59 Series Self-Draining Vacuum Breakers
Self-Draining Vacuum BreakersLead-Free, Freeze-Prevention Back-Flow Preventers
Features & Benefits• Lead free brass construction• Protects your water supply
from harmful contaminates• Automatic self-draining:
enables faucet to automatically drain when shut off, preventing damage from freezing
• Break-away set screw to prevent theft or loss of device
• 3-year limited warranty
• Available in standard hose thread inlet (“ABP”), or factory fine machine thread (“BFP”)
• ASSE 1019-A certified by IAPMO
• Available in brass or nickel plated finish (“CHR” models)
• Sold as individually boxed (58 items) or clamshell packaged (PK items)
Self-Draining Vacuum Breaker
Chrome Fine Thread Self-Draining VB
Chrome Plated Self-Draining VB
Fine Thread Self-Draining VB
Chrome Fine Thread Self-Draining VB
59 Series Self-Draining Vacuum Breaker
Freeze-Prevention Back-Flow Preventers
# 59ABP # 59ABPCHR # 59BFP # PK1390# 59BFPCHR3/4” hose thread inlet x 3/4” hose thread outlet- brass finish
3/4” hose thread inlet x 3/4” hose thread outlet- chrome plated finish
1-1/16” fine/machine thread inlet x 3/4” hose thread outlet
Clamshell Packaged- 59BF-PCHR fine thread, chrome plated Self-Draining VB
1-1/16” fine/machine thread inlet x 3/4” hose thread outlet- nickel plated finish
ARROWHEAD BRASS
6
0ARROWHEAD BRASS
6
01019-A
Arrowhead Brass & Plumbing, LLC 5147 Alhambra Ave., Los Angeles, CA 90032Tel: (323) 221-9137 | Fax: (323) 221-2579 | Email: [email protected] | Website: www.arrowheadbrass.com© Copyright: 2016 Arrowhead Brass & Plumbing, LLC.
ABP/
US/
08.1
7
1-1/16” FINE THREADS (6 COUNT)
TOP SECTION
MIDDLE SECTION
BOTTOM SECTION
3/4” HOSE THREADS (4 COUNT)
1-3/16” FINE THREADS(3 COUNT)
Self-Draining Gasket
1-1/8” FINE THREADS(3 COUNT)
TOP SECTIONMust Be Removed
REPAIR NOTES:• TOP SECTION MUST BE REMOVED FROM FAUCET:
Ensure the fine thread top section of the original vacuum breaker is removed from the faucet before trying to install replacement. 6 fine threads should be visible. Hold the faucet body in place with channel locks while removing vacuum breaker (with pipe wrench or vise grips) to prevent damage to faucet.
• Use Liquid Thread Sealant on the fine threads when installing replacement.
• Set Screw on replacement/new vacuum breakers only. Tighten & cut off when installed to prevent removal
• After installation, vacuum breaker may need to be pressurized to work correctly:1. Hook up a hose with a closed nozzle attached
or kink the hose by hand. 2. Turn the faucet on FULL BLAST3. Once the hose fills, the vacuum breaker will
seal & stop leaking