*See following page (e.g., dry eye vicious cycle of inflammation)
Think Outside the Eye
Do your patients suffer from dry, itchy, red or burning eyes?Dry Eye Disease (DED) is the most common condition seen by eye care professionals The disease has a significant impact on quality of life, with symptoms such as foreign body sensation, pain, blurry vision, dryness or watery eyes. Meibomian gland dysfunction (MGD) is a multifaceted disease, known to be the leading cause of DED in more than 85% percent of patients.1
DED can have a significant influence on patients’ satisfaction with ophthalmic surgeries · Ophthalmic procedures can trigger DED or aggravate existing DED2,3
· Ophthalmic procedures in patients with pre-op DED results in less favorable outcomes4
First-of-its-kind, drug-free, drop-free, light-based treatmentUnlike conventional treatments that work within the eye, Optima IPL uses advanced technology to deliver a controlled amount of intense pulsed light around the eye.
With every pulse of light, this first-of-its-kind, energy-based therapy works to control the inflammatory process and to stop the vicious cycle of dry eye due to MGD* - displacing the need for medications and providing long-lasting results.
Epidermis
Dermis
Hypodermis
Break the dry eyevicious cycle
ASIA / PACIFICBeijing, ChinaTel +86 10 5737 6677Gurgaon, IndiaTel +91 124 422 07 95Kowloon, Hong KongTel +852 217 428 00Fax +852 272 251 51
System SpecificationsDimensions[without ResurFX]
44 x 51 x 47 cm(17 x 20 x 19 inches)
Dimensions[with ResurFX]
44 x 51 x 62 cm(17 X 20 X 24 inches)
Weight[without ResurFX]
40 kg / 88 lbs
Weight[with ResurFX]
55 kg / 121 lbs
Electricalrequirements
100 – 240 VAC, 12A max., 50/60 Hz, single phase, dedicated line
Universal IPLSpectrum 400-1200 nm
ExpertFilters Acne (400 nm-600 nm & 800 nm-1200 nm); 515 nm;Vascular (530 nm-650 nm & 900 nm-1200 nm); 560 nm; 590 nm; 615 nm; 640 nm; 695 nm; 755 nm
Lightguides 15 x 35 mm; 8 x 15 mm, 6 mm Ø
Fluence Up to 35 J/cm2 for rectangular lightguides;Up to 56 J/cm2 for the round lightguide
Pulse Duration 4-20 ms
Pulse Delay 5-150 ms
Pulse Characteristic Multiple Sequential Pulsing
Repetition Rate Up to 1 Hz
Cooling Continuous contact cooling
© 2018 All Rights Reserved. The Lumenis Group of Companies.PB-2005802 Rev. C. Lumenis, its logo, M22, OPT, Multiple-Sequential Pulsing, ExpertFilters, SapphireCool lightguides, ResurFX and CoolScan are trademarks or registered trademarks of the Lumenis Group of Companies. Specifications are subject to change without notice Lumenis is ISO 13485:2012 certified. M22 is CE approved. | M22 is FDA cleared.
The indications are only relevant where they were approved by the Regulatory Authorities. The Dry eye indication has not been cleared in the United States by the FDA.
w w w. l u m e n i s .c o m /O p h t h a l m o l o g y
Technical Parameters of Optima IPL
AMERICASSan Jose, CA, USATel +1 408 764 3000 +1 877 586 3647Fax +1 408 764 3999
EMEADreieich Dreieichenhain,GermanyTel +49 6103 8335 0Fax +49 6103 8335 300Roma (RM), ItalyTel +39 06 90 75 230Fax +39 06 90 75 269Hertfordshire, UKTel +44 20 8736 4110Fax +44 20 8736 4119
JAPANTokyo, JapanTel +81 3 4431 8300Fax +81 3 4431 8301
Lumenis Ltd.Yokneam Industrial ParkHakidma Street 6, P.O.B. # 240Yokneam 2069204, ISRAELTel +972 4 959 9000
Lumenis Ltd. Lumenis (Germany) GmbHHeinrich-Hertz-Str 3 D-63303Dreieich-Dreieichenhain GERMANYTel +49 (0) 6103 8335 0
0483
Rx ONLY
Risks and warning (non-inclusive list): Optima IPL is contraindicated for patients with active infections, dysplatic nevi, or tattoos in the treatment area. Optima IPL can cause epidermal injury, including redness, swelling, scarring, change of pigmentation, blisters, break in skin integrity, and sloughing. Risk of epidermal injury increases with greater fluence, shorter delays, shorter pulse durations, darker skin pigmentation, thin skin, and exposure to the sun within one month following treatment. Refer to the operator manual for a complete list of intended use, contraindications and risks.
1. Lemp et al. (2012) Cornea 31(5): 472-8; 2. De Paiva et al. (2006) Am J Ophthalmol 141(3):438-45; 3. Solomon et al. (2004) Ocul Surf 2(1):34-44; 4. Shtein (2011) Expert Rev Ophthalmol 6(5):575-82; 5. Viso et al. (2014) Eur Ophthalmol Rev 8(1):13-6.; 6. Kassir et al. (2011) J Cosmet Laser Ther 13(5):216-22; 7. Papageorgiou et al. (2008) Br J Dermatol 159(3):628-32; 8. Liu et al. (2017) Am J Ophthalmol 183:81-90.; 9. Yin et al. (2018) Curr Eye Res 43(3):308-13; 10. Toyos & Briscoe (2016) J Clin Exp Ophthalmol. 7(6); 11. Dell et al. (2017) Clin Ophthalmol 11:817-827; 12. Prieto et al. (2002) Lasers Surg Med 30(2):82-5.
Rosacea5,6
Triggers Demodex /Bacterial Load
RefractiveSurgery
DysfunctionalMeibomian
Glands
OcularSurfaceInflammation
UnstableTear Film
Lifestyle
EyelidInflammation
AbnormalBlood
Vessels
Break the dry eye vicious cycle
· Destroys the abnormal blood vessels that are perpetuating the inflammation6,7
· Decreases the level of pro-inflammatory mediators and inhibits the progression of the inflammation8,9
· Reduces the tear film osmolarity back to normal levels10,11
· Restores meibomian gland’s morphology and functionality9
· Decreases Demodex mites stimulating infection leading to MGD12
Optima IPL breaks the vicious cycle of inflammationand restores homeostasis in DED due to MGD10,11
“I’ve been using IPL to treat MGD for 18 years. Now with Lumenis’ new Optimal Pulsed technology (OPTTM) that provides consistent energy level, with no spikes in energy, I can reach top success rate with my MGD patients. In addition, recent studies, done by myself and others, show that Optima IPL reduces the inflammation which is a key contributor to MGD and Dry Eye”
Rolando Toyos, MD
DED due to MGD cycle of inflammationTreat the signs and symptoms of MGDIPL improves signs and symptoms of DED due to MGD11.
“Optima IPL is an important addition to my practice as it allows me to offer my patients a drug free, drop free treatment and to reach a significant improvement in signs and symptoms of DED due to MGD in just few short treatments”.
Laura M. Periman, MD
+91.3% improvement in tear break up time
DED MGD treatment Rosacea treatment
54.7% decrease in dry eye symptoms
BL
+91.3
FU1 FU2 FU3
Tear
Bre
ak-u
p T
ime
(sec
)
0
2
5.8
4
6
8
10
12
9.39.6
11.2
BL
-54.7%
FU1 FU2 FU3
SP
ED
D S
core
0
2
5.94
6
8
10
12
14
9.3
6.46.6
12.9
Baseline
After 4 months
After 6 months
Courtesy of Rob Noecker, MDCourtesy of Laura M. Periman, MD
After 2 IPL treatments
After 2 IPL treatments
Before
Before
Lumenis, the inventor of IPL, is proud to present Optimal Pulse Technology (OPT™)
Homogenous pulses· No spikes in energy· The energy you choose is the energy you get
Safety
Reproducible pulses· Consistent level of energy between pulses
Ef�cacy
· Optima IPL is a modular system, allowing to extend your practice to additional 20 different skin indications and aesthetic treatments (e.g., vascular lesions)
· ExpertFilters™ tailored to the skin type, indication, and severity for optimized results
Modular system that includes additional skin conditions and aesthetic treatments
SapphireCool™ chiller tip allows to:
1. Reach higher levels of energy and achieve optimal results 2. Provide safe and comfortable treatment for the patient
Patented water cooled tip
T1
Spike
T2 T3 T1
T1 = T2 = T3
Constant Energy
T2 T3
Other IPL systems
T1
Spike
T2 T3 T1
T1 = T2 = T3
Constant Energy
T2 T3
Lumenis IPL with OPT™