1
The Name You’ve Trusted for Years …..
TESTING & APPROVALS
2
Worldwide Leader in Firestop Technology - Our Family Of UL approved Metacaulk® Firestopping
Products is specifically designed to fill voids in construction joints and around penetrations in fire-rated
walls or floors. Many have intumescent properties and expand when exposed to heat, forming a high-
strength insulating char. Metacaulk® products contain a combination of biocides that protect the
product in both the cured and non-cured state against mold growth. Our intumecent firestop products
comply with required environmental exposure testing of accelerated aging and high humidity, as per UL
1479 Fire Test of Trough-Penetration Firestops. In the event of fire, sealant will restrict the spread of
flames, smoke, hot gases and water. Whatever your application, we provide the most cost effective
products to fit your every need.
A computerized control room monitors all phases of test burns as specified by
ASTM E-814 (UL 1479) or ASTM E-1966 (UL 2079).
Two on-site test ovens allow for quicker response to customer needs for UL
approved system and speed the development of new system.
After test burns, assemblies are immediately subjected to a hose stream test
to complete the ASTM E-814 (UL 1479) or ASTM E-1966 (UL 2079) procedure.
3
COMPANY PROFILE
RectorSeal, founded in 1937, is a leading
manufacturer of firestopping products. In
1995, an on-site fire test laboratory was
built for the purpose of conducting UL
witnessed burns for trough-penetration
and construction joint assemblies. Our
laboratory has been designated by UL
under their Witness Test Data Program for
fire testing to UL 1479 & UL 2079.
4
berkonsentrasi dalam bidang “Fire
Stopping Product”, merupakan agen
penjualan di wilayah indonesia dandipercayakan untuk penerapan produk Metacaulk® yang telah dan masih digunakan oleh Industri ataupun Gedung di Indonesia dan seluruh dunia, Kami didukung oleh tenaga profesional yang sudah berpengalaman dibidangnya dengan tujuan untuk dapat memberikan pelayanan terbaik sesuai kebutuhan
perusahaan anda. Berdasarkan pengalaman, kami dapat memberikan konsultasi
dan estimasi biaya untuk memberikan solusi terbaik dan tepat guna untuk perusahaan anda.
PT. TRINITAS VICTORI PYROGEN NUSANTARA merupakan agen produk Metacaulk®
Metacaulk® adalah produk Penyekat Api yang diaplikasikan pada kabel - kabel di panel listrik atau
shaft cable tray antar ruangan atau antar lantai gedung dan genset sebagai Proteksi Pasif, berfungsi
juga sebagai Kompartemen Pemisah dan Penutup pada bukaan antar ruangan atau lantai. Sangat
membantu untuk megatasi Penyebaran Api atau Melokalisir Api dan mencegah kerusakan kabel yang
disebabkan oleh serangga dan air. Semua produk kami telah diuji dan terakreditasi oleh pihak Dinas
Pemadam Kebakaran dan dinyatakan Memenuhi Syarat serta laik pakai sebagai bahan Firestop sesuai
pengujian standard SNI dan ASTM.
5
FIRESTOPPING RECOMMENDATIONS
FIRESTOPPING DECISION PATH :
6
FIRESTOPPING DECISION PATH :
7
Metacaulk® Fire-Rated Mortar has load
bearing characteristics and is suitable for
economically firestopping large openings for
through-penetrations in fire-rated walls and
floors . It can be used with power cables, fiber
optic or telephone cables, alumunium or steel
cable trays, EMT, copper, steel or cast iron
pipe.
p
8
Metacaulk® 1000 is a water-based, flexible, highly
intumescent sealant designed for use on metal,
insulated, fiberglass and plastic pipes. It can also be
used for top of the wall constructions joints, as well
as power and telephone cables. STC rating 54,
Tested in a UL 411 wall assembly / section to ASTM
E90.
Metacaulk® 1000 will prevent the spread of flames, smoke, hot gases and water through joint
openings and through-penetrations. No dilution or mixing is required for use. No special skills
are necessary for installation. Metacaulk® 1000 has passed ASTM E 1966/ UL 2079 for top of
the wall applications with or with out backing and as little as ¼ inch depth of caulk. The test
assembly was also subjected to 500 cycles on a specially built machine that successfully
demonstrated the product’s durability and movement characteristics. 4½
* FGG/BM/CZ™ System Compatible indicates that this product has been tested, and is monitored on an ongoing basis, to assure its chemical
compatibility with FlowGuard Gold®, BlazeMaster® and Corzan® pipe and fittings.
9
Metacaulk ® Putty Sticks are used to seal around penetrating items
through fire-rated walls, floors and within blank openings. For use
with electrical cables, conduit and metals pipes. Hand moldable
with no curing time required. Will not dry out and can be re-used as
additional penetrating item are removed or installed.
Metacaulk® Putty Pads are used to maintain the hourly rating of
fire-rated walls containing electrical outlet boxes and to reduce
sound transmission. Only one pad thickness (1/8 inch) is required
for a 1 or 2 hour fire rating. No additional putty material needed to
plug the end of each electrical metallic tube or conduit at its
connection to the box. Hand moldable with no curing time
required. STC rating 49, Tested in a UL 411 wall assembly/section to
ASTM E90.
10
Metacaulk® Firestop Pillows are intumescent and designed for
use primarily in large temporary or frequently accessed openings
with cables, cable trays, blank openings or multiple penetrating
items. In the event of a fire, Metacaulk® Firestop Pillows will
prevent the spread of flames and hot gases through the openings.
Metacaulk® Composite Sheet is a rigid, fire resistive panel
used to seal penetrations and restore the fire-rating to floors,
ceilings or walls in which a large opening has been made for
the passage of penetrating items. It s made of a reinforced,
highly intumescent material which is bonded on one side to a
galvanized steel sheet.
11
Metacaulk® Cable Coating is a heavy duty, acrylic latex
based intumescent coating used to prevent flame spread
on power and communication cables. Industiral Cable
Coating is designed to resist the spread of fire along the
cable jacketing and to extended the circuit integrity of
the electrical cables during a fire. It has a low odor, and is
compatible with adheres to typical cable jacketing
materials. It can be used for both indoor and outdor
applications, applied using a paintbrush or a airless spray equipment and able to be easily
applied to both vertical and horizontal surfaces.
Metacaulk® Pipe Collars are
prefabricated firestop systems for
through-penetrations using PVC, CPVC,
ABS, PVC foam core, ABS foam core, FRPP, PEX pipe and electrical cable. UL classified for both
open and closed pipe systems. Simple installation. The collar’s design greatly reduces the time
and expense required to install competitive collars.
CABLE COATINGCABLE COATINGCABLE COATINGCABLE COATING
12
TECHNICAL APPLICATION
Metacaulk® Fire-Rated Mortar
HORIZONTAL APPLICATION
VERTICAL APPLICATION
13
Metacaulk® Cable Coating
Metacaulk® Composite Sheet
Metacaulk® Firestop System
14
TESTING MATERIAL
Metacaulk® Mortar diuji coba menggunakan
burner. Pada sisi contact point api, terlihat suhu
555°C. Dengan ketebalan 12cm Metacaulk®
Mortar mampu menahan api atau melokalisir
api, sehingga api tidak menjalar ke sisi lainnya
dan suhu pada sisi tersebut hanya 40°C.
Metacaulk® Cable Coating diuji coba
menggunakan burner. Setelah burner
dipadamkan, api pada kabel berangsur padam
dalam waktu singkat, terjadi kerusakan hanya
pada jacket kabel luar saja. Terbukti
Metacaulk® Cable Coating dapat melindungi
kabel dan menahan rambatan api.
Metacaulk® Cable Coating diuji coba dengan
cara meletakkan kabel yang sudah
diaplikasikan Metacaulk® Cable Coating di
atas tungku api.
Setelah api dipadamkan, terbukti
Metacaulk® Cable Coating dapat menahan
rambatan api atau tidak ada rambatan
lanjutan pada kabel yang terbakar, asap yang
dihasilkan akibat pembakaran juga lebih
sedikit.
15
FIRE INDEX 1. API
• Suatu masa Zat gas yang timbul karena adanya reaksi yang bersifat exotermis (menghasilkan
panas ) dan diikuti oleh pengeluaran cahaya dan panas, serta sisa pembakaran/hasil reaksi yang
berbentuk asap dan arang.
2. PEMBAKARAN
• Reaksi Oksidasi (reaksi kimia antara bahan/benda dengan oksigen O2) cepat yang diikuti oleh api,
bara atau nyala.
3. KEBAKARAN
• Suatu bencana malapetaka atau musibah yang ditimbulkan oleh api yang tidak diharapkan yang
sukar dikuasai dan merugikan.
4. DAERAH BAHAYA
• Suatu daerah / tempat yang memiliki potensi untuk menjadi sumber api dan penjalaran api.
5. PENCEGAHAN BAHAYA KEBAKARAN
• Upaya yang dilakukan sebelum terjadi kebakaran dengan maksud menekan atau mengurangi
faktor yang dapat meyebabkan timbulnya kebakaran ; digunakannya sarana/alat untuk
melokalisir api dan mencegah rambatan api dengan tujuan untuk mencegah meluasnya
kebakaran.
FIRE THEORY Untuk dapat terjadinya suatu proses pembakaran/api diperlukan 3 komponen dasar yaitu : Bahan yang dapat
terbakar, Oksigen dan Panas. Bilamana ketiga komponen tersebut berada alam suatu konsentrasi yang memenuhi
syarat maka terjadilah reaksi tersebut yang dalam ilmu kebakaran disebut sebagai Api Awal.
Sebagian panas yang dihasilkan oleh api awal tadi akan diserap oleh bahan bakar yang kemudian akan melepaskan
uap/gas yang dapat/mudah terbakar yang kemudian akan bercampur dengan oksigen di udara dan akan terbakar,
demikian seterusnya sehingga terjadi proses pembakaran yang berkesinambungan selama ketiga komponen itu
dalam suatu konsentrasi yang seimbang. Yang biasa disebut sebagai Segitiga Api.
Pada perkembangan ilmu kebakaran selanjutnya ditemukan bahwa materi yang terbakar mengalami Pyrolysis
(peristiwa dikomposisi kimiawi karena pengaruh panas) sehingga materi tersebut menimbulkan uap dan gas yang
akan membentuk suatu campuran mudah menyala (Flammable) dengan udara.
Selanjutnya apabila temperatur mencapai titik nyala campuran tadi, akan timbul lagi proses pembakaran, demikian
seterusnya. Reaksi ini terus berlangsung sehingga semua bahan/benda habis dan panas telah terbuang semua
ataupun oksigen terpakai habis sehingga suhu bakar berkurang dibawah titik nyalanya dan proses pembakaran
berangsur-angsur berhenti.
Jadi disamping adanya komponen-komponen penunjang terjadinya api awal tersebut, guna mempertahankan api
tetap berlangsung ada komponen lain yang berpengaruh, yaitu komponen keempat yang dikenal dengan RANTAI
REAKSI KIMIA (Chemical Chain Reaction).
Dengan adanya komponen keempat maka Segitiga Api berkembang lebih sempurna lagi menjadi Tetrahedron Api
(The Fire Tetrahedron).
16