TD24 N1&N2 RF Check
After High Power TestMeasurement Date: 09-10.03.2020
Matteo Volpi, Rolf Wegner, Hikmet Bursali
RF Measurement Setup
𝐶𝑜𝑚𝑏𝑖𝑛𝑒𝑑 𝑅𝑒𝑓𝑙𝑒𝑐𝑡𝑖𝑜𝑛 =1
2(𝑆11 + 𝑆13 + 𝑆31 + 𝑆33)
11.9917 GHz 11.9932 GHz 11.9916 GHz 11.9965 GHz
+1.5 MHz shift +4.9 MHz shift
𝐶𝑜𝑚𝑏𝑖𝑛𝑒𝑑 𝑅𝑒𝑓𝑙𝑒𝑐𝑡𝑖𝑜𝑛 =1
2(𝑆11 + 𝑆13 + 𝑆31 + 𝑆33)
TD24 N1 After High Power TestTD24 N1 Before High Power Test
(From Rolf’s Report)
TD24 N2 Before High Power Test TD24 N2 After High Power Test
(From Rolf’s Report)
TD24 N1 Before High Power Test TD24 N1 After High Power Test
(From Rolf’s Report)
TD24 N2 Before High Power Test TD24 N2 After High Power Test
(From Rolf’s Report)