Technical
Report
No. SAMPLE REPORT
6/11/2019
CUSTOMER
COMPANY
Analyst: Lorenzo Magnoli
Supervisor: Roberto Lavelli
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
2
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
Aim of the Analysis:
Verify soldering process conformity according to IPC-A-610 G and ageing effects on
solder alloy
Performed test:
1. XRAY analysis
2. Cross section according to IPC TM 650 2.1.1 manual method and inspection
according to IPC-A-610G
3. TOTAL IONIC CONTAMINATION according to IPC-TM-650 par. 2.3.25
4. Accelerated Ageing according to IPC-SM-785
Category Industrial
-20/+80 °C cycles – dwell time 15 min – 365 cycles per year simulated
3 years simulated
Material Received:
1. 4 PCBA samples with S/N:
a. 14191119000001
b. 14191119000004
c. 14191119000007
d. 14191119000008
Equipment Used:
1. Aqueous ZERO ION
2. LEICA DM6000 metallographic microscope
3. XRAY NORDSON DAGE QUARDA 7
4. WEISS Shockevent T300
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
3
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
Results:
1. XRAY AND VISUAL ANALYSIS
SAMPLE RESULTS
14191119000001 PASS
14191119000004 PASS
14191119000007 PASS
14191119000008 PASS
2. CROSS SECTION ANALYSIS
SAMPLE RESULTS
QFP CAPACITOR CONNECTOR
SMD PASS PASS -
PTH - - PASS
3. TOTAL IONIC CONTAMINATION
SAMPLE RESULTS
SMD PASS 0.01 µg/cm2
SMD + PTH PASS 0.03 µg/cm2
4. CROSS SECTION ANALYSIS AFTER AGEING
SAMPLE RESULTS
QFP CAPACITOR CONNECTOR
SMD FAIL PASS -
PTH - - PASS
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
4
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
1. VISUAL INSPECTION ANALYSIS
TOP SIDE
BOTTOM SIDE
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
5
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
2. XRAY ANALYSIS
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
6
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
3. CROSS SECTION ANALYSIS
SMD
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
7
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
PTH
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
8
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
4. TOTAL IONIC CONTAMINATION
SMD ONLY
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
9
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
SMD + PTH
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
10
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
5. CROSS SECTION ANALYSIS AFTER AGEING
SMD
CRACK
Customer: COMPANY Date: 06/05/2019 No. Report: SAMPLE REPORT
11
PREVENT DIGITAL-LAB S.R.L. Via Sempione, 26, 21029, Vergiate (VA)
PTH