NaviSuite Nardoa Offline Training (Pipeline Inspection)
NaviEdit – NaviModel - NaviPlot
Training Schedule:
Day 1: IntroductionInstallation of SoftwareNaviEdit
Day 2: NaviEdit (Continued)Patchtest CalibrationNaviModel
Day 3: NaviModel (Continued)Day 4: NaviModel PipeDay 5: NaviModel Pipe
NaviPlot
Scope of NaviSuite Offline Nardoa Training (Pipe)Learning Objectives: The course is structured around a dedicated yet general curriculum with the aim being to furnish the trainees with a broad understanding of the EIVA NaviSuite offline software solutions and make them confident in using these software solutions in post-processing situations. The primary focus of the course is post-processing of pipeline inspection data. To enhance trainee competence and confidence, a wide range of typical pipeline-based hydrographic survey data, acquired using the EIVA NaviSuite online software solutions, is used to exemplify typical pipe based post-processing scenarios. For the most part, the course is conducted as hands-on training.
By the end of the course, trainees will be able to:
Install the relevant NaviSuite software solutions Understand the basic architecture of NaviEdit, NaviModel and NaviPlot Conduct editing of multi-beam and single beam data in a NaviEdit/NaviModel environment Conduct a patch test calibration in NaviModel/NaviEdit Use the S-CAN automatic cleaning tool Use the various DTM tools in NaviModel Conduct volume and area calculations in NaviModel Understand the concept of video integration in NaviModel Use the pipeline inspection tools in NaviModel Export data from NaviModel using generic as well as built-in tools Create simple plots in NaviPlot Create alignment sheets in NaviPlot using the Chart Layout Manager
Target Group: The course is aimed towards surveyors with some experience of offshore survey work and with a basic knowledge of hydrographic surveying.
Entry Level: Prior knowledge of the EIVA software solutions is recommended. The language of instruction in the course is English.
Duration: The duration of the course is 5 days, from 9 A.M. to 4 P.M., including breaks.
Completion: Upon completion, a dedicated EIVA Training Certificate will be issued.
Scope of the Offline Course
Training Curriculum I:Introduction:• The Company, EIVA• Download and Knowledgebase• The Training Site
NaviEdit:• Installation of NaviEdit• SQL-Server• Database Management• Importing of Data• The Header Editor• The Data Editor• The PlanView Editor• Batch Editing• Exporting Data
Patchtesting within NaviModel:• Installation of NaviModel• Patchtest Theory:
• Calibration Sequence• Latency Calibration• Pitch Calibration• Roll Calibration• Heading Calibration
• Training with Data• Utilizing the Results:
• Within NaviScan• Within NaviEdit
Training Curriculum II:
NaviModel (Continued): • Using Toppings:
• Runlines• Displaylines• Waypoints• AutoCAD-files• CDF-series• Esri files etc.
• Contours:• Filled Contours• Live Contours
• Digitizing Methods• Exporting Funtionalities:• Generic Exporter• Area Export
• Volume and Area Calculations• Online 3D Visualisation
NaviModel: • General Layout of NM3• Model Types (TRN & TIN)• Interpolation Methods (IDW & TIN)• The Quad Tree Principle• Indexing a DTM• Raw Data View• Cleaning Methods:
• Automatic Cleaning Methods• S-CAN Score• S-CAN Components
• Manual Cleaning Methods• Point Edit Cleaning• Histogram Plane Cleaning• Spike Shooting Cleaning
Training Curriculum III:
NaviPlot:• Installation of NaviPlot• Creating Frames• Generating Templates• Using the Lay-out Manager• Adding XY-data to a Frame:• Contours & TIN Contours• Bathy Plot• Runlines, Display Lines• DXF / DWG Files • Profiles (long- and crossprofiles)• Events and Waypoints• Coverage• AutoCad• Trackplot• Chart Definition Files
NaviModel Pipe: • The Pipe Object• Pipetracker Data• Digitizing the Pipe
• Manual Digitization• Autoplacing the Pipe
• Runline Information• Generating the Pipe Object• Modifying the Pipe• Creating Sideflags• Using the Sideflags
• Video Integration• Offline Eventing• Exporting Freespans and Burials• Pipe Listings
Training Curriculum IV:NaviPlot (Continued):• Adding Profiles to a Frame:• Longitudinal Profiles• Cross Profiles• NPD Profile• Fix profile• Event Profiles• KP Alignment Sheets
• Adding Bitmaps to a Frame• Adding Text to a Frame:• Using Tagged Text
• Printing and Plotting• Exporting to AutoCAD (DXF/DWG)• Zipping an NP-Project• Saving in IHO S-57 format
Download & KnowledgebaseThe EIVA Downloadsite gives users thepossibility todownload latestversions andpatches of thevarious softwarepackages.
A user can sign upfor login accessand cansubsequentlyreceive an e-mailnotification whenreleases occur onthe various folders.
In the Knowledgebase, FAQ from theEIVA user community, are listed andorganized relative subjective items like:software package, popularity, age (latestaddition) etc.
Users are also given the opportunity tosubmit a question that will then beupgraded and included in theknowledgebase.
Training & Documentation SiteThe Training & Documentation sitecontains all documentation and trainingmaterial associated with the EIVA Soft-and Hardware. It should therefore beinstalled whenever installing the EIVAsoftware (is not a requirement for theproper functioning of the associatedsoftware.
The documentation includes all on-linehelp, manuals, powerpoints, reports,papers, training documents available forthe EIVA software packages as well asfor the EIVA hardware.
The site is designed to be executed inoff-line mode (with no connection to theInternet), however some of the itemswill only provide optimum functionality ifan Internet connection has beenestablished. Observe that the site canalso be reached at the EIVA Website
http://download.eiva.dk/online-training/index.htm
Training & Documentation Site IIThe Training & Documentationsite is subdivided into subpagesthat relate to the differentmodules that constitute EIVANaviSuite.
The Offline packages havethree subpages, related to:
• NaviEdit
• NaviModel (shown here)
• NaviPlot.
The Software Installer lists thesoftware packages in thesequence shown to the left.
During installation, alwaysremember to use defaultsettings.
Software Installation
The EIVA Offline Flow
The NaviEdit Flow
NaviEdit JobPlanner
NaviModel Patch Testing
Patch Testing can be performed in NaviModel and in the Online3D application. In the latter case, no dongleis required.
A multibeam Patch Test calibration serves a dual purpose:a. To determine the mount angles of the multibeam transducer
relative to the three axes of the local coordinate system of the vessel/ROV. These three figures are often referred to as the roll-, pitch- and heading mount angles.
b. To confirm the relationship between the time-tagging on the multibeam data and the time-tagging on the position data. This figure is often referred to as the latency or as the time value.
Patch Test – Purpose of the Calibration
The NaviModel Pipe Flow
NaviModel - I
NaviModel – IIThe QuadTree Principle
• TRN Geometry Type:• Square cells divided into four triangles each• To ensure a smooth transition between cells
NaviModel – IIIGeometry Types - I
• The TIN geometry type:• TIN Model, left• Delaunay Triangulation, principle, right (circumcised circles between corners of
triangles must not contain other points)
NaviModel – IVGeometry Types - II
NaviModel – VInterpolation
NaviModel – VI
The NaviPlot Flow
NaviPlot - I
NaviPlot - II