+ All Categories
Transcript

Touch-Screen Patient MonitorDRE Waveline Touch

• 12.1”colorTFTdisplaywithatouch-screeninterface

• Multi-leadECGmonitoring

• Newfor2015!MasimoSET®PulseOximetry

• STsegmentmonitoringand72hourstrenddataanalysis

• NIBPlistandOxyCRGdynamicviewdisplay

• Drugdosecalculations

• Largefontdisplaywith4,6and8waveformsshown

• Built-inbattery(optional)

• Built-inthermalrecorder(optional)

• NetworkablewithaCentralMonitoringSystemviaawirelessorwirednetwork

• Compactdesignconvenientformobilemonitoring

• Multi-lingualsettings

• Standbybutton

• RevisedSpO2pitchtoneisstillaudiblewhenSpO2ratedecreases.

• VolumeandSoundsareadjustableandcanbeturnedoffcompletely

• OptiontoprintNumericalDataOnly

• Colorofthewaveformscanbechanged

• Includesveterinaryaccessoriesforparametersordered

User-friendly touch-screen patient monitorMeasures ECG, SpO2 , NIBP, heart rate, temperature and respiration

Intuitive touch-screen displays large fonts and up to eight crisp waveforms

Also available with Anesthetic Agent Monitoring, Automatic Agent I.D., Dual IBP, and Masimo SET® Pulse Oximetry

Upgrade for O.R. use with

optional Anesthesia

Gas Module

1800 Williamson Ct. • Louisville, Kentucky 40223 USA800-477-2006 • 502-244-4444 • FAX: 502-244-0369 www.dreveterinary.com

Touch-Screen Patient MonitorDRE Waveline Touch

PhysicalDimensions&WeightMain UnitDim. 11”Hx12.6”Wx6.2”DWeight Approx.11lbs(5kg)

ApplicationNeonatal,pediatricandadultpatients

OperationEnvironmentPowerSource ExternalACpower

orinternalbatteryACPower 100-240VAC,50/60Hz,

<150VABattery RechargeableLead-Acid;• Operatingtimeundernormal

conditions 1hour• Operatingtimeafter1stlow

batteryalarm 10min.

TemperatureWorking 5°–40°CStorage -20°–65°C

Relative HumidityWorking 30–75%Storage ≤80%

AltitudeOperatingAltitude Upto5,000metersHyperbaricPressure Upto405.3kPa

PerformanceSpecificationsDisplay 12.1”colorTFT,TouchScreenResolution 800x600pixelsTrace 4,6,8or9waveforms

ECG(I,II,III,aVR,aVL,aVF,V1-V6),PLETH,RESP,IBPx2,ETCO

2Indicator Alarmindicator;

PowerindicatorQRSbeepandalarmsound

TrendTime 72hoursRecorder Built-in,thermalarray,

2channels• RecordWidth 48mm• RecorderPaper 50mm• RecordSpeed 25mm/s,50mm/sOxyCRG CombinesHR,SpO

2,andresp.

trendsintoasinglegraph

ECGInput 5-leadECGcableandstandard

AAMIlineforconnectionLeadChoice I,II,III,aVR,aVF,aVL,VGainChoice x0.125,x0.25,x0.5,x1.0,x2.0Filter• Diagnosticmode 0.05–100Hz• Monitoringmode 0.05–75Hz• Surgicalmode 1–20Hz

PerformanceSpecificationsECG continuedECGWaveforms 7channelsPenetrationVoltage 4000VAC50/60HzSweepSpeed 12.5,25and50mm/sHRDisplayRange 15–300bpmAccuracy ±1%or±1bpm,

whicheverisgreater• S-7SegmentDetection 7channels• MeasurementRange -2.0mv–+2.0mv• ArrhythmiaAnalysis 13typesAlarmLimitRangeSetting• Upperlimit 80–400bpm• Lowerlimit 20–150bpm

RESPMeasureMethod RA-LLimpedanceRange 0–120rpmAccuracy ±3rpmAlarmUpper-lowerLimitSetting:• Upperlimit 6–120rpm,• Lowerlimit 3–120rpmSweepSpeed 12.5and25mm/s

NIBPMeasuringTechnology

AutomaticoscillatingmeasurementCuffInflating <30s(0–300mmHg,

standardadultcuff )MeasuringPeriod AVE<40sMode Manual,Auto,STATMeasuringIntervalinAUTOMode 2min–4hrsPulseRateRange 30–250(bpm)MeasuringRange• Adult/PediatricModeSYS 40–250(mmHg)DIA 15–200(mmHg)• NeonatalModeSYS 40–135(mmHg)DIA 15–100(mmHg)Resolution 1mmHgAccuracy:Pressure• MaximumMeanerror ±5mmHg• Max.Standarddeviation 8mmHgOverpressureProtection• AdultMode 280(mmHg)• NeonatalMode 150(mmHg)AlarmLimitSetting• SYS 50–240mmHg• DIA 15–180mmHg

TEMPRange 0–50˚C

(32–122˚F)Accuracy WithoutsensorDisplayResolution 0.1°CAlarmUpper-lowerLimitSetting:• Upperlimit 0-50°C• Lowerlimit 0-50°CChannel 2channels,provideT1,T2,ΔT

PerformanceSpecificationsSPO2ASpO

2 Anti-motionSpO

2SpO

2%Range 0–100%

SpO2Accuracy

• ±2%70–100%,non-motion• ±3%70–100%,motionPulseRateRange 30–250bpmPulseRateAccuracy• ±2bpm(non-motion)• ±3bpm(motion)AlarmUpper-lowerLimitSetting:• Upperlimit 70–100%• Lowerlimit 70–100%SpO

2Probe

• RedLightLEDWavelength 660nm±5nm• InfraredLightLEDWavelength

905nm±10nm

IBP (Option)MeasurementRange -50–300mmHgChannel 2channelsPressureTransducer Sensitivity,5μV/V/mmHgImpedanceRange 300–3000ΩTransducerSites ART,PA,CVP,RAP,LAP,ICPResolution 1mmHgAccuracy ±1mmHgor±2%,

whicheverisgreaterAlarmrange -50–300mmHg

EtCO2 (Option)ModeofSampling SidestreamPrincipleofOperation

Non-dispersiveinfrared(NDIR)singlebeamoptics,dualwavelength,nomovingparts

CO2MeasurementRange

0to150mmHg(0to19.7%,0to20kPa)CO

2CalculationMethod BTPS

(BodyTemperaturePressureSaturated)CO

2Resolution 0.1mmHg(0–69mmHg);0.25mmHg(70–150mmHg)

CO2Accuracy 0–40mmHg±2mmHg;

41–70mmHg±5%ofreading;71–100mmHg±8%ofreading;

101–150mmHg±10%ofreading;Above80breathperminute

±12%ofreadingSamplingRate 100ml/minRespirationRate 2–150bpmRespirationRateAccuracy ±1breathResponseTime <3seconds

(includestransporttimeandrisetime)InspiredCO

2MeasurementRange

3–50mmHg

Also available: AnesthesiaGasandAutomaticAgentI.D.Consultyoursalesrepresentativeforspecifications.

Specifications subject to change without notice.

Technical Specifications

1800 Williamson Ct. • Louisville, Kentucky 40223 USA800-477-2006 • 502-244-4444 • FAX: 502-244-0369 www.dreveterinary.com


Top Related