NEK 606 Offshore & Marine Cables
NEK606 STANDARD
www.caledonian-cables.co.ukwww.addison-cables.ccom
Caledonian
UNITED KINGDOM
Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UKTel: 44 (0) 207 419 5087Fax: 44 (0) 207 831 9489Email: [email protected]
HONG KONG
Unit B 22/F CMA Building, 64-66 Connaught Road Central, Hong KongTel: 852 36527508Fax: 852 35834834Email: [email protected]
Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application.
Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard, ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia.
Caledonian & Addison, produces a wide range of cables for communication, power and electronics in its primary plants in UK, Italy and Spain. To stay in front, we continually keep expanding our manufacturing capabilities in more low cost region such as Romania, Taiwan, Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible, scalable global system that delivers superior operational performance and optimal results for our customers.
Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing, logistic services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market.
Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning, we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.
Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian & Addison has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.
1ADDISONwww.addison-cables.com
P1 or P1/P8 RFOU/TFOU 0.6/1KV .......................................................................3P18 RU 0.6/1kV ....................................................................................................8P15 UX 0.6/1kV ..................................................................................................12
CONTENT
Medium Voltage Power Cables
Fire Resistant Power and Control Cables
Fire Resistant Medium Voltage Power Cables
Instrumentation Cables
P5 or P5/P12 BFOU 0.6/1KV ..............................................................................14P17 BU 0.6/1 kV .................................................................................................19P34 BFOU-HCF 0.6/1 kV ....................................................................................23
P2 or P2/P9 RFOU/TFOU 3.6/6KV ....................................................................26P3 or P3/P10 RFOU/TFOU 6/10KV ....................................................................29P4 or P4/P11 RFOU/TFOU 8.7/15KV .................................................................32P19 or P19/P21 RFOU 12/20KV ........................................................................35
P6 or P6/P13 BFOU 3.6/6kV ..............................................................................38P7 or P7/P14 BFOU 6/10kV ..............................................................................41P30 RFOU-HCF / TFOU-HCF 6/10(12) kV .........................................................44
S1 or S1/S5 RFOU(i) 250V .................................................................................47S2 or S2/S6 RFOU(c) 250V ................................................................................53P16 IFLI 250 V ...................................................................................................59S11 RU(i) 250 V ..................................................................................................61S12 RU(c) 250 V .................................................................................................64
Fire Resistant Instrumention Cables
S3 or S3/S7 BFOU(i) 250V .................................................................................67S4 or S4/S8 BFOU(c) 250V ................................................................................73S13 BU(i) 250 V .................................................................................................79
Power and Control Cables
Power and Control Cables
2 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
RG6 Armoured Coaxial Cable ..........................................................................105RG11 Armoured Coaxial Cable .........................................................................107RG59 Armoured Coaxial Cable ........................................................................109RG58 Armoured Coaxial Cable ........................................................................ 111RG213 Armoured Coaxial Cable ...................................................................... 113Mud Resistant Composite Cable ...................................................................... 115
Telecommunication Cables
Data Cables
Coaxial Cables
S9 IYXI(c) 60 V ...................................................................................................89S10 IYOI(c) 60 V .................................................................................................91
S14 BU(c) 250 V ................................................................................................82S15 BFOU-HCF(i) 250 V ...................................................................................85S16 BFOU-HCF(c) 250 V ..................................................................................87
F1 QFCI .............................................................................................................93F5 QFCB ............................................................................................................95F6 AICI ...............................................................................................................97
Cat5E UTP/FTP Armoured Data Cable ..............................................................99Cat6 UTP/FTP Armoured Data Cable ...............................................................102
Cable Code Designation ................................................................................... 117Standards and Tests ................................................................................ 118Cable Characteristics ....................................................................................... 119Electrical Data ...................................................................................................121Core Identification ............................................................................................123
Technical Information
Optical Fibre Cables
Power and Control Cables
3ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P1 or P1/P8 RFOU/TFOU 0.6/1KV
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for control, power and lighting systems.
Standards
IEC 60092-353
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Tinned annealed stranded copper to IEC 60228 class 2. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable)Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P1). Halogen free, mud resistant thermosetting compound, SHF MUD (for TYPE P1/P8), coloured black.
Electrical Characteristics
Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35 50 70Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4.0 5.1 6.5 7.4 8.7 10.3Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391 0.27Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157 196 242
Copper Wire Braid
Halogen Free EPR/XLPE Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF2/SHF MUD Sheath
Power and Control Cables
4 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133 167 206
Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110 137 169
Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010 7150 10020Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Nominal Cross Section Area mm² 95 120 150 185 240 300 400 500 630Nominal Conductor Diameter mm 12.2 13.8 15.1 17.0 19.6 21.9 24.6 27.6 32.5Maximum DC Resistant@20℃ Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 293 339 389 444 522 601 690 780 890Continuous Current Rating@45℃ 2 Core A 249 288 331 444 444 511 587 663 757Continuous Current Rating@45℃ 3&4 Core A 205 237 272 311 365 421 483 546 623
Short Circuit Current 1s A 13590 17170 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1
3= ), I1= Current rating for 1-core, N = Number of cores.
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×1.5 1.0 1.1 1.1 8.9 1351×2.5 1.0 1.1 1.1 9.3 1501×4 1.0 1.1 1.1 9.9 1801×6 1.0 1.1 1.1 10.4 2051×10 1.0 1.1 1.2 12.2 2951×16 1.0 1.1 1.2 13.5 385
Power and Control Cables
5ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Beddingmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×25 1.2 1.1 1.2 15.4 5251×35 1.2 1.1 1.3 16.9 6851×50 1.4 1.1 1.4 18.7 8701×70 1.4 1.1 1.4 20.4 11051×95 1.6 1.1 1.5 22.8 1435
1×120 1.6 1.2 1.6 24.9 17451×150 1.8 1.2 1.6 26.8 20551×185 2.0 1.2 1.7 29.3 25601×240 2.2 1.2 1.8 32.5 31901×300 2.4 1.2 1.9 35.2 39351×400 2.4 1.4 2.1 40.5 50601×500 2.4 1.4 2.2 44.0 61801×630 2.4 1.4 2.3 48.0 76202×1.5 1.0 1.1 1.2 13.6 2952×2.5 1.0 1.1 1.2 14.4 3352×4 1.0 1.1 1.3 16.1 4452×6 1.0 1.1 1.3 17.1 520
2×10 1.0 1.1 1.4 19.3 6802×16 1.0 1.1 1.5 21.7 9552×25 1.2 1.2 1.6 25.9 13352×35 1.2 1.2 1.7 27.9 15952×50 1.4 1.2 1.9 31.9 22502×70 1.4 1.2 2.1 35.8 27952×95 1.6 1.2 2.3 41.2 3780
2×120 1.6 1.4 2.4 44.8 45602×150 1.8 1.4 2.6 49.2 55002×185 2.0 1.4 2.7 53.8 66752×240 2.2 1.6 3.0 61.0 86052×300 2.4 1.6 3.2 67.0 105103×1.5 1.0 1.1 1.2 14.2 3203×2.5 1.0 1.1 1.3 15.6 4153×4 1.0 1.1 1.3 16.8 5003×6 1.0 1.1 1.4 18.1 605
3×10 1.0 1.1 1.4 20.3 7953×16 1.0 1.1 1.5 22.8 11253×25 1.2 1.2 1.6 27.5 16203×35 1.2 1.2 1.7 29.6 19553×50 1.4 1.2 1.9 33.9 27303×70 1.4 1.4 2.0 38.4 36553×95 1.6 1.4 2.2 43.8 4885
Power and Control Cables
6 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Beddingmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
3×120 1.6 1.4 2.3 47.6 60003×150 1.8 1.6 2.5 52.4 73003×185 2.0 1.6 2.7 58.6 89603×240 2.2 1.8 2.9 66.1 116103×300 2.2 1.8 3.4 71.9 134904×1.5 1.0 1.1 1.3 15.7 3504×2.5 1.0 1.1 1.3 16.6 4254×4 1.0 1.1 1.4 18.1 5904×6 1.0 1.1 1.4 19.5 725
4×10 1.0 1.1 1.5 22.1 9554×16 1.0 1.2 1.6 25.2 13754×25 1.2 1.2 1.7 30.0 19654×35 1.2 1.2 1.8 32.4 24104×50 1.4 1.4 2.0 37.3 33654×70 1.4 1.4 2.2 42.1 45804×95 1.6 1.4 2.4 48.2 6020
4×120 1.6 1.6 2.5 52.7 74404×150 1.8 1.6 2.9 58.3 88004×185 2.0 1.6 3.1 64.0 107604×240 2.2 1.8 3.4 72.4 138904×300 2.4 1.8 3.7 79.8 174055×1.5 1.0 1.1 1.3 16.7 4206×1.5 1.0 1.1 1.3 17.8 4957×1.5 1.0 1.1 1.3 17.8 5408×1.5 1.0 1.1 1.5 20.3 6459×1.5 1.0 1.1 1.5 21.5 67510×1.5 1.0 1.1 1.5 21.8 70512×1.5 1.0 1.1 1.5 22.5 80514×1.5 1.0 1.1 1.6 23.6 86016×1.5 1.0 1.1 1.7 24.9 94019×1.5 1.0 1.1 1.7 26.0 110020×1.5 1.0 1.1 1.7 27.2 113023×1.5 1.0 1.1 1.8 29.3 128524×1.5 1.0 1.1 1.8 30.0 130527×1.5 1.0 1.1 1.9 30.8 146030×1.5 1.0 1.1 1.9 31.8 152033×1.5 1.0 1.2 2.0 33.5 167037×1.5 1.0 1.2 2.0 34.6 184044×1.5 1.0 1.2 2.2 39.2 22105×2.5 1.0 1.1 1.4 18.0 555
Power and Control Cables
7ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Beddingmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
6×2.5 1.0 1.1 1.4 19.2 5907×2.5 1.0 1.1 1.4 19.2 6558×2.5 1.0 1.1 1.5 21.8 7759×2.5 1.0 1.1 1.6 23.3 78510×2.5 1.0 1.1 1.6 23.6 86512×2.5 1.0 1.1 1.6 24.5 95514×2.5 1.0 1.1 1.7 25.5 107016×2.5 1.0 1.1 1.7 26.7 115519×2.5 1.0 1.1 1.8 28.2 136020×2.5 1.0 1.1 1.8 29.5 141023×2.5 1.0 1.1 1.9 31.8 161024×2.5 1.0 1.2 2.0 33.2 169027×2.5 1.0 1.2 2.0 33.9 181530×2.5 1.0 1.2 2.0 34.9 196033×2.5 1.0 1.2 2.1 36.7 219037×2.5 1.0 1.2 2.1 38.0 237044×2.5 1.0 1.2 2.3 42.6 2795
Power and Control Cables
8 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P18 RU 0.6/1kV
Applications
These cables are flame retardant, low smoke and halogen free, used for control, power and lighting systems.
Standards
IEC 60092-353
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Tinned annealed stranded copper to IEC 60228 class 2. Insulation: Halogen-free EPR.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured black.
Electrical Characteristics
Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110
Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Halogen Free EPR Insulation
Stranded Copper Conductor
SHF2 Sheath
Power and Control Cables
9ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Nominal Cross Section Area mm² 50 70 95 120 150 185 240 300Nominal Conductor Diameter mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 196 242 293 339 389 444 522 601Continuous Current Rating@45℃ 2 Core A 167 206 249 288 331 444 444 511Continuous Current Rating@45℃ 3&4 Core A 137 169 205 237 272 311 365 421Short Circuit Current 1s A 7150 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1
3= ), I1= Current rating for 1-core, N = Number of cores.
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×1.5 1.0 1.0 6.0 601×2.5 1.0 1.0 6.5 801×4 1.0 1.0 7.1 1101×6 1.0 1.0 7.6 1301×10 1.0 1.1 8.5 1651×16 1.0 1.1 9.8 2351×25 1.2 1.2 11.7 3551×35 1.2 1.2 12.8 4551×50 1.4 1.3 14.4 5951×70 1.4 1.4 16.3 8051×95 1.6 1.5 18.7 10901×120 1.6 1.5 20.3 13451×150 1.8 1.6 22.4 16351×185 2.0 1.7 24.9 2075
Power and Control Cables
10 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×240 2.2 1.8 28.1 26601×300 2.4 1.9 30.8 33402×1.5 1.0 1.1 9.7 1452×2.5 1.0 1.1 10.5 1752×4 1.0 1.2 11.6 2252×6 1.0 1.2 12.9 2952×10 1.0 1.3 14.8 4202×16 1.0 1.4 17.2 6052×25 1.2 1.5 21.3 9402×35 1.2 1.6 23.3 11852×50 1.4 1.8 26.9 15852×70 1.4 1.9 31.9 22802×95 1.6 2.1 36.9 30902×120 1.6 2.2 40.3 37802×150 1.8 2.4 44.7 46402×185 2.0 2.6 49.5 57502×240 2.2 2.8 56.1 74602×300 2.4 3.0 62.0 92653×1.5 1.0 1.1 10.3 1653×2.5 1.0 1.2 11.1 2053×4 1.0 1.2 12.5 2803×6 1.0 1.3 13.6 3603×10 1.0 1.3 16.0 5303×16 1.0 1.4 18.5 7703×25 1.2 1.6 22.9 12003×35 1.2 1.7 25.0 15253×50 1.4 1.8 28.7 20303×70 1.4 2.0 32.6 27653×95 1.6 2.2 37.6 37453×120 1.6 2.3 41.2 46403×150 1.8 2.5 45.7 56753×185 2.0 2.7 51.2 72003×240 2.2 3.0 57.5 93003×300 2.4 3.2 66.8 120804×1.5 1.0 1.2 11.2 2004×2.5 1.0 1.2 12.4 2554×4 1.0 1.3 13.7 3404×6 1.0 1.3 15.2 4554×10 1.0 1.4 17.5 6654×16 1.0 1.5 20.4 9704×25 1.2 1.7 25.5 15304×35 1.2 1.8 27.8 19554×50 1.4 2.0 31.9 2600
Power and Control Cables
11ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
4×70 1.4 2.1 36.3 35404×95 1.6 2.4 42.0 48154×120 1.6 2.5 46.0 59654×150 1.8 2.7 53.5 77204×185 2.0 2.9 59.2 95704×240 2.2 3.2 67.3 124804×300 2.4 3.5 74.6 158705×1.5 1.0 1.2 13.1 2456×1.5 1.0 1.3 14.4 2757×1.5 1.0 1.3 14.4 2858×1.5 1.0 1.4 16.9 3809×1.5 1.0 1.4 18.1 39510×1.5 1.0 1.4 18.4 43512×1.5 1.0 1.4 19.0 48514×1.5 1.0 1.5 20.2 56516×1.5 1.0 1.5 21.3 61519×1.5 1.0 1.6 22.6 71520×1.5 1.0 1.6 23.8 78023×1.5 1.0 1.7 25.9 90524×1.5 1.0 1.7 26.6 92027×1.5 1.0 1.7 27.2 98530×1.5 1.0 1.8 28.4 111033×1.5 1.0 1.8 29.5 119037×1.5 1.0 1.9 30.8 131544×1.5 1.0 2.0 34.8 15605×2.5 1.0 1.3 14.3 3056×2.5 1.0 1.3 15.6 3607×2.5 1.0 1.3 15.6 3908×2.5 1.0 1.4 18.4 4959×2.5 1.0 1.5 19.9 50510×2.5 1.0 1.5 20.2 57012×2.5 1.0 1.5 20.9 62514×2.5 1.0 1.5 21.9 73516×2.5 1.0 1.6 23.3 81019×2.5 1.0 1.6 24.6 93520×2.5 1.0 1.7 26.1 103523×2.5 1.0 1.8 28.4 120524×2.5 1.0 1.8 29.2 122027×2.5 1.0 1.8 29.9 129530×2.5 1.0 1.9 31.1 147533×2.5 1.0 1.9 32.3 158537×2.5 1.0 2.0 33.8 173044×2.5 1.0 2.2 38.4 2100
Power and Control Cables
12 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P15 UX 0.6/1kV
Applications
These cables are flame retardant, low smoke and halogen free, used for earthing and bonding services.
Standards
IEC 60092-353
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Tinned annealed stranded copper to IEC 60228 class 2 or class 5. Insulation: Halogen free thermosetting compound, SHF2. When used as protective earth (PE) wire, the cables coloured yellow/green. When used as single wire, the cables coloured off-white, black, red or blue.
Electrical Characteristics
Nominal Cross Section Area mm² 10 16 25 35 50 70Nominal Conductor Diameter mm 4 5.1 6.5 7.4 8.7 10.3Maximum DC Resistant@20℃ Ω/km 1.84 1.16 0.734 0.529 0.391 0.27Continuous Current Rating@45℃ 1 Core A 72 96 127 157 196 242Short Circuit Current 1s A 1430 2290 3580 5010 7150 10020Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Nominal Cross Section Area mm² 95 120 150 185 240 300Nominal Conductor Diameter mm 12.2 13.8 15.1 17.0 19.6 21.9
SHF2 Insulation
Stranded Copper Conductor
Power and Control Cables
13ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Maximum DC Resistant@20℃ Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 293 339 389 444 522 601Short Circuit Current 1s A 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thicknessmm
Nominal Overall Diametermm
Nominal Weightkg/km
1×10 1.0 6.6 125
1×16 1.0 7.7 185
1×25 1.2 9.5 290
1×35 1.2 10.4 380
1×50 1.4 12.1 510
1×70 1.4 13.6 700
1×95 1.6 15.5 950
1×120 1.6 17.5 1205
1×150 1.8 19.4 1470
1×185 2.0 21.7 1875
1×240 2.2 24.7 2420
1×300 2.4 27.2 3060
Fire Resistant Power and Control Cables
14 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P5 or P5/P12 BFOU 0.6/1KV
Applications
These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for control, power and lighting systems.
Standards
IEC 60092-353
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Tinned annealed stranded compacted copper to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR/Mica tape + XLPE.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P5). Halogen free, mud resistant thermosetting compound, SHF MUD (for TYPE P5/P12), coloured black.
Electrical Characteristics
Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35 50Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4 8.7Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391
Copper Wire Braid
Mica Tape + HFEPR/XLPE Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF2/SHF MUD Sheath
Fire Resistant Power and Control Cables
15ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157 196Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133 167Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110 137
Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010 7150Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Nominal Cross Section Area mm² 70 95 120 150 185 240 300 400 630
Nominal Conductor Diameter mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9 24.6 32.5
Maximum DC Resistant@20℃ Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0286
Continuous Current Rating@45℃ 1 Core A 242 293 339 389 444 522 601 690 890Continuous Current Rating@45℃ 2 Core A 206 249 288 331 444 444 511 587 757Continuous Current Rating@45℃ 3&4 Core A 169 205 237 272 311 365 421 483 623
Short Circuit Current 1s A 10020 13590 17170 21460 26470 34340 42930 57230 90140Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1
3= ), I1= Current rating for 1-core, N = Number of cores.
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×1.5 1.0 1.1 1.1 9.3 1451×2.5 1.0 1.1 1.1 9.7 1601×4 1.0 1.1 1.1 10.4 2201×6 1.0 1.1 1.1 10.9 2501×10 1.0 1.1 1.2 12.7 310
Fire Resistant Power and Control Cables
16 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×16 1.0 1.1 1.2 13.9 3901×25 1.2 1.1 1.3 16.3 5851×35 1.2 1.1 1.3 17.2 6901×50 1.4 1.1 1.4 19.0 8901×70 1.4 1.1 1.4 20.6 11101×95 1.6 1.1 1.5 23.1 14401×120 1.6 1.2 1.6 25.0 17351×150 1.8 1.2 1.7 27.0 20601×185 2.0 1.2 1.7 29.4 25451×240 2.2 1.2 1.8 32.6 31701×300 2.4 1.2 1.9 35.3 39101×400 2.4 1.4 2.1 41.0 51001×630 2.8 1.4 2.3 48.5 76602×1.5 1.0 1.1 1.2 14.2 3102×2.5 1.0 1.1 1.3 15.1 3602×4 1.0 1.1 1.3 16.6 4702×6 1.0 1.1 1.4 17.9 5552×10 1.0 1.1 1.4 19.9 7052×16 1.0 1.1 1.5 22.5 9852×25 1.2 1.2 1.6 26.4 13602×35 1.2 1.2 1.7 28.4 16202×50 1.4 1.2 1.9 32.4 22902×70 1.4 1.2 2.1 38.0 32602×95 1.6 1.2 2.3 41.6 39102×120 1.6 1.4 2.4 45.3 47102×150 1.8 1.4 2.6 49.7 56702×185 2.0 1.4 2.7 54.3 68402×240 2.2 1.6 3.0 61.5 87902×300 2.4 1.6 3.2 67.8 106303×1.5 1.0 1.1 1.3 14.8 3453×2.5 1.0 1.1 1.3 16.2 4453×4 1.0 1.1 1.3 17.4 5303×6 1.0 1.1 1.4 18.7 6353×10 1.0 1.1 1.5 21.1 8303×16 1.0 1.1 1.5 23.7 11603×25 1.2 1.2 1.7 28.1 16403×35 1.2 1.2 1.8 30.2 19803×50 1.4 1.2 2.0 34.3 27503×70 1.4 1.2 2.2 39.0 36753×95 1.6 1.4 2.4 44.7 4955
Fire Resistant Power and Control Cables
17ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
3×120 1.6 1.4 2.5 48.3 60353×150 1.8 1.4 2.7 53.2 73553×185 2.0 1.6 2.9 59.5 90253×240 2.2 1.6 3.2 66.5 115903×300 2.4 1.8 3.4 72.6 137404×1.5 1.0 1.1 1.3 16.4 4004×2.5 1.0 1.1 1.3 17.3 5054×4 1.0 1.1 1.4 18.8 6204×6 1.0 1.1 1.4 20.1 7504×10 1.0 1.1 1.5 22.7 9854×16 1.0 1.2 1.6 25.9 14004×25 1.2 1.2 1.8 30.7 19954×35 1.2 1.2 1.9 33.1 24404×50 1.4 1.4 2.0 38.2 34304×70 1.4 1.4 2.2 42.7 46004×95 1.6 1.6 2.4 49.4 61354×120 1.6 1.6 2.5 53.6 75154×150 1.8 1.6 2.9 59.0 90104×185 2.0 1.6 3.1 64.7 110004×240 2.2 1.8 3.4 73.1 141604×300 2.4 1.8 3.7 80.7 175505×1.5 1.0 1.1 1.4 17.7 5106×1.5 1.0 1.1 1.4 19.0 5457×1.5 1.0 1.1 1.4 19.0 5908×1.5 1.0 1.1 1.5 21.8 7159×1.5 1.0 1.1 1.6 23.3 72010×1.5 1.0 1.1 1.6 23.6 79012×1.5 1.0 1.2 1.6 24.3 88014×1.5 1.0 1.2 1.7 25.5 96516×1.5 1.0 1.2 1.7 26.7 103519×1.5 1.0 1.2 1.7 27.4 118520×1.5 1.0 1.2 1.8 29.5 126023×1.5 1.0 1.2 1.9 31.8 143524×1.5 1.0 1.2 2.0 33.2 151027×1.5 1.0 1.2 2.0 33.9 161530×1.5 1.0 1.2 2.0 34.9 173532×1.5 1.0 1.4 2.0 35.5 180033×1.5 1.0 1.4 2.0 36.7 194037×1.5 1.0 1.4 2.0 38.0 209044×1.5 1.0 1.4 2.3 42.6 2460
Fire Resistant Power and Control Cables
18 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
5×2.5 1.0 1.1 1.4 18.8 5956×2.5 1.0 1.1 1.4 20.4 6507×2.5 1.0 1.1 1.4 20.4 7008×2.5 1.0 1.1 1.5 23.5 7909×2.5 1.0 1.1 1.6 25.1 86010×2.5 1.0 1.1 1.6 25.4 95512×2.5 1.0 1.2 1.6 26.1 104514×2.5 1.0 1.2 1.7 27.3 116016×2.5 1.0 1.2 1.8 28.8 126519×2.5 1.0 1.2 1.8 29.6 144520×2.5 1.0 1.2 1.9 31.8 154523×2.5 1.0 1.4 2.0 34.7 180524×2.5 1.0 1.4 2.0 35.8 185027×2.5 1.0 1.4 2.0 35.4 197030×2.5 1.0 1.4 2.1 38.1 223533×2.5 1.0 1.4 2.2 39.6 239037×2.5 1.0 1.4 2.3 41.2 261044×2.5 1.0 1.4 2.4 46.2 3075
Fire Resistant Power and Control Cables
19ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P17 BU 0.6/1 kV
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for control, power and lighting systems.
Standards
IEC 60092-353
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-2
NEK 606:2004
Construction
Conductors: Tinned annealed stranded copper to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured black.
Electrical Characteristics
Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110
Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Mica Tape + HFEPR Insulation
Stranded Copper Conductor
SHF2 Sheath
Fire Resistant Power and Control Cables
20 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Nominal Cross Section Area mm² 50 70 95 120 150 185 240 300Nominal Conductor Diameter mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 196 242 293 339 389 444 522 601Continuous Current Rating@45℃ 2 Core A 167 206 249 288 331 444 444 511Continuous Current Rating@45℃ 3&4 Core A 137 169 205 237 272 311 365 421Short Circuit Current 1s A 7150 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1
3= ), I1= Current rating for 1-core, N = Number of cores.
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×1.5 1.0 1.0 6.4 651×2.5 1.0 1.0 6.8 751×4 1.0 1.0 7.4 951×6 1.0 1.0 7.9 1201×10 1.0 1.1 8.8 1701×16 1.0 1.1 10.2 2401×25 1.2 1.2 12.0 3601×35 1.2 1.2 13.1 4551×50 1.4 1.3 14.7 6001×70 1.4 1.4 16.6 8051×95 1.6 1.5 19.0 10951×120 1.6 1.5 20.6 13451×150 1.8 1.6 22.7 16351×185 2.0 1.7 25.2 2070
Fire Resistant Power and Control Cables
21ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×240 2.2 1.8 28.4 26551×300 2.4 1.9 31.1 33352×1.5 1.0 1.1 10.3 1552×2.5 1.0 1.2 11.0 1902×4 1.0 1.2 12.3 2502×6 1.0 1.3 13.4 3102×10 1.0 1.3 15.6 4452×16 1.0 1.4 18.2 6352×25 1.2 1.6 22.0 9702×35 1.2 1.7 24.0 12152×50 1.4 1.8 27.4 16152×70 1.4 1.9 32.6 23352×95 1.6 2.1 37.6 31552×120 1.6 2.3 41.2 38752×150 1.8 2.4 45.4 47252×185 2.0 2.6 50.2 58452×240 2.2 2.8 56.8 75702×300 2.4 3.1 63.0 93953×1.5 1.0 1.2 10.9 1803×2.5 1.0 1.2 11.9 2303×4 1.0 1.2 13.1 2953×6 1.0 1.3 14.2 3753×10 1.0 1.4 16.5 5503×16 1.0 1.5 19.3 7953×25 1.2 1.6 23.5 12203×35 1.2 1.7 25.6 15453×50 1.4 1.9 29.5 20753×70 1.4 2.0 33.2 27753×95 1.6 2.2 38.5 38003×120 1.6 2.4 42.0 46853×150 1.8 2.5 46.3 56853×185 2.0 2.7 51.8 72153×240 2.2 3.0 58.0 93203×300 2.4 3.2 67.6 122804×1.5 1.0 1.2 12.1 2254×2.5 1.0 1.2 13.0 2754×4 1.0 1.3 14.5 3654×6 1.0 1.4 15.8 4904×10 1.0 1.4 18.4 6954×16 1.0 1.5 21.5 10054×25 1.2 1.7 26.1 15504×35 1.2 1.8 28.5 19704×50 1.4 2.0 32.8 26454×70 1.4 2.2 36.9 3545
Fire Resistant Power and Control Cables
22 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
4×95 1.6 2.4 42.8 48504×120 1.6 2.6 46.5 59654×150 1.8 2.8 54.6 80204×185 2.0 3.0 60.3 99304×240 2.2 3.3 68.4 129204×300 2.4 3.5 75.5 159955×1.5 1.0 1.3 14.3 2656×1.5 1.0 1.3 15.6 3057×1.5 1.0 1.3 15.6 3208×1.5 1.0 1.4 18.4 4259×1.5 1.0 1.5 19.9 44010×1.5 1.0 1.5 20.2 49512×1.5 1.0 1.5 20.9 53014×1.5 1.0 1.6 21.9 63016×1.5 1.0 1.6 23.3 69019×1.5 1.0 1.6 24.6 79020×1.5 1.0 1.7 26.1 88023×1.5 1.0 1.8 28.4 103024×1.5 1.0 1.8 29.2 103527×1.5 1.0 1.8 29.9 108030×1.5 1.0 1.9 31.1 125033×1.5 1.0 1.9 32.3 133537×1.5 1.0 2.0 33.8 144544×1.5 1.0 2.2 38.4 17655×2.5 1.0 1.3 14.5 3406×2.5 1.0 1.4 17.0 3957×2.5 1.0 1.4 17.0 4208×2.5 1.0 1.5 20.0 5359×2.5 1.0 1.5 21.5 56010×2.5 1.0 1.5 21.8 62012×2.5 1.0 1.6 22.7 68014×2.5 1.0 1.6 23.9 81016×2.5 1.0 1.7 25.4 89519×2.5 1.0 1.7 26.8 100020×2.5 1.0 1.8 28.4 114023×2.5 1.0 1.9 30.9 132524×2.5 1.0 1.9 31.8 134027×2.5 1.0 1.9 32.5 139530×2.5 1.0 2.0 33.9 162033×2.5 1.0 2.0 35.2 173537×2.5 1.0 2.1 36.8 186544×2.5 1.0 2.3 41.8 2295
Fire Resistant Power and Control Cables
23ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P34 BFOU-HCF 0.6/1 kV
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control, power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.
Standards
IEC 60092-353
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Tinned annealed stranded compacted copper to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR/XLPE.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2. HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.Outer Sheath2: Flame retardant halogen-free thermoplastic compound, SHF1, coloured black.
SHF2 Sheath
Mica Tape + HFEPR/XLPE InsulationHalogen-free Bedding
Stranded Copper Conductor
SHF1 Sheath
HC-fire Protection + TapingCopper Wire Braid
Fire Resistant Power and Control Cables
24 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 1.5 2.5 4 6 16 35Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 5.1 7.4Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.16 0.529Continuous Current Rating@45℃ 1 Core A 23 30 40 52 96 157Continuous Current Rating@45℃ 2 Core A 20 26 34 44 82 133Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 67 110Short Circuit Current 1s A 210 360 570 860 2290 5010Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Nominal Cross Section Area mm² 50 70 95 120 150 185 240 300Nominal Conductor Diameter mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 196 242 293 339 389 444 522 601Continuous Current Rating@45℃ 2 Core A 167 206 249 288 331 444 444 511Continuous Current Rating@45℃ 3&4 Core A 137 169 205 237 272 311 365 421Short Circuit Current 1s A 7150 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1
3= ), I1= Current rating for 1-core, N = Number of cores.
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 12×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Fire Resistant Power and Control Cables
25ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Sheath1
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×50 1.4 15.0 18.5 45.5 29001×70 1.4 16.5 20.5 47.5 33001×95 1.6 18.5 23.0 50.5 38001×120 1.6 20.5 25.0 52.5 42601×150 1.8 23.0 27.0 54.5 47501×185 2.0 25.0 29.5 57.5 53801×240 2.2 28.0 32.5 66.0 70501×300 2.4 30.5 35.5 68.0 80002×1.5 1.0 10.0 13.0 40.5 18902×2.5 1.0 11.0 14.5 42.0 20803×1.5 1.0 10.5 14.0 42.0 21403×2.5 1.0 11.5 15.0 42.5 22003×4 1.0 13.0 16.5 43.0 24003×6 1.0 14.0 18.0 45.0 2600
3×16 1.0 18.5 23.0 50.0 35003×35 1.2 25.0 29.5 57.5 48403×70 1.4 33.0 39.0 72.0 81503×120 1.6 41.0 48.0 81.5 113003×150 1.8 46.0 54.5 88.5 133004×2.5 1.0 12.5 16.5 44.0 23004×6 1.0 15.5 19.5 47.5 2870
4×16 1.0 20.5 25.0 53.5 38307×1.5 1.0 14.0 17.5 44.5 2550
12×1.5 1.0 18.5 22.5 50.0 314027×1.5 1.0 26.5 31.0 64.5 50707×2.5 1.0 15.0 19.0 46.0 2760
12×2.5 1.0 20.5 24.5 52.0 3500
Medium Voltage Power Cables
26 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P2 or P2/P9 RFOU/TFOU 3.6/6KV
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P2), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P2/P9), coloured red.
Electrical Characteristics
Nominal Cross Section Area mm² 16 25 35 50 70 95 120Nominal Conductor Diameter mm 5.1 6.5 7.4 8.7 10.3 12.2 13.8
Copper Wire Braid
HFEPR/XLPE Insulation
Halogen-free BeddingStranded Copper Conductor
SHF2/SHF MUD SheathInsulation ScreenConductor Screen
Medium Voltage Power Cables
27ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154Continuous Current Rating@45℃ 1 Core A 96 127 157 196 242 293 339Continuous Current Rating@45℃ 3 Core A 67 89 110 137 169 205 237Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590 17170Operating Voltage KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6
Nominal Cross Section Area mm² 150 185 240 300 400 500 630Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.6 27.6 32.5Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 389 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 272 311 365 421 483 546 623Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 15×OD (during installation); 9×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×16 2.5 1.4 1.1 22.8 7801×25 2.5 1.5 1.1 24.0 10201×35 2.5 1.5 1.2 25.1 11551×50 2.5 1.6 1.2 26.3 13201×70 2.5 1.6 1.3 28.2 15951×95 2.5 1.7 1.3 30.0 19051×120 2.5 1.8 1.4 31.8 2235
Medium Voltage Power Cables
28 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×150 2.5 1.8 1.4 33.5 25501×185 2.5 1.9 1.5 35.4 30151×240 2.6 2.0 1.5 38.8 37251×300 2.8 2.1 1.6 42.3 46251×400 3.0 2.2 1.7 46.6 54201×500 3.2 2.4 1.8 50.8 66101×630 3.2 2.5 1.9 55.1 81703×16 2.5 2.2 1.6 44.9 29303×25 2.5 2.3 1.7 45.4 33903×35 2.5 2.4 1.8 47.6 38203×50 2.5 2.5 1.9 50.9 44953×70 2.5 2.7 2.0 54.8 55853×95 2.5 2.8 2.1 58.9 67653×120 2.5 3.0 2.2 63.5 81653×150 2.5 3.1 2.3 67.4 94953×185 2.5 3.3 2.4 75.8 106603×240 2.6 3.5 2.5 82.3 116603×300 2.8 3.8 2.7 89.3 12940
Medium Voltage Power Cables
29ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P3 or P3/P10 RFOU/TFOU 6/10KV
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10), coloured red.
Electrical Characteristics
Nominal Cross Section Area mm² 16 25 35 50 70 95 120Nominal Conductor Diameter mm 5.2 6.5 7.4 8.7 10.3 12.2 13.8
Copper Wire Braid
HFEPR/XLPE Insulation
Halogen-free BeddingStranded Copper Conductor
SHF2/SHF MUD SheathInsulation ScreenConductor Screen
Medium Voltage Power Cables
30 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154Continuous Current Rating@45℃ 1 Core A 96 127 157 196 242 293 339Continuous Current Rating@45℃ 3 Core A 67 89 110 137 169 205 237Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590 17170Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
Nominal Cross Section Area mm² 150 185 240 300 400 500 630Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 389 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 272 311 365 421 483 546 623Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 15×OD (during installation); 9×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×16 3.4 1.5 1.1 24.0 9001×25 3.4 1.5 1.2 26.0 11401×35 3.4 1.6 1.2 26.9 12651×50 3.4 1.6 1.2 28.3 14601×70 3.4 1.7 1.3 30.0 17101×95 3.4 1.8 1.3 32.0 20601×120 3.4 1.8 1.4 33.8 23801×150 3.4 1.9 1.4 35.3 2700
Medium Voltage Power Cables
31ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×185 3.4 2.0 1.5 37.8 32251×240 3.4 2.1 1.6 41.0 39901×300 3.4 2.2 1.6 43.7 47601×400 3.4 2.3 1.7 45.5 59001×500 3.4 2.4 1.8 49.5 73501×630 3.4 2.6 1.9 54.5 87503×16 3.4 2.3 1.7 46.0 33003×25 3.4 2.4 1.8 50.1 39053×35 3.4 2.5 1.8 52.2 43603×50 3.4 2.6 1.9 55.1 51853×70 3.4 2.7 2.0 58.9 61253×95 3.4 2.9 2.1 63.5 7500
3×120 3.4 3.0 2.2 67.6 87753×150 3.4 3.2 2.3 71.7 102353×185 3.4 3.4 2.4 74.0 113003×240 3.4 3.6 2.6 79.5 133003×300 3.4 3.8 2.7 85.0 16300
Medium Voltage Power Cables
32 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P4 or P4/P11 RFOU/TFOU 8.7/15KV
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P4), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P4/P11), coloured red.
Electrical Characteristics
Nominal Cross Section Area mm² 25 35 50 70 95 120Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8
Copper Wire Braid
HFEPR/XLPE Insulation
Halogen-free BeddingStranded Copper Conductor
SHF2/SHF MUD SheathInsulation ScreenConductor Screen
Medium Voltage Power Cables
33ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154Continuous Current Rating@45℃ 1 Core A 127 157 196 242 293 339Continuous Current Rating@45℃ 3 Core A 89 110 137 169 205 237Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170Operating Voltage KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15
Nominal Cross Section Area mm² 150 185 240 300 400 500 630Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 389 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 272 311 365 421 483 546 623Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 15×OD (during installation); 9×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer1×25 4.5 1.6 1.2 28.4 13051×35 4.5 1.6 1.3 29.3 14301×50 4.5 1.7 1.3 30.7 16201×70 4.5 1.8 1.3 32.4 19001×95 4.5 1.8 1.4 34.4 22501×120 4.5 1.9 1.5 36.6 26251×150 4.5 2.0 1.5 38.1 29401×185 4.5 2.0 1.5 40.6 3545
Medium Voltage Power Cables
34 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer1×240 4.5 2.1 1.6 43.4 42201×300 4.5 2.2 1.7 46.3 50701×400 4.5 2.4 1.8 50.2 57601×500 4.5 2.5 1.8 53.6 68801×630 4.5 2.6 1.9 57.9 84603×25 4.5 2.6 1.9 55.3 47253×35 4.5 2.7 2.0 57.5 52153×50 4.5 2.8 2.0 60.6 59603×70 4.5 2.9 2.1 64.4 70353×95 4.5 3.1 2.2 68.7 83703×120 4.5 3.2 2.3 72.7 97453×150 4.5 3.4 2.4 76.8 111403×185 4.5 3.6 2.6 84.2 134903×240 4.5 3.8 2.7 90.6 158603×300 4.5 4.0 2.9 96.6 18320
Medium Voltage Power Cables
35ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P19 or P19/P21 RFOU 12/20KV
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P19), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P19/P21), coloured red.
Optional
P20 or P20/P22 RFOU/TFOU 18/30(36) kV
Copper Wire Braid
HFEPR/XLPE Insulation
Halogen-free BeddingStranded Copper Conductor
SHF2/SHF MUD SheathInsulation ScreenConductor Screen
Medium Voltage Power Cables
36 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 16 25 35 50 70 95Nominal Conductor Diameter mm 5.2 6.5 7.4 8.7 10.3 12.2Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195Continuous Current Rating@45℃ 1 Core A 96 127 157 196 242 293Continuous Current Rating@45℃ 3 Core A 67 89 110 137 169 205Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590Operating Voltage KV 12/20 12/20 12/20 12/20 12/20 12/20
Nominal Cross Section Area mm² 120 150 185 240 300Nominal Conductor Diameter mm 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 339 389 444 522 601Continuous Current Rating@45℃ 3 Core A 237 272 311 365 421Short Circuit Current 1s A 17170 21460 26470 34340 42930Operating Voltage KV 12/20 12/20 12/20 12/20 12/20
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 15×OD (during installation); 9×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer1×16 5.5 1.4 1.2 28 12001×25 5.5 1.5 1.2 31.6 15301×35 5.5 1.8 1.3 32.3 1595
Medium Voltage Power Cables
37ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer1×50 5.5 1.8 1.4 33.8 17951×70 5.5 1.9 1.4 34.6 20701×95 5.5 2.0 1.5 37.0 24701×120 5.5 2.0 1.5 38.8 28101×150 5.5 2.1 1.6 40.7 32451×185 5.5 2.2 1.6 42.9 37651×240 5.5 2.3 1.7 45.8 45101×300 5.5 2.4 1.8 48.5 53153×16 5.5 1.8 2.0 55.5 49503×25 5.5 1.9 2.0 62.2 57053×35 5.5 2.9 2.1 62.6 59903×50 5.5 3.0 2.2 65.4 67403×70 5.5 3.1 2.3 69.1 77903×95 5.5 3.3 2.4 73.0 91503×120 5.5 3.4 2.5 77.4 105803×150 5.5 3.6 2.6 81.9 121453×185 5.5 3.8 2.7 89.5 122653×240 5.5 4.0 2.9 96.1 147253×300 5.5 4.2 3.0 101.9 17190
Fire Resistant Medium Voltage Power Cables
38 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P6 or P6/P13 BFOU 3.6/6kV
Applications
These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Mica tape + Halogen free EPR. Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P6), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P6/P13), coloured red.
Copper Wire Braid
Mica Tape + HFEPR Insulation
Halogen-free BeddingStranded Copper Conductor
SHF MUD SheathInsulation ScreenConductor Screen
Fire Resistant Medium Voltage Power Cables
39ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 25 35 50 70 95 120 150Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8 15.1Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 0.126Continuous Current Rating@45℃ 1 Core A 127 157 196 242 293 339 389Continuous Current Rating@45℃ 3 Core A 89 110 137 169 205 237 272Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170 21460Operating Voltage KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6
Nominal Cross Section Area mm² 185 240 300 400 500 630Nominal Conductor Diameter mm 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 311 365 421 483 546 623Short Circuit Current 1s A 26470 34340 42930 57230 71540 90140Operating Voltage KV 3.6/6 3.6/6 3.6/6 8.7/15 8.7/15 8.7/15
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 15×OD (during installation); 9×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×16 2.5 1.5 1.2 24.8 9501×25 2.5 1.6 1.2 26.3 1110
Fire Resistant Medium Voltage Power Cables
40 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×35 2.5 1.6 1.2 27.6 12601×50 2.5 1.7 1.3 29.1 14601×70 2.5 1.7 1.3 30.9 17401×95 2.5 1.8 1.4 33.2 21101×120 2.5 1.9 1.4 34.9 24301×150 2.5 1.9 1.4 36.9 28901×185 2.5 2.0 1.5 39.1 33701×240 2.6 2.1 1.6 42.2 41001×300 2.8 2.2 1.6 44.7 48101×400 3.0 2.3 1.7 48.1 58101×500 3.2 2.5 1.8 52.1 70301×630 3.2 2.6 1.9 56.5 86303×16 2.5 2.3 1.7 48.2 35503×25 2.5 2.5 1.8 51.5 41803×35 2.5 2.6 1.9 54.7 48203×50 2.5 2.7 1.9 57.4 54903×70 2.5 2.8 2.0 61.6 65903×95 2.5 3.0 2.1 66.2 79203×120 2.5 3.1 2.2 70.1 91503×150 2.5 3.3 2.3 74.0 104603×185 2.5 3.4 2.4 78.6 120103×240 2.6 3.7 2.6 86.3 146903×300 2.8 3.9 2.8 92.3 17130
Fire Resistant Medium Voltage Power Cables
41ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P7 or P7/P14 BFOU 6/10kV
Applications
These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Mica tape + Halogen free EPR. Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P7), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P7/P14), coloured red.
Copper Wire Braid
Mica Tape + HFEPR Insulation
Halogen-free BeddingStranded Copper Conductor
SHF MUD SheathInsulation ScreenConductor Screen
Fire Resistant Medium Voltage Power Cables
42 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 25 35 50 70 95 120 150Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8 15.1Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 0.126Continuous Current Rating@45℃ 1 Core A 127 157 196 242 293 339 389Continuous Current Rating@45℃ 3 Core A 89 110 137 169 205 237 272Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170 21460Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
Nominal Cross Section Area mm² 185 240 300 400 500 630Nominal Conductor Diameter mm 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 311 365 421 483 546 623Short Circuit Current 1s A 26470 34340 42930 57230 71540 90140Operating Voltage KV 6/10 6/10 6/10 8.7/15 8.7/15 8.7/15
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 15×OD (during installation); 9×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×16 3.4 1.5 1.2 25.6 9901×25 3.4 1.6 1.2 27.1 1150
Fire Resistant Medium Voltage Power Cables
43ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×35 3.4 1.7 1.2 28.5 13201×50 3.4 1.7 1.3 29.9 15001×70 3.4 1.8 1.3 31.9 18101×95 3.4 1.8 1.4 34.0 21601×120 3.4 1.9 1.4 36.1 26101×150 3.4 2.0 1.5 38.1 29901×185 3.4 2.0 1.5 39.9 34401×240 3.4 2.2 1.6 43.1 41801×300 3.4 2.3 1.7 45.9 49301×400 3.4 2.4 1.7 49.0 59001×500 3.4 2.5 1.8 52.5 70701×630 3.4 2.7 1.9 57.0 86903×16 3.4 2.4 1.8 50.2 37803×25 3.4 2.5 1.8 53.2 43803×35 3.4 2.6 1.9 56.4 50403×50 3.4 2.7 2.0 59.3 57403×70 3.4 2.9 2.1 63.7 69003×95 3.4 3.1 2.2 68.4 82703×120 3.4 3.2 2.3 72.1 94703×150 3.4 3.3 2.4 76.0 108003×185 3.4 3.5 2.5 80.8 123703×240 3.4 3.7 2.7 88.2 150403×300 3.4 3.9 2.9 94.0 17450
Fire Resistant Medium Voltage Power Cables
44 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P30 RFOU-HCF / TFOU-HCF 6/10(12) kV
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control, power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.
Standards
IEC 60092-354
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option.Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2, coloured red.HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.Outer Sheath2: Flame retardant halogen-free thermoplastic compound, SHF1, coloured red.
Copper Wire Braid
HFEPR/XLPE Insulation
Halogen-free BeddingStranded Copper Conductor
SHF2 SheathInsulation ScreenConductor Screen
SHF1 Sheath
HC-fire Protection + Taping
Fire Resistant Medium Voltage Power Cables
45ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Optional
P31 RFOU-HCF / TFOU-HCF 8.7/15kVP32 RFOU-HCF / TFOU-HCF 12/20(24) kVP33 RFOU-HCF / TFOU-HCF 18/30(36) kV
Electrical Characteristics
Nominal Cross Section Area mm² 70 95 120 150 185 240 300Nominal Conductor Diameter mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 242 293 339 389 444 522 601Continuous Current Rating@45℃ 3 Core A 169 205 237 272 311 365 421Short Circuit Current 1s A 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10
Ambient Temperature Correction Factors
Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 12×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Sheath1
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×70 3.4 23.5 30.0 62.0 52201×95 3.4 25.5 32.0 64.5 59001×120 3.4 27.5 34.0 66.5 63401×150 3.4 28.5 35.0 67.5 6670
Fire Resistant Medium Voltage Power Cables
46 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of cores×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Sheath1
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×185 3.4 30.5 36.5 69.0 73201×240 3.4 33.0 39.0 72.0 82501×300 3.4 35.0 41.5 74.5 92803×50 3.4 47.0 55.0 89.0 109703×95 3.4 54.0 62.5 97.0 14230
3×150 3.4 60.0 70.5 106.0 17400
Instrumentation Cables
47ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S1 or S1/S5 RFOU(i) 250V
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S1). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S1/S5), coloured grey (blue for intrinsically safe).
Copper Wire Braid
HFEPR Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF2/SHF MUD Sheath
Copper/Polyester Tape + Drain Wire
Instrumentation Cables
48 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 90 100 110 120Nominal Inductance@1KHz MH/km 0.686 0.649 0.637 0.598Maximum L/R@1KHz μH/Ω 20 25 35 50Operating Voltage V 250 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×2×0.75 0.6 1.1 1.1 10.9 2102×2×0.75 0.6 1.1 1.3 13.2 3254×2×0.75 0.6 1.1 1.3 16.2 4807×2×0.75 0.6 1.1 1.4 19.0 6708×2×0.75 0.6 1.1 1.4 20.4 7559×2×0.75 0.6 1.1 1.5 22.6 835
10×2×0.75 0.6 1.1 1.5 23.5 87512×2×0.75 0.6 1.1 1.5 24.1 101014×2×0.75 0.6 1.1 1.6 25.3 104015×2×0.75 0.6 1.1 1.6 26.9 112016×2×0.75 0.6 1.1 1.6 27.3 116518×2×0.75 0.6 1.1 1.7 28.7 127019×2×0.75 0.6 1.1 1.7 29.0 136020×2×0.75 0.6 1.1 1.7 30.1 142021×2×0.75 0.6 1.1 1.8 31.0 149023×2×0.75 0.6 1.1 1.8 31.5 159524×2×0.75 0.6 1.2 1.8 33.4 172027×2×0.75 0.6 1.2 1.9 34.0 177030×2×0.75 0.6 1.2 1.9 35.1 1910
Instrumentation Cables
49ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
32×2×0.75 0.6 1.2 2.0 36.1 206033×2×0.75 0.6 1.2 2.0 36.9 216037×2×0.75 0.6 1.2 2.0 38.0 23301×3×0.75 0.6 1.1 1.2 11.3 2252×3×0.75 0.6 1.1 1.3 16.4 4903×3×0.75 0.6 1.1 1.4 17.2 5204×3×0.75 0.6 1.1 1.4 18.5 6105×3×0.75 0.6 1.1 1.5 19.8 7206×3×0.75 0.6 1.1 1.5 21.7 8357×3×0.75 0.6 1.1 1.5 21.7 8708×3×0.75 0.6 1.1 1.6 23.5 9509×3×0.75 0.6 1.1 1.6 24.6 106510×3×0.75 0.6 1.1 1.7 26.4 109512×3×0.75 0.6 1.1 1.7 27.3 127514×3×0.75 0.6 1.1 1.8 28.5 132015×3×0.75 0.6 1.1 1.8 29.3 139516×3×0.75 0.6 1.1 1.8 30.1 146518×3×0.75 0.6 1.1 1.9 31.6 160019×3×0.75 0.6 1.1 1.9 31.9 165520×3×0.75 0.6 1.2 2.0 33.2 182021×3×0.75 0.6 1.2 2.0 33.8 189023×3×0.75 0.6 1.2 2.0 35.1 205024×3×0.75 0.6 1.2 2.0 36.0 222027×3×0.75 0.6 1.2 2.1 37.9 233530×3×0.75 0.6 1.2 2.2 39.7 255532×3×0.75 0.6 1.2 2.2 40.7 26901×2×1.0 0.6 1.1 1.2 11.4 2302×2×1.0 0.6 1.1 1.3 14.5 3703×2×1.0 0.6 1.1 1.3 16.6 5154×2×1.0 0.6 1.1 1.4 17.4 5955×2×1.0 0.6 1.1 1.4 19.1 6856×2×1.0 0.6 1.1 1.5 20.7 7907×2×1.0 0.6 1.1 1.5 20.7 8208×2×1.0 0.6 1.1 1.6 21.6 8759×2×1.0 0.6 1.1 1.6 23.8 99510×2×1.0 0.6 1.1 1.6 24.8 101012×2×1.0 0.6 1.1 1.7 25.6 119514×2×1.0 0.6 1.1 1.7 26.7 121015×2×1.0 0.6 1.1 1.8 28.5 132016×2×1.0 0.6 1.1 1.8 29.0 137518×2×1.0 0.6 1.1 1.9 30.5 150019×2×1.0 0.6 1.1 1.9 30.8 1555
Instrumentation Cables
50 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
20×2×1.0 0.6 1.1 1.9 31.9 168021×2×1.0 0.6 1.2 2.0 33.3 179023×2×1.0 0.6 1.2 2.0 33.7 192024×2×1.0 0.6 1.2 2.0 35.2 201527×2×1.0 0.6 1.2 2.1 36.5 218530×2×1.0 0.6 1.2 2.1 37.7 236533×2×1.0 0.6 1.2 2.2 39.2 257037×2×1.0 0.6 1.2 2.2 40.4 27751×3×1.0 0.6 1.1 1.2 11.8 2502×3×1.0 0.6 1.1 1.4 17.3 5553×3×1.0 0.6 1.1 1.4 17.9 5904×3×1.0 0.6 1.1 1.4 19.4 7005×3×1.0 0.6 1.1 1.5 20.7 8256×3×1.0 0.6 1.1 1.6 23.0 9757×3×1.0 0.6 1.1 1.6 23.0 9908×3×1.0 0.6 1.1 1.6 24.4 10959×3×1.0 0.6 1.1 1.7 26.4 1245
10×3×1.0 0.6 1.1 1.8 28.0 126512×3×1.0 0.6 1.1 1.8 28.9 150014×3×1.0 0.6 1.1 1.8 30.0 154515×3×1.0 0.6 1.1 1.9 31.1 165516×3×1.0 0.6 1.1 1.9 31.8 187018×3×1.0 0.6 1.2 2.0 33.9 193519×3×1.0 0.6 1.2 2.0 34.2 204020×3×1.0 0.6 1.2 2.0 35.1 215021×3×1.0 0.6 1.2 2.1 35.9 224523×3×1.0 0.6 1.2 2.1 37.6 252524×3×1.0 0.6 1.2 2.1 38.7 268527×3×1.0 0.6 1.2 2.2 40.3 278530×3×1.0 0.6 1.2 2.3 42.1 305032×3×1.0 0.6 1.2 2.3 43.2 32151×2×1.5 0.7 1.1 1.2 12.4 2702×2×1.5 0.7 1.1 1.4 15.8 4953×2×1.5 0.7 1.1 1.4 17.9 6404×2×1.5 0.7 1.1 1.5 19.5 7155×2×1.5 0.7 1.1 1.5 21.5 8506×2×1.5 0.7 1.1 1.6 23.3 9907×2×1.5 0.7 1.1 1.6 23.3 10308×2×1.5 0.7 1.1 1.7 24.8 11309×2×1.5 0.7 1.1 1.7 26.9 123010×2×1.5 0.7 1.1 1.8 28.2 127012×2×1.5 0.7 1.1 1.8 29.3 1375
Instrumentation Cables
51ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
14×2×1.5 0.7 1.1 1.8 30.2 152015×2×1.5 0.7 1.2 1.9 32.7 168516×2×1.5 0.7 1.2 2.0 33.4 177518×2×1.5 0.7 1.2 2.0 35.0 192019×2×1.5 0.7 1.2 2.0 35.3 199020×2×1.5 0.7 1.2 2.1 37.2 225521×2×1.5 0.7 1.2 2.1 38.2 234523×2×1.5 0.7 1.2 2.2 39.0 254024×2×1.5 0.7 1.2 2.2 40.7 261027×2×1.5 0.7 1.2 2.3 41.7 277530×2×1.5 0.7 1.2 2.3 43.1 300533×2×1.5 0.7 1.4 2.4 45.1 348037×2×1.5 0.7 1.4 2.5 46.7 36001×3×1.5 0.7 1.1 1.2 13.0 3002×3×1.5 0.7 1.1 1.4 17.5 5103×3×1.5 0.7 1.1 1.5 20.1 7404×3×1.5 0.7 1.1 1.5 21.8 8705×3×1.5 0.7 1.1 1.6 23.3 10456×3×1.5 0.7 1.1 1.7 25.9 12307×3×1.5 0.7 1.1 1.7 26.0 12658×3×1.5 0.7 1.1 1.8 27.8 14059×3×1.5 0.7 1.1 1.8 29.5 1585
10×3×1.5 0.7 1.1 1.9 31.8 168012×3×1.5 0.7 1.2 2.0 33.1 195014×3×1.5 0.7 1.2 2.0 34.6 202015×3×1.5 0.7 1.2 2.0 35.6 214516×3×1.5 0.7 1.2 2.1 36.6 245018×3×1.5 0.7 1.2 2.2 39.2 258019×3×1.5 0.7 1.2 2.2 39.5 267520×3×1.5 0.7 1.2 2.2 40.5 287521×3×1.5 0.7 1.2 2.3 41.5 300023×3×1.5 0.7 1.2 2.3 43.0 326024×3×1.5 0.7 1.4 2.4 44.9 331027×3×1.5 0.7 1.4 2.4 46.4 363530×3×1.5 0.7 1.4 2.5 48.5 398032×3×1.5 0.7 1.4 2.6 50.0 42251×2×2.5 0.7 1.1 1.2 13.3 3202×2×2.5 0.7 1.1 1.4 17.5 5303×2×2.5 0.7 1.1 1.5 20.2 7804×2×2.5 0.7 1.1 1.5 21.5 9005×2×2.5 0.7 1.1 1.6 23.4 10606×2×2.5 0.7 1.1 1.7 25.4 1235
Instrumentation Cables
52 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
7×2×2.5 0.7 1.1 1.7 25.4 12908×2×2.5 0.7 1.1 1.7 27.5 14009×2×2.5 0.7 1.1 1.8 29.4 1495
10×2×2.5 0.7 1.1 1.9 30.9 159512×2×2.5 0.7 1.1 1.9 31.6 175514×2×2.5 0.7 1.2 2.0 33.6 199015×2×2.5 0.7 1.2 2.1 36.0 216516×2×2.5 0.7 1.2 2.1 36.9 235018×2×2.5 0.7 1.2 2.2 38.9 256519×2×2.5 0.7 1.2 2.2 39.3 266520×2×2.5 0.7 1.2 2.2 40.8 288021×2×2.5 0.7 1.2 2.3 42.1 302023×2×2.5 0.7 1.2 2.3 42.7 325524×2×2.5 0.7 1.4 2.4 45.2 333027×2×2.5 0.7 1.4 2.4 46.1 361530×2×2.5 0.7 1.4 2.5 47.8 395033×2×2.5 0.7 1.4 2.6 49.7 430037×2×2.5 0.7 1.4 2.6 51.2 46701×3×2.5 0.7 1.1 1.3 13.9 3552×3×2.5 0.7 1.1 1.5 20.9 8403×3×2.5 0.7 1.1 1.5 21.6 9454×3×2.5 0.7 1.1 1.6 23.3 11155×3×2.5 0.7 1.1 1.7 25.4 13156×3×2.5 0.7 1.1 1.8 28.3 15557×3×2.5 0.7 1.1 1.8 28.3 16408×3×2.5 0.7 1.1 1.8 30.2 17809×3×2.5 0.7 1.2 1.9 32.6 2055
10×3×2.5 0.7 1.2 2.0 35.1 208012×3×2.5 0.7 1.2 2.1 36.8 243514×3×2.5 0.7 1.2 2.1 38.3 270015×3×2.5 0.7 1.2 2.2 39.7 289516×3×2.5 0.7 1.2 2.2 40.8 305018×3×2.5 0.7 1.2 2.3 42.9 333519×3×2.5 0.7 1.2 2.3 43.3 347020×3×2.5 0.7 1.4 2.4 44.9 378521×3×2.5 0.7 1.4 2.4 45.8 393523×3×2.5 0.7 1.4 2.5 47.7 415024×3×2.5 0.7 1.4 2.5 48.6 430027×3×2.5 0.7 1.4 2.6 51.1 476530×3×2.5 0.7 1.4 2.7 53.5 523532×3×2.5 0.7 1.6 2.8 55.5 5620
Instrumentation Cables
53ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S2 or S2/S6 RFOU(c) 250V
Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S2). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S2/S6), coloured grey (blue for intrinsically safe).
Copper Wire Braid
HFEPR Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF2/SHF MUD Sheath
Copper/Polyester Tape + Drain Wire
Instrumentation Cables
54 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 80 90 100 110Nominal Inductance@1KHz MH/km 0.682 0.645 0.632 0.593Maximum L/R@1KHz μH/Ω 20 25 35 50Operating Voltage V 250 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×2×0.75 0.6 1.1 1.1 11.1 2002×2×0.75 0.6 1.1 1.3 15.0 2953×2×0.75 0.6 1.1 1.3 15.6 3554×2×0.75 0.6 1.1 1.3 16.4 3905×2×0.75 0.6 1.1 1.4 17.8 5406×2×0.75 0.6 1.1 1.4 19.1 6107×2×0.75 0.6 1.1 1.4 19.1 6258×2×0.75 0.6 1.1 1.5 20.7 6809×2×0.75 0.6 1.1 1.5 21.8 745
10×2×0.75 0.6 1.1 1.6 22.9 76012×2×0.75 0.6 1.1 1.6 23.4 81014×2×0.75 0.6 1.1 1.6 24.5 87515×2×0.75 0.6 1.1 1.7 26.1 96016×2×0.75 0.6 1.1 1.7 26.5 101018×2×0.75 0.6 1.1 1.8 27.9 108019×2×0.75 0.6 1.1 1.8 28.2 111520×2×0.75 0.6 1.1 1.8 29.2 121021×2×0.75 0.6 1.1 1.8 30.0 125523×2×0.75 0.6 1.1 1.9 30.6 135524×2×0.75 0.6 1.1 1.9 31.9 1370
Instrumentation Cables
55ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
27×2×0.75 0.6 1.2 1.9 32.9 148030×2×0.75 0.6 1.2 2.0 34.1 160533×2×0.75 0.6 1.2 2.0 35.3 172537×2×0.75 0.6 1.2 2.1 36.9 19501×3×0.75 0.6 1.1 1.2 11.7 2302×3×0.75 0.6 1.1 1.3 14.5 3603×3×0.75 0.6 1.1 1.3 16.2 4154×3×0.75 0.6 1.1 1.4 17.6 5405×3×0.75 0.6 1.1 1.4 19.1 6456×3×0.75 0.6 1.1 1.5 21.1 7557×3×0.75 0.6 1.1 1.5 21.1 7808×3×0.75 0.6 1.1 1.6 22.6 8459×3×0.75 0.6 1.1 1.6 23.9 945
10×3×0.75 0.6 1.1 1.7 25.7 96012×3×0.75 0.6 1.1 1.7 26.4 108014×3×0.75 0.6 1.1 1.7 27.5 115015×3×0.75 0.6 1.1 1.8 28.5 123016×3×0.75 0.6 1.1 1.8 29.2 131018×3×0.75 0.6 1.1 1.9 30.7 140519×3×0.75 0.6 1.1 1.9 31.0 147520×3×0.75 0.6 1.1 1.9 31.8 156021×3×0.75 0.6 1.2 1.9 32.7 164023×3×0.75 0.6 1.2 2.0 34.1 179524×3×0.75 0.6 1.2 2.0 34.6 183027×3×0.75 0.6 1.2 2.1 36.8 204030×3×0.75 0.6 1.2 2.1 38.3. 221032×3×0.75 0.6 1.2 2.2 39.5 23451×2×1.0 0.6 1.1 1.2 11.7 2252×2×1.0 0.6 1.1 1.3 13.4 3353×2×1.0 0.6 1.1 1.3 16.3 4704×2×1.0 0.6 1.1 1.4 17.4 5355×2×1.0 0.6 1.1 1.4 18.7 6106×2×1.0 0.6 1.1 1.5 20.2 7007×2×1.0 0.6 1.1 1.5 20.2 7208×2×1.0 0.6 1.1 1.5 21.8 7759×2×1.0 0.6 1.1 1.6 23.2 850
10×2×1.0 0.6 1.1 1.6 24.1 88012×2×1.0 0.6 1.1 1.6 24.7 98014×2×1.0 0.6 1.1 1.7 26.0 103015×2×1.0 0.6 1.1 1.8 27.8 112516×2×1.0 0.6 1.1 1.8 28.2 117518×2×1.0 0.6 1.1 1.8 29.5 125519×2×1.0 0.6 1.1 1.8 29.8 1295
Instrumentation Cables
56 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
20×2×1.0 0.6 1.1 1.9 31.1 142021×2×1.0 0.6 1.1 1.9 31.9 147523×2×1.0 0.6 1.2 1.9 32.7 161024×2×1.0 0.6 1.2 2.0 34.3 162027×2×1.0 0.6 1.2 2.0 35.0 174530×2×1.0 0.6 1.2 2.1 36.7 198033×2×1.0 0.6 1.2 2.1 38.0 213037×2×1.0 0.6 1.2 2.2 39.3 23051×3×1.0 0.6 1.1 1.2 12.0 2502×3×1.0 0.6 1.1 1.4 17.0 5203×3×1.0 0.6 1.1 1.4 17.4 5404×3×1.0 0.6 1.1 1.4 18.7 6255×3×1.0 0.6 1.1 1.5 20.2 7456×3×1.0 0.6 1.1 1.6 22.4 8757×3×1.0 0.6 1.1 1.6 22.4 9058×3×1.0 0.6 1.1 1.6 23.8 9809×3×1.0 0.6 1.1 1.7 25.4 1080
10×3×1.0 0.6 1.1 1.7 27.1 115012×3×1.0 0.6 1.1 1.8 28.1 126514×3×1.0 0.6 1.1 1.8 29.2 135515×3×1.0 0.6 1.1 1.8 30.1 144016×3×1.0 0.6 1.1 1.9 31.1 157018×3×1.0 0.6 1.2 1.9 32.8 167519×3×1.0 0.6 1.2 2.0 33.3 175020×3×1.0 0.6 1.2 2.0 34.1 188021×3×1.0 0.6 1.2 2.0 34.8 195023×3×1.0 0.6 1.2 2.1 36.6 221524×3×1.0 0.6 1.2 2.1 37.3 220027×3×1.0 0.6 1.2 2.2 39.2 242530×3×1.0 0.6 1.2 2.2 40.8 263032×3×1.0 0.6 1.2 2.3 42.1 27901×2×1.5 0.7 1.1 1.2 12.7 2602×2×1.5 0.7 1.1 1.4 15.4 4203×2×1.5 0.7 1.1 1.4 17.6 5854×2×1.5 0.7 1.1 1.4 18.8 6355×2×1.5 0.7 1.1 1.5 21.1 7706×2×1.5 0.7 1.1 1.6 22.8 8907×2×1.5 0.7 1.1 1.6 22.8 9258×2×1.5 0.7 1.1 1.6 23.7 9759×2×1.5 0.7 1.1 1.7 26.3 1060
10×2×1.5 0.7 1.1 1.7 27.4 113012×2×1.5 0.7 1.1 1.8 28.3 127014×2×1.5 0.7 1.1 1.8 29.5 1325
Instrumentation Cables
57ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
15×2×1.5 0.7 1.1 1.9 31.6 144516×2×1.5 0.7 1.1 1.9 32.1 157518×2×1.5 0.7 1.2 2.0 34.2 167019×2×1.5 0.7 1.2 2.0 34.5 176520×2×1.5 0.7 1.2 2.1 36.0 189521×2×1.5 0.7 1.2 2.1 37.3 205023×2×1.5 0.7 1.2 2.1 37.9 218524×2×1.5 0.7 1.2 2.2 39.8 220027×2×1.5 0.7 1.2 2.2 40.6 239030×2×1.5 0.7 1.2 2.3 42.1 260033×2×1.5 0.7 1.2 2.3 43.6 280537×2×1.5 0.7 1.4 2.4 45.4 30801×3×1.5 0.7 1.1 1.2 13.2 2952×3×1.5 0.7 1.1 1.4 17.0 4903×3×1.5 0.7 1.1 1.5 19.5 6854×3×1.5 0.7 1.1 1.5 20.9 7855×3×1.5 0.7 1.1 1.6 21.0 8206×3×1.5 0.7 1.1 1.7 22.8 9607×3×1.5 0.7 1.1 1.7 25.1 11358×3×1.5 0.7 1.1 1.7 27.0 12709×3×1.5 0.7 1.1 1.8 28.9 1445
10×3×1.5 0.7 1.1 1.9 31.1 145012×3×1.5 0.7 1.1 1.9 31.5 171014×3×1.5 0.7 1.2 2.0 33.8 181515×3×1.5 0.7 1.2 2.0 34.8 193016×3×1.5 0.7 1.2 2.1 36.0 211018×3×1.5 0.7 1.2 2.1 38.1 230519×3×1.5 0.7 1.2 2.2 38.6 237520×3×1.5 0.7 1.2 2.2 39.6 258021×3×1.5 0.7 1.2 2.2 40.4 268023×3×1.5 0.7 1.2 2.3 42.0 292524×3×1.5 0.7 1.2 2.3 42.7 314027×3×1.5 0.7 1.4 2.4 45.3 325030×3×1.5 0.7 1.4 2.5 47.4 355532×3×1.5 0.7 1.4 2.5 48.6 37451×2×2.5 0.7 1.1 1.2 13.5 3002×2×2.5 0.7 1.1 1.4 18.9 6503×2×2.5 0.7 1.1 1.5 19.9 7204×2×2.5 0.7 1.1 1.5 21.1 8205×2×2.5 0.7 1.1 1.6 23.0 9656×2×2.5 0.7 1.1 1.6 24.8 11057×2×2.5 0.7 1.1 1.6 24.8 11508×2×2.5 0.7 1.1 1.7 27.0 1255
Instrumentation Cables
58 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
9×2×2.5 0.7 1.1 1.8 28.8 138510×2×2.5 0.7 1.1 1.8 30.0 143012×2×2.5 0.7 1.3 1.9 31.0 154514×2×2.5 0.7 1.2 1.9 32.7 173015×2×2.5 0.7 1.2 2.0 35.0 188516×2×2.5 0.7 1.2 2.0 35.6 197018×2×2.5 0.7 1.2 2.1 37.9 223519×2×2.5 0.7 1.2 2.1 38.3 231520×2×2.5 0.7 1.2 2.2 39.9 253021×2×2.5 0.7 1.2 2.2 41.0 263023×2×2.5 0.7 1.2 2.3 41.8 275024×2×2.5 0.7 1.2 2.3 43.7 285027×2×2.5 0.7 1.4 2.4 45.1 315030×2×2.5 0.7 1.4 2.5 46.8 343533×2×2.5 0.7 1.4 2.5 48.5 371537×2×2.5 0.7 1.4 2.6 50.2 40401×3×2.5 0.7 1.1 1.3 14.3 3602×3×2.5 0.7 1.1 1.5 20.5 7853×3×2.5 0.7 1.1 1.5 21.2 8754×3×2.5 0.7 1.1 1.6 22.9 10355×3×2.5 0.7 1.1 1.6 24.8 12056×3×2.5 0.7 1.1 1.8 27.8 14307×3×2.5 0.7 1.1 1.8 27.8 15058×3×2.5 0.7 1.1 1.8 29.6 16259×3×2.5 0.7 1.1 1.9 31.7 1855
10×3×2.5 0.7 1.2 2.0 34.4 189012×3×2.5 0.7 1.2 2.0 35.5 211014×3×2.5 0.7 1.2 2.1 37.6 244515×3×2.5 0.7 1.2 2.2 38.9 262016×3×2.5 0.7 1.2 2.2 40.0 275518×3×2.5 0.7 1.2 2.3 42.0 301019×3×2.5 0.7 1.2 2.3 42.4 312520×3×2.5 0.7 1.2 2.3 43.5 336021×3×2.5 0.7 1.4 2.4 44.9 355523×3×2.5 0.7 1.4 2.5 46.7 388524×3×2.5 0.7 1.4 2.5 47.5 387027×3×2.5 0.7 1.4 2.6 50.0 428030×3×2.5 0.7 1.4 2.7 52.3 469532×3×2.5 0.7 1.4 2.7 53.8 4960
Instrumentation Cables
59ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
P16 IFLI 250 V
Applications
These cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular stranded copper wire to IEC 60228 class 2. Insulation: XLPE.Bedding: Halogen free thermoplastic compound.Metal Screen: Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor.Outer Sheath: Halogen free thermoplastic compound, SHF1, coloured grey.
Electrical Characteristics
Nominal Cross Section Area mm² 2.5Maximum Resistant@20℃ Ω/km 7.41Continuous Current Rating@45℃ 2 Core A 26Short Circuit Current 1s A 360Operating Voltage V 250
XLPE Insulation
Stranded Copper Conductor
SHF1 Sheath
Halogen Free Thermoplastic Bedding
Aluminium Tape + Earth Conductor
Instrumentation Cables
60 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in element×Cross
section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
2×1×2.5 0.7 1.1 1.2 10.0 180
Instrumentation Cables
61ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S11 RU(i) 250 V
Applications
These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0
HFEPR Insulation
Stranded Copper Conductor
SHF2 Sheath
Copper/Polyester Tape + Drain Wire
Instrumentation Cables
62 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 90 100 110 120Nominal Inductance@1KHz MH/km 0.686 0.649 0.637 0.598Maximum L/R@1KHz μH/Ω 20 25 35 50Operating Voltage V 250 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×2×0.75 0.6 1.0 7.6 952×2×0.75 0.6 1.1 9.7 1804×2×0.75 0.6 1.2 12.1 2557×2×0.75 0.6 1.3 14.4 3808×2×0.75 0.6 1.3 15.6 425
12×2×0.75 0.6 1.5 19.0 61016×2×0.75 0.6 1.5 21.0 78519×2×0.75 0.6 1.6 22.4 89524×2×0.75 0.6 1.7 25.6 113532×2×0.75 0.6 1.8 28.4 14401×3×0.75 0.6 1.0 8.0 1102×3×0.75 0.6 1.2 11.0 1803×3×0.75 0.6 1.2 12.7 2654×3×0.75 0.6 1.2 13.8 3257×3×0.75 0.6 1.4 16.7 5008×3×0.75 0.6 1.4 18.0 540
12×3×0.75 0.6 1.6 22.2 81516×3×0.75 0.6 1.6 24.7 104519×3×0.75 0.6 1.7 26.2 120524×3×0.75 0.6 1.9 30.5 15451×2×1.0 0.6 1.0 8.1 1102×2×1.0 0.6 1.1 10.4 2154×2×1.0 0.6 1.2 12.9 3107×2×1.0 0.6 1.4 15.5 4758×2×1.0 0.6 1.4 17.0 540
Instrumentation Cables
63ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
12×2×1.0 0.6 1.5 20.5 76016×2×1.0 0.6 1.5 22.9 99519×2×1.0 0.6 1.7 24.1 113524×2×1.0 0.6 1.8 27.8 145032×2×1.0 0.6 1.9 30.8 18501×3×1.0 0.6 1.0 8.5 1253×3×1.0 0.6 1.3 13.4 3204×3×1.0 0.6 1.3 14.8 3957×3×1.0 0.6 1.5 17.9 615
12×3×1.0 0.6 1.6 23.7 99016×3×1.0 0.6 1.7 26.5 129519×3×1.0 0.6 1.8 28.0 147524×3×1.0 0.6 2.0 32.6 19001×2×1.5 0.7 1.0 9.1 1402×2×1.5 0.7 1.2 11.7 2804×2×1.5 0.7 1.3 14.9 4107×2×1.5 0.7 1.5 18.0 6358×2×1.5 0.7 1.5 19.7 720
12×2×1.5 0.7 1.6 23.8 101516×2×1.5 0.7 1.6 26.6 133019×2×1.5 0.7 1.9 28.3 152524×2×1.5 0.7 2.0 32.6 194532×2×1.5 0.7 2.2 36.1 24751×3×1.5 0.7 1.0 9.5 1602×3×1.5 0.7 1.3 14.0 2853×3×1.5 0.7 1.3 15.5 4254×3×1.5 0.7 1.3 17.0 5257×3×1.5 0.7 1.6 20.9 8308×3×1.5 0.7 1.6 22.5 900
12×3×1.5 0.7 1.8 27.6 134016×3×1.5 0.7 1.9 31.1 177019×3×1.5 0.7 2.0 32.8 202024×3×1.5 0.7 2.2 38.4 26101×2×2.5 0.7 1.0 9.8 1751×3×2.5 0.7 1.2 10.4 205
Instrumentation Cables
64 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S12 RU(c) 250 V
Applications
These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5Nominal Conductor Diameter mm 1.1 1.3 1.6
HFEPR Insulation
Stranded Copper Conductor
SHF2 Sheath
Copper/Polyester Tape + Drain Wire
Instrumentation Cables
65ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9Mutual Capacitance nF/km 80 90 100Nominal Inductance@1KHz MH/km 0.682 0.645 0.632Maximum L/R@1KHz μH/Ω 20 25 35Operating Voltage V 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
2×2×0.75 0.6 1.1 9.4 1604×2×0.75 0.6 1.1 11.5 2157×2×0.75 0.6 1.3 13.6 3008×2×0.75 0.6 1.3 14.7 34012×2×0.75 0.6 1.4 17.6 46516×2×0.75 0.6 1.5 19.7 59519×2×0.75 0.6 1.5 20.7 66524×2×0.75 0.6 1.7 24.1 85032×2×0.75 0.6 2.0 26.7 10652×3×0.75 0.6 1.1 11.0 1703×3×0.75 0.6 1.1 12.1 2354×3×0.75 0.6 1.2 13.1 2807×3×0.75 0.6 1.4 15.7 4108×3×0.75 0.6 1.4 17.5 49012×3×0.75 0.6 1.5 20.6 64516×3×0.75 0.6 1.6 23.1 83519×3×0.75 0.6 1.7 24.3 94024×3×0.75 0.6 1.8 28.2 12102×2×1.0 0.6 1.1 9.9 1904×2×1.0 0.6 1.1 12.3 2557×2×1.0 0.6 1.3 14.7 3708×2×1.0 0.6 1.3 15.7 410
12×2×1.0 0.6 1.5 18.9 56516×2×1.0 0.6 1.6 21.1 73019×2×1.0 0.6 1.7 22.5 830
Instrumentation Cables
66 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
24×2×1.0 0.6 1.8 25.9 105032×2×1.0 0.6 2.1 28.7 13153×3×1.0 0.6 1.1 12.9 2804×3×1.0 0.6 1.3 14.0 3357×3×1.0 0.6 1.5 16.9 500
12×3×1.0 0.6 1.6 22.1 79516×3×1.0 0.6 1.6 24.8 102519×3×1.0 0.6 1.8 26.3 117524×3×1.0 0.6 2.0 30.4 14902×2×1.5 0.7 1.2 11.3 2504×2×1.5 0.7 1.2 14.1 3457×2×1.5 0.7 1.4 17.2 5158×2×1.5 0.7 1.4 18.4 575
12×2×1.5 0.7 1.6 22.4 81016×2×1.5 0.7 1.7 25.0 104519×2×1.5 0.7 1.8 26.4 117524×2×1.5 0.7 1.9 30.7 150532×2×1.5 0.7 2.2 33.9 18902×3×1.5 0.7 1.2 13.5 2653×3×1.5 0.7 1.2 14.9 3804×3×1.5 0.7 1.3 16.3 4657×3×1.5 0.7 1.5 19.8 7058×3×1.5 0.7 1.5 21.5 820
12×3×1.5 0.7 1.7 26.2 114016×3×1.5 0.7 1.8 29.4 147519×3×1.5 0.7 1.9 30.9 167524×3×1.5 0.7 2.1 36.2 2160
Fire Resistant Instrumentation Cables
67ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S3 or S3/S7 BFOU(i) 250V
Applications
These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S3). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S3/S7), coloured grey (blue for intrinsically safe).
Copper Wire Braid
Mica Tape + HFEPR Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF2 Sheath
Copper/Polyester Tape + Drain Wire
Fire Resistant Instrumentation Cables
68 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 85 95 100 110Nominal Inductance@1KHz MH/km 0.731 0.691 0.673 0.629Maximum L/R@1KHz μH/Ω 20 25 35 55Operating Voltage V 250 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×2×0.75 0.6 1.1 1.2 12.1 2252×2×0.75 0.6 1.1 1.3 16.7 4053×2×0.75 0.6 1.1 1.4 17.5 5404×2×0.75 0.6 1.1 1.4 18.6 6105×2×0.75 0.6 1.1 1.5 20.2 7056×2×0.75 0.6 1.1 1.5 21.7 8057×2×0.75 0.6 1.1 1.5 21.7 8308×2×0.75 0.6 1.1 1.6 23.6 9059×2×0.75 0.6 1.1 1.7 25.1 1000
10×2×0.75 0.6 1.1 1.7 26.2 103012×2×0.75 0.6 1.1 1.7 26.8 114514×2×0.75 0.6 1.1 1.8 28.2 120515×2×0.75 0.6 1.1 1.8 30.0 130516×2×0.75 0.6 1.1 1.9 30.6 141518×2×0.75 0.6 1.1 1.9 32.1 147519×2×0.75 0.6 1.2 1.9 32.7 157520×2×0.75 0.6 1.2 2.0 34.1 170021×2×0.75 0.6 1.2 2.0 35.0 1765
Fire Resistant Instrumentation Cables
69ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
23×2×0.75 0.6 1.2 2.0 35.5 189524×2×0.75 0.6 1.2 2.1 37.7 198027×2×0.75 0.6 1.2 2.2 38.7 216530×2×0.75 0.6 1.2 2.2 39.9 233533×2×0.75 0.6 1.2 2.3 41.5 253537×2×0.75 0.6 1.2 2.3 42.7 27251×3×0.75 0.6 1.1 1.1 11.9 2452×3×0.75 0.6 1.1 1.4 15.5 4203×3×0.75 0.6 1.1 1.4 18.4 5804×3×0.75 0.6 1.1 1.4 19.7 6757×3×0.75 0.6 1.1 1.6 23.6 9608×3×0.75 0.6 1.1 1.7 25.0 980
12×3×0.75 0.6 1.3 1.8 29.6 143516×3×0.75 0.6 1.4 1.9 32.6 177019×3×0.75 0.6 1.4 2.1 34.4 198524×3×0.75 0.6 1.8 2.2 39.6 2580
1×2×1.0 0.6 1.1 1.2 12.5 2452×2×1.0 0.6 1.1 1.4 17.6 4503×2×1.0 0.6 1.1 1.4 18.3 6004×2×1.0 0.6 1.1 1.4 19.3 6255×2×1.0 0.6 1.1 1.5 21.1 9206×2×1.0 0.6 1.1 1.6 22.8 9507×2×1.0 0.6 1.1 1.6 22.8 8608×2×1.0 0.6 1.1 1.6 24.7 9859×2×1.0 0.6 1.1 1.7 26.3 1135
10×2×1.0 0.6 1.1 1.7 27.4 117012×2×1.0 0.6 1.1 1.8 28.3 130014×2×1.0 0.6 1.1 1.8 29.5 138015×2×1.0 0.6 1.1 1.9 31.6 151016×2×1.0 0.6 1.1 1.9 32.1 162018×2×1.0 0.6 1.2 2.0 34.2 174519×2×1.0 0.6 1.2 2.0 34.5 183020×2×1.0 0.6 1.2 2.1 36.0 197521×2×1.0 0.6 1.2 2.1 37.3 213523×2×1.0 0.6 1.2 2.1 37.9 229524×2×1.0 0.6 1.2 2.2 39.8 233527×2×1.0 0.6 1.2 2.2 40.6 250030×2×1.0 0.6 1.2 2.3 42.1 272033×2×1.0 0.6 1.2 2.3 43.6 294037×2×1.0 0.6 1.4 2.4 45.4 3230
Fire Resistant Instrumentation Cables
70 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
1×3×1.0 0.6 1.1 1.2 12.6 2752×3×1.0 0.6 1.1 1.4 18.8 6403×3×1.0 0.6 1.1 1.5 19.3 6654×3×1.0 0.6 1.1 1.5 20.9 7755×3×1.0 0.6 1.1 1.6 22.8 9656×3×1.0 0.6 1.1 1.7 25.4 11357×3×1.0 0.6 1.1 1.7 25.4 11808×3×1.0 0.6 1.1 1.7 27.0 12709×3×1.0 0.6 1.1 1.8 28.9 1450
10×3×1.0 0.6 1.1 1.9 31.1 145512×3×1.0 0.6 1.1 1.9 32.0 168514×3×1.0 0.6 1.2 2.0 33.8 182015×3×1.0 0.6 1.2 2.0 34.8 193516×3×1.0 0.6 1.2 2.1 36.0 210518×3×1.0 0.6 1.2 2.1 38.1 231019×3×1.0 0.6 1.2 2.2 38.6 235520×3×1.0 0.6 1.2 2.2 39.6 259021×3×1.0 0.6 1.2 2.2 40.4 268523×3×1.0 0.6 1.2 2.3 42.0 293524×3×1.0 0.6 1.2 2.3 42.8 314527×3×1.0 0.6 1.4 2.4 45.3 325530×3×1.0 0.6 1.4 2.5 47.4 356532×3×1.0 0.6 1.4 2.5 48.6 37551×2×1.5 0.7 1.1 1.2 13.5 2952×2×1.5 0.7 1.1 1.4 19.2 5453×2×1.5 0.7 1.1 1.5 20.2 7254×2×1.5 0.7 1.1 1.5 21.5 7705×2×1.5 0.7 1.1 1.6 23.4 9756×2×1.5 0.7 1.1 1.7 25.4 11307×2×1.5 0.7 1.1 1.7 25.4 11708×2×1.5 0.7 1.1 1.7 27.5 12259×2×1.5 0.7 1.1 1.8 29.4 1405
10×2×1.5 0.7 1.1 1.9 30.9 144012×2×1.5 0.7 1.1 1.9 31.6 168014×2×1.5 0.7 1.2 2.0 33.6 175015×2×1.5 0.7 1.2 2.1 36.0 191016×2×1.5 0.7 1.2 2.1 36.9 205518×2×1.5 0.7 1.2 2.2 38.9 226019×2×1.5 0.7 1.2 2.2 39.3 239520×2×1.5 0.7 1.2 2.2 40.8 2540
Fire Resistant Instrumentation Cables
71ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
21×2×1.5 0.7 1.2 2.3 42.1 266023×2×1.5 0.7 1.2 2.3 42.7 286524×2×1.5 0.7 1.4 2.4 45.2 308027×2×1.5 0.7 1.4 2.4 46.1 315530×2×1.5 0.7 1.4 2.5 47.8 344032×2×1.5 0.7 1.4 2.6 49.0 368533×2×1.5 0.7 1.4 2.6 49.7 374037×2×1.5 0.7 1.4 2.6 51.2 40401×3×1.5 0.7 1.1 1.3 13.6 3252×3×1.5 0.7 1.1 1.5 18.5 5603×3×1.5 0.7 1.1 1.5 21.4 8004×3×1.5 0.7 1.1 1.6 23.7 9755×3×1.5 0.7 1.1 1.7 25.4 11956×3×1.5 0.7 1.1 1.8 28.3 14057×3×1.5 0.7 1.1 1.8 28.3 14708×3×1.5 0.7 1.1 1.8 30.2 15859×3×1.5 0.7 1.2 1.9 32.6 1835
10×3×1.5 0.7 1.2 2.0 35.1 193512×3×1.5 0.7 1.2 2.1 36.8 211514×3×1.5 0.7 1.2 2.1 38.3 236015×3×1.5 0.7 1.2 2.2 39.7 253016×3×1.5 0.7 1.2 2.2 40.8 277518×3×1.5 0.7 1.2 2.3 42.9 290519×3×1.5 0.7 1.2 2.3 43.3 320020×3×1.5 0.7 1.4 2.4 44.9 330521×3×1.5 0.7 1.4 2.4 45.8 343023×3×1.5 0.7 1.4 2.5 47.7 375524×3×1.5 0.7 1.4 2.5 48.6 392527×3×1.5 0.7 1.4 2.6 51.1 411530×3×1.5 0.7 1.4 2.7 53.5 451032×3×1.5 0.7 1.6 2.8 55.5 48501×2×2.5 0.7 1.1 1.3 14.0 3402×2×2.5 0.7 1.1 1.5 18.5 5603×2×2.5 0.7 1.1 1.5 21.6 8654×2×2.5 0.7 1.1 1.6 23.2 10105×2×2.5 0.7 1.1 1.7 25.3 11856×2×2.5 0.7 1.1 1.7 27.4 13707×2×2.5 0.7 1.1 1.7 27.4 14308×2×2.5 0.7 1.1 1.8 29.9 15609×2×2.5 0.7 1.1 1.9 31.9 1780
Fire Resistant Instrumentation Cables
72 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
10×2×2.5 0.7 1.2 2.0 33.8 177512×2×2.5 0.7 1.2 2.0 34.6 196514×2×2.5 0.7 1.2 2.1 36.9 227515×2×2.5 0.7 1.2 2.2 39.5 248016×2×2.5 0.7 1.2 2.2 40.1 259018×2×2.5 0.7 1.2 2.3 42.3 282519×2×2.5 0.7 1.2 2.3 42.7 293020×2×2.5 0.7 1.4 2.4 44.8 324021×2×2.5 0.7 1.4 2.4 46.1 337523×2×2.5 0.7 1.4 2.5 46.9 356024×2×2.5 0.7 1.4 2.5 49.1 366027×2×2.5 0.7 1.4 2.6 50.3 400030×2×2.5 0.7 1.4 2.7 52.2 437033×2×2.5 0.7 1.4 2.7 54.1 473537×2×2.5 0.7 1.6 2.8 56.4 52251×3×2.5 0.7 1.1 1.2 14.5 3802×3×2.5 0.7 1.1 1.6 22.5 9503×3×2.5 0.7 1.1 1.6 23.4 10554×3×2.5 0.7 1.1 1.7 25.3 12505×3×2.5 0.7 1.1 1.7 27.4 14606×3×2.5 0.7 1.1 1.9 30.7 17357×3×2.5 0.7 1.1 1.9 30.7 18308×3×2.5 0.7 1.2 2.0 33.3 20259×3×2.5 0.7 1.2 2.0 35.4 2290
10×3×2.5 0.7 1.2 2.2 38.8 240512×3×2.5 0.7 1.2 2.2 40.0 268514×3×2.5 0.7 1.2 2.3 41.9 300015×3×2.5 0.7 1.2 2.3 43.1 319016×3×2.5 0.7 1.4 2.4 44.9 342018×3×2.5 0.7 1.4 2.5 47.2 374019×3×2.5 0.7 1.4 2.5 47.6 388520×3×2.5 0.7 1.4 2.5 48.9 418521×3×2.5 0.7 1.4 2.6 50.0 437023×3×2.5 0.7 1.4 2.7 52.1 476024×3×2.5 0.7 1.4 2.7 53.0 478527×3×2.5 0.7 1.6 2.8 56.2 533530×3×2.5 0.7 1.6 2.9 58.8 585532×3×2.5 0.7 1.6 3.0 60.6 6215
Fire Resistant Instrumentation Cables
73ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S4 or S4/S8 BFOU(c) 250V
Applications
These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S4). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S4/S8), coloured grey (blue for intrinsically safe).
Copper Wire Braid
Mica Tape + HFEPR Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF2/SHF MUD Sheath
Copper/Polyester Tape + Drain Wire
Fire Resistant Instrumentation Cables
74 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 75 80 85 95Nominal Inductance@1KHz MH/km 0.727 0.686 0.667 0.623Maximum L/R@1KHz μH/Ω 20 25 35 55Operating Voltage V 250 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer1×2×0.75 0.6 1.1 1.2 12.1 2302×2×0.75 0.6 1.1 1.3 16.4 3403×2×0.75 0.6 1.1 1.4 17.2 4954×2×0.75 0.6 1.1 1.4 18.2 5555×2×0.75 0.6 1.1 1.5 19.8 6406×2×0.75 0.6 1.1 1.5 21.2 7257×2×0.75 0.6 1.1 1.5 21.2 7408×2×0.75 0.6 1.1 1.6 23.1 8059×2×0.75 0.6 1.1 1.6 24.3 880
10×2×0.75 0.6 1.1 1.7 25.6 90012×2×0.75 0.6 1.1 1.7 26.2 95014×2×0.75 0.6 1.1 1.7 27.3 103515×2×0.75 0.6 1.1 1.8 29.2 113016×2×0.75 0.6 1.1 1.8 29.7 117518×2×0.75 0.6 1.1 1.9 31.3 127519×2×0.75 0.6 1.1 1.9 31.6 131520×2×0.75 0.6 1.2 2.0 33.3 147521×2×0.75 0.6 1.2 2.0 34.1 153023×2×0.75 0.6 1.2 2.0 34.6 163524×2×0.75 0.6 1.2 2.1 36.8 1730
Fire Resistant Instrumentation Cables
75ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer27×2×0.75 0.6 1.2 2.1 37.5 185030×2×0.75 0.6 1.2 2.2 38.9 196533×2×0.75 0.6 1.2 2.2 40.3 215537×2×0.75 0.6 1.2 2.3 41.7 23251×3×0.75 0.6 1.1 1.2 12.6 2552×3×0.75 0.6 1.1 1.4 17.7 5453×3×0.75 0.6 1.1 1.4 18.3 5854×3×0.75 0.6 1.1 1.5 19.7 6705×3×0.75 0.6 1.1 1.5 21.2 7706×3×0.75 0.6 1.1 1.6 23.5 9007×3×0.75 0.6 1.1 1.6 23.5 9358×3×0.75 0.6 1.1 1.7 25.2 10159×3×0.75 0.6 1.1 1.7 26.7 113510×3×0.75 0.6 1.1 1.8 28.7 114012×3×0.75 0.6 1.1 1.8 29.6 123014×3×0.75 0.6 1.1 1.9 31.0 137515×3×0.75 0.6 1.1 1.9 31.9 145516×3×0.75 0.6 1.2 2.0 33.3 154518×3×0.75 0.6 1.2 2.0 34.8 169019×3×0.75 0.6 1.2 2.0 35.1 175020×3×0.75 0.6 1.2 2.1 36.6 198521×3×0.75 0.6 1.2 2.1 37.3 205523×3×0.75 0.6 1.2 2.2 38.8 221524×3×0.75 0.6 1.2 2.2 39.5 224527×3×0.75 0.6 1.2 2.3 41.5 243530×3×0.75 0.6 1.2 2.3 43.3 264532×3×0.75 0.6 1.4 2.4 44.9 28401×2×1.0 0.6 1.1 1.2 12.5 2452×2×1.0 0.6 1.1 1.4 17.2 3753×2×1.0 0.6 1.1 1.4 17.9 5504×2×1.0 0.6 1.1 1.4 19.0 6155×2×1.0 0.6 1.1 1.5 20.6 7106×2×1.0 0.6 1.1 1.6 22.4 8207×2×1.0 0.6 1.1 1.6 22.4 8458×2×1.0 0.6 1.1 1.6 24.1 9059×2×1.0 0.6 1.1 1.7 25.7 99510×2×1.0 0.6 1.1 1.7 26.8 103512×2×1.0 0.6 1.1 1.7 27.4 109514×2×1.0 0.6 1.1 1.8 28.9 119515×2×1.0 0.6 1.1 1.9 30.9 130516×2×1.0 0.6 1.1 1.9 31.4 135518×2×1.0 0.6 1.2 2.0 33.4 150019×2×1.0 0.6 1.2 2.0 33.7 1550
Fire Resistant Instrumentation Cables
76 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer20×2×1.0 0.6 1.2 2.0 35.0 168521×2×1.0 0.6 1.2 2.1 36.5 185023×2×1.0 0.6 1.2 2.1 37.0 197524×2×1.0 0.6 1.2 2.2 38.9 199027×2×1.0 0.6 1.2 2.2 39.6 213530×2×1.0 0.6 1.2 2.2 40.9 230033×2×1.0 0.6 1.2 2.3 42.5 249537×2×1.0 0.6 1.4 2.4 44.3 27351×3×1.0 0.6 1.1 1.2 13.0 2802×3×1.0 0.6 1.1 1.4 18.0 5503×3×1.0 0.6 1.1 1.4 18.7 6004×3×1.0 0.6 1.1 1.5 20.0 6905×3×1.0 0.6 1.1 1.6 22.4 8806×3×1.0 0.6 1.1 1.6 24.6 10207×3×1.0 0.6 1.1 1.6 24.6 10608×3×1.0 0.6 1.1 1.7 26.4 11509×3×1.0 0.6 1.1 1.8 28.2 1305
10×3×1.0 0.6 1.1 1.8 30.2 129012×3×1.0 0.6 1.1 1.9 31.3 143514×3×1.0 0.6 1.2 1.9 32.9 160515×3×1.0 0.6 1.2 2.0 34.0 172016×3×1.0 0.6 1.2 2.0 35.0 176518×3×1.0 0.6 1.2 2.1 37.2 205019×3×1.0 0.6 1.2 2.1 37.5 212020×3×1.0 0.6 1.2 2.2 38.7 230021×3×1.0 0.6 1.2 2.2 39.4 238023×3×1.0 0.6 1.2 2.2 40.8 251524×3×1.0 0.6 1.2 2.3 41.7 257527×3×1.0 0.6 1.2 2.3 43.7 281530×3×1.0 0.6 1.4 2.4 46.1 312532×3×1.0 0.6 1.4 2.5 47.5 33101×2×1.5 0.7 1.1 1.3 14.3 3352×2×1.5 0.7 1.1 1.5 20.5 7403×2×1.5 0.7 1.1 1.5 21.2 8054×2×1.5 0.7 1.1 1.6 22.9 9455×2×1.5 0.7 1.1 1.6 24.8 10956×2×1.5 0.7 1.1 1.8 27.8 13007×2×1.5 0.7 1.1 1.8 27.8 13558×2×1.5 0.7 1.1 1.8 29.6 14559×2×1.5 0.7 1.1 1.9 31.7 1660
10×2×1.5 0.7 1.1 2.0 34.4 168012×2×1.5 0.7 1.1 2.0 35.5 185514×2×1.5 0.7 1.2 2.1 37.6 2150
Fire Resistant Instrumentation Cables
77ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer15×2×1.5 0.7 1.2 2.2 38.9 230016×2×1.5 0.7 1.2 2.2 40.0 241518×2×1.5 0.7 1.2 2.3 42.0 263019×2×1.5 0.7 1.2 2.3 42.4 272520×2×1.5 0.7 1.2 2.3 43.5 294021×2×1.5 0.7 1.2 2.4 44.9 311023×2×1.5 0.7 1.2 2.5 46.7 340024×2×1.5 0.7 1.2 2.5 47.5 336027×2×1.5 0.7 1.4 2.6 50.0 371030×2×1.5 0.7 1.4 2.7 52.3 406032×2×1.5 0.7 1.4 2.7 53.8 428533×2×1.5 0.7 1.4 2.5 48.5 324537×2×1.5 0.7 1.4 2.6 50.2 35151×3×1.5 0.7 1.1 1.3 14.3 3352×3×1.5 0.7 1.1 1.5 20.5 7403×3×1.5 0.7 1.1 1.5 21.2 8054×3×1.5 0.7 1.1 1.6 22.9 9455×3×1.5 0.7 1.1 1.6 24.8 10956×3×1.5 0.7 1.1 1.8 27.8 13007×3×1.5 0.7 1.1 1.8 27.8 13558×3×1.5 0.7 1.1 1.8 29.6 14559×3×1.5 0.7 1.1 1.9 31.7 1660
10×3×1.5 0.7 1.2 2.0 34.4 168012×3×1.5 0.7 1.2 2.0 35.5 185514×3×1.5 0.7 1.2 2.1 37.6 215015×3×1.5 0.7 1.2 2.2 38.9 230016×3×1.5 0.7 1.2 2.2 40.0 240518×3×1.5 0.7 1.2 2.3 42.0 263019×3×1.5 0.7 1.2 2.3 42.4 271020×3×1.5 0.7 1.2 2.3 43.5 294021×3×1.5 0.7 1.4 2.4 44.9 311023×3×1.5 0.7 1.4 2.5 46.7 340024×3×1.5 0.7 1.4 2.5 47.5 343027×3×1.5 0.7 1.4 2.6 50.0 371030×3×1.5 0.7 1.4 2.7 52.3 406032×3×1.5 0.7 1.4 2.7 53.8 42851×2×2.5 0.7 1.1 1.3 14.5 3352×2×2.5 0.7 1.1 1.5 20.4 7403×2×2.5 0.7 1.1 1.5 21.3 8004×2×2.5 0.7 1.1 1.6 22.8 9305×2×2.5 0.7 1.1 1.6 24.7 10756×2×2.5 0.7 1.1 1.7 26.9 12457×2×2.5 0.7 1.1 1.7 26.9 1290
Fire Resistant Instrumentation Cables
78 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer8×2×2.5 0.7 1.1 1.8 29.3 14059×2×2.5 0.7 1.1 1.9 31.3 1585
10×2×2.5 0.7 1.2 2.0 33.2 160512×2×2.5 0.7 1.2 2.0 34.0 174514×2×2.5 0.7 1.2 2.0 35.6 192015×2×2.5 0.7 1.2 2.2 38.8 220516×2×2.5 0.7 1.2 2.2 39.4 223018×2×2.5 0.7 1.2 2.3 41.5 250019×2×2.5 0.7 1.2 2.3 41.9 259020×2×2.5 0.7 1.2 2.3 43.5 281521×2×2.5 0.7 1.4 2.4 45.2 299023×2×2.5 0.7 1.4 2.4 45.8 321524×2×2.5 0.7 1.4 2.5 48.2 327027×2×2.5 0.7 1.4 2.6 49.4 351530×2×2.5 0.7 1.4 2.6 51.0 381033×2×2.5 0.7 1.4 2.7 53.1 414537×2×2.5 0.7 1.4 2.8 54.9 45001×3×2.5 0.7 1.1 1.3 15.1 3852×3×2.5 0.7 1.1 1.5 22.0 8803×3×2.5 0.7 1.1 1.6 23.0 9904×3×2.5 0.7 1.1 1.6 24.6 11505×3×2.5 0.7 1.1 1.7 26.9 13506×3×2.5 0.7 1.1 1.8 30.0 15957×3×2.5 0.7 1.1 1.8 30.0 16708×3×2.5 0.7 1.1 1.9 32.2 18209×3×2.5 0.7 1.2 2.0 34.8 210510×3×2.5 0.7 1.2 2.1 37.9 219012×3×2.5 0.7 1.2 2.2 39.2 245514×3×2.5 0.7 1.2 2.2 40.9 271515×3×2.5 0.7 1.2 2.3 42.3 290516×3×2.5 0.7 1.2 2.3 43.5 306018×3×2.5 0.7 1.4 2.4 46.1 338019×3×2.5 0.7 1.4 2.5 46.7 353020×3×2.5 0.7 1.4 2.5 47.9 380021×3×2.5 0.7 1.4 2.5 48.9 395023×3×2.5 0.7 1.4 2.6 50.9 429024×3×2.5 0.7 1.4 2.6 51.8 432527×3×2.5 0.7 1.4 2.7 54.5 474530×3×2.5 0.7 1.6 2.9 57.7 530032×3×2.5 0.7 1.6 2.9 59.3 5595
Fire Resistant Instrumentation Cables
79ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S13 BU(i) 250 V
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Mica Tape + HFEPR Insulation
Stranded Copper Conductor
SHF2 Sheath
Copper/Polyester Tape + Drain Wire
Fire Resistant Instrumentation Cables
80 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 85 95 100 110Nominal Inductance@1KHz MH/km 0.731 0.691 0.673 0.629Maximum L/R@1KHz μH/Ω 20 25 35 55Operating Voltage V 250 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×2×0.75 0.6 1.0 8.2 1052×2×0.75 0.6 1.2 10.5 2054×2×0.75 0.6 1.2 13.2 2907×2×0.75 0.6 1.4 16.0 4458×2×0.75 0.6 1.4 17.3 495
12×2×0.75 0.6 1.6 21.1 70516×2×0.75 0.6 1.7 23.5 91519×2×0.75 0.6 1.8 24.8 103524×2×0.75 0.6 1.9 28.6 132032×2×0.75 0.6 2.0 31.7 16701×3×0.75 0.6 1.0 8.6 1202×3×0.75 0.6 1.2 12.0 2053×3×0.75 0.6 1.2 13.8 3004×3×0.75 0.6 1.3 15.1 3657×3×0.75 0.6 1.5 18.3 5608×3×0.75 0.6 1.5 19.5 650
12×3×0.75 0.6 1.7 24.4 91516×3×0.75 0.6 1.8 27.3 118519×3×0.75 0.6 1.9 29.0 136024×3×0.75 0.6 2.1 33.7 1750
Fire Resistant Instrumentation Cables
81ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×2×1.0 0.6 1.0 8.6 1252×2×1.0 0.6 1.2 11.1 2404×2×1.0 0.6 1.3 14.0 3457×2×1.0 0.6 1.5 16.9 5258×2×1.0 0.6 1.5 18.5 600
12×2×1.0 0.6 1.6 22.3 84016×2×1.0 0.6 1.6 24.9 109519×2×1.0 0.6 1.8 26.5 125524×2×1.0 0.6 1.9 30.5 160532×2×1.0 0.6 2.0 33.8 20301×3×1.0 0.6 1.0 9.1 1403×3×1.0 0.6 1.3 14.7 3604×3×1.0 0.6 1.3 16.1 4407×3×1.0 0.6 1.6 19.7 695
12×3×1.0 0.6 1.7 26.0 111516×3×1.0 0.6 1.8 29.2 145519×3×1.0 0.6 1.9 31.0 167524×3×1.0 0.6 2.1 36.1 21451×2×1.5 0.7 1.0 9.6 1552×2×1.5 0.7 1.3 12.6 3104×2×1.5 0.7 1.4 16.1 4507×2×1.5 0.7 1.6 19.4 6908×2×1.5 0.7 1.6 21.3 780
12×2×1.5 0.7 1.7 25.7 110016×2×1.5 0.7 1.9 28.9 145019×2×1.5 0.7 2.0 30.5 164524×2×1.5 0.7 2.2 35.3 211532×2×1.5 0.7 2.3 39.1 26801×3×1.5 0.7 1.1 10.1 1752×3×1.5 0.7 1.3 14.5 3203×3×1.5 0.7 1.3 16.8 4704×3×1.5 0.7 1.4 18.4 5807×3×1.5 0.7 1.7 22.6 9108×3×1.5 0.7 1.7 23.5 1030
12×3×1.5 0.7 1.9 30.0 147516×3×1.5 0.7 2.0 33.6 192519×3×1.5 0.7 2.1 35.7 221024×3×1.5 0.7 2.4 41.7 28551×2×2.5 0.7 1.1 10.5 1901×3×2.5 0.7 1.3 11.0 220
Fire Resistant Instrumentation Cables
82 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S14 BU(c) 250 V
Applications
These unarmoured cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Mica Tape + HFEPR Insulation
Stranded Copper Conductor
SHF2 Sheath
Copper/Polyester Tape + Drain Wire
Fire Resistant Instrumentation Cables
83ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Nominal Cross Section Area mm² 0.75 1.0 1.5Nominal Conductor Diameter mm 1.1 1.3 1.6Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9Mutual Capacitance nF/km 75 80 85Nominal Inductance@1KHz MH/km 0.727 0.686 0.667Maximum L/R@1KHz μH/Ω 20 25 35Operating Voltage V 250 250 250
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
2×2×0.75 0.6 1.1 10.2 1854×2×0.75 0.6 1.2 12.5 2407×2×0.75 0.6 1.4 15.0 3508×2×0.75 0.6 1.4 16.3 395
12×2×0.75 0.6 1.5 19.5 54016×2×0.75 0.6 1.6 21.8 69019×2×0.75 0.6 1.7 23.2 78024×2×0.75 0.6 1.8 26.7 98532×2×0.75 0.6 2.1 29.6 12252×3×0.75 0.6 1.2 12.0 2053×3×0.75 0.6 1.2 13.1 2654×3×0.75 0.6 1.3 14.4 3207×3×0.75 0.6 1.3 17.4 4758×3×0.75 0.6 1.5 19.5 590
12×3×0.75 0.6 1.6 22.9 74516×3×0.75 0.6 1.7 25.6 96519×3×0.75 0.6 1.8 27.2 109524×3×0.75 0.6 2.0 31.6 14052×2×1.0 0.6 1.1 10.7 210
Fire Resistant Instrumentation Cables
84 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
4×2×1.0 0.6 1.1 13.3 2857×2×1.0 0.6 1.4 16.0 4158×2×1.0 0.6 1.4 17.3 465
12×2×1.0 0.6 1.6 20.8 64516×2×1.0 0.6 1.7 23.3 82519×2×1.0 0.6 1.8 24.7 94024×2×1.0 0.6 1.9 28.8 120032×2×1.0 0.6 2.3 31.8 14953×3×1.0 0.6 1.2 14.0 3104×3×1.0 0.6 1.4 15.3 3807×3×1.0 0.6 1.6 18.6 570
12×3×1.0 0.6 1.6 24.4 90016×3×1.0 0.6 1.7 27.3 116019×3×1.0 0.6 1.9 29.0 132524×3×1.0 0.6 2.1 33.7 17002×2×1.5 0.7 1.2 12.1 2754×2×1.5 0.7 1.3 15.2 3807×2×1.5 0.7 1.5 18.4 5658×2×1.5 0.7 1.5 20.0 640
12×2×1.5 0.7 1.7 24.3 89516×2×1.5 0.7 1.8 27.2 115019×2×1.5 0.7 1.9 28.6 129524×2×1.5 0.7 2.1 33.5 167032×2×1.5 0.7 2.3 37.0 20952×3×1.5 0.7 1.3 15.0 3103×3×1.5 0.7 1.3 16.0 4204×3×1.5 0.7 1.4 17.7 5157×3×1.5 0.7 1.6 21.5 7858×3×1.5 0.7 1.6 23.5 930
12×3×1.5 0.7 1.8 28.5 125516×3×1.5 0.7 1.9 31.9 163019×3×1.5 0.7 2.0 33.8 185524×3×1.5 0.7 2.2 39.3 2375
Fire Resistant Instrumentation Cables
85ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S15 BFOU-HCF(i) 250 V
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency instrumentation, communication, control and alarm systems that need to be operational during a 1100℃ hydrocarbon fire.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2.HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.
SHF2 Sheath
Mica Tape + HFEPR Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF1 Sheath
HC-fire Protection + TapingCopper Wire Braid
Copper/polyester Tape + Drain Wire
Fire Resistant Instrumentation Cables
86 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Outer Sheath2: Flame retardant halogen-free thermoplastic compound, type SHF1, coloured grey (blue for intrinsically safe).
Electrical Characteristics
Nominal Cross Section Area mm² 1.5Nominal Conductor Diameter mm 1.6Maximum Resistant@20℃ Ω/km 12.9Mutual Capacitance nF/km 100Nominal Inductance@1KHz MH/km 0.673Operating Voltage V 250
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 12×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores
in element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over
Beddingmm
Nominal Diameter Over
Sheath1mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×2×1.5 0.7 9.0 13.1 39.5 18802×2×1.5 0.7 13.0 16.8 44.5 24504×2×1.5 0.7 15.0 20.7 47.5 28308×2×1.5 0.7 21.0 26.4 54.0 3690
12×2×1.5 0.7 25.0 31.2 63.0 5200
Fire Resistant Instrumentation Cables
87ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S16 BFOU-HCF(c) 250 V
Applications
These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency instrumentation, communication, control and alarm systems that need to be operational during a 1100℃ hydrocarbon fire.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Circular tinned stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2.HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.
SHF2 Sheath
Mica Tape + HFEPR Insulation
Halogen-free Bedding
Stranded Copper Conductor
SHF1 Sheath
HC-fire Protection + TapingCopper Wire Braid
Copper/polyester Tape + Drain Wire
Fire Resistant Instrumentation Cables
88 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Outer Sheath2: Flame retardant halogen-free thermoplastic compound, type SHF1, coloured grey (blue for intrinsically safe).
Electrical Characteristics
Nominal Cross Section Area mm² 1.5Nominal Conductor Diameter mm 1.6Maximum Resistant@20℃ Ω/km 12.9Mutual Capacitance nF/km 85Nominal Inductance@1KHz MH/km 0.667Operating Voltage V 250
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 12×OD (fixed installed)
Temperature Range: -20℃ ~ +90℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Cross section(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over
Beddingmm
Nominal Diameter Over
Sheath1mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
2×2×1.5 0.7 13.0 16.4 44.5 24004×2×1.5 0.7 15.0 19.9 46.5 26508×2×1.5 0.7 20.5 25.3 53.0 3570
12×2×1.5 0.7 23.5 29.6 57.0 4160
Telecommunication Cables
89ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S9 IYXI(c) 60 V
Applications
These cables are flame retardant, low smoke and halogen free, used for indoor telecommunication.
Standards
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Solid tinned copper, 0.5mm. Insulation: Halogen-free thermoplastic compound PE.Twinning: Colour coded cores twisted together. Pairs are cross-stranded to finished cable or 10 pair units. The units are stranded to 20 - 30 - 50 pair cables. 2 pair is stranded as a star quad.Wrapping: Polyester tape.Collective Shielding: The cable core is screened by copper backed polyester tape in contact with a 0.5mm solid tinned drain wire.Sheath: Halogen-free thermoplastic compound, type SHF1, coloured grey.
Electrical Characteristics
Nominal Conductor Diameter mm 0.5Maximum Resistant@20℃ Ω/km 95Nominal Inductance@1KHz MH/km 0.61Mutual Capacitance 1-pair cable nF/km 90Mutual Capacitance 2-pair cable nF/km 80
Copper/polyester Tape + Drain Wire
Halogen Free PE Insulation
Wrapping Tape
Solid Copper Conductor
SHF1 Sheath
Twisted Pair
Telecommunication Cables
90 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Mutual Capacitance 4-pair and above cable nF/km 70Operating Voltage V 60
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -10℃ ~ +60℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Core diameter(mm)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1×2×0.5 0.2 1.2 5.0 302×2×0.5 0.2 1.2 5.5 354×2×0.5 0.2 1.2 7.0 55
10×2×0.5 0.2 1.5 8.5 9020×2×0.5 0.2 1.5 11.0 14830×2×0.5 0.2 1.5 13.5 21050×2×0.5 0.2 1.5 16.0 320
Telecommunication Cables
91ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
S10 IYOI(c) 60 V
Applications
These cables are flame retardant, low smoke and halogen free, used for indoor telecommunication.
Standards
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: Solid tinned copper, 0.5mm. Insulation: Halogen-free thermoplastic compound PE.Twinning: Colour coded cores twisted together. Pairs are cross-stranded to finished cable or 10 pair units. The units are stranded to 20 - 30 - 50 pair cables. 2 pair is stranded as a star quad.Wrapping: Polyester tape.Collective Shielding: The cable core is screened by copper backed polyester tape in contact with a 0.5mm solid tinned drain wire.Bedding: Halogen-free thermoplastic compound, type SHF1, coloured grey.Armour: Copper wire braidOuter Sheath: Halogen-free thermoplastic compound, type SHF1, coloured grey.
Electrical Characteristics
Nominal Conductor Diameter mm 0.5Maximum Resistant@20℃ Ω/km 95Nominal Inductance@1KHz MH/km 0.61
Copper/polyester Tape + Drain Wire
Halogen Free PE InsulationWrapping Tape
SHF1 Sheath
Solid Copper Conductor
SHF1 Sheath
Copper Wire Braid
Telecommunication Cables
92 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Mutual Capacitance 1-pair cable nF/km 90Mutual Capacitance 2-pair cable nF/km 80Mutual Capacitance 4-pair and above cable nF/km 70Operating Voltage V 60
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 6×OD (fixed installed)
Temperature Range: -10℃ ~ +60℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Core diameter(mm)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer1×2×0.5 0.2 1.2 1.2 8.0 952×2×0.5 0.2 1.2 1.2 9.0 1104×2×0.5 0.2 1.2 1.2 10.0 145
10×2×0.5 0.2 1.5 1.5 12.0 20020×2×0.5 0.2 1.5 1.5 15.0 33030×2×0.5 0.2 1.5 1.5 17.0 43050×2×0.5 0.2 1.5 1.5 20.0 580
Optical Fibre Cables
93ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
F1 QFCI
Applications
These steel armoured optical fibre cables are flame retardant, low smoke, halogen free and fire resistant, used for communication and emergency systems that need to be operational during fire.
Standards
IEC 60794
IEC 60811-2-1
IEC 60331-25
IEC 60332-3-24
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Fibre Element: Loose tube core design. Central Strength Element: Steel wire or fibre reinforced plastic (FRP).Bedding: Halogen free and flame retardant thermoplastic compound.Armour: Galvanized steel wire braid.Outer Sheath: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.
Optional
F4 QFCI-HCF: QFCI-HCF cables are consist of loose tube fibre element, steel wire or FRP central strength element, halogen free and flame retardant thermoplastic bedding, galvanized steel wire braid armour, SHF1 sheath, HC-fire protection, fire resistant tape and SHF1 outer sheath.
Galvanized Steel Wire Braid
Steel Wire/FRP Strength Element
Halogen-free Bedding
Fibre Element
SHF1 Sheath
Optical Fibre Cables
94 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
Fibre Type 9/125 50/125 50/125 62.5/125ITU-T type G652.D G651 G651 -IEC11801 Classification OS1 & OS2 OM2 OM3 OM1Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Cladding Diameter μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Coating Diameter μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Maximum Attenuation
@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -
Minimum Bandwidth(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600
Maximum Chromatic Dispersion1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -
Zero Dispersion Wavelength nm 1300~1324 - - -
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 10×OD (fixed installed)
Temperature Range: -40℃ ~ +70℃
Dimensions and Weight
No. of FibresConstruction
No. of tubes×No. of fibres in each tube
Number of FillersNominal Loose Tube Diameter
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
2 1×2 5 2.2 13.9 2444 1×4 5 2.2 13.9 2446 3×2 3 2.2 13.9 2448 2×4 4 2.2 13.9 244
10 5×2 1 2.2 13.9 24412 3×4 3 2.2 13.9 24416 4×4 2 2.2 13.9 24420 5×4 1 2.2 13.9 24424 6×4 0 2.2 13.9 24432 4×8 2 2.2 13.9 24440 5×8 1 2.2 13.9 24448 6×8 0 2.2 13.9 244
Optical Fibre Cables
95ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
F5 QFCB
Applications
These steel armoured optical f ibre cables are f lame retardant, low smoke, halogen free and fire resistant, used for communication and emergency systems that need to be operational during fire.
Standards
IEC 60794
IEC 60811-2-1
IEC 60331-25
IEC 60332-3-24
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Fibre Element: Loose tube core design. Central Strength Element: Steel wire or fibre reinforced plastic (FRP).Bedding: Halogen free and flame retardant thermoplastic compound.Armour: Galvanized steel wire braid.Outer Sheath1: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.Outer Sheath2: Mud resistant and halogen-free thermoplastic compound.
Electrical Characteristics
Fibre Type 9/125 50/125 50/125 62.5/125ITU-T type G652.D G651 G651 -IEC11801 Classification OS1 & OS2 OM2 OM3 OM1
Galvanized Steel Wire Braid
Steel Wire/FRP Strength ElementHalogen-free Bedding
Fibre Element
SHF1 Sheath
Mud Resistant & Halogen Free Sheath
Optical Fibre Cables
96 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Cladding Diameter μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Coating Diameter μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Maximum Attenuation
@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -
Minimum Bandwidth(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600
Maximum Chromatic Dispersion1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -
Zero Dispersion Wavelength nm 1300~1324 - - -
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 10×OD (fixed installed)
Temperature Range: -40℃ ~ +70℃
Dimensions and Weight
No. of FibresConstruction
No. of tubes×No. of fibres in each tube
Number of FillersNominal Loose Tube Diameter
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
2 1×2 5 2.2 15.0 2904 1×4 5 2.2 15.0 2906 3×2 3 2.2 15.0 2908 2×4 4 2.2 15.0 290
10 5×2 1 2.2 15.0 29012 3×4 3 2.2 15.0 29016 4×4 2 2.2 15.0 29020 5×4 1 2.2 15.0 29024 6×4 0 2.2 15.0 29032 4×8 2 2.2 15.0 29040 5×8 1 2.2 15.0 29048 6×8 0 2.2 15.0 290
Optical Fibre Cables
97ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
F6 AICI
Applications
These optical fibre cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, data and communication systems.
Standards
IEC 60794
IEC 60811-2-1
IEC 60331-25
IEC 60332-3-24
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Fibre Element: Tight buffered fibres. Central Strength Element: Fibre reinforced plastic (FRP) and/or aramid yarns.Bedding: Halogen free and flame retardant thermoplastic compound.Armour: Galvanized steel wire braid.Outer Sheath: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.
Electrical Characteristics
Fibre Type 9/125 50/125 50/125 62.5/125ITU-T type G652.D G651 G651 -IEC11801 Classification OS1 & OS2 OM2 OM3 OM1
Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Cladding Diameter μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0
Galvanized Steel Wire Braid
Aramid Yarns
Halogen-free Bedding
Fibre Element
SHF1 Sheath
Optical Fibre Cables
98 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Coating Diameter μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Maximum Attenuation
@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -
Minimum Bandwidth(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600
Maximum Chromatic Dispersion1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -
Zero Dispersion Wavelength nm 1300~1324 - - -
Mechanical and Thermal Properties
Bending Radius: 20×OD (during installation); 10×OD (fixed installed)
Temperature Range: -40℃ ~ +70℃
Dimensions and Weight
No. of FibresSecondary Coating
mmNominal Overall Diameter
mmNominal Weight
kg/km
2 0.9 7.8 1004 0.9 8.2 1108 0.9 9.4 12512 0.9 10.3 14524 0.9 12.0 185
Data Cables
99ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Cat5E UTP/FTP Armoured Data Cable
Applications
Cat5E Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.
Standards
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 24AWG solid bare copper. Insulation: HDPE.Twinning: Two coloured insulated conductors twisted together to form a pair.Bedding: Flame retardant, low smoke and halogen-free polyolefin, coloured black.Armour: 0.2/0.3mm copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Optional
Cat5E F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat5E SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.
Copper Wire Braid
HDPE Insulation
FRLSZH Polyolefin Bedding
Solid Copper Conductor
LSZH Polyolefin Sheath
Twisted Pair
Data Cables
100 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
AWG 24Nominal Conductor Diameter mm 0.53Maximum DC Resistant@20℃ Ω/100m 9.38Maximum DCR Unbalance % 5Maximum Mutual Capacitance pF/m 55.8Maximum Capacitance Unbalance pF/100m 330Characteristic Impedance@1-100MHz Ω 100+/-15Maximum Propagation Delay Skew ns/100m 45
FREQMHz
Maximum AttenuationdB/100m
Minimum NEXT
dB
Minimum PSNEXT
dB
Minimum ELFEXTdB/100m
Minimum PSELFEXTdB/100m
Minimum RLdB
0.772 1.8 67.0 64.0 66.0 63.0 —1 2.0 65.3 62.3 63.8 60.8 20.04 4.1 56.3 53.3 51.7 48.7 23.08 5.8 51.8 48.8 45.7 42.7 24.510 6.5 50.3 47.3 43.8 40.8 25.016 8.2 47.3 44.3 39.7 36.7 25.020 9.3 45.8 42.8 37.7 34.7 25.025 10.4 44.3 41.3 35.8 32.8 24.3
31.25 11.7 42.9 39.9 33.9 30.9 23.662.5 17.0 38.4 35.4 27.8 24.8 21.5100 22.0 35.3 32.3 23.8 20.8 20.1
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
Temperature Range: -30℃ ~ +75℃
Copper Wire Braid
HDPE Insulation
FRLSZH Polyolefin Bedding
Solid Copper Conductor
LSZH Polyolefin Sheath
AL/polyester Tape + Drain Wire
Data Cables
101ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Conductor diameter(mm)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
4×2×0.53 0.2 0.8 1.14 10.1 179
Data Cables
102 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Cat6 UTP/FTP Armoured Data Cable
Applications
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.
Standards
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 23AWG solid bare copper. Insulation: HDPE.Twinning: Two coloured insulated conductors twisted together to form a pair.Bedding: Flame retardant, low smoke and halogen-free polyolefin, coloured black.Armour: 0.2/0.3mm copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Optional
Cat6 F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.
Copper Wire Braid
HDPE InsulationFRLSZH Polyolefin Bedding
Solid Copper ConductorLSZH Polyolefin Sheath
Twisted Pair
Data Cables
103ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Characteristics
AWG 23Nominal Conductor Diameter mm 0.58Maximum DC Resistant@20℃ Ω/100m 9.38Maximum DCR Unbalance % 3Maximum Mutual Capacitance pF/m 5.8Maximum Capacitance Unbalance pF/100m 30Characteristic Impedance@1-100MHz Ω 100+/-15Maximum Propagation Delay Skew ns/100m 18
FREQMHz
Maximum AttenuationdB/100m
Minimum NEXT
dB
Minimum PSNEXT
dB
Minimum ELFEXTdB/100m
Minimum PSELFEXTdB/100m
Minimum RLdB
0.772 1.8 76.0 74.0 70.0 67.0 —1 2.0 74.3 72.3 67.8 64.8 20.04 3.8 65.3 63.3 55.7 52.7 23.08 5.3 60.8 58.8 49.7 46.7 24.5
10 6.0 59.3 57.3 47.8 44.8 25.016 7.6 56.3 54.3 43.7 40.7 25.020 8.5 54.8 52.8 41.7 38.7 25.025 9.5 53.3 51.3 39.8 36.8 24.3
31.25 10.7 51.9 49.9 37.9 34.9 23.662.5 15.4 47.4 45.4 31.8 28.8 21.5100 19.8 44.3 42.3 27.8 24.8 20.1155 25.2 41.5 39.5 23.9 20.9 18.8200 29.0 39.8 37.8 21.7 18.7 18.0250 32.8 38.3 36.3 19.8 16.8 17.3
Copper Wire Braid
HDPE Insulation
FRLSZH Polyolefin Bedding
Solid Copper Conductor
LSZH Polyolefin Sheath
Al/polyester Tape + Drain Wire
Data Cables
104 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
ConstructionNo. of elements×No. of cores in
element×Conductor diameter(mm)
Nominal Insulation Thickness
mm
Nominal Sheath Thicknessmm
Nominal Overall Diameter
mm
Nominal Weightkg/km
Inner Outer
4×2×0.58 0.23 0.8 1.14 11.6 214
Coaxial Cables
105ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
RG6 Armoured Coaxial Cable
Applications
These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 18AWG solid bare copper. Insulation: Foam PE.Shielding1: Al/Polyester/Al tape.Shielding2: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Electrical Characteristics
AWG 18Nominal Conductor Diameter mm 1.0Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 6.9Nominal Attenuation@200MHz dB/100m 9.0Nominal Attenuation@300MHz dB/100m 11.8Nominal Attenuation@400MHz dB/100m 13.1Nominal Attenuation@500MHz dB/100m 15.4Nominal Attenuation@900MHz dB/100m 21.5
Copper Wire BraidFoam PE Insulation
Tinned Copper BraidSolid Copper Conductor
LSZH Polyolefin Sheath
Al/Polyester/Al TapeLSZH Polyolefin Bedding
Coaxial Cables
106 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Nominal Attenuation@1700MHz dB/100m 29.4Capacitance pF/m 53.5Velocity of Propagation % 83Conductor DCR Ω/km 21.4Shield DCR Ω/km 7.5Inductance μH/m 0.32Time Delay ns/m 4
Mechanical and Thermal Properties
Bending Radius: 15×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Nominal Inner Conductor Diameter
mm
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1.0 1.8 1.2 11.2 208
Coaxial Cables
107ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
RG11 Armoured Coaxial Cable
Applications
These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 14AWG solid bare copper. Insulation: Foam PE.Shielding1: Al/Polyester/Al tape.Shielding2: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Electrical Characteristics
AWG 14Nominal Conductor Diameter mm 1.6Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 4.5Nominal Attenuation@270MHz dB/100m 7.6Nominal Attenuation@540MHz dB/100m 10.8Nominal Attenuation@750MHz dB/100m 12.8Nominal Attenuation@1000MHz dB/100m 14.8Capacitance pF/m 53.5
Copper Wire BraidFoam PE Insulation
Tinned Copper BraidSolid Copper Conductor
LSZH Polyolefin Sheath
Al/Polyester/Al TapeLSZH Polyolefin Bedding
Coaxial Cables
108 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Velocity of Propagation % 83Conductor DCR Ω/km 8.5Shield DCR Ω/km 12.1Inductance μH/m 0.32Time Delay ns/m 4
Mechanical and Thermal Properties
Bending Radius: 15×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Nominal Inner Conductor Diameter
mm
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
1.6 2.7 1.7 15.0 353
Coaxial Cables
109ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
RG59 Armoured Coaxial Cable
Applications
These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 20AWG solid bare copper. Insulation: Foam PE.Shielding1: Al/Polyester/Al tape.Shielding2: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Electrical Characteristics
AWG 20Nominal Conductor Diameter mm 0.8Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 7.6Nominal Attenuation@270MHz dB/100m 12.5Nominal Attenuation@540MHz dB/100m 17.9Nominal Attenuation@720MHz dB/100m 20.9Nominal Attenuation@750MHz dB/100m 21.3Nominal Attenuation@1000MHz dB/100m 24.9
Copper Wire BraidFoam PE Insulation
Tinned Copper BraidSolid Copper Conductor
LSZH Polyolefin Sheath
Al/Polyester/Al TapeLSZH Polyolefin Bedding
Coaxial Cables
110 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Capacitance pF/m 53.5Velocity of Propagation % 83Conductor DCR Ω/km 32.8Shield DCR Ω/km 12.5Inductance μH/m 0.318Time Delay ns/m 4.0
Mechanical and Thermal Properties
Bending Radius: 15×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Nominal Inner Conductor Diameter
mm
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
0.8 1.4 1.2 10.0 177
Coaxial Cables
111ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
RG58 Armoured Coaxial Cable
Applications
These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 21AWG tinned copper. Insulation: PE.Shielding: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Electrical Characteristics
AWG 21Conductor Construction No./Diameter of Wires -/mm 19/0.18Nominal Conductor Diameter mm 0.89Impedance Ω 50+/-3 Nominal Attenuation@100MHz dB/100m 15.7Nominal Attenuation@200MHz dB/100m 22.3Nominal Attenuation@400MHz dB/100m 32.8Nominal Attenuation@700MHz dB/100m 46.6Nominal Attenuation@900MHz dB/100m 54.1Nominal Attenuation@1000MHz dB/100m 56.1
Copper Wire Braid
PE Insulation
Tinned Copper Braid
Stranded Copper Conductor
LSZH Polyolefin Sheath
LSZH Polyolefin Bedding
Coaxial Cables
112 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Capacitance pF/m 101Velocity of Propagation % 66Conductor DCR Ω/km 35.4Inductance μH/m 0.246Time Delay ns/m 5.0
Mechanical and Thermal Properties
Bending Radius: 15×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Nominal Inner Conductor Diameter
mm
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
0.89 1.0 1.14 8.6 149
Coaxial Cables
113ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
RG213 Armoured Coaxial Cable
Applications
These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
IEC 60092-350
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
Conductors: 13AWG bare copper. Insulation: PE.Shielding: Copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.
Electrical Characteristics
AWG 13Conductor Construction No./Diameter of Wires -/mm 7/0.75Nominal Conductor Diameter mm 2.24Impedance Ω 50+/-3 Nominal Attenuation@100MHz dB/100m 7.5Nominal Attenuation@200MHz dB/100m 10.5Nominal Attenuation@400MHz dB/100m 15.1Nominal Attenuation@1000MHz dB/100m 29.5Capacitance pF/m 101Velocity of Propagation % 66
Copper Wire Braid
PE Insulation
Tinned Copper Braid
Stranded Copper Conductor
LSZH Polyolefin Sheath
LSZH Polyolefin Bedding
Coaxial Cables
114 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Conductor DCR Ω/km 5.7Shield DCR Ω/km 3.9Inductance μH/m 0.246Time Delay ns/m 5.0
Mechanical and Thermal Properties
Bending Radius: 15×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Nominal Inner Conductor Diameter
mm
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weightkg/km
2.24 2.2 1.14 13.9 379
Coaxial Cables
115ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Mud Resistant Composite Cable
Applications
These composite cables consist of cat6 data cable & coaxial cable & power cable, with copper wire braid armoured & flame retardant oil&mud resistant outer sheath.
Standards
IEC 60092-359
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
Construction
1) 4×2×0.57mm U/UTP Cat6 Data Cable: Conductors: Solid bare copper wire. Insulation: PE.Twinning: Two coloured insulated wire twisted to form a pair.Sheath: Flame retardant LSZH, coloured grey.
2) RG59 Coaxial Cable: Conductors: 0.58mm solid bare copper wire.Insulation: PE.Shielding: Bare copper wire braid.Sheath: Flame retardant LSZH, coloured grey.
3) 3×1.0mm² Power Cable: Conductors: 7/0.44mm stranded bare copper wire. Insulation: XLPE. Coloured Blue, Brown, Green/Yellow.She ath: Flame retardant LSZH, coloured grey
4) Element AssemblyFiller: PP, PVC, PE or LSZH Material.Wrapping: Polyester Tape.
Copper Wire Braid
Polyester TapeCoaxial Cable Element
Power Cable Element
Flame Retardant LSZH Sheath
Data Cable Element
Flame Retardant LSZH Bedding
Coaxial Cables
116 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Bedding: Flame retardant LSZH.Armour: Tinned copper wire braid.Outer Sheath: Oil & mud resistant, flame retardant LSZH, coloured grey.
Dimensions
Cable ConstructionNominal Data Cable
Diameter mm
Nominal Coaxial Cable Diameter
mm
Nominal Power Cable Diameter
mm
Nominal Overall Diameter
mm4×2×0.57mm + RG59 + 3×1.0mm² 6.0 6.2 6.8 21.0
Note: Other construction can be offered opon request.
Technical Information
117ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Cable Code DesignationA cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction.For example:
1st Letter: Insulation:B: Fire resistant tape + insulation (Halogen-free)R: Ethylene propylene rubber - EPR T: Cross-linked polyethylene XLPE I: Thermoplastic compound (Halogen-free) U: Halogen-free thermosetting compound EMA or EVA A: Fibre, tight buffered Q: Fibre in loose tube
2nd letter:Inner Sheath:F: Bedding/Inner covering or taping (Halogen-free) Y: Screen (poss. with PE or PP) I: Thermoplastic compound (Halogen-free) SHF1
3rd letter:Armour/Screen:L: Aluminium (laminated to outer sheath) X: No armour O: Copper wire braid (Tinned or bare) A: Strength member of yarn C: Galvanized steel wire braid
4rd letter:Outer Sheath:I: Thermoplastic compound (Halogen-free), SHF1 U: Halogen-free thermosetting compound, SHF2 U: Halogen-free mud resistant thermosetting compound, SHF Mud B*: Halogen-free mud resistant thermoplastic compound *QFCB cables only
Additional Abbreviation for Instrumentation Cables: (c): Collective screen(i): Individual pair or triple screen
RFOU(i)
Technical Information
118 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Standards and Tests
NEK 606-2004 Cables for Offshore Installations halogen-free and/or mud resistant
IEC 60092-350 Electrical installations in ships Part 350: Low-voltage shipboard power cables.
(General construction and test requirements)IEC 60092-351 Electrical installations in ships Part 351: Insulating materials for shipboard power cablesIEC 60092-352 Electrical installations in ships Part 352: Choice and installation of electric cables for
low voltage power systemsIEC 60092-353 Electrical installations in ships Part 353: Single and multicore cables with extruded
solid insulation for rated voltages 0,6/1 and 1,8/3 kVIEC 60092-354 Electrical installations in ships Part 354: Single and three-core power cables with extruded
solid insulation for rated voltages 6 kV up to 30 kV.IEC 60092-359 Electrical installations in ships Part 359: Sheathing materials for shipboard power and
telecommunication cablesIEC 60092-375 Electrical installations in ships Part 375: General instrumentation, control and
communication cablesIEC 60092-376 Electrical installations in ships Part 376: 150/250 V cables for Control and
instrumentation CircuitsIEC 60228 Conductors of insulated cablesIEC 60331-11/12/21/25/31 Fire resisting characteristics of electrical cablesIEC 60332-1/3 Tests on electric cables under fire condition. Part 1: Tests on a single vertical insulated wire or cable. Part 3: Test on bunched wires or cables.IEC 60446 Basic and safety principles for man-machine interface,
marking and identification. Identification of conductors by colours or alphanumericsIEC 60754-1/2 Test on gases evolved during combustion of electric cables IEC 60811 Common test methods for insulating and sheathing
materials of electric cables
IEC 61034-1/2 Measurement of smoke density of electric cables burning under defined conditions. Part 1: Test apparatus Part 2: Test procedure and requirements
Technical Information
119ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Cable Characteristics
Mud Resistant
The suitability of sheathing materials for use in areas in which the cables are exposed to drilling fluids is heavily dependent upon the type of fluid present. Each type of fluid contains additives which can have a deleterious effect on the sheathing material.
According to NEK 606, the mud resistant cables shall have a SHF Mud sheath that comply with the requirements in IEC 60092-359 for SHF2 and the below specified. The mud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD unless otherwise specified.
The MUD resistance test requirements for sheathing compounds SHF Mud are as follows:
Test fluid Temperature DurationTensile Strength & Elongation At Break Variation
Volume Swell Variation
Weight Increase Variation
Mineral oil type - IRM 903
100℃ 7 d 30% 30% 30%
Calcium Bromide Brine (Waterbased)
70℃ 56 d 25% 20% 15%
Carbo Sea (oil based)
70℃ 56 d 25% 20% 15%
Oil Resistance
All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be demonstrated by a test according to IEC 60092-359 SHF2.
Flame Retardance
The cables shall withstand the test specified in IEC 60332-3-10, -22, -23, -24, -25. Single, earth and bonding wires shall withstand the test specified in IEC 60332-1 or IEC 60332-2.
Fire Resistance
Fire resistance cables shall be tested according to IEC 60331-11, -12, -21, -25 and -31.
Technical Information
120 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Hydrocarbon (HCF) Fire Resistant
The purchaser shall specify which of the curves below in Figure 1 or 2 to comply with the HCF test.
The test requires no breakdown for 30 or 60 minutes when connected to operating voltage. Time to breakdown to be considered in agreement with the customer or approval authority.
Content of Halogen
All cables shall be halogen-free according to IEC 60754-1/2.
Smoke Emission
During a cable fire smoke emission shall be kept to a minimum value of 60% according to IEC 61034-1/2.
Fig.1 HC fire curve based on Exxon calcula�ons, which required func�onal security
for 15 minutes
Time in minutes exposed to fire
Fig.2 Interna�onal recognized HC fire curve.
Time in minutes exposed to fire
Tem
pera
ture
in d
eg.C
Tem
pera
ture
in d
eg.C
20
600
820
10001050 1083 1100 1100
20
743
880945
1033 1071 1098 1100
0 10 20 30 40 50 60
0 10 20 30 40 50 60
Technical Information
121ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Electrical Data
Conductor Resistance
Resistance formula:
R ALt= [Ω]
p=specificresistance,Ω.mm²/mA=conductorarea,mm²L=conductorlength,m
Resistance as a function of temperature:
1 20R R t0 a= + -] g7 A
R0= Resistance at t=20℃t = conductor temperature ℃α=0.00393forcopper
Short circuit ratings
The following short circuit currents are for cables normally operating at a maximum conductortemperatureof90°C.
The theoretical temperature thatarises in theconductorduringashortcircuit,whichisusedasabasisof thecalculation, is250℃. EPR and XLPE insulation are capable of withstandingshorttermtemperaturesupto250°C.
The short circuit currents for copper conductors given in the table are values for one second,forotherdurationsthecurrentmaybecalculatedfromthefollowingformula:
I It
=
It=short ciricut current for t sec.(Amp)l=short circuit current for one sec.(Amp)t=short circuit duration(sec.)The duration of the short circuit based on these assumptions should be between 0.2 sec.
and5sec.
Technical Information
122 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Conductor area mm²
Current 1 second amperes
Conductor area mm²
Current 1 second amperes
Conductor area mm²
Current 1 second amperes
Conductor area mm²
Current 1 second amperes
1.0 140 10 1400 70 9800 240 336001.5 210 16 2240 95 13300 300 420002.5 350 25 3500 120 16800 400 560004 560 35 4900 150 21000 500 700006 840 50 7000 185 25900 630 88200
Reactance
ThereactanceofacableoperatinginanACsystemdependsonmanyfactors,including,inparticular,theaxialspacingbetweenconductorsandtheproximityandmagneticpropertiesofadjacentsteelwork.Theformerisknownformulticorecable,butmayvaryforsinglecorecables depending upon the spacing between them and their disposition when installed.
Reactance of cables in certain dispositions remote from steelwork is calculable and is shown. The values are for cables with circular conductors.
Thevalueforasector-shapedconductorshouldbetakenas90%ofthecalculatedvalue.Inductionfor2-,3-and4-conductorcablesisgivenbytheformula:
0.2 2 0.25 10lnL ad
6# #= + -a k: D [H/m]a = Axial space between conductors in mm.d = conductor diameter in mm.
Reactancefor2-,3-and4-conductorcablesisgivenbytheformula:
2X fLIr= [Ω]f = frequency in HzL=InductioninH/mI=Conductorlengthinm
Impedance
Inductionfor2-,3-and4-conductorcablesisgivenbytheformula:
Z R X2 23= +^ h [Ω]R=ResistanceatoperatingtempratureinΩX=ReactanceinΩ
Technical Information
123ADDISONwww.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Core Identification
The identification of insulated conductors (cores) for the 250 V cables Cable element Colour of cores
Pair Black Light blueTriple Black Light blue Brown
Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors
The identification of insulated conductors (cores) for the 0.6/1 kV cables according to NEK standard
No. of cores Colour of coresSingle core Off-white(grey)Two cores Off-white(grey) Black
Three cores Off-white(grey) Black RedFour cores Off-white(grey) Black Red Blue
above 4 cores black numbers on white baseearthing core yellow/green
The identification of insulated conductors (cores) for the 0.6/1 kV cables according to standard HD 308 S2
Cables with a green/yellow coreNo. of cores Colour of cores*Three cores Green/yellow Blue BrownFour cores** Green/yellow - Brown Black GreyFour cores Green/yellow Blue Brown BlackFive cores Green/yellow Blue Brown Black Grey
** For certain applications only.* In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wires, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.
Cables without a green/yellow coreNo. of cores Colour of cores*Two cores Blue Brown
Three cores** - Brown Black GreyThree cores Blue Brown BlackFour cores Blue Brown Black GreyFive cores Blue Brown Black Grey Black
** For certain applications only.* In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wires, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.
The identification of insulated conductors (cores) for the 3.6/6kV, 6/10kV, 8.7/15kV,12/20kV and 18/30kV cables
No. of cores Colour of coresSingle core off-white insulation + black semi conducting layers
Three coresoff-white insulation + black semi conducting layers identified by White-Black-Red threads under
and over the metallic screen on each individual core.earthing core yellow/green
Power and Control Cables
124 ADDISON www.addison-cables.com
NEK606 Caledonian Offshore & Marine Cables
www.caledonian-cables.co.uk
Caledonian Offshore & Marine Cables
NEK606 STANDARD
www.caledonian-cables.co.ukwww.addison-cables.ccom
Caledonian
UNITED KINGDOM
Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UKTel: 44 (0) 207 419 5087Fax: 44 (0) 207 831 9489Email: [email protected]
HONG KONG
Unit B 22/F CMA Building, 64-66 Connaught Road Central, Hong KongTel: 852 36527508Fax: 852 35834834Email: [email protected]