DESCRIPTION The Aquamonix MP47 and MP65 Multiparameter Sensors provide a complete self contained measurement and data logging system for a wide range of environmental water monitoring applications. The sensors provide the ability to measure single or multiple water quality parameters (up to 4 parameters on the MP47 and 6 parameters on the MP65) within the single sensor providing users the choice to select the parameters which best suits their application.
Users have a choice of the following parameters:
• Pressure
• pH
• Oxygen Reduction Potential
• Electrical Conductivity
• Temperature
• Turbidity
• Optical Dissolved Oxygen
The sensor includes an internal data logger to provide long term data collection at remote sites. The sensor can be fitted with an external cable, or with an on-board battery pack for true stand alone operation. Serial output (RS232 or RS485) in Modbus or optional SDI12 allow connection to an external data logger or process
controller as well as options for remote telemetry connection.
A durable corrosion resistant body, rugged construction utilising double “O-Ring” ensures suitability for harsh environments. The sensor comes fitted with a fully moulded polyurethane cable as standard. Other cable options are available.
The parameters selected are available in various ranges. The pressure sensors can be supplied as either a gauge (vented) or absolute (non vented) sensor. Gauge sensors utilise the closed vent system (CVS) to provide barometric pressure venting with minimal maintenance. The MP65-3000 is ideal for use in hydrographic and environmental water monitoring applications, including tidal and estuary monitoring. The MP47-3000 sensor uses a slimline housing suitable for groundwater monitoring. Both units are easy to configure and operate using the supplied SensorMate software.
FEATURES • Low power usage enables long term
remote operation
• Internal data logger for collection of data during critical events
• Telemetry options via mobile phone, radio and satellite
• SDI12 cable adaptor unit for connection into data logger or controller.
• Modbus RTU or ASCII
• RS232 or RS485/422
BENEFITS • Can be installed in active waters
(acidic or salty conditions)
• Reliable and robust sensor ensures minimal servicing visits
• Suitable for marine applications and waterways with high sediment loads
• Easy to configure logger – quick retrieval of data using SensorMate software
• Graphical and tabular display – export to spreadsheet format.
• Stand alone operation with on board Battery Pack
• Various cable options for telemetry and integration applications
APPLICATIONS • Monitoring of streams and rivers,
lakes and urban waterways
• Groundwater and Surface water hydrographic data collection
• Water supply storages, Runoff Studies, Flood Warning
• Tidal, estuary and oceanographic monitoring.
MP47 (UP TO 4 PARAMETERS) MP65 (UP TO 6 PARAMETERS)MULTI PARAMETER WATER QUALITY SENSORS
DIMENSIONS MP47
MP47
80.0300.0
27.0
55.0
584.0
122.0
47.0
93.0
AQUAMONIX
PARAMETER DETAILThe Pressure sensor utilises a robust ceramic capacitance transducer for long term reliable pressure/depth sensing and a highly accurate thermistor for temperature measurement. Multi-point linearity and temperature calibration over the full operating ranges of Pressure and Temperature ensures stable, repeatable and accurate readings in the field.
PRES
SURE
Measurement technique ½″ Ceramic Capacitance Sensor
Standard pressure ranges available Gauge 2.5, 5, 10, 20, 40, 75, 100 m Absolute 20, 40, 75, 100 m
Max over range 4 times Full Scale range.
Other ranges available Yes – Calibration charge may apply – refer sales office
Overall accuracy (combined linearity, hysteresis
and repeatability)
+/– 0.1% Full Scale range
Long term stability 0.2% full scale per annum
Resolution Depth – 0.001 m, Temp – 0.05°C
The pH sensor utilises a robust gel filled pH electrode together with the optical isolation and advanced signal conditioning to ensure long term accurate data.
PH
Measurement technique Gel-filled glass electrode with internal Ag/AgCl reference; Field replaceable electrode
Sensor range 0–14 pH
Resolution 0.001 pH
Accuracy +/– 0.2 pH
The ORP (Oxygen Reduction Potential) sensor is similarly packaged and utilises a platinum electrode. Both sensors feature a field replaceable electrode to further improve long term performance and reduce maintenance costs.
ORP
Measurement technique Platinum electrode with internal Ag/AgCl reference; Field replaceable electrode
Sensor range –1000 mV – +1000 mV
Resolution 1 mV
Accuracy +/–2% full scale
Electrical Conductivity sensors utilise a reliable and robust toroidal sensor for conductivity measurement and thermistor for temperature measurement. Multi-point linearity and temperature calibration over the full operating range ensures stable, repeatable and accurate readings in the field. (Note: pH cannot be used in combination with EC sensor in the MP47)
EC
Measurement technique Toroidal Conductivity
Standard EC ranges available 0–1000 µS/cm, 0–2000 µS/cm, 0–5000 µS/cm, 0–10000 µS/cm, 0–20000 µS/cm, 0–60000 µS/cm, 0–70000 µS/cm
Other ranges are available Yes – calibration charge may apply – refer sales office
Overall accuracy (combined linearity, hysteresis
and repeatability)
+/–1% full scale range
Resolution EC – 1 µS
Turbidity sensors feature an integral wiper and digital filtering technology to provide long term reliable operation at remote sites where bio-fouling or sedimentation can occur.
TURB
IDIT
Y
Measurement technique 90° Infra-red (ISO7027)
Standard ranges available (factory set) 100 NTU
Resolution +/–1%
Linearity –1 % full scale range
Temperature coefficient +/–0.2%/°C
Calibration standard APS AEPA polymer solutions 0, 100 NTU, 400 NTU, 1000 NTU
The Optical Dissolved Oxygen sensors utilise fluorescence DO sensor technology. The sensor’s fast response allows users to capture rapid changes in DO.
OPT
ICAL
DO
Measurement technique Oxygen fluorescence detection method
Sensor range 0–200% saturation (0–20 ppm)
Resolution 0.1%
Accuracy Oxygen 1% of reading or 0.02 ppm whichever is greater
Response time 90% of DO change within 60 seconds
MULTI PARAMETER WATER QUALITY SENSORS
AQUAMONIX
MULTI PARAMETER WATER QUALITY SENSORS
OPTIONAL EXTRAS AND ACCESSORIES• On Board Battery Pack (includes
Housing and Battery Pack)
• SDI12 Adapter (connects to end of sensor cable for serial output to logger)
• Closed Vent System – if gauge pressure sensor selected
• Communications Cables (serial to USB connector on laptop)
CUSTOMER SUPPORTAquamonix also offer a range of customer support functions:
• Field installation
• Data management
• Project integration
• Technical and sales support
• Factory calibration and re-certification
• Product servicing and repair
SDI-12 Adaptor (7SDI-1000)
Closed Vent System (7CVS-001)
SENSOR SPECIFICATIONSTemperature measurement technique Integrated precision thermistor
Operating ranges 0–50°C
Overall temperature accuracy (combined linearity,
hysteresis and repeatability)
0.2°C
Sensor Outputs Internal Data Logger – serial data via SensorMate software Optional adaptor provides SDI12 serial output (3 wire)
Storage temperature –5°C – +60°C
Cable type Polyurethane sheathed cable, OD 8 mm, with 3 mm vent tube, moulded entry, HS7 connector for serial connection.
Standard cable lengths 10, 20, 30, 50, 100, 150 m (32, 65, 100, 165, 325, 490 ft)
Non-standard cable lengths Yes (Extra cable moulding time may be required)
Power supply 8 to 30 V DC (at sensor), or on-board battery pack (option)
Power ESD protection 2000 volts
Current consumption Sleep <0.2 mA, logging 20 mA, communicating 30 mA (consumption rates vary depending on parameters selected)
Sensor warm-up time Up to 5 seconds
On-board battery pack (option) Housing screws to sensor size (OD × L) 47 mm × 250 mm
Battery capacity 9 × Lithium AA (3.6Volt) – Total capacity 5.2 Ah @ 10.8 V
Typical field life (battery pack) Over 12 months’ remote operation @ 15-minute data logging.
Internal data logger Non-volatile, battery backed RAM with real time clock
Memory size 4 Mb capacity, with user-selectable wrap function
Measuring units User definable (Metric and Imperial US units)
Data storage 250,000 readings. (Typically 5-minute data for >12 months)
Logging frequency User selectable from 1 second up to once per day
Dimensions (L × OD) *MP47 – 355 mm × 47 mm (14″ × 1.78″), MP65 – 355 mm × 65 mm (14″ × 2.5″) – Optional End Mount Batt Pack – 300 mm × 47 mm
Weight MP47 – 550 g plus cable weight (665 g per 10 m length) MP65 – 650 g (plus cable weight (665 g per 10 m length)
Wetted materials Acetal, ceramic, 316 passivated stainless steel, polyurethane, viton
* Variable depending on parameters chosen. Drawings show example dimensions.
03AQUAMONIX
MP47/MP65MULTI PARAMETER WATER QUALITY SENSORS
DIMENSIONS MP65
715.0
55.0
27.0
83.5120.0129.5300.0
MP65
64.5
63.5
115.0
HOW TO ORDER
OR
MP47
Depth
pH
ORP
EC
Inline Option1
Choose 1 parameter
?
Inline Option2
Choose 1 parameter
Inline Option3
Choose 1 parameter
N/A
Depth
pH
ORP
EC
?
N/A
Depth
pH
ORP
EC
?
N/A
Depth
pH
ORP
EC
?
Ext Temp
Turbidity
OpticalDO
End SensorChoose
1 parameter
MP65
Depth
pHORP
MPMount
N/A
MP Mount(on MP65 only)Must choosepH or ORP withoption of adepth sensor
Model MP47-3000 or MP65-3000 (dependent on the parameters chosen)
Pressure Transducer Selection – Pressure sensor type – Gauge or Absolute or N/A, Sensor depth full scale range (m)
Electrical Conductivity selection – Slimline or Standard Head, Full-scale EC range (µS/cm) Normalised, or Non-normalised, EC shroud required, Fast Response Temp Button option.
pH – (cannot be used in combination with EC in the MP47)
Turbidity Selection – select range (100, 400 or 1000NTU)
Body material – Acetal or stainless steel
Cable length (m)
Specify battery pack or any other options.
PENTAIR ENVIRONMENTAL SYSTEMS
PS1000PRESSURE SENSOR
CLOUDBASED DATA
IRRIGATIONAUTOMATION
REMOTEMONITORING
WATERMEASUREMENT
02 AQUAMONIX
DESCRIPTIONThe enhanced features and performance of the proven PS1000 pressure sensor provides users with an affordable solution to a wide range of water level and pressure monitoring applications. The PS1000 has a standard, 2 wire, loop powered 4–20 mA output with an option for 0–2.5 V DC. Key features include the ability to re-range the sensor, as well as adjust the fluid density and gravity to suit specific applications.
The sensor is ideal for use in groundwater, surface water and a wide range of monitoring and environmental projects. A durable corrosion resistant body, rugged ceramic capacitance transducer and double O ring sealing ensures suitability for harsh environment applications. The sensor comes fitted with a moulded polyurethane cable. An optional SDI-12 adapter can provide a level and temperature output for external controllers or data loggers.
The sensor can be supplied in various gauge (vented) or absolute (non vented) pressure ranges. Gauge sensors utilise a closed vent system (CVS). This provides barometric pressure venting of the sensor, without the need to continually replace desiccant.
The PS1000 sensor is easy to install and provides users with a rugged and reliable solution to long term monitoring. For more information please contact your nearest sales office.
FEATURES• Loop powered – battery or solar
• 4–20 mA or 0–2.5 V DC outputs
• 0.1% FS accuracy
• Field re-ranging and calibration
• User inputs for fluid density and local gravity
• Double O-ring design and moulded cable gland
• Acetal construction
• ½˝ diameter ceramic capacitance transducer
• Long term stability better than 0.2% per annum
• Optional SDI-12 adaptor for serial output
• Optional threaded fitting for Process connection
BENEFITS• Can be installed in active waters
(acidic or salty) that would damage a stainless steel sensor.
• No need for regular desiccant replacement resulting in fewer field visits
• Low cost of ownership and minimal maintenance
• Ease of use and long term reliability
APPLICATIONS• Sewer wet wells
• Bore hole monitoring
• River and dam level monitoring
• Flood warning systems
• Tank level monitoring
• Process level and pressure monitoring
CUSTOMER SUPPORTAquamonix also offer a range of customer support functions:
• Field installation
• Data management
• Project integration
• Technical and sales support
• Factory calibration and re-certification
• Product servicing and repair
PS1000PRESSURE SENSOR
DIMENSIONS
11.0 27.0 55.0235.0
328.0
PS1000
47.0
03AQUAMONIX
PS1000 SPECIFICATION
Measurement technique ½” ceramic capacitance transducer
Std ranges available Gauge Absolute
2.5, 5, 10, 20, 40, 75, 100 m 20, 40, 75, 100 m
Other ranges available Yes (consult sales office)
Sensor output 4–20 mA, or optional 0–2.5 V DC (SDI12 via adaptor)
Overall accuracy (combined linearity, hysteresis and repeatability)
+/–0.1% full scale
Long term stability 0.2% full scale per annum
Zero offset and full scale maximum variation +/–0.02 mA
Cable type Polyurethane sheathed cable, OD 8 mm, with 3 mm vent tube, Aramid reinforced, moulded entry, bare wire connection
Standard cable lengths 10,20,30,50,100,150 m (32,65,100,165,325,490 ft)
Non-standard cable lengths Yes (Extra cable moulding time may be required)
Closed Vent System (CVS) Gauge sensors must be fitted with a CVS
Power supply 8 to 30 V DC (at sensor) loop powered
Reverse polarity protection Yes
Surge current protected To 2 kV
Warm-up time to stable reading <150 ms
Current consumption Up to 20 mA while turned on, 0 mA when off
Operating temperature 0–50°C
Storage temperature –5°C – +60°C
Max over pressure At least twice the full scale range
Dimensions (L × OD) 328 mm × 47 mm (12.91” × 1.85”)
Weight 550 g plus cable weight (665 g per 10 m length)
Wetted materials Acetal, ceramic, 316 passivated stainless steel, polyurethane, viton
OPTIONAL EXTRAS AND ACCESSORIES• For all Gauge (vented) Sensors,
a Closed Vent System must also be fitted. (each CVS unit can handle up to 70 m of vented cable)
• Sensors are normally supplied with a moulded cable pre cut to required length.*
• BSP Pressure Adaptor (Part No. 492-0238) for process connection for pressure monitoring. (Gas Bubbler, Pipelines, Tanks)*
• Protective Copper Nose Cone (Part No. 492-0241) – prevents marine and biological growth on sensor face*
• Serial Breakout adapter (Part No. 085-0080) – provides easy wiring connection for field adjustments and calibration*
• SDI12 Adaptor Unit – (Part No. 7SDI-1000) provides 3 wire SDI12 serial output for Data Logger*
HOW TO ORDERThe following information will be required:
• Sensor full scale range (specify range in m)
• Sensor type (Gauge or Absolute)
• Output required (4–20 mA or 0–2.5 V)
• Moulded cable length (specify length in m)
• Closed Vent System (for Gauge sensors)
• Accessories (Nose cone, Breakout adapter, SDI12 adapter)*
* Consult your Aquamonix sales representative for further details.
Serial Breakout Adaptor (085-0080)
Closed Vent System (7CVS-001)
SDI-12 Adaptor (7SDI-1000)
PENTAIR ENVIRONMENTAL SYSTEMS
PS7000PRESSURE SENSOR
CLOUDBASED DATA
IRRIGATIONAUTOMATION
REMOTEMONITORING
WATERMEASUREMENT
02 AQUAMONIX
DESCRIPTIONThe enhanced features and performance of the proven PS7000 pressure sensor provides users with an affordable solution to a wide range of water level and pressure monitoring applications. The PS7000 has a standard, 2 wire, loop powered 4–20 mA output with an option for 0–2.5 V DC. Key features include the ability to re‑range the sensor, as well as adjust the fluid density and gravity to suit specific applications.
The sensor is ideal for use in groundwater, surface water and a wide range of monitoring and environmental projects. A durable corrosion resistant body, rugged ceramic capacitance transducer and double O‑ring sealing ensures suitability for harsh environment applications. The sensor comes fitted with a moulded polyurethane cable. An optional SDI‑12 adapter can provide level and temperature outputs for external controllers or data loggers.
The sensor can be supplied in various gauge (vented) or absolute (non vented) pressure ranges. Gauge sensors
utilise a closed vent system (CVS). This provides barometric pressure venting of the sensor, without the need to continually replace desiccant.
The PS7000 sensor is easy to install and provides users with a rugged and reliable solution to long term monitoring. For more information please contact your nearest sales office.
FEATURES• Loop powered – battery or solar
• 4–20 mA or 0–2.5 V DC outputs
• 0.1% FS accuracy
• Field re‑ranging and calibration
• User inputs for fluid density and gravity
• Double O‑ring design and moulded cable gland
• ½″ diameter ceramic capacitance transducer
• Long term stability better than 0.2% per annum
• Optional SDI‑12 adaptor for serial output
• Optional threaded fitting for process connection
BENEFITS• Robust 316 stainless steel body
material for harsh environments
• No need for regular desiccant replacement resulting in fewer field visits
• Low cost of ownership and minimal maintenance
• Ease of use and long term reliability
APPLICATIONS• Sewer wet wells
• Bore hole monitoring
• River and dam level monitoring
• Flood warning systems
• Tank level monitoring
• Process level and pressure monitoring
CUSTOMER SUPPORTAquamonix also offer a range of customer support functions:
• Field installation
• Data management
• Project integration
• Technical and sales support
• Factory calibration and re‑certification
• Product servicing and repair
PS7000 PRESSURE SENSORWATER LEVEL & TEMPERATURE
DIMENSIONS
180.0 55.0
PS7000
22.0
278.0
43.0
03AQUAMONIX
PS7000 SPECIFICATION
Measurement technique ½″ ceramic capacitance transducer
Standard ranges available Gauge Absolute
2.5, 5, 10, 20, 40, 75, 100 m 20, 40, 75, 100 m
Other Ranges available Yes (consult sales office)
Sensor output 4–20 mA, or optional 0–2.5 V DC (SDI12 via adaptor)
Overall accuracy (combined linearity, hysteresis and repeatability)
+/–0.1% full scale
Long term stability 0.2% full scale per annum
Zero Offset and full scale maximum variation +/–0.02 mA
Cable type Polyurethane sheathed cable, OD 8 mm, with 3 mm vent tube, Aramid reinforced, moulded entry, bare wire connection
Standard cable lengths 10, 20, 30, 50, 100, 150 m (32, 65, 100, 165, 325, 490 ft)
Non-standard cable lengths Yes (Extra cable moulding time may be required)
Closed Vent System (CVS) Gauge sensors must be fitted with a CVS
Power supply 8 to 30 V DC (at sensor) loop powered
Reverse polarity protection Yes
Surge current protected To 2 kV
Warm-up time to stable reading <150 ms
Current consumption Up to 20 mA while turned on, 0 mA when off
Operating temperature 0–50°C
Storage temperature –5°C – +60°C
Max over pressure At least twice the full scale range
Dimensions (L × OD) 278 mm × 22 mm (11″ × 0.86″)
Weight 300 g plus cable weight (665 g per 10 m length)
Wetted materials Ceramic, 316 passivated stainless steel, polyurethane, viton
Process connection ¼″ BSP female (remove nose cover)
OPTIONAL EXTRAS AND ACCESSORIES• For all gauge (vented) sensors,
a Closed Vent System must also be fitted. (each CVS unit can handle up to 70 m of vented cable)
• Sensors are normally supplied with a moulded cable pre cut to required length. Protective Copper Nose Cone (Part No. 092‑1037) – prevents marine and biological growth on sensor face and some galvanic corrosion protection *
• Serial Breakout Adaptor (Part No. 085‑0080) – provides easy wiring connection for field adjustments and calibration*
• SDI12 Adaptor Unit (Part No. 7SDI‑1000) provides 3 wire SDI12 serial output for Data Logger*
• ¼″ G process adapter (Part No. 092‑1038) – Allows connection to standard threaded fittings *
HOW TO ORDERThe following information will be required:
• Sensor Full Scale Range (specify range in m)
• Sensor Type (Gauge or Absolute)
• Output Required (4–20 mA or 0–2.5 V)
• Moulded Cable length (specify length in m)
• Closed Vent System (for Gauge Sensors)
• Accessories * Consult your Greenspan sales representative for further details.
Serial Breakout Adaptor (085-0080)
Closed Vent System (7CVS-001)
SDI-12 Adaptor (7SDI-1000)
PENTAIR ENVIRONMENTAL SYSTEMS
PH1000 SENSOR
CLOUDBASED DATA
IRRIGATIONAUTOMATION
REMOTEMONITORING
WATERMEASUREMENT
02 AQUAMONIX
DESCRIPTIONThe PH1000 is a fully submersible sensor, well proven to withstand harsh field conditions. Applications include the salty or acidic water conditions found in sewer, surface and groundwater. The sensor requires low voltage power supply and provides a calibrated 4–20 mA output.
Designed with input and support from real users, the PH1000 is a rugged sensor that is also easy to service and clean in the field. The smooth lines of the durable Acetal body with double O-ring design minimise ragging in sewer applications. The shrouds that protect the electrode from impact are easily removed for cleaning. The sensor is fitted with a moulded cable with a tough, polyurethane outer sheath that is reinforced with strong Aramid fibres that can support many times the sensor weight.
A special feature of the combination pH electrode is a reference protection ring. Made from porous PTFE which is impregnated with a special conductive gel, this ring prevents chemical or biological fouling from reaching the
reference. The low cost protection ring can be simply replaced if it is contaminated or fouled, extending the life of the combination electrode. At the end of its life, the electrode can be replaced by the user in the field without the need to return the sensor to the factory.
The pH1000 sensor is easy to install and provides a reliable solution to long term monitoring. For more information please contact your nearest sales office.
FEATURES• Field replaceable, gel-filled pH
electrode
• Innovative replaceable reference protection ring
• Robust, easy clean design
• Optically isolated signal conditioning electronics
• Low power energy saving enables long-term remote operation
BENEFITS• Rugged electrode design provides
unparalleled remote operations
• Operation on remote power source for long periods
• High reliability means critical measurements are not lost through sensor down time
• Minimal field servicing and reduced field visits
• Electrode field replacement to maintain continuous accurate readings
APPLICATIONS• Sewer monitoring
• Monitoring of streams and rivers, lakes and urban waterways
• Catchment studies and forestry management
• Water supply storages including stratification studies
• Water and wastewater treatment monitoring
• Groundwater analysis and monitoring
• Industrial process, Acid Sulphate studies
• Tidal, estuary and oceanographic monitoring
PH1000SENSOR
DIMENSIONS
PH1000
364.5
55.027.0237.045.5
47.0
03AQUAMONIX
PH1000 SPECIFICATION
Measurement technique Gel-filled glass electrode with internal Ag/AgCl reference Field Replaceable electrode
Sensor range (factory calibrated) 0–14 pH (4 mA = 0 pH, 20 mA = 14 pH)
Sensor output Analogue 4-20 mA
Accuracy +/–0.2 pH (+/–0.2 mA)
Cable type Polyurethane sheathed cable, OD 8 mm, Aramid reinforced, moulded entry, bare wire connection
Standard cable lengths 10, 20, 30, 50, 100, 150 m (32, 65, 100, 165, 325, 490 ft)
Non-standard cable lengths Yes (Extra cable moulding time may be required)
Power supply 10–14 V DC (at sensor)
Reverse polarity protection Yes
Surge current protected To 2 kV
Warm-up time to stable reading 2 sec
Current consumption 10 mA to 30 mA while turned on
Operating temperature 0–50°C
Storage temperature –5°C – +60°C
Depth rating (water column) 100 m
Weight 500 g plus cable weight (665 g per 10 m length)
Dimensions (L × OD) 364.5 mm × 47 mm (14.35″ × 1.85″)
Wetted materials Acetal, 316 passivated stainless steel, polyurethane, viton
PH1000SENSOR
OPTIONAL EXTRAS AND ACCESSORIES• Field replaceable electrode kit
(Part No. 570-0230)
• Reference protection ring (Part No. 671-9123)
• Copper electrode shroud (Part No. 092-1034)
HOW TO ORDERThe following information will be required:
• Cable length (m)
• Any other accessories
CUSTOMER SUPPORTAquamonix also offer a range of customer support functions:
• Field installation
• Data management
• Project integration
• Technical and sales support
• Factory calibration and re-certification
• Product servicing and repair
PENTAIR ENVIRONMENTAL SYSTEMS
TS1000 TURBIDITY SENSOR
CLOUDBASED DATA
IRRIGATIONAUTOMATION
REMOTEMONITORING
WATERMEASUREMENT
02 AQUAMONIX
DESCRIPTIONThe AquamonixTS1000 Turbidity Sensor provides a reliable and cost effective solution for monitoring turbidity in a wide range of environmental applications. The integral wiper assembly provides long term reliable operation at remote sites where bio-fouling or sedimentation is likely.
The TS1000 is a low power unit and provides both 4–20 mA and 0–2.5 V outputs. The wiper is triggered by a separate control wire.
The sensor is ideal for use in all water monitoring applications, including tidal and estuary monitoring.
A durable acetal body, double O-ring design ensures suitability for harsh environment applications. It can be supplied in various ranges, and comes fitted with a moulded polyurethane cable.
The TS1000 sensor is easy to install and provides users with a rugged and reliable solution to long term monitoring. For more information please contact your nearest sales office.
FEATURES• Turbidity measurement conforms to
ISO7027
• Integral self cleaning wiper
• Rugged acetal body
• Field replaceable wiper pad
BENEFITS• Can be installed in active waters
(acidic or salty) where stainless steel is not suitable
• Reliable and robust sensor ensures minimal field visits for maintenance
• Suitable for marine applications and waterways with high sediment loads
APPLICATIONS• Monitoring of streams and rivers,
lakes and urban waterways
• Catchment studies and forestry management
• Water supply storages including stratification studies
• Intermediate and final effluent treatment monitoring
• Drinking water filtration efficiency
• Tidal, estuary and oceanographic monitoring
CUSTOMER SUPPORTAquamonix also offer a range of customer support functions:
• Field installation
• Data management
• Project integration
• Technical and sales support
• Factory calibration and re-certification
• Product servicing and repair
TS1000TURBIDITY SENSOR
DIMENSIONS
TS1000
235.0 27.0 55.0
400.5
47.0
83.5
03AQUAMONIX
TS1000 SPECIFICATION
Measurement technique 90° Infra-red (ISO7027)
Std ranges available (factory set) 100 NTU 400 NTU 1,000 NTU
Resolution 0.1 NTU 0.2 NTU 0.3 NTU
Linearity @ 25°C +/–1% +/–1% +/–3%
Temperaturecoefficient +/–0.2%/°C +/–0.1%/°C +/–0.1%/°C
Sensoroutputs 4–20 mAand0–2.5 VDC
Calibration standard APSAEPApolymersolutions0,100 NTU,400 NTU,1000 NTU
Cabletype Polyurethanesheathedcable,OD8 mm,aramidreinforced,mouldedentry,barewireconnection
Standard cable lengths 10,20,30,50,100,150 m(32,65,100,165,325,490 ft)
Non-standardcablelengths Yes(Extracablemouldingtimemayberequired)
Powersupply 8to30 VDC(atsensor)
PowerESDprotection 2000 volts
Currentconsumption Sensor15–40 mAwhileoperating Plusextra30–35 mA–whilewiping
Sensorwarm-uptime 10 seconds
Wiperarrangement SiliconwiperbladeonPVCarm.Fieldreplaceable
Wipercontrol PullcontrolwiretoGNDmomentarily Pulsetimerequired>50 ms
Wipertime <8seconds(1revolution)
Operatingtemperature 0–50°C
Depthrating(watercolumn) 100 m
Storagetemperature –5°C – +60°C
Weight 500 gpluscableweight(665 gper10 mlength)
Dimensions(L×OD) 400.5 mm×47 mm(15.77″ ×1.85″)
Wetted materials UPVC,Acetal,316passivatedstainlesssteel,polyurethane,viton
Integral wiper silicone wiper blade provides self-cleaning of sensor lens for long-term unattended operation.
TS1000TURBIDITY SENSOR
OPTIONAL EXTRAS AND ACCESSORIES• Spare wiper kit (Part No. 5TW-001)
HOW TO ORDERThe following information will be required:
• Sensor full scale range (NTU)
• Moulded cable length (m)
PENTAIR ENVIRONMENTAL SYSTEMS
EC250 ELECTRICAL CONDUCTIVITY SENSOR
CLOUDBASED DATA
IRRIGATIONAUTOMATION
REMOTEMONITORING
WATERMEASUREMENT
02 AQUAMONIX
DESCRIPTIONThe EC250 Electrical Conductivity Sensor provides highly accurate conductivity measurements in a wide range of hydrological applications.
Exceptional reliability and chemical resistance are guaranteed by the state of the art toroidal measuring system. Advanced microprocessor technology provides highly accurate temperature compensated measurements.
Field conductivity measurements in ionised solutions have traditionally been fraught with inaccuracy due to temperature and electrode effects. The EC250 Sensor substantially eliminates these conventional sources of error. A larger sized toroidal sensor element uses the free ions in solution as a conductive path between two shielded ferrite transformer cores. This system eliminates errors caused by electrode degradation. An advanced compensation algorithm in the on-board microprocessor substantially reduces system non-linearity and temperature drift errors.
The sensor is ideal for use in a
wide range of monitoring and environmental projects. A durable corrosion resistant body and double O ring sealing ensures suitability for harsh environment applications. The sensor comes fitted with a moulded polyurethane cable.
The EC250 is easy to install and provides users with a rugged and reliable solution to long term monitoring. For more information please contact your nearest sales office.
FEATURES• Toroidal sensing technology
eliminates electrode corrosion effects guaranteeing long life and reduced field service.
• On-board temperature measurement and microprocessor controlled temperature compensation and linearisation ensure highly accurate readings in demanding conditions.
• Sensor can be field calibrated with Aquamonix calibration software.
• Separate conductivity and temperature outputs
• Raw conductivity or on-board normalisation of conductivity to 25°C
BENEFITS• Low cost of ownership and minimal
maintenance
• Ease of use and long term reliability
APPLICATIONS• STP aeration tanks
• Borehole observations
• Tidal and estuarine studies
• Effluent monitoring
• River and stream measurement
CUSTOMER SUPPORTAquamonix also offer a range of customer support functions:
• Field installation
• Data management
• Project integration
• Technical and sales support
• Factory calibration and re-certification
• Product servicing and repair
EC250ELECTRICAL CONDUCTIVITY SENSOR
DIMENSIONS
EC250
115.0
27.0
330.0 55.0
561.5
63.5
149.5
47.0
03AQUAMONIX
EC250 SPECIFICATIONS
Measurement technique Toroidal measuring system
Standard EC ranges available 0–1000 µS/cm, 0–2000 µS/cm, 0–5000 µS/cm, 0–10000 µS/cm, 0–20000 µS/cm, 0–60000 µS/cm & 0–70000 µS/cm Other ranges are available to order. A calibration charge applies to non-standard ranges.
Outputs EC: 4–20 mA, 0–2.5 V, or 0–1 V Temperature: 4–20 mA, 0–2.5 V, or 0–1 V
Linearity Temperature 0.2%, EC 0.2%
Temperature accuracy 0.2ºC
EC accuracy, normalised to 25ºC 1% FS @ 25ºC
EC accuracy, non-normalised 0.7% FS @ 25ºC
Cable type Polyurethane sheathed cable, OD 8 mm, Aramid reinforced, moulded entry, bare wire connection
Standard cable lengths 10, 20, 30, 50, 100, 150 m (32, 65, 100, 165, 325, 490 ft)
Non-standard cable lengths Yes (Extra cable moulding time may be required)
Power supply 8–27 V
Reverse polarity protected Yes
Surge protected to 2 kV
Warm-up/reading time 1 sec
Current consumption 40–90 mA (dependent on output)
Operating temperature 0–50°C
Storage temperature –5°C–60°C
Depth rating 100 m
Weight 1.76 kg (Stainless Steel) 950 g (Acetal)
Dimensions Length 561.5 mm (22.11″ × 2.57″) OD 63.5 mm (Stainless Steel or Acetal)
Wetted materials 316 Stainless Steel, Acetal, Acrylic
Software supplied ECFA
EC250ELECTRICAL CONDUCTIVITY SENSOR
OPTIONAL EXTRAS AND ACCESSORIES• Communications cable for use with
ECFA software (Part No. 5CC-200)
HOW TO ORDERThe following information will be required:
• Model EC250
• EC Range
• Normalised or non-normalised
• EC shroud fitted (Y/N)
• Body type
• Cable length (m)
• Output (current/voltage)
• Any other accessories.
www.aquamonix.com.au Ph: 1300 797 246
New South Wales: Ph: (02) 8710 4040268 Milperra Rd, Milperra, NSW 2214
Victoria: Ph: (03) 5821 404419a New Dookie Rd, Shepparton, VIC 3630