siemens.co.uk/tip
Sivacon S4Low-Voltage Switchboards
Product Managers and dedicated Business Development Managers are available to assist with all your enquiries.
• Technical presentations (Forms of Separation, Discrimination etc) available
• Site response capability
• Site installation coordination
Sivacon S4 is manufactured in the UK
Siemens Low Voltage Products (LP)Sharston Road Wythenshawe Manchester M22 4RA
UK Sales:
Telephone: 01543 455010
Although every effort has been made to ensure accuracy in the compilation of this publication, specifications and performance data are constantly changing. Latest details can be obtained by contacting us.
© Siemens plc 2017
Safe and Intelligent power distribution
SIVACON S4. Mastering your power distribution requirements
• Compartmentalised and Group-Mounted designs
• Utilises Siemens 3VA MCCBs and 3WL ACBs
• Quick and easy installation
• Arc Containment to IEC 61641
• Full technical support
• Case studies available
• Fully Type tested to IEC/EN 61439
• Manufactured in the UK
• Compact with a flexible modular design
• Degrees of Protection IP30, 31, 40, 41, 55
• Busbar system to 3200A with Icw up to 100kA
• Forms of Separation: up to Form 4b Type 6
Sivacon S4, ‘at a glance’
• As part of Siemens Energy Management Division our job is to get energy from where it’s produced to where it’s used – as safely and efficiently as possible. Our customers need cost effective solutions which are fit for a low carbon world. Sivacon S4 is our main low voltage switchboard system in a range of solutions from primary power generation equipment through to a 13A socket.
• Suitable for commercial, industrial and infrastructure applications up to 3200 Amps.
• Consistent distribution and control of power with robust reliability and safety.
Sivacon S4 switchboard. 800A to 3200A.
Sivacon S4 switchboard. 800A to 3200A.
Sivacon S8 switchboard. 800A to 6300A.
3
Sivacon S4 | Low-Voltage Switchboards
4
Low-Voltage Switchboards | Sivacon S4
Features and BenefitsWith its modular and robust design, Sivacon S4 lends itself to numerous permutations, giving engineers scope to plan every last detail required for a project.
In compartmentalised form (shown here) devices are safely located in individual compartments that also help the Sivacon S4 system achieve Arc containment to IEC 61641. Operator personal safety is paramount.
IP3X ventilation slots in panel work can be incorporated to promote efficient thermal control
Safety is paramount when it comes to door security. All door hinges and locking systems have been rigorously tested to meet and exceed the requirements of IEC/EN 61439-2
Auto-change over options available
3WL ACB
3VA MCCBs with rotary handles
2.5mm thick galvanized steel frame parts are assembled to form a strong structure capable of resisting arduous service conditions for the lifetime of the switchboard
Internal separation, either Galvanised steel or Polycarbonate, providing robust partitioning between different internal parts of the switchboard
1.5mm thick treated steel Polyester/epoxy powder coated doors and panels fitted as standard. Hardwearing and attractive, providing a maintenance free ‘outer covering’ for the lifetime of the switchboard
The Sivacon S4 switchboard can be split into suitably sized units to facilitate ease of transport and improve access to awkward installation environments prior to final installation/assembly
Plinths with removable cover plates
Compartmentalised switchboard shown
Form 4a Type 2, Form 4b Type 5, Form 4b Type 6 solutions
Suitable Applications
• Data centres
• Health
• Oil & gas
• Heavy industrial
• Light industrial
• Offices
• Hotels and residential
• Food drink and process industries
• Educational
• Entertainment and leisure
5
Sivacon S4 | Low-Voltage Switchboards
6
Low-Voltage Switchboards | Sivacon S4
Capabilities and AttributesIn a Sivacon S4 Group-mounted switchboard MCCBs and other devices are efficiently placed to save both space and reduce capital outlay. Form of Separation; Form 4b Type 6 is achieved to conform to EN61439-2
• Accommodates 3VA MCCBs and 3WL main ACBs
• Accommodates; Single Pole, 3P & 4P fixed pattern devices
• All devices are operated with integral toggles
• All devices accessible behind a common overall door
• External covers removable only by a special tool
• Metered options available
• Form of Separation; Form 4b Type 6 Group-mounted
• Cost effective
• Smaller physical size compared to compartmentalised equivalent
Suitable Applications
• Light industrial
• Offices
• Hotels and residential
• Food, drink & process industries
• Educational
• Entertainment & leisureCompartmentalised and Group-mounted can also be incorporated into one Switchboard
3VA MCCB up to 800A Clear warning labels on secondary barriers
Door mounted metering, easily connected to BMS systems for greater control and monitoring
TP&N, 4-Pole & Single-pole configurations
3VA MCCBs up to 250A
3WL ACB
Integral Power Factor Correction available
Spare-ways for future devices
CTs for circuit power monitoring
Extended terminal shrouds to ensure compliance with IEC/EN 61439 Form 4b Type 6 Group-mounted
7
Sivacon S4 | Low-Voltage Switchboards
8
Low-Voltage Switchboards | Sivacon S4
Devices available for S4
Siemens 3WL ACBs
• Available in frame size I, II and III
• 3 or 4 pole versions available
• IP41 and IP55 ‘ingress protection’ options available
• Fixed and withdrawable
• Several optional protection releases
• Communication functions and integral metering options available
Surge protection devices
Sentron PAC meters, options available;
Siemens 3VA MCCBs
• Compact design
• Single-pole to 4-pole versions
• Breaking capacity of 150 kA... 70 kA at 415V
• Thermo magnetic and electronic tripping options
• AC/DC applications
• Modular and easy-to-fit internal accessories with diverse functions
• Communication & metering options available
*Power Factor Correction devices, Fused switches and other devices available.
Building Information Modeling (BIM)
Communications
If part of a customer’s requirement is a BIM model, then we can supply 3D information (in various electronic file types) upon request. As well as all associated data and technical submissions if required.
This information is invaluable when evaluating space and services within a building design. BIM modelling can also assist in the analysis of areas for cable routing and access to the switchboard.
The S4 switchboard can be configured to communicate with Building Management software. Metering options coupled with dynamic energy control and monitoring ensures your circuits are working at optimum efficiency.
Modbus TCP, Profibus TCP, Profinet and Ethernet possibilities.
The use of modern communication-capable circuit breakers opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects.
• Sentron Surge protection devices available
• Circuit protection in the unlikely event of an overvoltage
• Suitable for TT and TN-S systems
• SPD classification / acc. to EN 61643-11 / Test Class II, Type 2
• Overvoltage category / acc. to IEC 61010-1 III
• kW hours monitoring
• kW demand monitoring
• Amps, Volts monitoring
• Harmonic Distortion monitoring
• Modbus TCP, RTU
• Ethernet and RS 484 comms’ & Profibus, Profinet protocols
• MID approved
9
Sivacon S4 | Low-Voltage Switchboards
10
Low-Voltage Switchboards | Sivacon S4
Notes Standards and regulations Design-verified low-voltage switch-gear and controlgear assembly
IEC 61439-1/2EN 61439-1/2
Key electrical data Rated operational voltage (Ug) Up to 690 VType of current ACRated frequency 50/60 HzRated impulse withstand voltage (?) Up to 12 kVPollution degree 3Material group IIIRated insulation voltage 1000 VRated current Up to 3200 A
Rated peak withstand current Up to 220 kARated short-time withstand current Up to 100 kA, 1
second
Arcing fault testing Main busbar in compliance with IEC 61641
Rated operational voltage 400 VRated short-time alternating current 50 kALength of internal arc 100 msLength of internal arc with barrier 300 ms
Safety class According to IEC 61140, EN 61140 IDegree of protection According to IEC 60529, EN 60529
Ventilated IP3X, IP30, IP31, IP4X, IP40, IP41Non-ventilated IP55
Form of internal separation Form 4a type 2Form 4b type 5Form 4b Type 6 Group-mountedForm 4b Type 6 Compartmentalised
Resistance to impacts According to IEC 62262, Paragraph 9.6Top plate IK09Door, side panel, rear panel IK10
Static loads on enclosure parts Front frame Swivel 1.0 kg
Fixed 5.0 kgCover with quick-closing screws Height 50 – 300 mm 0.5 kg
Height 350 – 550 mm 1.0 kgHeight 600 – 800 mm 2.0 kg
Inner door 2.5 kg
Section door/double door Width 400 – 600 mm 10.0 kg
Width 800 mm 5.0 kg
Width 1000 – 1200 mm 2.5 kgModular door Height 150 – 200 mm 0.5 kg
Height 250 – 350 mm 1.5 kgHeight 400 – 800 mm 3.0 kg
Outer cover 10.0 kgOperating conditionsObserve correction factors for other componentsAmbient temperature 24 hour mean value ≤ 35 °CInstallation altitudes ≤ 2000 mInstallation Indoor installationOperating personnel Electrically skilled personsSteel thickness Frame 2.5 mm
Enclosure 1.5 mmSurface treatmentFrame components and interior components Sendzimir-galvanized Min 20 µmEnclosure parts Epoxy polyester resin RAL 7035 (other colours available on
request)Iron phosphatingTotal thickness of coating Min 70 µm
DimensionsFrame exterior dimensions Height in mm 2000
Width in mm 200, 400, 600, 800, 850, 1000, 1200Depth in mm 400, 600, 800
Hole pattern in frame acc. to DIN 43660 In mm 25Plinth Height in mm 100, 200
Technical specifications overview
11
Sivacon S4 | Low-Voltage Switchboards
12