2”X08M1 Ø454 542 448 478 550 300 3”X11M1 Ø540 645 508 538 638 300 4”
TWIN IMPELLERTYPE A B D F K L ØI and ØOX05B2 366 444 260 570 115 55 2”X06B2 398 474 290 703 140 59 2”X08B2 500 698 448 854 300 82 3”X11B2 593 813 509 1000 300 91 4”X09M2 492 610 478 850 500 112 130X10M2 516 623 478 850 500 112 130X11M2 542 650 510 870 500 110 130
A
B
D
E
K
F
F
B
K
L
DØO
AØI A F
ØI ØO
D K
B
L
SINGLE IMPELLER RANGE TWIN IMPELLER RANGEPower (kW) Y006P Y011P Y020P Y030P X40B1 X06M1 X08M1 X11M1 X05B2 X06B2 X08B2 X11B2 X09M2 X10M2 X11M2
3-ph 400V 0,38 4160871-ph 400V 0,38 4160973-ph 400V 0,9 4160881-ph 400V 0,9 4160983-ph 400V 1,5 4160891-ph 400V 1,5 416099
3-ph 400V 2,2 416090 425040 425000 4250123 425041 425001 425003 4250134 425002 425004 425014 425015
5,5 425005 425007 425016 4250177,5 425006 425008 4250189,2 425009 425019 42504211 425010 425020 425043 425046 42508615 425011 425021 425044 425047 425087
18,5 425022 425045 425048 42508822 425089
SINGLE IMPELLER RANGE Y006P Y011P Y020P Y030P X40B1 X06M1 X08M1 X11M1
Silencer filter1 609449 609450 609451 609450 609451 619924 621190
Safety valve fitted on T2 619942 619943 620261 620262 619943 619944 Consult usNon-return valve3 619932 619933 619934 619933 619934 619935 619936Hose L:200-MM 1"1/4 L:250-MM 1"1/2 L:250-MM 2" L:250-MM 1"1/2 L:250-MM 2" L:330-MM 3" L:330-MM 4"
719927 719928 719929 719928 719929 719930 719926Sound-proofing hood 425023 425024 425025Flow converting valve electrical version 230V – 1ph – 50Hz 425090 425092Flow converting valve electropneumatic version 230V – 1ph – 50Hz / 10 bar maxi 425091 425093
Y006P to Y030P / X06M1 to X11M1 / X40B1 X05B2 to X11B2 X09M2 to X11M2
TWIN IMPELLER RANGE X05B2 X06B2 X08B2 X11B2 X09M2 X10M2 X11M2
Silencer filter1 425052 425053 425054 362240* 361422*
Safety valve fitted on T2 619944 Consult us 619946 425064*Non-return valve3 919934 619935 619936 Non availableHose L: 250 - MM 2"
719929L: 330 - MM 3"
719930L: 330 - MM 4" L: 330 - MM 5"
719926 721186Sound-proofing hood 425026 425027 425028
* To be fitted on pipeline
ROOTS RS
90
This blower is provided with three lobe rotors, closed and dynamically balanced.Housed in a cast iron cylinder which has a specific system on the outlet side that obtainsa progressive compression and, consequently, a reduction of the pulsation at the pointwhere it starts.
Helical gears hardened and ground according DIN-6. The fitting on the shaft is conical.Oil splash provides lubrication to both gears and bearings.The sealing between the cylinder and oil housings is through labyrinth segment seal andintermediate condenser holes.A radial lip seal guarantees the drive shaft sealing.
Low pulsation and high frequency
Construction features Manufacturing materials
1. Protection filter with adjusting pipefor relief valve
2. Blower3. Base frame and silencer4. Rubber sleeve5. Non-return valve6. Relief valve
7. Drive guard8. Electric motor9. Rubber feet10. Connecting pipe with flange11. Electric fan*12. Soundproofed box** Optional
Specifications are subject to be changed without notice
Dimensions
Weight KgDN Motor Dimensions expressed in mm Fan Without Box
TYPE kW a b b’ c d e1 e e2 f g h j k l m n r s kW motor30.10 50 11/160M 670 117 227 339 60,3 154 446 115 550 505 600 250 160 818 354 850 1000 900 0,25 165 9030.20 80 15/160M 785 148 258 440 88,9 195 455 170 595 535 650 290 170 965 374 940 1050 980 0,55 225 11030.30 80 18,5/160L 785 148 258 440 88,9 195 455 170 595 535 650 290 170 965 374 940 1050 980 0,55 230 11031.20 100 30/200L 945 172 282 510 114,3 230 640 200 748 765 870 330 240 1109 409 1200 1300 1210 0,75 330 17031.30 100 30/200L 945 172 282 510 114,3 230 640 200 748 765 870 330 240 1140 409 1200 1300 1210 0,75 360 17032.20 100 55/250M 975 172 282 510 114,3 230 640 200 748 765 870 330 240 1109 409 1200 1300 1210 0,75 420 17032.30 150 75/250M 1140 232 352 727 168,3 257 745 230 840 900 1002 390 275 1447 460 1392 1450 1410 0,75 600 270
CylinderHead-plates GG-20 cast ironGear andbearing housing
Shaft-piston CK-45Sizes forged steelGears Hardened and
ground steel14 Ni Cr 10
AIR
rotary
blow
ers
91
Performance data refer to : δ = 1,2 Kg/m3 (P1 = 1 bar abs. T1 = 20°C)Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at distance of 1 m. Tolerance : ± 2dB(A)Δt °C : Increase of temperature
Δp/mbar Size Type 30.10 / DN 50 30.20 / DN 80Q1 m3.h-1 44 78 112 146 173 207 234 254 275 69 115 162 208 245 292 329 357 385Δt °C 53 41 36 34 32 31 30 30 30 47 38 34 32 31 30 30 29 29rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2860 2850 2850 2895 2895 2895 2895 2895 2910 2850 2850 2895 2895 2895 2895 2910 2910 2910
300 kW N abs kW 1,0 1,3 1,7 2,0 2,3 2,6 2,9 3,1 3,3 1,3 1,8 2,3 2,8 3,1 3,6 4,0 4,3 4,6N mot. kW 1,5 2,2 2,2 3 3 3 4 4 5,5 2,2 2,2 3 3 4 4 5,5 5,5 5,5
dB (A) with box 66 68 72 75 77 79 82 83 85 68 71 74 77 78 80 81 83 84without box 63 63 63 64 64 64 64 65 65 63 63 64 64 64 64 64 65 65
Q1 m3.h-1 37 70 104 138 165 199 226 247 267 59 106 152 199 236 283 320 347 376Δt °C 86 61 52 47 45 43 42 41 40 73 55 49 45 43 42 41 40 39rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2860 2850 2895 2895 2895 2895 2910 2910 2910 2850 2895 2895 2895 2910 2910 2910 2910 2910
400 kW N abs kW 1,2 1,7 2,1 2,6 2,9 3,3 3,7 4,0 4,2 1,7 1,8 2,9 3,5 4,0 4,6 5,1 5,4 5,8N mot. kW 1,5 2,2 3,0 3,0 4,0 4,0 5,5 5,5 5,5 2,2 3,0 3,0 4,0 5,5 5,5 5,5 7,5 7,5
dB (A) with box 66 68 72 75 77 79 82 84 85 68 71 75 78 79 80 82 84 85without box 63 63 64 64 64 64 64 65 65 63 63 64 64 64 64 64 65 65
Q1 m3.h-1 64 97 131 158 192 220 240 260 51 97 144 190 227 274 311 339 367Δt °C 84 69 62 59 56 54 53 52 106 75 64 59 56 54 52 51 50rpm roots 1900 2400 2900 300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2895 2895 2895 2910 2910 2910 2910 2895 2895 2895 2910 2910 2910 2910 2910 2910
500 kW N abs kW 2,0 2,6 3,1 3,5 4,1 4,5 4,8 5,1 2,1 2,8 3,5 4,3 4,8 5,6 6,2 6,6 7,0N mot. kW 3,0 3,0 4,0 4,0 5,5 5,5 7,5 7,5 3,0 3,0 4,0 5,5 5,5 7,5 7,5 7,5 7,5
dB (A) with box 70 72 77 80 82 85 86 86 69 72 75 78 79 80 82 85 85without box 63 63 63 64 64 64 67 67 63 63 64 64 64 64 64 65 65
Q1 m3.h-1 57 91 125 152 186 213 233 254 90 136 183 220 266 304 332 359Δt °C 112 89 78 73 69 67 65 64 98 82 73 69 66 64 63 62rpm roots 1900 2400 2900 3300 3800 4200 4500 4800 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2895 2895 2910 2910 2910 2910 2910 2895 2910 2910 2910 2910 2910 2915 2915
600 kW N abs kW 2,4 3,0 3,6 4,1 4,8 5,3 5,7 6,0 3,3 4,1 5,0 5,7 6,6 7,2 7,8 8,3N mot. kW 3,0 4,0 4,0 5,5 5,5 7,5 7,5 7,5 4,0 5,5 7,5 7,5 7,5 7,5 11,0 11,0
dB (A) with box 71 74 78 80 82 85 87 87 74 755 78 79 80 83 86 86without box 64 64 65 65 65 68 68 69 64 64 64 64 64 64 65 65
Q1 m3.h-1 85 119 146 180 208 228 248 130 176 213 260 297 325 353Δt °C 111 96 89 83 80 8 76 100 89 84 79 76 75 74rpm roots 2400 2900 3300 3800 4200 4500 4800 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2910 2910 2910 2910 2910 2910 2910 2910 2910 2910 2915 2915 2915
700 kW N abs kW 3,5 4,2 4,8 5,5 6,1 6,5 6,9 4,8 5,8 6,5 7,5 8,3 8,9 9,5N mot. kW 4,0 5,5 5,5 5,5 7,5 7,5 7,5 5,5 7,5 7,5 7,5 11,0 11,0 11,0
dB (A) with box 75 79 80 83 85 87 87 75 78 79 80 83 86 86without box 65 65 65 66 68 69 69 64 64 64 64 64 66 65
Q1 m3.h-1 114 141 175 202 223 243 169 206 253 290 318 346Δt °C 115 105 98 94 91 89 106 99 93 89 87 86rpm roots 2900 3300 3800 4200 4500 4800 2900 3300 3800 4200 4500 4800rpm mot. 2910 2910 2910 2910 2910 2910 2910 2910 2915 2915 2915 2915
800 kW N abs kW 4,7 5,4 6,2 6,9 7,3 7,8 6,5 7,4 8,5 9,4 10,1 10,8N mot. kW 5,5 7,5 7,5 7,5 11,0 11,0 7,5 7,5 11,0 11,0 11,0 11,0
dB (A) with box 82 83 86 87 88 88 80 81 82 84 86 87without box 65 66 68 69 70 70 65 65 65 65 65 66
Q1 m3.h-1 170 197 217 238 200 247 284 312 340Δt °C 113 108 105 102 114 107 103 100 98rpm roots 3800 4200 4500 4800 3300 3800 4200 4500 4800rpm mot. 2910 2910 2910 2910 2915 2915 2915 2925 2925
900 kW N abs kW 6,9 7,6 8,2 8,7 8,3 9,5 10,5 11,3 12,0N mot. kW 7,5 7,5 11,0 11,0 11,0 11,0 11,0 15,0 15,0
dB (A) with box 88 89 90 90 82 84 86 88 89without box 70 71 72 72 65 65 65 66 67
Q1 m3.h-1 307 334Δt °C 113 111rpm roots 4500 4800rpm mot. 2925 2925
1000 kW N abs kW 12,4 13,2N mot. kW 15 15
dB (A) with box 88 89without box 67 68
* Contact us when requested pressures and intake capacities are not shown
Tri-lobe blowers
Specifications are subject to be changed without notice
Characteristics
(to be continued) ROOTS RS
92
Specifications are subject to be changed without notice
Performance data refer to : δ = 1,2 Kg/m3 (P1 = 1 bar abs. T1 = 20°C)Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at distance of 1 m. Tolerance : ± 2dB(A)Δt °C : Increase of temperature
Δp/mbar Size Type 30.30 / DN 80Q1 m3.h-1 93 155 217 280 329 391 441 478 515Δt °C 47 38 34 32 31 30 29 29 29rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2850 2895 2895 2910 2910 2910 2910 2910 2910
300 kW N abs kW 1,7 2,3 2,9 3,5 4,0 4,6 5,1 5,4 5,8N mot. kW 2,2 3,0 4,0 5,5 5,5 7,5 7,5 7,5 7,5
dB (A) with box 73 76 78 79 81 82 84 86 86without box 64 65 65 65 66 66 67 67 67
Q1 m3.h-1 80 143 205 267 317 379 428 466 503Δt °C 72 55 48 45 43 41 40 40 39rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2895 2910 2910 2910 2915 2915 2915 2915
400 kW N abs kW 2,2 3,0 3,7 4,5 5,1 5,9 6,5 7,0 7,5N mot. kW 3,0 4,0 5,5 5,5 7,5 7,5 11,0 11,0 11,0
dB (A) with box 74 76 78 80 82 83 85 88 88without box 65 65 65 66 67 67 67 68 68
Q1 m3.h-1 70 131 194 256 305 368 418 455 492Δt °C 104 74 64 58 56 53 52 51 50rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2910 2910 2910 2910 2915 2915 2915 2915
500 kW N abs kW 2,7 3,6 4,6 5,5 6,3 7,2 8,0 8,6 9,1N mot. kW 4,0 5,5 5,5 7,5 7,5 11,0 11,0 11,0 11,0
dB (A) with box 75 77 78 80 83 84 85 87 87without box 65 65 66 66 66 67 68 69 69
Q1 m3.h-1 122 184 246 296 358 407 445 482Δt °C 97 81 73 69 66 64 63 62rpm roots 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2910 2910 2910 2915 2915 2915 2925 2925
600 kW N abs kW 4,3 5,4 6,5 7,4 8,5 9,4 10,1 10,8N mot. kW 5,5 7,5 7,5 11,0 11,0 11,0 15,0 15,0
dB (A) with box 77 78 81 83 85 87 88 88without box 66 66 67 67 68 69 70 70
Q1 m3.h-1 175 237 286 349 398 436 473Δt °C 99 88 83 79 76 75 73rpm roots 2400 2900 3300 3800 4200 4500 4800rpm mot. 2910 2915 2915 2915 2925 2925 2925
700 kW N abs kW 6,2 7,5 8,6 9,8 10,9 11,7 12,4N mot. kW 7,5 11,0 11,0 11,0 15,0 15,0 15,0
dB (A) with box 80 82 84 86 88 90 90without box 67 68 68 69 70 72 72
Q1 m3.h-1 228 278 340 389 427 464Δt °C 105 98 92 89 87 85rpm roots 2900 3300 3800 4200 4500 4800rpm mot. 2915 2915 2925 2925 2925 2930
800 kW N abs kW 8,5 9,7 11,2 12,3 13,2 14,1N mot. kW 11,0 11,0 15,0 15,0 15,0 18,5
dB (A) with box 82 84 87 88 90 90without box 68 68 69 70 72 72
* Contact us when requested pressures and intake capacities are not shown
Characteristics
AIR
rotary
blow
ers
93
Specifications are subject to be changed without notice
Performance data refer to : δ = 1,2 Kg/m3 (P1 = 1 bar abs. T1 = 20°C)Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at distance of 1 m. Tolerance : ± 2dB(A)Δt °C : Increase of temperature
Δp/mbar Size Type 31.20 / DN 100 31.30 / DN 100Q1 m3.h-1 152 236 320 404 472 556 623 673 724 240 364 488 613 712 836 935 1010 1085Δt °C 38 34 31 30 29 29 28 28 28 36 32 30 29 29 28 28 28 27rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2895 2910 2910 2910 2910 2915 2915 2915 2895 2910 2910 2915 2915 2915 2925 2925 2925
300 kW N abs kW 2,5 3,4 4,3 5,2 5,9 6,8 7,6 8,1 8,6 3,6 4,8 6,1 7,4 8,4 9,7 10,7 11,5 12,2N mot. kW 3,0 4,0 5,5 7,5 7,5 7,5 11,0 11,0 11,0 4,0 5,5 7,5 11,0 11,0 11,0 15,0 15,0 15,0
dB (A) with box 69 71 77 78 80 82 85 87 87 72 74 77 80 82 85 88 89 90without box 64 64 65 65 66 68 68 69 69 64 64 64 66 66 67 68 68 68
Q1 m3.h-1 139 223 307 391 458 542 610 660 710 223 347 472 596 695 820 919 994 1068Δt °C 56 47 44 41 40 39 38 38 38 52 45 42 40 39 38 38 37 37rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2895 2910 2910 2910 2915 2915 2915 2925 2925 2910 2910 2915 2915 2925 2925 2930 2930 2930
400 kW N abs kW 3,2 4,3 5,4 6,6 7,5 8,6 9,5 10,2 10,9 4,5 6,2 7,8 9,4 10,7 12,3 13,6 14,6 15,6N mot. kW 4,0 5,5 7,5 7,5 11,0 11,0 11,0 15,0 15,0 5,5 7,5 11,0 11,0 15,0 15,0 18,5 18,5 18,5
dB (A) with box 70 72 78 79 82 84 86 87 88 73 74 77 81 83 85 88 90 91without box 64 64 65 66 66 68 68 69 70 64 64 64 66 66 67 68 69 69
Q1 m3.h-1 128 212 296 380 447 531 598 649 699 209 333 457 581 680 805 904 979 1053Δt °C 76 62 57 53 51 50 49 48 48 69 59 54 51 50 49 48 47 47rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2910 2910 2910 2915 2915 2925 2925 2925 2930 2910 2915 2915 2925 2925 2930 2930 2940 2945
500 kW N abs kW 3,8 5,2 6,6 7,9 9,0 10,4 11,5 12,3 13,1 5,5 7,5 9,4 11,4 13,0 14,9 16,5 17,7 18,9N mot. kW 5,5 7,5 7,5 11,0 11,0 15,0 15,0 15,0 18,5 7,5 11,0 11,0 15,0 15,0 18,5 18,5 22,0 30,0
dB (A) with box 71 73 77 80 82 85 87 88 89 74 75 78 82 84 86 89 91 91without box 64 64 65 67 68 69 70 70 71 64 64 65 66 67 68 70 71 71
Q1 m3.h-1 118 202 286 370 437 521 588 638 689 196 320 444 568 667 791 891 965 1040Δt °C 99 79 70 66 63 61 60 59 58 89 74 67 63 61 59 58 58 57rpm roots 1400 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2910 2910 2915 2915 2925 2925 2925 2930 2930 2910 2915 2925 2925 2930 2940 2940 2945 2945
600 kW N abs kW 4,5 6,1 7,7 9,3 10,6 12,2 13,4 14,4 15,4 6,5 8,8 11,1 13,4 15,2 17,6 19,4 20,8 22,2N mot. kW 5,5 7,5 11,0 11,0 15,00 15,00 15,00 18,5 18,5 7,5 11,0 15,0 15,0 18,5 22,0 22,0 30,0 30,0
dB (A) with box 71 73 77 80 82 86 89 89 90 75 76 80 84 86 88 91 93 94without box 64 64 65 67 68 70 70 71 72 64 65 66 68 68 70 72 72 73
Q1 m3.h-1 193 277 361 428 512 579 629 680 183 307 431 556 655 779 879 953 1028Δt °C 96 85 79 75 72 71 70 69 110 89 80 75 73 70 69 68 67rpm roots 1900 2400 2900 3300 3800 4200 4500 4800 1400 1900 2400 2900 3300 3800 4200 4500 4800rpm mot. 2910 2915 2925 2925 2930 2930 2940 2940 2915 2915 2925 2930 2940 2940 2945 2945 2945
700 kW N abs kW 7,0 8,8 10,6 12,1 13,9 15,4 16,5 17,6 7,4 10,1 12,7 15,4 17,5 20,2 22,3 23,9 25,5N mot. kW 7,5 11,0 15,0 15,0 18,5 18,5 22,0 22,0 11,0 11,0 15,0 18,5 22,0 22,0 30,0 30,0 30,0
dB (A) with box 74 77 80 82 86 89 90 91 75 78 82 85 87 90 94 95 95without box 65 95 97 98 70 71 72 72 65 65 66 68 68 71 73 74 74
Q1 m3.h-1 268 352 419 503 570 620 671 296 420 544 644 748 868 942Δt °C 100 92 88 84 82 81 80 106 94 88 85 82 80 79rpm roots 2400 2900 3300 3800 4200 4500 4800 1900 2400 2900 3300 3800 4200 4500rpm mot. 2915 2925 2925 2930 2940 2945 2945 2925 2930 2940 2940 2945 2945 2945
800 kW N abs kW 9,9 12,0 13,6 15,7 17,4 18,6 19,8 11,4 14,4 17,4 19,8 22,8 25,2 27,0N mot. kW 11,0 15,0 15,0 18,5 22,0 30,0 30,0 15,0 18,5 22,0 22,0 30,0 30,0 30,0
dB (A) with box 78 81 82 87 90 91 91 80 83 86 88 92 95 95without box 65 67 68 70 71 72 72 65 66 68 68 71 73 74
Q1 m3.h-1 344 411 495 562 613 663Δt °C 106 101 96 94 92 91rpm roots 2900 3300 3800 4200 4500 4800rpm mot. 2925 2930 2930 2940 2945 2945
900 kW N abs kW 13,3 15,2 17,5 19,3 20,7 22,1N mot. kW 15,0 18,5 18,5 22,0 30,0 30,0
dB (A) with box 82 84 86 91 92 92without box 68 68 70 72 72 73
Q1 m3.h-1 403 487 554 605 655Δt °C 114 109 106 104 102rpm roots 3300 3800 4200 4500 4800rpm mot. 2930 2940 2945 2945 2945
1000 kW N abs kW 16,7 19,3 21,3 22,8 24,3N mot. kW 18,5 22,0 30,0 30,0 30,0
dB (A) with box 86 87 92 93 93without box 69 71 73 73 74
* Contact us when requested pressures and intake capacities are not shown
Characteristics
Tri-lobe blowers
(to be continued) ROOTS RS
94
Specifications are subject to be changed without notice
Performance data refer to : δ = 1,2 Kg/m3 (P1 = 1 bar abs. T1 = 20°C)Tolerance for inlet flow and absorbed power : ± 5%Noise level refer to outdoor measurements at distance of 1 m. Tolerance : ± 2dB(A)Δt °C : Increase of temperatureCharacteristics
Δp/mbar Size Type 32.20 / DN 100 32.30 / DN 150Q1 m3.h-1 300 384 535 603 871 1006 1140 1274 422 542 757 995 1234 1425 1796 1807 1951 2141Δt °C 34 32 30 29 28 27 27 27 33 31 29 28 27 27 27 27 26 26rpm roots 1200 1450 1900 2400 2900 3300 3700 4100 1200 1450 1900 2400 2900 3300 3700 4100 4400 4800rpm mot. 1450 2910 2910 2915 2925 2925 2925 2930 2910 2915 2915 2925 2925 2930 2940 2945 2945 2945
300 kW N abs kW 4,3 5,1 6,7 8,5 10,3 11,7 13,1 14,6 6,0 7,2 9,5 12,0 14,4 16,4 18,4 20,4 21,9 23,9N mot. kW 5,5 5,5 7,5 11,0 15,0 15,0 15,0 18,5 7,5 11,0 11,0 15,0 18,5 22,0 22,0 30,0 30,0 30,0
dB (A) with box 74 74 76 77 81 81 83 86 874 75 77 78 81 82 84 86 88 88without box 68 68 68 69 69 69 70 70 68 68 68 69 69 69 70 70 70 71
Q1 m3.h-1 284 368 519 687 855 989 1124 1258 399 518 733 972 1211 1402 1593 1784 1927 2119Δt °C 47 44 41 39 38 37 37 36 47 44 41 39 37 37 36 36 36 35rpm roots 1200 1450 1900 2400 2900 3300 3700 4100 1200 1450 1900 2400 2900 3300 3700 4100 4400 4800rpm mot. 1450 2910 2915 2915 2925 2930 2940 2940 2915 2915 2925 2930 2940 2945 2945 2945 2945 2945
400 kW N abs kW 5,4 6,5 8,5 10,8 13,0 14,8 16,6 18,4 7,6 9,1 12,0 15,1 18,3 20,8 23,3 25,9 27,7 30,3N mot. kW 7,5 7,5 11,0 11,0 15,0 18,5 22,0 22,0 11,0 11,0 15,0 18,5 22,0 30,0 30,0 30,0 37,0 37,0
dB (A) with box 75 75 76 78 82 82 85 88 75 75 77 79 81 83 84 87 88 89without box 68 68 69 69 69 70 70 71 68 68 69 69 69 70 70 71 71 72
Q1 m3.h-1 279 353 505 673 841 975 1109 1244 379 498 713 952 1190 1381 1573 1763 1907 2098Δt °C 62 57 52 50 48 47 47 46 62 57 52 50 48 47 46 46 45 45rpm roots 1200 1450 1900 2400 2900 3300 3700 4100 1200 1450 1900 2900 2400 3300 3700 4100 4400 4800rpm mot. 1455 2915 2915 2925 2930 2940 2945 2945 2925 2925 2930 2940 2945 2945 2945 2945 2955 2955
500 kW N abs kW 6,5 7,9 10,3 13,0 15,7 17,9 20,0 22,2 9,2 11,1 14,5 18,3 22,1 22,1 28,2 31,3 33,6 36,6N mot. kW 11,0 11,0 11,0 15,0 18,5 22,0 30,0 30,0 15,0 15,0 18,5 22,0 30,0 30,0 37,0 37,0 45,0 45,0
dB (A) with box 75 75 77 78 83 84 87 89 77 77 78 80 82 84 86 88 90 91without box 68 68 69 69 69 70 70 71 68 68 69 69 70 71 71 72 72 73
Q1 m3.h-1 257 341 492 660 828 962 1097 1231 360 479 694 933 1172 1363 1554 1745 1888 2079Δt °C 78 71 65 61 59 57 56 56 79 71 65 61 58 57 56 55 55 54rpm roots 1200 1450 1900 2400 2900 3300 3700 4100 1200 1450 1900 2400 2800 3300 3700 4100 4400 4800rpm mot. 1455 2915 2925 2930 2940 2945 2945 2945 2925 2940 2940 2945 2945 2945 2945 2945 2955 2955
600 kW N abs kW 7,6 9,2 12,1 15,2 18,4 21,0 23,5 26,0 10,8 13,0 17,0 21,5 18,4 29,6 33,2 36,7 39,4 43,0N mot. kW 11,0 11,0 15,0 18,5 22,0 30,0 30,0 30,0 15,0 15,0 22,0 30,0 22,0 37,0 37,0 45,0 45,0 45,0
dB (A) with box 75 76 78 81 84 84 88 88 77 78 79 81 83 85 87 89 91 91without box 68 69 69 70 70 71 71 72 69 69 70 70 71 72 72 72 73 73
Q1 m3.h-1 245 329 481 649 817 951 1085 1220 343 462 677 916 1154 1346 1537 1728 1871 2062Δt °C 96 86 77 72 69 68 67 66 97 87 77 72 69 68 66 65 65 64rpm roots 1200 1450 1900 2400 2900 3300 3700 4100 1200 1450 1900 2400 2900 3300 3700 4100 4400 4800rpm mot. 1460 2925 2925 2930 2945 2945 2945 2945 1460 2925 2925 2930 2945 2945 2945 2945 2955 2955
700 kW N abs kW 8,7 10,6 13,8 17,5 21,1 24,0 26,9 29,9 12,3 14,9 19,5 24,7 29,8 33,9 39,1 42,2 42,2 49,4N mot. kW 15,0 15,0 15,0 18,5 30,0 30,0 30,0 37,0 15,0 18,5 30,0 30,0 37,0 45,0 45,0 55,0 55,0 75,0
dB (A) with box 77 78 79 82 85 86 87 89 78 79 80 82 84 86 88 90 91 91without box 68 69 70 70 71 72 72 73 69 69 70 70 71 72 72 72 73 73
Q1 m3.h-1 234 318 469 637 805 940 1074 1208 446 661 900 1139 1330 1521 1712 1855 2046Δt °C 114 102 90 84 80 78 77 76 103 91 84 80 78 77 75 75 74rpm roots 1200 1450 1900 2400 2900 3300 3700 4100 1450 1900 2400 2900 3300 3700 4100 4400 4800rpm mot. 1460 2925 2930 2940 2945 2945 2945 2955 2940 2645 2940 2945 2945 2965 2965 2955 2970
800 kW N abs kW 9,9 11,9 15,6 19,7 23,8 27,1 30,4 33,7 16,8 22,1 27,9 33,7 38,3 43,0 47,6 51,1 55,7N mot. kW 15,0 15,0 18,5 22,0 30,0 30,0 37,0 45,0 22,5 30,5 37,5 37,5 45,5 55,5 55,5 75,5 75,5
dB (A) with box 78 79 80 83 86 87 88 90 81 82 84 86 88 90 91 92 92without box 68 69 70 71 72 72 73 73 70 70 71 72 72 73 73 71 74
Q1 m3.h-1 459 627 795 929 1064 1198Δt °C 104 96 92 89 87 86rpm roots 1900 2400 2900 3300 3700 4100rpm mot. 2930 2945 2945 2945 2945 2955
900 kW N abs kW 17,4 22,0 26,5 30,2 33,9 37,5N mot. kW 18,5 30,0 30,0 37,0 37,0 45,0
dB (A) with box 85 87 88 90 90 93without box 72 72 73 73 74 75
Q1 m3.h-1 617 785 920 1054 1189Δt °C 108 103 100 98 96rpm roots 2400 2900 3300 3700 4100rpm mot. 2945 2945 2945 2955 2965
1000 kW N abs kW 24,2 29,2 33,3 37,3 41,3N mot. kW 30 37 37 45 55
dB (A) with box 91 91 92 93 94without box 73 74 74 75 75
* Contact us when requested pressures and intake capacities are not shown
AIR
rotary
blow
ers
95
Specifications are subject to be changed without notice
30.10 30.20 30.30 31.20 31.30 32.20 32.30
Soundproofing hood 411025 411026 411027 411028
Air-free and isolating pneumatic valves 616776 616777 616778 616779
and control fitted on T-square (with control)
Starting box star/delta 5,5 kW 7,5 kW 11 kW 15 kW 18,5 kW 22 kW
716056 716057 716058 716059 716060 716061
Temperature control 616064
Other capacities and pressures on request
30.10 30.20 30.30 31.20 31.30 32.20 32.30
Compact group (without motor) 411018 411019 411020 411021 411022 411023 411024
1,5 kW 2,2 kW 3 kW 4 kW 5,5 kW 7,5 kW 11 kW
3-ph motor 400V Δ - 50 Hz - 3000 rpm 411029 411030 411031 411032 411033 411034 411035
15 kW 18,5 kW 22 kW 30 kW 37 kW 45 kW 55 KV
411036 411037 411038 411039 411040 411041 411042
75 kW
411043
RS blower references
Accessory and option references
Tri-lobe blowers
96
Pressure measurementand control
Specifications are subject to be changed without notice
Battery-operated electronic manometerMicroprocessor-driven high-precision compact digital manometer
It uses a piezoresistive pressure sensor,severely tested regarding pressure and tem-perature, and of which features are saved inEEPROM. The integrated microprocessorreads the pressure sensor signal and calcu-lates pressure with a precision of 0,1% inthe temperature range 0 to 50°C.
Pressure is measured and displayed twiceper second. The upper display indicates thecurrent pressure and the lower display indi-cates the maximum (MAX) or minimum(MIN) pressure since the latest RESET.Thismanometer is equipped with 2 control keys.
The left key starts the manometer andallows to select a function such as pressureunit. The right key activates the selectedfunction. It also allows to switch from maxi-mum pressure display to minimum pressuredisplay.
Available functions
RESET : When activating the RESET function, the pressure current value is recorded as MIN or MAX value.ZERO : The ZERO function allows to record any pressure value as a new zero reference.
So atmospheric pressure variations can be balanced.The zero factory adjustment of 3 bar and 30 bar measurement ranges is carried out at 0 bar absolute(when starting the instrument, atmospheric pressure is displayed).For a relative pressure measurement, activate the “ZERO SET” function at the atmospheric pressure.Manometers with 300 bar and 700 bar measurement ranges are calibrated with a 1 bar absolute reference.
CONT : The instrument automatically stops 15 minutes after one of the two keys has been pressed.The CONT function (Continuous) allows to deactivate the automatic stop.
UNITS : Manometers are bar calibrated. Pressure can be displayed in the following units : bar, mBar, hPa, kPA, psi, kp/cm2.
Each manometer is delivered with a gas 1/4” male adapter.An air-tightness coupler allows to position the manometer in an optimum way.
Characteristics
Precision of 0 to 50°C* Typ. 0.1% MR, max 0.2% MRStorage/operating temperature -20…70°C / 0…50°CBalanced temperature range 0…50°CSupply 3V battery, CR2430 typeBattery life ≈ 1000 hours (continuous use)Pressure connector 7/16“ -20 UNF (gas 1/4’’ male adapter delivered)Protection, CEI 529 PF 65Diameter x Height x Thickness 59 x 95 x 32 mmWeight ≈ 125 g* Including linearity, hysteresis, reproducibility, temperature effects and display resolution. Zero stability excluded.
Manometer references
Manometer, coupler and gas 1/4’’ adapter 361017
Full carrying case with manometer 616308
Accessory and option references
Carrying case
Measurement range (MR) Resolutions Overpressures-1…3 bar 1 mbar 10 bar
-1…30 bar 10 mbar 60 bar0…300 bar 100 mbar 400 bar0…700 bar 200 mbar 700 bar
Direct
starter
1to
1,6A
1,6to
2,5A
2,5to
4A
4to
6,3A
6to
10A
9to
14A
13to
18A
17to
23A
20to
25A
24to
32A
3-ph
400V
With
outr
egul
atio
n77
0573
7704
9577
0496
7704
9777
0498
7704
9977
0500
7705
0171
9237
7192
38
With
cont
rolb
ox71
0421
7104
2271
0423
7104
2471
0425
7104
2671
3746
7192
39EV
ISA
C10
(0,3
7kW
-1A)
E17
(0,5
5kW
-2A)
E40
(1,1
kW-2
,6A)
E100
(2,2
kW-5
A)E150
(3kW
-6,6
A)E200
(4kW
-9,3
A)E350
(7,5
kW-1
6A)
E400
(9kW
-22A
)E500
(11k
W-2
4A)
E600
(15k
W-3
0A)
E25
(0,7
5kW
-2A)
E65
(1,5
kW-3
,4A)
E300
(5,5
kW-1
1,4A
)
ARIC
A10
(0,3
7kW
-1,1
A)15
(0,5
5kW
-1,7
A)
25(0
,75k
W-2
A)
KAV
YOO6
(0,3
8kW
-1,1
A)M00
6(0
,4kW
-1,5
A)YO11
(0,7
0kW
-2,5
A)M02
0(1,
3kW
-3,8
A)M03
0(2,
2kW
-5,8
A)M03
9(4k
W-1
0A)
B096
(7,5
kW-1
7,6A
)
M01
1(0
,7kW
-2,2
A)Y020
(1,5
0kW
-4,3
A)M03
1(3k
W-7
,2A)
B075
(4W
-9,5
A)
Y030
(2,2
kW-5
,7A)
M04
0(5
,5kW
-13,
3A)
B083
(5,5
kW-1
3,3A
)
Pist
on13
C1/11C2
(1,5
kW-3
,7A)
20B1
S(2
,2kW
-6.1
A)32
C1/27C2
(4kW
-9A)
com
pres
sors
17C1/16C2
(2,2
kW-5
,1A)
26B1
S(3
kW-8
A)
13B1
S(1
,5kW
-4,1
A)
3-ph
230V
With
outr
egul
atio
n77
0495
7704
9677
0497
7704
9877
0499
7705
00
With
cont
rolb
ox71
0429
7104
3071
0431
7104
3271
0433
7104
34EV
ISA
C10
(0,3
7kW
-1,6
A)E17
(0,5
5kW
-3,2
A)E40
(1,1
kW-4
,3A)
E65
(1,5
kW-5
,8A)
E150
(3kW
-11,
2A)
E200
(4kW
-16,
1A)
E25
(0,7
5kW
-3,5
A)E100
(2,2
kW-8
,4A)
ARIC
A10
(0,3
7kW
-1,9
A)15
(0,5
5kW
-2,8
A)z
25(0
,75k
W-3
,5A)
KAV
M00
6(0
,4kW
-2,6
A)M01
1(0
,7kW
-3,8
A)M02
0(1
,3kW
-6,6
A)M03
0(2
,2kW
-10A
)
M03
1(3
kW-1
2,5A
)
Pist
on13
C1/11C2
17C1/16C2
32C1/27C2
com
pres
sors
(1,2
5kW
-6,4
A)(2
,2kW
-8,8
A)(4
kW-1
5,2A
)
13B1
S(1
,5kW
-7,1
A)20B1
S(2
,2kW
-8,8
A)26
B1S
(3kW
-14A
)
1-ph
230V
With
outr
egul
atio
n77
0631
7705
0277
0503
7705
0477
0632
With
cont
rolb
ox77
0471
7104
2771
0428
7104
3571
0436
EVIS
AC10
(0,3
7kW
-3A)
E25
(0,7
5kW
-5,4
A)E40
(1,1
kW-7
,2A)
Y020
(1,5
kW-1
1A)
ARIC
A3
(0,2
5kW
-1A)
6(0
,3kW
-2A)
PSPS2
(0,2
0kW
-1A)
PS7
(0,2
5kW
-1,5
A)
PS5
(0,2
0kW
-1A)
PS12
(0,3
6kW
-1,8
A)
KAV
M13
2(0
,37k
W-2
,7A)
M13
8(0
,8kW
-5,2
A)M14
8(1
,1kW
-6,9
A)
Y006
(0,3
8kW
-2,5
A)Y011
(0,8
0kW
-6,1
A)
Frequencyconverter
0,75
kW36
1617
1,5
kW36
1618
2,2
kW36
1619
3kW36
1620
4kW36
1621
3-ph
400V
-50H
z5,
5kW36
1622
7,5
kW36
1623
11kW36
1624
15kW36
1625
97
Specifications are subject to be changed without notice
Regulations
Direct startersand frequency converters
PROCOM, CYCLIC 2020,MILLENIUM, …
98
Dimensions
500
700
305
300
270
600
For 4 to 6 motors For 1 to 3 motors
LG 7CYCLIC 2020
MILLENIUMPROCOM
MIL'S is offering several solutions for control and regulation of the vacuum and air plants in Industrial fields.2 regulation modes are proposed :
• “ON/OFF” mode : starts ands stops the motor at pre-set values. This mode is advised for usual lowrunning operations.
• ”FLEXO” mode : starts the motor but stops it only when the pre-set time is reached, independently ofthe pre-set values. This mode is advised for usual high running operations, and to avoid too many motorstarts and stops.
Technology
Managed motors
Managed fluids
Running
Priorities inversion
Control regulation type
Type regulation planning
Hours counter
Running visual display
Maintenance management
Management of premises ventilation
Alarms
Led
Buzzer
Alarms visual display
Dry contact for alarm transfer
Manifold monitoring
Dew point monitoring
REPORT STATUS device connection
Gases monitoring (CO2, CO, O2)
Display - input/output
Screen
RS 485 with JBUS procedure
� Standard equipment � Non available
Characteristics
Specifications are subject to be changed without notice
175
180
165
70115
195
LG7 control board REPORT STATUS device
99
Accessories and option references
REPORT STATUS device for remote alarm transfer (CYCLIC 2020 and PROCOM) contact us
Meter of shielded cable for J-Bus connection (RS 485) from the CYCLIC 2020 or the PROCOM electronic cards 060524
to the REPORT STATUS device
Electrical cord with RJ45 connector to remote 4 alarms from the REPORT STATUS box (provide 3 electrical cords for the 12 alarms) 615892
1
REPORT STATUSdevice
1
� PROCOM � CYCLIC 2020 � MILLENIUM � LG 7 � CONDOR
Dedicated PLC Dedicated PLC Dedicated Electromechanical Electromechanical
1 to 6 1 to 3 2 or 3 1 1
Air or Vacuum Air or Vacuum Air or Vacuum Air or Vacuum Air
Cyclic or fixed Cyclic or fixed Cyclic or fixed � �
ON/OFF regulation or flexo ON/OFF regulation or flexo ON/OFF regulation or flexo ON/OFF regulation or flexo ON/OFF regulation
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
� � � � �
16 lines 1 line 4 lines � �
� � � � �
Control and regulation devicesfor air and vacuum
Specifications are subject to be changed without notice
Regulations
100
Services
MIL’S,aware of your imperatives andrequirements, offers all kind ofservices to enhance the use youmake of your equipments.
TrainingCompose your program fromthe numerous available modules,whether theoretical or practical,on air, vacuum and of course,the standard and regulatedenvironments for our products.
After-Sales ServiceFrom intervention on your premisesto servicing in our factories, fromtroubleshooting to maintenancecontract, our technicians will helpyou to maintain the performanceof your equipment and will counselyou on their optimisation.
Lending / RentingIf you want to checkout yourMIL'S technical solution beforecommitting yourself to a purchase,we can place by you, hired orloaned, the equipment you areinterested in.
Training
After-sales service
Lending / renting
Specifications are subject to be changed without notice
Dimensioning calculationand conversion tables
101
Specifications are subject to be changed without notice
MIL’S
Services
Dimensioning calculation Conversion tables
Flow rate calculation further to altitude
The after-specified formula allows to calculatethe pressure further to the altitude.Mind, this formula is valid up to 50 km altitude.
p = 1013 e –h / 7,5
with : p : pressure in hPah : altitude in km
Vacuum / Pressure
1 mbar = 0,0295 in Hg
1 bar = 14,50 psi
1 kPa = 10 mbar = 0,01 bar
Dimensions
1 mm = 0,039 in
1 m = 3,281 ft = 39,37 in
Power
1 kW = 1,341 hp
Weight
1 kg = 2,205 lb
Flow rate
1 m3.h-1 = 16,667 L.min-1 = 0,5886 cfm
1 L.min-1 = 0,2642 gal.min-1
Temperature
t(°F) = 1,8 x t(°C) + 32
Altitude (km) Pressure (hPa)At sea level 0 1013At Mont Blanc mountaintop 4,8 560At Everest mountaintop 8,8 320At average plane flight altitude 15 120
FLOW RATE
m3.h-1
PIPE LENGTH (m)
5 10 20 30 40 50 60 80 100
101525405060801001301802002503003404005006301000
1/2”
3/4”
1”
1”1/2
2”
2”1/2
3”
4”
1”1/4
Vacuum down grade time of a receiver
The following formula allows to calculate the required time todown grade of a receiver from P1 pressure to P2 pressure :
t = 2,3 (V / Q) log (P1 / P2)
with : V : receiver capacity in LQ : vacuum pump flow rate in L.s-1P1 : original pressure in absolute mbarP2 : final pressure in absolute mbart : evacuation time in s
102
General conditions of saleand guarantee - Sales contract
GENERAL POINTSThe orders noted and the commitments taken by theRepresentatives or Agents, are only binding on our companyafter its WRITTEN ACCEPTANCE.The orders only become final after forwarding of an ackno-wledgment of receipt. They imply the acceptance of the presentgeneral conditions of sale notwithstanding any contrary clausesof our customers that have not been expressly accepted inwriting.The role of our company consists in manufacturing the equip-ment. It is not for it to appreciate the appropriateness of thechoice of any equipment as regards its final destination or theuse to which it is allocated.Any information that we may be led to provide is only givenin the framework of our productions and for information, anddoes not consist of indications regarding the choice of theequipment or the final use for which it is destined. In no casecan our liability be incurred if there is no sale of equipment.Our activity consists in manufacturing products ordered byour customers and it is not for us to appreciate the appro-priateness of an order for the use to which it is destined bythe purchaser.The present general conditions and the special conditionsinsofar as the latter are not contrary to the present generalconditions and still comply with general contract law andcompetition law can be completed by the Customer generalconditions of purchase expressly accepted by the Supplier.Any derogation to the present general conditions is subject toour express and written acceptance.
TRANSFER OF OWNERSHIP – RESERVATION OF OWNERSHIPTRANSFER OF RISKThe merchandise shall remain our property up until the fullpayment of its price in principal and interest. Failing the pay-ment of the price on the agreed due date, we shall be able totake back the merchandise, the sale being declared void ifthis seems proper to us, and the deposits already paid shallremain acquired by us in return for the enjoyment of the mer-chandise from which the purchaser will have benefited.The purchaser becomes responsible for the merchandise as soonas it is collected from our factory, the transfer of possessionleading to the transfer of risks. The purchaser undertakes,consequently, to take out, as at present, an insurancecontract covering the risks of loss, theft or destruction of themerchandise.
INTELLECTUAL PROPERTY AND KNOW-HOWFOR DOCUMENTS AND PRODUCTSAll intellectual property rights as well as know-how incorporatedinto forwarded documents, delivered products and providedservices shall remain the exclusive property of our company.
STUDIES AND PROJECTSThe studies and documents of any nature passed on or sentremain entirely our property. They cannot lead to communicationor to execution by a third party.
CANCELLATION OF A CONFIRMED ORDERThe cancellation or termination of an order in the course ofexecution for a cause outside our control, including forcemajeure, shall render the customer the debtor in respect toMil’s of compensation that, in no case, shall be less than 20%of the amount of the order, whatever may be its state ofadvancement, and any deposit already paid shall be kept as cover.
RETURNSNo merchandise can be returned to the Company Mil’s withoutthe agreement of the latter.
DELIVERY AND PRICETHE DELIVERY IS DEEMED MADE IN OUR FACTORIES OR STORES.It is made by the direct handing-over to the customer, bysimple notice of availability, or by handing-over to a shipper orto a carrier appointed by the customer or, failing suchappointment, chosen by us.
The delivery times are given for information and are not gua-ranteed. Delivery delays do not give the purchaser the rightto cancel the sale or to refuse the merchandise. They cannot giverise to retention, compensation, penalty or damages.
THE PRICES ARE UNDERSTOOD TO EXCLUDE TAX FOR THEEQUIPMENT NOT PACKED TAKEN IN OUR FACTORIES OR STORES,THOSE PRICES ARE IN EUROS.
CONDITIONS OF USEAll equipment is delivered accompanied by technical instructionsthat we recommend should be followed. If these instructions arenot attached, they will be immediately forwarded on simplerequest.
PAYMENT CONDITIONIn case of no negotiation before ordering, the payment termis by swift transfer at reception of invoice, with minimum of60 € net. (Payments are made in euros unless otherwise sti-pulated in the agreement).It is expressly agreed and failing timely request for postponementand granted by us, the failure to pay our invoices by the dateindicated on the said invoices and by the date resulting from theapplication of our general sales conditions, if it is after the firstdate, shall lead to :
1. the immediate payability on the amounts remaining due,2. the interests calculated at a rate equal to 10% per year and
any legal costs.We do not grant discount for early payment, unless it hasbeen negotiated at the time of the order.
Notification of the customer situation :In case the deterioration of the customer situation is noticedby any means and/or certified by a significant delay in paymentor when the financial situation is appreciably different from theavailable data, the delivery will be made only in compensationfor an immediate payment.
TRANSPORTALL TRANSPORT OPERATIONS, insurance, customs, handlingcarried out ARE PAYABLE BY AND AT THE RISKS OF THE PUR-CHASER who is responsible for checking the shipments onarrival and for taking action, if appropriate, against the carriers.In the case of dispatch ensured by us, this shall be made car-riage due, full responsibility resting with the purchaser.Our company, at the request of the customer, shall insure themerchandise against transport risks, and shall invoice, as asupplement, the cost of this insurance.
GUARANTEE OF THE EQUIPMENTOUR MERCHANDISE IS GUARANTEED ONE YEAR, as from the dateIT IS MADE AVAILABLE, against any construction defect or anyfault in the material.In all cases, if the equipment is used by several teams, theperiod of the guarantee is necessarily reduced by half. For thecomponents that are not of our manufacture, we are not substi-tuted in the conditions of guarantee of the supplier constructor.
The guarantee does not apply to replacements or to repairs thatcould result from normal wear of the instruments, deteriorationor accidents due to a defect in surveillance or installation andimproper use. Likewise are excluded from the field of applicationof the guarantee, deteriorations resulting from damage duringtransport, falls, or violent shocks.The guarantee is limited to the free replacement, in ourworkshops, of the machine pieces or parts recognised asdefective due to material fault or manufacturing defect, with theexclusion of labour. The pieces replaced remain our property.
The transport costs, the outward as the return journey, are tobe paid by the customer.The guarantee ceases if the instruments are modified or repairedoutside our workshops. The passage through our workshops
does not lead to the extension of the period of initial guaranteeof the machine. Replacement parts or remade pieces areguaranteed 6 months, as from the delivery date after ourintervention. The guarantee shall not apply in the event ofnon-payment by the customer and he cannot take advantageof it or postpone his payments.
LOAN OF EQUIPMENTOur company may have to lend some material for a determinedduration under conditions defined in a loan contract. At the endof the agreed period, the customer shall notify if the materialon loan will be returned or ordered. In the absence of anynotification within this period, the sale shall be deemed tobe effective, as the customer will be presumed to have acceptedthe delivered product.
ELIMINATION OF WASTE“In accordance with article 18 of the decree N° 2005-829 ofJuly 20th, 2005 relating to the composition of the electricaland electronic equipment, the customer will be responsiblefor the financing and organisation of the elimination of wastefrom this equipment under the conditions defined in articles21 and 22 of the said decree. In case of control, the producermay ask his customer to send him the documents establishinghe fulfils, as regard this equipment, all the obligations trans-ferred with the sales contract.If the customer fails to forward these documents, he will bepresumed to be liable for non-fulfilment of the obligations heis responsible for and the manufacturer reserves the right toask him compensation for any damage that he could sufferthereby”.
INSURANCE COVERING OUR LIABILITYOur company has taken out an insurance policy covering thepecuniary consequences of our legal liability and this in thefollowing way :1. Before delivery of the products :
• Bodily injuries 6 100 000 €
• Consequential moral prejudice and damage to property1 530 000 €
with the exception of the following• Damage to entrusted goods 76 300 €
• Thef 30 500 €
• Non-consequential moral prejudice 305 000 €
2. After delivery of the products :• For all damage, combined single limit 1 530 000 €
without it being possible to exceed for the following damage :• Non-consequential moral prejudice, along with removing
and reinstalling costs 305 000 €
The fact of placing an order with us leads, on the part of ourcustomers, to the express acceptance of these limits to liabilityand to the abandon of the right to take legal action againstus for higher amounts.Of course, we remain at the disposal of our customers to takeout, the expenses to be borne by them, additional cover in theevent that they find our cover insufficient.
DISPUTESIn the case of disagreement relating to a delivery or its payment,the Lyon Commercial Court is the sole competent, whatevermay be the sales conditions and the method of payment chosen,even in the case of proceedings against the guarantor or morethan one defendant.
SPECIAL CONDITIONSThe special conditions and those that may be indicated in thedocumentations, quotes or prices forwarded only modify thesales conditions on the precise points to which they relate.The general sales and guarantee conditions of our companyare those accepted by the Fédération des IndustriesMécaniques et Transformatrices de Métaux (Federation ofMechanical Industries and Metal Transformers), on conditionthat they are not contrary to what precedes.The FIM professional business conditions are registered in theCommercial Court in Paris under N° 2005048625.
103
Notes
104
Notes
15 rue de Genève - 69746 Genas - Francetél. 33 (0)4 7278 00 40 - fax 33 (0)4 78 00 82 34
www.mils.eu - [email protected]
Phot
o cr
edits
: Co
pyrig
ht©
pho
todi
sc a
nd M
il’s
SAS
- Non
cont
ract
ual d
ocum
ents
and
pho
togr
aphs
bei
ng a
ble
to b
e m
odifi
ed w
ithou
t not
ice
- Con
cept
ion
Art
hési
s Co
mm
unic
atio
n 00
33
(0)4
72
59 0
0 00