The TP8-28 and TP8-28 GSM systems implement the
Tecnoalarm RSC technology right from the basic versions.
The advantages and the performance offered by the RSC
technology are now available to realize even small-sized
installations with a high level of technology.
Expandable serial alarm systems
TP8-28 – TP8-28 GSM
Zone
Configuration
System
Configuration
8
Programs
1 2 3 4 5Finger
100Acces Period
4
Key
100Yearly Calendar
2
Trasmitter
80Timer
6
Code
120
OPERATINGCODES
AUTOMATICFUNCTIONS
Wired
28
Wireless
28
Logic
Zones28
Tecnoalarm Technology
ZonesSystem configuration is entirely modular thanks to the input expansion modules.The 2 conventional and the 6 bus inputs of the CPU constitute the basic version ofthe system. They are expandable to a total of 28 zones which can be freely associatedto the hard-wired (conventional or bus) or wireless inputs of the connected hardware.The zone programming facilities allow to obtain excellent performances even fromtraditional detectors but the best results are obtained by using the Tecnoalarm RDVand RSC detectors. These detectors permit the verification and analysis of the alarmsat the very moment they are released, through the specific diagnostic tools of themonitoring software. In this way, the limitations of traditional remote managementhave been overcome and a new concept of interaction has been proposed.(RDV® and RSC® are registered trademarks and protected by international patents)
The Tecnoalarm systems which are equipped with the(Remote Sensitivity Control) technology communicate withthe monitoring station and transmit specific and detailedinformation. The Tecnoalarm monitoring station can programand constantly monitor the system from a distance and, usingsophisticated diagnostic tools, verify the smooth functioningand obtain the necessary information to maintain and improveits performance.
ProgrammingProgramming of the system’s functioning parameters can be madelocally or remotely, via telephone line, using the Tecnoalarm software.The software provides numerous programming tools which permitcustomization of the installation selecting the most appropriate amongthe options available.
Programs and control unitsThe TP8-28 and TP8-28 GSM systems manage 8 programs. A wide range of controlunits is able to satisfy any application requirements. The range comprises theLCD300/S console with voice synthesis, the new LCDPROX1 console with graphicdisplay and transponder reader, RFID card and finger print readers as well as theexclusive TSP7000 STD consoles with 7 inches touch screen and, for the STD-BIOversion, with biometric finger print reader. The users have access to the system’sfunctions through 120 codes, 100 transponders/RFID cards, 80 wireless keys and100 finger prints. Access to the protected areas can be automated and regulatedby 4 access periods and 6 timers.
TelephoneCommunication
Wireless
Controls
Remote
Advanced
Configuration
Data File
Events
Alarm
Photo
dBm level
RF Monitor
LowHigh
Bad
Timers
64
Actions
128
Phone Book
6
Counters
16
Synoptic
4
SMS DTMF
Lights Shutters
Roller
Irrigation
8 RemoteControl
VOICE RINGSMS DTMFFSK DATI
PSTNInterface
TP8-28 SYSTEMCOMMUNICATION
DEVICE
TP8-28 GSM SYSTEMCOMMUNICATION
DEVICE
156 PROTOCOLS
GSM-GPRSModule
Ethernet59 PROTOCOLS
GSM-GPRSModule
Ethernet
Event BufferCapacity
1500
Download SavePrint
Consoles
2Sirens
2Sensor
28
WIRELESSDEVICES
Event logThe event log contains all the events relating to the system’s functioning, i.e.the alarms, the diagnostics and the changes of status. A total of 1500 eventscan be recorded, in reverse chronological order, with indication of date and time. For each event, detailed information is given about the interested zones,programs and remote controls, identified by a number and a description,as well as the telephone calls. For each alarm detected by the RSC detectorsa graph showing the detector’s functioning at the moment of alarm releaseis also stored. The installer can download the event log at any time using theTecnoalarm software and extract the necessary information to verify thesystem’s smooth functioning.
Advanced programmingThe advanced programming tool is a software expansion of the programmingfacilities of the TP8-28 and TP8-28 GSM systems permitting a large extent ofcustomization extending the system’s resources and integrating homeautomation functions. It allows to offer functional solutions to particularapplication requirements making cost-expensive external devices redundantand implementing the PLC (programmable logic controller) programming logic.The conventional functionality of the inputs, outputs, channels, remote controlsetc. is redefined through a series of actions, associated to the events.The actions can be linked and scheduled by timers and counters.
Telephone sectionThe telephone section provides 8 telephone channels. The TP8-28 system uses thePSTN line and optionally the GSM or Ethernet network through respectively the externalGSM communicator TECNOCELL-PRO PL and the PROG NET2 Ethernet interface.The TP8-28 GSM system uses the GSM network through the integrated GSM/GPRSinterface or the external GSM communicator TECNOCELL PRO-PL and optionally theEthernet network through the PROG NET2 Ethernet interface. According to the system,TP8-28 or TP8-28 GSM and the vector, the telephone section uses several communicationformats: voice calls, SMS or data transmission in FSK, DTMF and TCP/IP formats.The alarm and system status messages are automatically composed by the systemusing the onboard vocabulary. The TP8-28 and TP8-28 GSM systems communicate withthe user and the central monitoring stations using respectively 156 and 59 communicationprotocols.
Wireless sectionThe expansion of the system is possible, even if cable laying is complicated,by the installation of maximum 2 wireless receivers or receiver-transmittersable to manage a total of 80 wireless keys, 28 wireless detectors as well as,respectively, 2 wireless consoles and sirens. The wireless communication,i.e. the transmissions of the alarm signal and the automatic test signal (supervision),is constantly verified and analyzed and the detected interferences, transformedinto a graph, can be consulted, locally or remotely, using the RF Monitor diagnostictool of the Tecnoalarm software. The wide range of Tecnoalarm wireless detectors,comprising indoor and outdoor detectors as well as perimeter protections, offersideal solutions for all protection requirements.
InteractionThe TP8-28 and TP8-28 GSM systems provide 8 remote controls whichallow the user to interact with the systems through telephone calls orSMS messages. The remote controls are customizable and permit the management of the system’s functions as well as the interaction with external devices such as heating, air-conditioning, lighting equipment etc.
SENSOR BUS
PROG USB PROG NET2 TSP LINK
ETHERNET
TSP7000 STD-BIOTSP7000 STD
SRA
SRINT
OUT2 OUT2
OUT1 OUT1 OUT1
SIREN BUS
SPEED ALM8 PLUS SPEED 8 PLUS SPEED 4 PLUS SPEED ALM8 PL
SAEL 2010 BUS
TP SDNTECNOCELL-PRO PL ESP32-OCNSINOTTICO 32N
+ SRA
- SIR
- OUT1
- OUT2
APR CARD APR FINGER APR FINGER-CARD
SRA
SRINT
OUT2
OUT1
OUT2
OUT1 OUT1
SPEED 8 SPEED 4 SPEED 8 STD
RX300/433868 RTX200/433868
SIREN BUS
LCD300/S LCDPROX1 SERIAL BUS
ESP4-20 TP PROX
Mar 10 GEN 12Feri. 13:46
4
8
3
7
2
6
1
5
6 DEVICES
2 DEVICES
8 DEVICES
2 DEVICES
1 DEVICE 12 DEVICES
TP8-28 – TP8-28 GSM SYSTEM CONFIGURATION
8 DEVICES
1 DEVICE
28 DEVICES
2 DEVICES
2 DEVICES
2 DEVICES
PROG INTERFACE
RSC DETECTORS
Mar 10 GEN 12Feri. 13:46
4
8
3
7
2
6
1
5
TP OUT6OCV+ -
SRE-
SRI- OUT
1 2 3 4
TP PROXLED V+L1 L2 L3 KR1L4 KR0
TP OUTRELC NO NC
TP BUSVOC+ - A B S
ESP BUSTP BUS+ - A B
SPEED ALM8 PLUS SPEED 8 PLUS SPEED 4 PLUS SPEED 8 SPEED 4
POWER SUPPLY 1.8A 1.8A
ZONES 8 BUS 8 BUS 4 + 4 BUS 8 8 4
OUTPUTS 4 2 1 4 2 1
CASING optional optional optional optional
CODE F101SPEALM8PLUS F101SPEED8PLUS F101SPEED4PLUS F101SPEEDALM8PL F101SPEED8 F101SPEED4
Input
expansions
TECHNICAL SPECIFICATIONS OF BUS EXPANSIONS
4 2 1
1 SIREN BUS
SPEED ALM8 PL
ESP32-OCN SINOTTICO 32N
OUTPUTS
32 programmable
LEDSIGNALING LED
CASING optional
32 programmable
open collectors
CODE F127ESP32OCN F127SINOTTICON
Output
expansions
TSP7000 STD TSP7000 STD-BIO
FINGER PRINTS
MEMORY local (100 finger prints)
CODES
PROGRAMS 8 8
VOICE SYNTHESIS
LCD 7” 65,000 colors – touch screen – 800x480dpi
ETHERNET PORT
USB PORT
RS422 SERIAL PORT
CODE F210TSP7000ST F210TSP7000STBI
Touch screen
consoles
LCD300/S LCDPROX1
CODES
TRANSPONDERS
PROGRAMS
DISPLAY
8 8
VOICE SYNTHESIS
SIGNALING LED
CODE
LCD
consoles
2x16 characters
36 23
F127LCD300S F127LCDPROX1
graphic
N.B. Connection with the control panel through TSP LINK
SAEL 2010 BUS SAEL 2010PRO BUS
PROGRAMS 1 to 8 1 to 8
ANTI-DRILLING
ALARM MODES 16 16
CASING ABS aluminum
ANTI-FOAM
CODE F105S2010BUSBI F105S2010PROBUS
Bus
sirens
SENSOR BUS
ZONE BUS
FINGER PRINTS
RFID CARDS
CODES
MEMORY local (100 finger prints) local (100 finger prints)
PROGRAMS 3 3 3 4
SIGNALING LED 4 4 4 7
Secondary
control
units
APR FINGER APR CARD TP SDNAPR FINGER-CARD
CODE F103APRFINGCARD F103APRFING F103APRCARD F127TPSDN
TP BUS TP BUSVOC
Additional
modules
COMPATIBILITY
FUNCTION
VOICE SYNTHESIS
For TP8-28 and TP8-28 EN only
CODE F127TPBUS F127TPBUSVOC
serial bus serial bus
ESP4-20
ZONES 4
CODE F127TP420ESP
Internal
input expansion
TP PROX TP OUT6OC
Additional
modules
COMPATIBILITY
FUNCTIONOutput expansion6 open collectors
Relay module1 relay
TP OUTREL
All versions
Technical specifications of internal expansions
RTX200/433868 RX300/433868
RECEIVER
RECEIVER-TRANSMITTER
RX FREQUENCY 433MHz/868MHz 433MHz/868MHz
TX FREQUENCY 868MHz
CODE F102RTX200 F102RX300
CASING
Wireless
expansions
SPEED 8 STD
8
optional
F101SPEED8STD
TECNOCELL-PRO PL
FUNCTION
PROTOCOLS
VOICE MESSAGES
BACKUP
SMS MESSAGES
CODE F104TECNOC/PPL
GSM
CODE F127TPPROX F127TPOUT6OC F127TPOUTREL
Transponderinterface
secondary/backup
ZONE BUS
Interface
PSTN Advanced
Configuration
Power
A V
Supply Box
ABS
Module
GSM
EN 50131-1EN 50131-3
Approval
ConnexionSerial BUS
Connexion
Serial BUS
VOC
c/Vapor 18 (Pol. Ind. El Regas)08850 Gavá - Barcelona (España)tel. [email protected] - www.tecnoalarm.es
495, Rue Antoine Pinay - 69740 Genas - Lyon (France)tél. +33478406525 - fax [email protected] - www.tecnoalarm.comAgence de Paris: 125, Rue Louis Roche - 92230 Gennevilliers
Via Ciriè, 38 - 10099 San Mauro T.se - Torino (Italy)tel. +390112235410 - fax [email protected]
11-2
011
Rev
. 0
CONTROL PANEL VERSIONS
For the itemnumbers please
contact thereseller
TP8-28
TP8-28 EN
TP8-28 GSM/V EN
TP8-28 GSM/V
2A
2A
2A
2A
All specifications listed in this brochure are subect to change without notice.
Optional
Optional
Optional
Optional
Grade 2
Grade 2
ZONES
SYSTEM
FEATURES
OUTPUTS
PROGRAMS
ACCESS
MANAGEMENT
AUTOMATION
TELEPHONE
SECTION
TP8-28
Total logic zones
CPU hard-wired zones
Total hard-wired zones
Total wireless zones
28
2 conventional + 6 bus
28
28
Actions
Timers
Counters
Telephone directory
Reserved output expansions
128
64
16
6
4
Operating voltage
CPU board consumption TP8-28
CPU board consumption TP8-28 GSM
Power supply
Battery
230V AC +/- 10% 50Hz
150mA @ 13.8V DC
220mA @ 13.8V DC
2A @ 14.8V DC
12V/7Ah
Casing
Dimensions (L x H x D)
Weight (without battery)
ABS
350 x 285 x 93mm
TP8-28 (2.7kg) - TP8-28 GSM (2.8kg)
CPU outputs
Logic siren outputs
2 + 2 programmable
4
RS485 serial bus
Voice synthesis
Event buffer capacity
Printer management
According to version
According to version
1500
Programs
Access codes
Finger prints
Transponders/RFID
Wireless keys
8
120
100
100
80
Timers
Access periods
Calendar years
Remote controls
Test call
Server test call
6
4
2
8
Hard-wired input expansions
Wireless expansions
Consoles
Secondary control units
Output expansions
GSM telephone communicator
Bus sirens
Wireless sirens
Wireless consoles
2
2
8
8
12
1
2
2
2
ADVANCED
PROGRAMMING
ELECTRICAL
SPECIFICATIONS
PHYSICAL
SPECIFICATIONS
Channels
Primary vector
Secondary vector (optional)
Secondary vector (optional)
Transmittable events
Telephone number length
Call event queue
Communication protocols
8
PSTN
External GSM
Ethernet
128
24 digits
32
156
SERIAL BUS
EXPANSIONS
TECHNICAL AND FUNCTIONAL SPECIFICATIONS
TELEPHONE
SECTION
TP8-28 GSM
Channels
Primary vector
Secondary vector (optional)
Secondary vector (optional)
Transmittable events
Telephone number length
Call event queue
Communication protocols
8
GSM
External GSM
Ethernet
128
24 digits
32
59
Optional
Optional
Optional
Optional