Page 1: ZKK& dKW >Ky ^W /&/ d/KE^ZKK& dKW >Ky ^W /&/ d/KE^ Z Ç o W } o Ç } Ç o v } } o Ç u } Ç D ] o o l hs ] o ] Ì W } o Ç } Ç o v } } o Ç u X í ì ì } X í ï ñ Á o o Z ] l

ZKK&dKW>Ky^W/&/d/KE^ ZĞĐLJĐůĞĚ WŽůLJƉƌŽƉLJůĞŶĞ ŽƉŽůLJŵĞƌ

Body Material Black UV stabi l i zed Polypropylene Copolymer .100" to .135" wal l thickness

Base Material 1" thick by 25ps i , type 4 closed cel l s tructura l foamDimensionsWeight

8-7/8" square by 4-1/2" high, top accessory adds 1-1/2" to height for 6" height require-ments , Blox interlock end to end for wide multi -piping platforms. Weight: 1lb per Blox

Load Bearing Max load per Blox—Single Point Load: 250lbs ./113 kg—Dual Point or Strut-Mounted Load: 350lbs ./158 kg. Apply STR-04 s lotted s teel s trut channel under heavy loads over 250lbs .

Spacing Space Blox approixmately every 7 feet a long a l l piping.PipeFastening

Screw indents guide fastening screws into specia l internal engineered thread grippingFastening feature. #10 sheet meta l screws recommended. Blox suppl ied with 3/4" ga lvanizeduniversa l quick clamping s trap for up to 2" pipe. Top surface eas i ly adapts to a l l types ofpiping clamps, cl ips , s lotted s trut and 3/8" or 1/2" threaded rod. Al l pipe fastening andadjustments done from top s ide only.

Accessories 1-1/2" Polypropylene top height extender, 10" s lotted s teel s trut, 12" threadedrod, pipe rol lers , securing brackets , M-1 adhes ive, and primer for M-1 adhes ive.

Warranty 20 years Roof Top Blox replacement aga inst manufacturer’s defect.Applications Blox engineered to insta l l on flat roof surfaces for supporting gas , condensate or

refrigeration l ines , electrica l conduits , ductwork or roof top walkways andmechanica l equipment. Rated for temperatures up to 200oF/93oC.

Roof Top Blox Product Specifications

Suggested Engineering Specification

Products Available

Roof top support blocks for gas piping, plumbing, HVAC, conduit, cable tray, and mechanica l equipment sha l l be Roof Top Blox (RTB-01). The support blocks must be des igned to el iminate roof penetrations , flashings or damage to roofing membrane. Support body shal l be made of recycled UV-res is tant Polypropylene Copolymer. Base platform materia l sha l l be 1” thick, 25ps i , type 4 closed cel l s tructura l foam to dis tribute and evenly cushion loads . Support top surface sha l l have molded in pipe organizing saddles and strut mounting cradle. The top surface sha l l a lso have screw guide indents and engineered internal screw thread gripping feature. Block must accept 3/8” and 1/2” threaded rod (ROD-03) us ing s ide entry nut s lots to a l low fast top s ide assembly and piping height adjustments . Aluminum rol lers (ROL-05 or ROL-06) sha l l be insta l led on long piping runs . Securing brackets (SBC-07) and adhes ive (ADH-12) recommended for permanently securing Blox into i ts fina l insta l led pos i tion, anchoring aga inst wind, ra in and snow loads .

ZdϬϭZŽŽĨdŽƉůŽdž ;/ŶĐůƵĚĞƐĐůĂŵƉŝŶŐƐƚƌĂƉͿďƵŶĚůĞĚŝŶϴ-ƉĂĐŬƚŽƚĞƐ

ydϬϮϭϱ ůŽdž,ĞŝŐŚƚdžƚĞŶƐŝŽŶ &ĂƐƚĞŶƐĚŝƌĞĐƚůLJŽŶƚŽƉŽĨůŽdžǁŝƚŚηϭϬƐĐƌĞǁƐƉƌŽǀŝĚĞĚŽƌĞůĞǀĂƚĞĚǁŝƚŚĞdžƚĞŶƐŝŽŶƌŽĚƐ

ZKϬϯϭϮdžƚĞŶƐŝŽŶZŽĚƐ ;ϮͿϭϮƚŚƌĞĂĚĞĚƌŽĚƐ;ϴͿŶƵƚƐ ;ϰͿǁĂƐŚĞƌƐnjŝŶĐƉůĂƚĞĚ

^dZϬϰϭϬ'ĂůǀĂŶŝnjĞĚ^ůŽƩĞĚ^ƚĞĞů^ƚƌƵƚŚĂŶŶĞů

ZK>Ϭϱ^ŵĂůůWŝƉĞZŽůůĞƌ ;ĂůƵŵŝŶƵŵͿ^ƵƉƉŽƌƚƐϭƚŽϯƉŝƉĞ

ZK>Ϭϲ>ĂƌŐĞWŝƉĞZŽůůĞƌ ;ĂůƵŵŝŶƵŵͿ^ƵƉƉŽƌƚƐϰƚŽϲƉŝƉĞ;ŝŶĐůƵĚĞƐƐƚƌƵƚΘŵŽƵŶƟŶŐƐĐƌĞǁƐͿ

^Ϭϳ^ĞĐƵƌŝŶŐƌĂĐŬĞƚƐ ;ƉŽůLJĐĂƌďŽŶĂƚĞͿ ;ϮͿďƌĂĐŬĞƚƐƐĞĐƵƌĞůŽdžĚŝƌĞĐƚůLJƚŽƌŽŽĨǁŝƚŚD-ϭĂĚŚĞƐŝǀĞhƐĞďƌĂĐŬĞƚƐĨŽƌǁŝŶĚǁĂƚĞƌĂŶĚƐŶŽǁůŽĂĚĐŽŶĚŝƟŽŶƐ;ůŽdžŶŽƚŝŶĐůƵĚĞĚͿ

,ϭϮD-ϭ^ƚƌƵĐƚƵƌĂůĚŚĞƐŝǀĞ;ŐƌĂLJͿ ,ŝŐŚďŽŶĚĂĚŚĞƐŝǀĞĨŽƌĂůůƌŽŽĨŵĞŵďƌĂŶĞƐLJƐƚĞŵƐƉƉůLJƵŶĚĞƌ^ĞĐƵƌŝŶŐƌĂĐŬĞƚƐ;^ϬϳͿϭϬŽnjƚƵďĞďŽŶĚƐϭϬƉĂŝƌ^ϬϳŽƌϮϬZdϬϭ

WZ/ϭϯWƌŝŵĞƌĨŽƌD-ϭĚŚĞƐŝǀĞ WƌŝŵĞƌƌĞƋƵŝƌĞĚĨŽƌďŽŶĚŝŶŐƚŽdWKƌŽŽĨƐLJƐƚĞŵƐϭƉŝŶƚĐĂŶŝƐĞŶŽƵŐŚƚŽďŽŶĚϯϱƉĂŝƌƐŽĨ^ϬϳďƌĂĐŬĞƚƐ

ZdϬϭZŽŽĨdŽƉůŽdžhŶŝƚ

ϰ-ϭϮ

ϴ-ϳϴ

ϴ-ϳϴ

ydϬϮ ϭ-ϭϮ

ƌŽŽŌŽƉďůŽdžĐŽŵ

ϱϬϬŝƐƚƌŝďƵƟŽŶWĂƌŬǁĂLJ ŽůůŝĞƌǀŝůůĞdEϯϴϬϭϳ WŚŽŶĞϴϬϬ-ϴϴϴ-ϴϯϭϮ &ĂdžϵϬϭ-ϴϱϯ-ϱϬϬϴ