10Base-T Ethernet Converter
AR-727CM
Table of Contents
1. Introduction 1.1 Features 1.2 Specifications
1.3 Applications 2. Overview
2.1 Dimensions and mounting 2.2 LED Indicators 2.3 DIP Switch Settings 2.4 D-SUB Connector pin out 3. Configuration
3.1 Reset To Factory Default 3.2 DHCP Function
3.3 How to configure the IP address assign 3.3.1 Get IP address by using Net727i so 3.3.2 Get IP address by DHCP Server 3.3.3 Get IP address by Hyper-Terminal
----------------------------------- 1 ----------------------------------- 1 ----------------------------------- 1
----------------------------------- 2 ------------------------------------ 3 ------------------------------------- 3 ------------------------------------ 3
----------------------------------- 4 ----------------------------------- 4 ed to your AR-727CM device 5 ftware ------------------------- 5 ----------------------------------- 8
function of the Window ------- 10 2005/12/16
1. Introduction
The AR-727CM is an Ethernet to Serial Device Communication Controller. It transparently routes the data between Ethernet Port and Serial Port. The Device Server can be used in any application that need Ethernet and with a serial communication port already.
1.1 Features - Support Serial Port Freeze Function for High Security Use - Support Lock Remote IP Function - Provide TCP/IP Server Stack and DHCP function - One asynchronous serial ports allow full-duplex, 8-bit, none parity data
transfers - Serial port hardware handshaking with CTS and RTS selectable - 10BASE-T NE2000 compatible Ethernet Controller - Provide 256 Bytes Serial Buffer and 256 Bytes of TCP Buffer - Auto Configuration of the IP and gateway addresses and subnet function - Watchdog Timer included - Remote Configuration Through Ethernet or Local Configuration via Serial
Port - DIP Switch Selectable for RS-485 or RS-232 Interface
1.2 Specifications
- Ethernet : 10Base-T NE2000 compatible - Serial Port : 2400~57600 bps, None Parity, 8 data, 1 stop bit - Environment : -20°C to +75°C - Power Suppiy (DC) : 9.0 ~ 24.0 VDC - Power Consumption : 1.5W (max) - Dimensions (mm) : 100 X 60 X 23 - Accessories : One DB9 Male Cable for RS-485/RS-232 and
Power - Software and Utility : Net727i Setup Program in Floppy Disk or
CDROM.
1.3 Applications Access Controller, Time Recorder, Industry Controller, etc.
1
2. Overview 2.1 Dimensions and mounting
DIP
-SW
RS-
485
RS-
232
5G
ND
Eth
erne
t Por
t
46
Rx
( Inp
ut )
Tx (
Out
put)
B ( -
)DB9
A (
+ )
3291
OFF
AC
T
RS-
485
RS-
232
RS-
485
RS-
232
DH
CP
Enab
le
RU
N M
ode
Set
up M
ode
Link
Pow
er
AR
-727
CM
OFFON
OFFON2
ON
OFF
OFF1 ON
ON
ON
OFF
ON
3 OFF
4
BU
SY
Ser
ial T
X
Ser
ial R
X
DC
-INS
eria
l Por
t
Pow
er D
C
Pow
er D
C
DH
CP
Dis
able
RES
ET
DIP
-SW
SO
YA
L
How to install:
Screw length must no longer than 6mm.
Remove Jumper if powered by External Adapter. Close Jumper if powered through DB9 (4,6).
2
2.2 LED Indicators AR-727CM’s top panel contains six LED indicators, as described in the following table.
LED Name LED Color LED Function Green Power is on. POWER
Off Power is off, or power error condition exits. Yellow Media is connected. Link
Off Media is not connected. Green 10 Mbps Ethernet connection. ACT
Off Ethernet cable is disconnected, or has a short. Red Configuration Setup. BUSY Off No.
Green Serial data is being received. Serial RX Off Serial data is not being received. Red Serial data is being transmitted. Serial TX Off Serial data is not being transmitted.
2.3 DIP Switch Settings
DIP Switch 1 2 3 4 RS-232 ON OFF
Serial Setup Mode Two Wire RS-485
ONOFF ON
RS-232 ON OFF Normal Run Mode and Networking Setup Two wire RS-485
OFFOFF ON
DHCP Enable (Auto IP Address Configuration) ON DHCP Disable (Auto IP Address Configuration) OFF
2.4 D-SUB Connector pin out
Function Pin Wire Color Type DATA (A +) 1 Blue Bi-direction Two Wire RS-485DATA (B -) 9 Green Bi-direction
Data Transmit 2 White Output Data Receive 3 Yellow Input Signal Ground 5 Brown
Request to send (RTS) 8 Gray Output
RS-232
Clear to Send (CTS) 7 Purple Input Power Source : V+ 6 Red Power Input Power Ground : V- 4 Black
Depend on JP1 Setting
3
AR-727CM has two way of power supply, one from power jack and one from DB9. In general usually, The Serial Device has DC power already, so AR-727CM can share the power with Serial Device. The DB9 pin-4 connect to Power Ground (V-), pin-6 Connect to Power Source (V+). If you power AR-727CM from Adapter, remove the jumper from JP1.
3. Configuration 3.1 Reset To Factory Default
Press RESET button more than 5 seconds, The BUSY LED will flash 5 times, then AR-727CM will restore to Factory Default value. DIPswitch is OFF, OFF, OFF, OFF position.
IP Address : 192.168.001.127 Gateway IP : 192.168.001.254 Subnet Mask : 255.255.255.000 Serial Port : 9600,N,8,1
TCP Port : 1621 Password : none
DIP Switch position
OFF, OFF, OFF, OFF
3.2 DHCP Function
AR-727CM support Auto Configuration of the
IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. Switch DIP SW-4 to “ON” position then power cycle the Device. In begging state the ACT LED will flashing, After IP has got ACT LED will off and auto save the new IP address to EEPROM, Switch DIP SW-4 to “OFF” position and move DIP SW-1 to “ON” position then you can get the new IP from Serial port via Hyper terminal.
4
3.3 How to configure the IP address assigned to your AR-727CM device? 3.3.1 Get IP address by using Net727i software Usually, the network of some company don’t built-in the DHCP Server. Therefore, we can use the following method to get default IP address and modify it. The steps as follows: Step 1: Press RESET button more than 5 seconds, The BUSY LED will flash 5 times,
then AR-727CM will restore to Factory Default value. Step 2 Open explorer, click “My Network Places” and press right key to open Properties.
Ste
:
p 3: Click “Local Area Connection” and press right key to open Properties. Then double click Internet Protocol (TCP/IP) to open Properties.
5
Step 4: Click ”Use the following IP address” and enter IP address 192.168.001.64, Subnet mask 255.255.255.0
Step 5: Click “ok” to exit. Step 6: Install Net727i.exe into your PC and run Net727i.exe
(Start → Programs → soyal software → Net727i )
6
Step 7: Click “Get” to get default Local IP Address, Gateway, Netmask and TCP Port. Step 8: Change new address and parameters then click “write”.
Step 9: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode.
Remark: (1) How to know PC’s IP Address? (Win98)
Start → execute → enter “winipcfg”. (2) How to know PC’s IP Address? (Win2000)
Start → Programs → Accessories → Command Prompt → C:\> ipconfig (3) Please see detailed parameter in next page:
Setting Value Notes NecessityLocal IP Address 192.168.001
.127 Defines own IP Address of the AR-727CM Required
Local Gateway IP Address
192.168.001.254
Defines the IP Address of the default gateway
Required
Local Subnet Mask
255.255.255.000
Defines the IP Address range for the local network segment
Required
TCP Port 1621 The TCP port that other devices must use to contact this device. To avoid conflicts with standard TCP ports.
Required
MAC Address 00.E0.4C.00.00.50
The MAC (Media Access Control) address is a unique identifier set at the factory.
-
Force Transmit time
5 Forces AR-727CM device’s TCP/IP protocol software to try to pack serial data received during the specified time into the same data frame.
Optional
Force Transmit Bytes
32 Defines the amount of data in the serial, Ethernet buffer at which the break condition will be generated and the contents of buffer will be sent out via the Ethernet port.
Optional
Lock Remote IP Address
- Allows contact with only the specified remote IP address.
Optional
Lock Serial Port (Free Run or Freeze Over)
- To avoid the hacker use this IP to intercept data when Remote IP Address doesn’t receive data.
Optional
Setup Password none Console password Optional Serial Port Speed 9600 Changes current baud rate of the
AR-727CM’s serial port (from 2400bps to 57600bps).
Required
TCP Auto Disconnect Time (Second)
60 This device automatically closes TCP connection if there is no TCP activity for the given time.
Optional
Serial Port Hardware Handshaking (RTS/CTS)
- An exchange of signal over specific wires which each device indicates its readiness to send or receive data.
Optional
DHCP - Selecting the enable option allows DHCP to automatically assign the AR-727CM’s IP address.
Optional
7
3.3.2 Get IP address by DHCP Server AR-727CM support Auto Configuration of the IP and gateway addresses and subnet
mask function, but must make sure the DHCP Server is active. The steps as follows: Step 1: Switch DIP Switch position to OFF, OFF, OFF, ON. Step 2: Power cycle the device Step 3: In begging state the ACT LED will flashing, after IP has got ACT LED will off and auto save the new IP address to EEPROM. Step 4: Switch DIP SW-4 to “OFF” position and move DIP SW-1 and SW-2 to “ON” position Step 5:To modify parameter on the AR-727CM through the Hyper-Terminal function of the Window. (Start → Programs → Accessories → Communication → Hyper Terminal) Step 6: Click “Hyper-Terminal”. Step 7: key-in any temporary name. Shown as follows: It is not important matter.
Step 8: Choose which COM port St and click OK to exit.
8
ep 9: Set Port Settings to 9600, 8, None, 1, None and click “OK” to save.
Step 10: AR-727CM already gets IP address now shown as follows: Note that save it after set all parameters.
Step 11: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode.
9
3.3.3 Get IP address by Hyper-Terminal function of the Window Step 1: To get Default IP address on the AR-727CM through the Hyper-Terminal function of the Window. (Start → Programs → Accessories → Communication → Hyper Terminal)
Step 2: Click “Hyper-Terminal”. Step 3: key-in any temporary name.
Shown as follows: It is not important matter.
S
tep 4: Choose which COM port Step and click OK to exit.
10
5: Set Port Settings to 9600, 8, None, 1, None and click “OK” to save.
Step 6: AR-727CM already gets IP address now shown as follows:
Step 7: Please refer above item and enter item on the so that set all parameters.
Step 8: Note that enter item 6 on the to save parameter after finishing to
set parameter.
Step 9: If AR-727CM connects to soyal controller, please switch DIP Switch
position to OFF, OFF, ON, OFF to RS-485 RUN Mode.
11