+ All Categories
Transcript
Page 1: Model 3A76 Accessories & Options Action 2... · Adult Triple Action 2.0 Booster Spring Only Each Order No. Description UOM Booster Spring with multiple resist options Model 3A00-BS*

3A76-LATL

3A76-LATR

3A76-MEDL

3A76-MEDR

Adult Triple Action 2.0with Left Lateral Stirrup

Adult Triple Action 2.0with Right Lateral Stirrup

Adult Triple Action 2.0with Left Medial Stirrup

Adult Triple Action 2.0with Right Medial Stirrup

Each

Each

Each

Each

Order No. Description UOM

Product Data Sheet

Adult 2.0 Ankle Joint( 19mm Systems )

Patent Pending©2019 Becker Orthopedic Appliance Co., All rights reserved.Revision 5/1/19

800-521-2192 | 248-588-7480 800-923-2537 | 248-588-2960

BeckerOrthopedic.com

pf

Model 3A76Adult Triple Action® 2.0 ankle joint

Front View Side View

Standard(blue)

No Yes Yes Yes Yes

Standard(blue)

X1(low)

X2 (low/mod)

X3(mod)

X4(high)

X5(very high)

Booster Required

Bottom Spring

Top Spring

Stiffness

10° 10° 10° 10° 10°Max. ROM

High (silver)Standard

(blue)Standard

(blue)High

(silver)High

(silver)None

Standard(blue)

Standard(blue)

PIN Guide

1 2 3 4 5PF Spring Configuration

Accessories & Options

3A00-BS Adult Triple Action 2.0Booster Spring Only Each

Order No. Description UOM

Booster Spring with multiple resist options

Model 3A00-BS*

Lateral StirrupModels 3A76-LATR

& 3A76-LATL

Medial StirrupModels 3A76-MEDR

& 3A76-MEDL

FabricationTool Kit

Models 3A00-FTK

The fabrication tool kit includes fabrication dummies, alignment axis, attachment hardware and wrenches.

Alignment Scale

*Not available for sale in some countries

Page 2: Model 3A76 Accessories & Options Action 2... · Adult Triple Action 2.0 Booster Spring Only Each Order No. Description UOM Booster Spring with multiple resist options Model 3A00-BS*

The Adult Triple Action 2.0 (for 19mm Systems) is designed to provide highly adjustable active ankle control of the lower extremity during all phases of the gait cycle. The component excels in the orthotic treatment of complex disorders like stroke, traumatic brain injury and other pathologic neuromusculoskeletal conditions.

Ankle alignment, plantarflexion resist, dorsiflexion resist, and range of motion are independently adjustable to help simplify optimization. The clinician can easily tune the component to meet the changing needs of their patient through all stages of recovery and rehabilitation.

Triple Action provides multiple spring options, increased spring stiffness and spring durability. The component’s independent features are precisely adjustable to help mobilize the ankle and stabilize the knee.

The plantarflexion Booster Spring offers multiple high resistance spring options with a direct reading plantarflexion range of motion dial. Ankle alignment is also read directly from the component body simplifying adjustment and tracking for monitoring patient settings and progress.

± 10°

Spring 1 standard resistance

0° PF ROM corresponds to the locked (no range of motion in PF) ankle condition

with the adjustment screw or booster turned fully clockwise

ComponentSetting

AdjustmentRange Reference

0-10° PF ROM adjustment range•••

5° per turn of the adjustment screw or booster2 turns counter clockwise (10° maximum)

5 high stiffness spring options (No. 1 thru 5)

Ankle Alignment

Plantarflexion Spring Stiffness(with optional Booster

Spring, Model 3A00-BS)

Plantarflexion Spring Stiffness

(Model 3A76)

Plantarflexion Range of Motion

0° alignment corresponds to the corrected angle of the cast during

fabrication

Standard spring stiffness x1/x2/x3/x4/x5 depending on Booster

Spring configuration

Spring configuration 1 (included with Model 3A76 and 3A00-BS) is

suitable for the management of mild swing phase gait deficits

Specifications

IndicationsLower limb functional and structural deficits as a result of:

ContraindicationsPatient weight greater than 110 kg (240 lb)

Peroneal nerve palsyStrokeTraumatic brain injuryMultiple SclerosisPost Tendon transfer/repair surgeryAnkle contractureOther pathologic neuromusculoskeletal conditions

•••••••

Description

Patent Pending©2019 Becker Orthopedic Appliance Co., All rights reserved.Revision 5/1/19

800-521-2192 | 248-588-7480 800-923-2537 | 248-588-2960

BeckerOrthopedic.com

pf

Dimensions(3A76)

210mm(8.2in)

70mm(2.7in)

Product Data Sheet

Adult 2.0 Ankle Joint( 19mm Systems )

FeaturesIndependent adjustment of:

Multiple high stiffness plantarflexion spring options (with Booster Spring)

High mediolateral stability and smooth articulation in single upright composite AFO designs

Ankle alignmentPlantarflexion & dorsiflexion range of motionPlantarflexion spring stiffness (with Booster Spring)

•••

0° DF ROM corresponds to the locked (no range of motion in DF)

ankle condition

0-12° DF ROM adjustment range•••

3° per turn of the adjustment screw or booster4 turns counter clockwise (12° maximum)

Dorsiflexion Range of Motion

19mm(0.75in)