NUM CorporationEngineering Department
Axium PowerSoftware under OS
Windows 7
NUM INFORMATION
US N° 180 1/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
Windows 7 – Professional and Home Premium – 32 Bit Version
NUMTools Workshop (ver. P) Installation
Windows 7 generally supports 32- and 64-bit architectures (x86 and x64). ForNUMTools version “P” a 32-Bit OS is definitely required, because the Vista32X_Waydrivers will ONLY work with a 32-bit operating system.
The Vista32 X_Way drivers rev. 2.6 are not part of the NUM Tool Workshoppackage. They could be obtained separately either from:
NUM FTP Download Scheneider drivers v2.6or
Schneider Electric - Driver Pack V2.6 The Schneider communication drivers pack V2.6 have to be installed before the NUMTool Workshop is loaded. If the drivers are not loaded prior to attempting to load NUMTool Workshop then the following error is displayed:
Installing Unitelway and XIP Windows VISTA/7 Drivers
1. Run the _installdrivers.html file on the installation CD.This will display the following screen:-
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 2/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 2/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
2. Select required driver to load (under Windows VISTA32) :-
a) UNI-TELWAY – Port Com Setup V2.0 IE10 and/or
b) XIP – X_WAY on TCP/IP Setup V2.0 IE10
Note: Selecting either of the above will load in the Drivers Manager before the driver.
3. On the message “Pending Schneider Driver Manager for Vista32” – ClickInstall
4. Follow the on screen prompts
5. Drivers will install with no Finish notification! – Restart PC
Installing NUM Tool Workshop (Ver. P00)
1. Insert CD into PC – AutoPlay displays the below message.Click on Run setup.exe
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 3/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 3/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
2. “Do you want to allow the following program from an unknownpublisher to make changes to this computer?”
Message posted - click Yes to continue – Install shield runs.
3. NUM Tool welcome screen page: click Next to continue.
4. License Agreement screen page: click Yes to continue.
5. Information screen page:click Next to continue.
6. Choose Destination Location screen page: click Next if Location is OK orbrowse to desired location.
7. Selection of Software installation package screen page: Leave Install NUM
Tool and HMI selected - click Next to continue
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 4/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 4/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
8. Selection of the Human Machine Interface screen page: click Next tocontinue.(PC Panel MMI and PC Standard MMI (Apex screens) can be selected if required)
9. Setup Type screen page: Leave Complete selected then click Next tocontinue.
10. Licence message page: click OK to continue
11. User Licence PLCTool and SETTool page: lease enter User Name /Company Name / User Licence – click Next to continue.
12. Select Program Folder screen page: click Next for default location(Location can be changed if necessary).
13. Select communication and driver installation screen page: Please selectthe desired communication – (Com – serial link is default). Then click Next tocontinue.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 5/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 5/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
14. Select language screen page: select Desired Language – click Next tocontinue.
15. Information of installation screen page: click Next to continue.
16. Setup Status screen page: leave as software is configured.
17. “DllRegisterServer in C:\Program Files\CommonFiles\microsoftshared\DAO\dao350.dll succeeded”.
When message is displayed just click click OK to continue
18. SYSTEM UPGRADEMachine Manager required Borland Database Engine
Would you like to install Borland components?
When message is displayed just click Yes to continue
19. Registry Editor message page: click Yes to continue.
20. Second Registry Editor message page: click OK to continue
21. Install Shield Wizard Complete screen page: click Finish to continue
22. Remove installation CD and reboot PC.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 6/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 6/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
XIP-Driver Setup
Setup the CNC Parameters with PC Standard MMI (Apex).
The XIP driver uses the following NC parameters:P100 – N1 - XIP Xway address = 3F (Hex)P124 – CNC TCP/IP Address = 192.168.0.254P125 – CNC Subnet Mask = 255.255.255.0
P100 N1 corresponds to the Station Address in Step 3 below. Range is 0 to 3F Hex (0to 63 decimal)
Setting of the PC Network Adaptor:IP address = 192.168.0.150Subnet Mask = 255.255.255.0
Remark: The above values for parameters and Network settings are example values only.
1. Power up CNC – Connect PC to CNC TCP/IP adaptor with a Cross (X) network cable.
2. Set-up the Network Adaptor Settings(Control Panel > Network and Internet > Network and Sharing Centre > Change AdaptorSettings)In the below example IP Version 4 is modified.
At this point it is possible to ping the CNC from the PC – i.e. ping 192.168.0.254 andcheck response.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 7/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 7/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
3. Open Communication & Language parameter program
(Start -> All Programs -> NUM Tool Win Vista32 -> Communication -> Communication &Language parameter).
Ensure Station under NUM Tool andNUMpass CNC configuration, if NumPass isloaded, is set to CNC P100 N1 value. 3F(hex) in this example
(CNC Parameter 100 value - Range is 0 to 3FThis equal 0 to 63 decimal)
4. Ensure XIP is selected in Type of Communication box.
5. Enter Station Value in NUM Tool Box and NUMpass CNC configuration Box (ifNumpass is loaded).This value equals CNC parameter P100 – N1 . (Set to 3F Hex in this example)
6. Click Validate - “Communication is now set to XIP01” is displayed in the LOADINGwindow.(on subsequent running of the program the loading window will several references to XIP01)
7. Click Configuration – This will display Schneider Drivers Management Properties :-
Select XIP Driver Tab.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 8/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 8/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
8. Click Configuration (Answer Yes to any questions allowing program to makechanges)
IF no XIP has been previously been set-up on the PC then the following warning will bedisplayed :
Click OK to continue
This will then display New XIP profile creation
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 9/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 9/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
Under TCP/IP – Network Adaptor drop down box select the required Adaptor and click
OK (Note TCP/IP Address of PC as set in Step 2. – in this example 192.168.0.150)
This displays the following:
9. Click Bind (not necessary if already performed above).
Under TCP/IP – Network Adaptor Drop down box select the required Adaptor andclick OK (Note TCP/IP Address of PC as set in Step 2. – in this example 192.168.0.150)
10. Enter New Remote Host data as shown belowE.g. Station = CNC / XWAY address = 0 . 63 / IP Address = 192.168.0.254XWAY address = 0 . 63 - P100 N1 = 3F
Deselect Enable automatic detection.Ensure DNS is not selected
Enter Local host XWAY Address = 0.63Note Local Host and New remote host XWAY addresses must have a differentvalue.
11. Click Add button
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 10/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 10/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
12. Click Save – Message “The new configuration has been saved successfully” – click OK
13. Under XIP menu bar– Select Reset – This Resets the XIP driver.(or Stop then Start)
14. Under Test menu select ICMP Ping > Select Ping
15. Close all windows and reboot PC and CNC – Important to do this.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 11/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 11/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
Testing XIP Communication
1. Open Communication & Language parameter program
2. Select Configuration > Select XWAY Test Tab
3. Under Driver box - Name: – Drop down menu - Select XIP
4. Change Remote address: to 0.63.0
5. Select Connect State in request box becomes Connected – icon is active.(there may be a slight delay)
6. Select Start - The request will flash red / yellow and the number will increment.
Com Port Set-up with Unitelway Driver
1. Run Communication & Language parameter program(Start -> All Programs -> NUM Tool Win Vista32 -> Communication ->Communication & Language parameter).
2. Ensure COM is selected in Type of Communication box.
3. Click Validate (There will be several references to COM in the Loading window)
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 12/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 12/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
4. Click Configuration – This will display Schneider Drivers ManagementProperties :
5. Select UNITELWAY Driver Tab
6. Select Configuration. (Answer Yes to any questions allowing program tomake changes)
COM1 is the default Com port. An additional Com port may be shown ifusing a USB - RS232 device – in this
case ensure Force Virtual Com Port(shown below) is selected.
7. Select Edit – to display Station Parameters - the 3 tabs are displayed :-Set values as below.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 13/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 13/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
The Baud rate can be set from 300 to 115200bps.Ensure Unitelway and NumPLC are selected
8. Click OK to close Station Parameters.
9. Click Apply to Reset Unitelway Driver. Drivers Reset is OK is displayed
10. Click OK to exit Unitelway Configuration11. Click OK to exit Schneider Drivers Management
Testing Unitelway Communication
1. Connect Comms cable from NC to PC. (Port 0 in this case)
2. Configure Comms Port on control – P112 N0 = 00 / N1 = 55 / N2 = 01Port 0 / 115200 baud rate
3. Click Configuration – This will display Schneider Drivers ManagementProperties.
4. Select X_WAY Test tab.
5. Select Connect – State in request box becomes Connected – icon is active.
(there may be a slight delay while the correct baud rate is selected)
6. Select Start - The request will flash red / yellow and the number will increment.
7. Select Stop – Select Disconnect. – State to Disconnected.
8. Select OK to close Drivers Manager.
9. Select Exit to close Communication & Language parameters
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 14/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 14/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
HSL PCI Set-up – Windows 7
The document details HSL PCI setup – Driver installation - with Windows 7 (32 Bit)
The HSL PCI C101 board is manufactured by MOXA and has a Num part number of0202206297.
Download the Drivers from the MOXA website – C101.EXE (self extracting zip File)
1. With PC Power off – cable disconnected – fit the HSL PCI card to the PC.(Use a wrist strap – antistatic).
2. Power-up PC.
3. Select the C101.EXE - Right Click – Select Troubleshoot compatibility.
The C101.exe file is run in compatibility mode to ensure it loads the drivers in thec:\windows\System32 folder.
4. Select Try recommended Settings
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 15/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 15/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
5. Test compatibility settings for the program is displayed – Select Start program button
6. When this message appears: “Do you want to allow the following program from anunknown publisher to make changes to this computer ” - Press YES button.
7. A DOS window appears a question displayed “Continue Extraction?”Press Y followed by enter key.
This extracts the necessary files to the C:\Windows\System32 directory (folder).Dos window closes.
8. The Test compatibility settings for the program screen is displayed – Select Cancel button.
9. Go to Device Manager
10. Right Click PCI serial port(Warning symbol on icon – showing a driver problem)
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 16/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 16/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
11. Select Update driver software.
12. Click Browse my computer for driver software.
13. Browse to C:\Windows\System32 folder - Click Next
Searching message is displayed.
7/17/2019 Us 180 NUMTools P Under Windows7
http://slidepdf.com/reader/full/us-180-numtools-p-under-windows7 17/17
Axium Power
Software under OSWindows 7
NUM INFORMATION
US N° 180 17/17
Date:12/23/10
NUM Corporation Phone: 630-505-7722 603 East Diehl Road, Suite 115 Fax: 630-505-7754Naperville, IL 60563-1477 USA Web: www.num.com
14. Windows Security image – acknowledge:
15. Click Install this driver software anyway.
16. Message “Installing Driver software” is displayed.
17. Message “Windows has successfully updated your driver software”
18. Click close
19. Restart PC