+ All Categories
Transcript
Page 1: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The higher the MPR, the more microparticles—such as pollen, pet dander, smoke, bacteria and viruses—your filter will capture from the air passing through it.

TABLE OF CONTENTS

MERVMPRMicroparticle Performance Rating Minimum E�ciency Reporting Value

VS

MPR 300 vs MERV 5 02

MPR 600 vs MERV 7 03

MPR 1000 vs MERV 11 04

MPR 1200 vs MERV 11 05

MPR 1500 vs MERV 12 06

MPR 1900 vs MERV 13 07

MPR 2200 vs MERV 13 08

MPR 2500 vs MERV 14 09

MPR 2800 vs MERV 14 10

01Reasonable capture rate based on Minimum E�ciency Capture.

Page 2: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 300 Minimum capture rate of E1, E2, E3 particles

12%

38%

34%

E1E2

E3

MERV 5Minimum capture rate of E1, E2, E3 particles

n/a

n/a

20%

E1

E2

E3

MERV 13Filter

MERV 5FILTER

02

Page 3: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 600 Minimum capture rate of E1, E2, E3 particles

MERV 7Minimum capture rate of E1, E2, E3 particles

23%

54%

55%

E1

E2

E3

n/a

n/a

50%

E1

E2

E3

MERV 13Filter

MERV 7FILTER

03

Page 4: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 1000 Minimum capture rate of E1, E2, E3 particles

MERV 11Minimum capture rate of E1, E2, E3 particles

41%

77%

88%

E1

E2

E3

20%

65%

85%

MERV 13Filter

E1

E2

E3

MERV 11FILTER

04

Page 5: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 1200 Odor Minimum capture rate of E1, E2, E3 particles

MERV 11Minimum capture rate of E1, E2, E3 particles

20%

65%

85%

MERV 13Filter

E1

E2

E3

MERV 11FILTER

43%

78%

88%

E1

E2

E3 +Odor

05

Page 6: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 1500 Minimum capture rate of E1, E2, E3 particles

MERV 12Minimum capture rate of E1, E2, E3 particles

35%

80%

90%

MERV 13Filter

E1

E2

E3

MERV 12FILTER

54%

83%

90%

E1

E2

E3

06

Page 7: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 1900 Minimum capture rate of E1, E2, E3 particles

MERV 13Minimum capture rate of E1, E2, E3 particles

50%

85%

90%

MERV 13Filter

E1

E2

E3

MERV 13FILTER

62%

87%

95%

E1

E2

E3

07

Page 8: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 2200 Minimum capture rate of E1, E2, E3 particles

MERV 13Minimum capture rate of E1, E2, E3 particles

50%

85%

90%

MERV 13Filter

E1

E2

E3

MERV 13FILTER

69%

90%

96%

E1

E2

E3

08

Page 9: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 2500 Minimum capture rate of E1, E2, E3 particles

MERV 14Minimum capture rate of E1, E2, E3 particles

75%

90%

95%

MERV 13Filter

E1

E2

E3

MERV 14FILTER

77%

93%

97%

E1

E2

E3

2500

09

Page 10: MPR (Microparticle Performance Rating) indicates its ...MPR (Microparticle Performance Rating) indicates its ability to capture tiny particles between 0.3 and 1 micron in size. The

MPR 2800 Minimum capture rate of E1, E2, E3 particles

MERV 14Minimum capture rate of E1, E2, E3 particles

75%

90%

95%

MERV 13Filter

E1

E2

E3

MERV 14FILTER

81%

94%

97%

E1E2

E3

10