Copyright ©2015 SunShine Communication Technology Co., Ltd Copyright, infringement
Outdoor Cabinet Solution
2
3
4
Outdoor Cabinets Applications in Telecom Network
Sunshine Outdoor Cabinet Solution Introduction
Reference Cases
1 Company Introduction
Business Scopes
Base Station solutions
Underground System
Enterprise&Data center solutionsConnectivity
solutions
one-stopPlanning & Design , Solution & Products ,Deployment & Services
Metal Sheet Plant
2,000sets/month cabinets and racks
Partners
Certifications
ROHS
ISO
9001
MSDS
CE
IP65
Contents
2
3
4
Sunshine Outdoor Cabinet Introduction
Reference Cases
Outdoor Cabinet Applications in Telecom Network
Company Introduction1
Brief Introduction
The Classification of communication outdoor cabinet -- Based on application mode
In general, the base station outdoor cabinet provides comm-unication base stationequipment with protective cabinet (BTS, BBU, RRU and so on.)
The fixed network outdoor cabinet including broad\narrow band AN(access network) out- door cabinet, provides access network equipment and wiring module with protective cabinet.
Base stat ion outdoor cabinet(BBU RRU)
Fixed network outdoor cabinet(FTTCab+xDSL access)
Base station outdoor cabinetcabinetFixed network outdoor cabinet
FTTx Outdoor Cabinet Solution
Outside ONU cabinet
Copper
C o p p e r cableCO
Street cabinet
Street cabinet
C r o s s connection Fibercopper
DropCabinet
Fiber
Fiber
Fiber
Copper
Fixed network outdoor cabinet configuration
Broad band access network configuration
Monitoring unit
-48Vpower systemDC distribution
DDF unit
ODF
MDF module
AC distribution
(DSLAM, ONU)
Battery
Wireless Station Outdoor Cabinet Configuration
(BTS/RRU/BBU)
temperature control unit(air-condition/ h e a t e x c h a n g e /TEC/fan)
Wireless station configuration
-48V power supply
Monitoring unit
AC/DC distribution/
anti-lightning
ODF unit/DDF unit
Battery
Contents
2
3
4
Outdoor Cabinet Applications in Telecom Network
Reference Cases
Sunshine Outdoor Cabinet Introduction
Company Introduction1
Technical Features
Waterproof, dustproof, theft proof, corrosion prevention, anti-lightning
Miniaturization,reduction in area
Highly integrated, unified management
Modular design, flexible configuration
Subdivision control, economic and energy saving
Quick assembly and easy expansion
5 proof
Economic energy-saving
Rapid Deployment
Easy expansion
Design Capability
The classification of communication outdoor cabinet – based on the way of
temperature control
The outdoor cabinet can be divided into three types according to the way of temperature control: Fan type outdoor cabinet , Heat exchanger type outdoor cabinet , Air-condition outdoor cabinet
The selection of the temperature control ways of outdoor cabinet depends on heat resistance performance of the equipment, the site environ-ment and climate.
Fan type outdoor cabinetHeat exchanger type outdoor cabinet
A i r - c o n d i t i o n e r outdoor cabinet
Outdoor cabinet thermal simulation design
Structural Design
The out door cabinet can be divided into two types according to the structural style;
integrated outdoor cabinet and assembled type outdoor cabinet
Site assembly outdoor cabinet (profile + sandwich structure)
Scattered parts delivery, site installation. Standard three-compartment cabinet only 2 people 2 to 4 hours to complete.
Only specially designed cabinet structure can be achieved (e.g: assembled mini computer room)
IP55 Design
Waterproof sealing tape
Waterproof louver outdoor cabinet
Multiple waterproof outdoor cabinet Roof, doors, feeder holes, opening blinds and other multiple structural waterproofing Outdoor cabinet overall protection (waterproof, dustproof) level reaches IP55
Waterproof feeder holeTilted rooftop without hydrops
Tilt angle of the top ≥2.5%
High Strength and Anti-Corrosion Design
Door stopper
High comprehensive mechanical strength,
strong anti-wind ability
uUnder normal working condition, the cabinet can withstand strong wind at a
speed of 45m/s
u The threshold of affordable 22 m/s wind load
To adapt to the outdoor high anti-corrosion requirements
u High quality galvanized sheet magnesium aluminum zinc plate spray
outdoor powder, or pre-coated color steel cabinet material
u External exposure surface treatment can afford a 500-hour anti salt spray corrosion,
which ensures a safe use
Lightning Protection and EMC Design
Lightning Protection Module
uPower supply protecting module configuration from class B lightning
uEquipment in cabin have good grounding protection and working protection
uAll active devices are connected to the equipotential card
Monitor Center
RRU
Smoke Water Door Infrared rayTemperatureHumidity Door Power Cooling
lightning protection monitoring Power supply
Battery
meter Box
ATS
Miniaturization and Integration
Outdoor cabinet
Reduce the floor area by more than 60%, high integration to facilitate unified management
Subdivision Temperature Control, Effective Energy Saving
Subdivision temperature control, precise air supply,
Save more than 40% energy
Battery
cabinet
Corollary
Equipment
cabinet
Master
device
cabinet
Battery cabinet; TEC or small precision air conditioner, with both refrigeration and heating mode
(The working temperature for the battery is required to control between 20℃ to 30℃)
Master device cabinet; Heat exchanger,Blue heating optional
(The working temperature for the Master device is be- tween -40℃~+55℃ )
Corollary equipment cabinet; nature thermal dissipation or direct ventilating.
(The working temperature for the Corollary equipment -20℃-50)
Subdivision Temperature Control, Energy Saving -Efficient
Temperature control
Equipment Power consumption
refrigerating capacity /heat exchange capacity
Heating capacity Equipment heat consumption
Comment
TEC200 TEC-air condition
300W 200W 200W;
Battery,
200W
DC-48V Power
EC300 Small precision-air
condition
200W 300W Plus heat 400W AC220V Power
HEX100 Heat exchanger
110W 100W/K Plus heat:1000W
(Optional, cabinet use incase below 0 ℃ )
1000W below △T≤15℃
(Cabinet Tinside-Toutside)
HEX190 210W 190W/K 2500W below
Model EC10 EC12 EC15 EC20
C o o l i n g Capacity(W)
1000 1200 1500 2000
O u t p u t Voltage(W)
520 890 910 1050
C u r r e n t Input
220-240VAC/~/50-60Hz
Heat (W) 1000 1000 1000 1000
Noisy dB(A) 63 63 63 63
W(mm) 430 430 430 500
H(mm) 1100 1100 1100 850
D(mm) 195 195 195 240
Refrigerating fluid
R134a
Temp Range -40℃~55℃
Weight(Kg) 38 40 42 45
Air Conditioning
Heat Exchanger
Model EX04 EX07 EX10 EX12
H / E capacity(W/K)
40 70 100 120
O u t p u t Voltage(W)
100 160 170 190
Current Input 36~57VDC
Heat (W) 1000 1000 1000 1000
Noisy dB(A) 63 63 63 63
W(mm) 350 400 450 430
H(mm) 650 950 1050 1100
D(mm) 140 145 150 195
Temp Range -40℃~55℃
Weight(Kg) 21 26 28 30
Contents
2
3
4
Outdoor Cabinet Applications in Telecom Network
Reference Cases
Company Introduction1
Sunshine Outdoor Cabinet Introduction
Mobily In Saudi Arabia
Double compartment: battery o n t h e l e f t s i d e w h i l e distribution unit and BTS are on the right side; front door opened; install on the ground
Air conditioner for b o t h compartments
A string of battery 2V/500AH
Dimension(H×W×D) : 2150mmX905mmX905mm
Typical MeNB Station
Typical extended fiber station)
Double compart-ment with front d o o r o p e n e d ; overhead install on the ground
Fans on the top Left compartment: RRU equipment
Right compartment: transmission equipm--ent, power supply and battery
Dimension(H×W×D) : 1600mmX1600mmX 650mm
Fixed Network Outdoor Cabinet
Project: Broadband reconstruction of telecom box in China
Solution:Air conditioner outdoor cabinet
Features:left side: air conditioner compartment, 1000W industrial air conditioner
Right side: equipment compartment with 19inchs mounting rack and integrated main equipment, power supply and cables and so on
1U
1U
2U
DSLAM
Broadband test equipment
Environmental
monitoring equipment
Headspace
The height of column is 1275m
m
10U
1U
2U
DSLAM cabling trap(selectable)
2U1U
2U1U AC module
Fiber splice tray
1U2U
1U
DC module
1U=44.45mm
Base Station outdoor Cabinet
Project: H/HEB telecom C network base station
Solution:Assembled outdoor cabinet
(Being able to assemble cabinet on site, rooftop and mountain)
Features:Standard outdoor cabinet solution
Battery compartment: TEC air conditioner;
Equipment compartment: heat exchanger
(small power consumption, energy-saving)
Ground outdoor cabinet
Ground Outdoor Cabinet
•Thank you!