Post on 04-Aug-2020
transcript
CISCO SYSTEMS PUBLICATION HISTORY170 WEST TASMAN DRSAN JOSE, CA, 95134 REV B.09 OCTOBER 15, 2020WWW.CISCO.COM
Spec Sheet
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node2
CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 10CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STEP 1 VERIFY SERVER CHASSIS SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13STEP 2 SELECT SERVER NODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14STEP 3 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15STEP 4 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17STEP 5 SELECT RAID CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDS) . . . . . . . . . . . . . 20STEP 7 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22STEP 8 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . 26STEP 9 ORDER M.2 SATA SSD (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29STEP 10 ORDER SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30STEP 11 ORDER MICRO-SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . 31STEP 12 ORDER OPTIONAL USB 3.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32STEP 13 ORDER SECURITY DEVICES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 34STEP 15 SELECT POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35STEP 16 SELECT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36STEP 17 SELECT TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM 37STEP 18 SELECT A KVM CABLE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38STEP 19 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 39STEP 20 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41STEP 21 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60DISCONTINUED EOL PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
OVERVIEW
OVERVIEWThe Cisco UCS C4200 Series Rack Server Chassis is a modular, dense rack server chassis that supports up to four UCS C125 M5 Rack Server Nodes, optimized for use in environments requiring dense compute form factor and high core densities such as scale-out/compute intensive, general service provider, and bare-metal applications.
The Cisco UCS C4200 chassis is a modular architecture consisting of the following modules:
■ Base Chassis: 24 SFF drive bays segmented into four groups of six direct attach drives (one group per node slot), four rear slots supporting C125 M5 server node, four redundant hot-pluggable fans, two 2400W AC high-line redundant power supplies, and a rail mounting kit.
■ Server Node: Each C125 M5 has two sockets supporting the AMD EPYC 7001 (Naples) and AMD EPYC 2 7002 (Rome) Processors up to 180W TDP, 16 DIMM slots for 2666 MHz DDR4 DIMMs (Naples) or 3200 MHz DDR4 DIMMs (Rome) and capacity points up to 64GB, up to 2 half-height/half-length PCI Express (PCIe) 3.0 slots, and optional M.2/SD module. The C125 supports either SAS RAID via a PCIe 12G SAS storage controller card, disk arrays via PCIe 12G SAS HBA, or SATA direct from the AMD EPYC CPU.
The node also includes a dedicated internal LAN mezzanine slot based on the OCP 2.0 standard supporting networking speeds up to 100Gbps. Additionally installation of a 4th generation Cisco PCIe Virtual Interface Card (VIC) can be added in the x16 PCIe 3.0 slot. An NVIDIA T4 GPU (graphics processing unit) is also supported.
The Cisco UCS C4200 can be used standalone, or as part of the Cisco Unified Computing System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture enabling end-to-end server visibility, management, and control in both bare metal and virtualized environments.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 4
OVERVIEW
Figure 1 Cisco UCS C4200 Storage Server
Rear ViewRear View
Front View
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node5
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
Figure 2 shows the Cisco UCS C4200.
Figure 2 Chassis Front View
1 Node Health LEDs 6 Node 1-controlled drive bays 1—6
2 Power Supply Status LED 7 Node 2-controlled drive bays 1—6
3 Locator beacon LED
Activating the locator beacon of any installed compute node activates this chassis locater beacon
8 Node 3-controlled drive bays 1—6
4 Temperature status LED 9 Node 4-controlled drive bays 1—6
5 Fan status LED 10 Pull-out asset tag
3064
51
1
23
45
6 7 8 9 10
Nod
e 1
01
Nod
e 1
02
Nod
e 1
03
Nod
e 1
04
Nod
e 1
05
Nod
e 1
06
Nod
e 2
01
Nod
e 2
02
Nod
e 2
03
Nod
e 2
04
Nod
e 2
05
Nod
e 2
06
Nod
e 3
01
Nod
e 3
02
Nod
e 3
03
Nod
e 3
04
Nod
e 3
05
Nod
e 3
06
Nod
e 4
01
Nod
e 4
02
Nod
e 4
03
Nod
e 4
04
Nod
e 4
05
Nod
e 4
06
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 6
DETAILED VIEWS
Chassis Rear View
Figure 4 shows the external features of the rear of the C4200 chassis with four C125 M5 server node (EPYC CPUs) installed.
Figure 3 Chassis Rear View
1 PCIe riser 1 handle (one each node) 7 Node 1 Gb Ethernet dedicated management port (one each node)
2 Node USB 3.0 port (one each node) 8 Node locator button/LED (one each node)
3 Node pull-out asset tag (one each node) 9 Node KVM local debug console port (one each node)
Used with KVM cable that provides one DB-15 VGA, one DB-9 serial, and two USB 2.0 connectors.
4 Node OCP adapter card Ethernet LAN ports (one each node, if this optional adapter card is installed)
Depending on which adapter card is installed, these ports can be either:
■ Dual 10 Gb Base-T (RJ-45 connectors)
■ Dual 10/25 Gb SFP28
10 PCIe slots (two horizontal slots each node)
■ Node PCIe riser 1/slot 1 (on left)
(half-height, half length, x8 slot)
■ Node PCIe riser 2/slot 2 (on right)
(half-height, half length, x16 slot)
5 Node securing thumbscrew and release lever (one each node)
11 Chassis power supplies (two, redundant 1+1)
6 Node Power button/Power status LED (one each node)
_
3064
52
23
45678
910 11
1
Node Bay 3
Node Bay 4
Node Bay 1
Node Bay 2
PSU 1
PSU 2
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node7
DETAILED VIEWS
Serviceable Components in the Chassis
The figure in this topic shows the locations of the serviceable components in the chassis.
For components inside a compute node, see the service note for your compute node: Cisco UCS C125 M5 Rack Server Node for Cisco UCS C4200 Rack Server Chassis Service Note.
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C125/install/C125.html
Figure 4
3064
53
Node Bay 3
Node Bay 4
Node Bay 1
Node Bay 2
PSU 1
PSU 2
1 2
65
7 8
3 4
Nod
e 1
01
Nod
e 1
02
Nod
e 1
03
Nod
e 1
04
Nod
e 1
05
Nod
e 1
06
Nod
e 2
01
Nod
e 2
02
Nod
e 2
03
Nod
e 2
04
Nod
e 2
05
Nod
e 2
06
Nod
e 3
01
Nod
e 3
02
Nod
e 3
03
Nod
e 3
04
Nod
e 3
05
Nod
e 3
06
Nod
e 4
01
Nod
e 4
02
Nod
e 4
03
Nod
e 4
04
Nod
e 4
05
Nod
e 4
06
Fan 1
Fan 2
Fan 3
Fan 4
Cisco UCS C4200 Chassis Serviceable Component Locations
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 8
DETAILED VIEWS
1 Front-loading drives
Node 1-controlled drive bays 1—6
5 Cooling fan modules (four)
2 Front-loading drives
Node 2-controlled drive bays 1—6
6 Supercap units (RAID backup)
Each supercap unit backs up one RAID controller in the corresponding node (numbered 1—4)
3 Front-loading drives
Node 3-controlled drive bays 1—6
7 Compute node (up to four)
4 Front-loading drives
Node 4-controlled drive bays 1—6
8 Power supplies (two, redundant 1+1)
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node9
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 12.
Table 1 Capabilities and Features
Capability/Feature Description
Chassis Two rack-unit (2RU) chassis
Central Processor The chassis supports two to four removable UCS C125 M5 nodes, each with two CPUs.
With four nodes, the system can total up to eight CPUs from the AMD EPYC 7001 Series (Naples) or AMD EPYC 2 7002 Series (Rome) up to 180W TDP.
GPU (graphics processing unit):
Up to two NVIDIA T4 GPUs are supported in a single C4200 chassis (one NVIDIA T4 in one C125 - two C125s maximum).
Memory The chassis supports two to four removable UCS C125 M5 nodes, each with two CPUs. Each CPU supports up to eight DIMMs.
With four nodes, the system can have a total up to 64 DIMMs.Multi-bit error protection
Multi-bit error protection is supported
Baseboard management
Each UCS C125 M5 node has a BMC, running Cisco Integrated Management Controller (Cisco IMC) firmware.
Depending on your settings, Cisco IMC can be accessed on each node through its 1-Gb dedicated management port or an adapter card.
Network and management I/O
The network and management I/O ports for this chassis are on the removable compute nodes. Each compute node has these connectors accessible from the rear of the chassis:
■ One 10/100/1000 Ethernet dedicated management port (RJ-45 connector)
■ One keyboard/video/mouse (KVM) console connector that is used with a KVM cable, which provides two USB 2.0, one DB-15 VGA, and one DB-9 serial connector.
■ One USB 3.0 port
■ Optional OCP adapter-card Ethernet LAN ports. Depending on which adapter is installed, these ports can be:
• Dual 10 Gb BASE-T (RJ-45 connectors)
• Dual 10/25 Gb SFP28Power Two power supplies, redundant as 1+1:
■ AC power supplies 2400 W AC each
Do not mix power supply types or wattages in the server.ACPI The advanced configuration and power interface (ACPI) 4.0 standard is supported.Cooling Four hot-swappable fan modules for front-to-rear cooling.PCIe I/O Each removable compute node has two PCIe risers for horizontal installation of
PCIe cards such as a RAID controller or Cisco Virtual Interface Card (VIC).InfiniBand The OCP and PCIe bus slots in the compute nodes support the InfiniBand
architecture. Check the Cisco HCL for more information.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 10
BASE SERVER STANDARD CAPABILITIES and FEATURES
Storage, front-panel
The chassis can hold up to 24 front-loading, 2.5-inch drives.
Each of the four removable compute nodes can control six of the front drives.Storage, internal Each of the four compute nodes have these internal storage options:
■ Mini-storage module socket, optionally with either:
• SD card carrier. Supports up to two SD cards
• M.2 SSD carrier. Supports two SATA M.2 SSDs
■ One micro-SD card socket.Storage management
Each of the four compute nodes support one RAID controller card. Each node can control six of the front-panel drives.
RAID supercap backup
Up to four supercap units are supported one for the RAID controller card in each node.
The supercap units have numbered bays and numbered cable connectors in the top of the chassis, corresponding to each numbered compute node.
Integrated video Integrated VGA video in each compute node. The DB-15 VGA connector is on the KVM cable that can be used with the KVM connector on each node.
Capability/Feature Description
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node11
CONFIGURING the SERVER
CONFIGURING the SERVERFollow these steps to configure the Cisco UCS C4200 Storage Server:
■ STEP 1 VERIFY SERVER CHASSIS SKU, page 13
■ STEP 2 SELECT SERVER NODE, page 14
■ STEP 3 SELECT CPU(s), page 15
■ STEP 4 SELECT MEMORY, page 17
■ STEP 5 SELECT RAID CONTROLLERS, page 18
■ STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDS), page 20
■ STEP 7 SELECT PCIe OPTION CARD(s), page 22
■ STEP 8 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES, page 26
■ STEP 10 ORDER SD CARD MODULE (OPTIONAL), page 30
■ STEP 11 ORDER MICRO-SD CARD MODULE (OPTIONAL), page 31
■ STEP 12 ORDER OPTIONAL USB 3.0 DRIVE, page 32
■ STEP 13 ORDER SECURITY DEVICES (OPTIONAL), page 33
■ STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL), page 34
■ STEP 15 SELECT POWER SUPPLY, page 35
■ STEP 16 SELECT POWER CORD(s), page 36
■ STEP 17 SELECT TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 37
■ STEP 18 SELECT A KVM CABLE (OPTIONAL), page 38
■ STEP 19 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 39
■ STEP 20 SELECT OPERATING SYSTEM MEDIA KIT, page 41
■ STEP 21 SELECT SERVICE and SUPPORT LEVEL, page 42
■ OPTIONAL STEP - ORDER RACK(s), page 48
■ OPTIONAL STEP - ORDER PDU, page 49
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 12
CONFIGURING the SERVER
STEP 1 VERIFY SERVER CHASSIS SKU
Select the base server product ID (PID) from Table 2.
Table 2 PID of the Cisco UCS C4200 Base Server Chassis
Product ID (PID) Description
UCSC-C4200-SFF Cisco UCS C4200 Rack Server Chassis, one rail kit, and bezel.
The Cisco UCS C4200 Multi-node Server:
■ Does not include internal storage drives, power supplies, or compute nodes (no CPU, memory, or Storage controller).
NOTE:
■ Use the steps on the following pages to configure the server with the components that you want to include.
■ The C4200 will support a minimum of two up to a maximum of four C125 M5 server nodes
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node13
CONFIGURING the SERVER
STEP 2 SELECT SERVER NODE
UCS C125 M5 Rack Server Node (with AMD EPYC 7001 (Naples) and AMD EPYC 2 (Rome) CPUs)
This server node is configurable. The base PID of the C125 M5 node is shown Table 3.
Table 3 C125 A1 Server Node Base PID
Product ID (PID) Description
UCSC-C125 UCS C125 M5 Rack Server Node based on AMD EPYC CPUs
UCSC-C125-U UCS C125 M5 Rack Server Node Standalone Configurable Spare
NOTE:
■ The C4200 will support a minimum of two up to a maximum of four C125 M5 server nodes
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 14
CONFIGURING the SERVER
STEP 3 SELECT CPU(s)
Use the following tables to choose options for the C125 M5 rack server node. The C125 M5 supports dual and single socket configurations up to 180W TDP.
Choose two CPUs from Table 4.
Table 4 Dual Socket CPUs
Product ID (PID)1
UCS-CPU-A7702 AMD 2.0GHz 7702 180W 64C/256MB Cache DDR4 3200MHz3
UCS-CPU-A7552 AMD 2.2GHz 7552 180W 48C/192MB Cache DDR4 3200MHz3
UCS-CPU-A7532 AMD 2.4GHz 7532 180W 32C/256MB Cache DDR4 3200MHz3
UCS-CPU-A7352 AMD 2.3GHz 7352 155W 24C/128MB Cache DDR4 3200MHz3
UCS-CPU-7601 2.2 GHz 7601 180W 32C/64MB Cache DDR4 2666MHz
UCS-CPU-7551 2.0 GHz 7551 180W 32C/64MB Cache DDR4 2666MHz
UCS-CPU-7451 2.3 GHz 7451 180W 24C/64MB Cache DDR4 2666MHz
UCS-CPU-7501 2.0 GHz 7501 155W/170W 32C/64MB Cache DDR4 2400/2666MHz
UCS-CPU-7401 2.0 GHz 7401 155W/170W 24C/64MB Cache DDR4 2400/2666MHz
UCS-CPU-7351 2.4 GHz 7351 155W/170W 16C/64MB Cache DDR4 2400/2666MHz
UCS-CPU-7301 2.2 GHz 7301 155W/170W 16C/64MB Cache DDR4 2400/2666MHz
UCS-CPU-7281 2.1 GHz 7281 155W/170W 16C 32MB Cache DDR4 2400/2666MHz
UCS-CPU-7261 2.5 GHz 7261 155W/170W 8C/64MB Cache DDR4 2400/2666MHz
UCS-CPU-7251 2.0 GHz 7251 120W 8C/32MB Cache DDR4 2400MHz
Notes:
1. Use the following table to choose a non-upgradeable single socket only configuration for the UCS C125 M5 server node. These PiDs cannot be used with a second processor, if your customer wants to upgrade to a second processor in the future it is recommended to use one the PIDs in Table 4
Description2
2. Selecting a single socket configuration will disable NVMe drive support. A second processor is required for NVMe
3. Orderability targeting August 2020
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node15
CONFIGURING the SERVER
■ Choose one CPUs from Table 5.
Table 5 Single Socket CPUs
Product ID (PID) Description
UCS-CPU-7551P 2.0 GHz 7551 180W 32C/64MB Cache DDR4 2666MHz
UCS-CPU-7401P 2.0 GHz 7401 155W/170W 24C/64MB Cache DDR4 2400/2666MHz
UCS-CPU-7351P 2.4 GHz 7351 155W/170W 16C/64MB Cache DDR4 2400/2666MHz
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 16
CONFIGURING the SERVER
STEP 4 SELECT MEMORY
■ Choose 4, 8, 16 DIMMs from Table 6.
Table 6 DIMMs
Product ID (PID) PID Description
UCS-MR-X16G1RW 16GB RDIMM SRx4 3200 (8Gb)1
Notes:
1. Orderability targeting August 2020
UCS-MR-X32G2RW 32GB RDIMM DRx4 3200 (8Gb)1
UCS-MR-X64G2RW 64GB RDIMM DRx4 3200 (16Gb)1
UCS-MR-X16G1RS-H 16GB DDR4-2666-MHz RDIMM/PC4-21300/single rank/x4/1.2v
UCS-MR-X32G2RS-H 32GB DDR4-2666-MHz RDIMM/PC4-21300/dual rank/x4/1.2v
UCS-MR-X64G4RS-H 64GB DDR4-2666-MHz RDIMM/PC4-21300/quad rank/x4/1.2v
UCS-MR-X64G2RT-HS 64GB DDR4-2933-MHz RDIMM/2Rx4/1.2v
UCS-MR-X64G2RW 64GB RDIMM DRx4 3200 (16Gb)
UCS-MR-X32G2RW 32GB RDIMM DRx4 3200 (8Gb)
UCS-MR-X16G1RW 16GB RDIMM SRx4 3200 (8Gb)
NOTE:
■ The AMD EPYC 7001/7002 CPUs features a high performance 8-channel memory controller. It is recommended to always populate every DIMM slot for best system performance, however if fewer DIMMs are desired a minimum of 4 DIMMs per CPU is generally recommended.
■ Unbalanced memory configurations should be avoided.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node17
CONFIGURING the SERVER
STEP 5 SELECT RAID CONTROLLERS
RAID Controller Options
Embedded SATA AHCI Controller
The default configuration is embedded SATA AHCI Controller from the EPYC CPU (CPU0) which features no RAID support and supports only SATA HDDs and enterprise value SSDs. A maximum of 6 SATA drives are supported with embedded SATA Controller. When the Embedded SATA controller is used, the PCIe riser 1 slot can be used with other PCIe add-on-cards.
■ Choose a storage controller from Table 7
Table 7 RAID Controller
Product ID (PID) PID Description
UCSC-RAID-C125KIT UCS C125 9460-8i RAID kit
UCSC-HBA-C125KIT UCS C125 9400-8i HBA kit
CAUTION: Always shut down the node before removing it from the chassis, as described in the user manual. Failure to shut down the node before removal results in the corresponding RAID supercap cache being discarded and other data might be lost.
Table 8 Hardware Controller Options
Product ID (PID) PID Description
Controllers for Internal Drives
Note that if the following Cisco 12G SAS RAID PCIe controller is selected, it is factory-installed in the Riser 1 PCIe slot.
UCSC-RAID-C125KIT UCS C125 9460-8i RAID kit
UCSC-HBA-C125KIT UCS C125 9400-8i HBA kit
RAID Configuration Options (not available for embedded SATA controller)
R2XX-SRAID0 Enable Single Disk Raid 0 Setting
R2XX-RAID0 Factory preconfigured RAID striping option Enable RAID 0 Setting.
Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting.
Requires exactly two drives with the same size, speed, capacity.
R2XX-RAID5 Factory preconfigured RAID option Enable RAID 5 Setting.
Requires a minimum of three drives of the same size, speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option Enable RAID 6 Setting.
Requires a minimum of four drives of the same size, speed, capacity.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 18
CONFIGURING the SERVER
R2XX-RAID10 Factory preconfigured RAID option Enable RAID 10 Setting.
Requires a minimum of four drives of the same size, speed, capacity.
Table 8 Hardware Controller Options (continued)
Product ID (PID) PID Description
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node19
CONFIGURING the SERVER
STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDS)
The standard disk drive features are:
■ 2.5-inch small form factor
■ Hot-pluggable
■ Drives come mounted in sleds
Select front-facing Drives
The available drives are listed in Table 9.
Table 9 Available Additional HDDs and SSDs
Product ID (PID) PID DescriptionDrive Type
Capacity
HDDs
UCS-HD600G10KJ4 Cisco UCS C4200 600GB 12Gbps 10K HDD SAS-3 600GB
UCS-HD12TB10KJ4 Cisco UCS C4200 1.2TB 12Gbps 10K HDD SAS-3 1.2TB
UCS-HD18TB10KJ4 Cisco UCS C4200 1.8TB 12Gbps 10K HDD (4K) SAS-3 1.8TB
UCS-HD24TB10KJ4 Cisco UCS C4200 2.4TB 12Gbps 10K HDD (4K) SAS-3 2.4TB
SSDs
Self-Encrypted Drives (SED)1
UCS-SD400GBHNK9 Cisco UCS C4200 400GB 12Gbps SSD SED SAS 400GB
UCS-SD800GBHNK9 Cisco UCS C4200 800GB 12Gbps SSD SED SAS 800GB
UCS-SD16TBHNK9 Cisco UCS C4200 1.6TB 12Gbps SSD SED SAS 1.6TB
Enterprise Performance 3X Read
UCS-SD400G123X-EP Cisco UCS C4200 400GB 12Gbps SSD SAS-3 400GB
UCS-SD800G123X-EP Cisco UCS C4200 800GB 12Gbps SSD SAS-3 800GB
UCS-SD16T123X-EP Cisco UCS C4200 1.6TB 12Gbps SSD SAS-3 1.6TB
UCS-SD32T123X-EP Cisco UCS C4200 3.2TB 12Gbps SSD SAS-3 3.2TB
Enterprise Value 1X Read
UCS-SD960G61X-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960GB
UCS-SD19T61X-EV 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9TB
UCS-SD38T61X-EV 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8TB
UCS-SD120GM1X-EV Cisco UCS C4200 120GB 6Gbps SSD SATA 120GB
UCS-SD240GM1X-EV Cisco UCS C4200 240GB 6Gbps SSD SATA 240GB
UCS-SD480GM1X-EV Cisco UCS C4200 480GB 6Gbps SSD SATA 480GB
UCS-SD16TM1X-EV Cisco UCS C4200 1.6TB 6Gbps SSD SATA 1.6TB
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 20
CONFIGURING the SERVER
UCS-SD76TM1X-EV Cisco UCS C4200 7.6TB 6Gbps SSD SATA 7.6TB
NVMe2
UCSC-NVMEHW-H800 Cisco UCS C4200 U.2 800GB HGST SN200 NVMe 800GB
UCSC-NVMEHW-H1600 Cisco UCS C4200 U.2 1.6TB HGST SN200 NVMe 1.6TB
UCSC-NVMEHW-H3200 Cisco UCS C4200 U.2 3.2TB HGST SN200 NVMe 3.2TB
UCSC-NVMEHW-H6400 Cisco UCS C4200 U.2 6.4TB HGST SN200 NVMe 6.4TB
UCSC-NVME2H-I1000 Cisco 2.5" U.2 1,0 TB Intel P4510 NVMe High Perf. Value Endu NVMe 1.0 TB
UCSC-NVME2H-I4000 Cisco 2.5" U.2 4.0TB Intel P4510 NVMe High Perf. Value Endu NVMe 4.0 TB
UCSC-NVME2H-I1600 Cisco 2.5" U.2 1.6TB Intel P4610 NVMe High Perf. High Endu NVMe 1,6 TB
UCSC-NVME2H-I3200 Cisco 2.5" U.2 3.2TB Intel P4610 NVMe High Perf. High Endu NVMe 3.2 TB
NOTE: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state drives (SSDs) are subject to physical write limits and have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state drives (SSDs) that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by Cisco.
NOTE:
■ To Add Individual Drives, use the HDD or SSD Tab in CCW
Notes:
1. For all self-encrypting drives (SED), standalone Management (CIMC) and UCSM is supported for configuring and managing local keys. SED drives can be managed with local and remote key management (third-party key management).
2. Two CPUs must be installed in order to include any number of SFF NVMe SSDs. If you choose one or two SFF NVMe drives, drive slots 1 and 2 are reserved for these drives (see Figure 9 on page 53 for drive slot numbering)
Table 9 Available Additional HDDs and SSDs
Product ID (PID) PID DescriptionDrive Type
Capacity
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node21
CONFIGURING the SERVER
STEP 7 SELECT PCIe OPTION CARD(s)
The standard PCIe card offerings are:
■ OCP LAN Module (OCP)
■ Fiber channel
■ PCIe Virtual Interface Cards (VICs)
■ GPU
Select PCIe Option Cards
The available PCIe option cards are listed in Table 10.
Table 10 Available PCIe Option Cards 1
Product ID (PID) PID DescriptionForm Factor
Electrical Slot
OCP mezzanine
10 Gb
UCSC-OCP-QD10GC Dual Port QL41132HORJ-CI-BK 10Gbase-T OCP 1.0 OCP N/A
25 Gb
UCSC-OCP-QD25GF Qlogic QL41232HOCU Dual Port 25G SFP28 OCP 1.0 OCP N/A
UCSC-O-ID25GF Intel XXV710DA2OCP1 2x25/10GbE OCP 2.0 OCP N/A
100 Gb
UCSC-O-M5S100GF MELLANOX MCX545B-ECAN 1x100Gb QSFP28 IB/ENET OCP2.0 NIC
OCP N/A
NICs (Networking interface Card)
10 Gb
UCSC-PCIE-IQ10GF Intel X710 Quad Port 10G SFP+ NIC HHHL x 8
UCSC-PCIE-QD10GC QLogic dual-port 10GBase-T QL41162HLRJ-11-SP HHHL x 8
25 Gb
UCSC-PCIE-QD25GF QLogic dual-port 25G SFP QL41212HLCU-CI-BK HHHL x 8
UCSC-PCIE-ID25GF Intel XXV710-DA2 2x25GbE SFP+ PCIe NIC HHHL x 8
UCSC-P-M5D25GF Mellanox MCX512A-ACAT dual port 10/25G SFP28 NIC HHHL x 8
Fiber channel/HBA
UCSC-PCIE-QD16GF Qlogic QLE2692 2x16Gb Gen 6 FC HBA HHHL x 8
PCIe Virtual Interface Cards (VICs)
25Gb
UCSC-PCIE-C25Q-04 Cisco UCS VIC 1455 Quad Port 10/25G SFP28 CNA PCIE HHHL
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 22
CONFIGURING the SERVER
NOTE:
■ Maximum of 1 NVIDIA T4 GPU per C125. Maximum of 2 C125 each with T4 in one C4200 chassis.
■ 2 additional C125s (without T4) are allowed in the same C4200 chassis for a total 4xC125: 2xC125xT4 and 2xC125
■ Cisco VIC 1495 supports 40/100G.
■ Other optics available that support 40G.
■ Note that QSFP-40/100-SRBD supported at 100G only.
■ For list of supported cables and optics with VIC 1495 refer to the VIC 1400 series data sheet.
■ Mixing 1300 and 1400 series VIC and MLOMs configurations is not supported.
UCS VIC Transceiver and Cable Support Matrix
The supported transceivers are listed in Table 11
100Gb
UCSC-PCIE-C100-04 Cisco VIC 1495 Dual Port 100G QSFP28 CNA PCIe HHHL
GPU
UCSC-GPU-T4-16 NVIDIA T4 PCIe 75W 16GB HHHL
Notes:
1. Refer to the Cisco HCL (Hardware Compatibility List) for additional card support including InfiniBand
Table 11 Cisco UCS VIC Transceiver and Cable Support Matrix
Product ID (PID) Description
SFP+ 10-Gbps Transceivers
SFP-10G-SR 10GBASE-SR, 850 nm, MMF, 300m
SFP-10G-SR-S 10GBASE-SR, 850 nm, MMF, 300m, S-Class
SFP-10G-LR 10GBASE-LR, 1310 nm, SMF, 10 km
SFP-10G-LR-S 10GBASE-LR, 1310 nm, SMF, 10 km, S-Class
QSFP+ 25-Gbps Transceivers
SFP-25G-SR-S 25GBASE-SR SFP+, 850nm, MMF, 300m, S-Class
SFP+ 10-Gbps Cables with Integrated Transceivers
SFP-H10GB-CU1M 10GBASE-CU SFP+ cable 1M
Table 10 Available PCIe Option Cards (continued)1
Product ID (PID) PID DescriptionForm Factor
Electrical Slot
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node23
CONFIGURING the SERVER
SFP-H10GB-CU2M 10GBASE-CU SFP+ cable 2M
SFP-H10GB-CU3M 10GBASE-CU SFP+ cable 3M
SFP-H10GB-CU5M 10GBASE-CU SFP+ cable 5M
SFP-H10GB-ACU7M 10GBASE-CU SFP+ cable 7M
SFP-H10GB-ACU10M 10GBASE-CU SFP+ cable 10M
SFP-10G-AOC1M 10GBASE Active Optical SFP+ cable, 1M
SFP-10G-AOC2M 10GBASE Active Optical SFP+ cable, 2M
SFP-10G-AOC3M 10GBASE Active Optical SFP+ cable, 3M
SFP-10G-AOC5M 10GBASE Active Optical SFP+ cable, 5M
SFP-10G-AOC7M 10GBASE Active Optical SFP+ cable, 7M
SFP-10G-AOC10M 10GBASE Active Optical SFP+ cable, 10M
SFP28 25-Gbps Cables with Integrated Transceivers
SFP-H25G-CU1M 25GBASE-CU SFP28 cable 1M
SFP-H25G-CU2M 25GBASE-CU SFP28 cable 2M
SFP-H25G-CU3M 25GBASE-CU SFP28 cable 3M
SFP-H25G-CU5M 25GBASE-CU SFP28 cable 5M
QSFP 40-Gbps Cables
QSFP-4x10G-AC7M 40GBASE-CR4 QSFP+ to 4x10GBASE-CU SFP+ direct-attach creakout cable,7M
QSFP-4x10G-AC10M 40GBASE-CR4 QSFP+ to 4x10GBASE-CU SFP+ direct-attach breakout cable, 10M
QSFP-4SFP10G-CU1M 40GBASE-CR4 QSFP+ to 4x10GBASE-CU SFP+ passive direct-attach cable, 1M
QSFP-4SFP10G-CU3M 40GBASE-CR4 QSFP+ to 4x10GBASE-CU SFP+ passive direct-attach cable, 3M
QSFP-4SFP10G-CU5M 40GBASE-CR4 QSFP+ to 4x10GBASE-CU SFP+ passive direct-attach cable, 5M
QSFP-4X10G-AOC1M 40GBASE-active optical QSFP to 4xSFP+ active optical breakout cable, 1M
QSFP-4X10G-AOC2M 40GBASE-active optical QSFP to 4xSFP+ active optical breakout cable, 2M
QSFP-4X10G-AOC3M 40GBASE-active optical QSFP to 4xSFP+ active optical breakout cable, 3M
QSFP-4X10G-AOC5M 40GBASE-active optical QSFP to 4xSFP+ active optical breakout cable, 5M
QSFP-4X10G-AOC7M 40GBASE-active optical QSFP to 4xSFP+ active optical breakout cable, 7M
QSFP-4X10G-AOC10M 40GBASE-active optical QSFP to 4xSFP+ active optical breakout cable, 10M
QSFP 100-Gbps Cables
QSFP-4SFP25G-CU1M 100GBASE QSFP to 4xSFP25G passive copper splitter cable, 1M
Table 11 Cisco UCS VIC Transceiver and Cable Support Matrix
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 24
CONFIGURING the SERVER
QSFP-4SFP25G-CU2M 100GBASE QSFP to 4xSFP25G passive copper splitter cable, 2M
QSFP-4SFP25G-CU3M 100GBASE QSFP to 4xSFP25G passive copper splitter cable, 3M
NOTE: Supported transceivers and cables for Cisco VIC cards. For the supported list of transceivers and cables for QLogic OCP cards please referrer to the QLogic 41000 Series interoperability matrix on the Marvell | Cavium website for more information
Table 11 Cisco UCS VIC Transceiver and Cable Support Matrix
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node25
CONFIGURING the SERVER
STEP 8 ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
■ For list of supported optics and cables for VIC 1455, VIC 1457, VIC 1495 and VIC 1497 refer to VIC 1400 series data sheet at the following links:
— https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/unified-computing-system-adapters/datasheet-c78-741130.html
— https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/unified-computing-system-adapters/datasheet-c78-734727.html
Select
■ NIC Interoperability with Cisco Cables/Optics. (Table 12.0 to 12.0.C)
Table 12.0 10G NIC Interoperability with Cables/Optics
Cisco Product ID (PID) UCSC-PCIE-IQ10GC
Cisco Direct Attach Cables (DAC)
UTP/RJ45 ✓
Table 12.0.a 25G NIC Interoperability with Cables/Optics
Cisco Product ID (PID) UCSC-O-ID25GF UCSC-OCP-QD25GF UCSC-PCIE-ID25GF
Cisco Direct Attach Cables (DAC)
SFP-H10GB-CU1M ✓ ✓
SFP-H10GB-CU3M ✓ ✓
SFP-H10GB-CU5M ✓ ✓
SFP-H10GB-ACU7M ✓
SFP-H10GB-ACU10M ✓
SFP-10G-AOC1M ✓
SFP-10G-AOC2M ✓
SFP-10G-AOC3M ✓
SFP-10G-AOC5M ✓
SFP-10G-AOC7M ✓
SFP-25G-AOC10M ✓ ✓
QSFP-4SFP25G-CU3M ✓
SFP-H25G-CU1M ✓ ✓
SFP-H25G-CU2M ✓ ✓
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 26
CONFIGURING the SERVER
SFP-H25G-CU3M ✓ ✓
SFP-H25G-CU5M ✓ ✓
SFP-25G-AOC1M ✓
SFP-25G-AOC2M ✓
SFP-25G-AOC3M ✓
SFP-25G-AOC4M ✓
SFP-25G-AOC5M ✓
SFP-25G-AOC7M ✓
QSFP-100G-AOC10M ✓
QSFP-100G-CU5M ✓
Cisco Optical Transceivers
SFP-10G-SR ✓ ✓
SFP-10G-SR-S ✓
SFP-10G-LR ✓ ✓
SFP-10G-LR-S ✓
SFP-25G-SR-S ✓ ✓
SFP-10/25G-LR-S ✓ ✓
QSFP-100G-SR4-S ✓
Table 12.0.c 100G NIC Interoperability with Cables/Optics
Cisco Product ID (PID) UCSC-P-M5S100GF
Cisco Direct Attach Cables (DAC)
QSFP-100G-AOC5M ✓
QSFP-100G-AOC7M ✓
QSFP-100G-CU3M ✓
QSFP-100G-CU5M ✓
Cisco Optical Transceivers
Table 12.0.a 25G NIC Interoperability with Cables/Optics
Cisco Product ID (PID) UCSC-O-ID25GF UCSC-OCP-QD25GF UCSC-PCIE-ID25GF
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node27
CONFIGURING the SERVER
a. *: Compiled from testing conducted by Cisco TMG and Vendors.b. Refer to the these links for additional Connectivity Options.
Intel: Marvell/Qlogic: Mellanox:
Product Guide 41000 series Interoperability Matrix Firmware Release Notes
Speed White Paper 45000 series Interoperability Matrix
QSFP-100G-LR4-S ✓
QSFP-100G-SR4-S ✓
QSFP-40/100-SRBD ✓
Table 12.0.c 100G NIC Interoperability with Cables/Optics
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 28
CONFIGURING the SERVER
STEP 9 ORDER M.2 SATA SSD (OPTIONAL)
Order one or two matching capacity M.2 SATA SSDs as desired.
Table 13 M.2 SATA SSDs
Product ID (PID) PID Description
UCS-M2-240GB 240 GB M.2 SATA SSD
UCS-M2-960GB 960 GB M.2 SATA SSD
UCS-M2-HWRAID Cisco Boot optimized M.2 Raid controller
Caveats
— Install either one or two M.2 SATA SSDs.
— You cannot mix M.2 SATA SSDs with SD cards (see ORDER SD CARD MODULE (OPTIONAL))
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node29
CONFIGURING the SERVER
STEP 10 ORDER SD CARD MODULE (OPTIONAL)
Order SD cards. There are two locations, SD1 and SD2.
Table 14 128 GB Secure Digital (SD) Card
Product ID (PID) PID Description
UCS-SD-128G 128 GB SD Card for UCS Servers
UCS-SD-64G-S 64 GB SD Card for UCS Servers
UCS-SD-32G-S 32 GB SD Card for UCS Servers
Caveats
— Install either one or two SD cards
— Do not mix SD card sizes
— You cannot mix SD cards with an internal M.2 SATA SSDs (see ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES).
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 30
CONFIGURING the SERVER
STEP 11 ORDER MICRO-SD CARD MODULE (OPTIONAL)
Order one or two matching capacity M.2 SATA SSDs as desired.
Table 15 32 GB Secure Digital (SD) Card
Product ID (PID) PID Description
UCS-MSD-32G 32GB Micro-SD Card for UCS servers
Caveats
— Install either one or two M.2 SATA SSDs.
— You cannot mix M.2 SATA SSDs with SD (see ORDER SD CARD MODULE (OPTIONAL)).
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node31
CONFIGURING the SERVER
STEP 12 ORDER OPTIONAL USB 3.0 DRIVE
You can order one optional USB 3.0 drive.
The USB drive ordering information is listed in
Table 16 USB 3.0 Drive
Product ID (PID) PID Description
UCS-USBFLSHB-16GB= UCS Servers 16 GB Flash USB Drive
Table 16
See Figure 6 on page 50 for the location of the USB connector
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 32
CONFIGURING the SERVER
STEP 13 ORDER SECURITY DEVICES (OPTIONAL)
A Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.
A chassis intrusion switch gives a notification of any unauthorized mechanical access into the server. The security device ordering information is listed in Table 18.
Table 17 TPM
Product ID (PID) PID Description
UCSX-TPM2-002-C Trusted Platform Module 2.0 for UCS servers
Choose an optional Trusted Platform Module (TPM) from Table 17.
NOTE:
■ The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined by the Trusted Computing Group (TCG). It is also SPI-based.
■ TPM installation is supported after-factory. However, a TPM installs with a one-way screw and cannot be replaced, upgraded, or moved to another server. If a server with a TPM is returned, the replacement server must be ordered with a new TPM.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node33
CONFIGURING the SERVER
STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL)
An optional locking bezel can be mounted to the front of the chassis to prevent unauthorized access to the drives.
Table 18 C4200 Locking Security Bezel
Product ID (PID) PID Description
UCSC-BZL-C240M5 Locking Security Bezel for 2U C-series rack servers
Select the locking bezel Table 18
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 34
CONFIGURING the SERVER
STEP 15 SELECT POWER SUPPLY
The Cisco UCS C4200 accommodates two power supplies. Two power supplies are mandatory.
Use Table 19 to order the power supplies.
Table 19 Power Supply
Product ID (PID) PID Description
UCSC-PSU3-2400W UCS C4200 2400W Power Supply Unit
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node35
CONFIGURING the SERVER
STEP 16 SELECT POWER CORD(s)
Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.
Using Table 20, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
Table 20 Available Power Cords
Product ID (PID) PID Description Images
R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option)
Not applicable
CAB-AC-2500W-EU Power Cord, 250Vac 16A, Europe Images not available
CAB-AC-2500W-INT Power Cord, 250Vac 16A, INTL Images not available
CAB-C19-CBN Cabinet Jumper Power Cord, 250 VAC 16A, C20-C19 Connectors
Images not available
CAB-AC-C6K-TWLK Power Cord, 250Vac 16A, twist lock NEMA L6-20 plug, US
Images not available
CAB-AC-2500W-US1 Power Cord, 250Vac 16A, straight blade NEMA 6-20 plug, US
Images not available
CAB-AC-16A-AUS Power Cord, 250VAC, 16A, Australia C19 Images not available
CAB-AC16A-CH 16A AC Power Cord For China Images not available
CAB-AC-2500W-ISRL Power Cord,250VAC,16A,Israel Images not available
CAB-S132-C19-ISRL S132 to IEC-C19 14ft Israeli Images not available
CAB-ACS-16 AC Power Cord (Swiss) 16A Images not available
CAB-IR2073-C19-AR IRSM 2073 to IEC-C19 14ft Argen Images not available
CAB-BS1363-C19-UK BS-1363 to IEC-C19 14ft UK Images not available
CAB-SABS-C19-IND SABS 164-1 to IEC-C19 India Images not available
CAB-C2316-C19-IT CEI 23-16 to IEC-C19 14ft Italy Images not available
CAB-9K16A-BRZ Power Cord 250VAC 16A, Brazil, Src Plug EL224-C19 Images not available
CAB-C19-C20-3M-JP Power Cord C19-C20, 3M/10ft Japan PSE mark Images not available
CAB-L520P-C19-US NEMA L5-20 to IEC-C19 6ft US Images not available
CAB-US620P-C19-US NEMA 6-20 to IEC-C19 13ft US Images not available
CAB-9K16A-KOR Power Cord 250VAC 16A, Korea, Src Plug Images not available
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 36
CONFIGURING the SERVER
STEP 17 SELECT TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM
The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 22 to order a cable management arm.
Select a Tool-less Rail Kit
Select a tool-less rail kit from Table 21.
Table 21 Tool-less Rail Kit Options
Product ID (PID) PID Description
UCSC-RAILF-M4 Friction Rail Kit for C220 M4 and C220 M5 Servers
UCSC-RAILB-M4 Ball Bearing Rail Kit for C220 and C240 M4/M5 Rack Servers
Table 22 Cable Management Arm
Product ID (PID) PID Description
UCSC-CMAF-C4200 Reversible CMA for C4200 ball bearing rail kit
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node37
CONFIGURING the SERVER
STEP 18 SELECT A KVM CABLE (OPTIONAL)
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB 2.0 ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server.
The KVM cable ordering information is listed in Table 23.
Table 23 KVM Cable
Product ID (PID) PID Description
N20-BKVM= KVM cable for server console port
Figure 5 KVM Cable
1 Connector (to server front panel) 3 VGA connector (for a monitor)
2 DB-9 serial connector 4 Two-port USB 2.0 connector (for a mouse and keyboard)
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 38
CONFIGURING the SERVER
STEP 19 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE
Several operating systems and value-added software programs are available. Select as desired from Table 24.
Table 24 Operating System
Product ID (PID) PID Description
Microsoft Windows Server
MSWS-19-DC16C Windows Server 2019 Data Center (16 Cores/Unlimited VMs)
MSWS-19-DC16C-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC
MSWS-19-ST16C Windows Server 2019 Standard (16 Cores/2 VMs)
MSWS-19-ST16C-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
Red Hat
RHEL-2S2V-1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
RHEL-2S2V-3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req
RHEL-VDC-2SUV-1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req
RHEL-VDC-2SUV-3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req
RHEL-VDC-2SUV-5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req
Red Hat Ent Linux/ High Avail/ Res Strg/ Scal
RHEL-2S2V-1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1-Yr SnS
RHEL-2S2V-3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3-Yr SnS
RHEL-2S-HA-1S RHEL High Availability (1-2 CPU); Premium 1-yr SnS
RHEL-2S-HA-3S RHEL High Availability (1-2 CPU); Premium 3-yr SnS
RHEL-2S-RS-1S RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS
RHEL-2S-RS-3S RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS
RHEL-2S-SFS-1S RHEL Scalable File System (1-2 CPU); Premium 1-yr SnS
RHEL-2S-SFS-3S RHEL Scalable File System (1-2 CPU); Premium 3-yr SnS
RHEL-VDC-2SUV-1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd
RHEL-VDC-2SUV-3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd
VMware
VMW-VSP-STD-1A VMware vSphere 6 Standard (1 CPU), 1-yr, Support Required
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node39
CONFIGURING the SERVER
VMW-VSP-STD-3A VMware vSphere 6 Standard (1 CPU), 3-yr, Support Required
VMW-VSP-STD-5A VMware vSphere 6 Standard (1 CPU), 5-yr, Support Required
VMW-VSP-EPL-3A VMware vSphere 6 Ent Plus (1 CPU), 3-yr, Support Required
VMW-VSP-EPL-1A VMware vSphere 6 Ent Plus (1 CPU), 1-yr, Support Required
VMW-VSP-EPL-5A VMware vSphere 6 Ent Plus (1 CPU), 5-yr, Support Required
SUSE
SLES-2S2V-1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
SLES-2SUV-1A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 1-Yr Support Req
SLES-2S2V-3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2SUV-3A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 3-Yr Support Req
SLES-2S2V-5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2SUV-5A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 5-Yr Support Req
SLES-2S2V-1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2SUV-1S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 1-Yr SnS
SLES-2S2V-3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS
SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 3-Yr SnS
SLES-2S2V-5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS
SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 5-Yr SnS
SLES-2S-HA-1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
SLES-2S-GC-3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS
SLES-2S-LP-1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required
SLES-2S-LP-3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required
SLES-2S-LP-1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req
SLES-2S-LP-3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req
Table 24 (continued)Operating System
Product ID (PID) PID Description
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 40
CONFIGURING the SERVER
STEP 20 SELECT OPERATING SYSTEM MEDIA KIT
Select the optional operating system media listed in Table 25.
Table 25 OS Media
Product ID (PID) PID Description
MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node41
CONFIGURING the SERVER
STEP 21 SELECT SERVICE and SUPPORT LEVEL
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:
■ Three-year parts coverage.
■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
■ 90-day software warranty on media.
■ Ongoing downloads of BIOS, drivers, and firmware updates.
■ UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.
Smart Net Total Care (SNTC) for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco Smart Net Total Care for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world
For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco Smart Net Total Care for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. For more information please refer to the following url: http://www.cisco.com/c/en/us/services/technical/smart-net-total-care.html?stickynav=1
You can choose a desired service listed in Table 26.
Table 26 Cisco SNTC for UCS Service (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-PREM-C4200SFF C2P Yes SNTC 24X7X2OS
CON-UCSD8-C4200SFF UCSD8 Yes UC SUPP DR 24X7X2OS*
CON-OSP-C4200SFF C4P Yes SNTC 24X7X4OS
CON-UCSD7-C4200SFF UCSD7 Yes UCS DR 24X7X4OS*
CON-C4PL-C4200SFF C4PL Yes LL 24X7X4OS**
CON-USD7L-C4200SFF USD7L Yes LLUCS HW DR 24X7X4OS***
CON-OSE-C4200SFF C4S Yes SNTC 8X5X4OS
CON-UCSD6-C4200SFF UCSD6 Yes UC SUPP DR 8X5X4OS*
CON-SNCO-C4200SFF SNCO Yes SNTC 8x7xNCDOS****
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 42
CONFIGURING the SERVER
Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service
An enhanced offer over traditional Smart Net Total Care which provides onsite-troubleshooting expertise to aid in the diagnostics and isolation of hardware issue within our customers’ Cisco Unified Computing System (UCS) environment. It is delivered by a Cisco Certified field engineer (FE) in collaboration with remote TAC engineer and Virtual Internet working Support Engineer (VISE). You can choose a desired service listed in
Table 27 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-OSPT-C4200SFF OSPT Yes 24X7X4OS Trblshtg
CON-OSPTD-C4200SFF OSPTD Yes 24X7X4OS TrblshtgDR*
*Includes Drive Retention (see below for full description)
Table 27
CON-OS-C4200SFF CS Yes SNTC 8X5XNBDOS
CON-UCSD5-C4200SFF UCSD5 Yes UCS DR 8X5XNBDOS*
CON-S2P-C4200SFF S2P No SNTC 24X7X2
CON-SNTP-C4200SFF SNTP No SNTC 24X7X4
CON-SNTPL-C4200SFF SNTPL No LL 24X7X4**
CON-SNTE-C4200SFF SNTE No SNTC 8X5X4
CON-SNC-C4200SFF SNC No SNTC 8x7xNCD****
CON-SNT-C4200SFF SNT No SNTC 8X5XNBD
CON-SW-C4200SFF SW No SNTC NO RMA
*Includes Drive Retention (see below for full description)
**Includes Local Language Support (see below for full description) – Only available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan
****Available in China Only
Table 26 Cisco SNTC for UCS Service (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node43
CONFIGURING the SERVER
Solution Support for UCS
Solution Support includes both Cisco product support and solution-level support, resolving complex issues in multivendor environments, on average, 43% more quickly than product support alone. Solution Support is a critical element in data center administration, to help rapidly resolve any issue encountered, while maintaining performance, reliability, and return on investment.
This service centralizes support across your multivendor Cisco environment for both our products and solution partner products you’ve deployed in your ecosystem. Whether there is an issue with a Cisco or solution partner product, just call us. Our experts are the primary point of contact and own the case from first call to resolution. For more information please refer to the following url:http://www.cisco.com/c/en/us/services/technical/solution-support.html?stickynav=1You can choose a desired service listed in
Table 28 Solution Support for UCS Service (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-SSC2P-C4200SFF SSC2P Yes SOLN SUPP 24X7X2OS
CON-SSC4P-C4200SFF SSC4P Yes SOLN SUPP 24X7X4OS
CON-SSC4S-C4200SFF SSC4S Yes SOLN SUPP 8X5X4OS
CON-SSCS-C4200SFF SSCS Yes SOLN SUPP 8X5XNBDOS
CON-SSDR7-C4200SFF SSDR7 Yes SSPT DR 24X7X4OS*
CON-SSDR5-C4200SFF SSDR5 Yes SSPT DR 8X5XNBDOS*
CON-SSS2P-C4200SFF SSS2P No SOLN SUPP 24X7X2
CON-SSSNP-C4200SFF SSSNP No SOLN SUPP 24X7X4
CON-SSSNE-C4200SFF SSSNE No SOLN SUPP 8X5X4
CON-SSSNC-C4200SFF SSSNC No SOLN SUPP NCD**
CON-SSSNT-C4200SFF SSSNT No SOLN SUPP 8X5XNBD
Includes Drive Retention (see below for description)
**Available in China only
Table 28
Smart Net Total Care for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Smart Net Total Care for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. Smart Net Total Care for UCS Hardware Only Service provides remote access any time to Cisco
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 44
CONFIGURING the SERVER
support professionals who can determine if a return materials authorization (RMA) is required. You can choose a desired service listed in
Table 29 SNTC for UCS Hardware Only Service (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-UCW7-C4200SFF UCW7 Yes UCS HW 24X7X4OS
CON-UCWD7-C4200SFF UCWD7 Yes UCS HW+DR 24X7X4OS*
CON-UCW5-C4200SFF UCW5 Yes UCS HW 8X5XNBDOS
CON-UCWD5-C4200SFF UCWD5 Yes UCS HW+DR 8X5XNBDOS*
*Includes Drive Retention (see below for description)
Table 29
Partner Support Service for UCS
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:
■ Expand their service portfolios to support the most complex network environments
■ Lower delivery costs
■ Deliver services that increase customer loyalty
PSS options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their practice.
PSS is available to all Cisco PSS partners.
The two Partner Unified Computing Support Options include:
■ Partner Support Service for UCS
■ Partner Support Service for UCS Hardware Only
PSS for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.You can choose a desired service listed in Table 30.
Table 30 PSS for UCS (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-PSJ8-C4200SFF PSJ8 Yes UCS PSS 24X7X2 OS
CON-PSJ7-C4200SFF PSJ7 Yes UCS PSS 24X7X4 OS
CON-PSJD7-C4200SFF PSJD7 Yes UCS PSS 24X7X4 DR*
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node45
CONFIGURING the SERVER
PSS for UCS Hardware Only
PSS for UCS Hardware Only provides customers with replacement parts in as little as two hours and provides remote access any time to Partner Support professionals who can determine if a return materials authorization (RMA) is required. You can choose a desired service listed in
Table 31 PSS for UCS Hardware Only (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-PSW7-C4200SFF PSW7 Yes UCS W PSS 24X7X4 OS
CON-PSWD7-C4200SFF PSWD7 Yes UCS W PSS 24X7X4 DR*
CON-PSW6-C4200SFF PSW6 Yes UCS W PSS 8X5X4 OS
CON-PSWD6-C4200SFF PSWD6 Yes UCS W PSS 8X5X4 DR*
CON-PSW4-C4200SFF PSW4 No UCS W PL PSS 24X7X2
CON-PSW3-C4200SFF PSW3 No UCS W PL PSS 24X7X4
CON-PSW2-C4200SFF PSW2 No UCS W PL PSS 8X5X4
*Includes Drive Retention (see below for description)
Table 31
Unified Computing Combined Support Service
Combined Services makes it easier to purchase and manage required services under one contract. SNTC services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:
■ Optimize the uptime, performance, and efficiency of your UCS
■ Protect your vital business applications by rapidly identifying and addressing issues
■ Strengthen in-house expertise through knowledge transfer and mentoring
CON-PSJ6-C4200SFF PSJ6 Yes UCS PSS 8X5X4 OS
CON-PSJD6-C4200SFF PSJD6 Yes UCS PSS 8X5X4 DR*
CON-PSJ4-C4200SFF PSJ4 No UCS SUPP PSS 24X7X2
CON-PSJ3-C4200SFF PSJ3 No UCS SUPP PSS 24X7X4
CON-PSJ2-C4200SFF PSJ2 No UCS SUPP PSS 8X5X4
CON-PSJ1-C4200SFF PSJ1 No UCS SUPP PSS 8X5XNBD
*Includes Drive Retention (see below for description)
Table 30 PSS for UCS (PID UCSC-C4200-SFF)
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 46
CONFIGURING the SERVER
■ Improve operational efficiency by allowing UCS experts to augment your internal staff resources
■ Enhance business agility by diagnosing potential issues before they affect your operations,
You can choose a desired service listed in
Table 32 Combined Support Service for UCS (PID UCSC-C4200-SFF)
Service SKU Service Level GSP On Site? Description
CON-NCF2P-C4200SFF NCF2P Yes CMB SVC 24X7X2OS
CON-NCF4P-C4200SFF NCF4P Yes CMB SVC 24X7X4OS
CON-NCF4S-C4200SFF NCF4S Yes CMB SVC 8X5X4OS
CON-NCFCS-C4200SFF NCFCS Yes CMB SVC 8X5XNBDOS
CON-NCF2-C4200SFF NCF2 No CMB SVC 24X7X2
CON-NCFP-C4200SFF NCFP No CMB SVC 24X7X4
CON-NCFE-C4200SFF NCFE No CMB SVC 8X5X4
CON-NCFT-C4200SFF NCFT No CMB SVC 8X5XNBD
CON-NCFW-C4200SFF NCFW No CMB SVC SW
Table 32.
UCS Drive Retention Service
With the Cisco Unified Computing Drive Retention Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive.
Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The Drive Retention service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in the above tables (where available)
NOTE: Cisco does not offer a certified drive destruction service as part of this service.
Local Language Technical Support for UCS
Where available, and subject to an additional fee, local language support for calls on all assigned severity levels may be available for specific product(s) – see tables above.
For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node47
OPTIONAL STEP - ORDER RACK(s)
OPTIONAL STEP - ORDER RACK(s)The optional R42612 rack is available from Cisco for the C-Series servers, including the C4200 server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 33
Table 33 Racks and Rack Options
Product ID (PID) PID Description
RACK2-UCS Cisco R42612 expansion rack, no side panels. This type of rack is used for multiple-rack deployments.
RACK2-UCS2 Cisco R42612 static (standard) rack, with side panels. This type of rack is used for single-rack and end of row deployments. Side panels are needed for racks at the ends of multiple-rack deployments. For example, when configuring a row of 5 racks, order 1 standard rack plus 4 expansion racks. Apply the side panels from the standard rack to the racks at each end of the row.
RACK-BLANK-001 Blanking panels (qty 12), 1U, plastic, toolless.Recommended to ensure proper airflow. Fill all empty RU spaces in the front of the rack. Because each blanking panel PID includes 12 panels, use the following calculation: 42RU - occupied RU = available RU. Divide available RU by 12 to determine PID order quantity.
RACK-CBLMGT-001 Cable mgt D rings (qty 10), metal.Use the D rings to bundle system cables to ensure proper airflow.
RACK-CBLMGT-003 Brush strip (qty 1), 1 U.The brush strip promotes proper airflow while allowing cables to be passed from the front to the rear of the rack.
RACK-CBLMGT-011 Cable mgt straps (qty 10), Velcro.Use the Velcro straps to bundle system cables to ensure proper airflow.
RACK-FASTEN-001 Mounting screws (qty 100), M6.The rack ships with nuts and screws, but extras may be ordered.
RACK-FASTEN-002 Cage nuts (qty 50), M6.The rack ships with nuts and screws, but extras may be ordered.
RACK2-JOIN-001 Rack joining kit.Use the kit to connect adjacent racks within a row. Order 1 unit less than the number of racks in the row.
RACK2-GRND-001 Cisco R42612 grounding kit
. Racks are shipped separately from the C4200 server.
For more information about the R42612 rack, see DIMM Population Rules, page 54.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 48
OPTIONAL STEP - ORDER PDU
OPTIONAL STEP - ORDER PDUAn optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including the C4200 server. This PDU is available in a zero rack unit (RU) style or horizontal PDU style (see Table 34).
Table 34 Available PDUs
Product ID (PID) Description Plug Country
Zero-RU PDUs
RP208-30M1P-6-36 30 A, single-phase, vertical-mount PDU with 6 C19 and 36 C13 connectors
L6-30P North America
RP208-30M3P-6-30 30 A, three-phase, vertical-mount PDU with 6 C19 and 30 C13 connectors
L15-30P North America
RP208-60M3P-12-9 60 A, three-phase, vertical-mount PDU with 12 C19 and 9 C13 connectors
IEC60309
460P9
North America
RP230-32M1P-6-36 32 A, single-phase, button-mount (rear and sides) PDU with 6 C19 and 36 C13 connectors
IEC60309
332P6
International
RP230-32M3P-12-12 32 A, single-phase, button-mount (rear and sides) PDU with 12 C19 and 12 C13 connectors
IEC60309
532P6
International
Horizontal PDUs (occupy RU space)
RP208-30M1P-4-8(1 RU space)
30 A, single-phase, horizontal-mount PDU with 4 C19 and 8 C13 connectors
L6-30P North America
RP208-60M3P-12(2 RU spaces)
48 A, three-phase, horizontal-mount PDU with 12 C19 connectors
L15-30P North America
For more information about the PDU, see PDUs, page 59.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node49
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
CHASSIS
An internal view of the Cisco UCS C4200 rack server chassis with the top cover removed is shown in Figure 6.
Figure 6 Cisco UCS C4200 With Top Cover Off
1 Fan module fault LEDs on fan tray (one LED for each fan module)
■ Green-Fan is OK.
■ Amber-Fan has a fault or is not fully seated
3064
74
1
Fan 1
Fan 2
Fan 3
Fan 4
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 50
SUPPLEMENTAL MATERIAL
BLOCK DIAGRAM
Figure 7 UCS C125 M5 Block Diagram
LP
C
PC
Iex1
US
B2.
0 x
1
External USB 3.0
xGMI (x64)
Channel A
Channel H
DDR III iMC
iBMCPilot4COM PORT
Video
ZEN
ACT2
MGMT Enet
FLASHBIOS A
SPI
DDR4
MISC Logic
CPLD &PSOC
PCIe Gen3 x8
RGMII
RMII( NCSI)
MDI( NCSI)
10/100/1000 LAN
Marvell88E6178
Riser 2
16MB
TPM 1.2CONN
FLASHEXT 0
FLASHEXT 1
PCIe Gen3 x16
SATA x6 USB 3. 0 x 1
PCIe Gen3 x4 / SATA x2
FLASHBIOS B
16MBa/b
sw
itch
DDR4R/LR DIMMS
SPI
MDI
I2C
BOOTFLASH32MB
SPI
NANDFLASH
USB 3. 0 x 1
OCPModule
Riser 1
PCIe Gen3 x16 MDI( NCSI)
M.2 MMC
NAND
POWER Button
ID Loc. Button/LED
256MB512MB
BroadcomBCM5221A
RMII MDI (to CMC)
Health Status LED
μSDSD
USB HUBCY7C65634
USB 2.0 x1
KVM
USB 2.0 x1
DDR III iMC
ZEN
Channel A
Channel H
DDR4R/LR DIMMS
PCIe Gen3 x16
L Hi- Density CONN
NVMe
SATA/SAS x6
SATA/SAS x6
R Hi- Density CONN
Cable fromRiser1 or RAID card
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node51
SUPPLEMENTAL MATERIAL
CPUs and DIMMs
The following figure shows the CPU and DIMM socket placement on the C125 M5 motherboard.
■ Each server node has 16 DIMM sockets total (8 for each CPU).
■ DIMM sockets are organized as one DIMM per channel.
Figure 8 C125 M5 Compute Node Internal Component Locations
3064
55
PCIe 2
1 3 5 7 92 4 6 108
CPU 2
DIMM H2DIMM G2DIMM F2DIMM E2
DIMM A2DIMM B2DIMM C2DIMM D2
DIMM D1DIMM C1DIMM B1DIMM A1
DIMM E1DIMM F1DIMM G1DIMM H1
CPU 1
PCIe 1
1 DIMM sockets (each CPU supports 8 sockets, 16 total)
6 Micro-SD card socket on server board
2 AMD EPYC 7001 (Naples) or 2 AMD EPYC 7002 (Rome) series CPUs and heatsinks (one or two)
The front and rear CPUs use different heatsinks
7 OCP adapter card socket A
OCP adapter cards that require a x8 lane plug into only socket B. OCP cards that require a x16 lane plug in to both sockets A and B
3 Trusted platforms module (TPM) location on server board
8 OCP adapter card socket B
OCP adapter cards that require a x8 lane plug into only socket B. OCP cards that require a x16 lane plug in to both sockets A and B
4 Real-time clock (RTC) battery CR2032 horizontal socket location on server board
9 Socket for PCIe riser 2/PCIe slot 2 (riser not shown in this view)
Riser 2 plugs into a board socket to provide one horizontal PCIe slot (half-height half length, x16 slot)
5 Mini-storage module socket on server board
supports either an SD card carrier with two slots for SD cards, or an M.2 SSD carrier with two slots for M.2 SATA SSDs
10 Socket for PCIe riser 1/PCIe slot 1 (riser not shown in this view)
Riser 1 plugs into this socket to provide one horizontal PCIe slot (half-height half length, x8 slot)
This is the required slot for a SAS RAID controller. The controller supports the six front-loading drives in the chassis that correspond to the node’s position (group 1, 2, 3, or 4)
Riser 1 also includes one x8 slimline connector for pass-through (JBOD) SATA drive control
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 52
SUPPLEMENTAL MATERIAL
DIMM Sockets
The following figure shows the position of the DIMM sockets and how they are labeled on a C125 M5 motherboard. Each DIMM channel consist of one lettered slot (for example, CPU1 A1, B1, C1, or CPU2 A2, B2, C2, etc) for each CPU.
Figure 9 shows the memory slot physically placement.
Figure 9 DIMM and CPU Numbering
4259
87
CPU 2
DIMM H2DIMM G2
DIMM F2
DIMM E2
DIMM A2
DIMM B2
DIMM C2
DIMM D2
DIMM D1
DIMM C1
DIMM B1
DIMM A1
DIMM E1
DIMM F1
DIMM G1
DIMM H1
CPU 1
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node53
SUPPLEMENTAL MATERIAL
Memory Population Rules
■ For optimal performance, spread DIMMs evenly across both CPUs and all channels. Populate the DIMM slots of each CPU identically.
■ For optimal performance, populate DIMMs in the order shown in the following table, depending on the number of DIMMs per CPU.
NOTE: The table below lists recommended configurations.
DIMM Population Rules
AMD EPYC™ processors are designed with an industry leading eight channels of DDR4 memory per processor. With more memory channels, applications will have fewer memory bottlenecks, and better performance for memory bound workloads. Though EPYC™ CPUs do not require a specific loading order for memory DIMMs, its advised to observe the following recommended population guidelines to obtain best performance:
Though a CPU can be populated with a single DIMM as a minimum configuration
■ Full memory bandwidth requires one DIMM per channel (A-H) be populated to obtain best performance with bandwidth sensitive workloads
■ At least one DIMM populated for each channel pair in the system (A,C,E,G) is minimally recommended for Naples.
■ It is recommended to populate the memory in channel pairs for Rome. Both the channels in a channel pair should have the same total memory capacity.
■ Four DIMM configuration (C,D,G,H) is minimally recommended for Rome (Conditionally Recommended only with EPYC processors that have 32 cores or less).
■ In a dual CPU configuration, always balance memory capacity between them as described in Table 35
Figure 10 Memory Organization
DIMM0A
DIMM0B
DIMM0C
DIMM0D
DIMM0
DIMM0
DIMM0
DIMM0
E
F
G
H
DDR4 Speeds with 1 DIMM Per channel Populated SR/DR RDIMM and RDIMM: 2666 MHz
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 54
SUPPLEMENTAL MATERIAL
Table 35 DIMM Population Order
Number of DIMMs Per CPU
CPU 1 Slots(In a single-CPU node, populate only
these slots)CPU 2 Slots
CDGH
1 A1 A2
2 A1, E1 A2, E2
3 A1, E1, C1 A2, E2, C2
4 A1, E1, C1, G1 A2, E2, C2, G2
5 A1, E1, C1, G1, B1 A2, E2, C2, G2, B2
6 A1, E1, C1, G1, B1, F1 A2, E2, C2, G2, B2, F2
7 A1, E1, C1, G1, B1, F1, D1 A2, E2, C2, G2, B2, F2, D2
8 A1, E1, C1, G1, B1, F1, D1, H1 A2, E2, C2, G2, B2, F2, D2, H2
Rome (AMD 7002 CPUs): DIMM Population order
Number of DIMMs per CPU
CPU 1 Slots (In a single-CPU node, populate only
these slots)CPU 2 slots
1 C1 C2
2 C1, D1 C2, D2
3 C1, D1, G1 C2, D2, G2
4 C1, D1, G1, H1 C2, D2, G2, H2
5 C1, D1, G1, H1, A1 C2, D2, G2, H2, A2
6 C1, D1, G1, H1, A1, B1 C2, D2, G2, H2, A2, B2
7 C1, D1, G1, H1, A1, B1, E1 C2, D2, G2, H2, A2, B2, E2
8 C1, D1, G1, H1, A1, B1, E1, F1 C2, D2, G2, H2, A2, B2, E2, F2
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node55
SUPPLEMENTAL MATERIAL
Upgrade and Servicing-Related Parts
This section lists the upgrade and servicing-related parts you may need during the life of your server. Some of these parts are configured with every server, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See Table 36
Table 36 Upgrade and Servicing-related Parts for Cisco UCS C4200 Server
Spare Product ID (PID) Descriptions
Base Chassis
UCSC-C4200-SFF= Cisco UCS C4200 Base Chassis FRU Spare
UCSC-BBLKD-S2= Cisco UCS C4200 C-Series M5 SFF drive blanking panel spare
UCSC-NBLKD-C4200= Cisco UCS C4200 Node Blank spare
UCSC-BZL-C240M5= Cisco UCS C4200 Security Bezel for 2U M5 servers spare
UCSC-FAN-C4200= Cisco UCS C4200 Fan Module (one) spare
UCSC-PSU3-2400W= Cisco UCS C4200 2400W AC power supply spare
UCSC-HS-C125= Cisco UCS C125 M5 Heat sink for UCS C125 Front CPU spare
UCSC-HS2-C125= Cisco UCS C125 M5 Heat sink for UCS C125 Rear CPU
UCS-CPU-TIM= Cisco UCS C125 M5 Single CPU thermal interface material syringe for M5 server HS seal
UCSX-HSCK= Cisco UCS C125 M5 UCS Processor Heat Sink Cleaning Kit For Replacement of CPU
UCSC-SATA-C125= Cisco UCS C125 M5 SATA Cable for Riser 1A
UCSC-SCAP-C125= Cisco UCS C125 M5 SAS3 SuperCap Cable
UCS-MSTOR-SD= Cisco UCS C125 M5 Mini Storage Carrier for SD (holds up to 2)
UCS-MSTOR-M2= Cisco UCS C125 M5 Mini Storage Carrier for M.2 SATA/NVME (holds up to 2)
UCSC-OCP-1025G= UCS C125 OCP 10G/25G SFP 28 adapter panel
UCSC-OCP-100G= UCS C125 OCP 100G QSFP 28 adapter panel
NOTE: The Node Blanking panel (UCSC-C4200-BLKP) must be installed if you remove a node from the Cisco UCS C4200 chassis. This panel is required to maintain proper system temperatures at safe operating levels, and to keep dust away from system components.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 56
SUPPLEMENTAL MATERIAL
RACKS
The Cisco R42612 rack (see Figure 11 on page 58) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment:
■ Cisco UCS B-Series servers and fabric interconnects
■ Cisco UCS C-Series and select Nexus switches
■ Cisco UCS S-Series
The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 37.
Table 37 R42612 Specifications
Cisco R42612 RackStandard (Static with side panels)
Expansion (Static without Side Panels)
Dimensions (H x W x D)
79.25 x 23.50 x 49.84 in.(2013 x 597 x 1266 mm)
79.25 x 23.50 x 49.84 in.(2013 x 597 x 1266 mm)
Dimensions (H x W x D)
with packaging
84.25 x 32 x 54.84 in.(2140 x 813 x 1393 mm)
84.25 x 32 x 54.84 in.(2140 x 813 x 1393 mm)
Distance from front mounting rail to rear mounting rail
29.19 in. (741.5 mm) 29.19 in. (741.5 mm)
Weight 339.51 lb (154 kg) 264.55 lb (120 kg)
Weight with packaging
410.06 lb (186 kg) 335.10 lb (152 kg)
Side panels included Yes No
Equipment mounting capacity
42 RU 42 RU
Static load capacity 2700 lb (1224.7 kg) 2700 lb (1224.7 kg)
Dynamic load capacity
N/A N/A
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node57
SUPPLEMENTAL MATERIAL
Figure 11 Cisco R42612 Rack
Front View Rear View
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 58
SUPPLEMENTAL MATERIAL
PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.
Cisco RP Series PDU models distribute power to up to 42 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
The C-series severs accept the zero-rack-unit (0RU) or horizontal PDU. See Figure 12 for one example of a zero rack unit PDU.
Figure 12 RP208-30M1P-6-36 PDU
1 = Ground
2 = 20 A circuit breakers
3 = IEC 60320 C13 outlets
4 = EC 60320 C19 outlets
5 = NEMA L6-30P plug
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node59
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 38 Cisco UCS C4200 Dimensions and Weight
Parameter Value
Height 3.4 in (87.2 mm)
Width 16.9 in (429.3 mm)
Depth 32.60 in (827.6 mm)
Weight (maximum configuration without rail kit) 95.8 lbs (43.5 kg)
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 60
TECHNICAL SPECIFICATIONS
Power Specifications
The server is available with dual 2400 W (AC) power supplies. The power supply specifications is listed in Table 39.
Table 39 Cisco UCS C4200 2400 W (AC) Power Supply Specifications
Description Specification
AC Input Voltage Nominal range: 200–240 VAC
(Range: 180–264 VAC)
AC Input Frequency Nominal range: 50 to 60Hz
(Range: 47–63 Hz)
Maximum AC Input current 16 A at 200 VAC
Maximum inrush current 35 A at 35° C
Maximum output power per PSU 2400 W at 200–240 VAC
Power supply output voltage 12 VDC
Power supply standby voltage 12 VDC
Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum certified)
Form factor RSP2
Input connector IEC60320 C20
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
http://ucspowercalc.cisco.com.
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node61
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the Cisco UCS C4200 are listed in Table 40.
Table 40 Cisco UCS C4200 Environmental Specifications
Parameter Minimum
Temperature, Operating 41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level.
Temperature, non-operating
(when the server is stored or transported)
–40 to 149°F (–40 to 65°C)
Humidity (RH), operating 10 to 90%
Humidity (RH), non-operating
(when the server is stored or transported)
5 to 93%
Altitude, operating 0 to 10,000 feet
Altitude, non-operating
(when the server is stored or transported)
0 to 40,000 feet
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
5.5
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
40
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 62
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for The Cisco UCS C4200 are listed in Table 41.
Table 41 Regulatory Compliance Requirements
Parameter Description
Regulatory Compliance Products should comply with CE Markings per directives 2014/30/EU and 2014/35/EU
Safety UL 60950-1 Second EditionCAN/CSA-C22.2 No. 60950-1 Second Edition EN 60950-1 Second EditionIEC 60950-1 Second Edition AS/NZS 60950-1GB4943 2001
EMC - Emissions 47CFR Part 15 (CFR 47) Class A AS/NZS CISPR32Class A CISPR32 Class A EN55032Class A ICES003 Class A VCCIClass A EN61000-3-2 EN61000-3-3 KN32Class A CNS13438 Class A
EMC - Immunity EN55024CISPR24 EN300386 KN35
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node63
DISCONTINUED EOL PRODUCTS
unifitice-c
unifitice-c
unifitice-c
unifitice-c
unifitice-c
unifitice-c
unifitice-c
unifitice-c
DISCONTINUED EOL PRODUCTSBelow is the list of parts were previously available for this product and are no longer sold. Please refer to the EOL Bulletin Links via the Table 42 below to determine if still supported.
Table 42 EOL Products
EOS option PID Description EOL bulletin link
Microsoft Windows serverMSWS-16-ST16C Windows Server 2016 Standard (16
Cores/2 VMs)https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-ST24C Windows Server 2016 Standard (24 Cores/2 VMs)
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-ST16C-NS Windows Server 2016 Standard (16 Cores/2 VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-ST24C-NS Windows Server 2016 Standard (24 Cores/2 VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-DC16C Windows Server 2016 Data Center (16 Cores/Unlimited VMs)
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-DC24C Windows Server 2016 Data Center (24 Cores/Unlimited VMs)
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-DC16C-NS Windows Server 2016 DC (16 Cores/Unlim VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
MSWS-16-DC24C-NS Windows Server 2016 DC (24 Cores/Unlim VMs) - No Cisco SVC
https://www.cisco.com/c/en/us/products/servers-ed-computing/ucs-c-series-rack-servers/eos-eol-no51-743145.html
Cisco UCS C4200 Series Rack Server Chassis with UCS C125 M5 Rack Server Node 64