R. Shanthini 10 May 2010_modified
1
PM3125
Content of Lectures 1 to 6:
Heat transfer: • Source of heat • Heat transfer • Steam and electricity as heating media• Determination of requirement of amount of
steam/electrical energy • Steam pressure• Mathematical problems on heat transfer
uploaded at http://www.rshanthini.com/PM3125.htm
R. Shanthini 10 May 2010_modified
4
Units of Heat• The SI unit is the joule (J),
which is equal to Newton-metre (Nm).
• Historically, heat was measured in terms of the ability to raise the temperature of water.
• The calorie (cal): amount of heat needed to raise the temperature of 1 gramme of water by 1 C0 (from 14.50C to 15.50C)
• In industry, the British thermal unit (Btu) is still used: amount of heat needed to raise the temperature of 1 lb of water by 1 F0 (from 630F to 640F)
R. Shanthini 10 May 2010_modified
5
Conversion between different
units of heat:
1 J = 0.2388 cal = 0.239x10-3 kcal = 60.189 Btu
1 cal = 4.186 J = 3.969 x 10-3 Btu
R. Shanthini 10 May 2010_modified
6
Sensible Heat
• What is 'sensible heat‘?
Sensible heat is associated with a temperature change
R. Shanthini 10 May 2010_modified
7
Specific Heat Capacity
• To raise the temperature by 1 K, different substances need different amount of energy because substances have different molecular configurations and bonding (eg: copper, water, wood)
• The amount of energy needed to raise the temperature of 1 kg of a substance by 1 K is known as the specific heat capacity
• Specific heat capacity is denoted by c
R. Shanthini 10 May 2010_modified
8
Calculation of Sensible Heat
where ΔT is the temperature change in the substance
Q = m c dT ∫ Q is the heat lost or gained by a substance
m is the mass of substance
c is the specific heat of substance which changes with temperature
T is the temperature
When temperature changes causes negligible changes in c,
Q = m c dT ∫ = m c ∆T
R. Shanthini 10 May 2010_modified
9
Calculation of Sensible Heat
When temperature changes causes significant changes in c,
Q = m c ∆T cannot be used.
Q = ∆H = m ∆h Instead, we use the following equation:
where ΔH is the enthalpy change in the substance
and ∆h is the specific enthalpy change in the substance.
To apply the above equation, the system should remain at constant pressure and the associated
volume change must be negligibly small.
R. Shanthini 10 May 2010_modified
10
Calculation of Sensible Heat
Q = m c ΔT (since c is taken as a constant)
= (300 g) (0.896 J/g oC)(70 - 25)oC
= 12,096 J
= 13.1 kJ
Calculate the amount of heat required to raise the temperature of 300 g Al from 25oC to 70oC.
Data: c = 0.896 J/g oC for Al
R. Shanthini 10 May 2010_modified
11
Exchange of Heat
Heat lost by iron = Heat gained by water
(m c ΔT)iron = (m c ΔT)water
(100 g) (0.452 J/g oC)(80 - tf)oC
= (53.5 g) (4.186 J/g oC)(tf - 25)oC
80 - tf = 4.955 (tf -25)
tf = 34.2oC
Calculate the final temperature (tf), when 100 g iron at 80oC is tossed into 53.5g of water at 25oC.
Data: c = 0.452 J/g oC for iron and 4.186 J/g oC for water
R. Shanthini 10 May 2010_modified
12
Latent Heat
• What is ‘latent heat‘?
Latent heat is associated with phase change of matter
R. Shanthini 10 May 2010_modified
14
Phase Change• Heat required for phase changes:
» Melting: solid liquid
» Vaporization: liquid vapour
» Sublimation: solid vapour
• Heat released by phase changes:» Condensation: vapour liquid
» Fusion: liquid solid
» Deposition: vapour solid
R. Shanthini 10 May 2010_modified
16
Phase Diagram: Water
Saturated steam
Superheated steam
Saturated liquidCompressed liquid
R. Shanthini 10 May 2010_modified
17
Phase Diagram: WaterExplain why water is at liquid
state at atm pressure
R. Shanthini 10 May 2010_modified
18
Phase Diagram: Carbon DioxideExplain why CO2 is at gas state
at atm pressure
Explain why CO2 cannot be made a
liquid at atm pressure
R. Shanthini 10 May 2010_modified
19
Latent Heat
Latent heat is the amount of heat added per unit mass of substance during a phase change
Latent heat of fusion is the amount of heat added to melt a unit mass of ice OR it is the amount of heat removed to freeze a unit mass of water.
Latent heat of vapourization is the amount of heat added to vaporize a unit mass of water OR it is the amount of heat removed to condense a unit mass of steam.
R. Shanthini 10 May 2010_modified
20
Water: Specific Heat Capacities and Latent Heats
Specific heat of ice ≈ 2.06 J/g K (assumed constant)
Heat of fusion for ice/water ≈ 334 J/g (assumed constant)
Specific heat of water ≈ 4.18 J/g K (assumed constant)
Latent heat of vaporization cannot be assumed a constant since it changes significantly with the pressure,
and could be found from the Steam Table
How to evaluate the sensible heat gained (or lost) by superheated steam?
R. Shanthini 10 May 2010_modified
21
Water: Specific Heat Capacities and Latent Heats
How to evaluate the sensible heat gained (or lost) by superheated steam?
Q = m c ∆T cannot be used since changes in c with changing
temperature is NOT negligible.
Q = ∆H = m ∆h Instead, we use the following equation:
provided the system is at constant pressure and the associated volume change is negligible.
Enthalpies could be referred from the Steam Table
R. Shanthini 10 May 2010_modified
22
Properties of SteamLearnt to refer to Steam Table to find properties of steam such as saturated (or boiling point) temperature and latent heat of vapourization at give pressures, and enthalpies of superheated steam at various pressures and temperatures.
Reference:
Chapter 6 of “Thermodynamics for Beginners with worked examples” by R. Shanthini
(published by Science Education Unit, Faculty of Science, University of Peradeniya)
(also uploaded at http://www.rshanthini.com/PM3125.htm)
R. Shanthini 10 May 2010_modified
23
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
-20oC ice
R. Shanthini 10 May 2010_modified
24
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
-20oC ice
0oC melting point of ice
R. Shanthini 10 May 2010_modified
25
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
-20oC ice
0oC melting point of ice
120.2oC boiling point of water at 2 bar
Boiling point of water at 1 atm pressure is 100oC. Boiling point of water at 2 bar is 120.2oC. [Refer the Steam Table.]
R. Shanthini 10 May 2010_modified
26
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
-20oC ice
0oC melting point of ice
120.2oC boiling point of water at 2 bar
150oC superheated steam
Specific heat
Specific heat
Specific heat
Latent heat
Latent heat
R. Shanthini 10 May 2010_modified
27
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
Specific heat required to raise the temperature of ice from -20oCto 0oC= (2 kg) (2.06 kJ/kg oC) [0 - (-20)]oC = 82.4 kJ
Latent heat required to turn ice into water at 0oC= (2 kg) (334 kJ/kg) = 668 kJ
Specific heat required to raise the temperature of water from 0oC to 120.2oC
= (2 kg) (4.18 kJ/kg oC) [120.2 - 0)]oC = 1004.9 kJ
R. Shanthini 10 May 2010_modified
28
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
Latent heat required to turn water into steam at 120.2oC and at 2 bar= (2 kg) (2202 kJ/kg) = 4404 kJ
[Latent heat of vapourization at 2 bar is 2202 kJ/kg as could be referred to from the Steam Table]
Specific heat required to raise the temperature of steam from 120.2oC to 150oC
= (2 kg) (2770 – 2707) kJ/kg = 126 kJ
[Enthalpy at 120.2oC and 2 bar is the saturated steam enthalpy of 2707 kJ/kg and the enthalpy at 150oC and 2 bar is 2770 kJ/kg as could be referred to from the Steam Table]
R. Shanthini 10 May 2010_modified
29
Warming curve for waterWhat is the amount of heat required to change 2 kg of ice
at -20oC to steam at 150oC at 2 bar pressure?
Total amount of heat required
= 82.4 kJ + 668 kJ + 1004.9 kJ + 4404 kJ + 126 kJ
= 6285.3 kJ
R. Shanthini 10 May 2010_modified
30
Application: Heat ExchangerIt is an industrial equipment in which heat is transferred from a hot fluid (a liquid or a gas) to a cold fluid (another liquid or gas) without the two fluids having to mix together or come into direct contact.
Hot fluid at TH,in Hot fluid
at TH,out
Cold fluid at TC,out
Cold fluid at TC,in
Heat lost by the hot fluid = Heat gained by the cold fluid
R. Shanthini 10 May 2010_modified
32
Heat Exchanger
mhot chot (TH,in – TH,out) = mcold ccold (TC,out – TC,in). .
Heat lost by the hot fluid = Heat gained by the cold fluid
mass flow rate of hot fluid
Specific heat of hot fluid
mass flow rate of cold fluid
Specific heat of cold fluid
Temperature decrease in the hot fluid
Temperature increase in the cold fluid
R. Shanthini 10 May 2010_modified
33
Heat Exchanger
mhot chot (TH,in – TH,out) = mcold ccold (TC,out – TC,in). .
Heat lost by the hot fluid = Heat gained by the cold fluid
The above is true only under the following conditions:
(1) Heat exchanger is well insulated so that no heat is lost to the environment
(2) There are no phase changes occurring within the heat exchanger.
R. Shanthini 10 May 2010_modified
34
Heat Exchanger
Heat lost by the hot fluid = Heat gained by the cold fluid
+ Heat lost to the environment
If the heat exchanger is NOT well insulated, then
R. Shanthini 10 May 2010_modified
35
High pressure liquid water at 10 MPa (100 bar) and
30oC enters a series of heating tubes. Superheated
steam at 1.5 MPa (15 bar) and 200oC is sprayed over
the tubes and allowed to condense. The condensed
steam turns into saturated water which leaves the
heat exchanger. The high pressure water is to be
heated up to 170oC. What is the mass of steam
required per unit mass of incoming liquid water?
The heat is assumed to be well insulated (adiabatic).
Worked Example in Heat Exchanger
R. Shanthini 10 May 2010_modified
37
Solution: High pressure (100 bar) water enters at 30oC and leaves at 198.3oC.Boiling point of water at 100 bar is 311.0oC. Therefore, no phase changes in the high pressure water that is getting heated up in the heater.
Heat gained by high pressure water
= ccold (TC,out – TC,in)
= (4.18 kJ/kg oC) x (170-30)oC
= 585.2 kJ/kg
[You could calculate the above by taking the difference in enthalpies at the 2 given states from tables available.]
Worked Example in Heat Exchanger
R. Shanthini 10 May 2010_modified
38
Solution continued: Superheated steam at 1.5 MPa (15 bar) and 200oC is sprayed over the tubes and allowed to condense. The condensed steam turns into saturated water which leaves the heat exchanger.
Heat lost by steam
= heat lost by superheated steam to become saturated
steam
+ latent heat of steam lost for saturated steam to turn into
saturated water
= Enthalpy at 15 bar and 200oC
– Enthalpy of saturated steam at 15 bar
+ Latent heat of vapourization at 15 bar
= (2796 kJ/kg – 2792 kJ/kg) + 1947 kJ/kg = 1951 kJ/kg
Worked Example in Heat Exchanger
R. Shanthini 10 May 2010_modified
39
Solution continued:
Since there is no heat loss from the heater,
Heat lost by steam = Heat gained by high pressure water
Mass flow of steam x 1951 kJ/kg
= Mass flow of water x 585.2 kJ/kg
Mass flow of steam / Mass flow of water
= 585.2 / 1951
= 0.30 kg stream / kg of water
Worked Example in Heat Exchanger
R. Shanthini 10 May 2010_modified
40
Give the design of a heat exchanger which has the most effective heat
transfer properties.
Group Assignment 1
Learning objectives:1) To be able to appreciate heat transfer applications in pharmaceutical
industry
2) To become familiar with the working principles of various heat exchangers
3) To get a mental picture of different heat exchangers so that solving heat transfer problems in class becomes more interesting
R. Shanthini 10 May 2010_modified
41
Group Assignment 2 Steam enters a heat exchanger at 10 bar and 200oC and
leaves it as saturated water at the same pressure. Feed-water enters the heat exchanger at 25 bar and 80oC and leaves at the same pressure and at a temperature 20oC less than the exit temperature of the steam. Determine the ratio of the mass flow rate of the steam to that of the feed-water, neglecting heat losses from the heat exchanger.
If the feed-water leaving the heat exchanger is fed directly to a boiler to be converted to steam at 25 bar and 300oC, find the heat required by the boiler per kg of feed-water.