Superconducting Magnetic Energy StorageConcepts and applications
Antonio MorandiDEI Guglielmo MarconiDep. of Electrical, Electronic andInformation Engineering
University of Bologna, Italy
Tuesday, November 27, 2018
2
• Energy Storage
• SMES TechnologyPower conditioning system & operationSC CoilState of the art
• SMES ApplicationsCustomer / IndustryGrid
Outline
3
The need for electric energy storage / chapter 1 - grid
• Generation / load imbalance is inherent inthe power grid due to random fluctuation of loads
induced by customers variation of generation from
renewables
• Sudden and large generation/loadimbalance can also occur due tocontingency
• Continuous and fast regulation of the generated power and/or loads isrequired for controlling the frequency and stability of the grid.
4
Load diagram
Due to random nature of fluctuations regulating power is cyclic Regulation is a zero energy service
• Prediction is made by the TSO in order toplan the generation so as to satisfy theenergy need
actual
predicted
imbalance
12500
5
Methods/technologies for grid energy management
• Curtailment of renewables• Improved control of convent. gen.• Demand control• Network upgrade ( … Supergrid )• Energy storage
Energy storage system allows to shift electric energy in time so as to decouple productionand consumption
6
The need for electric energy storage / chapter 2 – customer
Energy storage
• Power quality and UPS
• Leveling of impulsive/fluctuating power
(industry, physics, … )
Sensitive customers (semiconductors, oil, data centers …) cannot tolerate power
interruptions or voltage sags
7
Which storage technology?Parameters of the energy storage system
• Absorbed/supplied power, P• Duration delivery, t• Number of cycles, N• Response time, tr
No unique storage technology exists able to span the wide range of characteristicsrequired for applications
• Most suitable storage technology mustbe chosen from case to case
• Hybrid systems, obtained by combiningdifferent storage technologies,represents the best solution in manycases
In many applications the parametersof the operating cycle changescontinuously and randomly.
8
• Energy Storage
• SMES TechnologyPower conditioning system & operationSC CoilState of the art
• SMES ApplicationsCustomer / IndustryGrid
Outline
PCS
Control andprotectionsystem
Coolingsystem
Superconductingcoil
gridCurrent leads
vacuumvessel
9
SMES – Superconducting Magnetic Energy Storage
2
0
2
0
2
2
1
22ILd
Bd
BW
coil
10
• For typical design assumptions for power electronics current of SMES operating in theMW range is in the order of kAs
• More conductors have to be put in parallel for reaching the required transport current
Continuously transposed (Roebel) cable
• Scraps are produced• Je cable = 0.8 – 0.9 Je tape
Magnet design – cable requirement
Conductor on Round Core (CORC) cable
• Je cable > 200 A/mm 2 @ 4.2 K and 20 T
11
5 MJ coil - 4TTorus2G HTS
Magnet design – coil geometry – a study
5 MJ coil - 4TSolenoid2G HTS
• Simpler and more cost effective• Easier handling of the electromagnetic stress• Smaller foot-print
• Low stray field• Reduced perp. field on conductor
Mechanical design includes• Pretensioning due to winding of the coil• Thermal contraction during cool down• Lorentz force
Von Mises stress Strain
Mechanical analysis
204 MPa maxon G10
0,15% maxon cond.
Stress within allowable limitfor all materials
Strain within allowable limitfor all materials
Equivalent Young’s modulus of the tape of 157.3 MPaobtained from weighted average
Elastic’s moduli and thermal expansion coefficients ofall materials taken from• K Konstantopoulou et al., “Electro-mechanical characterization of MgB2
wires for the SC Link Project at CERN”, SUST 2016• J. W. Ekin, Experim. Techniques for Low Temp. Measurements, OUP, 2006• P. Bauer et al., EFDA Material Data Compilation for Supercond. Simulation• CRYOCOMP
Quench Detection&Protection
Temperature distrbution at 1 sT/n=0
T/n=0
T/n=0
=0L = 6.8 HR = 2.1 Ω = 3.3 sHeat
injection
0.2 s
SMES discharged on the dumpresitor by means of the QPS
The appearance of the resistance in onehalf of the coil is detected by means ofbalanced bridge
Discharge of the coil on a dump resistoris commanded if the quench is detected
• The dump resistor must be chosen so as that the voltageon the coil does not exceed the allowed limit
• Thermal analysis must be carried out to calculate the hotspot temperature reached
14
Power conditioning system – black box
SMES
0
PCSAC
Grid
P I
2 20 0
1 1( )
2 2L I LI P t t
Energy balance
I0
SMES current
Delivered/absorbed powerI0, current of SMES at time t0
20 0
2( )I I P t t
L
“−” and “+” apply duringdischarge/charge respectively
Unidirectional current, changing as sqrt of time, is obtained in the SMES duringcharge and discharge
L
15
• Flexible architecture - Control algorithm defined based on the service to be provided• Power modulation• Islanding operation• Active filtering
• Magnet protection system integrated in the PCS both at HD and the SW level
Power Conditioning System - detail
System level control P*, Q*, v*
DC/AC - inverter DC/DC - chopper
16
Discharge (or charge)
L
C
Vdc
ISMES
• Controlled power transferred from the DC bus thegrid by means of the inverter
• The voltage of the DC bus is kept constant by theSMES by means of the two quadrant chopperDC
/ AC
Idc Idc
Vdc constant < I dc > = < Idc > P = P
< I dc >ISMES
time
TON
TOFF
Tcycle
Idc
L
C
Vdc
ISMESDC /
AC
Idc Idc
L
C
Vdc
ISMESDC /
AC
Idc Idc
Similar behavior during charge
Negative voltage on coil ( - Vdc )Current slightly decreasing
Zero voltage on coilCurrent constantTcycle typically 0.1 – 1 ms
(1 – 10 kHz)
17
Ripple• Smooth average current profile during charge or
discharge of the SMES coil• Time change (functional) of the smooth current
profile is responsible for AC loss induced in thecoil (and metallic parts)Example:
1 MW 5 s dischargeLSMES = 1.250 Hfchopper = 500 Hz
A ripple at the same frequency of choppercommutation is superimposed to thesmooth profile
This ripple has negligible amplitude and hassmall effect in terms of AC loss
20 0
2( )I I P t t
L
18
To know on SMES – 1 / Energy capacity
Typical rating of SMES in the order of MJs (MW × seconds)
• Energy: MJs kWs
32 cm
1.2 kWhCommercial Li-battery module
Energy capacity of large SMEScomparable with that of smallbattery systems
• Power: MWs
1 MW Li-battery system(groupnire.com)
Power capacity of SMES comparablewith that of large battery systems
19
To know on SMES – 2 / Standby lossesCurrent of SMES free-wheels through PE switches when no power is delivered/absorbed.Losses are produced during the standby
Von IGBT = 0.5 1.5 VVon DIODE = 0.5 1 V
PIGBT = ISMES Von IGBT
PDIODE = ISMES Von DIODE
Pidling = 1 5 kW / kA
SMES currentdelivered power LC
Vdc
ISMESDC /
AC
SMES
• The whole energy of the SMESis lost in the power electronicswithin a few minutes
• SMES is only suitable forcontinuous operation
20
The use of thermal actuated SC switch foravoiding idling losses is possible in principle butit is unfeasible in practice since switching timebelow 1 ms would be required
LC
Vdc
DC /
AC
Idc Idc
Strong synergy possible with cryo power electronics
Great R&D effort (not publically available) on CPE isin progress for application in spacecraft, ships,aircraft, and datacenters
MTECH Laboratories, LLC
21
To know on SMES – 3 / Efficiency
cs
tPtP
P, deliverable powert , duration of delivery tcycle , duration of the cycle tidle, duration of idling phases , intrinsic efficiency of the storage devicec , efficiency of the convertersPaux , power required for auxiliary servicesPidle , power loss (if any) during idling
cycle
power
energy
idleidlecs
tPtP
tP
aux cycle idle idles c
P tP t
P t P t
High efficiency of SMES achieved in case• High exchanged power• No (or short) stand-by / continuous power
management(additional services can mitigate this)
22
Japan
Germany
EM Laucher
JapanUSA
Japan
Italy
France
GermanyPower modulatorFlicker
Gridcompensation
The state of the art of SMES technology
The DRYSMES4GRID project:• 500 kJ / 200 kW SMES• MgB2 material• Cryogen free cooling
23
The Kameyama SMES
10 MW – 1 s SMES system
24
• TechnologyPower conditioning system & operationSC CoilState of the art
• ApplicationsCustomer / IndustryGrid
• SMES experience at the University of Bologna
Outline
25
To summarize ….
• Energy capacity of SMES is much smaller compared to batteries
• Idling losses in power converters do not allow long term storage
• Cooling power continuously required
Is there room for SMES?
At customer level ?At grid level ?
26
1. Leveling of impulsive/fluctuating loads by SMESPl
oad
• Continuous management of high power makes cooling and idling loss negligible• No battery can be considered due to the prohibitive number of cycles• Advantages brought by SMES can be significant also for moderate size systems
• AC loss may be a limiting factor
Pgrid Pload
Sizing of the supply system based on average ratherthan peak power
27
2. Hybrid SMES - Battery systems
Complementary characteristics exploited
• Battery provides long term basepower – hence energy
• SMES provides peak power andfast cycling
Advantages:
• Reduced power rating of batteries• Reduced wear and tear of batteries
(no minor cycling)• Reduced energy rating of SMES
Qualitative (not a real case)
28
3. Combined use with synergistic technologies
A 350kW/2.5MWh Liquid Air Energy Storage (LAES)pilot plant was completed and tied to grid during2011-2014 in England.
Fundraising for further development is in progress
• LAES is used as energy intensive storage• Large cooling power (not all) is available for SMES
due to the presence of Liquid air at 70 K• SMES is used as power intensive storage
Effective hybrid (Energy intensive +Power intensive) storage can beconceived based on combined useof SMES and LAES
A 1-2 MW – 5 min ratingmay be of interest
29
• TechnologyPower conditioning system & operationSC CoilState of the art
• ApplicationsCustomer / IndustryGrid
• SMES experience at the University of Bologna
Outline
30
1. A 200 kJ Nb-Ti µSMES ( 2000 – 2004 )
Cold test in 2004 (and 2013)
31
2. Conduction cooled MgB2 SMES demonstrator (2014 – 2016)
• 3 kJ MgB2 Magnet• 40 KW Mosfet Based PCS
Cold test completedFull test at 1-10 kW to come shortly
32
• Transmission and distribution• Dispersed generation, active networks and storage• Renewables (PV and Biomass )• Energy efficiency in the civil, industry and tertiary sectors• Exploitation of Solar and ambient heat for air conditioning
MISE - Italian Ministry of Economic DevelopmentCompetitive call: research project for electric power grid
The DRYSMES4GRID Project
Partners• University of Bologna• ICAS - The Italian Consortium for ASC, Frascati (Rome)• RSE S.p.A - Ricerca sul Sistema Energetico, Milan• CNR – SPIN, Genoa
Project DRYSMES4GRID funded
• Budget: 2.7 M€• Time: June 2017 – June 2020
Project Coordinator:• Columbus Superconductors SpA, Genova, Italy
• developm. of dry-cooled SMES based on MgB2• 300 kJ – 100 kW / full system
33
Project Workplan
WP2. Layout and functionsWP3. Detailed design and manufact. of converters
Power conditioning system
WP1. Electromagnetic & thermal design
Design of the magnet
WP4. Optimization of in-field perform. of the wireWP5. Manufacturing of wire, cable and winding
Wire, cable and winding
WP6. Assembly of coil and cooling & prelim. testWP7. Assembly of PCS & Experiments in test facility
Assembling and test
WP8
. Diss
emin
atio
n
WP9
. Pro
ject
man
agem
ent
WP1
0.Te
ch.&
Econ
.ana
lys.
of S