Planungsunterlagen fr das Parkhaus Management System
Planning Documents
for the Car Park Management Systems
Planning ManualCar Park Management Systems- Planning Documents -ContentsPage
41Introduction
1.1About this Manual41.2Definition of used icons41.3Legal information41.4User instructions42Central Computer, Management Computer and Manual Cashier Station62.1General survey of devices62.2Arrangement of components73Entries, Exits and Passages83.1Control Devices83.1.1Terminals for Entry, Exit and Passage for the Side stripe and/or the Barcode System: PGL20/S; PGL25/S; PL20/S; PL25/S as well as PGL20/B; PGL25/B; PL20/B; PL25/B83.1.2Terminals for Entry, Exit and Passage for the ChipCoin( System: PGL20/C; PGL25/C; PL20/C; PL25/C123.1.3Terminals for Entry, Exit and Passage for the Side stripe System, Barcode System and ChipCoin( System: PGL30/S; PL30/S; PGL30/B; PL30/B as well as PGL30/C; PL30/C143.1.4Multi Control Unit (MKG)173.1.5Car Park Access Reader for barrier control PCX35213.1.6Contactless Card Reader for Access Control for long term parker263.2Addition for Entry, Exit and Passage Terminals: Dispensing tray as rain protection283.3Barriers293.3.1Safety293.3.2AS20 / AS2000293.3.3AS30333.3.4AS35353.3.5Barrier equipment and accessories373.4Prefabricated steel island for devices403.4.1Islands made of flat steel403.4.2Islands made of steel tube443.5Nudge bar453.5.1For control devices PGL20 / PL20453.5.2For barriers AS20, AS2000473.6Loops / Cable ducts483.6.1Laying of loops483.6.2Laying of cable ducts513.7Situations at the Entry, the Exit and the Passage523.7.1Plan for an Entry Lane523.7.2Plan for an Exit Lane523.7.3Plan for a bi-directional lane533.7.4Plan for a double-sided lane533.8Manual Cashiering at the Exit544Automatic Pay Stations564.1PKA2x with banknote processing and optional with non-cash payment564.1.1Mounting niche for PKA2x614.1.2Illuminated top for PKA2x614.1.3Roofing for Automatic Pay Station PKA2x624.2Automatic Pay Station for only non-cash payment664.2.1PAY20/S665Ticket / Card Reader for Door Control685.1PTL20685.2PTL35695.3PTL36726Complements746.1Steel Mast for Signals (for example mast for Multi Control Unit)746.2Holder for alternation sign for wall mounting796.3Signal Indication806.4Displays for S&B Guidance Systems827Mounting of the Device918Wiring Diagram928.1Legend938.2Safety Instructions949Information about Power Supply and Overvoltage Protection959.1General Information959.2Information about Screening959.2.1LON networks959.2.2RS485 networks959.2.3Ethernet networks959.2.4Power Supply PTL3695List of illustrations97
1 Introduction
1.1 About this Manual
This Planning Manual contains technical information about major components of the Scheidt & Bachmann Car Park Management Systems, as well as information about the installation and the connection of these components. The shown installation variants can be modified and show a basic representation only. Final planning and installation is made project-related complying with the minimum dimensions.
1.2 Definition of used icons
The following icons will be used in this Planning Manual:Power supply / Power consumption
Connections
Weight
Incidentals
Conformity and Certification
Mounting / Installation
Ambience conditions
1.3 Legal information
The "Planning Manual" and all its parts is protected by copyright. Scheidt & Bachmann GmbH reserve all rights concerning the work. Each utilization, which is not expressly approved from the copyright law, requires the previous approval of Scheidt & Bachmann GmbH. This applies in particular to duplication, revision, translation, microfilming as well as storing and processing in electronic systems.
Since references and facts are subject to technological changes, no responsibility can be taken for the given information. Changes of technical details regarding data and illustrations in the Planning Manual are reserved. Always pay attention to the update index.
1.4 User instructions
For detailed information please contact the sales and marketing department of Scheidt & Bachmann GmbH and their subsidiaries and authorized partners. The contact persons for your country and region can be found in the Internet on our homepage: www.scheidt-bachmann.com.
This Planning Manual is not intended to provide instructions through self-study. Concerning the users of this Planning Manual, technical understanding and knowledge is taken for granted as well as previous experience regarding stationary traffic and parking facilities. The execution of work may only take place after briefing and/or training by specialized personnel of Scheidt & Bachmann GmbH or their subsidiaries and authorized partners.
Concerning special solutions, this manual does not claim to be complete.
2 Central Computer, Management Computer and Manual Cashier Station
2.1 General survey of devicesCRT MonitorLCD MonitorCustomer display
ComputerPrinterReceipt printer
Read / Write Unit SL20Barcode scannerRead / Write Unit SL20/C
Functional keyboardPC keyboardMouse and Pad
UPS (Uninterruptible Power Supply)
2.2 Arrangement of components
ZR20ZAR20LR20LAR20POS20/SPOS20/BPOS20/CPOS25/SPOS25/BPOS25/CPOS20-R/SPOS20-R/BPOS20-R/C
CRT Monitor
LCD Monitor
Customer display----
Computer
Printer------
Receipt Printer----
SL20-------
Barcode scanner----------
SL20/C----------
POS keyboard----
PC keyboard
Mouse and Pad---
UPS
Legend:
=Standard
=Optional available
-=not available / not needed
Note:
For thermal reasons, at least 10 cm behind and 10 cm above the PC must be left free for ventilation.
All dimensions are the actual dimensions of the devices. When planning, reserves must be planned for voltage and control line connectors (approx. 10 cm).
For the connection of peripheral devices to the PC, appropriate cabling possibilities must be planned, taking into account that the maximally permissible standard lengths are not exceeded.
Dependent on the execution, the dimensions of the devices may vary and may be changed by the respective manufacturer.
3 Entries, Exits and Passages
3.1 Control Devices
3.1.1 Terminals for Entry, Exit and Passage for the Side stripe and/or the Barcode System: PGL20/S; PGL25/S; PL20/S; PL25/S as well as PGL20/B; PGL25/B; PL20/B; PL25/B
Entry terminal as dispenser for short term parker tickets for Side stripe and Barcode tickets and card reader for long term parker cards.
PGL20/S, PGL25/S: Entry terminal for the Side stripe System
PGL20/B, PGL25/B: Entry terminal for the Barcode System
Exit and Passage terminal as ticket / card reader for short term parker and long term parker for Side stripe and Barcode tickets.
PL20/S, PL25/S: Exit and passage terminal for the Side stripe System
PL20/B, PL25/B: Exit and passage terminal for the Barcode System
Technical Data
230 V/50 Hz or 115 V/60 Hz
PGL20/S, PGL20/B: 300 VA
PGL25/S, PGL25/B: 200 VA
PL20/S, PL20/B: 250 VA
PL25/S, PL25/B: 160 VA
Additional 700VA used for heating / ventilation
Power supply
Network
Intercom Serial interface RS232 Binary Inputs (electrically isolated)
Binary Outputs (electrically isolated)
60 kg net weight
UL, CUL, CE Ticket specification for Side stripe tickets: S&B 04 26743 Ticket specification for Barcode tickets: S&B 04 26670
The machine will be mounted by Scheidt & Bachmann on a base that must be provided by the customer according to our specification.
Concrete foundation B25 must be suitable for winter condition.
Vertical installation to be ensured.
Drilling template: S&B 04 17490
For indoor and outdoor installation
Temperature range: - 20 C+ 50 C
Humidity: 095 % (not condensing)
PGL20/S; PGL25/S; PL20/S; PL25/S as well as PGL20/B; PGL25/B; PL20/B; PL25/B
Size / foundation plan (dimensions in mm):
86 86881 (c) PGL20S_B PL20S_B_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
PGL20/S; PGL25/S; PL20/S; PL25/S as well as PGL20/B; PGL25/B; PL20/B; PL25/BHGV/Truck extension: Size / foundation plan (dimensions in mm):
86 60095 (-) LKW-Bus Adapter fr PGL20_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
PGL20/S; PGL25/S; PL20/S; PL25/S as well as PGL20/B; PGL25/B; PL20/B; PL25/BPrefabricated foundation frame (galvanized)
86 86993 (-) Fundamentrahmen PGL20
3.1.2 Terminals for Entry, Exit and Passage for the ChipCoin( System: PGL20/C; PGL25/C; PL20/C; PL25/C
Entry terminal as dispenser for short term parker ChipCoins( and for checking of long term parker cards based on transponder technology.Designation: PGL20/C; PGL25/C
Exit and Passage terminal for checking of short term parker ChipCoins( and long term parker cards based on transponder technology.Designation: PL20/C; PL25/C
Technical Data
230 V/50 Hz or 115 V/60 Hz
PGL20/C, PL20/C: 200 VA
PGL25/C, PL25/C: 150 VA
Additional 700VA used for heating / ventilation
Power supply
Network
Intercom Serial interface RS232
Binary Inputs (electrically isolated)
Binary Outputs (electrically isolated)
85 kg net weight
For indoor and outdoor installation
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
ChipCoin( specification: S&B 04 18399
UL, CUL, CE
The machine will be mounted by Scheidt & Bachmann on a base that must be set up by the customer according to our specifications.
Concrete foundation B25 must be suitable for winter condition.
Vertical installation to be ensured
Drilling template: S&B 04 17781
PGL20/C; PGL25/C; PL20/C; PL25/CSize (dimensions in mm):
86 85257 (c) PGL_PL20C_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
3.1.3 Terminals for Entry, Exit and Passage for the Side stripe System, Barcode System and ChipCoin( System: PGL30/S; PL30/S; PGL30/B; PL30/B as well as PGL30/C; PL30/C
Entry terminal as dispenser for short term parker tickets and / or ChipCoins( and for checking of long term parker cards based on Side stripe, Barcode and ChipCoin( technology.
PGL30/S: Entry terminal for the Side stripe system
PGL30/B: Entry terminal for the Barcode system
PGL30/C: Entry terminal for the ChipCoin( system
Exit and Passage Terminal for checking of short term parker tickets and long term parker tickets or transponder cards based on the Side stripe, Barcode and ChipCoin( technology.
PL30/S: Exit and passage terminal for the Side stripe system
PL30/B: Exit and passage terminal for the Barcode system
PL30/C: Exit and passage terminal for the ChipCoin( system
Technical Data
230 V/50 Hz or 115 V/60 Hz
PGL30/S, PGL30/B: 300 VA
PGL30/C: 200 VA
PL30/S, PL30/B: 250 VA
PL30/C: 200 VA
additional 700VA used for heating / ventilation
Power supply
Network
Intercom Serial interfaces RS232
Binary Inputs (electrically isolated)
Binary Outputs (electrically isolated)
PGL30/S: 63 kg PGL30/B: 60 kg PGL30/C: 62 kg
For indoor and outdoor installation
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
Ticket specification for Side stripe tickets: S&B 04 26743 Ticket specification for Barcode tickets: S&B 04 26670 ChipCoin( specification:
S&B 04 18399
The machine will be mounted by Scheidt & Bachmann on a base that must be set up by the customer according to our specifications.
Concrete foundation B25 must be suitable for winter condition.
Vertical installation to be ensured.
PGL30/S; PL30/S; PGL30/B; PL30/B as well as PGL30/C; PL30/C
Size (dimensions in mm):
86 61805 (-) PGL_PL30 Ansicht_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
PGL30/S; PL30/S; PGL30/B; PL30/B as well as PGL30/C; PL30/C
Foundation plan (dimensions in mm)
86 61805 (-) PGL_PL30 Fundamentplan_e
3.1.4 Multi Control Unit (MKG)
Size (dimensions in mm):
86 68468 (c) MKG_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
Multi Control Unit (MKG)
Foundation plan (dimensions in mm)
86 68470 (a) MKG-Fundamentplan_e
Wall mounting (dimensions in mm)
86 79552 (a) MKG Wandmontage_e
Multi Control Unit (MKG)
For cars and lorries (dimensions in mm)
86 86501 (-) MKG-LKW_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
Multi Control Unit (MKG)
Foundation plan for double MKG (Cars and lorries) dimensions in mm
86 86501_2 (-) Fundamentplan MKG-LKW_e
3.1.5 Car Park Access Reader for barrier control PCX35
Access control device for barrier control at entries, exits and passages.
The following media can be processed:
Side stripe tickets and cards
Barcode tickets and cards
ChipCoins( and Transponder cards (S&B)
Proximity cards (third party)
Additional hardware S2000 required which can be located in the barrier.
Mixtures of the media mentioned above corresponding with the table below:
Basic functionOptionsWith
displayWithout
display
BarcodeTransponderSide stripe
(MKV/Motor)Side stripe
(insert card)ProximityCode (1)
BarcodeXO--O-OO
TransponderOXOO-OOO
Side stripe (MKV/Motor)-OXXO-OO
Side stripe (insert card)-OXXO-OO
ProximityO-OOX-OO
Code-O---XO-
O = Combination possible within one device
- = Combination not possible within one device
(1) = Devices for code-input are available with display only.
S&B tickets (season parker, short-term parker, value cards, etc.) can only (!) be processed with the MKV Terminal (motor reader with write function) and not with an insert card reader.
Technical Data PCX35
230 V/50 Hz or 115 V/60 Hz
approx. 150 VA
Additional 30VA used for heating / ventilation
Power supply
Dialogue (RS485)
Intercom
approx. 5 kg net weight
For indoor and outdoor installation.
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
Ticket specification for Side stripe tickets: S&B 04 26743 Ticket specification for Barcode tickets: S&B 04 26670 ChipCoin(-Specification:
S&B 04 18399
CE
Stand or wall mounting
PCX35
Size (dimensions in mm):
86 60810 (b) PCX35 Ansicht
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
PCX35
Foundation plan (dimensions in mm)
86 60810 (b) PCX35 Fundamentplan_e
PCX35 insert card
Size / Foundation plan (dimensions in mm)
PCX Steckleser (-)
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
3.1.6 Contactless Card Reader for Access Control for long term parker
Contactless card reader for HID cards as long term parker cards for access control at entries, exits or passages
Technical Data
12 or 24 VDC
approx. 25 W
Power supply
Approx. 1.,4 kg net weight(without stand)
For indoor and outdoor installation
Temperature range: -30 C+65 C
Humidity: 095 % (not condensing)
HID cards
Typical maximum* range of reading:
ProxCard(-II card: max. 73 cm
ISOProx(-II card: max. 50 cm
ProxKey(-II key chain: max. 43 cm
ProxCard(-Plus card: max. 25 cm
SmartProx( card: max. 43 cm
ProxPass(: max. 2,40 m
*According to local installation.
UL; CE, US-DTI (MPT 1337)
Stand mounting
Additional technical data:
Frequency: 125 kHz
Example for contactless card reader: MaxiProx( reader
Size (dimensions in mm)
MaxiProx
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
3.2 Addition for Entry, Exit and Passage Terminals: Dispensing tray as rain protection
04 24597 (a) Regenschute PGL_PL_e
Example: Dispensing tray as rain protection at the entry terminal for the Side stripe System
Regenschute an PGL20_S_e
3.3 Barriers
3.3.1 Safety
The barrier is exclusively suitable for traffic with average passenger cars. The barrier is not suitable for traffic with pedestrians, cyclists and motorcyclists. Depending on the type of traffic and application, the operation of barriers may be subject to various rules for the prevention of accidents and DIN standards. Therefore, the manufacturer strongly advises to apply suitable instructions, notes, signs and structural measures in order to keep the danger zone of the barrier free from traffic with pedestrians, cyclists and motorcyclists.
3.3.2 AS20 / AS2000
Barrier as a gate for parking areas. The barrier is intended for the use as "Class II barrier for the commercial (( five-family house / apartment, hotels, garages, shops) and general (public entry / exit) access control for vehicles".
Special functions: Barrier reverses when touching an obstacle; Automatic opening of the barrier in the case of power failure as an option.
Not suitable for applications with increased safety requirements, i.e. protection against crossing danger (railway), breakthrough barricade (ferry access road, military safety area), or similar!
Technical Data
230 V/50 Hz or 115 V/60 Hz
approx. 200 VA
Power supply via entry and exit control devices (PGL / PL) or via separate fuse-protected supply line
Control and acknowledgement signals
Approx. 60 kg net weight without barrier arm
For indoor and outdoor installation
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
CE
AS2000: CE, UL, CUL
The machine will be mounted by Scheidt & Bachmann on a base that must be set up by the customer according to our specifications.
Concrete foundation B 25 must be suitable for winter condition.
Vertical installation to be ensured
Additional technical data:
Length or barrier arms (standard):AS20:2.5 m; 3.0 m; 3.5 m
AS2000:2.5 m; 3.0 m; 3.5 m; (5.4 m with extras)
Time for barrier opening:
AS20:
approx. 1.5 s for a 90-degree movement
AS2000:after 1.2 s approx. 80 degrees of final position and after 2.3 s 90 degrees.
Time for barrier closing:
AS20:
approx. 1.5 s for a 90-degree movement
AS2000:after 1.2 s approx. 25 degrees of final position and after 2.4 s 0 degrees.
In case of a closure with a magnetic impact post, slower closing can be set by means of a DIP switch!
AS20 / AS2000
Size / foundation plan (dimensions in mm):
86 85055 (f) Schranke AS20_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
AS20
Prefabricated foundation frame (galvanized) (dimensions in mm)
86 86994 (-) Fundamentrahmen AS20_e
3.3.3 AS30
Barrier as a gate for parking areas.
Not suitable for applications with increased safety requirements, i.e. protection against crossing danger (railway), breakthrough barricade (ferry access road, military safety area), or similar!
Technical Data
230 V/50 Hz or 115 V/60 Hz
approx. 200 VA
Power supply via entry and exit control devices (PGL / PL)
Control and acknowledgement signals
Approx. 60 kg net weight without barrier arm
For indoor and outdoor installation.
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
CE
AS2000: CE, UL, CUL
The machine will be mounted by Scheidt & Bachmann on a base that must be set up by the customer according to our specifications. Concrete foundation B25 must be suitable for winter condition.
Vertical installation to be ensured
Additional technical data:
Length of barrier arms (standard): 2.5 m; 3.0 m; 3.5 mTime for barrier opening:after 1.2 s approx. 80 degrees of final position and after
2.3 s 90 degrees.
Time for barrier closing:after 1.2 s approx. 25 degrees of final position and after
2.4 s 0 degrees.
In case of a closure with a magnetic impact post, slower closing can be set by means of a DIP switch!
AS30
Size / foundation plan [dimensions in mm (ft)]:
86 61806 (a) AS30_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
3.3.4 AS35
Barrier as a gate for parking areas.
Not suitable for applications with increased safety requirements, i.e. protection against crossing danger (railway), breakthrough barricade (ferry access road, military safety area), or similar!
Technical Data
230 V/50 Hz or 115 V/60 Hz
approx. 200 VA
Power supply via entry and exit control devices (PGL / PL)
Control and acknowledgement signals
Approx. 60 kg net weight without barrier arm
CE
AS2000: CE, UL, CUL
For indoor and outdoor installation.
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
The machine will be mounted by Scheidt & Bachmann on a base that must be set up by the customer according to our specifications.
Concrete foundation B25 must be suitable for winter condition.
Vertical installation to be ensured.
Additional technical data:
Length for barrier arms (standard): 2.5 m; 3.0 m
Time for barrier opening:after 1.2 s approx. 80 degrees of final position and after
2.3 s 90 degrees.
Time for barrier closing:after 1.2 s approx. 25 degrees of final position and after
2.4 s 0 degrees.
In case of a closure with a magnetic impact post, slower closing can be set by means of a DIP switch!
AS35
Size / foundation plan (dimensions in mm):
86 61794 (-) AS35_e
When the device is mounted on an island, the stated dimensions referred to the lane are possibly increased by the height of the curb or island (approx. 130 170 mm).
3.3.5 Barrier equipment and accessories
The following barrier arm profiles are possible:
Round profileOctagonal profile
(with rubberised lower edge)Square
profile
(with rubberised lower edge)
AS20
AS2000
AS30
AS35--
Articulated arm-
possible -not possible
Barrier arm as articulated barrier arm (possible with AS20; AS2000; AS30)
Dimensions in mm
Schrankenbaum
Always keep the minimum distance between the articulated barrier arm and the ceiling (country-specific) when the barrier is open.
Formed part for barrier arm profiles (dimensions in mm)
For reasons of safety, a formed rubber (polyurethane) part can be attached on the freely swinging end of the barrier arm as well as a piece of rubber profile. Possible injury can thus not be completely excluded, the degree of injury, however, can be decreased.
86 95305 (-) Formstck Schranke
86 86984 (-) Fertigungshinweis
Length of barrier arms up to 5.40 m (only possible with AS2000)
Barrier length: 6.00 m
Dimensions in mm
86 61022 (-) AS2000 5m_e
From an arm length of 3.40 m (corresponds to a barrier length of 4.00 m), counterweights are used.
The following arm lengths are available for the AS2000 with counterweights:
Length barrier arm (in m)Corresponding barrier length (in m)
3.404.00
3.904.50
4.405.00
5.406.00
3.4 Prefabricated steel island for devices
3.4.1 Islands made of flat steel
Variant 1: Double-sided island entry/exit, centred mast connectionSize (dimensions in mm):
86 61584_1 (e) Flachstahlinsel_e
Note: All mounting screws are screwed in when the island is manufactured, and the screw thread is covered with an insulating plastic tube (M12 x 50 or M16 x 50).
Variant 2: Island for a double-sided lane for entry and exit
86 61584_2 (e) Flachstahlinsel_e
Note: All mounting screws are screwed in when the island is manufactured, and the screw thread is covered with an insulating plastic tube (M12 x 50 or M16 x 50).
Variant 3: Island for Entry and/or Exit
86 61584_3 (e) Flachstahlinsel_e
Note: All mounting screws are screwed in when the island is manufactured, and the screw thread is covered with an insulating plastic tube (M12 x 50 or M16 x 50).
Variant 4: Double-sided island for Entry / Exit with truck extension
86 61584_4 (e) Flachstahlinsel_e
Note: All mounting screws are screwed in when the island is manufactured, and the screw thread is covered with an insulating plastic tube (M12 x 50 or M16 x 50).
3.4.2 Islands made of steel tube
Size (dimensions in mm):
86 60428 (a) Rundrohr-Insel_e
3.5 Nudge bar
3.5.1 For control devices PGL20 / PL20
Variant 1 Size (dimensions in mm):
86 60818 (-) Rammschutzbgel
Nudge bar for control devices PGL20 / PL20
Variant 2 Size (dimensions in mm):
86 60819 (-) Rammschutzbgel_2 PGL_PL
3.5.2 For barriers AS20, AS2000
Size (dimensions in mm):
86 60820 (-) Rammschutzbgel_AS
3.6 Loops / Cable ducts
3.6.1 Laying of loopsProcedure
The most common way of laying loops is by milling slots in the asphalt or concrete, into which a 1.5 mm2 plastic-coated copper conductor is laid in several turns. The slot is approx. 5 mm wide and approx. 30 mm deep. The connecting groove between the loop and the detector connection is milled a bit wider so that the twisted line will fit in. The loop is grouted in with cold grouting compound.
It is not recommended to lay the loops before the concrete or asphalt is finished. However, if this should be necessary, prefabricated loops with a protective coating should be used, which are laid into the prefabricated geometrical form in order to be covered with concrete or asphalt then.
If concrete slabs are used as road topping, expansion joints are often required. If the loop wire crosses an expansion joint, an extra turn must be made in order to avoid that the loop is cut when the concrete slabs are moving. Never lay loops and loop supply lines directly into the expansion joints.
When loops are laid under the pavement, never lay the loop wire directly into the sand. In such a case always use prefabricated loops, which must be laid onto a firm subsoil so that it cannot break. When loops are laid under the pavement it must also be noted that rainwater may seep into the layer of sand so that the inductivity of the loop may change. The damp soil and/or sand layer then works in particular in connection with thawing salt like (relatively badly conducting) metal, i.e. the loop is like vaporized. In addition, the prefabricated loops may not be laid to deep into the sand layer, since otherwise the distance between the upper edge of the pavement and the loop will be too large causing a worse sensitivity.
The loop supply line should be laid as far away as possible from mains supply lines (min. 20 cm). In no case, loop supply lines and mains supply lines may be laid in the same duct or conduit.
Loop supply lines should also be laid as firm as possible so that they cannot move. This also applies when laid within the switch cabinet. Even in this case, the line must be twisted. If a connection between the loop and the loop supply line must be made in the proximity of the loop or even in the ground or next to the ground, it must be ensured that the connection is waterproof and protected against damage.
Basic rules when laying loops
The loop size must be adjusted to the expected vehicle size.
Loops may not be laid in manoeuvre areas.
Loops may not be laid in the swivelling range of metal gates.
Loops must be laid at least 5 cm higher than steel reinforcement or metal vapour barriers (metal foils) or the reinforcement must be made outside the loop area.
With rectangular loops the corners are slanted in order to avoid a too high mechanical load on the loop wire at the corners, which could lead to parting of the cable or defects in insulation.
Manhole covers, sewage piping, hydrants, etc., which are located in the sphere of influence of the loop, must have a minimum distance of approx. 0.5 m to the loop.
The loop and the supply line must be laid very carefully.
Recommended number of turns with rectangular loops
Loop circumferenceNumber of turns
< 3 m6
3 4 m5
4 6 m4
6 12 m3
> 12 m2
Size (dimensions in mm)
86 68017 (f) Schleifenverlegung_eBarrier
Device for Entry, Exit and / or Passage
Laying of loops
86 67748 (a) Schleifen_e3.6.2 Laying of cable ducts
86 71667 (a) Kabelschutzrohr Induktionsschleifen_e3.7 Situations at the Entry, the Exit and the Passage
3.7.1 Plan for an Entry Lane
Dimensions in m
86 85046 (d) Lageplan EF_e
3.7.2 Plan for an Exit Lane
Dimensions in m
86 85046 (d) Lageplan AF_e
3.7.3 Plan for a bi-directional lane
Dimensions in m
01 082801 Wechselspur_e
The final location of the devices must be determined on site, in coordination with the supervision of works, possibly by means of driving tests. In the range of the induction loops "I", the reinforcement must be covered by a layer of 6 cm min.
3.7.4 Plan for a double-sided lane
Dimensions in m
86 85046 (d) Lageplan PH Standard_e
3.8 Manual Cashiering at the Exit
In this case, the parking fee to be paid is paid with an employee of the car park at the exit with cash or with credit card. Without leaving the car, the customer inserts the parking ticket into the ticket reader. The ticket insert is located at the outside of the cashier booth. The cashier collects the parking fee. Only after payment was made, an opening signal is transmitted to the barrier and the customer can pass the open barrier.
Example of the basic arrangement of the devices (dimensions in mm)
86 90464 (b) Ausfahrtskassierung_e
Example of a detail of the customer transaction panel at the cashier boothNote: When planning the cashier booth, the provisions of the country-specific workplace regulations concerning, among others,
dimensions
air conditioning
solar radiation
illumination
protective measures against the intrusion of exhaust fumes (e.g. overpressure)
and others
must be applied.
86 91662 (-) Ausfahrtskassierung_Detail
Customer transaction panel exit cashiering
Booth (Dimensions are specific to the project)
Card reader (SL20)
4 Automatic Pay Stations
4.1 PKA2x with banknote processing and optional with non-cash payment
Automatic Pay Station for payment of parking fees. The fee is calculated in accordance with the stored tariff data and displayed after the parking ticket/card or the ChipCoins( has been inserted. Payment can be effected with various means of payment.
Designation:
PKA20/S, PKA25/S, PKA26/S: Side stripe system
PKA20/B, PKA25/B, PKA26/B: Barcode system
PKA20/C, PKA25/C, PKA26/C: ChipCoin( system
Technical Data
230 V/50 Hz or 115 V/60 Hz
270 VA
Banknote processing: 7 VA (quiescent current) 60 VA (operating current)
Additional 700 VA for heating / ventilation.
Illuminated top: 18 VA
Power supply
Network
Intercom
220 kg net weight w/o banknote processing and pedestal
For indoor or protected outdoor installation.
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
Ticket specification for Side stripe tickets: S&B 04 26743 Ticket specification for Barcode tickets: S&B 04 26670
UL, CUL, CE
Mounting on a steel or concrete pedestal or on a pedestal referring the specification.
PKA2x
Size (dimensions in mm):
86 60789 (a) PKA Masszeichnung_e
PKA2x
Foundation plan for concrete pedestal [Dimensions in cm (ft)]
86 65447 (d) Fundamentplan PKA_e
PKA2x
Steel pedestal
Size and fixing [dimensions in mm (ft)]
86 60789 (a) Befestigung Stahlsockel_e
PKA2x
Prefabricated foundation frame (galvanized) (dimensions in mm)
86 86995 (-) Fundamentrahmen PKA2x_e
4.1.1 Mounting niche for PKA2x
Dimensions in mm
Einbaunische PKA20_e4.1.2 Illuminated top for PKA2x
As an option, the Series PKA2x automatic pay station can be provided with an illuminated top. In this case, attention must be paid to the resulting new total height of the automatic pay station.Size (dimensions in mm):
Beleuchtungsaufsatz_e4.1.3 Roofing for Automatic Pay Station PKA2x
Various roofings are available for the outdoor installation of automatic pay stations. These roofings are not only a weather protection for the automatic pay stations but also for the customers who have to pay the parking fees at the automatic pay station.
Variant 1:
Roofing for an automatic pay station: Dimensions in mm (ft)
86 60218_1 (a) berdachung_eRoofing for PKA2x
Foundation plan [dimensions in mm (ft)]
86 60218_2 (a) berdachung_eRoofing for PKA2x
Variant 2:
Roofing for two automatic pay stations: Dimensions [in mm (ft)]
86 61757 (-) Kassenhausunterstand_eThe foundation (structural concrete foundation B25) must be made in accordance with the manufacturer's instructions. Frost resisting execution must be ensured.Roofing for PKA2x
Variant 3:
Roofing for an automatic pay station: Dimensions [in mm (ft)]
PKA Dach_e
4.2 Automatic Pay Station for only non-cash payment
4.2.1 PAY20/S
Automatic Pay Station for non-cash payment of parking fees based on Side stripe tickets with credit cards
Technical Data
230 V / 50 Hz or 115 V / 60 Hz
approx. 790 VA
100 VA additional for heating / ventilation
Power supply
Network
Intercom
Approx. 80 kg net weight
For indoor or protected outdoor installation
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
Thermal receipt paper, Article No: S&B 50 82010
Reel diameter: 90 mm; Reel width: 58 mm
UL; CUL; CE
Wall mounting: with a recommended ticket insert height of 1400 mm
Mounting on steel pedestal
PAY20/S
Size [dimensions in mm (ft)]:
PAY20_e
Size pedestal (dimensions in mm):
04 26140 (a) PAY20-Sockel
5 Ticket / Card Reader for Door Control
5.1 PTL20
On-line door reader for checking the validity of short-term parking tickets and long-term parking tickets or ChipCoins( and transponder cards. A valid ticket /card / ChipCoin( generates an open signal for a normal door or a sliding door.
PTL20/B: Door reader for the Barcode system
PTL20/S: Door reader for the Side stripe system
PTL20/C: Door reader for the ChipCoin( system
Technical Data
230 V/50 Hz or 115 V/60 Hz
approx. 250 VA
30VA additional for heating / ventilation
Power supply
Network
Intercom
18 kg net weight For indoor or outdoor installation
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
UL, CUL, CE
For wall and stand mounting
The housing of the PTL20 is corresponding with the Multi Control Unit (MKG).
For sizes and illustrations see page 17.
5.2 PTL35
Access control device for normal door and sliding door controls.
The following media can be processed:
Side stripe tickets and cards
Barcode tickets and cards
ChipCoins( and transponder cards (S&B)
Proximity cards (third party)
Mixtures of the media mentioned above
Survey
The door readers are named by means of the following abbreviations so that the specific features can be seen from the name.
PTL35-D= with display
L
= On-line
T
= with S&B transponder reader
P= with Proximity card reader (various products)
Code= with code keyboard
Key= with key-operated switch
/B= with barcode reader
C= with reader for ChipCoin( and S&B transponder
cards
S= with slot reader
Technical Data
24 V DC (to be provided by the customer, power upon can be delivered upon request)
max. 5 VA
30VA additional for heating / ventilation
Power supply
Network (only PTL35-L/B and PTL35-LD/B)
Intercom Potential-free contact (optionally as break or make contact)
5 kg net weight For indoor and outdoor installation
Temperature range: -20 C+50 C
Humidity: 095 % (not condensing)
UL, CUL, CE
Wall mounting: with a recommend height of the ticket dispensing tray or the ChipCoin( antenna of 1200 mm
Stand mounting: on optional pedestal made of rectangular tube
PTL35
Size / Foundation plan (dimensions in mm):
86 60802 (a) PTL35_e
PTL35
Wall mounting (dimensions in mm)
PTL35 Wandbefestigung_e
Mounting holes:
4 x ( 8 drilling (min. drilled hole depth 55 mm)
5.3 PTL36
Access control device for Side stripe tickets and / or ChipCoins( and Transponder cards for normal door and sliding door controls.
PTL36/S: for the Side stripe system
PTL36/C: for the ChipCoin( system
Technical Data
8-12 V AC or DC (to be provided by the customer, transformer can be delivered upon request)
approx. 2 VA
Power supply
Network (only PTL36-L/S and PTL36-L/C)
Potential-free contact (as make contact)
0.7 kg net weight Only indoor installation!
UL, CUL, CE
Wall mounting: at a recommended height of 1200 mm
PTL36
Size (dimensions in mm):
86 60935 (-) PTL36 Ansicht
( EN screw fitting
Wall mounting (dimensions in mm)
86 60935 (-) Wandmontage_e
6 Complements
6.1 Steel Mast for Signals (for example mast for Multi Control Unit)
Size (dimensions in mm):
86 60069 (-) Mast_e
Signal mast
Prefabricated foundation frame for signal mast (galvanized) (dimensions in mm)
86 60015 (-) Fundamentrahmen fr Signalmast_e
Signal mast
Frame foundation cage (dimensions in mm)
86 61282 (-) Rahmen Fundamentkorb_e
86 86944 (-) Blech Fundamentkorb
Steel mast for Signs
Size [dimensions in mm (ft)]
86 62940 (c) Transparentmast_e
Steel mast for Signs
Foundation plan [dimensions in mm (ft)]
86 65017 (e) Stahlmast-Fundament_e
6.2 Holder for alternation sign for wall mounting
Dimensions (in mm):
86 79185 (a) Wechseltransparent_Wandmontage_e
6.3 Signal Indication
Signal indication with 1 light Dimensions [in mm (ft)]:
Signal_1
Signal indication with 2 lights Dimensions [in mm (ft)]:
Signal_2_eSignal indication with 3 lights Dimensions (in mm):
Signal_3
Laid-in templates for signal indication (directional arrows according to StVO traffic regulations)
Einlegeschablonen
6.4 Displays for S&B Guidance Systems
Parking guidance system displays / interior mounting
( LED Matrix displays
Application:
Interior, without direct solar radiation
Device type:
Complete device, maintenance-free, ready for connection,
one-side display
Symbol height:
Max. 120 mm
Reading distance:
up to 40 m
Symbol colour:
red, yellow, green
Device mounting:Prepared for wall mounting, ceiling mounting and mast mounting, individually adjustable angle of inclination. Wall and ceiling fixtures included in the delivery!
Operating temperature:-20 +50 C
Air humidity:10 90 % (not condensing)
Supply voltage:20 40 V DC
Power consumption:max. 5 W (with full illumination level, colour yellow)
Approval:- CE mark
- Electrical safety acc. to EN 60950
- Radio interference acc. to EN 50081-1 (residential area)
- Jamming resistance acc. to EN 50082-2 (industrial area)
Variants
Resolution
in Pixel
(H x B)For the
display of:LED display surface
in mm
(H x D)Housing dimensions
in mm
(H x W x D)
IM1
16 x 16 1 special
symbol120 x 120 200x200x45
IM2
16 x 32
3-digit
remaining lots120 x 240
200x322x45
IM3
16 x 48
Combination120 x 360
200x444x45
IM4
16 x 64
Combination120 x 480
200x566x45
Examples of special symbols (16 x 16 Pixel)
Parking guidance system displays / exterior mounting (selection)( Small information sign
Kleines Hinweistransparent_e
Caution:
Customer-specific realization of the inscription (texts, symbols, etc.) and of the colour!
- Mounting: - Mast mounting (optionally right or left) or
- Rear-side mounting or
- Mounting suspended from the ceiling
( Small information sign with alternating information
86 86372 (b) Kl. Wechseltransparent_e
Caution:
Customer-specific realization of the inscription (texts, symbols, etc.) and of the colour!
Execution with 2 positions: Full / Open:
- Alternating texts:Full red background, white letters
Open green background, white letters
- Electrical connections 230 V for 2 positions:
Protective conductor PE, neutral conductor N; L1 illumination; L2 Open; L3 Full
- Mounting: - Mast mounting (optionally right or left) or
- Rear-side mounting or
- Mounting suspended from the ceiling
( Information sign P-sign
Hinweistransparent_eCaution:Colour not corresponding with the original!
Customer-specific realization of the inscription (texts, symbols, etc.)!
( Information sign P-sign with alternating text
Transparent_eCaution:Colour not corresponding with the original!
Customer-specific realization of the inscription (texts, symbols, etc.)!
Notes:
Standard execution:
2 positions Full / Open
- Alternating texts:Full red background, white letters
Open green background, white letters
- Electrical connections 230 V for 2 positions:
Protective conductor PE, neutral conductor N; L1 illumination; L2 Open; L3 Full
- Colours: - Background: blue
- Light edges, arrow, P-symbol and (if applicable) writing: white
- Window: clear
Optional execution:
3 positions Full / Open / Closed
- Alternating text:Full red background, white letters
Open green background, white letters
Closed red background, white letters
- Electrical connections 230 V for 3 positions:
Protective conductor PE, neutral conductor N; L1 illumination; L2 Open; L3 Full;
L4 Closed
- Colours: - Background: blue
- Light edges, arrow, P-symbol and (if applicable) writing: white
- Window: clear
( P-sign with LED display
LED-Transparent_e
Caution:Colour not corresponding with the original!
Customer-specific realization of the inscription (texts, symbols, etc.)!
- Electrical connections 230 V:
Protective conductor PE, neutral conductor N; L1 illumination; L2 LED display
- Colours: - Background: blue
- Light edges, arrow, P-symbol and (if applicable) writing: white
- Window: clear
- Text colours: Figures: yellow
Open: yellow
Full: red
Closed: red
Description of the LED display
Application:
Exterior installation, well readable even with direct sun exposure
Device type:
Complete device, ready for connection, one-side display
Symbol height:
Max. 100 mm
Number of characters:8 characters, 12 x 8 Pixel each
Reading distance:
up to 40 m
Symbol colour:
red, yellow
Types of presentation:Still, running, blinking texts, alternating texts
Lettering:
according to customer's instructions with P, arrow, name of the car park and coloured operator's logo; background lighting
Device mounting:Prepared for wall mounting and mast mounting
Operating temperature:-20 +50 C
Air humidity:Hoseproof and dustproof (IP65)
Supply voltage:100 240 V / 50 60 Hz
Power consumption:approx. 100 W
Approx. 200 W with background lighting switched on
Approval:- CE mark
- Electrical safety acc. to EN 60950
- Radio interference acc. to EN 50081-1 (residential area)
- Jamming resistance. to EN 50082-2 (industrial area)
( Display of remaining lots with LED / LCD displayThe displays are project-specifically designed in coordination with the customer. Therefore, the dimensions vary depending on the functionalities.
The following examples show a selection of already realized displays of remaining lots.
(LCD display(LED display)
(LED display)
(LED display)
Description of the LED displayApplication:
Exterior installation, well readable even with direct sun exposureDevice type:
Complete device, ready for connection as flush version, one-side display
Symbol height:
Max. 100 mm
Number of characters:4 characters, 12 x 8 Pixel each
Reading distance:
up to 40 m
Housing dimensions:approx. 160 x 420 mm
Display surface (H x W):approx. 100 x 360 mm
Symbol colour:
yellow
Operating temperature:-20 +50 C
Air humidity:10 90 % (not condensing)
Supply voltage:100 240 V / 50 60 Hz
Power consumption:approx. 50 W
Approval:- CE mark
- Electrical safety acc. to EN 60950
- Radio interference acc. to EN 50081-1 (residential area)
- Jamming resistance. to EN 50082-2 (industrial area)
7 Mounting of the Device
For mounting, stay bolts of Messrs. Fischer are recommended. These bolts have the technical approval and therefore guarantee the required strength und application safety.
FAZ 10/50FAZ-A4 10/30
dDiameter of the drill (mm)1010
tMin. depth of the borehole (mm)130110
hMin. anchoring depth (mm)6060
lOverall length (mm)133113
nMax. effective length (mm)5030
ThreadM 10M 10
Wrench size across flats (mm)1717
Torque (Nm)4545
Materialelectrogalvanizedrustproof steel
The above stay bolts can also be ordered from S&B directly:
- FAZ 10/50:S&B 50 82334
- FAZ-A4 10/30:S&B 50 82335
- Cap nut:
S&B 70 03037
- Plain washer:S&B 70 03177
8 Wiring Diagram
8.1 Legend
Devices:
(Central computer (POS20, POS25, ZR20)
(Entry control (PGL20, PGL25, PGL30)
(Passage and exit control (PL20, PL25, PL30)
(Barrier (AS20, AS2000, AS30, AS35)
(Automatic pay station for cash payment (PKA20, PKA25, PKA26)
(Automatic pay station for non-cash payment (PAY20)
(Entry / exit / passage control PCX35
(Door reader PTL35
(Door reader PTL36
(Information sign
(Intercom central office
Cables/tubes:
(0)Empty tube EN20
(1)Mains supply 3 x 2,5 230V~ 10 % 16A, protected by separate fuses(2)Mains supply 4 x 2,5 230V~ 10 % 16A, protected by separate fuses for a permanent phase and an illumination phase(3)Power cable 3 x 2,5
(4)Power cable 5 x 2,5
(6)Control cable 2 x 2 x 0,8 (max. 1000m with PCX35, PTL35, PTL36 with RS485)(6*)If Ethernet is used, CAT5 cable must be used instead of (6)
(max. 95 m).
(8)Control cable 6 x 2 x 0,8 (with RS485 max. 1000m)(9)5-fold multipoint connector, to be provided by the customerOther notes:
-All power cables NYY or NYM.
-All control cables screened A2YF(L)2YST ||| BD (VDE 0816)or JE-Y(ST)YBD SI (VDE 0815).
-All cables to be provided and laid by the customer.
-All cables must be laid with a reserve length of approx. 1.5 m.
-The cross sections stated for mains supply cables apply up to a maximum length of 150 m.
-Larger cross sections must be used in the case of longer supply cables.
8.2 Safety Instructions
The electrical installation must be made in accordance with the EVU provisions for electrical connections and the VDE provisions DIN VDE 0100 Part 702, as well as in accordance with the rules for the prevention of accidents concerning electrical installations and equipment UBG 4 and GUV 2.10.
According to EN standard 60950 and IEC standard 60950 a leakage current >3.5 mA per device is permissible in the case of stationary consumers with pluggable or firmly connected mains connection.
This must be taken into consideration when planning the personal protection by means of residual current operated devices in the mains supply.
Depending on the number of devices, several residual current operated devices must be used.
9 Information about Power Supply and Overvoltage Protection
9.1 General Information
The devices of the Car Park Management System Families are tolerant concerning voltage fluctuations. Partially the devices are provided with a buffer battery in order to complete the just started booking procedure in a defined way in the case of power failure. In addition, even longer periods of power failure can be bridged by using "Uninterruptible power supply (UPS). The buffer period depends on the UPS capacity. In this case, the devices are shut down automatically in order to avoid damage to the devices.
However, short overvoltages due to lightning stroke may cause damage to the devices and downtime. The legally required and device-specifically standardized jamming resistance tests have been carried out for all the devices mentioned.
On principle, devices at exposed locations are particularly endangered by lightning stroke. This includes automatic pay stations as well as entries and exits in open space. The operator is responsible for the overvoltage protection.
Overvoltage protection measures can also be carried out by Scheidt & Bachmann. Quotations will be prepared upon special request. The expenditure strongly depends on the facilities already existing on the site, e.g. power supply and network components. Network connections by means of optical cables, for example, are less endangered by lightning stroke that a network on the basis of copper cables.
9.2 Information about Screening
9.2.1 LON networks
If there is no LON distributor plate (only a few field devices), the screening is applied only one-sided on the field device.
If there is a LON distributor plate, screening is made on both sides between the field device and the LON distributor plate. Between the cell computer/POS and the LON distributor plate the screening is only made one-sided on the cell computer.
9.2.2 RS485 networks
The screening is made on the connection box S2000 coming from the POS by means of an earth clip connected to the ground. On the field devices, the screening is left open, i.e. not connected. The two leads of the dialogue signals must be twisted into a pair of leads. The Gnd connection must be connected with the GND of the field device. Never use the screening for Gnd!
9.2.3 Ethernet networks
The LAN cable coming from the ground must be applied to a CAT5 coupling in the device, which is connected with the earthing of the housing.
9.2.4 Power Supply PTL36
The PTL36 is provided with an integrated rectifier so that it can be operated with 8 -12V dc or ac voltage. It must be ensured that screened lines are used for voltage supply. The screening must be applied one-sided on the power pack or on the earthing bar connected to the power pack.
List of illustrations86 86881 (c) PGL20S_B PL20S_B_e986 60095 (-) LKW-Bus Adapter fr PGL20_e1086 86993 (-) Fundamentrahmen PGL201186 85257 (c) PGL_PL20C_e1386 61805 (-) PGL_PL30 Ansicht_e1586 61805 (-) PGL_PL30 Fundamentplan_e1686 68468 (c) MKG_e1786 68470 (a) MKG-Fundamentplan_e1886 79552 (a) MKG Wandmontage_e1886 86501 (-) MKG-LKW_e1986 86501_2 (-) Fundamentplan MKG-LKW_e2086 60810 (b) PCX35 Ansicht2386 60810 (b) PCX35 Fundamentplan_e24PCX Steckleser (-)25MaxiProx2704 24597 (a) Regenschute PGL_PL_e28Regenschute an PGL20_S_e2886 85055 (f) Schranke AS20_e3186 86994 (-) Fundamentrahmen AS20_e3286 61806 (a) AS30_e3486 61794 (-) AS35_e36Schrankenbaum3786 95305 (-) Formstck Schranke3886 86984 (-) Fertigungshinweis3886 61022 (-) AS2000 5m_e3986 61584_1 (e) Flachstahlinsel_e4086 61584_2 (e) Flachstahlinsel_e4186 61584_3 (e) Flachstahlinsel_e4286 61584_4 (e) Flachstahlinsel_e4386 60428 (a) Rundrohr-Insel_e4486 60818 (-) Rammschutzbgel4586 60819 (-) Rammschutzbgel_2 PGL_PL4686 60820 (-) Rammschutzbgel_AS4786 68017 (f) Schleifenverlegung_e4986 67748 (a) Schleifen_e5086 71667 (a) Kabelschutzrohr Induktionsschleifen_e5186 85046 (d) Lageplan EF_e5286 85046 (d) Lageplan AF_e5201 082801 Wechselspur_e5386 85046 (d) Lageplan PH Standard_e5386 90464 (b) Ausfahrtskassierung_e5486 91662 (-) Ausfahrtskassierung_Detail5586 60789 (a) PKA Masszeichnung_e5786 65447 (d) Fundamentplan PKA_e5886 60789 (a) Befestigung Stahlsockel_e5986 86995 (-) Fundamentrahmen PKA2x_e60Einbaunische PKA20_e61Beleuchtungsaufsatz_e6186 60218_1 (a) berdachung_e6286 60218_2 (a) berdachung_e6386 61757 (-) Kassenhausunterstand_e64PKA Dach_e65PAY20_e6704 26140 (a) PAY20-Sockel6786 60802 (a) PTL35_e70PTL35 Wandbefestigung_e7186 60935 (-) PTL36 Ansicht7386 60935 (-) Wandmontage_e7386 60069 (-) Mast_e7486 60015 (-) Fundamentrahmen fr Signalmast_e7586 61282 (-) Rahmen Fundamentkorb_e7686 86944 (-) Blech Fundamentkorb7686 62940 (c) Transparentmast_e7786 65017 (e) Stahlmast-Fundament_e7886 79185 (a) Wechseltransparent_Wandmontage_e79Signal_180Signal_2_e80Signal_381Einlegeschablonen81Kleines Hinweistransparent_e8386 86372 (b) Kl. Wechseltransparent_e84Hinweistransparent_e85Transparent_d86LED-Transparent_e88
Scheidt & Bachmann GmbHPlanning ManualPlanning Manual_e.docSystems for Car Parks and Leisure CentresVersion 1.0
www.scheidt-bachmann.de86 93587Page 1 of 98
_1169451026.doc
Display
Ticket
insert
_1169454583.doc
4
2
0
415
min. 840
min. 170
m
i
n
.
1
3
3
0
560
70
Area for device opening
Tray as
rain protection
_1169295630.doc
Formed part (86 95305)
Arm profile with warning marks
(Colour and distance
project-specific)
Rubber
profile
Rubber profile
End pieces of formed part glued -
in hollow part of the profile bar