PLUMBER’S QUICK GUIDE
METHOD 1 WITHOUT CANISTER, WITH VENT
2 1/2"
2 1/2" 2"
2 1/2" X 18"
TO PUMP WATERLINE
SDX22ND SUCTION OUTLET
VACUUM BREAKER
MDXR3
(VENT TO AIR)
5 FT. MIN.5 1/2 FT. MAX.
PLUG 2 1/2" SIDE PORT(IF NOT USING HYDROSTAT,
PLUG 2" PORT)
Trunk line must be sized to meet maximum velocity requirements for suction plumbing per local code.
OPTIONAL
Canister layoutSet canister at same level as skimmer
Standard Rough-in for 35/8” Cantilever DeckTop of rim 1” above form to level with form
Note: Decks over 4” thick may require a lid extenstion
Excavation rough-out 24” x 24” x 36”
MDXR3 Anti-Entrapment Debris Drain with Canister
Floor and Step Riser
MDXR3
WATERLINE
OPTIONAL
2"
TO PUMP
2 1/2"
2 1/2"2 1/2" X 18"
SDX22ND SUCTION OUTLET
PLUG 2 1/2" SIDE PORT(IF NOT USING HYDROSTAT,
PLUG 2" PORT)
VACUUM BREAKER(VENT TO AIR)
5 FT. MIN.5 1/2 FT. MAX
Trunk line must be sized to meet maximum velocity requirements for suction plumbing per local code.
MDXR3 Anti-Entrapment Debris Drain without Canister
Returns
Valve CircuitLayout
Cut pipe even with gunite
See manual for additional installation instructions
See manual for additional installation instructionsMADE IN USA
1.800.621.5886www.1Paramount.com
004-027-7821-00 Rev 042809 PVT0796
1 Side Drain and optional vent (SVRS)
1 Side Drain and optional vent (SVRS)
METHOD 1 CA WITH CANISTER, WITH VENT
5 1/2 FT. MAX5 FT. MIN.
MDXR3
2ND SUCTION OUTLET SDX2
WATERLINE
VACUUM BREAKER(VENT TO AIR)
2"
TO PUMP
2 1/2"PLUG 2 1/2" SIDE PORT(IF NOT USING HYDROSTAT, PLUG 2" PORT) EQUAL SIZE AND LENGTH
FROM TEE TO EACH DRAIN
Trunk line must be sized to meet maximum velocity requirements for suction plumbing per local code.
OPTIONAL
MDXR3 Anti-Entrapment Debris Drain with Canister
See manual for additional installation instructions
California must use this method.1 Side Drain and optional vent (SVRS)
Consult MDXR3 Installation Manual for Florida Method
PLUMBER’S QUICK GUIDE
Rotary Nozzle Placement
1. Floor nozzle maximum cleaning radius plaster six feet.
2. Floor nozzle maximum cleaning radius pebble 5 ½ feet.
3. Cleaning nozzles must be placed three feet from finishwall. In corners the nozzle will be two feet from one walland three feet from the other wall.
4. 3/8” nozzles are normally used on steps & benches andhave a cleaning distance of five feet. Allow a one-footoverlap for large steps and benches and steps that have asidewall. (5/8” nozzles may be used on lower steps)
5. ¼” nozzles should be used on top steps if possible.
6. Water flow does not bend. The area to be cleaned mustbe in the line of sight of the nozzle.
7. If pool has a break treat it as a wall and place nozzles onboth sides of the break.
8. Cleaning nozzles in raised spas or fountains must have acheck valve at the water valve.
MDXR3 Anti-Entrapment Debris Drain
9. Main drain should be plumbed in 2½” pipe. Never use90 ells, the main drain should be a minimum of seven feetfrom the deep end wall, nine feet is preferred.
Equipment Plumbing
10. Heater must have a minimum one-inch external bypass onsingle pump systems or preferably a valved line.
11. Solar must have a booster pump.
12. Multi port valves, with the exception of Pac Fab’s twoinch #26-1055 or 52 multi port, have too much restrictionand should not be used on single pump systems.
Remember:
• 60 gpm systems nozzle per floor circuit = three 5/8”nozzles/20 gpm.
• 60 gpm systems nozzle per step circuit = six 3/8”nozzles/10 gpm.
• 60 gpm systems with mixed nozzle sizes on line must addup to 60 gpm.
• 40 gpm systems nozzle per floor circuit = two 5/8”nozzles/20 gpm.
• 40 gpm systems nozzle per floor circuit = four 3/8”nozzles/20 gpm.
• 40 gpm systems with mixed nozzle sizes on line must addup to 40 gpm.
SDX218”
Single Pump
200
SDX218”
Dual Pump
*Numbers correspond to text on previous page.
PV3 Layout Example Two
*Numbers correspond to text on previous page.
PV3 Layout Example One
MDXR3
MDXR3