+ All Categories
Transcript
Page 1: S3-Series Reverse Osmosis SystemS3-Series Reverse Osmosis System Engineered Water Treatment Solutions S3-Series Reverse Osmosis Systems are engineered to treat are designed and manufactured

S3-Series Reverse Osmosis System

Engineered Water Treatment Solutions

S3-Series Reverse Osmosis Systems

are engineered to treat are designed and

manufactured for seawater applications

specifically tailored for capacities ranging

from 600 - 2,200 gallons per day. The S3 -

Series Reverse Osmosis Systems feature a

unique and innovative compact design that

allows for easy installation in any size area.

The S3 - Series is also equipped with premium

components which include a 316 plunger -

type pump for high performance and

corrosion resistance, a high grade corrosion

resistant aluminum frame, a programmable

computer controller with many built - in

features, fiberglass membrane housings for

durability.

Standard Features ■ S150 Computer Controller

■ LCD Backlit Display

■ Pre-Treatment Lockout

■ Tank Level Input

■ Low Pressure Monitoring and Alarm

■ Dual TDS Monitoring

■ Hour Meter

■ Feed Flush

■ High Rejection Seawater Membranes

■ Fiberglass Membrane Housings

■ AXEON 5 Micron Sediment Pre-Filter

■ AXEON® by Pentair® Single O-Ring Cartridge Housing

■ Permeate and Concentrate Flow Meters

■ AXEON 0–100 psi 316-SS Glycerin-Filled Pre-Filter

■ Pressure Gauge

■ 0–100 psi Pre-Filter Out Pressure Gauge

■ 0–1500 psi Concentrate Pressure Gauge

■ Plast-O- Matic Feed Solenoid Valve

■ AXEON 316 Stainless Steel Needle Valve

■ SS Feed Low Pressure Switch

■ SS Pump High Pressure Switch

■ CAT® 316L High Pressure Pump

■ TEFC Motor with Thermal Motor Protection

■ Chemical Pump Outlet

■ Powder Coated Aluminum Frame

■ High Pressure 316 Stainless Steel Tubing and Fittings

■ High Pressure Hose with Reusable SS Fittings

Page 2: S3-Series Reverse Osmosis SystemS3-Series Reverse Osmosis System Engineered Water Treatment Solutions S3-Series Reverse Osmosis Systems are engineered to treat are designed and manufactured

Options and Upgrades ■ Booster Pump ■ High Pressure Tank Switch ■ Permeate Divert Valve

■ Fresh Water Flush ■ Ultraviolet Light ■ Wooden Crate

Benefits ■ Fully Equipped and Customizable ■ High Quality Components ■ Individually Tested and Preserved ■ Low Operating and Maintenance Costs

■ Easy Maintenance and Servicing ■ Pre-Plumbed, Wired and Assembled ■ 1-Year Limited Warranty ■ Made in the U.S.A.

4 1 25S3S-SERIES MODEL

HOUSING QUANTITY DESIGNATION

MEMBRANE QUANTITY PER HOUSING

2.5 INCH MEMBRANE DIAMETER

AXEON Naming Matr ix

S3 Sea Water Mode l

1 1 Vesse l2 2 Vessel3 3 Vessel4 4 Vessel

1 1 Membran e

S3-4125 Reverse Osmosis System

Page 3: S3-Series Reverse Osmosis SystemS3-Series Reverse Osmosis System Engineered Water Treatment Solutions S3-Series Reverse Osmosis Systems are engineered to treat are designed and manufactured

1. All dimensions are given in inches.2. S3-4125 AXEON® model shown.

Notes:

Array SpecificationsModels Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity

S3-1125 1 2540 1 2540 1

S3-2125 1:1 2540 2 2540 2

S3-3125 1:1:1 2540 3 2540 3

S3-4125 1:1:1:1 2540 4 2540 4

Page 4: S3-Series Reverse Osmosis SystemS3-Series Reverse Osmosis System Engineered Water Treatment Solutions S3-Series Reverse Osmosis Systems are engineered to treat are designed and manufactured

S3-Series Reverse Osmosis System

P: 800-320-4074 • W: www.axeonwater.comF: 800-609-0829 • E: [email protected] Country Center Drive, Suite 100, Temecula, CA 92591

MKTF-108-B AXEON is a registered trademark of AXEON Water Technologies. 01/2016 © 2016 AXEON Water Technologies

SpecificationsModels S3-1125 S3-2125 S3-3125 S3-4125

Design

System Capacity gpd (lpd) 600 (2,271) 1,200 (4,542) 1,800 (6,814) 2,200 (8,328)

Configuration Single Pass Single Pass Single Pass Single Pass

Feed Water Source*** (ppm) TDS < 45,000 ppm TDS < 45,000 ppm TDS < 45,000 ppm TDS < 45,000 ppm

Standard Recovery Rate 15% 20% 25% 36%

Rejection and Flow RatesNominal TDS Rejection 99% 99% 99% 99%

Permeate Flow* gpm (lpm) 0.41 (1.55) 0.83 (3.14) 1.25 (4.73) 1.52 (5.75)

Minimum Feed Flow gpm (lpm) 4.2 (15.9) 4.2 (15.9) 4.2 (15.9) 4.2 (15.9)

Maximum Concentrate Flow gpm (lpm) 6 (22.7) 6 (22.7) 6 (22.7) 6 (22.7)

ConnectionsFeed (in) ½ FNPT ½ FNPT ½ FNPT ½ FNPT

Permeate (in) ⅜ TUBING ⅜ TUBING ⅜ TUBING ⅜ TUBING

Concentrate (in) ⅜ TUBING ⅜ TUBING ⅜ TUBING ⅜ TUBING

MembranesMembranes Per Vessel 1 1 1 1

Membrane Quantity 1 2 3 4

Membrane Size 2540 2540 2540 2540

VesselsVessel Array 1 1:1 1:1:1 1:1:1:1

Vessel Quantity 1 2 3 4

PumpsPump Type Plunger Plunger Plunger PlungerMotor (hp) 2.5 (1.85) 2.5 (1.85) 2.5 (1.85) 2.5 (1.85)RPM @ 60 (50 Hz) 1725 (1450) 1725 (1450) 1725 (1450) 1725 (1450)

Electrical

Standard Voltage 220 VAC, 1Ph 220 VAC, 1Ph 220 VAC, 1Ph 220 VAC, 1Ph

System Dimensions**

L x W x H (in / cm) 48 x 24 x 18.5(122 x 61 x 47)

48 x 24 x 18.5(122 x 61 x 47)

48 x 24 x 18.5(122 x 61 x 47)

48 x 24 x 18.5(122 x 61 x 47)

Weight (lb / kg) 145 (65.77) 155 (70.31) 165 (74.84) 175 (79.38) * Product flow and recovery rates are based on equipment test parameters.** Does not include operating space requirements.*** Treatment ability of the RO system is dependent on feed water quality. Performance projections must be run for each installation.

Operating LimitsMaximum Feed Temperature (°F / °C)* 85 (29) Maximum Free Chlorine (ppm) 0Minimum Feed Temperature (°F / °C)* 40 (4.4) Maximum TDS (ppm) 45,000

Maximum Ambient Temperature (°F / °C) 120 (48.9) Maximum Hardness (gpg) 0Minimum Ambient Temperature (°F / °C) 40 (4.4) Maximum pH (Continuous) 11

Maximum Feed Pressure (psi / bar) 50 (3.4) Minimum pH (Continuous) 5Minimum Feed Pressure (psi / bar) 5 (0.3) Maximum pH (Cleaning 30 Min.) 12

Maximum Operating Pressure (psi / bar) 1000 (68.95) Minimum pH (Cleaning 30 Min.) 2Maximum SDI Rating (SDI) <3 Maximum Turbidity (NTU) 1

Test Parameters: 35,000 TDS Filtered (5 Micron), De-Chlorinated, Feed Water, 65 psi (4.5 bar) Feed Pressure, 850 psi (58.61 bar) Operating Pressure, 77 Degrees F (25 Degrees C), Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.


Top Related