+ All Categories
Transcript

ProductSpecifications

Sarasota SG900Specific Gravity Analyzer

The Sarasota SG900 specific gravity

analyzer is designed for the high

accuracy measurement of gas specific

gravity/relative density (SG) or molecular

weight (MW). Used in wet or dry gas

applications, the Sarasota SG900 has

a key role in energy determination,

blending control, standard volume

(mass) flow calculation and fuel gas

monitoring to ensure process optimization

and environmental compliance within

the oil and gas, petrochemical,

chemical, and power industries.

Analyze • Detect • Measure • ControlTMFormerly Thermo Measurement

Gas specific gravity (SG) measurementapplications such as fuel gas monitoringand energy determination requirecontinuous, high accuracy measurements toensure maximum efficiency and minimumwastage. Fast response is critical to ensureeffective burner, furnace or flare gasmonitoring and control.

Thermo Electron Corporation’s SarasotaSG900 specific gravity analyzer is recommendedin applications where specific gravity (SG) or molecular weight (MW) can be used toinfer density elsewhere in the plant, andwhere the gas is dirty or wet and requiresfiltering prior to the measurement.

The Sarasota SG900 is available in threestandard configurations to suit theapplication—the basic system, a dry gassystem, and a wet gas system. Specificconfiguration requirements may also beaccommodated within the systems if needed.

Housed in a weatherproof enclosure, the basic Sarasota SG900 system comprisesa Sarasota FD792 gas density assembly,temperature element, and flow controlvalve. All components are interconnected by 6 mm (0.24 in) stainless steel tubing. Thebasic system is ideal for applications wherethe analyzer is used in conjunction with anexisting gas conditioning system thatprovides a clean, dry sample at a pressurebelow 4 bar A (58 psi A).

Applications• Gas blending control• Standard volume flow control• Refinery fuel gas monitoring (CV estimate)• Oven/furnace gas monitoring (CV estimate)• Flare control systems (MW monitoring)

Features• Accurate to 0.2% reading above

0.5 SG at reference conditions• User selectable reference conditions• Integral sample conditioning• Options to suit dry or wet gas applications• Hazardous area use• Rugged construction for harsh environments• No on-site calibration required

SarasotaSG

900Specific

Gravity

Analyzer

In applications where the gas is alwaysabove its dew point, but the sample is notfiltered and the pressure not controlled, aspecific ‘dry gas’ configuration is available.This is similar to the basic system, but withan inlet pressure regulator, particulate filter,safety vent, calibration point, sampleflowmeter, flow control needle valve, and isolation valves.

Gas streams with a possibility of significantmoisture content require the ‘wet gas’ systemwhich is based on the dry gas system but with the addition of a coalescing filterand auto drain.

To maintain the measurement systemabove the gas dew point and to giveadditional repeatability, an optional steamor electric heater may be mounted withinthe enclosure.

Signal outputs from the transducers maybe fed to a Sarasota CM200 control roommounted density converter. Alternatively,the Sarasota HME900 field mounted densityconverter option provides a direct HART®

compatible output. Designed for use within harsh environments,

the Sarasota SG900 requires minimalmaintenance. Whilst regular checks on component parts are recommended, the frequency of maintenance depends upon the operating conditions.

600 mm(23.6 in)

300 mm(11.8 in)

30 mm(1.18 in)

100 mm(3.94 in)

620 mm(24.4 in)

Filter Assembly*

Autodrain Assembly*

Flowmeter Assembly*

Pressure Regulator*

Isolating Valve*

Isolating Valve

PRT Assembly

EExd Heater Terminal Box*

EExd Heater*

Density Meter PRT (RTD) &Pressure Terminal Box

Flow Out

Drain*

Calibration Gas Inlet*

Safety Vent*

Bulkhead Pipe Fitting

Flow In

Density Meter Assembly

*Optional Components

Ø8.5 mm (Ø0.33 in)

GRP Enclosure

Conduit

Isloating Valve*

High Pressure Isolating Valve*

Pressure Relief Valve

Pressure Transmitter

Flow Control Valve

800 mm(31.5 in)

727 mm(28.6 in)

Sarasota SG900 Specific Gravity Analyzer — Dimensional Diagram

SpecificationD

rawings

Ordering

Information

MODEL NUMBERSG900: Sarasota Specific Gravity Analyzer

SYSTEMTYPE

MO

DEL

NU

MB

ER

INTERN

AL

HEATER

SIGN

AL

OU

TPUT

SG900 A B C

SPOO

LM

ATERIAL

D

CERTIFICATION

OPTIO

NS

E F

A. SIGNAL OUTPUTF: Frequency outputH: Smart headmounted electronics

B. SYSTEM TYPEB: Basic systemD: Dry gasW: Wet gas

C. INTERNAL HEATERO: No internal heaterE: Electrical heaterS: Steam heater

D. SPOOL MATERIALZ: Ni-Span CY: FV520B

E. CERTIFICATIONS: Non-hazardous / safe area applicationI: Intrinsically safe / flameproof (if heater fitted)

F. OPTIONSL: Local display (headmounted version only)M: Wetted parts traceability certification to BS EN 10204.3.12.bN: BS EN ISO 15156 / NACE MR0175 conformance certificationT: Traceable calibration equipment listingW: WinHME900 communication software and modem (headmounted versions only)

NOTE: Consult your Thermo representative for details of maintenance contracts and additional services including installation, commissioning, re-calibration, service and repair

FLOW200

100

40

R

%

425

300

OUTPUT %

No.

ONLY

600 mm(23.6 in)

300 mm(11.8 in)

30 mm(1.18 in)

100 mm(3.94 in)

620 mm(24.4 in)

Filter Assembly

Flowmeter Assembly

Pressure Regulator

Ball Valve Assembly

Flow Out

Calibration Gas Inlet

Safety Vent

Flow In

Density Meter Assembly

Pressure Transmitter

Ø8.5 mm (Ø0.33 in)

GRP Enclosure Wall Fixing Lugs

High Pressure Isolating Valve

Pressure Release Valve

Ball Valve Assembly

Flow Control Valve

800 mm(31.5 in)

727 mm(28.6 in)

Sarasota SG900 Specific Gravity Analyzer with Sarasota HME900 Density Converter — Dimensional Diagram