Universiti Kuala Lumpur Malaysia France InstituteIndustrial Automation Section
Practical : PLC-CS1W-ETN-21(Ethernet Unit)
Industrial Networking By : Lukman Hakim
Objective The objective of this practical is to introduce the configuration and set-up of PLC Ethernet controller unit.
Hardware1. Omron PLC CS1G-H training kit2. 1 unit of Ethernet Unit CS1W-ETN213. CX programmer software version 5.0 and latest4. Serial programmer cable with 9 pins D-connectors (SYSMAC-
WAY), UTP cable with RJ-45 connectors.
Implementation1. Turn ON the PC and log on as Administrator/Lecturer.
2. Go to Start Menu > Control Panel > Network and
Internet Connection > Network Connections
3. Right click of the icon Local Area Connection and select
Properties.
4. Select Internet Protocol (TCP/IP) and then select properties.
5. In General window, select Use the following IP address
Figure 1: Local Area Connection properties
Page 1 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 2/8
6. Enter the following:
IP address: 192.168.197.XXX
Subnet mask : 255.255.255.0
Note:
XXX refers to the PC/node number. This number must be
unique.
Refer to Appendix A.
7. Verify the correct IP and click OK.
8. Turn ON the PLC training kit and connect the serial programming
cable from PC to PLC.
9. Run CX-Programmer. Open new project and configure device
type and network type. Refer to PLC CPU unit for device type and
use SYSMAC WAY as the network type.
Figure 2: PLC setup window
10. Go to PLC > work online the PLC . Change the PLC operating
mode to Programming mode .
Page 2 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 3/8
11. Select I/O Table in the object browser window.
Figure 3: IO table and unit setup
12. In the I/O Table window, go to Option > double click Download
form PLC. Click Transfer
Figure 4: IO table dialog box
Page 3 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 4/8
13. Expand the main rack and look for Ethernet unit.
Figure 5: Main Rack
14. Right click on the Ethernet unit and select unit setup.
Figure 6: CS1W-ETN21 dialog box
Page 4 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 5/8
15. Find the node address number as specified at the cover of the
ETN-21 unit (Hardware switch on the PLC). The Value is in
Hexadecimal.
16. Write down the value (in hexadecimal) of the ETN-21 node
address number here:
____________________________________________________________
17. Convert the value of node address number to decimal and write
the value here:
Page 5 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 6/8
____________________________________________________________
18. Check also the setting of Unit Number hardware switch.
Write the value here:
_______________________________________________________________
19. The IP address of the Ethernet unit is given by 192.168.197.YYY
and the subnet mask is 255.255.255.0. ( YYY refers to the
decimal value of the ETN-21 node address number)
1. Enter the above IP address and subnet mask. Then select
Transfer to PLC.
2. After the transmission is finished successfully, close the window
and Off line the PLC.
3. At your PC, go to Stat menu > run and type cmd
4. Select OK. A WINDOW DOS pop up. Type ping
192.168.197.YYY
5. If there is a reply, it means that the communication PC to PLC is
established.
Page 6 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 7/8
6. Go to CX-programmer, Go to object browser window and select
the PLC name.
7. Change the Network type from SYSMAC WAY to Ethernet.
8. In the Ethernet setting, go to Driver tab, and enter the IP address
of the PLC.
9. Go to PLC > work online
10. Verify that the PC can work online to the PLC successfully.
Page 7 of 8 pages
8/3/2019 Pratical Plc Ethernet_new Ver
http://slidepdf.com/reader/full/pratical-plc-ethernetnew-ver 8/8
11. Write a simple ladder diagram and transfer it to PLC. Verify that
the transmission speed is faster compared to SYSMAC WAY.
12. Try to connect to PLC at adjacent work station.
END OF PRACTICAL
APPENDIX A: LAB B209 LAYOUT
Page 8 of 8 pages
PC 5
PC 4
PC 3
PC 2
PC 1
PC 6
IP: 192.168.197.106
IP: 192.168.197.105
IP: 192.168.197.104
IP: 192.168.197.103
IP: 192.168.197.102
IP: 192.168.197.101