Post on 18-Mar-2020
transcript
ABOUT STERLITE TECH
We design, build, and manage web-scale networks for the needs of tomorrow
Among the world’s largest integrated manufacturers of glass preform, optical fibre, optical fibre cables, and data cables
Leader in system and network integration, with an extremely strong partner ecosystem
Key player in OSS and BSS solutions, powering next-generation telecom software. Recognised as ‘visionary’ in Gartner’s Magic Quadrant
We partner with global service providers, large enterprises, and governments
Optical CommunicationPRODUCTS
System IntegrationSERVICES
Telecom SOFTWARE
The Indian government to enable the world’s largest digital inclusion by connecting 2,50,000 villages
Eight of the top 10 global telco service providers for optical fibre networks
The Indian defence to build the world’s largest intrusion-proof network
Smart cities to design, build, and manage networks to enable citizen services
We partner with:
GLOBAL SERVICEPROVIDERS SMART CITIES
RURALBROADBAND
LARGE ENTERPRISESe.g. DEFENCE
I
We are a global MNC, with presence in over 100 countries
We are the only company in the world to have an integrated silicon-to-software capability
Sterlite Tech is backward integrated to manufacture optical fibre from sand, and forward integrated to offer broadband services and telecom software
II
We have among the world’s largest integrated manufacturing facilities for optical fibre and optical fibre cable
Among the top three integrated players globally, with optical fibre capacity expansion from 30 mn fibre km to 50 mn fibre km
Core research on optical fibre for high-speed
connectivity
Technology and applied research on smarter
networks of the future
Training for deployment of future-ready communication
networks
Facilities in INDIA,
CHINA and BRAZIL
III
Ordering Customized Fibre Optic Cable
a) What grade of fibre is required?Different fibre grades are recommended based on use cases – for example, for FTTH A2 bend insensitive fibre is recommended due to minimal loss at bend points. To specify the fibre type you need, use the first two digits from optical fibre cable catalogue ID system.
b) What is the total fibre count and fiber count per tube or per module?Total fibre count and fibre count per tube are decidedon the basis of the network architecture and number of drop points. Refer to digits 3-6 to specify the total fibre count and digits 9-11 to specify the fibre count per tube from optical fibre cable catalogue ID system.
c) What kind of buffer structure and installation is required?Cable is also recommended on the basis of the terrain where it will be laid. Specify the physical robustness of the cable using digit 7 for installation and digit 8 for buffer structure from optical fibre cable catalogue ID system.
Note: Along with the cable architecture, specify the physical properties using digits 12-17 from the optical fibre cable catalogue ID system described on the following page.
We offer a standard set of fibre optic cables for different applications, and these are available for quick delivery to customers. However, if you require cables not available under our standard set, we will design and deliver them as per your specifications.If you want to order customized fibre optic cable, you’ll need to share the following information with us.
IV
Fibre Optic Cable Catalogue ID System
Architecture
2d
1-2
D M 012
7 8 9-11
0072
3-6
Property
X
12
R D
15 16
-
13
F
14
E
17
1-2 -> Fibre Grade
2d – G652D
a1 – G657a1
a2 – G657a2
b3 – G657b3
55 – G655
56 – G556
M1 – OM1
M2 – OM2
M3 – OM3
M4 – OM4
3-6 -> Fibre Count
0001
0002
0004
0006
0008
0012
0024
0036
0048
0096
0144
0288
0432
0576
0720
0864
1152
7 -> Installation
D – Duct
B – Direct Burial
A – Aerial Self Support
8 – Aerial Figure 8
R – Drop/ Rise
8 - > Buffer Structure
L – Loose Tube
R – Ribbon Tube
T – Tight Buffer Tube
M – Micro Module Tube
9-11 -> Fibre per Tube
01
02
04
06
08
12
24
36
48
96
144
14-> Armoring
G –Glass Roving Yarns
F- FRP
M – Mica Tape
T – Steel Tape
A – Aluminum Tape
W – Steel Wire
– No Armoring
13 -> Fire Retarded (F) / -
12 -> Water ProtectionX – Wet DryD – Dry DryW – Wet Wet– No Water ProtectionWet Dry – 1st is for within tube and 2nd is for between
15 -> Rodent Resistant (R) / -
16 -> JacketingS – Single JacketD – Dual JacketT – Triple Jacket
17 -> Easy Pull (E) / -
In this brochure, every catalogue ID represents a family of fibre optic cable. By varying the green colored characters different cables of the same family can be represented. For example “Ribbon Lite Unitube Single Jacket Steel Tape Armored
2d0144:BR144:W-TRS-
2d0048:BR048:W-TRS-
2d0072:BR072:W-TRS-
2d0096:BR096:W-TRS-
2d0144:BR144:W-TRS
V
EXAMPLE – 2d0072: DM012: X-FRDE
2d-72 fibres,In duct Micro Module 12 fibres per tube,Wet-Dry FRP Armored Rodent Resistant Dual Jacket Easy Pull
VI
Table of Contents
Sl.No. PRoDUCT FAMIlY CATAloGUE ID PG. No.
1. OutdOOr ribbOn Fibre Optic cable
1.1 RIBBoN-lITE® Multitube Single Jacket 2d1152:DR144:X---S- 1
1.2 RIBBoN-lITE® Multitube Single Jacket Steel Tape Armored 2d1152:BR144:X-TRS- 3
1.3 RIBBoN-lITE® Gel Free Multitube Single Jacket 2d0864:DR144:D---S- 5
1.4 RIBBoN-lITE® Multitube Single Jacket ADSS 2d0288:AR048:X---S- 7
1.5 RIBBoN-lITE® Gel Free Unitube Single Jacket 2d0144:DR144:D---S- 9
1.6 RIBBoN-lITE® Unitube Single Jacket 2d0144:DR144:W---S- 11
1.7 RIBBoN-lITE® Unitube Single Jacket Steel Tape Armored 2d0144:BR144:W-TRS- 13
2. YOgalite Fibre Optic cable
2.1 Yogalite™ Single Jacket Duct for Access Networks 2d0864:DM012:X---SE 16
2.2 Yogalite™ Single Jacket overhead for Access Networks 2d0144:DM012:X---SE 19
2.3 Yogalite™ Single Jacket for Transport Networks 2d0288:DM012:X---SE 22
2.4 Yogalite™ Double Jacket Direct Buried for Transport Networks 2d0144:BM012:X-GRDE 24
2.5 Yogalite™ Double Jacket FRP Armored for Transport Networks 2d0144:DM012:X-FRDE 26
2.6 Yogalite™ for Access Networks Adapted for Midspan Access 2d0144:DM012:X---SE 28
2.7 Yogalite™ Single Jacket for Indoor/outdoor Distribution 2d0144:DM012:XF--SE 31
2.8 Yogalite™ Single Jacket for Indoor Riser Installations a20144:RM012:XF--SE 33
3. OutdOOr FttX Fibre Optic cable
3.1 Indicium lite™ Retractable a10048:Dl002:----SE 36
3.2 Atlas lite™ Airblown 2d0024:DM024:W---S- 38
3.3 DUCT-lITE® Unitube Single Jacket Nano Duct 2d0024:Dl024:W---S- 40
3.4 AERIAl-lITE® Unitube Figure- 8 2d0012:8l012:W---S- 42
3.5 ARMoR-lITE® Unitube Single Jacket Steel Tape Armored 2d0024:Bl024:W-TRS- 44
3.6 ARMoR-lITE® Unitube Single Jacket Steel Wire Armored 2d0024:Bl024:W-WRS- 46
3.7 DRoP lITE Unitube Mini ADSS 2d0024:Al024:W---S- 48
3.8 DRoP-lITE Easy Strip Fig 8 Flat a10002:8T002:-F--SE 50
3.9 DRoP-lITE Flat Drop Dielectric/Toneable 2d0012:Rl012:W-WRS- 52
3.10 DRoP lITE Unitube Single Jacket Embedded Strength Member 2d0024:Rl024:W---SE 54
3.11 DRoP lITE Unitube Single Jacket Dielectric Armored 2d0024:Rl024:W-GRSE 56
3.12 DRoP-lITE Unitube Single Jacket Miniature 2d0024:Rl024:W---S- 58
3.13 Simplex Armored 2d0002:BT002:--TRSE 60
3.14 Double Jacket Tight Buffer a10001:DT001:-F--DE 62
4. indOOr FttX Fibre Optic cable
4.1 Simplex / Zip Duplex a10002:RT002:----SE 64
4.2 Tight Buffer Riser a10024:RT024:-F--SE 66
4.3 Mini Breakout a10024:DT024:-F--SE 68
4.4 Easy Strip Flat a10002:DT002:-F--SE 70
5. SpecialtY Fibre Optic cable
5.1 olympus lite™ Fire Resistant 2d0048:Bl048:WFTRD- 73
5.2 All Terrian Intrusion Protection 2d0056:DR056:W---D- 75
5.3 Tactical Unarmored 2d0008:DT008:----S- 77
5.4 Tactical Armored 2d0004:Dl004:W-WRS- 79
5.5 Micro-lITE Multitube Single Jacket 2d0288:Dl036:X---SE 81
5.6 Composite Cable for Remote Powering & Data - 83
5.7 Composite Cable (Fibre+lAN) - 85
5.8 Work Safe Aerial a10048:AM048:X---SE 87
6. OutdOOr aerial Fibre Optic cable
6.1 AERIAl-lITE® Multitube Single Jacket ADSS 2d0144:Al012:X---S- 90
6.2 AERIAl-lITE Multitube Double Jacket ADSS 2d0144:Al012:X---D- 92
6.3 AERIAl-lITE® Gel Free Multitube Single Jacket ADSS 2d0144:Al012:D---S- 94
6.4 AERIAl-lITE® Multitube Single Jacket Figure- 8 2d0144:8l012:X---S- 96
7. OutdOOr undergrOund Fibre Optic cable
7.1 DUCT-lITE® Multitube Single Jacket 2d0864:Dl024:X---S- 99
7.2 ARMoR-lITE® Multitube Double Jacket Dielectric Armored 2d0864:Bl024:X-GRD- 101
7.3 ARMoR-lITE® Multitube Single Jacket Steel Tape Armored 2d0864:Bl024:X-TRS- 103
7.4 ARMoR-lITE® Multitube Double Jacket Steel Tape Armored 2d0864:Bl024:X-TRD- 105
7.5 ARMoR-lITE® Multitube Double Jacket Steel Wire Armored 2d0144:Bl012:X-WRD- 107
7.6 DUCT-lITE® Gel free Multitube Single Jacket 2d0288:Dl012:D---S- 109
7.7 ARMoR-lITE® Gel free Multitube Single Jacket Steel Tape Armored 2d0288:Bl012:D-TRS- 111
7.8 ARMoR-lITE® Multitube Double Jacket FRP Armored 2d0144:Bl012:X-FRD- 113
Table of Contents
VII
Sl.No. PRoDUCT FAMIlY CATAloG ID PG. No.
Outdoor Ribbon Fibre Optic Cable
Features & benefits• Available up to 1152 fibre count in either single-mode or
multi-mode optical fibres• These cables have high fibre count leading to more efficient
use of limited duct space• Ribbon cable can be prepared and spliced much more
rapidly• Precise fibre and ribbon geometries result in excellent mass
fusion splicing yields • Fibre ribbons are individually marked for easy identification• These are easy to install due to dry water-blocking design• Multitube design with ripcords for easy and quick mid-span access • Dry water-blocking technology for gel free core helps in quicker end preparation• Easily removable rugged thermoplastic jacket• Flexible, light weight, easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
ribbOn-lite® Multitube Single Jacket 2d1152:dr144:X---S-
typical construction of cableproduct detailsSterlite Tech™ RIBBON- LITE® Multitube Single Jacket Cable combines robust performance for duct installations with the productivity of high-count mass fusion splicing. The optical fibres are arranged into ribbon units by placing the fibres in a flat array of 12 colours-coded fibres bonded together by a UV-curable matrix material. The Ribbon units placed inside robust buffer tubes are stranded around a fibre reinforced plastic (FRP) central strength member. In addition to optical fibres, the buffer tubes contain water blocking gel, and the cable core is surrounded with water-swellable tape to prevent water ingress in the interstices of cable core. The cable core is surrounded with thermoplastic sheath making the cable robust and installation friendly.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an outstanding solution for demanding high-growth, high-bandwidth communications applications like data centers, equipment connections within cabinets, outside plant applications. These cables are basically used in duct installation applications
1. CENTRAL STRENGTH MEMBER2. LOOSE TUBE WITH RIBBONS & GEL3. WS YARNS4. CORE WRAPPING WITH PERIPHERAL STRENGTH YARNS(IF REqUIRED)5. RIPCORD(S)6. OUTER SHEATH
1
2
3
4
5
6
1
8647212
144
26.0
460
3000
2500 N
Mechanical and environmental characteristics*TestMax. Tensile Strength (N)Bending RadiusCrush Resistance (N/100mm)Impact strength (N.m)TorsionDrip TestTemperature Cycling Water Penetration
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E11IEC-60794-1-21-E3IEC-60794-1-21-E4IEC-60794-1-21-E7IEC-60794-1-21-E14IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
25± 180°
30 cm, 70ºC, 24 hr
Dynamic = 20D, Static = 15D
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
Installation: -20ºC to +60ºC
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
72
62
2418.0220
2700
2000N
9682
2418.0
220
2700
2000N
144122
2420.0
270
2700
2000N
288244
4821.0
290
3000
2500 N
432366
7222.0
330
3000
2500 N
11529612
144
32.2
645
3000
2500 N
Specifications
transmission characteristics
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D & G657A2. Refer to specific data sheets for details.
performance StandardsCable Complies to the following main Standards IEC.60794 series, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations, CPR certification for LSZH sheath
physical characteristics
** This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
Fibre Type
G652D**
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0,15
≤ 0,15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drums Lengths (tolerance ±5%): 2km, 4kmNote - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
Fibre CountNo of RibbonRibbon / TubeFibres/ TubeNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
2
ribbOn-lite® Multitube Single Jacket Steel tape armored 2d1152:br144:X-trS-
Features & benefits• Available up to1152 fibre count in either single-mode or
multi-mode optical fibres• These cables have high fibre count leading to more efficient use of limited duct space• Ribbon cable can be prepared and spliced much more rapidly• Precise fibre and ribbon geometries result in excellent mass-fusion splicing yields• Fibre ribbons are individually marked for easy identification • These are easy to install due to dry water-blocking design• Steel tape adds to crush resistance as well as can be used as a cable locator after installation• Multitube design with ripcords for easy and quick mid-span access • Dry water-blocking technology for gel free core helps in quicker end preparation• Easily removable rugged thermoplastic jacket• Easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
typical construction of cableproduct detailsSterlite Tech™ RIBBON-LITE® Multitube Single Jacket Steel tape Armored Cable combines robust performance for duct installations with the productivity of high-count mass fusion splicing. The optical fibres are arranged into ribbon units by placing the fibres in a flat array of 12 colour-coded fibres bonded together by a UV-curable matrix material. The Ribbon units placed inside robust buffer tubes are stranded around a fibre reinforced plastic (FRP) central strength member. In addition to optical fibres, the buffer tubes contain water blocking gel, and the cable core is surrounded with water-swellable tape to prevent water ingress in the interstices of cable core. Corrugated Steel Tape armor surrounds the cable core with thermoplastic jacket placed over the armor layer making the cable robust and installation friendly.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an outstanding solution for demanding high-growth, high-bandwidth communications applications like data centers, equipment connections within cabinets, outside plant applications. These can be used induct or direct buried installation applications.
1. CENTRAL STRENGTH MEMBER2. LOOSE TUBE WITH RIBBONS & GEL3. WS YARNS4. CORRUGATED STEEL TAPE5. RIPCORD(S)6. OUTER SHEATH
1
2
3
4
5
6
3
11529612
14434.0930
3000
3000
Mechanical and environmental characteristics*TestMax. Tensile Strength (N)Bending RadiusCrush Resistance (N/100mm)Impact strength (N.m)TorsionDrip TestTemperature Cycling Water Penetration
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E11IEC-60794-1-21-E3IEC-60794-1-21-E4IEC-60794-1-21-E7IEC-60794-1-21-E14IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
50± 180°
30 cm, 70ºC, 24 hr
Dynamic = 20D, Static = 15D
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
Installation: -20ºC to +60ºC
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
726224
19.5305
3000
3000
9682
2419.5305
3000
3000
144122
2421.8370
3000
3000
288244
4821.8390
3000
3000
432366
7223.5470
8647212
14427.8625
30003000
30003000
Specifications
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D & G657A2. Refer to specific data sheets for details.
performance StandardsCable complies to the following main Standards EC.60794 series, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations,
physical characteristics
** This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km,Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
Fibre Count
No of Ribbon
Ribbon / Tube
Fibres/ Tube
Nominal Cable Diameter (mm) ± 0.5mm
Nominal Cable Weight (kg/km) ± 10%
transmission characteristics
Fibre Type
G652D**
1310nm
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
PMD LDV,ps/√km
≤ 0,15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
4
ribbOn-lite® gel Free Multitube Single Jacket 2d0864:dr144:d---S-
Features & benefits• Available up to 864 fibre count in single mode optical fibre • These cables have high fibre count leading to more efficient use of limited duct space • Ribbon cable can be prepared and spliced much more Rapidly • Precise fibre and ribbon geometries result in excellent mass fusion splicing yields• Fibre ribbons are individually marked for easy identification• These are easy to install due to dry water-blocking design• Multitube design with ripcords for easy and quick mid-span access• Dry water blocking materials inside and outside the tubes enable full water protection• Water blocking yarns inside tubes enable rapid, clean fibre splicing and storage inside the joint enclosures• Easily removable rugged thermoplastic jacket• Flexible, light weight, easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
typical construction of cableproduct detailsSterlite Tech™ RIBBON- LITE® Multitube Single Jacket Cable combines robust performance for duct installations with the productivity of high-count mass fusion splicing. The optical fibres are arranged into ribbon units by placing the fibres ina flat array of 12 colors-coded fibres bonded together by aUV-curable matrix material. The Ribbon units placed insiderobust buffer tubes are stranded around a fibre rein forced plastic (FRP) central strength member In addition to optical fibres, the buffer tubes contain water-swellable tape, and the cable core is surrounded with water-swellable tape to prevent water ingress in the interstices of cable core. The cable core is surrounded with thermoplastic sheath making the cable robust and installation friendly.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an outstanding solution for demanding high-growth, high-bandwidth communications applications like data centers, equipment connections with in cabinets, outside plant applications. These cables are basically used in duct installation applications
1. CENTRAL STRENGTH MEMBER2. LOOSE TUBE WITH RIBBONS & WATER
SWELLABLE TAPE3. WS ELEMENTS4. FILLER5. CORE WRAPPING WITH WATER SWELLABLE6. RIPCORD(S)7. OUTER SHEATH
1
2
3
4
5
6
7
5
Fibre CountNo of RibbonRibbon / TubeFibres/ TubeNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
Test
Max. Tensile Strength (N)
Bending Radius
Crush Resistance (N/100mm)
Impact strength (N.m)
Torsion
Drip Test
Temperature Cycling
Water Penetration
Standard / Notes
IEC-60794-1-21-E1
IEC-60794-1-21-E11
IEC-60794-1-21-E3
IEC-60794-1-21-E4
IEC-60794-1-21-E7
IEC-60794-1-21-E14
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
Dynamic = 20D, Static = 15D
25
21618336
20.0240
288244
4820.0245
432366
7223.0310
576488
9625.0400
8647212
14427.6420
Specifications
transmission characteristics
Fibre Standard colour code (as per eia/tia 598)
tube Standard colour code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D. Refer to specific data sheets for details.
performance StandardsCable complies to the latest issue of following main Standards IEC.60794 series, ANSI/ICEA S-87-640, TelcordiaGR-20, ITU-T Recommendations
physical characteristics
2700 2700 2700 2700 2700
2000 2000 2000 2500 2500
± 180°30 cm, 70ºC, 24 hr
1m water head, 3m samples, 24 hrs no water leakage
Installation: -20ºC to +60ºC Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
** This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
Fibre Type
G652D**
G6527A1
1310ON
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550ON
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625ON
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0,15
≤ 0,15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Mechanical and environmental characteristics*
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km, 4kmNote - Customized drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
6
ribbOn-lite® Multitube Single Jacket adSS 2d0288:ar048:X---S-
Features & benefits• Available up to 288 fibre count in either single-mode or multi-mode optical fibres• These cables have high fibre count leading to more efficient use of limited duct space or aerial use• Anti-tracking PE can be used for installation in the proximity of high tension power lines (Optional)• This cable can be designed to suit specific requirements of span length, wind speed and other loading conditions• Ribbon cable can be prepared and spliced much more rapidly• Precise fibre and ribbon geometries result in excellent mass-fusion splicing yields • Fibre ribbons are individually marked for easy identification • These are easy to install due to dry water-blocking design• Multitube design with ripcords for easy and quick mid-span access • Dry water-blocking technology for gel free core helps in
quicker end preparation• Easily removable rugged thermoplastic jacket• Flexible, light weight, easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
typical construction of cableproduct detailsSterlite Tech™ RIBBON- LITE® Multitube Single Jacket ADSS Cable combines robust performance for duct installations with the productivity of high-count mass fusion splicing. The optical fibres are arranged into ribbon units by placing the fibres in a flat array of 12 colour-coded fibres bonded together by a UV-curable matrix material. The Ribbon units placed inside robust buffer tubes are stranded around a fibre reinforced plastic (FRP) central strength member. In addition to optical fibres, the buffer tubes contain water blocking gel, and the cable core is surrounded with water-swellable tape to prevent water ingress in the interstices of cable core. High strength aramid yarns are evenly distributed over the core to provide the required tensile strength for aerial self-supporting applications. An overall thermoplastic jacket provides the cable with both mechanical and environmental protection.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an outstanding solution for demanding high-growth, high-bandwidth communications applications like data centers, equipment connections within cabinets, outside plant applications. These cables are used in aerial applications for short to medium span-lengths including deployment along existing aerial Right of Way and electric transmission towers.This cable is suitable for aerial-to-duct /underground transitions.
1. CENTRAL STRENGTH MEMBER2. LOOSE TUBE WITH RIBBONS & GEL3. WS YARNS4. CORE WRAPPING WITH PERIPHERAL STRENGTH
MEMBERS (ARAMID YARNS)5. RIPCORD(S)6. OUTER SHEATH
1
2
3
4
5
6
7
Mechanical and environmental characteristics*TestNESC Conditions/Span
Maximum Operating TensionMaximum Allowable TensionInstallation Sag %Bending RadiusCrush Resistance (N/100mm)Impact strength (N.m)TorsionTemperature Cycling Water Penetration
Standard / Notes
IEC-60794-1-21-E1IEC-60794-1-21-E1
IEC-60794-1-21-E11IEC-60794-1-21-E3IEC-60794-1-21-E4IEC-60794-1-21-E7IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
25± 180°
Dynamic = 25D, Static = 20D1%
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
Installation: -20ºC to +60ºC
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
9682
2418.0237
NESC Light/100 mNESC Medium/ 80 mNESC Heavy/ 50 m
6000
12000
2000 2000 2000
NESC Light/100 mNESC Medium/ 80 mNESC Heavy/ 50 m
6000
12000
NESC Light/100 mNESC Medium/ 80 mNESC Heavy/ 50 m
6000
12000
144122
2420.0280
288244
48200285
Specifications
transmission characteristics
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D. Refer to specific data sheets for details.
performance StandardsCable complies to the following main Standards IEC.60794 series, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations,
physical characteristics
** This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
Fibre Type
G652D**
1310nm
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
PMD LDVps/√km
≤ 0,10
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
Fibre CountNo of RibbonRibbon / TubeFibres/ TubeNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
8
ribbOn-lite® gel Free unitube Single Jacket 2d0144:dr144:d---S-
Features & benefits• Available up to 144 fibre count in single mode optical fibre• These cables have high fibre count leading to more efficient
use of limited duct space• Ribbon cable can be prepared and spliced much more rapidly• Precise fibre and ribbon geometries result in excellent mass-fusion splicing yields• Fibre ribbons are individually marked for easy identification• These are easy to install due to dry water-blocking design• Dry water blocking materials inside and outside the tubes enable full water protection• Water blocking elements inside tubes enable rapid, clean fibre splicing and storage inside the joint enclosures• Easily removable rugged thermoplastic jacket• Flexible, light weight, easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
typical construction of cableproduct detailsSterlite Tech™ RIBBON-LITE® Gel Free Unitube Single JacketCable combines robust performance for duct installations with the productivity of high-count massfusion splicing. The optical fibres are arranged into ribbon units by placing the fibres in a flat array of 12 color-coded fibres bonded together by a UV-curable matrix material. In addition to optical fibres, the buffer tubes contain water-swellable tape to prevent water in gress inside the tube. The loose-tube is surrounded with water-swellable tape to protect against moisture ingress, and anti-buckling strength members are provided in form of two diagonally opposite strength members embedded inside the thermoplastic outer sheath.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an out standing solution for demanding high-growth, high bandwidth communications applications like campus,building, data centers, and equipment connections with in cabinets, premise and outside plant applications.They allow OSP applications to flow seamlessly indoors,using a single cable and no splices.
1. LOOSE TUBE WITH RIBBONS & WATER BLOCKING TAPE2. EMBEDDED STRENGTH MEMBERS3. WATER SWELLABLE TAPE4. RIPCORD(S)5. OUTER SHEATH
1
2
3
4
5
9
TestMax. Tensile Strength (N)Bending RadiusCrush Resistance (N/100mm)Impact strength (N.m)TorsionDrip TestTemperature CyclingWater Penetration
484
1212.097
726
1212.5100
968
1213.0107
1441212
14.5165
Fibre CountNo of RibbonFibres/ RibbonNominal Cable Diameter (mm) ± 1.0 mmNominal Cable Weight (kg/km) ± 10%
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E11IEC-60794-1-21-E3IEC-60794-1-21-E4IEC-60794-1-21-E7IEC-60794-1-21-E14IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
Dynamic = 25D, Static = 20D
25
1m water head, 3m samples, 24 hrs. no water leakage
± 180°
30 cm, 70ºC, 24 hr
Specifications
transmission characteristics
Fibre Standard colour code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D. Refer to specific data sheets for details.
performance StandardsCable complies to the latest issue of following main Standards IEC.60794 series, ANSI/ICEA S-87-640, TelcordiaGR-20, ITU-T Recommendations
physical characteristics
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
* This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
Fibre Type
G652D**
G657A1
1310ON
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550ON
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625ON
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDV,ps/√km
≤ 0,15
≤ 0,15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Mechanical and environmental characteristics*
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2kmNote - Customized drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
Installation: -20ºC to +60ºC Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
2700 2700 2700 2700
2200 2200 2200 2200
10
ribbOn-lite® unitube Single Jacket 2d0144:dr144:W---S-
Features & benefits• Available up to 144 fibre count in either single-mode or multi-mode optical fibres• These cables have high fibre count leading to more efficient use of limited duct space• Ribbon cable can be prepared and spliced much more rapidly• Precise fibre and ribbon geometries result in excellent mass-fusion splicing yields • Fibre ribbons are individually marked for easy identification • These are easy to install due to dry water-blocking design• Dry water-blocking technology for gel free core helps in quicker end preparation• Easily removable rugged thermoplastic jacket• Flexible, light weight, easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
typical construction of cableproduct detailsSterlite Tech™ RIBBON-LITE® Unitube Single Jacket Cable combines robust performance for duct installations with the productivity of high-count mass fusion splicing. The optical fibres are arranged into ribbon units by placing the fibres in a flat array of 12 color-coded fibres bonded together by a UV-curable matrix material. Embedded strength members along with the loose tube surrounded with dry water-swellable elements to prevent from longitudinal water ingress is covered with UV Stabilised PE sheath which makes the cable installation friendly.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an outstanding solution for demanding high-growth, high-bandwidth communications applications like campus, building, data centers, and equipment connections within cabinets, premise and outside plant applications. They allow OSP applications to flow seamlessly indoors, using a single cable and no splices.
1. LOOSE TUBE WITH RIBBONS & GEL2. WATER SWELLABLE TAPE3. EMBEDDED STRENGTH MEMBER4. RIPCORD(S)5. OUTER SHEATH
1
2
3
4
5
11
Mechanical and environmental characteristics*TestMax. Tensile Strength (N)Bending RadiusCrush Resistance (N/100mm)Impact strength (N.m)TorsionDrip TestTemperature Cycling Water Penetration
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E11IEC-60794-1-21-E3IEC-60794-1-21-E4IEC-60794-1-21-E7IEC-60794-1-21-E14IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
25
± 180°
Dynamic = 25D, Static = 20D
1%
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
Installation: -20ºC to +60ºC 1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
484
1211.6130
2000
2000
726
1212.4145
2000
2000
968
1212.8150
2000
2000
1441212
14.0175
2000
2000
Specifications
transmission characteristics
Fibre Standard colour code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D. Refer to specific data sheets for details.
performance StandardsCable complies to the latest issue of following main Standards IEC.60794 series, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
physical characteristics
** This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
Fibre Type
G652D**
1310nm
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
PMD LDVps/√km
≤ 0,15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drums Lengths (tolerance ±5%): 2km, 4kmNote - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
Fibre CountNo of RibbonFibres/ RibbonNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
12
ribbOn-lite® unitube Single Jacket Steel tape armored2d0144:br144:W-trS-
Features & benefits• Available up to 144 fibre count in either single-mode or multi-mode optical fibres• These cables have high fibre count leading to more efficient use of limited duct space• Ribbon cable can be prepared and spliced much more rapidly• Precise fibre and ribbon geometries result in excellent mass-fusion splicing yields • Fibre ribbons are individually marked for easy identification • These are easy to install due to dry water-blocking design• Steel tape adds to crush resistance as well as can be used as a cable locator after installation• Dry water-blocking technology for gel free core helps in quicker end preparation• Easily removable rugged thermoplastic jacket• Flexible, light weight, easy to handle & install• Tensile and crush resistant• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
typical construction of cableproduct detailsSterlite Tech™ RIBBON-LITE® Unitube Single Jacket Steel Tape Armored Cable combines robust performance for duct as well as direct installations with the productivity of high-count mass fusion splicing. The optical fibres are arranged into ribbon units by placing the fibres in a flat array of 12 colour-coded fibres bonded together by a UV-curable matrix material. Embedded strength members along with the loose tube surrounded with dry water-swellable elements to prevent from longitudinal water ingress Corrugated Steel Tape armor surrounds the cable core with thermoplastic jacket placed over the armor layer making the cable robust and installation friendly.
product applicationRibbon cable design meets the application which requires delivering the highest fibre density in the most compact cable package possible. This cable offers an outstanding solution for demanding high-growth, high-bandwidth communications applications like campus, building, data centers, and equipment connections within cabinets, premise and outside plant applications. These allow OSP applications to flow seamlessly indoors, using a single cable and no splices.
1. LOOSE TUBE WITH RIBBONS & GEL2. CORRUGATED STEEL TAPE3. EMBEDDED STRENGTH MEMBER4. RIPCORD(S)5. OUTER SHEATH
1
2
3
4
5
13
Mechanical and environmental characteristics*TestMax. Tensile Strength (N)Bending RadiusCrush Resistance (N/100mm)Impact strength (N.m)TorsionDrip TestTemperature Cycling Water Penetration
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E11IEC-60794-1-21-E3IEC-60794-1-21-E4IEC-60794-1-21-E7IEC-60794-1-21-E14IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Product Performance
25
± 180°
Dynamic = 25D, Static = 20D
30 cm, 70ºC, 24 hr
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
Installation: -20ºC to +60ºC 1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
484
1213.5145
2000
2000
726
1213.8150
2000
2000
968
1214.2160
2000
2000
1441212
15.5185
2000
2000
Specifications
transmission characteristics
Fibre Standard colour code (as per eia/tia 598)
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D. Refer to specific data sheets for details.
performance StandardsCable complies to the following main Standards IEC.60794 series, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
physical characteristics
** This fibre is also available as a bend insensitive (Sterlite Tech’s NOVA fibre)
Fibre Type
G652D**
1310nm
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0,20
PMD LDVps/√km
≤ 0,15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km, 4kmNote - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
Fibre CountNo of RibbonFibres/ RibbonNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
14
Yogalite Fibre Optic Cable
2
1
3
4
5
6
7
2
1
3
4
5
6
7
Yogalite™ Single Jacket duct for access networks2d0864:dM012:X---Se
typical construction of cableproduct detailsYogaLite™ Single Jacket Duct Cable by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in duct scenarios. The micro-module unit consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress, and are constrained in a thermoplastic sheath, which is provided with embedded strength members to protect from buckling.
product applicationThe YogaLite™ Single Jacket Fibre Optic Cable is intended for external use. The universal design is suited for use in most network arenas, including backbone, access and distribution. The compact micro-module construction with fibre counts ranging from 6 to 864 fibres offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.The cables are ideally suited to installation within ducts using blown on pulling techniques.
Features & benefits• Available in Fibre types SM G652D Nova, G657.A2.
Other fibre options in either single-mode or multi-mode optical fibres are available upon request
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material
• Diametrically opposed embedded strength members
1. EMBEDDED STRENGTH MEMBERS2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. RIPCORD(S)5. WS YARNS6. SEMI DRY MICROMODULES WITH FIBRES7. OUTER SHEATH
provides excellent crush protection performance• Fibre micro-modules are kink resistant and easily removed without the need for tools• Fast and easy midspan access• Ultra-compactness, easier storage and faster installation• Longitudinal moisture protection is enabled by water blocking compounds in tube and core• UV protected• Tightly controlled physical parameters• Combination of fibre types available on request
6F to 576F
720F to 864F
16
Patent numbersl201621036746l EP 16161137.1l EP 16161152.0l IN 2208/MUM/2015
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)Torsion
Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)Torsion
Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
Mechanical and environmental characteristics*
Mechanical and environmental characteristics
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10IEC-60794-1-21-E7
IEC 60794-1-2 1- E3
IEC-60794-1-22-F1IEC-60794-1-22-F5B
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10IEC-60794-1-21-E7
IEC 60794-1-2 1- E3
IEC-60794-1-22-F1IEC-60794-1-22-F5B
** After the test, the change in attenuation shall be ≤ 0.05 dB/km.No damage or crack on cable & no fibre break.
** After the test, the change in attenuation shall be ≤ 0.05 dB/km.No damage or crack on cable & no fibre break.
12
1
6.5
33
6
1
6
33
80
6030
80
6030
100
8545
100
8545
160
10050
220
120
60
220
120
60
270
14070
280
17085
300
19095
350
200100
400
220110
24
2
7.4
42
12
2
7.0
40
100
8545
100
8545
160
10050
220
12060
220
12060
270
14070
2801020017085
48
4
8.5
50
24
4
8.0
45
72
6
9.5
70
48
8
9.0
56
96
8
10.5
82
72
12
10.0
75
144
12
11.5
94
96
16
11.0
92
144
24
12.0
105
288
48
15.0
165
288
24
13.5
140
432
36
15.5
180
576
48
17.0
210
720
60
18.2
245
864
72
19.5
275
Specifications 12F/Module
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
physical characteristics
physical characteristics
Fibre Count
Number of Fibres in Each Micromodules
Number of Micromodule in each cable
Nominal Cable Diameter (mm) ± 0.5mm
Nominal Cable Weight (kg/km) ± 10%
Fibre Count
Number of Fibres in Each Micromodules
Number of Micromodule in each cable
Nominal Diameter (mm) + 0.5mm
Nominal Weight (kg/km) + 10%
Installation: -5ºC to +45ºC Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
Installation: -5ºC to +45ºC Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
1m water head, 3m samples, 24 hrs no water leakage
1m water head, 3m samples, 24 hrs no water leakage
5
2025
2540
±180°/m, L=40N
±180°/m, L=40N
±180°/m, L=60N
±180°/m, L=60N
±180°/m, L=60N
±180°/m, L=120N
±180°/m, L=120N
10150 200
Product Performance
Product Performance
5
2025
2540
150
12
6
6F/Module
Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D andITU-T G.657A2. Refer to specific data sheets for details.
17
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
* For more than 12 modules, single or double or triple or four stripes marking are done as per EIA/TIA 598.
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
18
Yogalite™ Single Jacket Overhead for access networks 2d0144:dM012:X---Se
typical construction of cableproduct detailsYogaLite™ Single Jacket Duct Cable by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in ducts or overhead scenarios. The micro-module unit consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress and are constrained in a thermoplastic sheath which is provided with embedded strength members to protect from buckling.
product applicationThe YogaLite™ Single Jacket Fibre Optic Cable is intended for external use only. The universal design is suited for use in most network arenas, including backbone, access and distribution. The compact micro-module construction with fibre counts ranging from 6 to 144 fibres enables offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.The cables are ideally suited to installation within ducts using blown on pulling techniques; also for overhead scenarios such as lashed or short length unsupported spans
Features & benefits• Available in Fibre types SM G652D Nova, G657.A2.
Other fibre options in either single-mode or multi-mode optical fibres are available upon request.
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material.
• Diametrically opposed embedded strength membersprovides excellent crush protection performance.
• Fibre micro-modules are kink resistant and easilyremoved without the need for tools.
• Fast and easy midspan access.• Ultra-compactness, easier storage and faster
installation.• Longitudinal moisture protection is enabled by water
blocking compounds in tube and core.• UV protected.• Tightly controlled physical parameters.• Combination of fibre types available on request
1. EMBEDDED STRENGTH MEMBERS2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. RIPCORD(S)5. WS YARNS6. SEMI DRY MICROMODULES WITH FIBRES7. OUTER SHEATH
6F to 144F
2
1
3
4
5
6
7
19
120Product Performance
Product Performance
16.031
1630
150
150
150 200
200
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10
IEC-60794-1-21-E7
IEC 60794-1-21- E3
IEC 60794-1-21- E19
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10
IEC-60794-1-21-E7
IEC 60794-1-21- E3
IEC 60794-1-21- E19
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
Specifications 12F/Module
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)
Torsion
Max Crushing resistance (daN/cm)
Aeolian vibrations (Waves)
Resistance of anchor clamps
Temperature Cycling
Water Penetration
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)
Torsion
Max Crushing resistance (daN/cm)
Aeolian vibrations (Waves)
Resistance of anchor clamps
Temperature Cycling
Water Penetration
12
6
5
5
±180°/m, L=40N
±180°/m, L=40N
±180°/m, L=100N
±180°/m, L=60N
2030
2025
10
10
3
3
Installation: -5ºC to +45ºC
Installation: -5ºC to +45ºC
1m water head, 3m samples, 24 hrs no water leakage
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC
Operation: -30ºC to +70ºC
Storage: -40ºC to +70ºC
Storage: -40ºC to +70ºC
3040
2535
10
10
12
6
80
80
80
80
6030
6030
24
12
100
24
170
120
100
27.545
27.047
8040
8040
48
48
270
220
220
170
48.569
89.080
48.055
12060
9045
72
72
270
220
220
270 270
69.577
1210.088
12060
9045
11055
96
96
320
270
270
320
810.586
1611.0100
13565
13062
144
144
320
270
270
320
1211.598
2412.0116
13565
13062
physical characteristics
physical characteristics
Mechanical and environmental characteristics
Mechanical and environmental characteristics
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
6F/Module
20
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
* For more than 12 modules, single or double stripes marking are done as per EIA/TIA 598.
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
21
Yogalite™ Single Jacket for transport networks 2d0288:dM012:X---Se
typical construction of cableproduct detailsYogaLite™ Single Jacket Duct Cable for Transport Networks by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in ducts scenarios. The micro-module unit consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress and are constrained in a thermoplastic sheath which is provided with embedded strength members to protect from buckling.
product applicationThe YogaLite™ Single Jacket Fibre Optic Cable is intended for external use only. The universal design is suited for use for transport networks. The compact micro-module construction with fibre counts ranging from 12 to 288 fibres enables offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.The cables are ideally suited to installation within ducts using blown on pulling techniques
Features & benefits• Available in Fibre types SM G652D Nova, G657.A2.
Other fibre options in either Single-mode or multi-mode optical fibres are available upon request.
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material.
• Diametrically opposed embedded strength membersprovides excellent crush protection performance.
• Fibre micro-modules are kink resistant and easilyremoved without the need for tools.
• Fast and easy midspan access.• Ultra-compactness, easier storage and faster
installation.• Longitudinal moisture protection is enabled by water
blocking compounds in tube and core.• UV protected.• Tightly controlled physical parameters.• Combination of fibre types available on request
1. EMBEDDED STRENGTH MEMBERS2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. RIPCORD(S)5. WS YARNS6. SEMI DRY MICROMODULES WITH FIBRES7. OUTER SHEATH
12F to 288F
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
2
1
3
4
5
6
7
22
16080
12060
Product Performance
17.651
220 220 220 220 270 270
14070
300
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10
IEC-60794-1-21-E7
IEC 60794-1-21- E3
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Specifications 12F/Module
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)
Torsion
Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
12
5
±180°/m, L=100N
±180°/m, L=200N
2025
Installation: -5ºC to +45ºC
1m water head, 3m samples, 24 hrs no water leakage Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
2540
12
9045
24
29.063
11055
48 72
49.569
610.077
12060
96
810.686
144
1211.6102
14070
288
350
2413.8140
physical characteristics
Mechanical and environmental characteristics
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
* For more than 12 modules, single or double stripes marking are done as per EIA/TIA 598.
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
23
Yogalite™ double Jacket direct buried for transport networks 2d0144:bM012:X-grde
typical construction of cableproduct detailsYogaLite™ Double Jacket Direct Buried Cable by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in underground installations. The micro-module unit consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress and are constrained in a thermoplastic sheath which is provided with embedded strength members to protect from buckling. Glass roving yarns are distributed over the inner sheath and an overall polyethylene jacket affords the cable both mechanical and environmental protection.
product applicationThe YogaLite™ double Jacket Fibre Optic Cable is intended for external use only. The universal design is suited for use for direct burial in transport networks. The compact micro-module construction with fibre counts ranging from 12 to 144 fibres enables offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.The cables are ideally suited to installation within ducts using blown or pulling techniques and direct buried using plowing or trenching techniques
Features & benefits• Available in Fibre types SM G652D Nova, G657.A2.
Other fibre options in either single-mode or multi-mode optical fibres are available upon request.
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material.
• Double Jacket and dielectric armoring providesadditional protection against crush and impact and also protects against rodent attacks.
• Diametrically opposed embedded strength membersprovides excellent crush protection performance.
• Fibre micro-modules are kink resistant and easilyremoved without the need for tools.
• Fast and easy midspan access.
1. EMBEDDED STRENGTH MEMBER2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. WS YARNS5. SEMI DRY MICROMODULES WITH FIBRES6. INNER SHEATH7. WBT WITH GLASS YARN8. RIPCORD(S)9. OUTER SHEATH
12F to 144F
• Ultra-compactness, easier storage and faste installation.• Longitudinal moisture protection is enabled by water blocking compounds in tube and core.• UV protected.• Tightly controlled physical parameters.• Combination of fibre types available on request
2
1
3
4
5
6
7
8
9
24
13080
160100
613.6142
814.2155
1215.4178
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
Product Performance
111.298
500
Standard / NotesIEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10
IEC-60794-1-21-E7
IEC 60794-1-21- E3
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Specifications 12F/Module
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)
Torsion
Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
12
±180°/m, L=200N
Installation: -5ºC to +45ºC
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
4555
10
12
200
11070
24
200
212.2113
11070
48
220
412.6123
72
220
13080
96
250
160100
144
250
physical characteristics
Mechanical and environmental characteristics
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
25
2
1
3
4
5
6
7
8
9
Yogalite™ double Jacket Frp armored for transport networks 2d0144:dM012:X-Frde
typical construction of cableproduct detailsYogaLite™ Double Jacket Aerial, duct and direct buried Cable by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in ducts or overhead scenarios. The micro-module unit consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress and are constrained in a thermoplastic sheath which is provided with embedded strength members to protect from buckling.
product applicationThe YogaLite™ double Jacket Fibre Optic Cable is intended for external use only. The universal design is suited for use for multipurpose installation (overhead, direct buried. In ducts) in transport networks. The compact micro-module construction with fibre counts ranging from 12 to 144 fibres enables offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.The cables are ideally suited to installation within ducts using blown or pulling techniques and direct buried using plowing or trenching techniques, also for overhead scenarios such as lashed or short length unsupported spans
Features & benefits• Available in Fibre types SM G652D Nova, G657.A2.
Other fibre options in either single-mode or multi-mode optical fibres are available upon request.
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material.
• Double Jacket and FRP armoring is designed to beresistant to gunshots and rodents
• Diametrically opposed embedded strength membersprovides excellent crush protection performance.
• Fibre micro-modules are kink resistant and easilyremoved without the need for tools.
• Fast and easy midspan access.• Ultra-compactness, easier storage and faster
installation.
1. EMBEDDED STRENGTH MEMBER2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. WS YARNS5. SEMI DRY MICROMODULES WITH FIBRES6. INNER SHEATH7. WBT WITH FLAT FRP ARMORING8. RIPCORD(S)9. OUTER SHEATH
12c to 144F
• Longitudinal moisture protection is enabled by water blocking compounds in tube and core.• UV protected.• Tightly controlled physical parameters.• Combination of fibre types available on request
26
500150
500160
614.5176
815.3196
1216.0214
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
Product Performance
112.3133
10
Standard / Notes
IEC-60794-1-21-E1
IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11
IEC-60794-1-21-E10
IEC-60794-1-21-E7
IEC 60794-1-21- E3
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Specifications 12F/Module
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mm
Nominal Cable Weight (kg/km) ± 10%
TestMax Tensile strength Tm (daN)Maximum operating tensile strength Tm (daN)
Impact resistance (N.m)Cut-through resistance (N)
Static bend radius (mm)
Kink radius (mm)
Torsion
Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
12
±180°/m, L=200N
Installation: -5ºC to +45ºC
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
4555
12
400
200
500140
100 100 110 110 120 120
24
400
200
213.0148
500140
48
400
200
413.4154
72
400
200
500150
96
500
200
500160
144
500
200
physical characteristics
Mechanical and environmental characteristics
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
27
Yogalite™ Single Jacket for access networks adapted for Midspan access2d0144:dM012:X---Se
typical construction of cableproduct detailsYogaLite™ Single Jacket cable for duct installations with easy midspan access networks by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in ducts scenarios. The micro-module units consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress, and are constrained in a polyethylene sheath, which is provided with embedded strength members to protect from against buckling.
product applicationThe YogaLite™ Single Jacket Fibre Optic Cable is intended for external use only. The universal design is suited for use in most network arenas, including access. The compact micro-module construction with fibre counts ranging from 6 to 144 fibres enables offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.The cables are ideally suited to installation within ducts using blown or pulling techniques.
Features & benefits• Available in Fibre types SM G652D Nova, G657.A2.
Other fibre options in either single-mode or multi-mode optical fibres are available upon request.
• Designed for 1.5metres easy midspan access ofmicromodules
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material.
• Diametrically opposed embedded strength membersprovides excellent crush protection performance.
• Fibre micro-modules are kink resistant and easilyremoved without the need for tools.
• Ultra-compactness, easier storage and fasterinstallation.
• Longitudinal moisture protection is enabled by waterblocking compounds in tube and core.
• UV protected.• Tightly controlled physical parameters.• Combination of fibre types available on request
1. EMBEDDED STRENGTH MEMBERS2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. RIPCORD(S)5. WS YARNS6. SEMI DRY MICROMODULES WITH FIBRES7. OUTER SHEATH
6F to 144F
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
2
1
3
4
5
6
7
28
14070
14070
14070
610.069
89.867
810.677
1210.677
1212.098
Product Performance
Product Performance
17.443
17.241
150
150
Standard / Notes
IEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10IEC 60794-1-21- E3
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Standard / Notes
IEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10IEC 60794-1-21- E3
IEC-60794-1-22-F1
IEC-60794-1-22-F5B
Specifications 12F/Module
6F/Module
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
Fibre CountNumber of Fibres in Each MicromodulesNumber of Micromodule in each cableNominal Cable Diameter (mm) ± 0.5mmNominal Cable Weight (kg/km) ± 10%
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
12
12
Installation: -5ºC to +45ºC
Installation: -5ºC to +45ºC
1m water head, 3m samples, 24 hrs no water leakage
1m water head, 3m samples, 24 hrs no water leakage
Operation: -30ºC to +70ºC
Operation: -30ºC to +70ºC
Storage: -40ºC to +70ºC
Storage: -40ºC to +70ºC
2025
2025
3
3
12
6
100
100
14070
14070
24
12
100
100
28.955
28.551
14070
14070
48
24
100
100
49.261
48.856
72
48
100
100
14070
14070
96
72
100
100
14070
14070
144
100
physical characteristics
physical characteristics
Mechanical and environmental characteristics
Mechanical and environmental characteristics
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
** After the test, the change in attenuation shall be ≤ 0.05 dB/km. No damage or crack on cable & no fibre break.
29
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
30
2
1
3
4
5
6
7
Yogalite™ Single Jacket for indoor/Outdoor distribution2d0144:dM012:XF--Se
typical construction of cableproduct detailsYogaLite™ Single Jacket cable for duct installations with easy midspan access networks by Sterlite Tech™ is based on micro-module technology to create an optimized design preferably to be used in buildings, but are compatible with an installation in ductsover a short distance (about 300m) or on façades (building exteriors). The micro-module units consist of groups of fibres protected by an easily strippable and flexible thermoplastic material and filled with thixotropic compound. These microstructures are surrounded with water swelling elements to protect against moisture ingress, and are constrained in aflame retardant thermoplastic sheath, which is provided with embedded strength members to protect from against buckling.
product applicationThe YogaLite™ Single Jacket Fibre Optic Cable is intended for indoor/outdoor use. This design is suited for installation inbuildings, in ducts over a short distance (about 300m) or on façades.. The compact micro-module construction with fibre counts ranging from 6 to 144 fibres enables offers a versatile and compact construction with the benefits of quick fibre preparation ready for installation.
Features & benefits• Available in Fibre types SM G652D Nova, G657. A2.
Other fibre options in either single-mode or multi-mode optical fibres are available upon request.
• Reduced diameter micro- modules manufactured fromsoft and flexible elastomeric material.
• Diametrically opposed embedded strength membersprovides excellent crush protection performance.
• Fibre micro-modules are kink resistant and easilyremoved without the need for tools.
• Ultra-compactness, easier storage and fasterinstallation.
• Longitudinal moisture protection is enabled by waterblocking compounds in tube and core.
• Fire retardant.• Tightly controlled physical parameters.• Combination of fibre types available on request
1. EMBEDDED STRENGTH MEMBERS2. ARAMID YARNS3. CORE WRAPPING WITH WATER SWELLABLE TAPE4. RIPCORD(S)5. WS YARNS6. SEMI DRY MICROMODULES WITH FIBRES7. OUTER SHEATH
6F to 144F
performance StandardsCable Complies to the following main Standards IEC.60794 series, EN 60794, ANSI/ICEA S-87-640, Telcordia GR-20, ITU-T Recommendations
31
TestMax Tensile strength Tm (daN)Impact resistance (N.m)Cut-through resistance (N)Static bend radius (mm)Kink radius (mm)Torsion
Max Crushing resistance (daN/cm)
Temperature Cycling
Water Penetration
Mechanical and environmental characteristics*Standard / Notes
IEC-60794-1-21-E1IEC-60794-1-21-E4IEC-60794-1-21-E12IEC-60794-1-21-E11IEC-60794-1-21-E10IEC-60794-1-21-E7
IEC 60794-1-2 1- E3
IEC-60794-1-22-F1IEC-60794-1-22-F5B
** After the test, the change in attenuation shall be ≤ 0.05 dB/km.No damage or crack on cable & no fibre break.
6
1
5.9
45
9045
9045
9045
9045
9045
9045
120
12060
120
12060
120
14070
180
14070
12
2
7.5
55
24
4
7.9
65
36
6
8.4
72
24
8
2
7.9
64
36
3
8.3
70
48
4
8.8
77
72
6
9.5
86
96
8
9.5
105
144
12
12.2
145
Specifications 12F/Module
physical characteristicsFibre Count
Number of Fibres in Each Micromodules
Number of Micromodule in each cable
Nominal Cable Diameter (mm) ± 0.5mm
Nominal Cable Weight (kg/km) ± 10%
Installation: -5ºC to +45ºC Operation: -30ºC to +70ºC Storage: -40ºC to +70ºC
1m water head, 3m samples, 24 hrs no water leakage
70
2025
±180°/m, L=45N
±180°/m, L=45N
±180°/m, L=50N
±180°/m, L=55N
5300
Product Performance
6 12
cabled Optical Fibres characteristicsThe optical fibres are in accordance to the specifications ITU-T G.652D Nova and ITU-T G.657A2. Refer to specific data sheets for details.
transmission characteristics
Fibre Type
G652D Nova fibre
G657A2 fibre
1310nm
≤ 0,35 / 0,36
≤ 0,35 / 0,36
1550nm
≤ 0,22 / ≤ 0,23
≤ 0,22 / ≤ 0,23
1625nm
≤ 0,24 / ≤ 0,26
≤ 0,24 / ≤ 0,26
PMD, ps/√km
≤ 0 ,20
≤ 0 ,20
PMD LDVps/√km
≤ 0.10
≤ 0.15
Cut-off Wavelength (lcc), nm 1310nm
≤ 1260
≤ 1260
Attenuation coefficient, dB/km (Average/Maximum)
Fibre Standard colour code (as per eia/tia 598)
tube Standard color code (as per eia/tia 598)
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
White6
Blue1
Orange2
Green3
Brown4
Grey5
Red7
Black8
Yellow9
Violet10
Pink11
Aqua12
packing and lengthsPacking: Wooden drumsLengths (tolerance ±5%): 2km Note - Customised drum lengths available on request.
Sheath printing detailsSTERLITE < Fibre Type >< Meter Marking>
32
2
1
3
4
Yogalite™ Single Jacket for indoor riser installationsa20144:rM012:XF--Se
typical construction of cableproduct detailsYogaLite™ Single Jacket cable for indoor distribution application by Sterlite Tech™ is based on micro-module technology to create an optimized design suitable for use in vertical installation into the building scenarios. The micro-module units consist of groups of fibres protected by an easily strippable and flexible thermopl